UL Online Certifications Directory

Size: px
Start display at page:

Download "UL Online Certifications Directory"

Transcription

1 UL Online Certifications Directory Home Quick Guide Contact Us UL.com TGFU.R11183 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems PACTIV CORP SUITE RIVEREDGE PKY ATLANTA, GA USA R11183 SINGLE PLY MEMBRANE ROOFING SYSTEMS Class A - Ballasted Green Guard insulation board may be uniform thickness or tapered. 1. Deleted. 2. Deck: NC Incline: 2 Membrane: Any UL classified. Insulation: One or more layers "Green Guard ", any thickness Slip sheet (Optional) : Phillips Fibers "Rufon", loose laid. Surfacing: River bottom stone (3/4 to 1-1/2 in. diam) 1000 lb/sq. Class A- Fully Adhered 1. Deck: NC Incline: 1/2 Insulation: One layer " Green Guard PB6FA, PB6WFA, PG38FA or PG39FA".

2 Membrane: Carlisle Syntec "Carlisle FR EPDM" 45 or 60 mil., fully adhered with "B-500" bonding adhesive, applied at 1 gal/sq. Class A - Mechanically Fastened 1. Deck: NC Incline: 1/4 Barrier Board: 3/4 in. Perlite. Insulation: One or more layers "Green Guard ", 3 in. max, laid loosely or mechanically Membrane: Cooley " C-3 " (CPE), mechanically fastened with large metal fasteners spaced 18 in. OC and max 2 in. from membrane's edge. Adjacent sheets are lapped 4 in. covering fasteners. Laps are then heat sealed. 2. Deck: NC Incline: 1/4 Barrier Board: 3/4 in. Perlite. Insulation: One or more layers "Green Guard ", 3 in. max, loose laid or mechanically Membrane: J. P. Stevens "Hi-Tuff" (CSM) or "Hi-Tuff EP" (TPO), fastened to the deck with metal screws and discs. The laps are hot air welded. 3. Deck: NC Incline: 2 Barrier Board: 1/2 in. (min) fiberboard. Membrane: Versico "Hysunite" (CSPE) 45 mil. 4. Deck: NC Incline: 1 Barrier Board: "Micore", 1/2 in. min, fiberboard 1/2 in. min or gypsum board, 5/8 in min. Membrane: Versico "Versigard" EPDM. 5. Deck: NC Incline: 1 Insulation: "Green Guard ", 3 in max. Barrier Board: 1/2 in min fiberboard. Membrane: Firestone "Ultra Ply" (TPA). 6. Deck: NC Incline: 1/4 Barrier Board: 1/2 in. min fiberboard. Membrane: Firestone "Standard RubberGard" (EPDM) 45 or 60 mil. 7. Deck: NC Incline: 1 Barrier Board: Carlisle HP Recovery Board, 1/2 in. min. Membrane: Carlisle "FR Reinforced" (EPDM) "Standard Reinforced", in. 8. Deck: NC Incline: 1/4. Barrier Board: 1 in. (min) perlite. Membrane: Duro Last Roofing "Duro-Last" (PVC). 9. Deck: NC Incline: 2

3 Barrier Board: 1 in. (min) fiberboard or 3/4 in (min) perlite. Membrane: "Bond Cote 30, 35 or 40". 10. Deck: NC Incline: 1 Barrier Board: 1/2 in. gypsum wallboard. Membrane: "Genflex ACR" (EPDM), 45 mil. 11. Deck: NC Incline: 2 Membrane: J.P. Stevens "Hi-Tuff" or "Hi-Tuff 40" (CSM). 12. Deck: NC Incline: 1 Insulation: "Green Guard PB6FF" 3/8 in. thick max. Membrane: Sarnafill "S327" or Duro-Last Inc. "Duro-Last" (PVC) 13. Deck: NC Incline: 1 Insulation: "Green Guard PB6FF" 3/8 in. thick max. Membrane: Firestone "Standard Rubbergard", "Standard Reinforced RubberGard", "Fire Retardant RubberGard", or "LS-FR"(EPDM) MAINTENANCE AND REPAIR SYSTEMS Class A 1. Deck: NC Incline: 1/4 Existing Roof System: Class A, B or C, gravel surfaced, (gravel must be maintained at 400 lb/sq) covered with: Slip Sheet: One layer " Green Guard PB6, PB6W, PG38 or PG39". Membrane: Duro-Last Roofing "Duro-Last" (PVC), mechanically 2. Deck: NC Incline: 1/4 Existing Roof System: Class A, B or C covered with: Slip Sheet: One layer " Green Guard PB6, PB6W, PG38 or PG39". Membrane: Any UL Classified membrane. Surfacing: River bottom stone (3/4 to 1-1/2 in. diam), 1000 lbs/sq. 3. Deck: NC Incline: 2 Membrane: "Duro-Last Roofing " Duro-Last" (PVC), mechanically 4. Deck: NC Incline: 1/4 Membrane: J. P. Stevens "Hi-Tuff" (CSM) or Hi-Tuff EP (TPO), mechanically

