ABB - Pôle Foudre Soulé & Hélita OVR PLUS N1 40
|
|
|
- Corey Delilah Carson
- 10 years ago
- Views:
Transcription
1 Presentation ABB - OVR PLUS N1 40 ABB France Lightning Protection Group
2 All in one product SPDs with integrated back up protection are a solution that allow to have a complete surge protection design into one product ABB has a range offering both solution to cover different market field Those products are a good solution in order to: Offer to customer a solution that many specialist don t have Offer a good solution for residential or commercial markets
3 Dedicated Applications TT & TNS networks (1 phase + neutral) Residential in high frequency lightning areas keraunic level >25 Commercial buildings with crucial electrical equipments : computer networks, switchboards, inverters
4 Main Advantages Auto-protected With its integrated end of life protection by MCB, no need of additional MCB or fuse. Compact 2 modules only to save space. Easy to install High performance Isc at Un: 15KA In : 20KA Discharge current With Im* 40kA, the OVR PLUS can be installed in high risk areas (keraunic level>25) *: Imax of the MOV Eco-Design & Recycling Innovative internal design: helps to reduce CO2 emissions
5 Main Advantages State Indicator Visual indication: The MCB lever contact indicates the state of the surge arrester S2C-H6R: As option, ABB prom Range auxiliary contact Complete ABB ProM design
6 Operating characteristics Very high flow capacity: Can afford one 40,000A impact (or 20 consecutive impacts of 20,000A) Secure End of Life: association of a bimetal sensor (patented) and an MCB EoL due to overvoltage: progressive warm-up of the varistor recognised by the bimetal sensor which causes the opening of the MCB EoL due to strike: the varistor is placed in short circuit, the MCB opens instantaneously
7 Operating characteristics Greater reliability Due to a brand new technology with no welding in the product : As soon as the internal temperature reaches 100 C the sensor automatically opens the MCB Full protection Common mode neutral/earth (gas spark gap) & differential phase/neutral (varistor) TT & TNS networks (1 phase + neutral)
8 A fully environmental product Reduced environmental impact: To produce the OVR PLUS N1 40, we have followed the Environmental management: life cycle assessment-principle & framework of ISO for the analysis of all phases of the cycle life of the product Compliance with the RoHS rules (2002/96/CE): Lead, mercury, hexavalent chromium, cadmium, PBB or PBDE free Very low consumption <220µA Compact and light (less plastic & metal) No welding => less energy for assembly, less raw material used, more reliable No dangerous material => can be destroyed by crushing
9 Technical data sheet- Electrical features
10 Technical data sheet mechanical features
11 Easy cabling 30m maximum Ph N T Equipment No additionnal fuse or breaker for end of life O,5m maxi
12 State indication Lever position of MCB «ON»: SPD connected Lever position of MCB «OFF»: To connect the SPD, put the lever position on «ON» Lever position of MCB «OFF» and impossible to put «ON»: The SPD is disconnected and you must replace it
13 Marketing Tools Leaflet of OVR PLUS Competitor analyse Technical Article High resolution pictures Data sheet Samples
14
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants
The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants Made for the sun, threatened by atmospheric discharges The importance of surge protective
Main catalog. System pro M compact Surge and lightning protection solutions with QuickSafe technology
Main catalog System pro M compact Surge and lightning protection solutions with QuickSafe technology System pro M compact Surge and lightning protection solutions with QuickSafe technology Presentation
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
CATALOGUE SURGE PROTECTION LOW VOLTAGE
CATALOGUE SURGE PROTECTION LOW VOLTAGE SALTEK, s.r.o. (limited liability company), is a Czech company specialising in the development and manufacture of surge protection devices (SPD). SALTEK offer a wide
SANS 10142-1 : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation
