Power Outlet Panels. Product Guide

Size: px
Start display at page:

Download "Power Outlet Panels. Product Guide"

Transcription

1 Product Guide Construction and Recreational Vehicle (RV) Power Outlet Panels Vehicle Power (RV) Power Outlet Panels Power Outlet Panels

2 Construction and RV Power Outlet Panels Product Description...1 Application Description...1 Features, Functions, and Benefits...1 Standards and Certifications...1 Product Specifications...2 Product Selection...3 Dimensions...6 Accessories...10 Replacement Parts...11 Vehicle Power (RV) Power Outlet Panels Product Description...12 Application Description...12 Features, Functions, and Benefits...12 Standards and Certifications...12 Newport Camp Mate...13 Park Light...18 Powerhouse...23 Powerhouse Stainless Steel...28 Firehouse...33 Product Description...37 Application Description...37 Features, Functions, and Benefits...37 Standards and Certifications...37 Newport Harbor Mate...38 Hatteras...43 Lighthouse...48 Lighthouse Stainless Steel...53 Firehouse...58 Mariner...62 Admiral...65 Smart Start...67 Mega Yacht PowerPoint...69 Substations...70 POWER OUTLET PANELS PG P.K January I

3 Construction and RV Power Outlet Panels Construction and RV Power Outlet Panels Product Description A Power Outlet Panel (or POP) is a device designed for outdoor service to meet temporary power requirements at construction sites and recreational vehicle (RV) parks. Construction sites and RV parks need to provide a safe and reliable means for users to access electricity and Power Outlet Panels provide the outlets for electrical access. Application Description Power Outlet Panels (POPs) are also sometimes called Temporary Power Panels, Temporary Site Service Equipment or RV (Recreational Vehicle) Panels. When Power Outlet Panels are used at a construction site, they are installed on a temporary basis until electrical power is available at the building. The most common reason for needing a Power Outlet Panel at a construction site is to provide a power source for the contractor s tools. When POPs are used at an RV park, they are installed for more permanent use and serve the purpose of providing power to a vehicle s appliances. Many RV parks now supply users with lighted POPs with TV and telephone jacks. A move towards offering more amenities at RV parks. Figure 1. Power Outlet Panel Features (Surface Mount Unit Pictured) Features, Functions, and Benefits Designed for outdoor service to meet power outlet requirements. Receptacles conform to NEMA and/or ANSI configurations. Includes a factory installed insulated neutral bar. 125 ampere rated meter socket. Factory installed type BR (Non-GFCI) or type GFCB (Ground Fault) circuit breakers. Panels come from the factory completely assembled, prewired with 100 percent copper wire, and tested ready for easy installation. Door swings up and open for user convenience and ease of access to breakers and receptacles. Panels can be bottom fed through knockouts in endwall or top fed using a bolt-on raintight hub. Two-piece deadfront cover allows field wiring without interfering with factory wiring. Lower deadfront cover permits easy field wiring to circuit protective devices. GFI (ground fault interrupter) 1- and 2-pole protection through 50 amperes. Enclosures are manufactured from 16 gauge G90 galvanized steel Pedestal mount style units come standard with loop feed lug assembly that accommodates #6-350MCM cabling. Standards and Certifications cul rated CSA Certified, File Number UL Standard 231 UL File Number E Receptacles conform to NEMA and/or ANSI configurations as specified by the US National Electrical Code (NEC) Note: This product is not service entrance approved percent galvanized steel with baked-on polyester powder coating. Three-point mounting. One-piece case back for metered and unmetered panels. Lighted option for site location and nighttime panel operations. GFI circuit breakers available through 50 amperes (Type GFCB). Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked. Metered units available with meter on top or on bottom. Note: NEMA is a registered trademark and service mark of the National Electrical Manufacturers Association. CSA and UL are federally registered trademarks of the Canadian Standards Association and Underwriters Laboratories Inc. respectively. All other trademarks are property of their respective owners. NEMA 3R construction for rainproof installation. Utility grade metering available for construction site RV park applications. Door swings up and pushes in to lock in the open position. Pull out and push down to close door. Removable upper deadfront cover for easy incoming wire connections to breaker terminals. Lower deadfront cover rotates 90 degrees or can be removed for easy routing of incoming wires or receptacle changeouts. Padlock provisions to prevent unauthorized entry. Units are factory wired and assembled. Units are designed for top or bottom cable entry. 1 POWER OUTLET PANELS PG P.K January

4 Construction and RV Power Outlet Panels Product Specifications The power outlet panels shall be designed for outdoor service to meet temporary power outlet requirements at construction sites and provide high quality, economical power to individual sites at recreational vehicle (RV) parks. RV panels shall have a factory-installed insulated neutral bar. Receptacles and Circuit Protection The circuit protection shall be Eaton s CSA/UL listed full-size type BR or, half-size type DNPL circuit breakers. The receptacles shall be NEMA commercial/ industrial grade and come in a variety of configurations. Ground fault protection can be provided at the 20 ampere NEMA 5-20R receptacle or, at the circuit breaker for all other receptacles. Construction The power outlet panel pedestal shall be of deadfront design and constructed of heavy gauge,100 percent galvanized steel. Bakedon polyester powder coating shall be used for excellent mechanical strength, plus resistance to chalking caused by the sun s ultraviolet rays. The power outlet panel surface and pedestal units shall have NEMA Type 3R rainproof enclosures. Ease of Installation Panels shall ship from the factory completely assembled, prewired with 100 percent copper wire, and tested in accordance with UL Standard 231. Door shall swing up and open for user convenience and ease of access to breakers and receptacles. When required, a means for securing the door in the open position shall be provided. Panels shall be bottom fed through knockouts in endwall or top fed using a bolton raintight hub. Knockouts shall range from 1/2-inch (12.7 mm) to 1-1/2 inches (38.1 mm). #4 14 Cu/Al grounding provisions shall be provided on all panels. Single Receptacle Style Surface Mount Unmetered Style Surface Mount Metered Style Pedestal Mount Unmetered Style POWER OUTLET PANELS PG P.K January

5 Construction and RV Power Outlet Panels Product Selection When quoting or selecting a Power Outlet Panel, the following items should be considered: Unmetered, Metered. Number and type of receptacles (6 standard and 8 twist-lock options). Standard or Ground Fault Circuit Breakers. Additional space for field mounted circuit breakers. Surface, Pedestal, or Back-to-Back Mounting. Table 1. Construction and RV Power Outlet Panel Catalogue Number System CH U 1 N 7 N 4 N P X L TZ Metering Type U = Unmetered M = Metered Left Position Receptacle Type 1 = NEMA 14-50R 3 = NEMA 14-30R 4 = NEMA TT-30R 5 = NEMA 6-20R2 6 = NEMA 5-20R2 7 = NEMA 5-20R2GFI A = NEMA L14-50R B = NEMA L6-50R C = NEMA L5-50R D = NEMA L14-30R E = NEMA L6-30R F = NEMA L5-30R Centre Position Receptacle Type 1 = NEMA 14-50R 3 = NEMA 14-30R 4 = NEMA TT-30R 5 = NEMA 6-20R2 6 = NEMA 5-20R2 7 = NEMA 5-20R2GFI A = NEMA L14-50R B = NEMA L6-50R C = NEMA L5-50R D = NEMA L14-30R E = NEMA L6-30R F = NEMA L5-30R G = NEMA L6-20R H = NEMA L5-20R Blank = No Receptacle Right Position Receptacle Type 1 = NEMA 14-50R 3 = NEMA 14-30R 4 = NEMA TT-30R 5 = NEMA 6-20R2 6 = NEMA 5-20R2 7 = NEMA 5-20R2GFI A = NEMA L14-50R B = NEMA L6-50R C = NEMA L5-50R D = NEMA L14-30R E = NEMA L6-30R F = NEMA L5-30R G = NEMA L6-20R H = NEMA L5-20R Blank = No Receptacle Pedestal Extension TZ = Factory Installed Extension Blank = No Extension Illumination Option L = Lighted Blank = No Lighting Circuit Breaker Interior X = Six Circuit Blank = Four Circuit (Standard) Mounting Style S = Surface Mount P = Pedestal Mount B = Back-to-Back Pedestal Mount G = NEMA L6-20R H = NEMA L5-20R Blank = No Receptacle Circuit Breaker Type Position 1 Circuit Breaker Type Position 2 N = Non-Ground Fault G = Ground Fault Circuit Breaker Type Position 3 N = Non-Ground Fault G = Ground Fault N = Non-Ground Fault G = Ground Fault Not all option combinations are possible. Contact your Eaton sales rep for confirmation of correct catalogue number selection. For receptacle configurations, see table 2. 3 POWER OUTLET PANELS PG P.K January

