1 User manual magnetic absolute positioning drive AG03/1
2 1 GENERAL REMARKS DOCUMENTATION BLOCK DIAGRAM FUNCTIONAL DESCRIPTION SYSTEM STATUS WORD OPERATING MODES Positioning mode Loop positioning Inching operation Velocity mode TORQUE DEACTIVATION RESTORE FACTORY SETTINGS VIA DIP SWITCHES SUPPLY VOLTAGE OF CONTROL ND OUTPUT STAGE DRIVE BEHAVIOR IN CASE OF POWER FAILURE CALIBRATION EXTERNAL GEAR UNIT WARNINGS / FAULTS WARNINGS FAULTS Error codes PARAMETER DESCRIPTION COMMUNICATION VIA PROFIBUS DP GENERAL REMARKS INTERFACE DATA EXCHANGE TELEGRAM SETUP (DATA EXCHANGE) Parameter Process Data Object Parameter identification value (PKW) Parameter identification (PKE) Sub-index (IND) Parameter value (PWE) Process data (PZD) FUNCTIONAL DESCRIPTION OF THE CONTROL UNITS Control word in positioning mode (master slave) Status word: Positioning mode (slave master) Flow chart: Operating mode: Positioning mode Control word: Velocity mode (master slave) Status word: Velocity mode (slave master) Flow chart: Operating mode: Velocity mode PARAMETERIZATION VIA PROFIBUS Example: read parameter Example: Write parameter DIAGNOSIS PROFIBUS ADDRESS SETUP DIAGNOSIS LEDS PROFIBUS BUS TERMINATOR DEVICE DATA BASE AND CONFIGURATION AG03/1 (PB) Date: Page 2 of 35 Art.No Mod. status 282/14
3 1 General remarks This user manual is valid with firmware version 1.00 or higher! 1.1 Documentation The following documents are associated with this document: The data sheet describes the technical data, the dimensions, the pin assignment, the accessories and the order key. The installation instructions describe the mechanical and electrical installation with all safetyrelevant conditions and the associated technical specifications. The User manual for actuator commissioning and integration into a fieldbus system. You can also download these documents at Block Diagram Profibus galvanic separation +UB control Inversepolarity protection Mains adapter Control +UB output stage Inversepolarity protection Output stage Motor Gear Encoder Battery AG03/1 (PB) Date: Page 3 of 35 Art.No Mod. status 282/14
4 2 Functional description This chapter describes the operating cycles, functions and states required for the operation of the positioning drive. Communication via Profibus DP is taken as the basis for the information presented in this chapter. 2.1 System status word The system status word of the AG03/1 consists of 2 bytes and reflects the state of the AG03/1. The System status word can be read out as a hexadecimal value via Profibus Parameter 1020 dec (see chapter 7.6: Parameterization via Profibus). High- Byte Low- Byte Bit number Fig. 1: System status word format Example (grey background): binary: hex: The table below informs about the meaning of the individual bits of the status word: Bit State Description Bit 0 0 no meaning Bit 1 0 no meaning Bit 2 0 no meaning Bit Positioning mode: In position Actual position is within the positioning window of the programmed target value. Actual position is beyond the positioning window of the programmed target value. 1 0 Velocity mode: In position Actual velocity is within the specified tolerance window of the target speed Actual speed is outside the specified tolerance window. Bit 4 Bit 5 Bit Drive travels: Drive travels Drive stands still (velocity <2 rev./min) Positioning mode: upper limit: 1 Actual position is above the higher programmed limit of limits 1+2. Travelling is possible only in negative direction in inching operation. 0 Actual position is below the programmed limit. 0 Velocity mode: no meaning 1 Positioning mode: lower limit: Actual position is below the lower programmed limit of limits 1+2. Travelling is possible only in positive direction in inching operation. Actual position is above the programmed limit. 0 0 Velocity mode: no meaning AG03/1 (PB) Date: Page 4 of 35 Art.No Mod. status 282/14
5 Bit State Description Bit 7 Driver state: 1 0 Motor is enabled Motor in control Bit 8 Fault: 1 The AG03/1 has switched to fault. The cause of the fault must be cleared and acknowledged via STW.7=1 command. For the fault cause see chapter 5.2 Bit 9 Bit 10 Bit 11 Bit 12 Bit 13 Bit 14 Bit 15 0 No fault present Positioning mode: loop travel: 1 If travel direction unequal start direction (with loop travel) 0 If travel direction equal start direction 0 Velocity mode: no meaning Supply voltage of output stage Supply voltage of output stage not applied: Gear travel is disabled! Supply voltage of output stage applied Ready-to-travel: Not ready-to-travel Ready-to-travel: AG03/1 not in fault state No active positioning Supply voltage of output stage applied actual position within limits (only positioning mode) Battery voltage: Battery voltage too low for absolute encoder. Replace the battery within half a year after reporting of the error bit! Battery voltage OK. Motor current: Motor current beyond permissible range. If this state lasts for more than 4 s, the AG03/1 switches to fault. Motor current within permissible range. Positioning mode: status 1 Positioning active in positioning mode. 0 Positioning inactive. 0 Velocity mode: no meaning 1 0 Table 1: System status word Lag error: Lag error AG03/1 cannot reach the preset speed due to too high load. This state should be avoided! Remedy: reduce programmed speed! No lag error actual speed corresponds with required speed. 2.2 Operating modes The following operating modes are available: positioning mode and velocity mode. In the positioning mode there is the additional option of travelling with inching operation Positioning mode Parameter no 20 Operating mode is programmed to positioning mode (see chapter 6: Parameter description). In the positioning mode, positioning to the target value is effected by means of a ramp function (see fig. 2), which is calculated on the basis of the actual position as well as the programmed controller parameters P (proportional factor), I (integral factor), D (differential factor), acceleration and speed (see chapter 6: Parameter description). AG03/1 (PB) Date: Page 5 of 35 Art.No Mod. status 282/14