SANS 10142-1 : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation 4 Compliance Proof of Compliance (Sub clause 4.1.1) The SABS safety mark The SABS approved performance mark
wietap wietap Overvoltage Protection Tensions running high
wietap wietap Overvoltage Protection Tensions running high 2 wietap wietap Overvoltage protection Important information on overvoltage The necessity of overvoltage protection on machines and systems as
Redline. Comfort functions. Surge Arresters. SurgeGuard. Functions. Applications. Standards. Features. Marking. plug-in
Surge rresters Surgeuard omfort functions unctions Protection of an electrical installation and all electrical and electronic devices connected to this installation against destructive surges. Such voltage
Surge Protection for Photovoltaic Systems
Surge Protection for Photovoltaic Systems 2 photovoltaic generator disconnection boxes Index Introduction 4 Protection of PV systems 5 Surge Protection Range for PV system 6 Surge Protection Panels for
White paper. ABB solutions for switching and protection of low speed wind turbines
White paper ABB solutions for switching and protection of low speed wind turbines ABB solutions for switching and protection of low speed wind turbines Index 1 Introduction...2 2 Full converter configuration...4
SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A
SURGE PROTECTIVE DEVICES (SPDs) INTEGRATED UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective
DEHNshield Application-optimised multipole combined lightning current and surge arrester
DEHshield Application-optimised multipole Application-optimised prewired combined lightning current based on spark gap technology simply equipped electrical installations with reduced technical requirements
Power surges can also be generated by equipment in your facility such as:
Power Quality Surge Suppressors What is Surge Protection A surge suppressor can be the first and best defense against the instant or gradual destruction of electrical equipment. Compared to the replacement
Product Environmental Profile Step Down Transformers
Product Environmental Profile Step Down Transformers Product overview Step-down transformers are used to convert a higher input voltage (208-200 V) to a lower output voltage (120-100 V). They are used
Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power
App Notes ~ Outdoor Power System Design and Cost Considerations 1 Authors Peter Nystrom President TSi Power Corp. Coordination of Telecommunications Surge Protective Devices in Countries with Unstable
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
Transient and Lightning Protection for the Water Industries
Transient and Lightning Protection for the Water Industries Mike Nager Phoenix Contact [email protected] 5 th ISA Water/Wastewater Automatic Controls Division Symposium (WWAC) August 3-5, Orlando,
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B
SURGE PROTECTIVE DEVICES (SPDs) EXTERNAL SIDEMOUNT UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective
ABB solutions for photovoltaics Protection and other modular devices
ABB solutions for photovoltaics Protection and other modular devices 2 ABB Component supplier for residential and power plant application ABB has been working for many years, as both a manufacturer and
Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
Product Regulatory Compliance Datasheet ediscovery 8200
Product Regulatory Compliance Datasheet ediscovery 8200 TABLE OF CONTENTS I. GLOBAL ENVIRONMENTAL INFORMATION...1 II. SYSTEM DIMENSION AND WEIGHT...1 III. BATTERIES....2 IV. POWER CORDS AND USER DOCUMENTATION.....2
ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors
ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants Installation instructions Contents Key points of installation Before installation Installation Installation check
ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw
Solar inverters ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw ABB s central inverters are extremely scalable, modular-inverter systems that are based on 55kW modular
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
Product Regulatory Compliance Datasheet ediscovery 8100