6 Construction and RV Power Outlet Panels Product Selection Continued Table 2. Standard Receptacle Configurations Catalogue Number Code Blade Arrangement NEMA Designation Description Feeder Circuit Breaker R 50 Amperes, 125/250 Volts, 3-Pole, 4-Wire 2-Pole 50 Amperes R 30 Amperes, 125/250 Volts, 3-Pole, 4-Wire 2-Pole 30 Amperes 4 TT-30R 30 Amperes, 125/250 Volts, 2-Pole, 3-Wire 1-Pole 30 Amperes R2 20 Amperes, 250 Volts, 2-Pole, 3-Wire 2-Pole 20 Amperes R2 20 Amperes, 125 Volts, 2-Pole, 3-Wire (Non-GFI) 1-Pole 20 Amperes R2GFI 20 Amperes, 125 Volts, 2-Pole, 3-Wire (w/gfi) 1-Pole 20 Amperes Table 3. Locking Receptacle Configurations Catalogue Number Code Blade Arrangement NEMA Designation Description Feeder Circuit Breaker A L14-50R 50 Amperes, 125/250 Volts, 3-Pole, 4-Wire, Grounding 2-Pole 50 Amperes B L6-50R 50 Amperes, 125/250 Volts, 2-Pole, 3-Wire, Grounding 2-Pole 50 Amperes C L5-50R 50 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 2-Pole 50 Amperes D L14-30R 30 Amperes, 125/250 Volts, 3-Pole, 4-Wire, Grounding 2-Pole 30 Amperes E L6-30R 30 Amperes, 250 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 30 Amperes F L5-30R 30 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 30 Amperes G L6-20R 20 Amperes, 250 Volts, 2-Pole, 3-Wire, Grounding 2-Pole 20 Amperes H L5-20R 20 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 20 Amperes Breakers used are BR type. POWER OUTLET PANELS PG P.K January

7 Construction and RV Power Outlet Panels Product Selection Continued Table 4. Construction and RV Power Outlet Panel Catalogue Number Selection Examples Mounting Metering Catalogue Receptacle and Circuit Breaker Description Light Factory 2, 4, Dim. Number Left Position Centre Position Right Position Pedestal or 6 Figure Extension Circuit Interior Surface Unmetered CHU1S Receptacle NA 50A, 14-50R NA NA NA NA 2 Circuit Breaker NA NA NA Surface Unmetered CHUDS Receptacle NA 30A, L14-30R NA NA NA NA 2 Circuit Breaker NA NA NA Surface Unmetered CHU4N7NS Receptacle 30A, TT-30R 20A, 5-20R2GFI No NA 2 3 Circuit Breaker BR130 BR120 Surface Unmetered CHUFN6G6GS Receptacle 30A, L5-30R 20A, 5-20R2 20A, 5-20R2 No NA 4 4 Circuit Breaker BR130 BR120 Surface Metered CHM1N7NS Receptacle 50A, 14-50R 20A, 5-20R2GFI No NA 4 5 Circuit Breaker BR250 BR120 Surface Metered CHM1N7N4NSL Receptacle 50A, 14-50R 20A, 5-20R2GFI 30A, TT-30R Yes NA 4 5 Circuit Breaker BR250 BR120 BR130 Pedestal Unmetered CHU4G6GP Receptacle 30A, TT-30R 20A, 5-20R2 No No 4 6 Circuit Breaker GFCB130 GFCB120 Pedestal Unmetered CHU1N7N4NPTZ Receptacle 50A, 14-50R 20A, 5-20R2GFI 30A, TT-30R No Yes 4 6 Circuit Breaker BR250 BR120 BR130 Pedestal Metered CHMAN6GP Receptacle 50A, L14-50R 20A, 5-20R2 No No 4 7 Circuit Breaker BR250 GFCB120 Pedestal Metered CHM1N7N4NPX Receptacle 50A, 14-50R 20A, 5-20R2GFI 30A, TT-30R No No 6 7 Circuit Breaker BR250 BR120 BR130 Back-to-Back Unmetered CHU6G6GB Receptacle 20A, 5-20R2 20A, 5-20R2 No No 4 8 Circuit Breaker GFCB120 GFCB120 Back-to-Back Unmetered CHU4N7N4NBTZ Receptacle 30A, TT-30R 20A, 5-20R2GFI 30A, TT-30R No Yes 4 8 Circuit Breaker BR130 BR120 BR130 Back-to-Back Metered CHM4N6GB Receptacle 30A, TT-30R 20A, 5-20R2 No No 4 9 Circuit Breaker BR130 GFCB120 Back-to-Back Metered CHM1N7N4NBLTZ Receptacle 50A, 14-50R 20A, 5-20R2GFI 30A, TT-30R Yes Yes 4 9 Circuit Breaker BR250 BR120 BR130 5 POWER OUTLET PANELS PG P.K January

8 Construction and RV Power Outlet Panels Dimensions Figure 2. Single Receptacle Style Power Outlet Panel (In [mm]) POWER OUTLET PANELS PG P.K January

9 Construction and RV Power Outlet Panels Dimensions Continued Figure 3. Surface Mount Unmetered Style Power Outlet Panel (Two Circuit Interior) (In [mm]) 6.25 (158.8) 4.25 (108.0) (298.5) Figure 4. Surface Mount Unmetered Style Power Outlet Panel (Four or Six Circuit Interior) (In [mm]) 7 POWER OUTLET PANELS PG P.K January

10 Construction and RV Power Outlet Panels Dimensions Continued Figure 5. Surface Mount Metered Style Power Outlet Panel (In [mm]) Figure 6. Pedestal Mount Unmetered Style Power Outlet Panel (In [mm]) Figure 7. Pedestal Mount Metered Style Power Outlet Panel (In [mm]) 9.50 (241.3) 5.00 (127.0) 6.80 (172.7) 4.30 (109.2) (1320.8) Locking Provision (1130.3) (655.3) (429.3) (558.8) Sealing Provision POWER OUTLET PANELS PG P.K January

11 Construction and RV Power Outlet Panels Dimensions Continued Figure 8. Back-to-Back Mount Unmetered Style Power Outlet Panel (In [mm]) (345.4) 8.60 (218.4) 9.50 (241.3) Locking Provision (434.3) (487.7).75 (19.1) 3.30 (83.8) Figure 9. Back-to-Back Mount Metered Style Power Outlet Panel (In [mm]) (345.4) 9.50 (241.3) 9.90 (251.5) 8.60 (218.4) 9.50 (241.3) (1320.8) Locking Provision (762.0) (1130.3) (1061.7) (655.3) (429.3) (571.5) (558.8) (490.2) Sealing Provision Sealing Provision.75 (19.1) 3.30 (83.8) 9 POWER OUTLET PANELS PG P.K January

12 Construction and RV Power Outlet Panels Accessories Table 5. Construction and RV Power Outlet Panel Accessories 1-Phase 2-Wire 240V AC Catalogue Number CHPEDEXT CHPEDEXTSS CHPADEXT CHTELTV DS075H1 DS100H1 DS125H1 DS150H1 CHFLGTKIT Description Underground Pedestal Extension Underground Pedestal Extension (Stainless Steel) Pad Mounting Bracket Cable TV and Telephone Bracket Rainproof Conduit Hub 0.75 Inch (19.1mm) Rainproof Conduit Hub 1 Inch (25.4mm) Rainproof Conduit Hub 1.25 Inch (31.8mm) Rainproof Conduit Hub 1.5 Inch (38.1mm) Fluorescent Light Kit (Converts A Power Outlet Panel To A Lighted Unit) Pad Mounting Bracket Cable TV and Telephone Bracket Pedestal Extension Conduit Hub POWER OUTLET PANELS PG P.K January

