COMMERCIAL ROOFING. Learning Objectives. Commercial Roofing Fundamentals May 2, 2012



Similar documents
CHAPTER 7: Building Systems ROOFING SYSTEMS

Roofing Systems. New Applications / Re-Roofing / Maintenance

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

Best Practices in Roof Design: Sustainable Energy Efficient Reroofing

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE

COMMERCIAL BUILDING APPLICATIONS

FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Durapax Coal Tar BUR Application Guide

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Maintaining Your Roof

Low-slope reroofing guidelines

UL Online Certifications Directory

COMMERCIAL & LOW SLOPED ROOF SPECIALISTS TOTAL NDL SYSTEM MANUFACTURER WARRANTIES

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

EPDM. Roofing systems

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

BUSI 441 Project 1: Reserve Fund Study

Firestone RubberGard The EPDM reference

How To Know If A Reflective Roofmembrane Is More Efficient

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

ROOF ASSEMBLIES CHAPTER 9

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Please read the entire document before purchasing and installing any of these products

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

CRS Sales & Marketing

ANSI/SPRI WD-1 Wind Design Standard Practice for Roofing Assemblies. Table of Contents. 1.0 Introduction Methodology...2

THERMOPLASTIC-POLYOLEFIN ROOFING (TPO) Data Center

The Harold J. Becker Company, Inc.

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

THERMAL AND MOISTURE PROTECTION WATERPROOFING

Building Owners Guide to a Duro-Last System!

HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION

Proven roofing SyStemS

Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

metal Duil~ing manufacturers Association

APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE

Residential Roofing Guide

What to Do About Your Roof and How to Hire a Roofing Contractor

ROOFING CONTRACTORS QUESTIONNAIRE

Solicitation DTFACN-11-R Attachment #9

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

Nominal Life Expectancy for Building Components

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

Roof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, RBA Project No

TARRANT COUNTY DETAIL STANDARDS

BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC.

Proper roof slope and drainage are important to prevent excessive water accumulation

CREEK Technical Services, LLC

DIVISION 7 - THERMAL AND MOISTURE PROTECTION

BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES

ISO Types 1-6: Construction Code Descriptions

Get Rid of Roof Problems for Good. How spray foam roofing can protect your building and make you money

Peel & Seal Self-Stick Roofing Solutions

Laboratory Report P Simulated Wind Uplift Testing of Adhered Single-Ply Roofing Systems in accordance with FM Standard 4470, Appendix C

Firestone SBS Modified Bitumen Roofing System Design and Application Guide

Membrane Roofing. Advances in Membrane Roofing


SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

SECTION THERMOPLASTIC MEMBRANE ROOFING

The existing roof angle change terminations and flashings when sound and intact can be reused.

Roof Systems Overview

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

ROOF INSPECTION & MAINTENANCE

HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION

Quality You Can Trust Since From North America s Largest Roofing Manufacturer

FIRESTONE BUILT-UP ROOFING SYSTEMS APPLICATION GUIDE 3/14/2011

The Building Group First Tuesdays First Saint Paul s Lutheran Church 1301 North LaSalle Street, Chicago, Illinois

ROOF CONSTRUCTION SCIENCE (METCT092)

Class Number June FM Approvals LLC. All rights reserved.

Class Number April FM Approvals LLC. All rights reserved.

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Roof Inspection. Summary Report

Commercial Roof Inspection Form

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

Commercial Roof Management

SECTION PVC SINGLE PLY ROOFING

Roof Inspection. Summary Report

SEAMS SEAMING USING SEAM TAPE

Transcription:

COMMERCIAL ROOFING The Fundamentals Firestone Building Products is a Registered Provider with the American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to CES Records for AIA members. Certificates of Completion for non- AIA members are available upon request. This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods and services will be addressed at the conclusion of this presentation. Learning Objectives Roofing 101 Fundamentals Fundamental review of all types of roofing EPDM systems Thermoplastic systems Asphalt systems System attachment C-CAP/Firestone, Austin, TX 512-282-3611 1

