Redline. Comfort functions. Surge Arresters. SurgeGuard. Functions. Applications. Standards. Features. Marking. plug-in

Similar documents
SURGE PROTECTIVE DEVICES

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

Telecommunication Line Protectors

wietap wietap Overvoltage Protection Tensions running high

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Power surges can also be generated by equipment in your facility such as:

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

38 Series - Relay interface modules A

Surge Protection for Photovoltaic Systems

R.C.C.B. s two-pole LEXIC

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB - Pôle Foudre Soulé & Hélita OVR PLUS N1 40

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Safety automation solutions

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

49 Series - Relay interface modules A. Features

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Main catalog. System pro M compact Surge and lightning protection solutions with QuickSafe technology

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

38 Series - Relay interface modules A

CATALOGUE SURGE PROTECTION LOW VOLTAGE

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

48 SERIES Relay interface modules 10 A

15 Series - Electronic step relay and dimmer. Features SERIE

Three-phase monitoring relay CM-PFE

ELEMKO reserves the right to modify, add or remove any information included in this catalogue, if necessary. Every updated version of the catalogue

Electronic overload relay EF19 and EF45

RY2 miniature industrial relays

White paper. ABB solutions for switching and protection of low speed wind turbines

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants

MasterINTERFACE 39 Series - Relay interface modules

Type: DILM9 10(24VDC) Article No.:

Unified requirements for systems with voltages above 1 kv up to 15 kv

Surge Protection. Electrical Installations. Photovoltaic. Telecom. Data. Radiocommunication

ABB Inc. April 19, 2011 Slide 1

Energy Management Energy Meter Type EM23 DIN

DEHNshield Application-optimised multipole combined lightning current and surge arrester

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic overload relay EF65, EF96 and EF146

Type: DILM32 10(24V50HZ) Article No.:

Breaking and protection devices

MasterINTERFACE 39 Series - Relay interface modules

CUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH _0_000

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

RC NETWORKS SALES GUIDE

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

Type: DILM50(230V50HZ,240V60HZ) Article No.:

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Relés e Contatores de Estado Sólido SIRIUS

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

Electro-pneumatic control valves

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

The complete range of consumer switchboards and switchgear

Rack mounted telephone- and leased line modem for industrial applications

Bulletin 150 SMC Flex Smart Motor Controller Specifications

40 Series - Miniature PCB/Plug-in relays A. Features

Class I surge protection with sparkover gaps

Telephone- and leased line modem for industrial applications TD-36

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Nexus Technology Review -- Exhibit A

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

80 Series - Modular timers 16 A. Features

Intersection Preassembled 19-inch Rack

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Photovoltaic Solar Energy Unit EESFB

Surge protection for emergency alarm systems

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

ABB solutions for photovoltaics Protection and other modular devices

Thermistor motor protection

A series of technology briefs spanning Tyco Electronics product portfolio

E-STOP relays, safety gate monitors

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Technical Data. back-up time in minutes 100% load % load

How To Use The Vacon 0 Machinery

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

ST Series POWER SUPPLIES USER INSTRUCTIONS

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Industrial VRS Magnetic Speed Sensors

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Technical catalogue. Modular DIN rail components Installation contactors

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Preventa Machine Safety Products

Electrical Network Management System

Report On Surge Protection & Voltage Fluctuation

Product Information Sheet UH28CS-12kV Hi Pot Tester

TISP9110LDM Overvoltage Protector

Surgelogic Surge Protection Device EMA, EBA, and HWA Series

Surgelogic Surge Protective Device (SPD)

Transcription:

Surge rresters Surgeuard omfort functions unctions Protection of an electrical installation and all electrical and electronic devices connected to this installation against destructive surges. Such voltage surges can be generated by lightning induced currents, by network polluting devices (such a motors, frequency converters, dimmers, etc..) and by power supply networks switching operations. Standards I 61643-I I 61643-11/N 61643-11 IN V 0675-6 N 61-740 S 6651 Marking plug-in pplications Surge arresters cover the protection of home appliances (TV, Hifi, VR, laundry machine, dishwasher...), commercial building equipment (computer, data networks, intrusion and alarm systems, access control and building automation systems), but also industrial equiment (PL, instrumentation, medical apparatus, monitoring devices) and even the protection of entire offshore drilling platforms. eatures The line of surge arresters includes a full range of compact protectors for installation on IN rail. The devices are especially designed to provide complete and effective protection against surges, protecting equipment and property connected to the low voltage network. The range of surge arresters includes: - lass I limp = 100k (monoblock) - lass I+II limp = 12.5k and limp = 25k (plug-in) - lass I+II limp = 7.5k and limp = 15k (monoblock) in 10/350ms waveform - lass II with different discharge capacities: 15k, 20k, 40k in 8/20ms waveform - lass II for photovoltaic applications, communication and TV lines are also available. The most suitable value will be selected according to the type of installation, premises and equipments to be protected. NW plug-in ranges in lass I+II, lass II and for photovoltaic application in uni- and multipole format. Several different formats one pole, single phase, two phase and three phases are available for all types of electrical net systems: TT, TN-S, TN-, IT. dditionally, dedicated versions for temporary overvoltage (TOV) are included in the offer. TOV is a voltage peak of hundreds of volts for an indeterminate period due to the unbalance of the network (normally caused by neutral fault). The Tele OV devices follow the new uropean standard N 50550. 1

Parameters Impulse current (Iimp) This is the peak current that the surge arrester can withstand without failing. The waveform of the applied current is normalised as 10/350μs, used in lass I devices. Maximum discharge current (Imax) This is the peak current that the surge arrester can withstand in a single pulse without failing. The waveform of the applied current is normalised as, used in lass II devices. Nominal discharge current (In) This is the current that the surge protection device is capable of shunting to ground at least 20 times without failing. Level of protection (Up) This is the parameter that characterises the action of the protection device against surges by limiting the voltage between its terminals. It must be less than the surge withstand capacity given by the category of the equipment to be protected. However, if the protector is far from the equipment to be protected it may be necessary to use additional protectors. Surgeuard Maximum continuous operating voltage Umax (Uc) This is the maximum or voltage which may be continuously applied to the terminals of the surge arrester. Performance nergy impulse wave S LOK I S LOK I&II SP I+II SP II SPV I+II SPV II S LOK II S LOK II photovoltaic photovoltaic single phase multi-phase 10/350μs 10/350μs & 10/350μs & 10/350μs & Response time <100ns <25ns <25ns <25ns <25ns <25ns <25ns <25ns Thermal fuse no yes yes yes yes yes yes yes Thermal fuse healty indication no yes yes yes yes yes yes yes Nominal voltage 230V or 400V 230V or 400V 230V or 400V 230V or 400V 600V or 1000V 600V or 1000V 230V or 400V 230V or 400V requency 50/60Hz 50/60Hz 50/60Hz 50/60Hz - - 50/60Hz 50/60Hz Usable in networks TT, TN-S, TN-, IT TT, TN-S, TN-, IT TT, TN-S, TN-, IT TT, TN-S, TN-, IT TT, TN-S, TN-, IT TT, TN-S, TN-, IT Operating temperature -40º+80º -40º...+80º -40º...+80º -40º...+80º -40º +80º -40º...+80º -40º...+80º -40º...+80º Screws Pozidriv 3 Pozidriv 3 Pozidriv 3 Pozidriv 3 Pozidriv 3 Pozidriv 3 Pozidriv 3 Pozidriv 3 Terminal capacity: min 16mm² 6mm² 10mm² 6mm² 10mm² 6mm² 6mm² 6mm² max (flexible/grid) 35/50mm² 25/35mm² 25/35mm² 25/35mm² 25/35mm² 25/35mm² 25/35mm² 25/35mm² onnection scheme Tele OV (continuous overvoltage protection) 2P TOV protection 4P TOV protection TL OV-230 TL OV-400 Shunt Trip TL L Shunt Trip TL L 2P M N L1 L2 L3 4P M L N L N N L1 L2 L3 2