13 Construction and RV Power Outlet Panels Table 6. Construction and RV Power Outlet Panel Replacement Parts Catalogue Number CHPOPMS CHPOPMSN ARP00039CH 1MM5JKOP ARP00035CHJ CHBONDST CHINLENS CHLOOPFDP CHLOOPFDB CHLDFCVR CHLDFCVR1 CHLDFCVR2 CHLDFCVR3 CHLDFCVR4 CHLDFCVR5 CHLDFCVR6 CHLDFCVR7 CHLDFCVR8 CHLDFCVR9 CHLDFCVR10 CHLDFCVR11 CHLDFCVR12 CHLDFCVR13 CHLDFCVR14 CHLDFCVR15 CHLDFCVR16 CHLDFCVR17 CHLDFCVR18 CHUDFCVR CHUDFCVRL CHOUTCVR CHOUTCVRL CHNEUT CHNEUT1 GBK5 GBK10 CHPOPRMC Description Replacement Meter Socket Replacement Meter Socket Replacement Meter Socket (1 Block Assembly Per Kit) 5th Jaw Kit 5th Jaw Kit Bonding Strap and Mounting Hardware Inner Lens for Lighted Power Outlet Panels Loop Feed Lug Assembly for Single Pedestal Loop Feed Lug Assembly for Back-to-Back Pedestal Blank Lower Deadfront Cover Lower Deadfront Cover with Duplex Receptacle Opening Lower Deadfront Cover with Duplex, Duplex Receptacle Opening Lower Deadfront Cover with Duplex, Duplex, Duplex Receptacle Opening Lower Deadfront Cover with Rectangle Receptacle Opening Lower Deadfront Cover with Rectangle, Rectangle Receptacle Opening Lower Deadfront Cover with Rectangle, Rectangle, Rectangle Receptacle Opening Lower Deadfront Cover with Duplex, Rectangle Receptacle Opening Lower Deadfront Cover with Duplex, Rectangle, Duplex Receptacle Opening Lower Deadfront Cover with Rectangle, Rectangle, Duplex Receptacle Opening Lower Deadfront Cover with Round Receptacle Opening Lower Deadfront Cover with Round, Round Receptacle Opening Lower Deadfront Cover with Round, Duplex Receptacle Opening Lower Deadfront Cover with Round, Duplex, Duplex Receptacle Opening Lower Deadfront Cover with Round, Duplex, Round Receptacle Opening Lower Deadfront Cover with Round, Rectangle Receptacle Opening Lower Deadfront Cover with Round, Rectangle, Rectangle Receptacle Opening Lower Deadfront Cover with Round, Rectangle, Round Receptacle Opening Lower Deadfront Cover with Round, Rectangle, Duplex Receptacle Opening Upper Deadfront Cover with Six Breaker Twistouts Upper Deadfront Cover with Provisions for Lighted Option Power Head Outer Cover Power Head Outer Cover with Lens 6-Hole Neutral Assembly with 2/0 Lug 7-Hole Neutral Assembly with 2/0 Lug 5-Hole Ground Bar Kit 10-Hole Ground Bar Kit Replacement Meter Cover For Power Outlet Panels manufactured before December 1, For Power Outlet Panels manufactured after December 1, For Power Outlet Panels with a date code ending in L. For Power Outlet Panels with a date code not ending in L. For Power Outlet Panels ordered after January 1, POWER OUTLET PANELS PG P.K January

14 Vehicle Power (RV) Power Outlet Panels Vehicle Power (RV) Power Outlet Panels Product Description The Vehicle Power (RV) Power Outlet Panel is designed for outdoor service to meet temporary power requirements at campground and recreational vehicle (RV) parks. Campground and RV park sites need to provide a safe and reliable means for users to access electricity and Campground/RV Park Power Outlet Panels provide the outlets for electrical access. Application Description Vehicle Power (RV) Power Outlet Panels are also sometimes called Temporary Power Panels, RV (Recreational Vehicle) Panels, Camping Pedestals. When POPs are used at an RV park, they are installed for more permanent use and serve the purpose of providing power to a vehicle s appliances. Many RV parks now supply users with lighted POPs with TV and telephone jacks. A move towards offering more amenities at RV parks. Features, Functions, and Benefits Designed for outdoor service to meet power outlet requirements. Receptacles conform to NEMA, ANSI, or IEC configurations. Factory installed type QC circuit breakers. Panels come from the factory completely assembled, prewired, and tested, ready for easy installation. Lighted pedestal options include amber or clear lenses with compact fluorescent or LED lamps. Lockable receptacle access doors swing up for user convenience and ease of access to breakers and receptacles. Pedestal style power outlet panels have open bottoms for entry of feeder cabling. Pedestal enclosures are built of a heavy resin with a twopart UV resistant polyurethane coating. Stainless steel models are built from 18 gauge stainless steel and are powder coated to provide a long lasting, maintenance-free finish. Some available factory installed options include hose bibs for water connections; telephone, cable, and internet connections; meter sockets; wireless electronic power metering; and water metering. Custom paint colours are also available in many pedestal styles. Contact your local Eaton sales office for colour availability and pricing. The Firehouse pedestal provides a convenient and eye-catching storage location for an emergency fire extinguisher and life ring for a poolside application. Optional audible and visual alarms signal opening of the extinguisher door or removal of the life ring. Standards and Certifications CSA Certified (Select models) Receptacles conform to NEMA, ANSI, or IEC 309 configurations. POWER OUTLET PANELS PG P.K January

15 Vehicle Power (RV) Power Outlet Panels Newport Camp Mate Product Description The Newport Camp Mate provides many of the features and options of our other full size pedestals, but in a compact self-contained unit. This model provides more mounting options to RV park owners than any other model. It can be mounted to our stainless steel stand, a post, or any wall. It comes standard with a resin housing that will never rust or deteriorate and photocell controlled lighting that can aid in night-time hookups. The Newport Camp Mate is UL listed and comes with a limited lifetime warranty on the housing. This unit is especially suitable for many RV park renovation projects, as well as new RV parks. Features, Functions, and Benefits Photocell controlled 9 or 14- Watt fluorescent light or LED light with amber or clear lens. Lockable weatherproof door that protects receptacles and breakers. Heavy resin housing. Limited lifetime warranty on the housing. Designed to mount on a post, wall, or an optional stand. Loop-feed 1/4-inch copper compression stud bus bars that can accept 2/0 AWG wire for Camp Mate without optional stand. Loop-feed mechanical bus bars that can accept up to 350 kcmil wire for Camp Mate on optional stand. Available Options 36-inch stainless steel stand. 60-inch direct burial aluminum stand. Telephone connection (RJ11). Cable TV connection. High-speed Internet connector (RJ45). Single or dual 1/4-turn brass ball valves (brass T connection) with 3/4-inch hose bibs for water connection. Anti-siphon backflow preventer for the water supply connection. Single-feed mechanical bus bars for up to 350 kcmil wire available with optional stand. Wireless remote reading of electronic kilowatt meter. Factory installed pre-wired circuit breakers for additional electrical loads. Standards and Certifications CSA Certified File POWER OUTLET PANELS PG P.K January

16 Vehicle Power (RV) Power Outlet Panels Product Selection When quoting or selecting a Newport Camp Mate Power Outlet Panel, the following items should be considered: Number and type of receptacles. Lighting wattage, lens colour, control, and electrical protection method. Number of water connections. Number of phone, cable, or internet connections. Surface mount or factory installed stainless steel stand. Electrical bus connection style. Additional factory installed hardwired breakers for other planned loads. Table 7. Newport Camp Mate Power Outlet Panel Catalogue Number System C A Y B U C Light Style & Lens Colour A = 9W, Amber C = 14W, Amber F = None, Amber G = 9W, Clear I = 14W, Clear L = None, Clear S = LED Amber U = LED Clear Photocell Light Control Y = Yes N = No Lighting Protection B = Circuit Breaker F = Fuse Metering Type U = Unmetered D = Digital Electronic Meters R = Receptacles Metered Individually Receptacle 3 0 = No Receptacle 1 = 20A GFCI Duplex Receptacle 2 0 = No Receptacle 1 = 20A GFCI Duplex 2 = 30A 125V 3 = 50A 125V 4 = 50A 125/250V Receptacle 1 0 = No Receptacle 1 = 20A GFCI Duplex 2 = 30A 125V 3 = 50A 125V 4 = 50A 125/250V Not all option combinations are possible. Contact your Eaton sales rep for confirmation of correct catalogue number selection. For receptacle configurations, see table 8. Only available on pedestals with factory installed stand option. Factory Installed Stand 0 = No Stand (Surface Mount) 1 = Stainless Steel Stand Phone, Cable TV, & Internet Connection Options Phone Cable TV Internet A B D E T V W Hardwired Circuit Breakers 0 = None 2 = 20A Double Pole 3 = 30A Single Pole Water Connections 0 = None 1 = Single 3/4 Hose Bib 2 = Dual 3/4 Hose Bib Bus Options C = Single Phase Mechanical Lugs S = Single Phase 1/4 Compression Studs F = Three Phase 1/4 Compression Studs POWER OUTLET PANELS PG P.K January

