1 CRE Monitor Instructions Manual CRE TECHNOLOGY believes that all information provided herein is correct and reliable and reserves the right to update at anytime. CRE TECHNOLOGY does not assume any responsibility for its use. 1/11
2 TABLE OF CONTENT 1. CRE MONITOR Utilities installation CRE MONITOR Connection options Procedure for standard TCGEN2.0 via serial cable connected to a PC Procedure for ACGEN2.0/ICGEN2.0/TCGEN2.0 connection via TCP/IP converter... 4 (communication networks LAN/Ethernet) 2-2 On-line management Settingd and measures General commands Hardware section I/Ostatus Curves customization Program section Program menus Fx Virtual I/O Alarms list Messages log Data-logger function Export /11
3 REMOTE CONTROL SOFTWARE - TCGEN2.0/ACGEN2.0/ICGEN CRE MONITOR Utilities installation To install the CRE MONITOR software, you have to start with the CRE MONITOR utilities setup.exe file that you ll find on our website ( / products/softwares/acgen2.0/acgen2.0/tcgen2.0) To install the setup, you must start the setup as an administrator. When installed, you can find all the programs pressing Start > All programs > CRE TECHNOLOGY > TCGEN2.0 software from your softwares list. 2. CRE MONITOR Once you launch CRE MONITOR, follow the instructions by «CRE REMOTE MANAGER» tool that permits to access to the «CRE MONITOR». 1. The software asks you the type of project installed on the TCGEN2.0; find that file. Project to install are available on the website with CRE MONITOR; Files are: CRE_TCGEN2.0_XX and CRE_ACGEN2.0_XX 3. When selected, press «next» to go ahead. 2-1 Connection options Then you will see a window for the choice of the type of connection between the PC and the product. If you only want to prepare a setting file, you can select the Offline option. If you want to connect to the board and directly set the parameters or visualize the measures, choose a connection option (Serial, GSM, TCP/IP). Note that the option USB cannot be chosen for the TCGEN Procedure for standard TCGEN2.0 via serial cable connected to a PC You must use the cable P/N: A63WO 3a.1 3a.2 3a.3 3a.4 3a.5 3/11
4 3a.1. Select Serial as type of connection; 3a.2. Select the COM port number; 3a.3. Select the speed for RS232 connection, this parameter must be the same of Connectivity setup - par. E of the TCGEN2.0; Par. D must be Modbus Slave for RS485 connection, this parameter must be the same of Connectivity setup - par. C of the TCGEN2.0. Par. B must be Modbus Slave; 3a.4. Only for RS485 connection: slave address that must be identical to parameter A of Connectivity setup of the TCGEN2.0; 3a.5. Confirm «Next» to move forward Procedure for ICGEN2.0/ACGEN2.0/TCGEN2.0 connection via TCP/IP converter (communication networks LAN / Ethernet) 3c.1 3c.2 3c.3 3c.4 3c.1. Select TCP/IP; 3c.2. TCGEN2.0 identification number (usually «1»); 3c.3. IP address assigned to the network cable connected to the converter; 3c.4. Enter serial port number of the serial port on converter (always «4000»). 2-2 On-line management When you are Online, you can use the Remote Control Software with the same procedure normally used when you are in front of the controller ICGEN2.0/ACGEN2.0/TCGEN2.0; you should use the mouse to act on the buttons. A red box will help you to locate the button you are selecting. The online management is selectable in the upper part of the window. NOTE: The online option is not available if you select the Offline connection mode. NOTE 2: For connection with AC & ICGEN2.0, the online management will display the TCGEN When you have your mouse cursor on buttons active, these are highlighted by a red square. Click the left mouse button to activate it 4 4/11
5 2-3 Settings and measures When you change the mode to «Settings», you can check all the measurements, all the states of input / output settings and the list log. This option is available also if you selected the Offline mode This window shows the name of the connected device (in this case TCGEN2.0), with 4 different sections: - Hardware: this section shows the status of the inputs and outputs. There is also the possibility to create the custom curve for the three different analog sensors; - Program: this section contains all the parameters of the controller divided in menus like they appear in the programmation menus of the ICGEN2.0/ACGEN2.0/TCGEN2.0. Also, here you can find the data-logger section and the events log; - Strings: this section contains the alarms strings that can be changed and translated in the different languages. It s useful for the user alarms, that can be named with the proper name or definition; - Export: section to export the values of the most important measures in an excel table General commands Login: command used for the login. It s active only