1 ROOF CONSTRUCTION SCIENCE (METCT092) This training program is intended for applicators that are interested in gaining an understanding of the various technologies incorporated in roof systems, including different types of roof membrane applications, different insulation systems and numerous application methodologies available. None open discussion. In addition, the course will give participants an opportunity to watch demonstrations and participate in workshops for the installation of insulation. 2-3 hours Multiple-choice test. In addition, participants must be able to demonstrate competency in insulation installation methodology. Participants will be able to identify common roof decks upon which roof systems are installed; including steel deck, structural concrete, wood-based products, lightweight insulating concrete and cementious wood fiber. Participants will be able to identify common insulation systems used in roof construction, including polyisocyanurate, perlite, wood fiber, gypsum board and asphaltic cover board. Participants will be able to identify common insulation attachment methods. Participants will be able to identify modified bitumen and single ply roofs.

2 SBS-MODIFIED HEAT WELDED MEMBRANE SYSTEMS (METCT100) This training program is intended for applicators that install heat welded SBS-modified roof systems. It will give applicators who have practical experience, but have not received formal training, the opportunity to upgrade their knowledge base and support the skills they have acquired on the work site. Successful completion of Roof Construction Science (METCT092) is required. demonstrations and participate in workshops for the installation of heat welded roof systems. in heat welded installation methodology. Participants will be able to identify various characteristics of elastomeric bitumen membranes preparations appropriate to the installation of heat welded membrane systems Participants will be able to waterproof standard surfaces with heat-applied elastomeric membranes using a propane torch Participants will be able to waterproof various details and flashing elements with heat welded elastomeric membranes using a propane torch Participants will have an understanding of torch safety.

3 SBS-MODIFIED COLD ADHESIVE-APPLIED MEMBRANE SYSTEMS (METCT102) This training program is intended for applicators that install cold adhesive-applied SBSmodified roof systems. It will give applicators who have practical experience, but who have not received formal training, the opportunity to upgrade their knowledge base and support the skills they have acquired on the work site. Successful completion of Roof Construction Science (METCT092) is required. demonstrations and participate in workshops for the installation of cold adhesive-applied roof systems. in cold adhesive-applied installation methodology. Participants will be able to identify various characteristics of elastomeric bitumen membranes preparations appropriate to the installation of cold adhesive-applied membrane systems Participants will be able to identify the different types of cold adhesive products available Participants will be able to waterproof standard surfaces with cold adhesiveapplied elastomeric membranes using adhesive Participants will be able to waterproof various details and flashing elements with cold adhesive-applied elastomeric membranes using adhesive

4 SBS-MODIFIED MECHANICALLY FASTENED MEMBRANE SYSTEMS (METCT104) This training program is intended for applicators that install mechanically fastened SBSmodified roof systems. It will give applicators who have practical experience, but who have not received formal training, the opportunity to upgrade their knowledge base and support the skills they have acquired on the work site. Successful completion of SBS-Modified Heat-Applied Membrane Systems (METCT100) and SBS-Modified Cold Adhesive-Applied Membrane Systems (METCT102) is required. demonstrations and participate in workshops for the installation of mechanically fastened roof systems. 2-3 hours Multiple-choice test. In addition, participants must be able to demonstrate competency in mechanically attached installation methodology Participants will be able to identify various characteristics of elastomeric bitumen membranes Participants will be able to install a mechanically fastened modified bitumen roof system, understanding the importance of following proper fastening pattern protocols, including prescriptive enhancement situations.

5 LIQUID FLASHING SYSTEMS (METCT107) This training program is intended for applicators that install liquid applied flashing applications. It will give applicators who have practical experience, but who have not received formal training, the opportunity to upgrade their knowledge base and support the skills they have acquired on the work site. Successful completion of Roof Construction Science (METCT092) is required. demonstrations and participate in workshops for the installation of liquid applied flashing systems. in liquid applied flashing installation methodology. Participants will be able to identify various characteristics of liquid applied flashing systems preparations appropriate to the installation of liquid applied flashing systems Participants will be able to waterproof various details and flashing elements with liquid applied flashing applications