17 Vehicle Power (RV) Power Outlet Panels Product Selection Continued Table 8. Standard and Locking Receptacle Configurations Catalogue Number Code Blade Arrangement NEMA Designation Description Feeder Circuit Breaker R2GFI 20 Amperes, 125 Volts, 2-Pole, 3-Wire (w/gfi) 1-Pole 20 Amperes 2 TT-30R 30 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 30 Amperes R 50 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 50 Amperes R 50 Amperes, 125/250 Volts, 3-Pole, 4-Wire, Grounding 2-Pole 50 Amperes Table 9. Newport Camp Mate Power Outlet Panel Catalogue Number Selection Examples Mounting Metering Catalogue Receptacle Description Light & Lens Water Phone Factory Number Side 1 Side 1 Side 2 Connections Cable Pedestal Receptacle 1 Receptacle 2 Receptacle 1 Internet Extension Surface Unmetered CAYBU C 50A, 125/250V 50A, 125V 9W, Amber 0 No Surface Unmetered CCYBU201020DC 30A, 125V 20A 125V GFCI 14W, Amber 2 P, C No Surface Metered CGYBD C 50A, 125V 9W, Clear 1 No Surface Metered CAYBD C 30A, 125V 30A, 125V 9W, Amber 2 No Pedestal Unmetered CAYBU C 50A, 125/250V 50A, 125V 9W, Amber 0 Yes Pedestal Unmetered CCYBU201120BC 30A, 125V 20A 125V GFCI 14W, Amber 2 P, I Yes Pedestal Metered CGYBD C 50A, 125V 9W, Clear 1 Yes Pedestal Metered CAYBD C 30A, 125V 30A, 125V 9W, Amber 2 Yes Breakers used are QCR type. 15 POWER OUTLET PANELS PG P.K January

18 Vehicle Power (RV) Power Outlet Panels Dimensions Figure 10. Newport Camp Mate Power Outlet Panel Dimensions (Without pedestal accessory) (In [mm]).12 [3.2] 9.18 [233.0] [267.2] 7.44 [189.1] [263.7] [388.0] [369.0] [327.2] 2.37 [60.3] 1.68 [42.7] 3.40 [86.4] 6.70 [170.2] 1.54 [39.1] 4.02 [102.2] Lighting Assembly Under Removable Cover [263.7] Figure 11. Newport Camp Mate Power Outlet Panel Dimensions with pedestal accessory installed (In [mm]) POWER OUTLET PANELS PG P.K January

19 Vehicle Power (RV) Power Outlet Panels Mounting Figure 12. Newport Camp Mate Power Outlet Panel Pedestal Mounting Dimensions ELECTRICAL AND COMMUNICATIONS ACCESS Ø WATER ACCESS HOLE 17 POWER OUTLET PANELS PG P.K January

20 Vehicle Power (RV) Power Outlet Panels Park Light Product Description The elegant design of the Park Light complements park landscaping and provides essential lighting required for park safety and security for campground paths, walkways, recreational areas, and even pools. The Park Light has a 360 degree lighting design and a resin housing that will never rust or deteriorate. At 10 /kwh, it will provide area lighting at a cost of less than 50 /month and the bulbs will last for about three years. The housing has a limited lifetime warranty, and the unit is CSA certified. The Park Light is a perfect lighting fixture for any campground. Features, Functions, and Benefits Photocell controlled 9, 14, or 23-Watt fluorescent light or LED light with amber or clear lens. Heavy resin housing with a two-part polyurethane coating for a UV resistant, long lasting finish. Limited lifetime warranty on the housing. Loop-feed lugs. Available Options Direct burial ground mounting stand. Telephone connection (RJ11). Cable TV connection. High-speed Internet connector (RJ45). Single 1/4-turn brass ball valves (brass T connection) with 3/4-inch hose bibs for water connection. Anti-siphon backflow preventer for the water supply connection. Wireless remote reading of electronic kilowatt meter. Factory installed pre-wired circuit breakers for additional electrical loads. Custom paint colours. Standards and Certifications CSA Certified File POWER OUTLET PANELS PG P.K January

21 Vehicle Power (RV) Power Outlet Panels Product Selection When quoting or selecting a Park Light Power Outlet Panel, the following items should be considered: Number and type of receptacles. Lighting wattage, lens colour, control, and electrical protection method. Number of water connections. Number of phone, cable, or internet connections. Electrical bus connection style. Additional factory installed hardwired breakers for other planned loads. Table 10. Park Light Power Outlet Panel Catalogue Number System R D Y B U C Light Style & Lens Colour A = 9W, Amber C = 14W, Amber D = 23W, Amber F = None, Amber G = 9W, Clear I = 14W, Clear J = 23W, Clear L = None, Clear S = LED Amber U = LED Clear Photocell Light Control Y = Yes N = No Lighting Protection B = Circuit Breaker F = Fuse Metering Type U = Unmetered D = Digital Electronic Meters R = Receptacles Metered Individually Not all option combinations are possible. Contact your Eaton sales rep for confirmation of correct catalogue number selection. For receptacle configurations, see table 11. Receptacle 1 Side 2 0 = No Receptacle 1 = 20A GFCI Duplex 2 = 30A 125V 3 = 50A 125V 4 = 50A 125/250V Receptacle 2 Side 1 0 = No Receptacle 1 = 20A GFCI Duplex 2 = 30A 125V 3 = 50A 125V 4 = 50A 125/250V Receptacle 1 Side 1 0 = No Receptacle 1 = 20A GFCI Duplex 2 = 30A 125V 3 = 50A 125V 4 = 50A 125/250V Water Connections 0 = None 1 = Single 1/2 Hose Bib 2 = Two 1/2 Hose Bibs 3 = Single 3/4 Hose Bib 4 = Two 3/4 Hose Bibs Phone, Cable TV, & Internet Connection Options Phone Cable TV Internet A B C D E F G H I J M P S T U V W X Y Z Hardwired Circuit Breakers 0 = None 2 = 20A Double Pole 3 = 30A Single Pole Bus Options C = Single Phase Mechanical Lugs S = Single Phase 1/4 Compression Studs F = Three Phase 1/4 Compression Studs 19 POWER OUTLET PANELS PG P.K January

22 Vehicle Power (RV) Power Outlet Panels Table 11. Standard and Locking Receptacle Configurations Catalogue Number Code Blade Arrangement NEMA Designation Description Feeder Circuit Breaker R2GFI 20 Amperes, 125 Volts, 2-Pole, 3-Wire (w/gfi) 1-Pole 20 Amperes 2 TT-30R 30 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 30 Amperes R 50 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 50 Amperes R 50 Amperes, 125/250 Volts, 3-Pole, 4-Wire, Grounding 2-Pole 50 Amperes Table 12. Park Light Power Outlet Panel Catalogue Number Selection Examples Mounting Metering Catalogue Receptacle Description Light & Lens Water Phone Number Side 1 Side 1 Side 2 Connections Cable Receptacle 1 Receptacle 2 Receptacle 1 Internet Pedestal Unmetered RAYBU430100C 50A, 125/250V 50A, 125V 9W, Amber 1 Pedestal Unmetered RCYBU20110BC 30A, 125V 20A 125V GFCI 14W, Amber 1 P, I Pedestal Metered RGYBD300100C 50A, 125V 9W, Clear 1 Pedestal Metered RAYBD22000EC 30A, 125V 30A, 125V 9W, Amber 0 P, C, I Breakers used are QCR type. POWER OUTLET PANELS PG P.K January

23 Vehicle Power (RV) Power Outlet Panels Dimensions Figure 13. Park Light Power Outlet Panel Dimensions (In [mm]) BUS BAR ACCESS TOP REMOVED INSIDE TOP [340.2] [786.9] 7.90 [200.7] 7.90 [200.7] SIDE VIEW FRONT VIEW 21 POWER OUTLET PANELS PG P.K January

24 Mounting Figure 14. Park Light Power Outlet Panel Mounting Dimensions (In [mm]) 7.50 [190.5] 5.50 [139.7] Ø.41 [Ø10.3] 2.11 [53.7] 2.11 [53.7] 7.50 [190.5] 5.50 [139.7] 2.50 [63.5] 2.50 [63.5] 2.50 [63.5] WATER ACCESS 2.11 [53.7] 2.11 [53.7] 2.50 [63.5] ELECTRICAL ACCESS POWER OUTLET PANELS PG P.K January