if the project is protected with a password. Here are the information: > User: ADVANCED >PASSWORD: TCGEN20 - Save all : command to save all the parameters, alarms and curves actually set in the controller in a.ters file; - Load all : command to load in the controller all the parameters of a.ters file; - Load different : special command to load in the controller only some parameters of a.ters file; The parameters that will be inserted in the controller are only the parameters of the.ters file that are different from the default values present in the project used to connect to the controller, i.e the same project used at paragraph 4-2, point 1: - Custom logo: command to insert a customized logo in the controller. It will be visible at the turn on of the controller. Choose the desired logo (it must be 128x64 pixel,.bmp format, monochromatic); - Update texts: command to modify the languages in the second, third and fourth position of the controller. The first language, english, cannot be modified. You can open a dedicated file. Please ask to CRE TECHNOLOGY the file for the modification of the language; - Parameters report: command to create a printable list of the parameters; - Actions: a) Synchronize date: command to store the date and time of the PC inside the controller; b) Alarms reset: command to reset the actual active alarms on the controller. 5/11
6 2-3.2 Hardware section The hardware section is composed by: a) I/O status: section to visualize the measures, and the status (green light when active, red light when not active) of the inputs, outputs and led indications. b) Settings: contains the time during which the measures must remain fixed to be revealed in the statistics pages. c) Instruments curve: dedicated sections to set the customized curves I/O status In this section you will see all the analog measures, the status of the digital inputs and outputs, the measures via Canbus and the status of the led indications. The data are not requested to the controller in real time. To see all the actual measures and status press Load from Device Curves customization In the sections: a) Oil pressure b) Water temperature c) Fuel level It s possible to set the desired curves of the instruments. The X values are preset and represent the value that you will see on display (oil pressure, water temperature or fuel level). The VDO, VEGLIA and DATCON values cannot be changed and represent the resistance (ohm) values correspondant to the X point on the left. The CUSTOM values can be modified to create the desired curve. After the modification, it s possible to: - Save the curve on the controller: press Write on device -> the custom curve of the instrument will be set in the controller. For example, if you modified the fuel level curve, pressing write on device, the new curve will be stored as a custom curve for the fuel level. To activate it, go to Fuel setup in the ACGEN2.0/TCGEN2.0 controller, and modify the parameter A (Analog tool type) to Custom. For the oil pressure, go to Oil setup in the ACGEN2.0/TCGEN2.0 controller, and modify the parameter A (Analog tool type) to Custom. For the temperature, go to Temperature setup in the TCGEN2.0 controller, and modify the parameter A (Analog tool type) to Custom. - Print the curve: press Print - Export the curves in a.ai file: press Export - Import the curves from a.ai file: press Import Export function is very useful to save different files with all the possible curves. Import function can be used to load one of the desired curves, depending on the sensor used on the machine. 6/11
7 2-3.3 Program section The program sections contains all the programmation menus, with order and numeration as in the ACGEN2.0/ ICGEN2.0/TCGEN2.0 controller. The available sections are: - Programmation menus (from M1 to M8.5); - Fx Virtual I/O: it permits to modify the functions associated to the programmable inputs and outputs; - Alarms list: it permits to modify the parameters of all the alarms; - Messages log: section to visualize the events log of the controller; - Datalogger: section to save the desired measures in a dedicated memory; Program menus C D E A B All the menus from M1 to M8.5, except for the alarms and the I/O programmation, can be found in this section. When you open one of the menus you will see all the values actually stored in the ACGEN2.0/ICGEN2.0/TCGEN2.0. It s possible to load the default values of the controller, pressing Project default values (E). In this case all the parameters that differ from the default are highlighted in orange, and you will see the default value (A). To change a parameter, click on the value that you want to modify and change it as you prefer. To confirm it, press Enter on your keyboard. The parameter will be immediately highlighted in green (B). To complete the downloading of the modified parameters, press Write on device (D). NOTE: only the parameters highlighted in green will be downloaded in the controller. So, if you loaded the project default values with the button Project default values, to download them in the controller, press Enter on all of them, so that they will be highlighted in green, before pressing Write on device. The parameters are not read from the controller in real time, so it s possible to load them in any moment pressing Load from device (C). NOTE: If you change the selected menu, all the modifications (green and orange parameters) will not be saved. 7/11