6 PVC ADHERED MEMBRANE ROOF SYSTEMS (METCT120) This training program is intended for applicators that install adhered PVC roof systems. It will give applicators who have practical experience, but who have not received formal training, the opportunity to upgrade their knowledge base and support the skills they have acquired on the work site. None demonstrations and participate in workshops for the installation of adhered PVC roof systems. in PVC installation methodology. Participants will be able to identify various characteristics of PVC membranes preparations appropriate to the installation of PVC membrane systems Participants will be able to waterproof standard surfaces with PVC membranes Participants will be able to waterproof various details via heat-welded prefabricated flashing element Participants will have an understanding of the adhesive options available for PVC roof system applications

7 PVC MECHANICALLY FASTENED MEMBRANE ROOF SYSTEMS (METCT121) This training program is intended for applicators that install mechanically fastened PVC roof systems. It will give applicators who have practical experience, but who have not received formal training, the opportunity to upgrade their knowledge base and support the skills they have acquired on the work site. None demonstrations and participate in workshops for the installation of mechanically PVC roof systems. in PVC installation methodology. Participants will be able to identify various characteristics of PVC membranes preparations appropriate to the installation of PVC membrane systems Participants will be able to waterproof standard surfaces with PVC membranes Participants will be able to waterproof various details via heat-welded prefabricated flashing element Participants will be able to install a mechanically fastened PVC roof system, understanding the importance of following proper fastening pattern protocols, including prescriptive enhancement situations.

8 PMMA LIQUID APPLIED ROOF SYSTEMS (METCT140) This training program is intended for applicators that install PMMA liquid applied roof systems. It will give applicators who have practical experience, but who have not received formal training, the opportunity to upgrade their knowledge base and support the skills they have acquired on the work site. None demonstrations and participate in workshops for the installation of PMMA liquid applied roof systems. in PMMA liquid applied installation methodology. Participants will be able to identify various characteristics of PMMA liquid applied systems, including catalyst activation rules and pot life limitations preparations appropriate to the installation of PMMA liquid applied roof systems Participants will be able to waterproof standard surfaces with PMMA liquid applied systems Participants will be able to waterproof various details and flashing elements with PMMA liquid applied systems

SECTION 07550 - MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

SECTION 07550 - MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck. SECTION 07550 - PART I GENERAL 1.01 SECTION INCLUDES A. Vapor barrier (base ply); cover board at existing roof deck. B. Roof insulation at new roof deck. C. Modified bitumen membrane. D. Fluid applied

More information

CHAPTER 7: Building Systems ROOFING SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen

More information

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that

More information

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and

More information

CHICAGO ROOFING CONTRACTORS ASSOCIATION

CHICAGO ROOFING CONTRACTORS ASSOCIATION CHICAGO ROOFING CONTRACTORS ASSOCIATION JANUARY 22, 2016 Roofing Claims & Lawsuits Stephen M. Phillips Hendrick, Phillips, Salzman & Flatt, P.C. 230 Peachtree Street, Suite 2500 Atlanta, GA 30303 (404)

More information

Georgia State University. Urban Life Building Roof Replacement

Georgia State University. Urban Life Building Roof Replacement ENGINEERING AND ENVIRONMENTAL 140 DECATUR STREET SE, ATLANTA, GA 30303 GEORGIA STATE UNIVERSITY - FACILITIES DESIGN & CONSTRUCTION 34 BROAD STREET, SUITE 100 ATLANTA, GA 30303 DRAWING INDEX A-0 PROJECT

More information

BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC.

BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC. 93-106 Revised March 2007 BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC. BITEC APM-4.5T is a torch applied, mineral surfaced,

More information

Best Practices in Roof Design: Sustainable Energy Efficient Reroofing

Best Practices in Roof Design: Sustainable Energy Efficient Reroofing Best Practices in Roof Design: Sustainable Energy Efficient Reroofing Best Practice Roof Design: Sustainable Energy Efficient Reroofing Presented by Edis Oliver, PE Principal 9511 Lake Creek Parkway Austin,

More information

SBS-Modified Bitumen Roof Systems

SBS-Modified Bitumen Roof Systems SBS-Modified Bitumen Roof Systems High performance systems from the developers of SBS-modified bitumen. Siplast s Paradiene 20/30 was selected for the Library of Congress in Washington D.C. Seven hundred