6 After activation of the travel order (see chapter Flowchart: Positioning mode) the AG03/1 accelerates with the pre-programmed acceleration to the specified speed. The measure of deceleration to reach the target value is also defined by the parameter a-pos. As an alternative you can also choose a value for delay that deviates from acceleration (see chapter 6: Parameter No. 31 d-pos ). If the actual position is within the programmed window (see chapter 6: parameter no. 10), this will be signalled in the system status word (bit 3). The drive s behaviour upon reaching the pre-programmed window can be defined (see chapter 6: parameter no. 26). Changing controller parameters during a positioning process does not influence the current positioning operation. Speed Speed (Parameter No. 5) Delay (Parameter No. 4) Acceleration (Parameter No. 4) Delay (Parameter No. 31) Start position Target position Time Fig. 2: Ramp travel in positioning mode (direct) Travel orders can only be started if the following conditions have been met: the AG03/1 must not be switched to fault (system status word bit 8 = 0 ) actual position is within the programmed limiting values. (system status word bits = 0 ) no active travel job present (system status word bit 14 = 0) Supply voltage of the output stage is applied (system status word bit 10 = 0 ) ZSW.15 = 1 is signalled when these conditions have been met Loop positioning If the AG03/1 is operated on a spindle or an additional drive, the spindle or external drive play can be compensated by means of loop positioning. In this case, travelling to the target value is always from the same direction. This travel direction can be defined via the parameter no. 19 Pos- Art (see chapter 6: Parameter description). Example: Assumption: The direction of travelling for reaching any target position is positive (see chapter 6: Parameter no. 19 Pos Art = loop) AG03/1 (PB) Date: Page 6 of 35 Art.No Mod. status 282/14
7 Case 1 new position is greater than actual position: Direct travel to target position. Case 2 new position is smaller than actual position: The AG03/1 travels beyond the target position by the loop length (parameter no. 27) (bit 9 in the system status word signals travel direction unequal start direction); afterwards, travelling to the target value is in positive direction. Loop length (Parameter no. 27) Positioning: Loop + Positioning in positive direction Positioning in negative direction - Target value + Fig. 3: Loop+ positioning Inching operation Inching operation is enabled in the Positioning mode only. Acceleration and speed in the inching operation can be programmed via parameter no. 8 a- Inch and parameter no. 9 v- Inch. NOTICE There is no compensation for spindle play (loop positioning) in this travel type! There are three options for travelling with inching operation: Inching operation 1 Inching operation 1 is started via STW.8 = 1 in the control word. The drive travels once from the current position by the position Delta Inch. The travel direction is positive or negative depending on the arithmetical sign (parameter no. 17 Delta- Inch ). - Parameter Delta Inch < 0: negative travel direction - Parameter Delta Inch > 0: positive travel direction If the parameter no. 13 Spindle pitch is programmed to zero, then there is an incremental travelling way. If the spindle pitch is unequal zero, then the information of the Delta Inch parameter refers to the travel distance in 1/100 mm. Reaching the target position will be signalled in the system status word (bit 3). AG03/1 (PB) Date: Page 7 of 35 Art.No Mod. status 282/14
8 Inching operation 2 Inching operation 2 is started via STW.9 = 1. The drive moves as long as this bit = 1. The drive direction depends on STW.15: STW.15 = 0 positive travel direction STW.15 = 1 negative travel direction The inching speed can be influenced via two parameters and will be calculated in the drive as shown in the following example: v - Inch (parameter no 9) = 50 rpm (changeable only during standstill) Offset Inching 2 (parameter no. 30) = 47 % (changeable during inching operation) In this example, the resulting incing speed is: Inching speed = v - inch * offset inching 2 = rpm * 47 % = 24 rpm Results are always rounded up to integers. The minimum speed is 1 rpm. Manual setup mode 1 2 The manual setup mode (corresponding to inching operation 2) can be started by means of the operator keys enabling traveling of the actuator without a superordinate control. Key (1) clockwise movement Key (2) counter-clockwise movement NOTICE The manual setup mode is only available if the Profibus finite state machine of AG03/1 is not in the Data Exchange status! AG03/1 (PB) Date: Page 8 of 35 Art.No Mod. status 282/14
9 The following conditions must be met to enable the start of inching operation 1 and 2 or manual setup operation, repectively: The AG03/1 must not be switched to fault (system status word bit 8 = 0 ) No active travel job present (system status word bit 14 = 0 ) Supply voltage of the output stage is applied (system status word bit 10 = 0 ) NOTICE If the actual position is outside the programmed limits, traveling in the relevant direction is possible by means of inching operation 1 or 2 or manual setup! Velocity mode Parameter no 20 operating mode is programmed to velocity mode (see chapter 6: Parameter description). In the velocity mode, the AG03/1 accelerates to the target velocity after release of the setpoint value (see chapter Flow chart: velocity mode) and maintains this velocity until the setpoint value is disabled or a new target velocity specified. The speed is adjusted immediately to the new value when the rotational target speed is changed. The arithmetical sign of the target value determines the travel direction in the velocity mode (see chapter 6: Parameter description). Velocity Target speed (Sollwert) Disable operation Acceleration Disable setpoint or setpoint = 0 ( a - Rot parameter ) Target value released 'Stop' Time Fig. 5: Ramp velocity mode The following conditions must be met for enabling start of velocity mode via the M command of the standard protocol: The AG03/1 must not be switched to fault (system status word bit 8 = 0 ) no active travel job present (system status word bit 14 = 0 ) Supply voltage of the output stage is applied (system status word bit 10 = 0 ) If these conditions are met, this will be signalled in the system status word by bit 11 = 0. NOTICE Limits are deactivated in this operational mode! AG03/1 (PB) Date: Page 9 of 35 Art.No Mod. status 282/14