8 Fx Virtual I/O This section allows the programmation of all the programmable inputs and outputs. When you open this menu you will see all the values actually stored in the ACGEN2.0/ICGEN2.0/TCGEN2.0. It s divided in 2 parts: - Input programmation (A): all the possible functions that can be associated to the digital inputs of the controller are listed. For each of them it s possible to select the input dedicated to that function. - Output programmation (B): all the programmable outputs of the controller are listed. For each of them it s possible to select the function for that output. A B It s possible to load the default values of the controller, pressing Project default values (E). The data are not requested to the controller in real time. To see all the actual values press Load from Device (C). To complete the downloading of the modified parameters, press Write on device (D). NOTE: The parameters loaded with Project default values are not automatically stored in the controller. You need to press Write on device to write them in the ACGEN2.0/ICGEN2.0/TCGEN Alarms list This section permits the modification of all the parameters of the alarms. A part from all the parameters that you can set also directly from the controller, there is a parameter settable only by CRE MONITOR: Triggers datalogger: if True, the alarm forces the acquisition of a sample, if the datalogger function is activated. A B C To complete the downloading of the modified parameters, press «Write on device» (A). 8/11
9 Messages log If you select «Messages log» you have access to events list stored on the board. All events are stored with date and time, with the message of explanation and a symbol that identifies if the message is a warning or an information; The events log can be reset by CRE MONI- TOR with the button Clear. It s also possible to print the events list with the Print button Data-logger function You can set the dedicated part of the memory for the data-logger function. The parameters, inside PROGRAM M7.3 Datalogger (dedicated menu not visible in the ACGEN2.0/ICGEN2.0/TCGEN2.0 controller), are: Sampling time ( s): you can program the number of seconds to detect datalogger values. Use buffer: if programmed at False, the memory will be filled FLAT MODE: each sampling timer cycle will trigger a dataacquisition from datalogger; if programmed at True the memory will be filled BUFFER MODE: samples are stored insidebuffered 20% of total capacity; when this temporary partition is complete, the average value of samples is saved inside 95%partition and the buffer is cleared to restart the sampling procedure. When a special alarm events happens, the whole buffer is stored inside 95% partition to have a more detailed understanding of the problem. Enable sampling: if True, the datalogger function is enabled and ready. The data-logger section can be found inside the Program section. You can choose which of the available measures must be saved in the data-logger memory. Then, you can make the following actions: Press Load from device (A) to send data request to connected ACGEN2.0/ICGEN2.0/TCGEN2.0, if data-logger function is enabled, data samples will be received and shown within few seconds; Press Export for Excel (C) to export all the data samples into an Excel compatible file. This way you can create trend graphics and stats; Press Clear data (B) to clear the data-logger memory. 9/11
