Chapter 9. Bonding and Grounding



Similar documents
STREETLIGHT SYSTEM GROUNDING AND BONDING

TC Grounding and Bonding for Telecommunications Systems

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

Electrical Grounding. Appendix C

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

800 Communications Circuits

Grounding & Bonding Why it is done And How to Install Properly

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

Title: Grounding and Bonding Rev-01

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Video Camera Installation Guide

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

DPS Preliminary Review: Verizon FIOS Customer Premises Installation NEC Compliance Issues

No Phone Line II-48 System

GENERAL ELECTRICAL REQUIREMENTS

Please check with your local inspection authority for any additional requirements before installation.

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

TABLE OF CONTENT

PXL-250: Network Wiring

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

Electrical Code Regulation

David Brender Copper Development Association Inc. Miramar, March 8, 2013

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

How Much Voltage Drop Is Acceptable?

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

Voltage Drop (Single-Phase)

Multiple Meter Installation Amperes Per Position -Single Phase, Self-contained

Grounding Practice at Data and Communications Centers. David Brender, P.E., CPQ National Program Manager Copper Development Association Inc.

BASIC NEC CODE RULES AND DESIGN PRACTICE

PORTABLE GENERATORS AND OSHA CONSTRUCTION REGULATIONS

6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20

Security Cameras, CATV, GPS & Satellite Protection. White Paper

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

County of Riverside Building and Safety Department

City of Riverside Building & Safety Division Phone: (951)

Current Probes. User Manual

IRRIGATION PUMPING Table of Contents - Section 900

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

Line Loss WSDOT Winter 2008 BZA

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

Grounding and Bonding Against Static Electricity. Jon Koppari, CSP, MS Occupational Safety and Health Instructor OSHA Training Institute

Questions and Answers for Heating and A/C Contractors

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

LDG DTS-4/4R Desktop Coaxial Switch / Remote

CITY OF LOS ANGELES CALIFORNIA

1. Franklin Rod Performance 2. LEC/DAS Performance

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

CHAPTER 2 EXAMPLES AND TABLES

How To Plan Out An Array Of Solar Panels

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

November Stray Voltage Test Procedure for Electrical Contractors

Air Conditioner Water Heater Model ACWH18

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

HDTV. Amplified Indoor Outdoor Antenna. indoor outdoor. 10 db Amplification. Paintable. Versatile TERRESTRIAL VHF UHF

SECTION 22 LIGHTNING PROTECTION SYSTEM

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

The Service Entrance. Technical Terms Drip loop Insulator Meter Meter enclosure

Guidance on Proper Use of EXTENSION CORDS, POWER STRIPS & SURGE PROTECTORS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

ELECTRICAL INSPECTION BULLETIN (Effective )

Power Separation Guidelines for SYSTIMAX Installations

AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

I = V/r P = VI. I = P/V = 100 W / 6 V = amps. What would happen if you use a 12-volt battery and a 12-volt light bulb to get 100 watts of power?

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Policy and Guidelines for Electric Service

Specifications for Lightning Protection. ASAE Engineering Practice

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

June July 18, of 7

Mobile Home Pre-Inspection Checklist

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

ANI Instruction Manual DIGITAL INDOOR/OUTDOOR TV ANTENNA OMNI-DIRECTIONAL WITH AMPLIFIER INTRODUCTION:

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

Electrical Service Guidelines

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Voltage Loss Formula s

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

EZ-48-3AB Weather Station Mounting Tripod and Mast

Transcription:

Chapter 9 Bonding and Grounding

Objectives Describe why the cable should be bonded Describe bonding and grounding procedures Define Bonding and Grounding Explain Safety Benefits and intent of bonding and grounding a cable drop system.

Ground: Ground Versus Bond a conducting connection, whether intentional or accidental, between an electrical circuit or equipment and the earth, or to some conducting body that serves in place of the earth. NEC Article 100 Grounding is the establishment of an effective electrical ground to earth. Accomplished by connecting wires and hardware to an appropriate ground In most cases, this ground is accomplished by driving an 8 foot copper or copper/steel rod (grounding electrode) into the earth Usually placed by power utility company

Ground Versus Bond Bonding: the permanent joining of metallic parts to form an electrically conductive path, that will ensure electrical continuity and the capacity to conduct safely any current likely to be imposed. NEC, Article 100 In the drop system, installers will usually bond the drop. Very rarely do they ground a drop. Bonding is the way all conductive cables and equipment are continuously connected.

Ground Versus Bond Once the utility power ground rod is properly placed, all connections to is are considered bonded to a common ground However it is not necessary to bond strictly to the ground rod it can be done to any portion of an electrical system that is already properly bonded to an effective ground In the situation below the medal conduits are grounded because they connect to the medal cabinet which is connected to the power grounding conductor which is bonded to the ground rod

Electrical Code Requirements The NEC is recommended practices, but not actual law Communities must adopt and then it is enforceable by law

Safety Benefits Grounding provides a termination point for currents that might be present, or in the event that metallic surfaces are inadvertently energized. Metallic surfaces include: Faulty equipment-tvs, Set top terminals, Direct contact with high voltage wires and equipment Induced voltages from high voltage in close proximity, static and lightning Any electrical device can become faulty and produce electrical voltages

Safety Benefits Bonding equalizes and limits the differences in potential between conductors. Electrons take the path of least resistance If an individual simultaneously touches two separate wiring systems (power, cable or telephone) that have different ground potentials---unwanted current will flow though that individual to the second system The individual becomes the conducting path---potential deadly. For this reason separate wiring systems in a house are bonded to a common ground. Broadband, power and telephone bonded to same ground