25 Vehicle Power (RV) Power Outlet Panels Powerhouse Product Description The Powerhouse RV utility centre is our most popular pedestal for single or double RV sites because of its full complement of standard features and available option packages able to meet any user requirement. The housing is made of durable weatherproof resin and will never rust or deteriorate. That s why it comes with a limited lifetime warranty. Because the Powerhouse can accommodate two RV sites, it s an economical pedestal for double site installation. This unit is ideal for new, or when retrofitting, full service RV parks. Features, Functions, and Benefits Photocell controlled 9, 14, or 23-Watt fluorescent light or LED light with amber or clear lens. Lockable weatherproof doors that protect receptacles and breakers. Hose and cable brackets. Heavy resin housing with a two-part polyurethane coating for a UV resistant, long lasting finish. Limited lifetime warranty on the housing. Loop-feed lugs. Hinged pedestal base providing easy access for installation and maintenance. Backlit faceplate for night-time visibility. Available Options Direct burial ground mounting stand. Telephone connection (RJ11). Cable TV connection. High-speed Internet connector (RJ45). Single or dual 1/4-turn brass ball valves (brass T connection) with 3/4-inch hose bibs for water connection. Anti-siphon backflow preventer for the water supply connection. Wireless remote reading of electronic kilowatt meter. Single-feed mechanical bus bars for up to 350 kcmil wire. Factory installed pre-wired circuit breakers for additional electrical loads. Meter socket for each side powered (to accept glass style meter). Water meter with remote reading capability. Custom paint colours. Standards and Certifications CSA Certified File POWER OUTLET PANELS PG P.K January

26 Vehicle Power (RV) Power Outlet Panels Product Selection When quoting or selecting a Powerhouse Power Outlet Panel, the following items should be considered: Number and type of receptacles. Lighting wattage, lens colour, control, and electrical protection method. Number of water connections. Number of phone, cable, or internet connections. Electrical bus connection style. Additional factory installed hardwired breakers for other planned loads. Table 13. Powerhouse Power Outlet Panel Catalogue Number System P D U C Light Style & Lens Colour A = 9W, Amber C = 14W, Amber D = 23W, Amber F = None, Amber G = 9W, Clear I = 14W, Clear J = 23W, Clear L = None, Clear S = LED, Amber U = LED, Clear Metering Type U = Unmetered D = Digital Electronic Meters (Side 1) T = Digital Electronic Meters (Side 2) B = Digital Electronic Meters (Both Sides) R = Receptacles Metered Individually M = One Meter Socket (100A) N = Two Meter Sockets (100A each) R1S1 R2S1 R3S1 R4S1 R1S2 R2S2 R3S2 R4S2 Receptacle Options 0 = No Receptacle 1 = 20A GFCI Duplex 2 = 30A 125V 3 = 50A 125V 4 = 50A 125/250V 5 = 100A 120/208V 6 = 100A 125/250V 7 = 100A 277/480V 8 = 100A 480V Not all option combinations are possible. Contact your Eaton sales rep for confirmation of correct catalogue number selection. For receptacle configurations, see table 14. Water Connections 0 = None 1 = Single 3/4 Hose Bib 2 = Dual 3/4 Hose Bib 3 = Single Water (Male) 4 = Dual Water (Male) 5 = Single Male, 2 Valves 6 = 1 Frost Free 7 = 2 Frost Free Extra GFCI Receptacle (Unmetered) 0 = None 1 = 1 Extra GFCI 2 = 2 Extra GFCIs Bus Options C = Single Phase Mechanical Lugs T = Three Phase Mechanical Lugs S = Single Phase 3/8 Compression Studs F = Three Phase 3/8 Compression Studs Phone, Cable TV, & Internet Connection Options Phone Cable TV Internet A B C D E F G H I J M P S T U V W X Y Z POWER OUTLET PANELS PG P.K January

27 Vehicle Power (RV) Power Outlet Panels Table 14. Standard and Locking Receptacle Configurations Catalogue Number Code Blade Arrangement NEMA Designation Description Feeder Circuit Breaker R2GFI 20 Amperes, 125 Volts, 2-Pole, 3-Wire (w/gfi) 1-Pole 20 Amperes 2 TT-30R 30 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 30 Amperes R 50 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 50 Amperes R 50 Amperes, 125/250 Volts, 3-Pole, 4-Wire, Grounding 2-Pole 50 Amperes Amperes, 120/208 Volts, 4-Pole, 5-Wire, Grounding 3-Pole 100 Amperes Amperes, 125/250 Volts, 3-Pole, 4-Wire, Grounding 2-Pole 100 Amperes Amperes, 277/480 Volts, 4-Pole, 5-Wire, Grounding 3 Pole 100 Amperes Amperes, 480 Volts, 3-Pole, 4-Wire, Grounding 3-Pole 100 Amperes Table 15. Powerhouse Power Outlet Panel Catalogue Number Selection Examples Metering Catalogue Receptacle Description Extra GFI Light & Lens Water Phone Number R1 R2 R3 R3 Receptacle Connections Cable, Internet Unmetered PDU C Side 1 50A, 125/250V 30A, 125V 1 23W, Amber 0 Side 2 20A 125V GFCI Unmetered PJU DC Side 1 30A, 125V 30A, 125V 2 23W, Clear 2 P, C Side 2 50A, 125V Metered PDM C Side 1 50A, 125V 1 9W, Amber 2 Side 2 50A, 125V Metered PSM EC Side 1 50A, 125/250V 0 LED, Amber 0 P, C, I Side 2 50A, 125V Breakers used are QCR type. Breakers used are G Frame Moulded Case Circuit Breakers. 25 POWER OUTLET PANELS PG P.K January

28 Vehicle Power (RV) Power Outlet Panels Dimensions Figure 15. Powerhouse Power Outlet Panel Dimensions (In [mm]) Top (1117.6) Side View Front View (349.2) Broken View POWER OUTLET PANELS PG P.K January

29 Mounting Figure 16. Powerhouse Power Outlet Panel Mounting Dimensions Ø0.47 ELECTRICAL AND COMMUNICATIONS 1 DIA. HOLE FOR PH/CATV DIA. HOLE FOR WATER WATER CONNECTION Ø2.88 WARNING Use of any other type of bus bar assembly other than the one provided by or approved by the manufacturer will void the warranty any may also void the listing and could result in property loss or personal injury Ø2.88 Ø DIA. HOLE FOR PH/CATV 0.78 ELECTRICAL AND COMMUNICATIONS 27 POWER OUTLET PANELS PG P.K January

30 Vehicle Power (RV) Power Outlet Panels Powerhouse Stainless Steel Product Description For long lasting durability and low maintenance, the stainless steel Powerhouse-SS pedestal is the most resilient power centre offered. We have worked more than three years to design a stainless steel pedestal that would meet and exceed the applicable codes and withstand harsh inland and coastal environments. Features, Functions, and Benefits Photocell controlled 9, 14, or 23-Watt fluorescent light or LED light with amber or clear lens. Lockable weatherproof doors that protect receptacles and breakers. Hose and cable brackets. Stainless steel housing with a limited lifetime warranty. Limited lifetime warranty on the housing. Loop-feed 3/8-inch copper compression stud bus bars that can accept 350kcmil cable. Large removable access panel for easy installation and maintenance. Backlit faceplate for night time visibility. Available Options Telephone connection (RJ11). Cable TV connection. High-speed Internet connector (RJ45). Single or dual 1/4-turn brass ball valves (brass T connection) with 3/4-inch hose bibs for water connection. Anti-siphon backflow preventer for the water supply connection. Wireless remote reading of electronic kilowatt meter. Loop-feed lugs. Single-feed mechanical bus bars for up to 350 kcmil wire. Factory installed pre-wired circuit breakers for additional electrical loads. Meter socket for each side powered (to accept glass style meter). Water meter with remote reading capability. Custom paint colours. Standards and Certifications CSA Certified File POWER OUTLET PANELS PG P.K January

