Meter, Meter Reading Instrument (MRI) and Base Computer Software for Meter Data Management (MDM) Vivek Pathak Secure Meters A specifically designed programme for Da Afghanistan Breshna Sherkat (DABS) Afghanistan 11/10/2010 1
Technologies have evolved over a period of time and so have the meters 11/10/2010 2
Conventional meters Meters conventionally measured a single quantity kwh kvarh kvah Meters were used for commercial purpose, (record consumption and bill to consumer) 11/10/2010 3
MDI PSEB 28 11/10/2010 th January 42009 4 This was the meter in good old days
The modern meter has evolved over time Today s meter is different from yesterday s meter What is the difference? 11/10/2010 5
Today s meters are data loggers they churn out a lot of data They give much more than energy readings 11/10/2010 6
Each meter can log a lot of data Data is useful, only if it is purpose oriented 11/10/2010 7
Yesterday Single parameter (kwh) Single reading Manual reading Error prone Manual computation Error prone again! Multiple parameters Multiple readings (load survey) Electronic reading Less error prone Computers aid computations Less errors Today 11/10/2010 8
Advantages of electronic meters More accurate than electromechanical meters They are data loggers & log time stamped data They are read electronically & human errors eliminated Remote reading is possible (LPR, PSTN, GSM, GPRS) They can detect & log illogical events (tampers) Appropriate for consumer end meters only 11/10/2010 9
Yesterday, with electro mechanical meters Manual reading Consumption determined locally Today, with modern electronic meters Read electronically, not from display Complicated tariffs Consumption determined from computer, far away from meter Software (BCS) needed for data extraction This only extracts data from the meter 11/10/2010 10
Metering system software meter has a large amount of data, not practical to read using Software supplied by display, better to read meter manufacturers is Electronically not sufficient for Third party application deriving information software or services are from the data now needed We will deal with Meter Reading and system software for meter reading/ data extraction. 11/10/2010 11
Engineering plastic enclosure, better aesthetics LCD display with Backlight Over view of Electronic meter Calibration LED Inductively coupled PPU Rating plate Button for reverse scrolling Optical Port for electronic reading Front side sealing arrangement Button for display scrolling / scroll lock Extended terminal Block (Transparent) Terminal Block 11/10/2010 12
Information available in modern electronic meters 11/10/2010 13
Display & logged parameters Information in electronic meters can be classified as Display mode Auto display (for quick reference) Push button display (for detailed information) Scrolls automatically Displays Can be parameters accessed by for meter reader consumer viewing To see Can history be viewed data & tamper from information window when meter is Useful sealed to identify meters that need closer investigation Information is of consumer interest 11/10/2010 14
Display Parameters Information shown on the display of electronic meter TOU definition Self diagnostics LED Segment check Battery & NVM health RTC date & time Basic information Meter serial no. Instantaneous parameters V, I, PF, kw, kvar etc. Power On/Off hours Rising demand with elapsed time Billing information TOU wise MDs 6 or 12 history data Tamper information Missing potential Current reverse Short/Open circuit Load imbalance Date/time in RTC Cumulative Registers Cum count of events 11/10/2010 15
Logged Parameters 11/10/2010 16
Logged Parameters Capacity to log parameters is a key feature of electronic meters Logged parameters can be categorized as Instantaneous parameters Billing information Load survey Events or tampers Transactions These are electrical parameters as seen by meter at the time of reading or can be read locally using MRI Can cover Voltage, Current, PF, kw, kvar, kva etc. They are interpreted & displayed in the BCS 11/10/2010 17
Logged Parameters Capacity to log parameters is a key feature of electronic meters Logged parameters can be categorized as Instantaneous parameters Billing information Load survey Events or tampers Transactions These are based on tariff type programmed to meter These are packets of information on billing parameters like energy, MD etc. for each billing cycle They are also interpreted & displayed in the BCS 11/10/2010 18
Capacity to log parameters is a key feature of electronic meters Logged parameters can be categorized as Instantaneous parameters Billing information Load survey Events or tampers Transactions Logged Parameters They are periodic interval-wise information, intervals known as SIP SIP is typically ½ hour for consumer meters & ¼ hour for boundary meters Generally average values of kwh, kvarh, kvah, frequency, PF, Voltages, Currents, Power Down Time etc. 11/10/2010 19