4 5. Deck: NC Incline: 1-1/2 Membrane: J. P. Stevens "Hi-Tuff" (CSM) or "Hi-Tuff EP" (TPO), mechanically 6. Deck: C15/32 Incline: 2 lb/sq) covered with: Slip sheet: Atlas "FR-10" or "FR-11". Membrane: "Duro-Last Roofing " Duro-Last" (PVC), mechanically 7. Deck: C15/32 Incline: 1/4 lb/sq) covered with: Membrane: J. P. Stevens "Hi-Tuff" (CSM) or "Hi-Tuff EP" (TPO), mechanically 8. Deck: C15/32 Incline: 1-1/2 lb/sq) covered with: Insulation: " Green Guard PB6, PB64, PB6W, PG3 or PG39". Membrane: J. P. Stevens "Hi-Tuff" (CSM) or "Hi-Tuff EP" (TPO), mechanically 9. Deck: NC Incline: 1 Existing Roof System: Class A, B or C cap sheet, smooth or gravel surfaced BUR (gravel must be maintained) covered with: Insulation: " Green Guard PB6, PB6W, PB64, PG38 or PG39". Membrane: Seaman "Fiber Tite" (EIP). 10. Deck: NC Incline: 1 Existing Roof System: Class A, B or C cap sheet, smooth or gravel surfaced BUR (gravel may be Insulation: " Green Guard PB6-Plus". Membrane: Johns Manville "SR-50", "SR-60" or "SR-80", mechanically attached. 11. Deck: C-15/32 Incline: 1/4 lb/sq.) covered with: Insulation: " Green Guard PB6, PB6W, PG38 or PG39". Membrane: Genflex (TPO), mechanically 12. Deck: C-15/32 Incline: 1/4 lb/sq.) covered with:

5 Insulation: " Green Guard PB6, PG38 or PG39". Membrane: Carlisle "Sure-Weld" (TPO), "Sure-Weld GSD" (TPO), Versico "Versiweld Premier" (TPO) or "Versiweld Premier EF" (TPO), mechanically 13. Deck: NC Incline: 1/4 Existing Roof System: Class A, B or C built-up system, cap sheet or gravel surfaced (gravel may be removed). Insulation: "AMOCOR-PB6, PB6W, PG38 or PG39", mechanically Slip Sheet: Atlas "FR 10", mechanically Membrane: Carlisle "Sure-Weld GSD" (TPO) or Versico "Versiweld Premier EF" (TPO) membrane, mechanically 14. Deck: NC Incline: 1 Existing Roof System: Class A, B or C built-up system, cap sheet or gravel surfaced (gravel may be removed). Insulation: " Green Guard PB6, PB6W, PG38 or PG39", mechanically Membrane: Carlisle "FR Reinforced" EPDM membrane, mechanically 15. Deck: NC Incline: 1 Existing Roof System : Class A, B or C cap sheet, smooth or gravel surfaced BUR (gravel may be Insulation : " Green Guard PB6W". Membrane : Duro-Last Roofing, "Duro-Last" (PVC), mechanically Class B 1. Deck: NC Incline: 1/2 Existing Roof System: Class A, B or C smooth or gravel surfaced, (gravel may be Membrane: J. P. Stevens "Hi-Tuff" (CSM) or "Hi-Tuff EP" (TPO), fastened to the deck with metal screws and discs. The membrane laps are hot air welded. 2. Deck: C15/32 Incline: 1/2 Existing Roof System: Class A or B gravel surfaced, (gravel maintained at 400 lb/sq) covered with: Membrane: J. P. Stevens "Hi-Tuff" (CSM) or "Hi-Tuff EP" (TPO), fastened to the deck with metal screws and discs. The membrane laps are hot air welded. Class A, B or C 1. Deck: C-15/32 Incline: 1/4 Existing Roof System: Class A, B or C smooth or gravel surfaced (gravel maintained at 400 lb/sq) to maintain existing Classification covered with: Insulation: " Green Guard PB6, PB6, PB6W, PG38 or PG39". Membrane: J.P. Stevens "Hi-Tuff" (CSM) or "Hi-Tuff EP" (TPO), mechanically 2. Deck: C-15/32 Incline: 1/4 Existing Roof System: Class A, B or C smooth or gravel surfaced (gravel maintained at 400 lb/sq) to maintain existing Classification covered with: Insulation: " Green Guard PB6, PB6, PB6W, PG38 or PG39".