10 2.3 Torque deactivation A deactivation threshold is defined via the torque deactivation parameter (see chapter 6: Parameter description Parameter No. 29). Percent values are entered. Torque deactivation is disabled with a parameter value of 125 %. The drive will decelerate with maximum delay when the deactivation threshold is exceeded. Drive control will be maintained. NOTICE Active torque deactivation causes no error! Active torque deactivation is returned via bit 7 = 1 in parameter 1031 dec (general status register). This bit will be automatically reset when the current travel order is resumed. NOTICE This function is only available in the positioning mode! 2.4 Restore factory settings via DIP switches Procedure for restoring factory settings via the 10-pin DIP switch: 1. Switch off supply voltage. 2. Set DIP switches 1 8 depending on the parameters to be reset: Reset all parameters (see chapter 6: Parameter description) to factory settings Reset only standard parameters (see chapter 6: Parameter description) to factory settings Reset only controller parameters (see chapter 6: Parameter description) to factory settings 3. Turn on supply voltage. AG03/1 acknowledges with alternating blinking of the status LED and the bus LED. 4. Switch off supply voltage. AG03/1 (PB) Date: Page 10 of 35 Art.No Mod. status 282/14
11 5. Set the original bus address via DIP switches DIP switch number 8 must be set to the OFF position. 7. After next switching on of supply voltage, the previously selected parameters will have been reset to the factory settings. 2.5 Supply voltage of control nd output stage Both supply voltages must be applied to enable the start of traveling jobs. 2.6 Drive behavior in case of power failure NOTICE Power failure results in immediate loss torque. If the drive is moving at the time of power failure, then the drive will run out non-braked! 3 Calibration Since the measuring system is an absolute system, calibration is necessary only once at startup. During calibration, the position value of the AG03/1 is set to the programmed calibration value (see chapter 6: Parameter description parameter no. 14). The measuring system is calibrated via Profibus (see chapter 7.6: Parameterization via Profibus parameter no. 970). NOTICE Calibration is only possible when no travel job is active! 4 External gear unit If an external gear unit is used, a factor can be programmed via the parameter no. 11 ü - Numerator (numerator) and parameter no. 12 ü Denominator (denominator), in order to include the gear ratio in position sensing (see also chapter ). Example (see fig. 7): The AG03/1 is operated on a gear with transfer reduction of 5:1. For this purpose, the parameters ü-numerator and ü-denominator must be programmed as follows: Parameter ü - Numerator : 5 Parameter ü - Denominator : 1 AG03/1 (PB) Date: Page 11 of 35 Art.No Mod. status 282/14
12 external 5 revolution gear unit 5:1 1 revolution M AG03/1 with internal drive Gear output Fig. 7: External gear unit Input of an odd gear reduction value is possible according to the following example: Transfer reduction = 3.78 Parameter ü - Numerator : 378 Parameter ü - Denominator : Warnings / Faults The AG03/1 distinguishes between warnings and faults: 5.1 Warnings Warnings do not influence the operation of the positioning drive. Warnings disappear after removing their causes. Possible warnings: Battery voltage for absolute encoder is below limit exchange battery within the next 6 months (see chapter 2.1: system status word bit 12). Motor current beyond the permissible range (see chapter 2.1: System status word bit 13). if this condition lasts longer than 4 s, the AG03/1 will switch to fault. Lag error present (see chapter 2.1: System status word bit 15) AG03/1 cannot reach programmed speed because load is too high. 5.2 Faults Faults induce an immediate stop of the positioning drive. The status-led signalizes the fault status (see installation instructions). Based on the blink code, the cause of the fault can be tracked down (see table 2: Error codes). Furthermore, an existing fault can be recogniozed via ZSW.3 = 1. Faults must be acknowledged after clearing the faults (STW.7 = 1 ). The error messages are entered in the error buffer in the order of their detection. The last 10 fault messages are displayed when the fault buffer is full. The cause of an error can be tracked down with the help of the error codes (see table 2: Error codes). The error buffer is stored in the EEPROM and can be deleted via Profibus Parameter 970 dec. AG03/1 (PB) Date: Page 12 of 35 Art.No Mod. status 282/14
13 5.2.1 Error codes The following table lists possible error causes: Value error buffer Blink code green Status-LED Error description A blinking 1 time supply voltage too low Error condition: Supply voltage <18 V + motor current >200 ma B blinking 2 times blocked drive shaft Error condition: Revolutions per minute < rpm + contouring error C blinking 3 times motor current too high Error condition: Motor current >2.4 A more than 4 s D blinking 4 times output stage temperature too high Error condition: Output stage temperature >90 C E blinking 5 times SIN COS monitoring F blinking 6 times internal error G blinking 7 times intermediate circuit voltage too high Error condition: Intermediate circuit voltage >35 V J blinking 10 times Battery voltage <2.2 V Battery must be replaced Table 2: Error codes 6 Parameter description This chapter describes the parameters of the AG03/1. All parameters are stored in the non-volatile EEPROM, except for parameter no. 24 (target value) and parameter no. 30 (Offset inching 2). * Controller parameters ** Standard parameters Nr. Name 1 Controller parameter P * 2 Controller parameter I * 3 Controller parameter D * Selection / value Default Description P gain of controller: valid for all operating modes (positioning mode, velocity mode, inching operation) Profibus chapter 7.6: parameter no dec I gain of controller: valid for all operating modes (positioning mode, velocity mode, inching operation) Profibus chapter 7.6: parameter no dec D gain of controller: valid for all operating modes (positioning mode, velocity mode, inching operation) Profibus chapter 7.6: parameter no dec 4 a Pos * Acceleration in positioning mode: values in % (100 % 4 U/s²) Profibus chapter 7.6: parameter no dec AG03/1 (PB) Date: Page 13 of 35 Art.No Mod. status 282/14