Difference of Potential

Safety Benefits Primary reason for bonding and grounding is to protect human life Technician as well as home owner Secondary reason is protection of equipment Electronic Equipment can be damaged Shorted electrical circuits and electrical fires can result from improper bonding and grounding

Bonding Location Choose where to bond the security box for the bonding block or bonded splitter: Considerations: Proximity of the premises power ground or utility cabinets Available authorized bonding hardware Cable TV outlet locations Customer preferences

Locating Security Box As close to power as possible

Approved Bonding Hardware

Examining Bonding Options Bonding the broadband drop to the Utility Power Grounding Conductor To grounding rod

Bonding to Utility Ground Rod Bonding to utility grounding electrode (rod) Examples of clamps for bonding to ground rod

Bonding to Electrical Meter Cabinet Meter Pan Bonding Connector

Bonding to Electrical Meter Cabinet Bonding to electric meter cabinet using panel lid bonding connector

Bonding to Electrical Meter Cabinet Bonding to electric cabinet with meter box bar clamp

Unacceptable Bonding practices Natural Gas piping systems Telephone grounding rod, clamp, wire or equipment Outdated cable TV ground rod Sharing the power company s grounding clamp Outdated cable TV ground rod, usually ½ inch in diameter and 3 feet in length.

What s wrong with this picture?

Good Ground?

Green Tax says: DO NOT REMOVE GROUNDING WIRE CALL CABLE TV

Grounds Grounds can be; Intentional Of low impedance that has enough current carrying capacity to prevent buildup of voltage. Accidental Usually referred to as short or short circuit. A path with little or no resistance to ground created between circuit and ground. ESD, example Intentional Grounds protect equipment, Accidental grounds destroy equipment

Bonding; Equipment Failure CATV and electrical wiring systems are frequently hit by high amplitude, short duration currents from power surges, lightning, and downed power poles These voltage potentials can destroy equipment. If all equipment shares a common ground it can help bleed off these voltages. The VCR cable input can be smoked by voltage spikes when grounding is inadequate.

Bonding Customer Premises Select Bonding Block/Splitter F-81 connecter mounted to a medal block

Inside Security Box Bonded wire attached to Bonding Block Unbonded Splitter for multiple outlets

Inside Security Box 7/16 th wrench used to connect input and output cables to splitter

Bonding Wire NEC Handbook articles 820 & 830 require bonding wire to be: 1. Insulated, 2. Solid copper, 3. Not smaller than No. 14 gauge with current carrying capacity approximately equal to that of the outer conductor of the coaxial drop cable No. 14 wire is the minimum size required for Series 56 and Series 6 drop cables For larger coax No. 12 or 10 AWG (American Wire Gauge) will be required to comply with NEC Select bonding wire with current carrying capacity approximately equal to that of drop cable needed (per NEC Handbook)

Coaxial Cable Current Carrying Capacities The size of the drop wire and its current carrying capacity are directly related. The current carrying capacity of the drop cable must directly correlate to the bonding wire capacity. Note that Series 11 quad-shield cable can carry current from 35-42 amps. To properly bond this cable, No 10 wire is required

Bonding Block A bonding block or grounding block is pictured here One side connects to the Tap cable The other side connects to customer drop The hole is for insertion of the bonding wire This device is usually attached to the outside of the house F-81 connector with attachment for ground.

Bonding Wire Attach the bonding wire to the drop cable by the use of a bonding block or splitter. Insulated with rubber or other insulation and made of copper or other corrosion-resistant conductive material. Identify it with a tag: This bond is not to be removed.

Bonding Wire (cont) Keep it as short and straight as practical Be sure it is at least #14 wire (#12 wire when bonding to the frame of a mobile home) and has a current-carrying capacity equal to or greater that that of the outer conductor of the coaxial cable. Wire gauge table http://www.reade.com/conversion/wire_gauge.html

Bonding Options Detail s pg 9.14 Check with your supervisor (or company policy) for the bonding specifications of the system you maintain. Bonding Options: Customer s electrical service grounding electrode or grounding conductor. Metallic conduit on the load side of the power meter. Metallic conduit between and weather head and meter pan. http://www.lipower.org/residential/safety/powersupply.html Electrically conductive cold water pipe. 5/8 inch, 8 foot ground rod made of copper-clad or galvanized steel.

House Electrical A - Service Drop B - Weatherhead C - Service Mast / Conduit D - Electric Meter E - Main Panel F - 120 Volt Lighting Circuit G - 120 Volt Outlet Circuit H - 240 Volt Oven Circuit I - 120 Volt Outlet Circuit J - Sub-Panel K - "GFCI" Protected Outlet L - 240 Volt Water Heater Circuit

Only acceptable if paint and rust are removed from Metallic Conduit. Many power companies are now using plastic conduit which is unacceptable for bonding.

Not all cable companies will allow this type of bond

If a water faucet is to be used as a ground, it should be verified with a Should VOM. be zero There volts should and less be than no voltage 25 ohms of and resistance a max of 25 ohms of resistance. Notice the spool of wire since the faucet and power meter panel are likely far apart. This will rule out the use of PVC in the water system.

Professional Preferences Always choose to run a large quantity of coaxial cable around the house instead of a large quantity of bonding wire. When two or more buildings have a common service but each one has its own building electrode system, bond each building independently. When only one power branch circuit is supplied and the power service is grounded at the main building (for example a house and a garage), a separate bond at each building is not needed

Conclusion Bonding and grounding is often the final step in the exterior work of an install, but one you have to plan for at the beginning of each install. To do it well, you need to follow procedures, use accepted practices, and be sure your workmanship is excellent.

Links Wire gauge table Grounding Electrode Documenting Cable Wiring Violations Kramer.Firm's Cable Television System Photos Home