6 Membrane: J.P. Stevens "Hi-Tuff" (CSM) or "Hi-Tuff EP" (TPO), mechanically 3. Deck: C-15/32 Incline: 1 Existing Roof System: Class A, B or C gravel surfaced (gravel maintained at 400 lb/sq.) to maintain existing Classification covered with: Insulation: " Green Guard PB6, PB6W, PB64, PG38 or PG39". Membrane: Seaman "Fiber Tite" (EIP). 4. Deck: C-15/32 Incline: 1/2 Existing roof system: Class A, B or C cap sheet or gravel surfaced BUR gravel, to be maintained to retain existing Classification, covered with: Insulation: One layer " Green Guard PB6FA, PB6WFA, PG38FA or PG39FA". Membrane: Carlisle's "FR EPDM", 45 or 60 mil., fully adhered with "B-500" bonding adhesive, applied at 1 gal/sq. 5. Deck: C15/32 Incline: 1/4 maintained at 400 lb/sq) covered with: Insulation: Green Guard PB6W. Membrane: Duro-Last Roofing, "Duro-Last" (PVC), mechanically 6. Deck: C15/32 Incline: 1/4 Existing Roof System: Class A, B, or C smooth, capsheet, gravel-surfaced BUR (gravel maintained at 400 lbs. / sq.) to maintain existing classification covered with: Insulation: GreenGuard PB6, PB6W, PB6 PLUS, PG38, or PG39. Membrane: Any UL classified CPE, CSPE, CSM, EIP, NBP, PVC, TPO, mechanically attached. 7. Deck: C15/32 Incline: 1/2 Existing Roof System: Class A, B, or C gravel-surfaced BUR (gravel maintained at 400 lbs. / sq.) to maintain existing classification covered with: Insulation: GreenGuard PB6, PB6W, PB6 PLUS, PG38, or PG39. Membrane: Sarnafill "S327" (PVC), mechanically attached. 8. Deck: C15/32 Incline: 1/2 Existing Roof System: Class A, B, or C gravel-surfaced BUR (gravel maintained at 400 lbs. / sq.) to maintain existing classification covered with: Insulation: GreenGuard PB6, PB6W, PB6 PLUS, PG38, or PG39. Membrane: Any UL classified CPE, CSPE, EIP, NBP, PVC, mechanically attached. 9. Deck: C-15/32 Incline: 1 Existing Roof System: Class A, B, or C smooth, Type G3 mineral-surfaced capsheet or gravel-surfaced BUR (gravel maintained at 400 lbs. / sq.) to maintain existing classification covered with: Insulation: GreenGuard PB6FA. Membrane: Firestone "Fire Retardant RubberGard" (EPDM) or in. or Carlisle "Sure-Seal FR EPDM"0.045 or in. adhered with 3M "Scotch Weld 78HT" bonding adhesive at 0.20 gal/sq. 10. Deck: C-15/32 Incline: 1/4

7 Existing Roof System: Class A, B, or C gravel-surfaced BUR (gravel maintained at 400 lbs. / sq.) to maintain existing classification covered with: Insulation: GreenGuard PB6FA. Membrane: Any UL classified TPO or PVC adhered with 3M "Scotch Weld 78HT" bonding adhesive at 0.20 gal/sq. Copyright 2009 Underwriters Laboratories Inc. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 2009 Underwriters Laboratories Inc. "

Design No. P736 September 26, 2003. Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A)

Design No. P736 September 26, 2003. Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A) Design No. P736 September 26, 2003 Restrained Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Beam Ratings 1, 1-1/2 or 2 Hr (See Items 7 and 8A) 1. Beam

More information

UL Online Certifications Directory

UL Online Certifications Directory UL Online Certifications Directory OCD Home Quick Guide Contact Us UL.com BXUV.D972 Fire Resistance Ratings - ANSI/UL 263 Page Bottom Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire

More information

HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION

HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION ADVANCED TECHNOLOGY FROM OWENS CORNING TRUMBULL ASPHALT TruLo Lo Odor and TruLo Max asphalt raising the roof on asphalt performance.