31 Vehicle Power (RV) Power Outlet Panels Product Selection When quoting or selecting a Powerhouse Stainless Steel Power Outlet Panel, the following items should be considered: Number and type of receptacles. Lighting wattage, lens colour, control, and electrical protection method. Number of water connections. Number of phone, cable, or internet connections. Electrical bus connection style. Additional factory installed hardwired breakers for other planned loads. Table 16. Powerhouse Stainless Steel Power Outlet Panel Catalogue Number System Z D U C Light Style & Lens Colour A = 9W, Amber C = 14W, Amber D = 23W, Amber F = None, Amber G = 9W, Clear I = 14W, Clear J = 23W, Clear L = None, Clear S = LED, Amber U = LED, Clear Metering Type U = Unmetered D = Digital Electronic Meters (Side 1) T = Digital Electronic Meters (Side 2) B = Digital Electronic Meters (Both Sides) R = Receptacles Metered Individually M = One Meter Socket (100A) N = Two Meter Sockets (100A each) R1S1 R2S1 R3S1 R4S1 R1S2 R2S2 R3S2 R4S2 Receptacle Options 0 = No Receptacle 1 = 20A GFCI Duplex 2 = 30A 125V 3 = 50A 125V 4 = 50A 125/250V 5 = 100A 120/208V 6 = 100A 125/250V 7 = 100A 277/480V 8 = 100A 480V Not all option combinations are possible. Contact your Eaton sales rep for confirmation of correct catalogue number selection. For receptacle configurations, see table 17. Water Connections 0 = None 1 = Single 3/4 Hose Bib 2 = Dual 3/4 Hose Bib 3 = Single Water (Male) 4 = Dual Water (Male) 5 = Single Male, 2 Valves 6 = 1 Frost Free 7 = 2 Frost Free Extra GFCI Receptacle (Unmetered) 0 = None 1 = 1 Extra GFCI 2 = 2 Extra GFCIs Bus Options C = Single Phase Mechanical Lugs T = Three Phase Mechanical Lugs S = Single Phase 3/8 Compression Studs F = Three Phase 3/8 Compression Studs Phone, Cable TV, & Internet Connection Options Phone Cable TV Internet A B C D E F G H I J M P S T U V W X Y Z POWER OUTLET PANELS PG P.K January

32 Vehicle Power (RV) Power Outlet Panels Table 17. Standard and Locking Receptacle Configurations Catalogue Number Code Blade Arrangement NEMA Designation Description Feeder Circuit Breaker R2GFI 20 Amperes, 125 Volts, 2-Pole, 3-Wire (w/gfi) 1-Pole 20 Amperes 2 TT-30R 30 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 30 Amperes R 50 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 50 Amperes R 50 Amperes, 125/250 Volts, 3-Pole, 4-Wire, Grounding 2-Pole 50 Amperes Amperes, 120/208 Volts, 4-Pole, 5-Wire, Grounding 3-Pole 100 Amperes Amperes, 125/250 Volts, 3-Pole, 4-Wire, Grounding 2-Pole 100 Amperes Amperes, 277/480 Volts, 4-Pole, 5-Wire, Grounding 3 Pole 100 Amperes Amperes, 480 Volts, 3-Pole, 4-Wire, Grounding 3-Pole 100 Amperes Table 18. Powerhouse Stainless Steel Power Outlet Panel Catalogue Number Selection Examples Metering Catalogue Receptacle Description Extra GFI Light & Lens Water Phone Number R1 R2 R3 R3 Receptacle Connections Cable, Internet Unmetered ZDU C Side 1 50A, 125/250V 30A, 125V 1 23W, Amber 0 Side 2 20A 125V GFCI Unmetered ZJU DC Side 1 30A, 125V 30A, 125V 2 23W, Clear 2 P, C Side 2 50A, 125V Metered ZDM C Side 1 50A, 125V 1 9W, Amber 2 Side 2 50A, 125V Metered ZSM EC Side 1 50A, 125/250V 0 LED, Amber 0 P, C, I Side 2 50A, 125V Breakers used are QCR type. Breakers used are G Frame Moulded Case Circuit Breakers. POWER OUTLET PANELS PG P.K January

33 Vehicle Power (RV) Power Outlet Panels Dimensions Figure 17. Powerhouse Stainless Steel Power Outlet Panel Dimensions (In [mm]) (1016.0) 9.88 (251.0) 31 POWER OUTLET PANELS PG P.K January

34 Air Conditioning Disconnects Mounting Figure 18. Powerhouse Stainless Steel Power Outlet Panel Mounting Dimensions 1/2 9-9/16 MOUNTING HOLE (TYP.) 7-5/16 3/8 STUD (TYP.) SIDE 2 ELECTRICAL ACCESS 9-7/8 5-3/4 8-1/4 WATER PHONE/ CATV 8-1/16 Ø 3/8 x 1 STAINLESS STEEL STUD SIDE 1 12 AWG STAINLESS STEEL POWER OUTLET PANELS PG P.K January

35 Vehicle Power (RV) Power Outlet Panels Firehouse Product Description The Firehouse is designed to provide added fire safety to RV parks and campgrounds. The Firehouse provides a convenient location and easy access to fire extinguishers and to an optional life ring when installed around pools and waterfront amenities. In addition, the Firehouse provides area lighting for easy identification during an emergency and for security lighting around the unit. The Firehouse can be equipped with an alarm strobe light and siren which are automatically activated when the fire extinguisher cabinet door is opened or the optional life ring is removed. Features, Functions, and Benefits Photocell controlled 9, 14, or 23-Watt fluorescent light or LED light with amber or clear lens. Stainless steel housing with oven baked enamel finish with a resin base and top. Limited lifetime warranty on the housing. Available Options Alarm strobe and siren. 24 Life ring for poolside or dockside installations. 10 or 20lb Fire extinguisher. 33 POWER OUTLET PANELS PG P.K January

36 Vehicle Power (RV) Power Outlet Panels Product Selection When quoting or selecting a Firehose pedestal, the following items should be considered: Lighting wattage, lens colour, photocell control. Siren and strobe light. Fire extinguisher. Life ring. Table 19. Firehouse Pedestal Catalogue Number System F D Y A E R Light Style & Lens Colour A = 9W, Amber C = 14W, Amber D = 23W, Amber F = None, Amber G = 9W, Clear I = 14W, Clear J = 23W, Clear L = None, Clear S = LED, Amber U = LED, Clear Life Ring N = No Life Ring R = Include Life Ring Fire Extinguisher N = No Fire Extinguisher E = Include 10lb Extinguisher X = Include 20lb Extinguisher Alarm and Strobe N = No Alarm and Strobe A = Include Alarm and Strobe Photocell Light Control Y = Yes N = No Table 20. Firehouse Pedestal Catalogue Number Selection Examples Catalogue Number Light & Lens Photocell Controlled Alarm and Strobe Fire Extinguisher Life Ring FAYAER 9W, Amber Yes Yes 10lb Yes FSYAXN LED Amber Yes Yes 20lb No FGYNNN 9W, Clear Yes No No No FDNANR 23W, Amber No Yes No Yes Not all option combinations are possible. Contact your Eaton sales rep for confirmation of correct catalogue number selection. POWER OUTLET PANELS PG P.K January

37 Vehicle Power (RV) Power Outlet Panels Dimensions Figure 19. Firehouse Pedestal Dimensions (In [mm]) (1034.9) 9.88 (250.8) (293.0) 35 POWER OUTLET PANELS PG P.K January

38 Vehicle Power (RV) Power Outlet Panels Mounting Figure 20. Firehouse Pedestal Mounting Dimensions 10-1/2 Electrical Access Hole for 3/8 Bolt or Stud POWER OUTLET PANELS PG P.K January

39 Product Description The Marina Power Outlet Panel is designed for outdoor service to meet temporary power requirements for boats that are docked at a marina slip. Marina owners need to provide a safe and reliable means for boating customers to access electricity, water, telephone, internet, and cable television. provide this convenient and safe access means to these utility services. In addition they can provide photocell controlled premise lighting in a visually attractive packaging style that fits in well with the surrounding dock environment. Features, Functions, and Benefits Designed for outdoor service to meet power outlet requirements. Marine grade receptacles conform to NEMA, ANSI or IEC configurations. Factory installed type QC circuit breakers. Panels come from the factory completely assembled, prewired, and tested, ready for easy installation. Lighted pedestal options include amber or clear lenses with compact fluorescent or LED lamps. Lockable receptacle access doors swing up for user convenience and ease of access to breakers and receptacles. Pedestal style power outlet panels have open bottoms for entry of feeder cabling. Pedestal enclosures are built of a heavy resin with a twopart UV resistant polyurethane coating. Stainless steel models are built from 18 gauge stainless steel and are powder coated to provide a long lasting, maintenance free finish. Some available factory installed options include hose bibs for water connections; telephone, cable, and internet connections; meter sockets; wireless electronic power metering; and water metering. Custom paint colours are also available in many pedestal styles. Contact your local Eaton sales office or rep for colour availability and pricing. The Firehouse pedestal provides a convenient and eye-catching storage location for an emergency fire extinguisher and life ring. Optional audible and visual alarms signal opening of the extinguisher door or removal of the life ring. Standards and Certifications CSA Certified (Select Models) Receptacles conform to NEMA, ANSI, or IEC configurations. 37 POWER OUTLET PANELS PG P.K January