More information

Proven roofing SyStemS

Proven roofing SyStemS Proven Roofing Systems Above all. Roofing challenges are never over our heads At GenFlex, we live to tackle and solve the toughest challenges in roofing. The result is a full line of proven, durable roofing

More information

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,

More information

Low-slope reroofing guidelines

Low-slope reroofing guidelines Low-slope reroofing guidelines by Thomas Bollnow and Joan P. Crowe, AIA The NRCA Roofing and Waterproofing Manual, Fifth Edition, contains reroofing guidelines for steep- and low-slope roofing. The August

More information

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded

More information

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature Thermal Values Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature relative to changing exterior temperatures. By reducing interior temperature

More information

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS TITLE: STANDARDS FOR NEW ROOFING CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS Responsible Organization: Office of Facilities Planning Instructions: This Manual supersedes

More information

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single

More information

Smooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36.

Smooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36. Demolition/Removal of Work 4-ply built up roofing to the insulation (smooth cap sheet) Smooth cap sheet - 0-10 SQ $ 63.00 Smooth cap sheet - 11-50 SQ $ 63.00 Smooth cap sheet - 51-100 SQ $ 35.00 Smooth

More information

APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE

APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT NCE Table Application Type Description Page 1A-1 Wood New, Reroof (Tear-Off), Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 4 1A-2

More information

ANSI/SPRI WD-1 Wind Design Standard Practice for Roofing Assemblies. Table of Contents. 1.0 Introduction...2. 2.0 Methodology...2

ANSI/SPRI WD-1 Wind Design Standard Practice for Roofing Assemblies. Table of Contents. 1.0 Introduction...2. 2.0 Methodology...2 Standard Practice f Table of Contents 1.0 Introduction...2 2.0 Methodology...2 Appendix A...7 Insulation Board Fastening Patterns 4 feet 4 feet Boards Adhered Membranes...8 Insulation Board Fastening Patterns

More information

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.

More information

COMMERCIAL ROOFING. Learning Objectives. Commercial Roofing Fundamentals May 2, 2012

COMMERCIAL ROOFING. Learning Objectives. Commercial Roofing Fundamentals May 2, 2012 COMMERCIAL ROOFING The Fundamentals Firestone Building Products is a Registered Provider with the American Institute of Architects Continuing Education Systems. Credit earned on completion of this program

More information

Durapax Coal Tar BUR Application Guide

Durapax Coal Tar BUR Application Guide 400 Old Reading Pike, Suite 304 Pottstown, PA 19464 Tel: 610-579-9075 Fax: 610-323-0115 www.durapax.com Durapax Coal Tar BUR Application Guide DESIGN CONSIDERATIONS The proper specifications of any roof

More information

Nondestructive Evaluation of USCG. 2401 Hawkins Pt. Road Curtis Bay, MD 21226. Provided by: HurleyIR

Nondestructive Evaluation of USCG. 2401 Hawkins Pt. Road Curtis Bay, MD 21226. Provided by: HurleyIR Nondestructive Evaluation of USCG 2401 Hawkins Pt. Road Curtis Bay, MD 21226 Provided by: HurleyIR On Tuesday May 20 th 2014, HurleyIR provided a nondestructive evaluation for Ruff Roofers of the USCG

More information

Building Owners Guide to a Duro-Last System!

Building Owners Guide to a Duro-Last System! Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof

More information

FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association

FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING Roofing Manufacturers Association Why is a built-up roof considered a multi-ply roof? ARMA defines a built-up roofing system as a roof where multiple

More information

ROOFING CONTRACTORS QUESTIONNAIRE

ROOFING CONTRACTORS QUESTIONNAIRE ROOFING CONTRACTORS QUESTIONNAIRE ALL QUESTIONS MUST BE ANSWERED 1. Applicant Name: Website Address: Address: Years in business under the applicant name: Are you an NRCA (National Roofing Contractors Association)