More information

Best Practices in Roof Design: Sustainable Energy Efficient Reroofing

Best Practices in Roof Design: Sustainable Energy Efficient Reroofing Best Practices in Roof Design: Sustainable Energy Efficient Reroofing Best Practice Roof Design: Sustainable Energy Efficient Reroofing Presented by Edis Oliver, PE Principal 9511 Lake Creek Parkway Austin,

More information

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that

More information

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and

More information

APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE

APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT NCE Table Application Type Description Page 1A-1 Wood New, Reroof (Tear-Off), Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 4 1A-2

More information

CHAPTER 7: Building Systems ROOFING SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen

More information

COMMERCIAL BUILDING APPLICATIONS

COMMERCIAL BUILDING APPLICATIONS EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that

More information

COMMERCIAL ROOFING. Learning Objectives. Commercial Roofing Fundamentals May 2, 2012

COMMERCIAL ROOFING. Learning Objectives. Commercial Roofing Fundamentals May 2, 2012 COMMERCIAL ROOFING The Fundamentals Firestone Building Products is a Registered Provider with the American Institute of Architects Continuing Education Systems. Credit earned on completion of this program

More information

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded

More information

FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association

FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING Roofing Manufacturers Association Why is a built-up roof considered a multi-ply roof? ARMA defines a built-up roofing system as a roof where multiple

More information

Roofing Systems. New Applications / Re-Roofing / Maintenance

Roofing Systems. New Applications / Re-Roofing / Maintenance Roofing Systems New Applications / Re-Roofing / Maintenance New Roof Installation In terms of the design and installation of an original roofing system (in conjunction with the construction of a new building),

More information

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance

More information

Smooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36.

Smooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36. Demolition/Removal of Work 4-ply built up roofing to the insulation (smooth cap sheet) Smooth cap sheet - 0-10 SQ $ 63.00 Smooth cap sheet - 11-50 SQ $ 63.00 Smooth cap sheet - 51-100 SQ $ 35.00 Smooth

More information

Laboratory Report P12850.03.09. Simulated Wind Uplift Testing of Adhered Single-Ply Roofing Systems in accordance with FM Standard 4470, Appendix C

Laboratory Report P12850.03.09. Simulated Wind Uplift Testing of Adhered Single-Ply Roofing Systems in accordance with FM Standard 4470, Appendix C Simulated Wind Uplift Testing of Adhered Single-Ply Roofing Systems in accordance with FM Standard 4470, Appendix C Prepared for: 2100 River Edge Parkway, Suite 175 Atlanta, GA 30328 Date of Issuance:

More information

BXUV.D946 - Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

BXUV.D946 - Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263 BXUV.D946 Fire Resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements

More information

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof! Table of Contents Section 1: Most Common Types of Flat Roofing Section 2: Better Understand Your Flat Roof Section 3: Flat Roofing Cost in 2015: Four Factors that Dictate Section 4: Planning A Flat Roofing

More information

Building Owners Guide to a Duro-Last System!

Building Owners Guide to a Duro-Last System! Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof

More information

SECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

SECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings. SECTION 07530 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section includes the flowing: 1. Removal of existing roofing membrane. Existing bur roof has one overlay and penetration mastic is asbestos containing.

More information

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within

More information

REPLACE ROOFING DENVER CENTRAL LIBRARY PHASE I CITY & COUNTY OF DENVER DENVER, COLORADO

REPLACE ROOFING DENVER CENTRAL LIBRARY PHASE I CITY & COUNTY OF DENVER DENVER, COLORADO PUBLIC LIBRARY PHASE I 4828 W. 6TH Avenue, Unit B-8 Golden, Colorado 8040 Phone: (303) 233-092 VICINITY MAP SHEET INDEX GT /26/2009 SHEET DESCRIPTION G.0 COVER SHEET R.0 COMPOSITE ROOF PLAN R. NEW ROOF

More information

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590

More information

LAYERED GREEN ROOF DETAILS

LAYERED GREEN ROOF DETAILS LAYERED GREEN ROOF DETAILS LGR1.01 LGR1.02 LGR1.03 LGR2.01 LGR2.02 LGR2.03 LGR3.01 LGR3.02 LGR3.02 LGR4.01 LGR5.01 LGR5.02 LGR5.03 LGR5.04 LGR5.05 LGR6.01 [A-D] EXTENSIVE GREEN ROOF [A-C] SEMI-INTENSIVE

More information

ITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING

ITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING DESCRIPTION Construct adhered membrane roofing system, roof insulation, and vapor retarder in accordance with these specifications. MATERIALS: General: Provide installed roofing membrane and base flashings

More information

The Building Group First Tuesdays First Saint Paul s Lutheran Church 1301 North LaSalle Street, Chicago, Illinois

The Building Group First Tuesdays First Saint Paul s Lutheran Church 1301 North LaSalle Street, Chicago, Illinois Wiss, Janney, Elstner Associates, Inc. 10 South LaSalle Street, Suite 2600 Chicago, Illinois 60603 312.372.0555 tel 312.372.0873 fax www.wje.com The Building Group First Tuesdays October 2, 2012 Jason

More information

ROOF CONSTRUCTION SCIENCE (METCT092)