14 Nr. Name Selection / value 5 v Pos * Default Description 30 Maximum speed in positioning mode: values in revolutions/min gear ratio 48:1 max. 100 rev/min gear ratio 24:1 max. 200 rev/min Profibuschapter 7.6: parameter no dec 6 a - Rot * Acceleration in velocity mode: values in % (100 % 4 U/s²) Profibus chapter 7.6: parameter no dec 7 reserved 8 a - Inch * Acceleration in inching operation 1 /2: values in % (100 % 4 U/s²) Profibus chapter 7.6: parameter no dec 9 v - Inch * Maximum speed in inching operation 1 /2: values in revolutions/min gear ratio 48:1 max. 100 rev/min gear ratio 24:1 max. 200 rev/min Profibus chapter 7.6: parameter no dec 10 Pos- Window ** Positioning mode: positioning window If the actual position of the AG03/1 is within the programmed target value ± this window, this is signalled by setting bit 3 in the system status word of the AG03/1 (see chapter 2.1). Spindle pitch = 0: Information refers to increments Spindle pitch 0: Information refers to travelling distance in 1/100 mm Velocity mode: Velocity window If the actual velocity is within the target velocity ± this window, this is signalled by setting bit 3 in the system status word of the AG03/1 (see chapter 2.1). Profibus chapter 7.6: parameter no dec 11 ü Numerator** Numerator gear ratio: a gear ratio can be programmed here when a gear unit is used (see chapter 4: external gear unit). Profibus chapter 7.6: parameter no dec 12 ü Denominator** 13 Spindle pitch ** 14 Calibration value ** Denominator gear ratio: a gear ratio can be programmed here when a gear unit is used (see chapter 4: external gear unit). Profibus chapter 7.6: parameter no dec Spindle pitch: Spindle pitch = 0: Position value is output in increments (1600 increments per revolution of the driving shaft of the AG03/1). Spindle pitch parameter 0: (when operating the AG03/1 on a spindle) Position value is no longer output as increments, but as travelling distance in 1/100 mm. Target position is entered now as 1/100 mm, too. Spindle pitch value in 1/100 mm. e. g. spindle with a pitch of 2 mm spindle pitch parameter = 200. Profibus chapter 7.6: parameter no dec to Calibration value: Writing a value in this parameter results in the take-over of this value as the absolute position for the AG03/1. Caution! Value must be within the range of the preprogrammed limiting values. Profibus chapter 7.6: parameter no dec AG03/1 (PB) Date: Page 14 of 35 Art.No Mod. status 282/14
15 Nr. Name Selection / value 15 Limit 1 ** to Limit 2 ** to Delta Inch ** to Sense of rotation ** 19 Pos Type ** direct loop + sloop - 20 Operating mode ** Default Description Positioning mode: limit 1 Spindle pitch = 0: Information refers to increments Spindle pitch = 0: Information refers to travelling distance in 1/100 mm If the AG03/1 is beyond the range defined by limit 1 and limit 2 (travel range), travelling will only be possible in the direction of the travel range in inching mode. Caution! Limit monitoring is deactivated if limit 1 is equal limit 2. Please note that there is a jump of the actual position if the resolution of the absolute encoder is exceeded! Velocity mode: no meaning Profibus chapter 7.6: parameter no dec Positioning mode: limit 2 Spindle pitch = 0: Information refers to increments Spindle pitch = 0: Information refers to travelling distance in 1/100 mm If the AG03/1 is beyond the range defined by limit 1 and limit 2 (travel range), travelling will only be possible in the direction of the travel range in inching mode. Caution! Limit monitoring is deactivated if limit 1 is equal limit 2. Please note that there is a jump of the actual position if the resolution of the absolute encoder is exceeded! Velocity mode: no meaning Profibus chapter 7.6: parameter no dec 1600 Delta travelling distance with inching operation 1: indicates the relative travelling distance. positive value positive travelling direction negative value negative travelling direction Spindle pitch = 0: Information refers to increments Spindle pitch = 0: Information refers to travelling distance in 1/100 mm Profibus chapter 7.6: parameter no dec i, e i Counting direction of the measuring system: When the shaft rotates counter-clockwise (view on the clamping ring of the AG03/1). i sense of rotation: positive counting direction e sense of rotation: negative counting direction Profibus chapter 7.6: parameter no dec positioning mode / speed mode direct positioning mode 21 reserved 22 reserved 23 reserved Positioning mode: Type of positioning direct: direct travelling from actual position to target value loop +: travelling to the target value occurs always in positive direction to compensate for spindle play loop -: travelling to the target value occurs always in negative direction to compensate for spindle play. Caution! Loop positioning in positioning mode only. Velocity mode: no meaning Profibus chapter 7.6: parameter no dec Positioning mode: (see chapter 2.2.1: Positioning mode) Velocity mode: (see chapter 2.2.2: Velocity mode) Profibus chapter 7.6: parameter no. 930 dec AG03/1 (PB) Date: Page 15 of 35 Art.No Mod. status 282/14
16 Nr. Name Selection / value 24 Setpoint ** see column Description 25 Stop mode Inching mode 2 ** Default Description 0 Positioning mode: indicates absolute target position. Spindle pitch = 0: Information refers to increments Spindle pitch = 0: Information refers to travelling distance in 1/100 mm Value range: depends on the pre-programmed target values (parameters 15/16) Velocity mode: indicates the target velocity in rev./min. Value range: gear ratio 48:1 max. 100 rev/min gear ratio 24:1 max. 200 rev/min Profibus chapter 7.4: Telegram setup (Data Exchange) Attention! Target value will not be stored in the EEPROM 0/1 0 Stop mode inching mode 2 / touch button mode The stop behaviour of inching mode 2 or touch button operation can be parameterized in different ways. Stop mode = 0 stop with maximum delay Stop mode = 1 stop with pre-programmed delay (parameter no. 8) Profibus chapter 7.6: parameter no dec 26 Inpos mode ** 0/1/2 0 Operating mode: positioning mode: The drive s behaviour upon reaching the positioning window can be determined by this parameter: Inpos mode = 0 position control to setpoint value Inpos mode = 1 position control OFF and short circuit of motor windings Inpos mode = 2 position control OFF and release of drive Velocity mode: no meaning Profibus chapter 7.6: parameter no dec 27 Loop length** Operating mode: positioning mode: Indicates the loop length in increments Velocity mode: no meaning Profibus chapter 7.6: parameter no dec 28 reserved 29 Torque deactivation ** 30 Offset inching 2 ** Operating mode: positioning mode: This parameter determines the threshold of torque deactivation. Percent values are to be entered. Value 125: Torque deactivation disabled. Velocity mode: no meaning Profibus chapter 7.6: parameter no dec Inching operation 2 Witth this parameter, inching speed in inching operation 2 can be influenced. Indication is percentage of parameter no. 9. Caution! This parameter is no stored in the EEPROM. Profibus chapter 7.6: parameter no dec 31 d Pos * Delay in positioning operation: values in % (100 % 4 U/s²) Profibus chapter 7.6: parameter no dec Table 6: Parameter description AG03/1 (PB) Date: Page 16 of 35 Art.No Mod. status 282/14