More information

Roofing Systems. New Applications / Re-Roofing / Maintenance

Roofing Systems. New Applications / Re-Roofing / Maintenance Roofing Systems New Applications / Re-Roofing / Maintenance New Roof Installation In terms of the design and installation of an original roofing system (in conjunction with the construction of a new building),

More information

CRS Sales & Marketing

CRS Sales & Marketing TPO - Technology CRS Sales & Marketing Presenter: Gena Miller Thank you AIA, Sign In Sheet (1 Hour CEU-HSW) Division of CRS, Inc. (Commercial Roofing Specialties) 5 Locations (4 state of GA, 1 state of

More information

UL Online Certifications Directory

UL Online Certifications Directory UL Online Certifications Directory Home Quick Guide Contact Us UL.com TGFU.R11183 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems PACTIV CORP SUITE 175 2100 RIVEREDGE

More information

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance

More information

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof! Table of Contents Section 1: Most Common Types of Flat Roofing Section 2: Better Understand Your Flat Roof Section 3: Flat Roofing Cost in 2015: Four Factors that Dictate Section 4: Planning A Flat Roofing

More information

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced

More information

Please read the entire document before purchasing and installing any of these products

Please read the entire document before purchasing and installing any of these products Please read the entire document before purchasing and installing any of these products USA SBS UNDERLAYMENT ROOFING UNDERLAYMENT SBS Mineral Surfaced MINERAL SURFACE CAP SHEET Ice and Water Protection

More information

Excellence in Waterproofing, Roofing and Surfacing Technology

Excellence in Waterproofing, Roofing and Surfacing Technology Product and Application Guide Excellence in Waterproofing, Roofing and Surfacing Technology High-Performance, Built-to-Last Roofing and Waterproofing Systems With more than 50 years of proven experience,

More information

TEST PROCEDURE FOR FIELD WITHDRAWAL RESISTANCE TESTING

TEST PROCEDURE FOR FIELD WITHDRAWAL RESISTANCE TESTING TESTING APPLICATION STANDARD (TAS) No. 105-98 TEST PROCEDURE FOR FIELD WITHDRAWAL RESISTANCE TESTING 1. Scope 1.1 This Testing Application Standard (TAS) covers procedures for withdrawal resistance testing

More information

Mop it. Stick it. Spread it.

Mop it. Stick it. Spread it. A w a p l a n S B S - m o d i f i e d r o l l r o o f i n g Mop it. Stick it. Spread it. Same proven performance. Now with more ways than ever to apply it. 1 inch 1.5 inch However you apply products, count

More information

Roofing and Sealants. Contents. Section 6. 6.6.3 Single-ply membrane splicing cement. 6.0.0 Most frequently used types of roofing

Roofing and Sealants. Contents. Section 6. 6.6.3 Single-ply membrane splicing cement. 6.0.0 Most frequently used types of roofing Section 6 Roofing and Sealants Contents 6.0.0 Most frequently used types of roofing 6.0.0.1 Built-up membrane roofing 6.0.0.2 Fluid-applied membrane roofing 6.0.0.3 Single-ply membrane roofs 6.0.0.4 Metal

More information

DIY INSPECTION & MAINTENANCE

DIY INSPECTION & MAINTENANCE DIY INSPECTION & MAINTENANCE A Service of the Jewett Roofing Company 800-664-2845 JEWETT ROOFING COMPANY ST. LOUIS, MO - GREENVILLE, IL A Letter from our President Our customers have been the true blessing

More information

PSU WHP ROOF REPLACEMENT

PSU WHP ROOF REPLACEMENT SECTION 075216 - MEMBRANE ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE

COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE www.epdmroofs.org COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE By Ric Vitiello President Forensic Roof Consulting and Hail Damage Assessment Training www.benchmark-services.com

More information

SECTION 07 54 23 PVC SINGLE PLY ROOFING

SECTION 07 54 23 PVC SINGLE PLY ROOFING SECTION 07 54 23 PVC SINGLE PLY ROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Attached GENERAL CONDITIONS, GENERAL NOTES, INSTRUCTIONS TO BIDDERS, AND BID FORM are components of this section. B. Section

More information

What to Do About Your Roof and How to Hire a Roofing Contractor

What to Do About Your Roof and How to Hire a Roofing Contractor ROOFI NG What to Do About Your Roof and How to Hire a Roofing Contractor On those rare occasions when it rains in Arizona and you have a leak, you may wonder if you need a brand new roof, especially if

More information

Rooflight INSTALLATION INSTRUCTIONS

Rooflight INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary

More information

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-

More information

SECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

SECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings. SECTION 07530 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section includes the flowing: 1. Removal of existing roofing membrane. Existing bur roof has one overlay and penetration mastic is asbestos containing.

