Fire & Security DETECTORS



Similar documents
Analogue addressable devices

Buckeye Detection Systems Fixed Detection Systems Application Survey

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

DUCT SMOKE DETECTOR D4120

D287/D288/D292/D293A/D293E

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

FIRERAY 2000 Installation Guide

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

rpsa FIRE PROTECTION ENGINEERS

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Ammonia Detection System Codes and Design Specifications

Model: DC-A2IO Advanced HVAC Controller

Premier M Plus & Infinity 8

Module 5. Fire and Emergency Alarm System Part I- Basics

CO2 Alarm. Operation. Application

Global System Technology(UK) PLC The Intelligent Solution

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

PLAN REVIEW GUIDE FOR FIRE ALARM

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

conventional system operation

Fire detection equipment

Overview of Standards for CO Detection Products

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

SECTION DETECTION AND ALARM

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

Y7230A CO 2 Alarm System

AlarmSense 2-wire detection and alarm system. Product Guide

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

CQM1-SF200/CS1W-SF200

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

Triple Waveband Infra-Red Flame Detection

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

TMS TANK MANAGEMENT SYSTEM

SECTION FIRE ALARM AND DETECTION SYSTEMS

Section D..General Auto Electrical Corporation

MINERVA MX MX Virtual Multi-Sensor Detectors

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Heating, air-conditioning, cooling

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Smoke Detectors Ordering Information DS230 DS230 Series Heat Detectors DS230F DS233F Peripheral Accessories EOL200 TP280 Bases Features

Manual for Fire Suppression & Methane Detection System

WD-AMX Water Detection Controllers

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

White Paper. Best Practices for Gas Monitoring in the Commercial Kitchen

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

SMART SENSOR COLLECTION

RRV934. Multi-controller. Synco living

Radiant Temperature Sensor TY7321

FIREDEX Conventional Fire Panels

HERNANDO COUNTY FIRE ALARM GUIDELINES

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Fibaro electronic modules are smallest devices of the type in the World and can be installed in all standard wall switch boxes,

How To Install A Carbon Monoxide Detector

DCP Fan Controller. Version 01/2009. The engineer s choice

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

CB Zone Conventional Control Panel

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Heating Controller. Building Technologies HVAC Products

Residential & Commercial Alarm Systems by Gross Security, LLC

Fire Alarm Control Panel. Family. Operating Manual

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM

HVAC Processes. Lecture 7

Process Instrumentation

Smoke Detector PSD 2 & 4 Wire Units

FIRE DETECTION SYSTEMS

Ammonia Detection System Codes and Design Specifications. Brian EuDaly, P.E. Calibration Technologies, Inc.

Fire Alarm System Accessories

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PSTN Home Alarm System

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

The supplier and installer of the system should be approved by the local civil defence authority.

TS93 EMR T/PT/TDE. Surface applied door closer

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

USB-500/600 Series Low-Cost Data Loggers and Accessories

Bold items are particular to the City of Euless

Fire Standards & Regulations Are you confused?

HERZ-Thermal Actuators

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

Speed Control Relays SX2

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Amerex CPS FM-200 Waterless Pre-engineered Fire Suppression System

TrueAlarm Fire Alarm Systems

Electronic Control Devices The European Product Catalogue 2007

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Transcription:

Fire & Security DETECTORS

Smoke Sensitivity 0.98 ~.0%/ft Obscuration Ceiling Spacing 50 foot rating for heat sensor Temperature Range 10ºC to 50ºC Humidity 0 to 95% RH, no condensation or icing Dimensions 100mm (dia.) x6mm (ht) with base Weight 130g/set with base SF119 Model / wire Heat Sensor Setting Voltage DC (Min. /Max.) (1/V) Surge StartUp Permissible Cycle Contact SF119L SF119.H 135±5ºF 10.8~33V 10.8~33V /55mA /55mA 160μA 160μA Remote LED SF119HL 135±5ºF 10.8~33V /55mA 160μA Remote LED SF1191/ SF119H1/ 135±5ºF 1/V 1/V 30/5mA 30/5mA Form A Form A The range includes: SF119L SF119H SF119HL SF1191/ SF119ARB1/ SF119H1/ wire photoelectric smoke alarm with remote LED output wire photoelectric smoke and heat alarm wire photoelectric smoke alarm with remote LED output wire photoelectric smoke alarm (1/VDC) wire photoelectric smoke alarm with autoreset function and Buzzer (1/VDC) wire photoelectric smoke and heat alarm with Buzzer (1/VDC) or wire models Sleek lowprofile housing design. Durable sensor head, no need for replacement. SMD circuit board designsatisfactory quality and reliability guaranteed. Integrated heat detector for SF 119H and SF 119H models. Oneyear limited warranty.