Surgeuard - Surge arresters - lass I+II/+ Single phase PLU-IN Iimp Imax In Up Up Up Umax No. uxiliary No. of at. No. Ref. No. Pack TT, TN-S, (L-N) (N-P) (Uc) of poles contact modules TN-, IT system 25k 100k 25k 1500V - - 275V 1P - 2 SP1 I+II 25/230 660125 1 25k 100k 25k 1500V - - 275V 1P 1O 2 SP1 I+II 25/230 660127 1 25k 100k 25k 2000V - - 440V 1P - 2 SP1 I+II 25/400 660126 1 25k 100k 25k 2000V - - 440V 1P 1O 2 SP1 I+II 25/400 660128 1 omfort functions Multi-phase PLU-IN 12.5k 65k 20k 1300V - - 275V 1P - 1 SP1 I+II 12.5/230 660131 1 12.5k 65k 20k 1300V - - 275V 1P 1O 1 SP1 I+II 12.5/230 660135 1 12.5k 65k 20k 1800V - - 440V 1P - 1 SP1 I+II 12.5/400 660132 1 12.5k 65k 20k 1800V - - 440V 1P 1O 1 SP1 I+II 12.5/400 660136 1 Neutral-earth SP's for TT systems 100k 100k 50k 1500V - - 255V 1P - 2 SP1 I+II 100N 660391 1 50k 65k 50k 1500V - - 255V 1P - 1 SP1 I+II 50N 660130 1 25k 65k 25k 1500V - - 255V 1P - 1 SP1 I+II 25N 660138 1 TT system 12.5k 65k 20k - 1300V 1500V 275V 2P - 2 SP2 I+II 12.5 TT 660139 1 12.5k 65k 20k - 1300V 1500V 275V 2P 1O 2 SP2 I+II 12.5 TT 660140 1 12.5k 65k 20k - 1300V 1500V 275V 4P - 4 SP4 I+II 12.5 TT 660150 1 12.5k 65k 20k - 1300V 1500V 275V 4P 1O 4 SP4 I+II 12.5 TT 660151 1 TN-S system 12.5k 65k 20k - 1300V - 275V 2P - 2 SP2 I+II 12.5 TNS 660143 1 12.5k 65k 20k - 1300V - 275V 2P 1O 2 SP2 I+II 12.5 TNS 660144 1 12.5k 65k 20k - 1300V - 275V 4P - 4 SP4 I+II 12.5 TNS 660152 1 12.5k 65k 20k - 1300V - 275V 4P 1O 4 SP4 I+II 12.5 TNS 660156 1 TN- system 12.5k 65k 20k - 1300V - 275V 3P - 3 SP3 I+II 12.5 TN 660147 1 12.5k 65k 20k - 1300V - 275V 3P 1O 3 SP3 I+II 12.5 TN 660148 1 Replacement modules for lass I+II/+ Iimp Imax In Up Up Up Umax No. uxiliary No. of at. No. Ref. No. Pack (L-N) (N-P) (Uc) of poles contact modules 25k 100k 25k 1500V - - 275V 1P - 2 SM I+II 25/230 660199 1 25k 100k 25k 2000V - - 440V 1P - 2 SM I+II 25/400 660257 1 12.5k 65k 20k 1300V - - 275V 1P - 1 SM I+II 12.5/230 660294 1 12.5k 65k 20k 1800V - - 440V 1P - 1 SM I+II 12.5/400 660295 1 Neutral-earth replacement modules for SPx I+II N 100k 100k 50k 1500V - - 255V 1P - 2 SM I+II 100N 660393 1 50k 65k 50k 1500V - - 255V 1P - 1 SM I+II 50N 660274 1 25k 65k 25k 1500V - - 255V 1P - 1 SM I+II 25N 660296 1 3