Date: August 2014 Product Regulatory Compliance Datasheet ediscovery 8100 TABLE OF CONTENTS I. GLOBAL ENVIRONMENTAL INFORMATION...1 II. SYSTEM DIMENSION AND WEIGHT...1 III. BATTERIES....2 IV. POWER CORDS
SD Series. SD Series Rectifiers. EPC Energy & Power Conversion
Rectifiers Microprocessor controlled rectifier technology Fully adjustable float, boost and equalizing charge modes with V/I characteristic Advanced technology for phase control Verylowvoltage ripple and
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Product brochure Multi Functional Switchgear PASS M00 72.5 kv Flexible and compact switchgear solutions for windfarms
Product brochure Multi Functional Switchgear PASS M00 72.5 kv Flexible and compact switchgear solutions for windfarms The future of Wind Farms As offshore wind farms move towards deploying higher capacity
ABB Inc. April 19, 2011 Slide 1
ABB Automation & Power World: April 18-21, 2011 Allen Austin - Solar Segment Manager North America, Low Voltage Products WLP-123-1-CEU Solar applications for low voltage products ABB Inc. April 19, 2011
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Electrical safety and protection devices
Electrical safety and protection devices RCD PROTECTION The easy, economical way to safeguard yourself when working with electricity. RCDs are specifically designed to minimise the risk of a fatal electric
How To Understand The Electrical Power Supply Of A Power Supply System
17 Circuit diagram symbols E 18 CIRCUIT DIAGRAM SYMBOLS electrical network elements three-phase line or cable single-phase line or cable short circuit earth electrode outgoing feeder supply incoming feeder
Connection Cable for LED Driver Board
Connection Cable for LED Driver Board 2CBL03 DATA SHEET DOD-PP-07 (st edition) All information is subject to change without notice. Please confirm the sales representative before starting to design your
Product Regulatory Compliance Datasheet NBU 5330
Product Regulatory Compliance Datasheet NBU 5330 TABLE OF CONTENTS I. GLOBAL ENVIRONMENTAL INFORMATION...1 II. BATTERIES....1 III. POWER CORDS AND USER DOCUMENTATION.....2 IV. DATASHEET RESPONSIBLE PARTY
ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV
1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled
Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications
Product Overview Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications The 2Pro AC family of devices provide integrated overcurrent/overvoltage/ overtemperature
Hong Kong Green Label Scheme Product Environmental Criteria for Copying Machines, Printers, Fax Machines and Multifunctional Devices (GL-006-003)
BACKGROUND Hong Kong Green Label Scheme The Hong Kong Green Label Scheme (HKGLS) is an independent and voluntary scheme, which aims to identify products that are, based on life cycle analysis consideration,
SURGELOGIC TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage
TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage Internal and External Mounted TVSS Retrofit or New Construction Low Let-through Levels High Surge Capacities Internal
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
ELEMKO reserves the right to modify, add or remove any information included in this catalogue, if necessary. Every updated version of the catalogue
' EEMKO reserves the right to modify add or remove any information included in this catalogue if necessary Every updated version of the catalogue automatically cancels all the previous ones Photographs
Product Regulatory Compliance Datasheet BE3600
Product Regulatory Compliance Datasheet BE3600 TABLE OF CONTENTS I. GLOBAL ENVIRONMENTAL INFORMATION...1 II. BATTERIES...1 III. POWER CORDS AND USER DOCUMENTATION.....2 IV. DATASHEET RESPONSIBLE PARTY
Dlp-s & WIRING DEVICES. THE MAXIMUM FReeDOM OF ChOICe. SNAP-ON AND UNIVERSAL TRUNKING FOR high AND LOW CURReNt DIStRIBUtION
Dlp-s & WIRING DEVICES THE MAXIMUM FReeDOM OF ChOICe SNAP-ON AND UNIVERSAL TRUNKING FOR high AND LOW CURReNt DIStRIBUtION the global specialist IN electrical AND DIGItAL BUILDING INFRAStRUCtUReS Be free
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03
PRO370D 65A Mbus MID DIN rail three phase four wire energy meter User manual Version 1.03 1 Safety instructions... 3 2 Foreword... 4 3 CE certificates... 5 4 MID certificate... 7 5 Performance criteria...