Logged Parameters Capacity to log parameters is a key feature of electronic meters Logged parameters can be categorized as Instantaneous parameters Billing information Load survey Events or tampers Transactions They are never a conclusive proof that a No consumer meter can has be tampered called tamper proof meter These are simply illogical electrical events as seen by meter The correct way is to refer to them as events and not tampers Modern meters have 3 types of tamper related features Tamper proof features Tamper deterrent features 11/10/2010 20 Tamper evident features
Logged Parameters Capacity to log parameters is a key feature of electronic meters Logged parameters can be categorized as Instantaneous parameters Billing information Load survey Events or tampers Transactions They are interchange of information between meter & MRI They include change of tariff programme in meter, definition of kvarh & kvah, resetting MD, changing date/time etc. 11/10/2010 21
Meter Reading Instrument (MRI) 11/10/2010 PREPARED BY: Kailash Jain 22
What Is MRI? Hand Held Unit (HHU) for Meter Reading. Small, compact DOS or Windows Computer, PDA Capable to communicate with : Static Energy Meters /computer 11/10/2010 23
Uses of MRI Data collection from Meter Can read different make meters with Common MRI (CMRI) Instantaneous Parameters checked by installcheck S/w 11/10/2010 24
Features Of MRI Battery operated Instrument. Comprises of : A Keypad. LCD Display. Communication Ports. Charger Connector. Pre loaded Software. 11/10/2010 25
Analogic MRI LCD Screen Power/Resume Switch & Status LEDs 45 Key Membrane Keypad 4-6 MB for data storage 2 MB for program storage 16 line display ( 16 *24 ) 100% PC Compatibility in a Rugged Hand Held Runs MS-DOS and Virtually any PC Program PC Communications Software at up to 115K bps Optional second RJ-11 Port through built-in 11/10/2010 26
Communication Ports, Optical Cord & Charger RS 232 Port RJ-11 Port Charger Pin Battery Charger Common Optical cord 11/10/2010 27
MRI - Battery Environment friendly battery Line or battery powered Quick charging Light weight charger One can use the MRI even when charger is connected Battery self discharge rate is low. With survey reads 200 meters data & without survey reads 400 meters data for 8 MB. (Depends on memory size) 11/10/2010 28
MRI - Software Before meter reading battery healthy condition can be checked. Allows local reading of Electrical parameters and display of vector diagram Displays Energy values, used for meter testing on site. MRI is a computer, programmed as dumb terminal or DATA TRANSPORTER. 11/10/2010 29
Menu Visible on MRI Screen 1 SEMS 2 SEMS-CHK 3 L&T 4 PHASOR 5 DUKE 6 BATLEVEL Pressing Option-1 for Secure Meter 0. Quit 1.Read Meter Data 2.Dump Data 3.Read Energy 4.Calibration 5.Terminal 6.Space 7.Identification No 8.Load survey Days 11/10/2010 30
Electronic Meter Reading Methods Direct Reading through MRI. Reading by Low Power Radio. Reading by GSM/GPRS/PSTN. 11/10/2010 31
Electronic Meter Reading Methods Direct Reading by MRI Meter reader required to read meter at a particular location Communication Cable Electronic Meter MRI compatible with Meter Vendor software Power Pack unit used when Power is off to power up meter 11/10/2010 32 Meter data is stored in MRI
Meter Data Downloading After Reading the Meter its Data can be downloaded in respective BCS( Base Computer Software). This data contains all the data like Instantaneous, Billing, Load Survey, Event & Transaction data. File name extension of data is.mrd 11/10/2010 33
Base Computer Software (BCS) Meter make BCS 1. Secure Smart2k 2. L&T Vincom 3. PRI UK Integrator 11/10/2010 34
SMART 2000 Base Computer Software 11/10/2010 35
Overview Smart 2K Stands for Secure Meters Analysis & Reporting Tool. SMART 2000 is BCS (Base Computer Software) part of Integrated metering system Energy Meter BCS ( Base Computer Software) MRI ( Meter Reading Instrument) It records energy, electrical parameters, tamper and load survey data. It collects data from the meters using MRI or with modem & telephone line (RMR). These data may be used for analysis and monitoring with the help of Smart 2000 analysis and report tool. Smart 2000 works on Windows platform. Older version working on DOS was Sems Pack. 11/10/2010 36
Features Gives logical view of all the meter reading data according to various parameters like: Instantaneous parameter, Current energy & bill energy data, Time of day energy register data, MDs, Abnormal electrical condition data Perform various other operations called transactions on the meter like Authenticated MD reset, update Date & Time, Tariff, etc. Organized storage of meter reading data and consumer data. New user(s) with their level of access rights could be defined and / manage by supervisor based upon their usage. 11/10/2010 37
Features (Contd ) Exporting the meter data in the industry standard common formats (like ASCII, CSV) so data can be used by other software for billing or otherwise. Load survey information is displayed graphically whereby user has an option to see multiple parameters on the same graph or on a separate view. All the information displayed on the screen can be printed and permanent record can be maintained. Customer can choose what is to be printed. Selection on category such as Energy, Survey, Transaction, etc or on subcategory such as Main energy, Bill energy, TOD energy, history of energy registers etc. 11/10/2010 38