ROOF CONSTRUCTION SCIENCE (METCT092) ROOF CONSTRUCTION SCIENCE (METCT092) This training program is intended for applicators that are interested in gaining an understanding of the various technologies incorporated in roof systems, including

More information

Test Report. Root Penetration Resistance Test. of Waterproofing Membrane for Green Roof System

Test Report. Root Penetration Resistance Test. of Waterproofing Membrane for Green Roof System Beijing Institute of Landscape and Gardening Test Report Root Penetration Resistance Test of Waterproofing Membrane for Green Roof System According to JC/T 1075-2008 Attachment A (standard attachment)

More information

Get Rid of Roof Problems for Good. How spray foam roofing can protect your building and make you money

Get Rid of Roof Problems for Good. How spray foam roofing can protect your building and make you money Get Rid of Roof Problems for Good How spray foam roofing can protect your building and make you money What is a Spray Foam Roofing System? 300 MILLION Board feet of roofing spray foam installed annually

More information

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC

More information

REQUEST FOR PROPOSALS

REQUEST FOR PROPOSALS Page 1 of 6 REQUEST FOR PROPOSALS Issue Date: 2/19/2013 RFP# WHS-2013-001 Title: Services for roofing improvements and annual roof assessments, Windsor School Complex, State Street, Windsor, Vermont Issuer

More information

Durapax Coal Tar BUR Application Guide

Durapax Coal Tar BUR Application Guide 400 Old Reading Pike, Suite 304 Pottstown, PA 19464 Tel: 610-579-9075 Fax: 610-323-0115 www.durapax.com Durapax Coal Tar BUR Application Guide DESIGN CONSIDERATIONS The proper specifications of any roof

More information

BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC.

BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC. 93-106 Revised March 2007 BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC. BITEC APM-4.5T is a torch applied, mineral surfaced,

More information

A. Roofing Terminology: Definitions in ASTM D 1079 and glossary in NRCA's "The NRCA Roofing and Waterproofing Manual" apply to work of this Section.

A. Roofing Terminology: Definitions in ASTM D 1079 and glossary in NRCA's The NRCA Roofing and Waterproofing Manual apply to work of this Section. SECTION 075419 POLYVINYL CHLORIDE (PVC) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Georgia State University. Urban Life Building Roof Replacement

Georgia State University. Urban Life Building Roof Replacement ENGINEERING AND ENVIRONMENTAL 140 DECATUR STREET SE, ATLANTA, GA 30303 GEORGIA STATE UNIVERSITY - FACILITIES DESIGN & CONSTRUCTION 34 BROAD STREET, SUITE 100 ATLANTA, GA 30303 DRAWING INDEX A-0 PROJECT

More information

COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE

COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE www.epdmroofs.org COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE By Ric Vitiello President Forensic Roof Consulting and Hail Damage Assessment Training www.benchmark-services.com

More information

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318 Fire Barrier Moldable Putty+ Pads 123 Columbia Court North Suite 201 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 e-mail: [email protected] Visit Our Web Site at www.fireretardantsinc.com Protecting

More information

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,

More information

Firestone Warranty Program

Firestone Warranty Program EPDM Warranty Pricing ***For Red Shield Contractors Only*** Red Shield 20 Years $0.10 $500.00 No Dollar Limit 15 Years $0.07 $400.00 No Dollar Limit 10 Years $0.04 $350.00 No Dollar Limit When Firestone

More information

Roof Inspection and Evaluation

Roof Inspection and Evaluation Roof Inspection and Evaluation Sylvester Powell Community Center 6200 Martway Mission, KS 66202 Prepared For: Your name Sample Community Center 6200 Martway Mission, KS 66202 Kansas City, MO 64105 200

More information

Prices Effective April 1, 2016

Prices Effective April 1, 2016 Domestic U.S. Warranty Pricing Guide Longer term warranties have additional installation requirements and not all warranty terms are available for all roofing specifications. Please refer to the Firestone

More information

CREEK Technical Services, LLC

CREEK Technical Services, LLC EVALUATION REPORT 2010 FLORIDA BUILDING CODE Manufacturer: Henry Company Report Issued February 20, 2013 999 North Sepulveda Blvd., Suite 800 El Segundo, CA 90245 (800) 486-1278 Manufacturing Plants: Quality

More information

The existing roof angle change terminations and flashings when sound and intact can be reused.