40 Newport Harbor Mate Product Description The Newport Harbor Mate provides many of the features and options of our other full size pedestals, but in a compact self-contained unit. The Newport Harbor Mate is ideally suited for single slip service and private docks. It can be mounted to our stainless steel stand, a post, or any wall. It comes standard with a resin housing that will never rust or deteriorate and photocell controlled lighting that can aid in night-time hook-ups. The Newport Harbor Mate is CSA approved and comes with a limited lifetime warranty on the housing. Features, Functions, and Benefits Photocell controlled 9 or 14- Watt fluorescent light or LED light with amber or clear lens. Lockable weatherproof door that protects receptacles and breakers. Heavy resin housing. Limited lifetime warranty on the housing. Designed to mount on a post, wall, or an optional stand. Loop-feed compression stud or mechanical lugs. Available Options 36-inch stainless steel stand. 60-inch direct burial aluminum stand. Telephone connection (RJ11). Cable TV connection. High-speed Internet connector (RJ45). Single or dual 1/4-turn brass ball valves (brass T connection) with 3/4-inch hose bibs for water connection. Anti-siphon backflow preventer for the water supply connection. Single-feed mechanical bus bars for up to 350 kcmil wire available with optional stand. Wireless remote reading of electronic kilowatt meter. Factory installed pre-wired circuit breakers for additional electrical loads. Standards and Certifications CSA Certified File POWER OUTLET PANELS PG P.K January

Temporary Power Outlet Panels

Temporary Power Outlet Panels Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order

More information

Temporary Power Outlet Panels. Selection and Application Guide. www.talonmetering.com

Temporary Power Outlet Panels. Selection and Application Guide. www.talonmetering.com Temporary Power Outlet Panels Selection and Application Guide www.talonmetering.com 2012 Siemens Industry, Inc. www.talonmetering.com Talon meter mounting equipment For more than half a century, Talon

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

Mini Power-Zone Unit Substation

Mini Power-Zone Unit Substation Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

Utility Distribution Systems

Utility Distribution Systems Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

For Models #6-5001, #6-7501, #10-7501 & #10-12K1

For Models #6-5001, #6-7501, #10-7501 & #10-12K1 EmerGen Switch Manual Transfer Switch Manufactured by CONNECTICUT ELECTRIC SWITCH MFG. CO. 1-800-730-2557 OWNER S MANUAL & INSTALLATION INSTRUCTIONS For Models #6-5001, #6-7501, #10-7501 & #10-12K1 PLEASE

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 October 00 Utilities Servicing Texas Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility CenterPoint Energy (Reliant & HL&P).............................

More information

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC ELECTRICAL SERVICE REQUIREMENTS ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC TABLE OF CONTENTS TITLE SECTION NO. List of Approved Electric Utility Service Equipment Requirements Committee

More information

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT The purpose of these specifications is to insure that there are minimum

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp SERVICE ENTRANCE - UNDERGROUND 07-01-15 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS

More information

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document

More information

Electrical Code Regulation

Electrical Code Regulation Electrical Code Regulation St. Clair County has adopted the 2005 National Electrical Code in its entirety for the unincorporated areas of the county and all communities that have contracted with the county

More information

Magnum Mobile Generator MMG55 Specifications

Magnum Mobile Generator MMG55 Specifications Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems.

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems. SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes wall switches; wall dimmers; receptacles; multioutlet assembly; and device plates and decorative box covers. B. Related

More information

Electrical Grounding. Appendix C

Electrical Grounding. Appendix C Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment

More information

RAY-MAX Integrated Solar Power Strip

RAY-MAX Integrated Solar Power Strip RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...

More information

Customer Metering and Services Guide

Customer Metering and Services Guide This document is an uncontrolled copy and may not be the most current copy. The most current copy is available at www.atcoelectric.com. This document is the property of ATCO Electric and may be updated

More information

Section 10 Electric Switchboards: 0 Through 600 Volts

Section 10 Electric Switchboards: 0 Through 600 Volts Section 10 Electric Switchboards: 0 Through 600 Volts 10.1. Scope This section provides specific dimensions and details for service and meter equipment that is assembled by the manufacturer in freestanding,

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these

More information

Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index

Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index Section R Index Product Page Number and R-2 3 Weatherproof Cable and Static Discharge Reels R-4 R-5 R-6 Index www.hubbell-wiring.com and and Hubbell Electric Cord and Cable Reels Hubbell Wiring Device

More information

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264 BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used

More information

Type 1, 3, & 3R Enclosures

Type 1, 3, & 3R Enclosures Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................

More information

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: Signed completed Electrical Permit application form. Minnesota law requires all electrical work is to be performed by licensed,

More information

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS This guideline has been prepared to assist the owner/occupant of a single family dwelling with compliance to the requirements of the National Electrical

More information

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 PL Series Load Centers Features and Product Offering -4-5 PL Series

More information

ELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01)

ELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01) ELECTRICAL INSPECTION BULLETIN (Effective 2000-03-01) Rule 28-900 Standby Generator Installations Due to the increasing number of standby generator installations being established to maintain continuity

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

Electrical Service Guidelines

Electrical Service Guidelines Electrical Service Guidelines Middle Tennessee Electric Membership Corporation Revised: May 23, 2013 MTEMC's Electrical Guidelines TABLE OF CONTENTS Right-of-Way Clearance Guide 3 MTEMC Requirements 4

More information

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures Meter Boxes SMB s To house a single phase kilowatt hour meter Standard kwh meter mounting Square or triangular securing screw Stand off for circuit breaker Optional circuit breaker reset rod DMB s To house

More information

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER 300W 600W 900W 1200W ATTENTION: Please read and understand thoroughly this installation guide to ensure safe and efficient operation of this Power Module 1 Open

More information

Roped Hydraulic Residential Elevator Specifications

Roped Hydraulic Residential Elevator Specifications January 1, 2004 Roped Hydraulic Residential Elevator Specifications P.O. Box 749, 5191 Stump Rd., Plumsteadville, PA 18949 Toll Free: 888-443-2800, Phone: 215-766-3380, Fax: 215-766-3385 CONTENTS Part

More information

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS 01. SAFETY INSPECTION of service equipment at FPL Power Source 02. Construction GFI power outlets (Temp Pole for Construction) 03. 90 day temporary power

More information

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE SHORE POWER Safely Connecting Ships to Shore SHIP-TO-SHORE SOLUTIONS FOR MILITARY & COMMERCIAL APPLICATIONS SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE ESL Power Systems, Inc. ESL has established

More information

Approved Meter Sockets and Cabinets

Approved Meter Sockets and Cabinets Single Unit Residential Guide 1 PHASE, 120/240 VOLT S METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to center of meter ± 100 mm ( 4

More information

Parallel Redundant Uninterruptible Power Supply

Parallel Redundant Uninterruptible Power Supply 9 315 Parallel Redundant Uninterruptible Power Supply Installation/Operation Manual 164202013 Rev. D ------------------------------------------------------------------------ ------------------------------------------------------------------------

More information

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel CHAPTER 4 UTILITY SYSTEMS ELECTRICAL Utility Systems Electrical The electrical supply to your home begins outside, where you will see either an overhead feed and piping down the side of your home or (if

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability HVL 5 38 kv Load Interrupter Switchgear The Standard for Performance, Protection and Dependability For a generation of engineers, Square D High Voltage Load (HVL ) Interrupter Switchgear by Schneider Electric

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

Line Loss WSDOT Winter 2008 BZA

Line Loss WSDOT Winter 2008 BZA Electrical Design Training Class Line Loss WSDOT Winter 2008 BZA Presented by: Keith Calais 1 OHM S LAW P = Watts (Power) I = CURRENT (AMPERES) R = RESISTANCE (OHMS) E = ELECTROMOTIVE FORCE (VOLTS) P =

More information

The Different Types of AC Power Connectors in North America

The Different Types of AC Power Connectors in North America The Different Types of AC Power Connectors in North America White Paper #20 Executive Summary A confusing array of AC power plugs and receptacles exist to deliver power to various electronic loads. This

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

IEC 309 INTERLOCKS NORTH AMERICAN

IEC 309 INTERLOCKS NORTH AMERICAN IEC 309 INTERLOCKS NORTH AMERICAN SWITCH VERSION with MCB (Circuit Breakers) 20, 30, 60 Amp NEMA 4X Watertight (IP67) Drawing A (See Drawing on Specification Page) 20, 30, 60 Amp Spashproof (IP44) Drawing

More information

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the

More information

Low Voltage Transformers Sealed, General Purpose, Dry Type

Low Voltage Transformers Sealed, General Purpose, Dry Type Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................