17 7 Communication via Profibus DP 7.1 General remarks This chapter describes the activation and parameterization of the AG03/1 via Profibus interface. For the pin assignment of the Profibus interface please refer to the installation instructions. 7.2 Interface Profibus DP is an international standardized, open fieldbus standard and is defined in the standards: European Fieldbus Standard EN50170 DIN parts 1 and 3 The fieldbus is used for cyclic data exchange between a master and the subordinate slaves. Masters determine data traffic on the bus and are called active stations. Slaves can only acknowledge received messages or transfer messages to the master upon inquiry. Slaves are called passive stations. The AG03/1 is operated on the Profibus-DP as a slave (passive bus station) and can, therefore, acknowledge messages or send data only upon inquiry from the master. The AG03/1 automatically recognizes the baud rate of the Profibus-DP. The master uniformly sets the baud rate for all devices connected to the Profibus. The AG03/1 supports the following baud rates: 9.6 kbd, 19.2 kbd, kbd, kbd, 500 kbd, 1.5 MBd, 3 MBd, 6 MBd, 12 MBd Line length: Baud rate in kbit/s Line length in m Table 7: Line length Termination of the Profibus-DP line: If the AG03/1 is at the end of the bus, the Profibus connection must be terminated using a defined bus terminator. In the AG03/1 this is accomplished via an internal resistor combination that can be connected via DIP switches SW9 + SW10 (see chapter 7.10: Profibus bus terminator). 7.3 Data exchange The flow charts, control functions and status messages as well as the type of cyclic data traffic between master and AG03/1 (slave) are based on the processes and data structures defined in the document Profibus profile for adjustable speed drives, PROFIDRIVE version 2 (September 1997 issue, PNO order no ). AG03/1 (PB) Date: Page 17 of 35 Art.No Mod. status 282/14
18 7.4 Telegram setup (Data Exchange) During operation (Data exchange orange Profibus-LED is lighting, see installation instructions), 7 data words are cyclically exchanged between a master and the AG03/1. The structure of these data words for cyclic data traffic is called Parameter Process data Object (PPO) in the Profibus profile Adjustable-speed Drives PROFIDRIVE version Parameter Process Data Object Such a Parameter Process data Object (PPO) consists of two parts: Parameter data range (see chapter 7.4.2: Parameter identification value) Any parameter in the AG03/1 can be monitored or changed by means of the PKW telegram portion (parameter identification value). Process data range (see chapter 7.4.3: Process data) Control words and target values (master slave) or status words and actual values (slave master), respectively, can be transferred with the process data. Definition of the Parameter Process data Object A special PPO type with fixed data length (7 data words) has been defined for the AG03/1: PKW (4 words) PZD (3 words) PZD1 PZD2 PZD3 PKE IND PWE STW HSW HSW (master slave) ZSW HIW HIW (slave master) MSW LSW word 1 word 2 word 3 word 4 word 5 word 6 word 7 Fig. 8: PPO setup PKW: Parameter identification value PKE: Parameter identification IND: Index PWE: Parameter value PZD1...3: Process data STW: Control word ZSW: Status word: HSW: Main target value HIW: Main actual value LSW: lowest-value data word MSW: highest-value data word Parameter identification value (PKW) Parameter processing in cyclic data traffic is executed via the PKW portion of the PPO. Here the master formulates a job and sends it to the slave. The master repeats the job until the slave has processed the job and given its reply. The slave makes available the reply until the master formulates a new job. Only one job can be processed at the same time Parameter identification (PKE) The parameter identification PKE consists of a data word, in which the type of the job/reply and the associated parameter number has been coded. AG03/1 (PB) Date: Page 18 of 35 Art.No Mod. status 282/14
19 The parameter identification is made up as follows: PKE (Parameter identification) AK SPM Parameter number (PNU) Fig. 9: PKE setup AK: Job or reply identification, respectively SPM: Toggle bit for spontaneous message function not implemented (status does not matter) PNU: Parameter number Job/reply processing is defined in such a way that the content of the job identification field determines which fields of the PKW interface (index and/or parameter value (PWE)) must be interpreted as well. Job identification (master slave) Reply identification Job Function (possible answers from slave) identification positive negative 0 No job 0 1 Request parameter value 1 or 2 2 Change parameter value (word) 1 3 Change parameter value (double word) 2 4 Request description element 3 7 or 8 5 Change description element 3 6 Request parameter value (array) 4 or 5 7 Change parameter value (array word) 4 8 Change parameter value (double word) 5 9 Request number of array elements 6 Table 8: Job identification The right column, Reply identification, refers to the replies from the slave (see table 9: Reply identification). In the normal case there is a positive reply, in case of a fault the reply is negative. Reply identification (slave master) Reply Function identification 0 No reply 1 Parameter value transferred (word) 2 Parameter value transferred (double word) 3 Description element transferred 4 Parameter value transferred (array word) 5 Parameter value transferred (array double word) 6 Number of array elements transferred 7 Job cannot be executed 8 No authorization for PKW interface Table 9: Reply identification Parameter number (master slave, slave master) This field contains the number of the parameter whose data is transferred in the Parameter Value (PWE) field. AG03/1 (PB) Date: Page 19 of 35 Art.No Mod. status 282/14