More information

Modified Bitumen Roofing Membranes

Modified Bitumen Roofing Membranes SPECIFICATIONS The Dibiten Specifications Manual has been prepared to serve as a guide for architects, specifiers, roofing contractors and others involved in the roof system selection and application process.

More information

Indefinite Quantity Unit Price Schedule

Indefinite Quantity Unit Price Schedule Indefinite Quantity Unit Price Schedule DCS # 08002 THIS SET OF BID FORMS IS FOR AREA 4 WORK DESCRIPTION Unit Unit Price Specification Number 2.1 WATERPROOFING & DAMPPROOFING 2.1 10 100 Pressure cleaning.

More information

THE EFFECT OF REFLECTIVE ROOF COATINGS ON THE DURABILITY OF ROOF SYSTEMS

THE EFFECT OF REFLECTIVE ROOF COATINGS ON THE DURABILITY OF ROOF SYSTEMS THE EFFECT OF REFLECTIVE ROOF COATINGS ON THE DURABILITY OF ROOF SYSTEMS Joseph W. Mellott II and Donald C. Portfolio ROOF COATING MANUFACTURERS ASSOCIATION International Roofing Expo TU-03 Technical March

More information

COMMERCIAL BUILDING APPLICATIONS

COMMERCIAL BUILDING APPLICATIONS EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that

More information

CREEK Technical Services, LLC

CREEK Technical Services, LLC EVALUATION REPORT 2010 FLORIDA BUILDING CODE Manufacturer: Henry Company Report Issued February 20, 2013 999 North Sepulveda Blvd., Suite 800 El Segundo, CA 90245 (800) 486-1278 Manufacturing Plants: Quality

More information

Solicitation DTFACN-11-R-00079 Attachment #9

Solicitation DTFACN-11-R-00079 Attachment #9 These specs are only a general overview of the typical VOR Roof construction. These are for reference only. Each individual project will have its own specifications. 1 VOR Roof Projects IDIQ Solicitation

More information

GENERAL REQUIREMENTS HENRY WARRANTED COMMERCIAL ROOFING SYSTEMS

GENERAL REQUIREMENTS HENRY WARRANTED COMMERCIAL ROOFING SYSTEMS GENERAL REQUIREMENTS HENRY WARRANTED COMMERCIAL ROOFING SYSTEMS 1.0 STATEMENT OF POLICY The overall performance of a roofing system can be affected by factors other than the roof system installation. Henry

More information

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side

More information

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry

More information

CONTRACTORS QUESTIONNAIRE

CONTRACTORS QUESTIONNAIRE CONTRACTORS QUESTIONNAIRE ALL QUESTIONS MUST BE ANSWERED (Attach additional paper if necessary) 1. Applicant: A. Years in business under current name: B. Describe your operations: C. Do you currently have,

More information

How To Know If A Reflective Roofmembrane Is More Efficient

How To Know If A Reflective Roofmembrane Is More Efficient Wiss, Janney, Elstner Associates, Inc. 9511 North Lake Creek Parkway Austin, Texas 78717 512.257.4800 tel 512.219.9883 fax Texas Registered Engineering Firm F-0093 www.wje.com Sustainable Energy Efficient

More information

NRCA s steep-slope manual is thoroughly revised for 2013

NRCA s steep-slope manual is thoroughly revised for 2013 Photo courtesy of Boone Brothers Roofing, Omaha, Neb. NRCA s steep-slope manual is thoroughly revised for 2013 by Maciek Rupar 38 www.professionalroofing.net MARCH 2013 P ublished in January, The NRCA