10 The available variables saved inside datalogger memory are: POS. NAME DESCRIPTION 1 VGE L1-L2 (v) Generator phase 1 voltage 2 VGE L2-L3 (v) Generator phase 2 voltage 3 VGE L3-L1 (v) Generator phase 3 voltage 4 VGE L1-n (v) Generator line 1 voltage 5 VGE L2-n (v) Generator line 2 voltage 6 VGE L3-n (v) Generator line 3 voltage 7 F Ge (Hz) Generator frequency 8 VM L1-L2 (v) Mains phase 1 voltage 9 VM L2-L3 (v) Mains phase 2 voltage 10 VM L3-L1 (v) Mains phase 3 voltage 11 VM L1-n (v) Mains line 1 voltage 12 VM L2-n (v) Mains line 2 voltage 13 VM L3-n (v) Mains line 3 voltage 14 F M (Hz) Mains frequency 15 IL1 (A) Phase 1 current 16 IL2 (A) Phase 2 current 17 IL3 (A) Phase 3 current 18 PTot (kw) Total active power 19 STot (kva) Total apparent power 20 QTot (kvar) Total reactive power 21 PF Total power factor 22 Fuel level (%) Fuel level percentage 23 Consumption (Lt/h) Fuel consumption (last minute average) 24 V Bat. (v) Battery DC voltage 25 RPM Engine speed 26 Last ref. (%) Last fuel refilling percentage 27 Oil pressure (bar) Engine oil pressure 28 Engine temp. ( C) Engine water temperature 29 Last alarm Last alarm ID 30 Work hours (h) Engine total work hours Example of an excel graph created with the exported data: Export Selecting the «Export» section, it s possible to save of any parameter or measurement in a excel file. Press the «...» button to create a.csv file that will contain the data. Press «Add» to open a window for the choice of parameter/measure that you want to monitor. You can repeat the operation to add any number of parameters/measures. The chosen variables are shown in the «export variables» field. When you press «export», CRE MONITOR save the state of the variables in the.csv file, showing the date and time in the first column, and the value of the variables in the chosen order in the next columns. Every time you press «export», CRE MONITOR adds a row in the.csv file 10/11
11 CRE TECHNOLOGY 130 allée Charles-Victor Naudin Zone des Templiers Sophia-Antipolis BIOT FRANCE Phone: +33 (0) Fax: +33 (0) Website: Technical support: +33 (0) (office hours: 8.30AM - 12AM / 2PM - 6PM GMT +1) [email protected] SKYPE: support-cretechnology.com Chek our entire distributors list around the world on tab «DISTRIBUTORS» CRE TECHNOLOGY retains all copyrights in any text, graphic images and softwares owned by CRE TECHNOLOGY and hereby authorizes you to electronically copy documents published herein solely for the purpose of transmitting or viewing the information. 11/11
SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
GE Security. FHSD Monitor / Web Server user manual
GE Security FHSD Monitor / Web Server user manual version 1-0 / november 2004 http://www.geindustrial.com/ge-interlogix/emea 2004 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the
RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units
I123 GB 1207 RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units CUSTOMIZATION SOFTWARE MANUAL List of contents Introduction... 2 Main window... 3 Device model selection... 3 Transmission of data
Monnit Wi-Fi Sensors. Quick Start Guide
Monnit Wi-Fi Sensors Quick Start Guide Inside the Box You should find the following items in the box: Monnit Wi-Fi (MoWi ) Sensors 2 x AA Batteries for Each MoWi Sensor Quick Start Guide Note: A MoWi USB
Monitoring Network DMN
Monitoring Network DMN User Manual Table of contents Table of contents... 2 1. Product features and capabilities... 3 2. System requirements... 5 3. Getting started with the software... 5 3-1 Installation...
ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems
ViewPower User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview... 2 1.1. Introduction...2 1.2. Structure...2 1.3. Applications...2 1.4. Features...2
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
Kurz MODBUS Client User s Guide
Kurz MODBUS Client User s Guide Introduction The Kurz MODBUS Client program can be used to demonstrate how the Kurz MFTB and MFTA Series products can be used in a MODBUS protocol network. The program is
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
Infinity C Reference Guide
1 2! Infinity C Reference Guide Table of Contents Components... 1 Hardware Setup... 5 SmartDrive Configuration... 12 Startup... 15 Login... 16 System Configuration... 19 DICOM Setup... 20 Monitoring Status...
mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start
mysensors Information to Users mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant
User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720
User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller Manual version : v1.00 Networking and MIS Manual Dryer controller Page 1 of 16 Document history Preliminary version
USB GSM 3G modem RMS-U-GSM-3G. Manual (PDF) Version 1.0, 2014.8.1
USB GSM 3G modem RMS-U-GSM-3G Manual (PDF) Version 1.0, 2014.8.1 2014 CONTEG, spol. s r.o. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted or stored in
User s Guide for version 5 Page
Network Management Interface Catalog VPi 32.15E For use with these ATS products: 7000 & 4000 Series (Group 5 Controller) Series 300 (Group 1 Controller), and 940, 962, 436, 434, 447, 448 (Group 6A/7A Control
Infinity 2020 Perimeter Intrusion Detection System
Infinity 2020 Perimeter Intrusion Detection System User Guide: Network Application Your First Line of Defense 1 Infinity 2020 Perimeter Intrusion Detection System Table of Contents Section 1: Getting Started...