20 Sub-index (IND) This field contains the array sub-index in the case of jobs and replies that refer to array elements Parameter value (PWE) This field contains the numerical value of the parameter present in the Parameter Number (PNU) (see chapter 7.6: Parameterization table 15). The PWE transfer of word sizes is realized with word 4 of the PPO, transfer of double word sizes is realized with word 3 and word 4 of the PPO (see fig. 8: PPO setup). In the case of non-executable jobs the slave replies with an error number as described in the table below: No. Meaning 0 illegal parameter number 1 parameter value cannot be changed 2 upper or lower limit exceeded 3 faulty sub-index 4 no array 5 wrong data type 6 no setting permitted (only resettable) 7 description element cannot be changed 8 PPO Write required in IR not available 9 description data not available 10 wrong access group 11 no authorization 12 wrong password 13 text in cyclic traffic not readable 14 name in cyclic traffic not readable 15 no text array available 16 PPO is missing 17 job cannot be executed due to operating state 18 other error 19 date in cyclic traffic not readable Table 10: Error numbers with reply Process data (PZD) In the process data portion all information is transferred, which is exchanged in normal cyclic travelling operation, i. e., control commands, target values from master to drive or status word, respectively, actual values from drive to master. Due to the two operating modes of the AG03/1 (positioning mode and velocity mode) there are different meanings for individual parameters. The process data portion is set up as follows: Data transfer (master slave) PZD target value STW high word low word Fig. 10: Process data master slave Control word (STW) For a description of the control word in positioning mode refer to chapter For a description of the control word in velocity mode refer to chapter AG03/1 (PB) Date: Page 20 of 35 Art.No Mod. status 282/14
21 Target value: The target value consists of 4 bytes and has a different meaning depending on the operating mode: Positioning mode Target value contains the target position applicable to the next travelling job. The value must be in the range of the pre-programmed limiting values (see chapter 7.6: Parameterization, parameter nos 1016/1017)! Velocity mode Target value contains the target velocity value in rev./min. Data transfer slave master PZD actual value ZSW high word low word Fig. 11: Process data slave master Status word ZSW: Description: Positioning mode, see chapter Velocity mode, see chapter Actual value: The actual value consists of 4 bytes and has a different meaning depending on the operating mode: Positioning mode The actual value contains the actual position value Velocity mode The actual value contains the actual velocity 7.5 Functional description of the control units The control and status words are represented as follows: high byte low byte bit number Fig. 12: Representation of control and status words Example (grey background): binary: hex: AG03/1 (PB) Date: Page 21 of 35 Art.No Mod. status 282/14
22 7.5.1 Control word in positioning mode (master slave) Bit Value Designation acc. to PROFIDRIVE AG03/1 description 0 1 ON OFF 1: not active (operational condition) 0 OFF 1 OFF 1: cancellation of positioning job (motor enabled, ready-to-run state) / release from turn-on interlock 1 1 Operating condition OFF 2: not active 0 OFF 2 OFF 2: cancellation of positioning job (motor enabled, ready-to-run state) 2 1 Operating condition Not implemented 0 OFF 3 must be statically set to Operation enabled Enable operation 0 Disable operation Operation disabled Motor decelerates with maximum deceleration and assumes ready-to-run state. Motor remains in control state. 4 1 Operating condition for positioning Must continuously be pending for travel job. Activation of travelling job via edge on bit 6 0 Stop Drive decelerates with maximum deceleration. Current positioning job is discarded. Motor remains in control state. 5 1 Operating condition for positioning Must continuously be pending for executing a travel job. 0 Intermediate stop Drive decelerates from an active travel job with preprogrammed deceleration to n=0 and comes to a standstill with a stop torque. The travel job is not discarded. The travel job is continued after changing to bit 5=1. 6 Edge 0/1 Activate travel job Each edge enables a new travel job with the current target value. 1/0 7 1 Acknowledge Acknowledge fault. Turning on of the AG03/1 will be disabled. 0 no meaning Inching 1 On Condition: Operation is enabled and no active positioning process Drive travels once by delta-inch target value. 0 Inching 1 Off Inching 1 off 9 1 Inching 2 On Condition: Operation is enabled and no active positioning process. Drive travels until Inching 2 is OFF. Direction depends on bit Inching 2 Off Inching 2 off 10 is not supported AG03/1-specific negative travel direction with inching operation 2 0 AG03/1-specific positive travel direction with inching operation 2 Table 11: Control word: Positioning mode AG03/1 (PB) Date: Page 22 of 35 Art.No Mod. status 282/14
23 7.5.2 Status word: Positioning mode (slave master) Bit Value Designation acc. to PROFIDRIVE AG03/1 description 0 1 Ready to turn on Supply voltage for motor and electronics unit applied. 0 Not ready to turn on 1 1 Ready Identical with bit 0. 0 Not ready 2 1 Operation enabled Positioning operation enabled. 0 Operation disabled Positioning operation disabled. 3 1 Error Drive faulty and, therefore, out of operation; turn-on disabled after acknowledgement and successful fault correction. Error code in fault buffer. 0 Faultless 4 1 No OFF 2 No pending OFF 2 command. 0 OFF 2 OFF 2 command pending. 5 1 No OFF 3 Not implemented 0 OFF 3 Statically on Turn-on disabled Restart only via OFF 1 with subsequent On. 0 Turn-on not disabled 7 1 Warning Drive still in operation, no acknowledgement required (Warnings see chapter 5.1). 0 No warning No pending warning or warning has disappeared. 8 1 No lag error No lag error present (see chapter 2.1: system status word bit 15) 0 Lag error 9 1 Guide required Not supported (statically on 1 ). 0 On-site operation 10 1 Target position reached The absolute position value is at the end of a travel job in the positioning window. 0 Outside target position 11 1 Reference point set Function not implemented because it is an absolute 0 No reference point set system (statically on 1 ). 12 Edge 0/1 1/0 Acknowledgement of target value Edge acknowledges that a new positioning job was taken over Drive stands still Signals standstill in case of intermediate stop and stop. 0 Drive travels Travel job is executed 14 1 Limiting value for position exceeded Position limiting value exceeded in positive or negative direction. Travelling possible only via inching operation. 0 Within position limit Position value is within pre-programmed limiting values ready-to-travel AG03/1 is ready-to-travel if operation has been enabled (ZSW.2 = 1 ) 0 not ready-to-travel AG03/1 is not ready-to-travel Table 12: Status word: Positioning mode Supply voltage of the output stage is applied no limits have been exceeded no fault is active no current positioning is active AG03/1 (PB) Date: Page 23 of 35 Art.No Mod. status 282/14