The existing roof angle change terminations and flashings when sound and intact can be reused. January 2, 2015 Summary Specification Re-Skinning an Existing Roof Maintenance and Repair Warranty Upgrade for Up to 30 Years Re-Skinning Over an Existing Roof with a New C-EPDM Membrane Using The Existing

More information

CRS Sales & Marketing

CRS Sales & Marketing TPO - Technology CRS Sales & Marketing Presenter: Gena Miller Thank you AIA, Sign In Sheet (1 Hour CEU-HSW) Division of CRS, Inc. (Commercial Roofing Specialties) 5 Locations (4 state of GA, 1 state of

More information

SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING

SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Roof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, 2014. RBA Project No. 2014007.00.

Roof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, 2014. RBA Project No. 2014007.00. Report Fairbank Complex 40 Fairbank Road RBA Project No. 2014007.00 Prepared by: 33 Center Street, 2 nd Floor Burlington, MA Tel: 781-273-1537 Fax: 781-273-1695 TABLE OF CONTENTS Roof Repair Project Report...

More information

How To Know If A Reflective Roofmembrane Is More Efficient

How To Know If A Reflective Roofmembrane Is More Efficient Wiss, Janney, Elstner Associates, Inc. 9511 North Lake Creek Parkway Austin, Texas 78717 512.257.4800 tel 512.219.9883 fax Texas Registered Engineering Firm F-0093 www.wje.com Sustainable Energy Efficient

More information

ISO Types 1-6: Construction Code Descriptions

ISO Types 1-6: Construction Code Descriptions ISO 1 Frame (combustible walls and/or roof) Class 1B Buildings where the exterior walls are wood or other combustible materials, including construction where the combustible materials are combined with

More information

Dynamic Wind Testing of Commercial Roofing Systems

Dynamic Wind Testing of Commercial Roofing Systems Construction Technology Update No. 55 Dynamic Wind Testing of Commercial Roofing Systems by A. Baskaran Single-ply roofs (SPRs) behave differently than built-up roofs and a simple test method is needed

More information

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry

More information

Asphalt-Applied and Cold Application Built-Up Roofing Application Guide

Asphalt-Applied and Cold Application Built-Up Roofing Application Guide 1.0 General Information 1.1 The following section provides the application specifications currently available from Johns Manville (JM) for built-up roofing membranes and covers both hot asphalt and cold

More information

FIRESTONE BUILT-UP ROOFING SYSTEMS APPLICATION GUIDE 3/14/2011

FIRESTONE BUILT-UP ROOFING SYSTEMS APPLICATION GUIDE 3/14/2011 FIRESTONE BUILT-UP ROOFING SYSTEMS APPLICATION GUIDE TABLE OF CONTENTS 2.01.1 GENERAL......2 2.02.1 JOB SITE CONSIDERATIONS (CAUTION AND WARNINGS)...2 2.03.1 ROOF SUBSTRATE PREPARATION...2 2.04.1 WOOD

More information

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS TITLE: STANDARDS FOR NEW ROOFING CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS Responsible Organization: Office of Facilities Planning Instructions: This Manual supersedes

More information

Design No. L556. Design No. L556

Design No. L556. Design No. L556 1 of 9 3/17/2015 6:15 PM Design No. L556 BXUV.L556 Fire Resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted

More information

Roof Inspection Report 3840 Greenway Circle, Lawrence Kansas, 66046 Sauer-Danfoss Building

Roof Inspection Report 3840 Greenway Circle, Lawrence Kansas, 66046 Sauer-Danfoss Building Roof Inspection Report 3840 Greenway Circle, Lawrence Kansas, 66046 Sauer-Danfoss Building Prepared For: Ms Marilyn Bittenbender Colliers International 805 New Hampshire St Lawrence Kansas, 66046 Prepared

More information

SECTION 07 54 23 PVC SINGLE PLY ROOFING

SECTION 07 54 23 PVC SINGLE PLY ROOFING SECTION 07 54 23 PVC SINGLE PLY ROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Attached GENERAL CONDITIONS, GENERAL NOTES, INSTRUCTIONS TO BIDDERS, AND BID FORM are components of this section. B. Section

More information

AATC ROOF WORK INSTRUCTIONS

AATC ROOF WORK INSTRUCTIONS AATC ROOF WORK INSTRUCTIONS COMPLETE THE UTILITY NOTIFICATION FOR RECEIVE APPROVAL FROM AATC FOR PRE WORK PHOTOS ROOF SCANS EQUIPMENT TAPE OFF ROOF WORK ROOF CORING/PENETRATIONS REPAIR OF MEMBRANE PRE

More information

CARLISLE S ROOFING SYSTEMS EPDM TPO PVC FLEECEBACK ROOF GARDEN

CARLISLE S ROOFING SYSTEMS EPDM TPO PVC FLEECEBACK ROOF GARDEN CARLISLE S ROOFING SYSTEMS EPDM TPO PVC FLEECEBACK ROOF GARDEN Put 50 Years of Experience to Work for You For nearly half a century, Carlisle SynTec has been the trusted provider of the most dependable