Medical Vacuum Systems-PXMI
Medical Vacuum Systems-PXMI Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing
Datalogger Graph Software Help
Datalogger Graph Software Help Version 2.0, August 07, 2007 For additional information refer to the user guide included on the supplied program disk. TABLE OF CONTENTS Installing Graph Software....2 Installing
Table of Contents MONITORING SOFTWARE USER MANUAL
Table of Contents MONITORING SOFTWARE USER MANUAL 1.Installations & Settings... 2 1.1. Note... 2 1.2. Installation... 2 1.3. Un-install EnerSolis Monitoring Software from Your Computer 6 2. Function Explanations...
User Manual Software for DSL Digital Speed Switch
User Manual Software for DSL Digital Speed Switch Software version from 1.0.1 Baumer Hübner GmbH Max-Dohrn-Str. 2+4 D-10589 Berlin Phone +49 (0)30 690 03-0 Fax +49 (0)30 690 03-104 [email protected]
WAVES. MultiRack SETUP GUIDE V9.80
WAVES MultiRack SETUP GUIDE V9.80 1 Table of Contents 1. Overview... 3 2. Basic Requirements... 3 3. Software... 4 4. Required Waves Licenses... 4 5. Installing MultiRack... 5 6. MultiRack Native... 6
Guide to Installing BBL Crystal MIND on Windows 7
Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP
About This Guide SolarEdge Configuration Tool Software Guide. About This Guide
About This Guide 3 About This Guide This user guide is intended for Photovoltaic (PV) system owners, installers, technicians, maintainers, administrators and integrators who are authorized to configure
Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software
Manual EN Appendix Blue Solar PWM Pro setup and monitoring software EN Appendix Contents 1. Region and language settings 2 2. Download the software 2 3. UnRAR the software 2 4. Install the software 3
mysensors mysensors Wireless Sensors and and Cellular Gateway Quick Start Guide Information to Users Inside the Box
mysensors mysensors Wireless Sensors and and Cellular Gateway Quick Start Guide Information to Users The mysensors wireless products referenced in this Quick Start Guide have been tested to comply with
Table Of Contents. System Monitoring... 14 System Monitoring Display...14 Monitoring Zones...15 About Areas (partitions)...15 Area Status Display...
Quick Start Table Of Contents Getting Started... 2 NEware Editions...2 Installing NEware...3 Installing Languages...3 Connecting to NEware...3 Changing Your IP100 Password...4 User Codes... 5 Master Feature...5
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
NOVA MULTI-MONITORING SOFTWARE. Instruction Manual
NOVA MULTI-MONITORING SOFTWARE REMOTE OPERATION Precision Digital Corporation s Nova Multi-Monitoring software allows for the operation of common Nova control features remotely from a PC. Up to 30 Nova
Software version 1.1 Document version 1.0
Software version 1.1 Document version 1.0 1 RDNET PROTOCOL OVERVIEW... 2 1.1 Network description... 2 1.2 Connection topology... 2 2 SOFTWARE BASIC OPERATIONS... 3 2.1 Main View elements... 3 2.2 Scanning
POWERED BY BLUE EARTH
M A N U A L POWERED BY BLUE EARTH BLUEEARTHEPS.COM CONTENTS - INTRODUCTION... INTRODUCTION SUMMARY FEATURES - USER MANUAL... APPLICATION INSTALLATION MAC COMPUTER INSTALL WINDOWS COMPUTER INSTALL - LOGIN...
Emerson Smart Firewall
DeltaV TM Distributed Control System Product Data Sheet Emerson Smart Firewall The Emerson Smart Firewall protects the DeltaV system with an easy to use perimeter defense solution. Purpose built for easy
INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description
INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS stam-irs_en 01/11 STAM-IRS is a dedicated server to be used with the STAM-2 monitoring station which enables receiving transmissions sent via telephone
ViewPower User Manual
ViewPower User Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview... 1 1.1. Introduction... 1 1.2. Structure... 1 1.3. Applications... 1 1.4. Features...
Online Monitoring User Guide
High Resolution Temperature Sensing Strip Online Monitoring User Guide 888.637.3282 www.nerdata.com Page 1 of 26 Contents The Aurora Online Monitoring System... 3 1. Creating an Account on the Aurora Online
Temperature & Humidity SMS Alert Controller
Temperature & Humidity SMS Alert Controller Version 7 [Windows XP/Vista/7] GSMS THR / GSMS THP Revision 110507 [Version 2.2.14A] ~ 1 ~ SMS Alarm Messenger Version 7 [Windows XP/Vista/7] SMS Pro series
Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts
Rubbermaid Medical Solutions Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts REVISED FEBRUARY 25, 2010 Filename: Cart Interface Installation & Control Board
ABUS WIRELESS ALARM SYSTEM
ABUS WIRELESS ALARM SYSTEM These installation instructions are published by Security-Center GmbH & Co. KG, Linker Kreuthweg 5, D-86444 Affing/Mühlhausen. All rights including translation reserved. Reproductions
ThermochronWM22 Application for Windows Mobile Getting Started. Step 1: Install PC Applications... 2. Step 2: Install USB Adapter...