ABB central inverters PVS800 100 to 1000 kw
Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002 NEW GAS INSULATED SWITCHGEAR (GIS) FOR ALL MEDIUM VOLTAGE APPLICATIONS H. Fink, ABB Calor Emag Mittelspannungs GmbH; M. Hyrenbach, ABB Calor
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Applications. Remote Display Mounting Kits
June 200 Sheet 105 Surge Protection Products TVSS General Description Clipper Power System Visor Series.1-5 Clipper Power System Visor Series General Description Eaton s Cutler-Hammer leading-edge surge
Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1
Page 1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Divisions 1 Specification sections apply to
CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA
Highlights & Features Reliable design, with expected life of 10 years Compact, rugged design for ease of handling and installation Multiple connections to terminals allowed Designed for Class I Div. 2
Surge Protection. Electrical Installations. Photovoltaic. Telecom. Data. Radiocommunication
9 th e d i t i o n Surge Protection Electrical Installations Photovoltaic Telecom Data Radiocommunication General atalog 9 th edition p. 6 DIN RAIL A POWER SURGE PROTETORS p. 60 P HOTOVOLTAI SURGE PROTETORS
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Environmental Product Declaration www.siemens.com/healthcare
syngo X Workplace Environmental Product Declaration www.siemens.com/healthcare s Progress that is Impressive Ecological Advantages of the syngo X Workplace The syngo X Workplace allows SW-based 3D reconstruction
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
GP2Y0A02YK0F. Distance Measuring Sensor Unit Measuring distance: 20 to 150 cm Analog output type GP2Y0A02YK0F
GP2Y0A02YK0F Distance Measuring Sensor Unit Measuring distance: 20 to 150 cm Analog output type Description GP2Y0A02YK0F is a distance measuring sensor unit, composed of an integrated combination of PSD
Protection catalogue 15
15 Protection catalogue Protection devices MCBs, RCBOs, RCCBs, fuse carriers and surge protection Hager offers a wide range of Modular Protection Devices, such as miniature circuit breakers, auxiliaries
Telecommunication Line Protectors
TN CR 0025 Telecommunication Line s 1.1 The nature of telecom surges The telecom services considered in this report are transported on twisted pair. Each service has two wires, or lines, sometimes called
1 POLE - 5A SLIM POWER RELAY
POWER RELAY POLE - A SLIM POWER RELAY FTR-MY Series RoHS compliant FEATURES Width mm, height mm,(% smaller than NY series) area mm, super slim, low power, compact and light weight.gr. Nominal power: mw
This is a preview - click here to buy the full publication TECHNICAL REPORT
TECHNICAL REPORT IEC TR 62066 First edition 2002-06 Surge overvoltages and surge protection in low-voltage a.c. power systems General basic information Surtensions de choc et protection contre la foudre
New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance
New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance Dennis W. Lenk, Fellow, IEEE Abstract-- This paper examines performance
Lightning current simulation in the laboratory - parameters, procedures and test equipment -
Lightning current simulation in the laboratory - parameters, procedures and test equipment - Dipl.-Ing. J. Schönau, Dr.-Ing. M. Naß, CE-LAB GmbH Prof. Dr.-Ing. F. Berger, Ilmenau University of Technology
Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw
Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges
HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic
HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic Heol fleet tracking system GPS N103 -OBD GPRS FTS Software Internet Main office - Control room Other office The specifications in this document
How To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
A series of technology briefs spanning Tyco Electronics product portfolio
A series of technology briefs spanning Tyco Electronics product portfolio Coordinated Circuit Protection Schemes Help Prevent Overvoltage and Overcurrent Damage Through advances in materials science and
Data Center Integrated solutions
Data Center Integrated solutions PERFORMANCE AND RELIABILITY AT THE HEART OF DATA CENTERS The growing number of business and technical demands placed on data centers today are becoming increasingly critical:
SAMI Microstar (SAMI MM, MD, MS)
1 ABB Oy 18.2.2000 Product Support TLC/Ari Niskanen SAMI Microstar (SAMI MM, MD, MS) Recycling information for drive of type SAMI Microstar Table of contents TABLE OF CONTENTS...1 1. INTRODUCTION...2 2.
AQUACIAT2 HYBRID THE COMPACT DUAL-ENERGY SOLUTION HEAT PUMP & GAS BOILER. Cooling and heating capacities of 45 to 80 kw AVAILABLE 2 ND QUARTER OF 2014
AVAILABLE 2 ND QUARTER OF 2014 HEAT PUMP & GAS BOILER C O M F O R T A I R Q U A L I T Y E N E R G Y O P T I M I S A T I O N AQUACIAT2 HYBRID Cooling and heating capacities of 45 to 80 kw THE COMPACT DUAL-ENERGY
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Indoor / Outdoor Antenna
z300 High Precision NTP Time Server Indoor / Outdoor Antenna High Precision NTP Time Server with PoE (Indoor or Outdoor use) synchronized by GPS Revision 4 ZTI / 1 boulevard d'armor / BP 20254 / 22302
AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE
An Introduction to Transient Voltage Suppression Devices Prepared by: Jim Lepkowski ON Semiconductor APPLICATION NOTE INTRODUCTION Transient Voltage Suppression (TVS) protection devices such as shielded
How can a charging station for electric vehicles be set up simply and safely?
SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,
New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager
New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager 2 1SDC200039B0201 New SACE Emax 2 for UL 1066 Circuit breakers switch power SACE Emax 2 manages it. SACE Emax 2 is the new benchmark of
The following components are common to most cubicles; this example is an ABB HK cubicle.
4.0 CIRCUIT BREAKER CUBICLE Learning Objectives The circuit breaker cubicle is the component of the switchgear that holds the circuit breaker, and the controls and cabling for the distribution system.
Data Assessment for Electrical Surge Protection Devices
Data Assessment for Electrical Surge Protection Devices Phase 1 Final Report Prepared by: Eddie Davis Nick Kooiman Kylash Viswanathan Hughes Associates, Inc. Vancouver, Washington 98660 October 2014 Fire
BLUE RIBBON CORP. BC001 Birdcage Installation Manual
Product Overview: This manual is applicable for the BC001 Birdcage Submersible Level Transmitters. If the product you have has a different prefix part number than listed above please contact the factory
Urban lighting luminaire XMOD RX. Registered models - Design Massimo Sacconi. NERO e GRIGIO per marchi piccoli (ha il filo ingrossato)
Urban lighting luminaire XMOD RX Registered models - Design Massimo Sacconi NERO e GRIGIO per marchi piccoli M OD RX XMOD is part of the XMOD series : a series of LED luminaires for street, urban and architectural
Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.
Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work. Data security is first of all electrical Maximizing security while providing efficiency
Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125
Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC3-12 MC3-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated
Anti-blackout system for grid connected solar installations (Solsafe concept)
Anti-blackout system for grid connected solar installations (Solsafe concept) General description The Solsafe concept is a system which will automatically switch from a grid feeding inverter connected
Protect. Surge Protection for home and small office
Surge ion for home and small office Surge ion When the voltage rises High voltage surge high damage Over 1.7 million lightning flashes were counted in Germany in 2011. The flash frequency was 0.5 to 10
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
China RoHS Directive Legislation Compliance October 2011
China RoHS Directive compliance information: China RoHS Directive Legislation Compliance October 2011 Declaration & Restriction Scope Packaging Differences to EU RoHS First Catalogue China RoHS2 1 RoHS
Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management
Energy Depot GmbH Delivering Solutions for Energy Management PRODUCT AND APPLICATION GUIDE Total Monitoring Solution for PV SOLAR LOGGER & ANALYSIS DC STRING MONITORING Residential Comprehensive Solar
ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen
DC Combiner box and AC solutions. Leadership in circuit protection
DC Combiner box and AC solutions Leadership in circuit protection Eaton and Cooper united. Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability
Communication bridge Xcom-MS User Manual
Communication bridge User Manual Copyright 2011 Studer Innotec SA - V1.0.1 Communication bridge : User Manual V1.0.1 Copyright 2011 Studer Innotec SA About the software This document applies to the software
A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9
110 0V E+ E- VOLT STAB KNEE 47.5Hz OFF 9 SPECIAL 8 KNEE 65Hz 7 OFF KNEE 6 57Hz OFF 7 8 50Hz o 9 0 5 6 1 2 3 4 OFF 1 13% 2 25% 3 OFF 4 13% 5 25% 60Hz FREQ. & L.A.M. CONFIG. This manual concerns the alternator
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
Universal control module for motorized devices
Ref: MOD-0105-N The MOD-0105-N is a universal module for motorized devices, blinds, awnings, curtains, doors, etc.. Allows, with vivimat BUS, the local or remote control of a motorized devices, ensuring