More information

COMMERCIAL & LOW SLOPED ROOF SPECIALISTS TOTAL NDL SYSTEM MANUFACTURER WARRANTIES

COMMERCIAL & LOW SLOPED ROOF SPECIALISTS TOTAL NDL SYSTEM MANUFACTURER WARRANTIES C COMMERCIAL & LOW SLOPED ROOF SPECIALISTS We are equipped to handle the largest of your commercial roof needs. Whether storm damage or simply needing a new commercial roof due to age, Cobalt allows you

More information

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC 0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND

More information

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs CertainTeed Self-Adhering Roof Systems for Low Slope Residential Roofs Goes down fast. Stays on strong. Flintlastic SA performs in all the right ways. What s more important to you? Speed of installation,

More information

Roof Condition Analysis

Roof Condition Analysis Roof Condition Analysis Prepared for: J.W. Nelson John Evans Middle School - Gym Dome 2900 15th Avenue Greeley, Colorado Prepared by: Gregory Ham Coastal Specified Products 5252 Sherman Street Denver,

More information

Roof Systems Overview

Roof Systems Overview Roof Systems Overview Cold Applied Built-Up Roofing Systems BURmastic Tremco s line of cold applied built-up roofing systems. BURmastic 200 Combines Tremco s expertise in asphalt blending technology with

More information

DISTRICT OF BARRIERE REQUEST FOR PROPOSAL

DISTRICT OF BARRIERE REQUEST FOR PROPOSAL DISTRICT OF BARRIERE REQUEST FOR PROPOSAL SUPPLY AND INSTALLATION OF FLAT ROOF SYSTEM AND RELATED REPAIRS RFP No. 2014-02 1. SUMMARY OF REQUIREMENT The District is planning on reroofing the existing flat

More information

Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE

Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE I n t r o d u c t i o n t o M o d i Acres of Roofing. Decades of Performance. Over the past 20 years, Firestone Building Products

More information

Achieving Maximum Roof Performance at the Lowest Installed Cost With Invinsa Roof Board

Achieving Maximum Roof Performance at the Lowest Installed Cost With Invinsa Roof Board Achieving Maximum Roof Performance at the Lowest Installed Cost With Roof Board By: Mandy Schweitzer, MBA, RRO, and Joe Noernberg, MIM, RRO, CDT Executive Summary Commercial roof reliability, strength

More information

Tremco Fire Protection Systems Group Technical Bulletin

Tremco Fire Protection Systems Group Technical Bulletin Compartmentalization products and design play a key role in protecting lives and property from fire. Understanding the tools and techniques available for firestopping is of utmost importance to designers,

More information

SECTION 07550 - MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

SECTION 07550 - MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck. SECTION 07550 - PART I GENERAL 1.01 SECTION INCLUDES A. Vapor barrier (base ply); cover board at existing roof deck. B. Roof insulation at new roof deck. C. Modified bitumen membrane. D. Fluid applied

More information

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

CHESTERFLEX ROOF WATERPROOFING MEMBRANES CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED

More information

07 5423-1 THERMOPLASTIC-POLYOLEFIN ROOFING (TPO) Data Center

07 5423-1 THERMOPLASTIC-POLYOLEFIN ROOFING (TPO) Data Center PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 07 5423 THERMOPLASTIC-POLYOLEFIN ROOFING (TPO) Data Center A. Tear off existing roof system down to wood deck and install new Thermoplastic membrane roofing

More information

FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS

FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS Table of Contents Chapter 1: FLAT ROOF REPAIR - CUT COST WITHOUT CUTTING CORNERS Chapter 2: PVC RECOVER SYSTEM HOW IT WORKS Chapter 3: 8 STRATEGIES TO

More information

ROOF ASSEMBLIES CHAPTER 9

ROOF ASSEMBLIES CHAPTER 9 CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. SECTION R902 ROOF CLASSIFICATION

More information

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION As of October 1, 2007, this mitigation form must be submitted as part of the roofing permit application package. Secondary water barrier (if applicable)

More information

Site Inspection Report

Site Inspection Report Site Inspection Report Project Title: 1 Canada Square Location: 1 Canada Square, Canary Wharf, London Date of Inspection: 16/05/12 System / Products: TBA (suggested flame free application) Attendees: G

More information

Indefinite Quantity Unit Price Schedule

Indefinite Quantity Unit Price Schedule Indefinite Quantity Unit Price Schedule DCS # 08002 THIS SET OF BID FORMS IS FOR AREA 4 WORK DESCRIPTION Unit Unit Price Specification Number 2.1 WATERPROOFING & DAMPPROOFING 2.1 10 100 Pressure cleaning.