More information

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

MOBILE HOME SERVICE REQUIREMENTS GAS

MOBILE HOME SERVICE REQUIREMENTS GAS ELECTRIC AND GAS 1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 GENERAL 4.0 REFERENCE MATERIAL 5.0 TYPICAL UNDERGROUND UTILITY LAYOUT 6.0 METER PAD DETAILS 7.0 GENERAL INSTALLATION PROCEDURES 8.0 PEDESTAL SPECIFICATIONS

More information

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1 Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader

More information

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850 Montgomery County Regulation on: ADOPTION OF THE 2008 NATIONAL ELECTRICAL CODE DEPARTMENT OF PERMITTING SERVICES Issued by County Executive Regulation # 15-09 Authority: Code Section 17-2 and 17-3 Supersedes:

More information

Transfer Switch 30 Amps STS-30. Manual. Please read this manual before operating your transfer switch

Transfer Switch 30 Amps STS-30. Manual. Please read this manual before operating your transfer switch Transfer Switch 30 Amps STS-30 Owner's Manual Please read this manual before operating your transfer switch Section 1 Introduction Function of a Transfer Switch In case of failure of the main AC power

More information

Top Commercial / Residential Electrical Requirements *

Top Commercial / Residential Electrical Requirements * Department of Community Development Building Division 4800 West 92 nd Avenue Westminster, Colorado 80031 For Information call (303) 658-2075 Fax (303) 706-3922 www.westminsterpermits.com Top Commercial

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM 7/00 INSTALLATION INSTRUCTION SPEC. SHEET 99052 99063 City of New York Calendar #40747 Copyright c 2000 ALFA Lighting, Inc. All rights reserved. Call:1-415-975-8080 QUICK JACK QJS R LISTED 9901483 ETL

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs Part #: GAU-LB-400 Page: 1 Made in USA Compliant The GAU-LB-400 LED Low Bay Light offers high light output from a compact

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) August, 2009 Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) Type VBPA (Aluminum) / Type VBPC (Copper) Type VBSA (Aluminum) / Type VBSC (Copper) PASCOR Air Break Switch Technology PASCOR offers

More information

Industrial Ringdown/Autodialer Telephone SCR Series

Industrial Ringdown/Autodialer Telephone SCR Series Industrial Communications Worldwide Industrial Ringdown/Autodialer Telephone Installation & Operation SCR 11 SCR 41 P005603 Rev. A 060612 5/28/2007 3:58 PM 7552-10th Street N.E. Calgary, Alberta, Canada

More information

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11 Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU

More information

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE Toll Free Telephone Numbers Residential Services 800.454.3853 Commercial Services 800.653.5307 Utility Locating Company N.C. 800.632.4949 S.C. 888.721.7877

More information

Advantages of a Company Switch vs. a Safety Switch Receptacle Combination:

Advantages of a Company Switch vs. a Safety Switch Receptacle Combination: Advantages of a Company Switch vs. a Safety Switch Receptacle Combination: Why a Company Switch Delivers Greater Benefits A Lex Products Corporation Whitepaper. Copyright 2012. Overview: Advantages of

More information

TERMINATION ENCLOSURE OPTIONS

TERMINATION ENCLOSURE OPTIONS TERMINATION ENCLOSURE OPTIONS Add suffix: R - Reverse Stagger the Bus Bars (to run cable in from the top) CU - Copper NEMA Mount Bus Bars C - Plastisol Covers for Bus Bars DF - Dead Fronts T - Tin Plated

More information

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE Applies to Models: 75W, 150W, 300W, 600W, 900W, 1200W ATTENTION: Please read this guide carefully to ensure safe and efficient

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

HL Series - Commercial Heaters Tankless Water Heating Solutions

HL Series - Commercial Heaters Tankless Water Heating Solutions HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

How To Power A Power Supply On A Powerline From A Power Source To A Power Box

How To Power A Power Supply On A Powerline From A Power Source To A Power Box Power Base AI Power Base AI Application Guide Table of Contents Product Overview Our Philosophy On Electrical... 4 System Overview... 5 Power Base AI Statement of Line.... 6 Power Base AI Components...

More information

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns for harsh & hazardous (classfied) locations Construction Demolition Maintenance Turnarounds Shutdowns D-13 temporary / mobile power Temporary power products are used on industrial and construction sites

More information

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property. INTRODUCTION These rules are issued for use by Customers, builders, electrical contractors, architects, engineers, etc. The rules require the installation of safe and adequate wiring and electrical equipment,

More information

The Different Types of AC Power Connectors in North America

The Different Types of AC Power Connectors in North America The Different Types of AC Power Connectors in North America White Paper 20 Revision 1 by James Spitaels > Executive summary A confusing array of AC power plugs and receptacles exist to deliver power to

More information

AMERBRITE UNDERWATER WHITE LED POOL LAMP

AMERBRITE UNDERWATER WHITE LED POOL LAMP AMERBRITE UNDERWATER WHITE LED POOL LAMP FOR USE ONLY WITH PENTAIR AMERLITE LUMINAIRE INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information

Chapter 9. Bonding and Grounding

Chapter 9. Bonding and Grounding Chapter 9 Bonding and Grounding Objectives Describe why the cable should be bonded Describe bonding and grounding procedures Define Bonding and Grounding Explain Safety Benefits and intent of bonding and

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range. ENGLISH ESPAÑOL INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range. LRE3025ST LRE3085ST LRE3083ST LRE3083SB LRE3083SW LRE3021ST LDE3037ST

More information

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12 Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Cleaveland/Price Type TP-C2 Motor Operator

More information

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations. PLEASE NOTE This document, prepared by the Legislative Counsel Office, is an office consolidation of this regulation, current to August 1, 2013. It is intended for information and reference purposes only.

More information

TSn SERIES Surge Protective Device

TSn SERIES Surge Protective Device Page: 1 of 8 TSn SERIES Surge Protective Installation & Operation Manual 3621 Saunders Avenue www.systems.us Ph 804.355.1100 Richmond, VA 23227 4354 Sales@Systems.us Fax 804.355.8900 Page: 2 of 8 Quick

More information

REFRIGERATION. Standard Features & Accessories. Model Options. Built-In 30 W. Full-Height Wine Cellar. All models include. VCWB300 Professional

REFRIGERATION. Standard Features & Accessories. Model Options. Built-In 30 W. Full-Height Wine Cellar. All models include. VCWB300 Professional Standard Features & Accessories All models include Capacity accommodates up to 150 full-size bottles o 84 H./24 D. Exclusive TriTemp storage system o Three independent temperature zones o Settings are

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

TRAILER WIRING AND COMMUNICATION SYSTEMS Systèmes de Communication et Filage de Remorques Sistemas de Comunicación y Cableado para Caravanas

TRAILER WIRING AND COMMUNICATION SYSTEMS Systèmes de Communication et Filage de Remorques Sistemas de Comunicación y Cableado para Caravanas 162 Ultra-Pin Receptacle, Two Hole Mount Redundant ground through frame No rust, die-cast zinc Heavy bosses for extra rigidity Barrel slanted to drain moisture Mounting holes slotted for universal fit

More information

Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers

Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers 9229 Waterford Centre Dr. Bldg C, Suite 110 Austin, Tx 78758 Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers Current Version: 13 AC Modules are a new product

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Plugs and Receptacles

Plugs and Receptacles Plugs and Receptacles Industrial Heavy Duty Interlocked Application and Selection Applications: Where extra protection is a requirement; interlocked units provide dead front receptacles; connection cannot

More information

Product Specification instalert Rapid Messenger Variable Message Sign

Product Specification instalert Rapid Messenger Variable Message Sign instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits

More information

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin

More information