Surgeuard - Surge arresters - lass II/ lass II protectors are the most frequently used because they offer high protection and are compatible with most equipments. Single phase PLU-IN ( Imax In Up Up Up Umax No. uxiliary No. of at. No. Ref. No. Pack TT, TN-S, (L-N) (N-P) (Uc) of poles contact modules TN-, IT system 40k 20k - 1300V - 275V 1P - 1 SP1 II 40/230 660158 1 40k 20k - 1300V - 275V 1P 1O 1 SP1 II 40/230 660160 1 40k 20k - 2000V - 440V 1P - 1 SP1 II 40/400 660159 1 40k 20k - 2000V - 440V 1P 1O 1 SP1 II 40/400 660162 1 20k 10k - 1400V - 320V 1P - 1 SP1 II 20/230 660164 1 20k 10k - 1400V - 320V 1P 1O 1 SP1 II 20/230 660166 1 20k 10k - 2000V - 440V 1P - 1 SP1 II 20/400 660165 1 20k 10k - 2000V - 440V 1P 1O 1 SP1 II 20/400 660167 1 Multi-phase PLU-IN Neutral-earth SP's for TT systems 40k 20k - - 1500V 265V 1P - 1 SP1 II 40N 660163 1 20k 10k - - 1500V 255V 1P - 1 SP1 II 20N 660169 1 TT system 40k 20k - 1300V 1500V 275V 2P - 2 SP2 II 40/230 TT 660171 1 40k 20k - 1300V 1500V 275V 2P 1O 2 SP2 II 40/230 TT 660172 1 Surgeuard 20k 10k - 1400V 1500V 320V 2P - 2 SP2 II 20/230 TT 660173 1 20k 10k - 1400V 1500V 320V 2P 1O 2 SP2 II 20/230 TT 660174 1 40k 20k - 1300V 1500V 275V 4P - 4 SP4 II 40/400 TT 660183 1 40k 20k - 1300V 1500V 275V 4P 1O 4 SP4 II 40/400 TT 660184 1 20k 10k - 1400V 1500V 320V 4P - 4 SP4 II 20/400 TT 660185 1 20k 10k - 1400V 1500V 320V 4P 1O 4 SP4 II 20/400 TT 660186 1 TN-S system 40k 20k - 1300V - 275V 2P - 2 SP2 II 40/230 TNS 660175 1 40k 20k - 1300V - 275V 2P 1O 2 SP2 II 40/230 TNS 660176 1 20k 10k - 1400V - 320V 2P - 2 SP2 II 20/230 TNS 660177 1 20k 10k - 1400V - 320V 2P 1O 2 SP2 II 20/230 TNS 660178 1 40k 20k - 1300V - 275V 4P - 4 SP4 II 40/400 TNS 660187 1 40k 20k - 1300V - 275V 4P 1O 4 SP4 II 40/400 TNS 660188 1 20k 10k - 1400V - 320V 4P - 4 SP4 II 20/400 TNS 660189 1 20k 10k - 1400V - 320V 4P 1O 4 SP4 II 20/400 TNS 660190 1 TN- system 40k 20k - 1300V - 275V 3P - 3 SP3 II 40/400 TN 660179 1 40k 20k - 1300V - 275V 3P 1O 3 SP3 II 40/400 TN 660180 1 20k 10k - 1400V - 320V 3P - 3 SP3 II 20/400 TN 660181 1 20k 10k - 1400V - 320V 3P 1O 3 SP3 II 20/400 TN 660182 1 Replacement modules for lass II/ Imax In Up Up Up Umax No. uxiliary No. of at. No. Ref. No. Pack or TT, TN-S, (L-N) (N-P) (Uc) of poles contact modules TN-, IT system 40k 20k 1300V - - 275V 1P - 1 SM II 40/230 660373 1 40k 20k 2000V - - 440V 1P - 1 SM II 40/400 660374 1 20k 10k 1400V - - 320V 1P - 1 SM II 20/230 660297 1 20k 10k 2000V - - 440V 1P - 1 SM II 20/400 660298 1 Neutral-earth replacement modules for SPx II N 40k 20k 1500V - - 265V 1P - 1 SM II 40N 660375 1 20k 10k 1500V - - 255V 1P - 1 SM II 20N 660299 1 4