Roofing 101 A Selection Process IS YOUR ROOF AN ASSET OR LIABILITY? The Buzzwords Some common roofing terms: Alligatoring The cracking of the asphalt surface, looks like alligators hide Blistering Air pocket between layers of felt usually caused by trapped water. Bridging When membrane is un-supported at a juncture. Fishmouth opening along side lap of membrane, gives appearance of a fish s mouth. Slope- Direction of the slant of the roofing substrate. (Positive or Negative or Flat) Oil Canning Industry Acronyms AIA American Institute of Architects ANSI American National Standards Institute ARMA Asphalt Roofing Manufacturers Assoc. ASHRAE American Society of Heating, Refrigeration & A-C Engineers ASTM American Society for Testing and Materials CABO Council of American Building Officials CSI Construction Specifications Institute ICC International Code Council IBC International Building Code ERA EPDM Roofing Association NRCA National Roofing Contractors Association PIMA Polyisocyanurate Manufacturers Assoc. RCI Roof Consultants Institute SMACNA Sheet Metal and Air Conditioning Contractors Nat l Assoc. SPRI Single Ply Roofing Institute UL Underwriters Laboratories, Inc. C-CAP/Firestone, Austin, TX 512-282-3611 2

Myriad of Acronyms APAO APP BUR CPA CPE CSPE EIP EPDM PIB PVC SBS TPA TPO Atactic Polyalphaolefin Atactic Polypropylene Built-up Roofing Copolymer Alloy Chlorinated Polyethylene Chlorosolfonate lf Polyethylene l Ethylene Interpolymers Ethylene Propylene Diene Monomer Polyisobutylene Polyvinyl Chloride Styrene Butadiene Styrene Thermoplastic Alloy Thermoplastic Polyolefin Product Acronyms Thermoset Single Ply: EPDM Ethylene Propylene Diene Monomer Thermoplastic Single Ply: PVC Polyvinyl Chloride TPO Thermoplastic Polyolefin Modified Bitumen: APP Atactic Polypropylene SBS Styrene Butadiene Styrene Built-Up Roofing - BUR TWO BASIC TYPES OF ROOFING STEEP ROOFING HIGH SLOPE, DESIGNED TO SHED WATER RAPIDLY SHINGLES, SLATE, THATCH (Pieces) C-CAP/Firestone, Austin, TX 512-282-3611 3

TWO BASIC TYPES OF ROOFING LOW SLOPE ROOFING SOMETIMES CALLED FLAT ROOFING, HAVE TO BE DESIGNED TO MOVE THE WATER OFF SINGLE PLY MEMBRANES AND BITUMEN BASED Prototype -Tampa, FL General Observation Slope HVAC EPDM Condensation Lines Walkway Pads Parapet Gutter C-CAP/Firestone, Austin, TX 512-282-3611 4

Prototype -Tampa, FL General Roof Design Considerations WHAT ARE THE ROOF DESIGN CONSIDERATIONS? Slope HVAC Building Cost Code Gutter EPDM Insurance Location within (FM, IRI) USA (North, South, East, West) Condensation Lines Building Surrounding Use Topography (Public, Private, (Open Walkway Freezer ) City, Pads Coastal, Desert) Roof Loads Structure/Detailing on Parapet Building (Equipment, Wind, Rain Snow ) Slope Shape, of Location Roof (Structural, & Height (Compass Tapered ) Direction) Exterior Maintenance Wall (Roof Design System, (Block, HVAC, Brick, Roof Stucco, Access Tilt-up ) Roof-top Aesthetics Projections (HVAC, Sky Lights Dish ) Wall Contractor Openings Availability (Truck Bay Doors) STEEP BASIC ROOFING DIFFERENCES LOW SLOPE LARGE PANEL SIZES ROOF ON THE INSULATION BOARD STOCK INSULATION WATER DRAINS SLOWLY CAN DESIGN FOR TRAFFIC COMMERCIAL DISCRETE PIECES ROOF DIRECTLY ON DECK LOOSE FLUFFY BOARD STOCK INSULATION UNDER DECK WATER DRAINS RAPIDLY DISCOURAGES TRAFFIC RESIDENTIAL ALL ROOFS MUST: DRAIN TO WORK STEEP ROOFS DRAIN TO THE SIDE LOW SLOPE ROOFS DRAIN OFF THE SIDES OR TO INTERIOR DRAINS REMEMBER - SLOPE GOOD WATER BAD C-CAP/Firestone, Austin, TX 512-282-3611 5