More information

INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group

INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group INNOVATIONS Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems A Company of the SAARGUMMI Group OUR SOLUTION TO REFURBISH ROOFS FOR LONG-TERM DURABILITY Quality and Experience from the Innovation

More information

http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdqtkahqb3dx8wn...

http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdqtkahqb3dx8wn... Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wgevxqwtdqtkahqb3dx8wn... Page 1 of 2 8/3/2015 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats

More information

Prices Effective April 1, 2016

Prices Effective April 1, 2016 Domestic U.S. Warranty Pricing Guide Longer term warranties have additional installation requirements and not all warranty terms are available for all roofing specifications. Please refer to the Firestone

More information

CARLISLE S. c a r l i s l e - s y n t e c. c o m

CARLISLE S. c a r l i s l e - s y n t e c. c o m CARLISLE S Roofing Systems c a r l i s l e - s y n t e c. c o m Put 0 Years of Experience to Work for You For more than 0 years, Carlisle SynTec Incorporated has been the trusted provider of the most dependable

More information

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

Class Number 4470. April 2010. 2010 FM Approvals LLC. All rights reserved.

Class Number 4470. April 2010. 2010 FM Approvals LLC. All rights reserved. Approval Standard for Single-Ply, Polymer-Modified Bitumen Sheet, Built-Up Roof (BUR) and Liquid Applied Roof Assemblies for use in Class 1 and Noncombustible Roof Deck Construction Class Number 4470 April

More information

Roofer On-the-Job Training Guide

Roofer On-the-Job Training Guide Roofer On-the-Job Training Guide Roofers install and maintain built-up roofs, flat deck roofs, steep roofs and other roofs with a variety of covering materials. Training Requirements: 4500 hours (3 years)

More information

LAMA has developed over the years a wide range of products that can be used in the waterproofing

LAMA has developed over the years a wide range of products that can be used in the waterproofing LAMA has developed over the years a wide range of products that can be used in the waterproofing and damp-proofing of roofs, decks, car parkings, walls, foundations, basements, roads, etc. In this catalogue,

More information

SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING

SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Roof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, 2014. RBA Project No. 2014007.00.

Roof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, 2014. RBA Project No. 2014007.00. Report Fairbank Complex 40 Fairbank Road RBA Project No. 2014007.00 Prepared by: 33 Center Street, 2 nd Floor Burlington, MA Tel: 781-273-1537 Fax: 781-273-1695 TABLE OF CONTENTS Roof Repair Project Report...

More information

Class Number 4470. June 2012. 2012 FM Approvals LLC. All rights reserved.

Class Number 4470. June 2012. 2012 FM Approvals LLC. All rights reserved. Approval Standard for Single-Ply, Polymer-Modified Bitumen Sheet, Built-Up Roof (BUR) and Liquid Applied Roof Assemblies for use in Class 1 and Noncombustible Roof Deck Construction Class Number 4470 June

More information

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs CertainTeed Self-Adhering Roof Systems for Low Slope Residential Roofs Goes down fast. Stays on strong. Flintlastic SA performs in all the right ways. What s more important to you? Speed of installation,

More information

SCOPE OF WORK PROVISIONS FOR ROOFER: ROOFER PITCH WORK IMPERIAL AND SAN DIEGO COUNTIES

SCOPE OF WORK PROVISIONS FOR ROOFER: ROOFER PITCH WORK IMPERIAL AND SAN DIEGO COUNTIES STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS Office of the Director Research Unit 455 Golden Gate Avenue, 9 th Floor San Francisco, CA 94102 Edmund G. Brown Jr., Governor MAILING ADDRESS: P.

More information

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam

More information

TARRANT COUNTY DETAIL STANDARDS

TARRANT COUNTY DETAIL STANDARDS TARRANT COUNTY DETAIL STANDARDS 1. Standard Coping 2. Coping at End Wall 3. Standard Sheet Metal Engagement Details 4. Gravel Guard 5. Gravel Guard Wall Termination 6. Gravel Guard, Gutter, and Downspout

More information

DE BOER WATERPROOFING MEMBRANES

DE BOER WATERPROOFING MEMBRANES De Boer Waterproofing Solutions NV Metropoolstraat 33 B-2900 Schoten Belgium Tel: 00 32 3 647 1400 Fax: 00 32 3 646 7703 e-mail: infouk@deboer.be website: www.deboer.be APPROVAL INSPECTION TESTING CERTIFICATION