Surgeuard - Surge arresters - lass I/ The surge arresters have the capacity to divert excess energy for low voltage line protection. lass I surge arresters should be installed in areas at high risk from direct lightning strike discharge. Single phase MONOLOK Iimp In Up Up Up Umax No. uxiliary No. of at. No. Ref. No. Pack TT, TN-S (L-N) (N-P) (Uc) of poles contact modules TN-, IT 35k - - 4000V - 255V 1P - 1 S LOK I 35 667470 1 100k - - - 4000V 255V 1P - 1 S LOK I 100 N 667471 1 able throught - - - - - - 1 S LOK I P 667472 1 omfort functions Surgeuard - Surge arresters - lass I+II/+ The surge arrester can operate as a lass I and lass II protection in accordance with the I 61643-11 lass I/ and lass II/ integrated in only one device. Used in main panelboards (incomer of installations) with high risk from direct lightning strike discharge. ecoupling coils not needed Single phase MONOLOK Iimp In Up Up Up Umax No. uxiliary No. of at. No. Ref. No. Pack TT, TN-S lass I/lass II lass II (L-N) (N-P) (Uc) of poles contact modules TN-, IT 15k/100K 30k - 1300V - 275V 1P - 2 S LOK I&II 100 667486 1 30k/100K 60k - - 1500V 275V 1P - 2 S LOK I&II 100N 667487 1 7.5k/65K 20k - 1300V - 275V 1P - 1 S LOK I&II 65 667517 1 12k/65K 20k - - 1500V 275V 1P - 1 S LOK I&II 65N 667518 1 Surgeuard - Surge arresters - lass II/ Single phase MONOLOK Iimp In Up Up Up Umax No. uxiliary No. at. No. Ref. No. Pack TT, TN-S (L-N) (N-P) (Uc) of poles contact modules TN-, IT 15k 5k - 1200V - 275V 1P - 1 S LOK II 15/230 667473 1 15k 5k - 1200V - 275V 1P 1O 1 S LOK II 15/230 667475 1 15k 5k - 1800V - 420V 1P - 1 S LOK II 15/400 667474 1 15k 5k - 1800V - 420V 1P 1O 1 S LOK II 15/400 667476 1 Multi-phase MONOLOK 15k 5k - - 850V 255V 1P - 1 S LOK II 15N 667481 1 40k 15k - 1300V - 275V 1P - 1 S LOK II 40/230 667477 1 40k 15k - 1300V - 275V 1P 1O 1 S LOK II 40/230 667479 1 40k 15k - 1800V - 420V 1P - 1 S LOK II 40/400 667478 1 40k 15k - 1800V - 420V 1P 1O 1 S LOK II 40/400 667480 1 40k 20k - - 1500V 275V 1P - 1 S LOK II 40N 667482 1 ommon and differential mode protection - TT system 15k 5k - 1200V 1500V 275V 2P - 1 S LOK II 15LN 667483 1 15k 5k - 1200V 1500V 275V 2P - 2 S LOK II 15/230 LN 667488 1 40k 15k - 1300V 1500V 275V 2P - 2 S LOK II 40/230 LN 667490 1 15k 5k - 1200V 1500V 440V 4P - 4 S LOK II 15/400 3L+N 667494 1 40k 15k - 1300V 1500V 440V 4P - 4 S LOK II 40/400 3L+N 667496 1 ommon mode protection - TNS system 15k 5k 1200V - - 275V 2P - 2 S LOK II 15/230 LL 667489 1 40k 15k 1300V - - 275V 2P - 2 S LOK II 40/230 LL 667491 1 15k 5k 1200V - - 440V 4P - 4 S LOK II 15/400 4L/N 667495 1 40k 15k 1300V - - 440V 4P - 4 S LOK II 40/400 4L/N 667497 1 40k 15k 1300V - - 440V 4P 1O 4 S LOK II 40/400 4L/N 667498 1 Surge arresters for communication lines and coax cables The protective devices should be installed for sensitive equipment both in home and industries. Telephone, modem, Imax In Up Up Up Umax fg Protection No. of at. No. Ref. No. Pack router, alarm, home (L-N) (N-P) andwidth type modules automation 10k 5k 200V - - 180V 3MHz 1 par 1 S LOK SL 667484 1 Radio frequency 20k 10k 600V - - 230V 3Hz N - S TV 667510 1 signals, TV, cameras, receivers, satelite 5