More information

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET Environmental Protection and Growth Management Department PERMITTING, LICENSING AND CONSUMER PROTECTION DIVISION 1 N. University Drive, Box #302 Plantation, Florida 33324 954-765-4400 www.broward.org/permittingandlicensing

More information

ATLAS Roofing Products

ATLAS Roofing Products ATLAS Roll Roofing Products World s Largest producer of roofing s Preferred by roofing professionals. Atlas has you covered on every part of the job, even what goes under your roofing. We are proud to

More information

Commercial Roof Systems Selection Guide

Commercial Roof Systems Selection Guide CertainTeed Commercial Roof Systems Selection Guide Good Better Best. Don't specify less. The chart below is a quick guide to choosing the right roof system for your needs. Please note: the best roofs

More information

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.

More information

3 Installation. 9 Roof Edges... p. 3. 19 10 Wall Terminations... p. 3. 20 11 Membrane Repair... p. 3. 21 12 Miscellaneous... p. 3. 22. 3.

3 Installation. 9 Roof Edges... p. 3. 19 10 Wall Terminations... p. 3. 20 11 Membrane Repair... p. 3. 21 12 Miscellaneous... p. 3. 22. 3. 3 Installation The information provided within this chapter may assist the contractor to install the Firestone UltraPly TPO Systems in accordance with Firestone s requirements. It may also help him and

More information

Crescent Valley High School Roof Investigation

Crescent Valley High School Roof Investigation Crescent Valley High School Roof Investigation Project: Corvallis School District Crescent Valley High School Roof Date: July 26, 2011 Report By: Rowell Brokaw Architects: Mark Young, AIA, Chris Andrejko

More information

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information

EPDM System Repair and Cleaning

EPDM System Repair and Cleaning EPDM single-ply roof systems have represented a third of the volume of the low-sloped commercial market for close to twenty years. The majority of these roofs were installed to receive the manufacturer

More information

SchoolRoof Repair - Cost For Replacement of a Student Roof, Part 2

SchoolRoof Repair - Cost For Replacement of a Student Roof, Part 2 ROOF REPAIR UPDATE For the November school newsletter, I wrote an article in which I explained the condition of the school roof, the estimated cost of replacing the three flat sections from the 1996 building

More information

Proven roofing SyStemS

Proven roofing SyStemS Proven Roofing Systems Above all. Roofing challenges are never over our heads At GenFlex, we live to tackle and solve the toughest challenges in roofing. The result is a full line of proven, durable roofing

More information

Firestone SBS Modified Bitumen Roofing System Design and Application Guide

Firestone SBS Modified Bitumen Roofing System Design and Application Guide SBS Modified Bitumen Roofing System Design and Application Guide October, 2013 Table of Contents 1.01 Introduction... 1 1.01.1.1 General Considerations... 1 1.01.1.2 Warranty... 3 1.01.1.3 QUALITY ASSURANCE...

More information

Warranty Information TABLE OF CONTENTS PROCEDURES FOR WARRANTY 2

Warranty Information TABLE OF CONTENTS PROCEDURES FOR WARRANTY 2 Warranty Information TABLE OF CONTENTS PROCEDURES FOR WARRANTY 2 PROTECTING YOUR DURO-LAST ROOFING 3 Safety Measures 3 Inspection 3 Maintenance Program 4 Sealants 4 Drainage 4 Parapets Walls 4 Building

More information

Jm Tpo systems Single Ply Roofing

Jm Tpo systems Single Ply Roofing JM TPO Systems Single Ply Roofing JM TPO Systems A Company You Know and Trust JM TPO manufacturing facility in Scottsboro, AL JM s Commitment to Single Ply and TPO Johns Manville (JM) is recognized as

More information

Epdm Flat Roofing Systems

Epdm Flat Roofing Systems Epdm Flat Roofing Systems EDPM can be fully bonded, loose laid and ballasted or mechanically attached depending on the existing roof and its proposed usage. This applies to roofs to be refurbished and

More information

Avoiding the Landfill: The Recycling of Vinyl Roof Membranes

Avoiding the Landfill: The Recycling of Vinyl Roof Membranes Avoiding the Landfill: The Recycling of Vinyl Roof Membranes With its European counterparts blazing the trail, the North American vinyl (PVC) roofing industry has entered a new phase in its commitment

More information

Table of Contents. Dedicated to Service and Support

Table of Contents. Dedicated to Service and Support A Roofing Resource for More Than a Century and a Half, Look to Johns Manville for Superior Service and Comprehensive Solutions That Perform for the Long Term. 2 Table of Contents Introduction 2 Modified

More information