Smart 2000 Main Screen 11/10/2010 39
Main Menu Centre Window Right Hand Side Window Left Side Window Status Bar 11/10/2010 40
Main Menu - General 11/10/2010 41
Upload data in Smart2k 11/10/2010 42
Upload data in Smart2k 11/10/2010 43
Different Mode for Meter Selection 11/10/2010 44
Meter Selection Reading Date, Consumer Detail and MRD Path of Selected Meter 11/10/2010 45
Analysis Report To view the following parameters double click on the selected meter s MRD file: Instantaneous Parameter Energy Values Load Survey Events Report Transaction 11/10/2010 46
Instantaneous Parameters We can view Instantaneous Parameter in two different ways Tabular View Date & Time Frequency Voltage Line Current Active Current Reactive Current Power Factor Active Power, Apparent Power, Reactive Power Average Power Factor Phasor Diagram 11/10/2010 47
Instantaneous Parameters 11/10/2010 48
View - Energy Values Divided into three category - General, Energy & Demand General is divided into seven different view General, Bill Dates, Flags, Power ON/OFF, Power Factor, TOD PF, Tamper Count. Energy Main energy, TOD energy, Consumption, Mid-Night data, TOD consumption. Demand Max demand, TOD, CMD 11/10/2010 49
View - Energy Values 11/10/2010 50
View - Energy Values 11/10/2010 51
View - Energy Values 11/10/2010 52
View - Energy Values 11/10/2010 53
View - Energy Values 6 no. History s cumulative Energy is present 11/10/2010 54
View - Energy Values History 1 TOD Registers- 8 no. TOD Registers 11/10/2010 55
View - Energy Values Consumption between two Histories 11/10/2010 56
View - Energy Values Max Demand for History 1 with date and time 11/10/2010 57
View - Energy Values Daily Energy values at midnight 11/10/2010 58
View Load Survey With Mouse movement on the graph we could see particular IP value Keep the scaling fixed from page to page Select the color of your choice Select the graph of your choice Convert load survey data into text file Five different graphs Demand, Energy, Voltage, Current, Power Factor. 11/10/2010 59
View Load Survey No. of Parameter Depends on meter Clem and utility requirement 11/10/2010 60
View Load Survey Time Slot 11/10/2010 61
View Load Survey 11/10/2010 62
View Load Survey 11/10/2010 63
View Events Could see the following tamper of your interest: R-Ph, Y-Ph, B-Ph missing potential R-Ph, Y-Ph, B-Ph missing current Power Failed See tamper with snapshot & summary details such as tamper count & duration for which meter has remained under tamper Convert the tamper data into text file 11/10/2010 64
View Events 11/10/2010 65
View Events 11/10/2010 66
View Events Count of Tamper and cumulative time 11/10/2010 67
Convert Wizard (Multiple Meters Data Conversion) 11/10/2010 68
Why Convert Wizard is used Converted files of meter data can be opened in notepad or MS-Excel for further analysis. Multiple meters converted files are large in number which may further be imported in third party software to get metering information Report. 11/10/2010 69
Main Menu - Data Check parameter which is to be converted 11/10/2010 70
Converted Data file- Load Survey Each Half hour 8 no. Parameters are logged Each Half hour data is logged 11/10/2010 71
Converted Data file- Tamper Event B Phase voltage at occurrence and restoration of event B phase missing potential is easily seen with time stamped 11/10/2010 72
Converted Data file- Instantaneous Time Drift found All Parameters are instant parameters at time of reading 11/10/2010 73
Converted Data file- Energy History 1 parameter along with billing date and time, billing energy and billing MD may be found 11/10/2010 74
Converted Data file- Midnight Daily midnight energy data can be found 11/10/2010 75
Converted Data file- Transaction No transaction with meter is done after 6/8/2006 11/10/2010 76
System Configuration Operating Systems: Window 98, Window 2000, Windows XP Minimum hardware configuration: Celeron 550 MHz / P-III based PC with 64 MB of RAM. 20 GB hard disk space for software and for storing meter reading data. A color monitor with 1024 X 768 resolution is required. CD drive (32X or higher) is required to install the software. An external modem is must in case you plan to use the remote meter reading feature. COM port 11/10/2010 77
Security SMART2K - Benefits Uses unique security keys to validate meter data for its authenticity. Create levels of user with different rights. It has its own database where consumer, metering information like meter no, CT PT ratio, address and EMF can be stored. Used for meter data analysis. Backward compatibility for all the meters made by SML Meter reading Direct meter reading without MRI can be done Manual / automatic reading at predefined time Modem sharing possible 11/10/2010 78
Export meter data SMART2K - Benefits Select what is to be exported Field width, Decimal digits, Order in which parameter should appear etc File format such as text file, spreadsheet file, database file etc Back up facility of Meter database and Meter data files On line data monitoring can be done. 11/10/2010 79
Questions Please 11/10/2010 80