Response Temperature: Fixed temperature:57ºc (135ºF) or RateofRise Ceiling Spacing: 050 foot rating for heat sensor Reset Voltage: less than 1 volt Indicator: LED continously emiting red light Remote Output: 5mA max., diode gate Temperature Range: 10ºC to 50ºC Permissible : maximum Humidity: 0 to 95% RH, no condensation or icing Contact: (for wire) NO or NC Operation, Form A: 1.0A@30VDC/0.5A@15VAC SF91 Model / wire Voltage DC (Min. /Max.) (1/V) Surge StartUp Permissible Cycle Contact SF91 SF91L SF911/ 10~33V 10~33V 1/V 5μA 5μA 5μA 50mA 50mA 30mA 100μA 100μA 100μA Form A The range includes: SF91 SF91L SF91 wire heat alarm wire heat alarm with remote LED output wire heat alarm (1/VDC) Conventional Heat Detector All of the S FIRE s SF91 series detectors provide fast and reliable response for heat 57ºC (135ºF) or Rateof Rise detection. They are intended for use in wire/ wire Class A supervised zone circuits. The SF91 series detectors are subject to panel compatibility limits and compliance with corresponding NFPA 7E standards, locals codes and ordinances. or wire models. Sleek lowprofile housing design. Durable sensor head, no need for replacement. SMD circuit board designsatisfactory quality and reliability guaranteed.

Unit Dimensions: 98mm (Diameter) x 7mm (Height) Operating Temperature: 10ºC to 50ºC Ambient Humidity: 5%~95% RH Horn: >75dB with Autoreset at 3m (10 feet) Relay Rating (if available): NO or NC operation, Rating: 1.0A@30VDC/0.5A@15VAC (resistive load) Power Consumption: W to : 70ppm within 75 minutes; 150ppm within 35 minutes; 00ppm within 10 minutes. Notice: the sensitivity can be calibrated. Weight: 170g with base. SF530 Model Gas Monitored / wire Operating Voltage Output 1V /V 1V / V SF530R Carbon Monoxide 1/VDC Relay 85mA / 50mA / 50mA Carbon Monoxide Detector: SF530 series alarms is single and multiple station carbon monoxide alarms, indented for protection in ordinary indoor locations of dwelling units, including recreational vehicles, mobile homes and recreational boats with enclosed accommodation spaces and cockpit areas. SF530 with relay intended for monitoring the enviroment and intended for open area protection and for connection to a compatible power or control unit for operation as part of CO detection or emergency signaling system, or intended fo control of ventilation or shut off devices such as fans or control valves. The unit is designed for DC wirein application, the gas alarm can be mounted on ceiling or wall. To detect CO gas (Carbon Monoxide). Sensitivity can be calibrated. Figaro semiconductor sensor heads. Sleek lowprofile housing design. SMD circuit board design. Magnet test feature. Sounding aloud alarm signal of exceeding 85dB in alarm mode. Fiveyear limited warranty.

Operating Temperature: 10ºC to 50ºC Ambient Humidity: 30%~95% RH Horn: >75dB with Autoreset at 3m (10 feet) Power Consumption: W Min Gas Level for ing: Less than 10% LEL Relay Rating (if available): NO or NC operation, Rating: 1.0A@30VDC/0.5A@15VAC (resistive load) Dimensions: 98mm (Diameter) x 3mm (Height) Weight: 170g with base SF518 Model Gas Monitored / wire Operating Voltage Output 1V /V 1V / V SF518NR Liquefied Gas 1~VDC Relay 90mA / 56mA / 50mA Gas Detectors: SF518 series detectors is effective for detecting any buildup of natural gas and liquefied gas. The detector ideal for use in home, small commercial properties and recreational vehicles, the detector with relay intended for monitoring the environment and intended for open area protection and for connection to a compatible power control unit for operation as part of gas detection or emergency signaling system, or intended for control of ventilation or shut off devices such as fnas or control valves. The unit is designed for DC wirein application. The gas alarm can be mounted in high (for methane gas) or low (for LPG gas) location. To detect combustible gas (NG, LPG). Sensitivity can be calibrated. Figaro semiconductor sensor heads. Loud 75dB sound signal at alarm mode. Sleek lowprofile housing design. SMD circuit board design. Magnet test featur. Fiveyear limited warranty.