ThermochronWM22 Application for Windows Mobile Getting Started Step 1: Install PC Applications... 2 Step 2: Install USB Adapter... 2 Step 3. Setup Microsoft ActiveSync On your PC... 2 Step 4: Copy the
[FAQ] Troubleshooting Access Control Issues
[FAQ] Troubleshooting Access Control Issues Article ID: GV4-14-06-16-t Release Date: 06/16/2014 Applied to GV-ASManager GV-AS Controller GV-Reader Summary When you encounter problems with GV-ASManager,
KCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7
KCU-02 Monitor Software Installation User Manual For Windows XP and Windows 7 Headquarters : No.3, Lane 201, Chien Fu ST., Chyan Jenn Dist., Kaohsiung, TAIWAN Tel : + 886-7-8121771 Fax : + 886-7-8121775
This document is intended to make you familiar with the ServersCheck Monitoring Appliance
ServersCheck Monitoring Appliance Quick Overview This document is intended to make you familiar with the ServersCheck Monitoring Appliance Although it is possible, we highly recommend not to install other
WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F
Wireless Asset Monitoring - Local Food Safety Software BA/WAM-L-F Software Installation and User Guide System Overview The BAPI Wireless Asset Monitoring Local (WAM Local) Software receives temperature
Cyberex BCM-SFCM Configurator/Monitor User's Manual
BRANCH/SUBFEED CIRCUIT MANAGEMENT Cyberex BCM-SFCM Configurator/Monitor User's Manual Updated: 04/01/13 Thomas & Betts Power Solutions 5900 Eastport Boulevard Richmond, VA 23231-4453 Tel: 800-238-5000
User s Manual. Management Software for Uninterruptible Power Supply Systems
PowerShield NetGuard User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. NetGuard Overview...2 1.1. Introduction...2 1.2. Structure...2 1.3. Applications...3
The data between TC Monitor and remote devices is exchanged using HTTP protocol. Monitored devices operate either as server or client mode.
1. Introduction TC Monitor is easy to use Windows application for monitoring and control of some Teracom Ethernet (TCW) and GSM/GPRS (TCG) controllers. The supported devices are TCW122B-CM, TCW181B- CM,
The overall WPT Green Box installation procedure includes: Setting up the WPT Green Box Accessing the WPT Green Box to confirm connectivity
1. Overview The Cypress Envirosystems Wireless Pneumatic Thermostat (WPT) retrofits an existing pneumatic thermostat to provide Direct Digital Control (DDC) like zone control functionality at a fraction
SA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
LTM-1338B. Plus Communications Manual
LTM-1338B Plus Communications Manual 2000. Best Power, Necedah, Wisconsin All rights reserved. Best Power The System Setup option from the Main Menu on the front panel is passwordprotected. The default
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate
EGCP-3 LS 8406-113 Revision L. Explanation of Software Changes Made for the EGCP-3 LS Control. Application Note 51294
EGCP-3 LS 8406-113 Revision L Explanation of Software Changes Made for the EGCP-3 LS Control Application Note 51294 WARNING DANGER OF DEATH OR PERSONAL INJURY WARNING FOLLOW INSTRUCTIONS Read this entire
Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen
Equipment, facilities, and service networks for data collection/logging, data transfer via e-mail/website, and system streamlining can be established without special knowledge. Energy saving system in
Amcrest 960H DVR Quick Start Guide
Amcrest 960H DVR Quick Start Guide Welcome Thank you for purchasing our Amcrest 960H DVR! This quick start guide will help you become familiar with our DVR in a very short time. Before installation and
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Version: 1.4 Table of Contents Using Your Gigabyte Management Console... 3 Gigabyte Management Console Key Features and Functions...
Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos
Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos HMS Industrial Networks AB Page 1 (37) History Revision Date Description Responsible 1.11 2012-09-26 Typos SDA
KCU Communication. PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules. System requirement: Windows XP or above
KCU Communication PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules System requirement: Windows XP or above KCU Communication PC Software User Guide TABLE OF CONTENTS SECTION
Short Manual Intellect v.4.7.6 SP2 module Unipos Contents:
Short Manual Intellect v.4.7.6 SP2 module Unipos Contents: 1. Software Installation... 2 2. Hardware Configuration... 12 3. System Dispatching... 14 3.1. Create dispatching objects... 14 3.2. Graphical
Application & Quick-Start Guide
Model: CRMWIC Web Intelligent Controller 1 This document will illustrate various ways to connect and use a CRM-WIC as well as programming examples. When connecting CRM-WIC, the installer has several interface
User Manual V1.0. Remote Software
User Manual V1.0 Notice: The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products. All specifications are therefore subject to change
NortechCommander Software Operating Manual MAN-00004 R6
NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
IPRS-7 IP/GPRS PC Receiver Software Quick Start V1.2
IPRS-7 IP/GPRS PC Receiver Software Quick Start V1.2 Overview Introduction Before You Begin Installation The IPRS-7 Main Page Configuring the IPRS-7 (IPRS-7 splash screen pictured) Introduction The IPRS-7
PowerShield SNMP Adaptor
PowerShield SNMP Adaptor This manual describes the setup and operation of the PowerShield SNMP adaptor for the Sentinel battery monitoring system 6300-079A SNMP User Manual Page 1 of 9 1. Connecting the
KM Metering Inc. EKM Dash 1.8.3.0 User Manual. EKM Metering Inc. www.ekmmetering.com [email protected] (831)425-7371
EKM Dash 1..3.0 User Manual The EKM Dash is our desktop software solution for your meter data management. It is intended to give you the tools to easily visualize, log, email, and export your data in a
User Manual WatchPower
User Manual WatchPower Management Software for Inverter Table of Contents 1. WatchPower Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install and Uninstall... 1 2.1. System Requirement...
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers. OMEGALOG Help Page 2 Connecting Your Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data Page 11 Downloading
UPS Monitoring Software. User manual Borri Power Guardian
UPS Monitoring Software User manual Borri Power Guardian For Microsoft Windows 8 Microsoft Windows Server 2012 Microsoft Windows 7 Microsoft Windows Server 2008 R2 Microsoft Windows VISTA Microsoft Windows
OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com
OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:
SecureLinx Spider Duo Quick Start Guide
SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...
STIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
32 Transferring Projects and Data
32 Transferring Projects and Data This Chapter explains how to transfer GP-Pro EX project files to the GP and how to transfer the project files stored on the GP to your PC. Please start by reading 32.1
SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE
SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE Equipment Software Manufacturer Survey meter РМ1405 "РМ1405 Software" Polimaster Copyright Polimaster 2015. All rights reserved. According Copyright protection
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
User's Reference Guide for PowerAlert UPS Management Software Version 10.2 for Windows
User's Reference Guide for PowerAlert UPS Management Software Version 10.2 for Windows 1111 W. 35th Street Chicago, IL 60609 USA (773) 869-1234 www.tripplite.com Table of Contents A QUICK GUIDE TO POWERALERT
Remote monitoring of Millenium 3 Logic Controller using Netbiter EasyConnect EC-220 & Netbiter Argos
Remote monitoring of Millenium 3 Logic Controller using Netbiter EasyConnect EC-220 & Netbiter Argos (Remote monitoring of data in the Millenium 3 using SL-In/SL-Out function blocks) Your partner for industrial
IP Power Stone 4000 User Manual
IP Power Stone 4000 User Manual Two Outlet Remote AC Power Controller Multi Link, Inc. 122 Dewey Drive Nicholasville, KY 40356 USA Sales and Tech Support 800.535.4651 FAX 859.885.6619 techsupport@multi
Network Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
EGCP-3 MC 8406-114 Revision H Software 5448-145 Revision F. Explanation of Software Changes Made for the EGCP-3 MC Control. Application Note 51298
EGCP-3 MC 8406-114 Revision H Software 5448-145 Revision F Explanation of Software Changes Made for the EGCP-3 MC Control Application Note 51298 WARNING DANGER OF DEATH OR PERSONAL INJURY WARNING FOLLOW
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started Contents StrikeRisk v6.0 Introduction 1/1 1 Installing StrikeRisk System requirements Installing StrikeRisk Installation troubleshooting
T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: 2004-07-16 Version 1.0
T-BOXN12R You can make it wireless First steps with T-BOXN12R Date: 2004-07-16 Version 1.0 Content 1. Purpose of this document... 3 2. T-BoxN12R overview... 4 3. First step... 5 3.1. Preparing your workshop
Hydras 3 LT Quick Start
Catalog Number 6234218 Hydras 3 LT Quick Start SOFTWARE MANUAL December 2005, Edition 2 Hach Company, 2005. All rights reserved. Printed in the U.S.A. Catalog Number 6234218 Hydras 3 LT SOFTWARE MANUAL
R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement
I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
User s Manual. Management Software for Inverter
WatchPower User s Manual Management Software for Inverter Table of Contents 1. WatchPower Overview... 2 1.1. Introduction... 2 1.2. Features... 2 2. WatchPower Install and Uninstall... 2 2.1. System Requirement...