More information

Site Inspection Report

Site Inspection Report Site Inspection Report Project Title: 1 Canada Square Location: 1 Canada Square, Canary Wharf, London Date of Inspection: 16/05/12 System / Products: TBA (suggested flame free application) Attendees: G

More information

Peel & Seal Self-Stick Roofing Solutions

Peel & Seal Self-Stick Roofing Solutions Peel & Seal Self-Stick Roofing Solutions Ideal for Low Slope Applications Waterproof and Weatherproof Energy Efficient Tough and Durable Versatile, Effective Sealing Around Protrusions Perfect for Vents,

More information

A. Roofing Terminology: Definitions in ASTM D 1079 and glossary in NRCA's "The NRCA Roofing and Waterproofing Manual" apply to work of this Section.

A. Roofing Terminology: Definitions in ASTM D 1079 and glossary in NRCA's The NRCA Roofing and Waterproofing Manual apply to work of this Section. SECTION 075419 POLYVINYL CHLORIDE (PVC) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

If you are a web registered user of ArlingontPermits.com you may also request an inspection at: TECHNICAL BULLETIN Community Development & Planning, Building Inspections TOPIC: Permits & Inspections for Roofing Replacement Effective November 1, 2011 Revised This Technical Bulletin will provide contractors

More information

FATRA ROOF COVERING SYSTEMS FATRAFOL FF807 AND FATRAFOL FF807/V ROOF COVERING SYSTEMS

FATRA ROOF COVERING SYSTEMS FATRAFOL FF807 AND FATRAFOL FF807/V ROOF COVERING SYSTEMS Fatra UK Ltd Unit 12 The Timber Yard East Moors Road Ocean Park Cardiff CF24 5EE Tel: 029 2048 7954 Fax: 029 2048 9226 e-mail: sales@fatra.co.uk website: www.fatra.co.uk FATRA ROOF COVERING SYSTEMS APPROVAL

More information

FIRESTONE APP ROOFING SYSTEMS APPLICATION GUIDE TABLE OF CONTENTS

FIRESTONE APP ROOFING SYSTEMS APPLICATION GUIDE TABLE OF CONTENTS FIRESTONE APP ROOFING SYSTEMS APPLICATION GUIDE TABLE OF CONTENTS 2.01.1 GENERAL...2 2.02.1 JOB SITE CONSIDERATIONS (CAUTION AND WARNINGS)...2 2.03.1 ROOF SUBSTRATE PREPARATION...2 2.04.1 WOOD NAILER LOCATION

More information

Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE

Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE I n t r o d u c t i o n t o M o d i Acres of Roofing. Decades of Performance. Over the past 20 years, Firestone Building Products

More information

THERMOPLASTIC MEMBRANE (PVC) ROOFING Added 11/2012 07 54 19-1 Thermal and Moisture Protection

THERMOPLASTIC MEMBRANE (PVC) ROOFING Added 11/2012 07 54 19-1 Thermal and Moisture Protection SECTION 07 54 19 - SINGLE PLY PVC REROOFING PART 1 - GENERAL 1.1 SUMMARY A. All roofing areas, flashings, penetrations and equipment shall be included in the work under this section. B. Furnish materials

More information

Commercial Roof Systems Selection Guide

Commercial Roof Systems Selection Guide CertainTeed Commercial Roof Systems Selection Guide Good Better Best. Don't specify less. The chart below is a quick guide to choosing the right roof system for your needs. Please note: the best roofs

More information

The Perfect Fit For Metal Retrofit

The Perfect Fit For Metal Retrofit D u r o - S h i e l d M e t a l R e t r o f i t R o o f i n g S y s t e m The Perfect Fit For Metal Retrofit Lock out leaks. Lock in your investment. Has time caught up with your metal roof? There are

More information

FEFPA 2015 SUMMER CONFERENCE. Energy Effectiveness through Roof Coatings and Solar