24 7.5.3 Flow chart: Operating mode: Positioning mode Means change from 0 to 1 and back Means change from 1 to 0 and back Start Operating voltage On STW = Fault ZSW.3 = 1 STW.7 = X Bit may be 0 or 1 Ready-to-run ZSW= 0x1x 1x11 x01x 0011 Turn-on disabled ZSW.6 = 1 Enable operation STW = OFF 1 STW.0 = Inching 1/ 2 On STW = o. x Operation enabled ZSW = xx1x 1x11 x Inching 1/ 2 active ZSW = 0x0x 1x1x x Inching Off STW = Ready-to-travel ZSW = 101x 1x11 x Activate travel job STW = STW.6 = or Travel job active ZSW = 000x 1x1x x Intermediate stop STW.5 = 0 Start positioning STW.5 = 1 Travel job inactive ZSW = 101x 1x11 x Fig. 13: Flow chart: Positioning mode AG03/1 (PB) Date: Page 24 of 35 Art.No Mod. status 282/14
25 7.5.4 Control word: Velocity mode (master slave) Bit Value Designation acc. to PROFIDRIVE AG03/1 description 0 1 ON OFF 1: not active (operational condition) 0 OFF 1 OFF 1: Cancellation of travel job (motor enabled, ready-to-run state) / Release from turn-on interlock 1 1 Operating condition OFF 2: not active 0 OFF 2 OFF 2: Cancellation of positioning job (motor enabled, ready-to-run state) 2 1 Operating condition Not implemented 0 OFF 3 must be statically set to Enable operation Enable operation 0 Disable operation Disable operation Motor decelerates with maximum deceleration and assumes ready-to-run state. Motor remains in control state. 4 1 Operating condition Not implemented 0 Disable starting encoder 5 1 Enable starting encoder Not implemented 0 Stop starting encoder 6 1 Enable target value Target value is enabled, drive rotates with preset velocity. 0 Disable target value Drive runs out with pre-programmed deceleration Motor remains in control state. 7 1 Acknowledge Acknowledge fault. Turning on of the AG03/1 will be disabled. 0 no meaning 8 is not supported - 15 Table 13: Control word: Velocity mode AG03/1 (PB) Date: Page 25 of 35 Art.No Mod. status 282/14
26 7.5.5 Status word: Velocity mode (slave master) Bit Value Designation acc. to PROFIDRIVE AG03/1 description 0 1 Ready to turn on Supply voltage for motor and electronics unit applied. 0 Not ready to turn on 1 1 Ready Identical with bit 0. 0 Not ready 2 1 Operation enabled Velocity mode enabled. 0 Operation disabled Velocity mode disabled. 3 1 Error Drive faulty and, therefore, out of operation; turn-on disabled after acknowledgement and successful error correction. Error code in fault buffer. 0 Faultless 4 1 no OFF 2 No pending OFF 2 command. 0 OFF 2 OFF 2 command pending. 5 1 no OFF 3 Not implemented 0 OFF 3 statically on Turn-on disabled Restart only via OFF 1 with subsequent On. 0 Turn-on not disabled 7 1 Warning Drive still in operation, no acknowledgement required (Warnings see chapter 5.1). 0 No warning Drive still in operation, no acknowledgement required. 8 1 Monitoring of required/actual values within tolerance range Actual velocity is within the velocity window of the target velocity. 0 Monitoring of required/actual values outside tolerance range 9 1 Guide required Not supported (statically on 1 ) 0 On-site operation 10 1 f or n reached Not supported (statically on 1 ) 0 Below f or n 11 Device-specific Not supported (statically on 1 ) and Drive stands still Signals standstill at stop. 0 drive travels Drive shaft rotates. 14 Device-specific Not supported (statically on 1 ) 15 1 ready-to-travel AG03/1 is ready-to-travel if operation has been enabled (ZWS.2 = 1 ) no fault is active Supply voltage of the output stage is applied velocity mode is not active (STW.6 = 0 ) 0 not ready-to-travel AG03/1 is not ready-to-travel Table 14: Status word: Velocity mode AG03/1 (PB) Date: Page 26 of 35 Art.No Mod. status 282/14
27 7.5.6 Flow chart: Operating mode: Velocity mode Means change from 0 to 1 and back Start Fault ZSW.3 = 1 Means change from 1 to 0 and back Operating voltage On STW = STW.7 = X Bit may be 0 or 1 Ready-to-run ZSW= x x01x 0011 Turn-on disabled ZSW.6 = 1 Enable operating STW = OFF 1 STW.0 = Operating enabled ZSW = x x x Ready-to-travel ZSW = x x Enable target value STW = Change starget value STW = Travelling ZSW = 00x1 111x x Disable target value STW = Fig. 14: Flow chart: Velocity mode AG03/1 (PB) Date: Page 27 of 35 Art.No Mod. status 282/14
28 7.6 Parameterization via Profibus A parameter number is assigned to every parameter of the AG03/1 that serves to read out or change the parameters by means of the PKW mechanism (see chapter 7.4.2: PKW). Changes of the parameters are stored in the non-volatile EEPROM. If the Profibus master sends illegal values to the AG03/1, this result in an error message (see Table 10: Error numbers with reply). For the meaning of the individual parameters please refer to chapter 6: Parameter description. Parameter Name Access Format Description No. 918 dec 396 hex Profibus Address read word Under this parameter number the preset Profibus address can be read out. 930 dec 3A2 hex Operating mode read / write word PWE = 1: Velocity mode PWE = 2: Positioning mode 945 dec Fault buffer read Array 3B1 hex [10] word 952 dec 3B8 hex 961 dec 3C1 hex 965 dec 3C5 hex Number of faults Hardware version Softwareversion (see chapter 6: parameter no. 21) This parameter is defined as an array with 10 entries. In this array, occurring faults are entered with their fault codes. This fault code can be read out via parameter number and indication of the sub-index (0 to 9). The fault codes are stored in the EEPROM The fault codes are output as ASCII characters from A to E. The fault buffer can be deleted via parameter no. 970 dec. Example: PWE = 41: corresponds to ASCII A For the meaning of the individual characters please refer to chapter 5.2: table 2: error codes. read word Here the number of faults occurring can be read out. The number of faults is stored in the EEPROM. read word The gear reduction of the AG03/1 can be read out. PWE = 2: gear reduction 24:1 PWE = 3: gear reduction 48:1 read word The software version of the AG03/1 can be read out via this parameter, e. g., 0101 hex means version AG03/1 (PB) Date: Page 28 of 35 Art.No Mod. status 282/14