BASIC ROOFING: A SELECTION OF COMPONENTS DECKING TYPES STEEL CONCRETE STRUCTURAL LIGHT WEIGHT WOOD TECTUM (Schools) CEMENTITIOUS WOODFIBER GYPSUM DECK TYPE & CONDITION WILL IMPACT: WEIGHT OF SYSTEM ALLOWABLE TYPE OF AFFIXMENT METHOD WHICH CAN BE USED BALLASTED BALLASTED ADHERED MECHANICALLY ATTACHED FOR MECHANICALLY ATTACHED, REQUIRED FREQUENCY WILL BE DETERMINED C-CAP/Firestone, Austin, TX 512-282-3611 6

METAL DECK TYPE & GRADE PAINTED, GALVANIZED, STAINLESS STEEL, ACOUSTICAL. GRADES C (30ksi) or E (80ksi) TYPES A, B, F ROOF INSULATION BOARD STOCK WOOD FIBER PERLITE POLYSTYRENE EXPANDED EXTRUDED POLYISOCYANURATE FOAMGLAS GLASS MAT GYPSUM BOARD ROOF COVERING MATERIALS BITUMEN COAL TAR PITCH Asphalt SBS APP SINGLE PLIES THERMOSET EPDM THERMOPLASTIC PVC & PVC BASED TPO C-CAP/Firestone, Austin, TX 512-282-3611 7

ROOF COVERING MATERIALS METAL ROOFING STRUCTURAL METAL STANDING SEAM ARCHITECTURAL METAL CRAFTED METALS FASTEN THROUGH The Roofing System ROOF DECK INSULATION ROOF COVERING AFFIXMENT METHOD PROPER SELECTION OF EACH COMPONENT IS NECESSARY TO FORM A ROOF SYSTEM BASIC ROOFING: Sample Systems C-CAP/Firestone, Austin, TX 512-282-3611 8

MEMBRANES THERMOSET EPDM Single Ply THERMOPLASTIC PVC & PVC BASED TPO EPDM ROOFING SYSTEMS BALLASTED STONE/PAVERS/INSULATED PAVERS FULLY ADHERED SOLVENT/ WATER BASED CONTACT ADHESIVES URETHANE ADHESIVE MECHANICALLY AFFIXED Ballasted System STONE BALLAST/ PAVERS MEMBRANE INSULATION DECK Simple, economical design provides proven performance Stone ballast provides economical UL Class A Fire Rating Design Flexibility - Compatible with most insulation's Wide panel sizes with EPDM provide fast and efficient coverage of large roof areas C-CAP/Firestone, Austin, TX 512-282-3611 9

BALLASTED STONE SURFACING PAVERS PRE-CAST STRUCTURAL CONCRETE SLABS LIGHT WEIGHT INTERLOCKING INSULATING CEMENT FACED (IRMA) Weight and size of ballast are used to resist wind forces Ballasted System Pavers/Ballast Membrane Metal Deck Membranes: EPDM TPO PVC Simple, economical design provides proven performance Stone ballast provides economical UL Class A Fire Rating Design Flexibility - Compatible with most insulation s BALLAST SHOULD BE CLEAN, ROUND AND FREE OF SHARP EDGES. STONE BALLAST /10-13 PSF NOTE THE WALKWAYS IN THE LOWER RIGHT CORNERS. STONE IS DIFFICULT TO WALK ON. EPDM BALLASTED ROOF C-CAP/Firestone, Austin, TX 512-282-3611 10

IRMA ROOF (Inverted Roof Membrane Assembly) Adhered Systems. Membrane ) Adhesive Deck Plates & Fasteners Design Flexibility - Adapts easily to unusual roof profiles or slopes (single-ply only) Excellent for high wind conditions Simple, time-proven application method provides high dependability Factory Mutual Approval available ADHERED TWO BASIC SYSTEMS ADHERED (SINGLE PLIES) ADHESIVE (SOLVENT BASED) LVOC ADHESIVE (WATER BASED) LOW RISE FOAM (POLYUREATHANE) ADHERED (ASPHALT SYSTEMS) HOT ASPHALT COLD ADHESIVE HEAT WELDED (TORCH OR HOT AIR) C-CAP/Firestone, Austin, TX 512-282-3611 11