PLU-IN Surgeuard - Surge arresters - lass I+II for () photovoltaic applications Iimp Imax In Up Umax No. uxiliary No. of at. No. Ref. No. Pack of poles contact modules 12.5k 65k 20k 2600 700Vdc 3P - 3 SPV I+II 12.5/600 660191 1 12.5k 65k 20k 2600 700Vdc 3P 1O 3 SPV I+II 12.5/600 660192 1 12.5k 65k 20k 4000 1170Vdc 3P - 3 SPV I+II 12.5/1000 660193 1 12.5k 65k 20k 4000 1170Vdc 3P 1O 3 SPV I+II 12.5/1000 660194 1 Replacement modules for lass I+II photovoltaic applications 12.5k 65k 20k - 350Vdc 1P - 1 SM I+II 12.5/600PV 660376 1 12.5k 65k 20k - 585Vdc 1P - 1 SM I+II 12.5/1000PV 660377 1 PLU-IN Surgeuard - Surge arresters - lass II for () photovoltaic applications Imax In Up Umax No. uxiliary No. of at. No. Ref. No. Pack of poles contact modules 40k 20k 2600V 700Vdc 3P - 3 SPV II 40/600 660195 1 40k 20k 2600V 700Vdc 3P 1O 3 SPV II 40/600 660196 1 Surgeuard MONOLOK 40k 20k 4000V 1170Vdc 3P - 3 SPV II 40/1000 660197 1 40k 20k 4000V 1170Vdc 3P 1O 3 SPV II 40/1000 660198 1 Replacement modules for lass II photovoltaic applications 40k 20k 1300V 350Vdc 1P - 1 SM II 40/600PV 660378 1 40k 20k 2000V 585Vdc 1P - 1 SM II 40/1000PV 660379 1 Surgeuard - Surge arresters - lass II for () photovoltaic applications 40k 15k 2600V 600Vdc 2P - 2 S PHOT 600V 667508 1 40k 15k 3800V 1000Vdc 2P - 2 S PHOT 1000V 667509 1 Surge arresters for temporary overvoltage protection (TOV) (1) In Ua Tripping time Un No. No. of at. No. Ref. No. Pack L-N (Ua) (400V) of poles modules M's 254V <4s <0.5s 230V 2 1 TL OV 230 667485 1 M's 254V <4s <0.5s 400V 4 2 TL OV 400 667493 1 Insulated ORK type busbars Section escription at. No. Ref. No. Pack 10mm² 2x1P - 90 V-.1.2.80-90 624993 20 10mm² 3x1P - 90 V-.1.3.80-90 644893 20 10mm² 4x1P - 90 V-.1.4.80-90 568106 20 10mm² 8x1P - 90 V-.1.8.80-90 644897 20 (1) onnection scheme Tele OV, see page 2 6

imensional drawings Surge arresters - Surgeuard MONOLOK types S LOK, S LOK SL 70 65 49 S LOK II 15 LN 63,75 58 50,30 omfort functions PLU-IN types 90 22,50 71 65 50 85 20 Replacement modules 71 65 50 90 90 22,50 47 22,50 47 or coax cables (STV) TL OV - Overvoltage protection 60 64 58 50,50 Ø24 26,5 85,50 20,25 7