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Ultra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
BTMPico Data Management Software
BTMPico Data Management Software User Manual Version: 1.3 for S/W version 1.16F or higher 2013-04-26 Page 1 of 22 Table of Contents 1 Introduction 3 2 Summary 5 3 Installation 7 4 Program settings 8 5
DVR-4TL/8TL/16TL Setup Guide
Package Content DVR-4TL/8TL/16TL Setup Guide Inspect the DVR s packaging. Make sure that the DVR-4TL/8TL/16TL is packed properly. Remove all items from the box and make sure it contains the following items.
WebMeter Internal Web Server Feature
70072-0116-10 TECHNICAL 12/2007 WebMeter Internal Web Server Feature Several Ethernet equipped PowerLogic ION meters offer WebMeter capability, allowing you to view meter data and perform basic meter configuration
Status Monitoring. Using Drivers by Seagull to Display Printer Status Information WHITE PAPER
Status Monitoring Using Drivers by Seagull to Display Printer Status Information WHITE PAPER Contents Printer Communications 3 Drivers by Seagull 3 The Seagull Status Monitor 4 Important Benefits 4 Viewing
Quick Installation and Setup for WinPower Software
Quick Installation and Setup for WinPower Software A. On the WinPower Installation menu, simply follow on-screen instructions and key in the software serial number. The installation will be automatically
User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting
Features Reference About Unified Communication System Before Using This Machine Starting a Meeting What You Can Do During the Meeting Leaving a Meeting Managing Address Book Changing Network Configuration
Quick Start Guide NVR DS-7104NI-SL/W NVR. www.hikvision.com. First Choice For Security Professionals
Quick Start Guide NVR DS-7104NI-SL/W NVR NOTE: For more detailed information, refer to the User s Manual on the CD-ROM. You must use your PC or MAC to access the files. www.hikvision.com Quick Start 1.
DCS 6000. DCS 6000 Digital Conference System Firmware Upgrade & Feature License Key Manual. Upgrade Manual. Digital Conference System
DCS 6000 Upgrade Manual Digital Conference System DCS 6000 Digital Conference System Firmware Upgrade & Feature License Key Manual Danish Interpretation Systems DIS Copyright 2009 DIS DCS6000 Upgrade Manual
Installation and Operation Manual Portable Device Manager, Windows version
Installation and Operation Manual version version About this document This document is intended as a guide for installation, maintenance and troubleshooting of Portable Device Manager (PDM) and is relevant
About This Guide SolarEdge Configuration Tool Software Guide. About This Guide
Version 2.0 About This Guide 2 About This Guide This user guide is intended for Photovoltaic (PV) system owners, installers, technicians, maintainers, administrators, and integrators who are authorized
JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP
AZI P/N 700-0042-B Last update May 2009 USER MANUAL JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP May 2009 ARIZONA INSTRUMENT LLC 3375 N Delaware Street Chandler,
If you need additional assistance please contact our Technical Support Center at 24 hours a day, 7 days a week.
Cisco SPA 2100 Phone Adapter Installation Manual Index Installation of the Cisco SPA 2100 Phone Adapter to NationPhone P. 1 Index, before you begin, and what is included P.2 Installing the NationPhone