Adhered Systems Single Ply Membranes: EPDM TPO PVC Membrane Adhesive Fasteners Metal Deck Design Flexibility - Adapts easily to unusual roof profiles or slopes (single-ply only) Excellent for high wind conditions Simple, time-proven application method provides high Dependability Factory Mutual Approval available FULLY ADHERED EPDM ROOF Mechanically Attached System Batten Cover Cover Membrane Metal Metal or or Polymer Batten Polymer Batten Plates & Fasteners Deck Deck Light Weight - Adapts to most roof decks Wide panels provide fast coverage of large roof areas FM 1-60 & FM 1-90 +wind rating is achievable C-CAP/Firestone, Austin, TX 512-282-3611 12

In-Seam Mechanically Attached Membrane Metal or Polymer Batten Embedded in Field Seam Seaming Tape Deck Light Weight - Adapts to most roof decks Smaller panels are ideal for small, complicated or hard to-reach roof areas FM 1-60 wind rating available FM 1-90 wind rating available MECHANICALLY ATTACHED THREE BASIC SYSTEMS: MECHANICALLY ATTACHED METAL BATTEN NYLON BATTEN BATTEN IN THE SEAM (BITS) METAL BATTEN NYLON BATTEN SEAM PLATES AND SCREWS MODIFIED BITUMEN (BITS) METAL BATTEN Mechanically Attached Systems Cover Strip Batten Bar Membrane Fasteners Metal Deck Membranes: EPDM PVC TPO Light Weight - Adapts to most roof decks Wide panels provide fast coverage of large roof areas FM I-60 & FM I-90 wind rating achievable C-CAP/Firestone, Austin, TX 512-282-3611 13

In The Seam Mechanically Attached Systems Membranes: EPDM PVC TPO Light Weight - Adapts to most roof decks Smaller panels are ideal for small, complicated or hard to reach roof areas FM I-60 & FM I-90 wind rating achievable Seam Batten Bar Membrane Fasteners Metal Deck MECHANICALLY FASTENED EPDM MEMBRANES THERMOSET EPDM Single Ply THERMOPLASTIC PVC & PVC BASED TPO C-CAP/Firestone, Austin, TX 512-282-3611 14

TPO/PVC Roofing Systems Fully Adhered 17% of the Market Mechanically Attached 82% of the Market Ballasted < 1 % of the Market WHY? PVC BATTEN IN THE SEAM SYSTEM Reinforced Mechanically Attached System Seam Plate Membrane Fasteners Metal Deck Light Weight - Adapts to most roof decks Smaller panels are ideal for small, complicated or hard to-reach roof areas FM I -60 wind rating available FM I -90 wind rating available C-CAP/Firestone, Austin, TX 512-282-3611 15

With FM - Attachment is the issue Membrane Seam Plates Plates & Fasteners Deck Traits UL Class A Fire Rating High Tear Resistance Compatible with most insulations Wide panel sizes providing fast efficient coverage FM 1-90 Tested *WARNING BE AWARE OF DECK* Typical FM Ratings Bitumen Based Systems Built Up Roof (BUR) Coal Tar Asphalt Modified d Bitumen (MB) APP (Atactic Polypropylene) SBS (Styrene Butadiene Styrene) C-CAP/Firestone, Austin, TX 512-282-3611 16

Built-Up Roofing Aggregate Ply Felts Cover Board Fasteners Metal Deck Membranes: Asphalt Coal Tar Conventional BUR with Multiple Plies installed Shingle Fashion. A Modified Bitumen Cap Sheet can be installed over the plies for a Hybrid system Asphalt Based Systems Hot Mop Applied Torch Applied C-CAP/Firestone, Austin, TX 512-282-3611 17

Modified Bitumen Base Sheet, Interply & Cap Sheet Cap Sheet Interply Base Sheet Fasteners Metal Deck Membranes: SBS APP Modified Bitumen Base Sheet & Cap Sheet Cap Sheet Base Sheet Fasteners Metal Deck Membranes: SBS APP Asphalt Based Systems Adhered SBS Self Adhered SBS C-CAP/Firestone, Austin, TX 512-282-3611 18

Hybrid Roofing MB Cap Sheet Ply Felts Cover Board Fasteners Metal Deck Membranes: Asphalt The Commercial Roofing Market Built-Up Roofing SBS 13% 25% 15% EPDM APP 16% 10% 21% TPO PVC QUESTIONS? This concludes the American Institute of Architects Continuing Education Systems Program Firestone Building Products C-CAP/Firestone, Austin, TX 512-282-3611 19