FEFPA 2015 SUMMER CONFERENCE. Energy Effectiveness through Roof Coatings and Solar FEFPA 2015 SUMMER CONFERENCE Energy Effectiveness through Roof Coatings and Solar Welcome Danny G. Daniel Stokes, CSI, CDT, RCI, CPRC Vice President Advanced Roofing Inc. About Danny Stokes Vide President

More information

Design No. P736 September 26, 2003. Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A)

Design No. P736 September 26, 2003. Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A) Design No. P736 September 26, 2003 Restrained Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Beam Ratings 1, 1-1/2 or 2 Hr (See Items 7 and 8A) 1. Beam

More information

BLACK JACK ALL WEATHER ROOF COATING

BLACK JACK ALL WEATHER ROOF COATING PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.

More information

Protecting Roofing Systems Against Windstorm Damage

Protecting Roofing Systems Against Windstorm Damage Protecting Roofing Systems Against Windstorm Damage This brochure is made available for informational purposes only in support of the insurance relationship between FM Global and its clients. This information

More information

Maintaining Your Roof

Maintaining Your Roof Maintaining Your Roof Roofs play a key role in protecting building occupants and interiors from outside weather conditions, primarily moisture. The roof, insulation and ventilation must all work together

More information

ROOFER TRADE REGULATION

ROOFER TRADE REGULATION Province of Alberta APPRENTICESHIP AND INDUSTRY TRAINING ACT ROOFER TRADE REGULATION Alberta Regulation 301/2000 With amendments up to and including Alberta Regulation 1/2011 Office Consolidation Published

More information

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within

More information

CONTINENTAL MATERIALS, INC. ALL-WEATHER APP INSTALLATION GUIDELINES

CONTINENTAL MATERIALS, INC. ALL-WEATHER APP INSTALLATION GUIDELINES CONTINENTAL MATERIALS, INC. ALL-WEATHER APP INSTALLATION GUIDELINES Page 1 APP INSTALLATION GUIDELINES This guide provides instructions for the installation of CMI All Weather APP roofing materials. Any

More information

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY CI/SfB Oct 12 (47) Ln Uniclass L524 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY Bailey Flame-free felt roofing Bailey

More information

EPDM. Roofing systems

EPDM. Roofing systems Roofing systems Our Promise Through ongoing interchange of experiences with contractors, Mule-Hide keeps on top of the latest roofing requirements and solutions Trusted in roofing since 1906, Mule-Hide

More information

SECTION 07500 - ROOFING SYSTEMS

SECTION 07500 - ROOFING SYSTEMS SECTION 07500 - ROOFING SYSTEMS PART 1 - GENERAL 1.1 SCOPE OF SECTION A. This section contains the requirements relating to thermal and moisture protection as specifically provided by low slope and steep

More information

Firestone SBS Modified Bitumen Roofing System Design and Application Guide

Firestone SBS Modified Bitumen Roofing System Design and Application Guide SBS Modified Bitumen Roofing System Design and Application Guide October, 2013 Table of Contents 1.01 Introduction... 1 1.01.1.1 General Considerations... 1 1.01.1.2 Warranty... 3 1.01.1.3 QUALITY ASSURANCE...

More information

Avoiding the Landfill: The Recycling of Vinyl Roof Membranes

Avoiding the Landfill: The Recycling of Vinyl Roof Membranes Avoiding the Landfill: The Recycling of Vinyl Roof Membranes With its European counterparts blazing the trail, the North American vinyl (PVC) roofing industry has entered a new phase in its commitment

More information

Proper roof slope and drainage are important to prevent excessive water accumulation

Proper roof slope and drainage are important to prevent excessive water accumulation Proper roof slope and drainage are important to prevent excessive water accumulation by Jason P. Wilen, AIA, CDT, RRO P onding water sometimes occurs on membrane roof systems as a result of snow, rainfall

More information

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 SECTION B1: PREPARATION GUIDE B1.1 INTRODUCTION... B1-1

More information

Table of Contents. Dedicated to Service and Support

Table of Contents. Dedicated to Service and Support A Roofing Resource for More Than a Century and a Half, Look to Johns Manville for Superior Service and Comprehensive Solutions That Perform for the Long Term. 2 Table of Contents Introduction 2 Modified

More information