29 Parameter No. 970 dec 3CA hex 1000 dec 3E8 hex 1001 dec 3E9 hex 1002 dec 3EA hex Name Access Format Description Load parameter data record Controller parameter P Controller parameter I Controller parameter D write word* PWE = 1: Set all parameters to default values (bus address is not changed). PWE = 2: Set standard parameters to default value (see chapter 6: Parameter description). Controller parameters are maintained. PWE = 3: Set controller parameters to factory settings. Standard parameters are maintained. PWE = 4: Delete fault counter and fault buffer. PWE = 5: calibrate the AG03/1 PWE is set to zero after successful execution (for default values refer to chapter 6: Parameter description) * In deviation from the definition in chapter Parameter identification (PKE), the command Change parameter value (word, job identifier = 2) is acknowledged by the response identifier = 2, Transfer parameter value (double word). read / write read / write read / write 1003 dec 3EB hex a Pos read / write 1004 dec v Pos read / 3EC hex write 1005 dec a Rot read / 3ED hex write 1006 dec 3EE hex 1007 dec 3EF hex a Inch read / write 1008 dec v Inch read / 3F0 hex write 1009 dec 3F1 hex Pos- Window read / write 1010 dec ü- Numerator read / 3F2 hex write 1011 dec ü Denominator read / 3F3 hex write 1012 dec Spindle pitch read / 3F4 hex write 1013 dec Sense of rotation read / 3F5 hex write word Value range: (meaning: see chapter 6: parameter no. 1) word Value range: (meaning: see chapter 6: parameter no. 1) word Value range: (meaning: see chapter 6: parameter no. 3) word Value range: (meaning: see chapter 6: parameter no. 4) word Value range: gear ratio 24: gear ratio 48: (meaning: see chapter 6: parameter no. 5) word Value range: (meaning: see chapter 6: parameter no. 6) reserved word Value range: (meaning: see chapter 6: parameter no. 8) word Value range: gear ratio 24: gear ratio 48: (meaning: see chapter 6: parameter no. 9) word Value range: (meaning: see chapter 6: parameter no. 10) word Value range: (meaning: see chapter 6: parameter no. 11) word Value range: (meaning: see chapter 6: parameter no. 12) word Value range: (meaning: see chapter 6: parameter no. 13) word PWE = 0: i sense of rotation PWE = 1: e sense of rotation (meaning: see chapter 6: parameter no. 18) AG03/1 (PB) Date: Page 29 of 35 Art.No Mod. status 282/14
30 Parameter No dec Pos- type read / 3F6 hex write 1015 dec 3F7 hex Name Access Format Description 1016 dec 3F8 hex Limit 1 read / write 1017 dec Limit 2 read / 3F9 hex write 1018 dec Calibration value read / 3FA hex write 1019 dec 3FB hex Delta Inch read / write 1020 dec System 3FC hex status word 1021 dec 3FD hex 1022 dec 3FE hex Stop mode Inch2 word PWE = 0: direct PWE = 1: loop + PWE = 2: loop (meaning: see chapter 6: parameter no. 19) reserved Double word Value range: (meaning: see chapter 6: parameter no. 15) Double Value range: word (meaning: see chapter 6: parameter no. 16) Double Value range: word (for the meaning refer to see chapter 6: parameter no. 14 and chapter 3: Calibration) Double Value range: word (meaning: see chapter 6: parameter no. 17) read word System status word of the AG03/1 for the meaning of the individual bits refer to chapter 2.1 System status word read / write Inpos mode read / write word word PWE = 0: Inch2 - stop with maximum delay PWE = 1: Inch2 - stop with pre-programmed delay (meaning: see chapter 6: parameter no. 25) PWE = 0: Position control PWE = 1: short circuit of motor windings PWE = 2: motor released (meaning: see chapter 6: parameter no. 26) Loop length read / 1023 dec word Value range: FF hex write (meaning: see chapter 6: parameter no. 27) 1027 dec Device read word Temperature in 1/10 C 403 hex temperature 1029 dec Motor current read word Current in ma 405 hex 1031 dec general status 407 hex register 1032 dec 408 hex Torque deactivation 1033 dec 409 hex Serial number read Double word 1034 dec date of read Double 40A hex production word read word Indicates the state of supply voltage of the output stage and of torque disable: Bit 4: Supply voltage of output stage Bit 7: torquedeactivation Bit 0-3; 5-6; 8-15: not used Bit x = 1 active Bit x = 0 inactive read / word Value range write (meaning: see chapter 6: parameter no. 29) Reading the serial number dec = serial number Read out date of production Format description (example): hex = = DDMMJJJJ Offset inching 2 read / Double 1035 dec word Value range B hex write (meaning: see chapter 6: parameter no. 30) 1036 dec Position value read Read out position value 40C hex word 1039 dec 40F hex d-pos read / write word Value range: (meaning: see chapter 6: parameter no. 31) 1040 dec Supply voltage read word Voltage in 1/10 V 410 hex output stage 1041 dec 411 hex Supply voltage control read word Voltage in 1/10 V AG03/1 (PB) Date: Page 30 of 35 Art.No Mod. status 282/14
31 Parameter No dec 412 hex Name Access Format Description Battery voltage read word Voltage in 1/100 V Table 15: Parameter description Example: read parameter The parameter Calibration value is to be read out: Determination of parameter identification (PKE), consisting of AK, SPM, PNU: 1. Determination of job identification (AK) Job identification = request parameter value = 1 (see table 8): Job identification 2. Determination of parameter number: Parameter number calibration value = 1018 = 3FA h (see table 15). 3. SPM = 0; PKE = 13FA h Parameter identification for the example Read parameter PKE (Parameter identification) Bit Designation AK SPM Parameter number (PNU) Binary value Hex value 1 3 F A Determination of the parameter identification value (PKW): 1. Determination of parameter identification (see above). PKE = 0x13FA 2. Determination of the index: Index (IND) = 0; 3. Parameter value (PWE) = 0 Telegram from master slave: PKW (4 words) PKE IND PWE word 1 word 2 word 3 word 4 0x13FA 0x0000 0x0000 0x0000 Telegram from slave master with correct execution: PKW (4 words) PKE IND PWE word 1 word 2 word 3 word 4 0x23FA 0x0000 0x0000 0x2710 PKE = 23FA h Reply identification = 2 = transfer parameter value (double word) (see table 9: Reply identification) PWE = 2710 h = The current calibration value is AG03/1 (PB) Date: Page 31 of 35 Art.No Mod. status 282/14
32 7.6.2 Example: Write parameter The parameter limit 1 is to be set to : Determination of parameter identification (PKE), consisting of AK, SPM, PNU: 1. Determination of job identification (AK) Job identification = change parameter value double word = 3 = 3 h (see table 8): Job identification 2. Determination of parameter number: parameter number limit 1 = 1016 dec = 3F8 h (see table 15). 3. SPM = 0; PKE = 33F8 h Parameter identification for the example Write parameter PKE (Parameter identification) Bit Designation AK SPM Parameter number (PNU) Binary value hex value 3 3 F 8 Determination of the parameter identification value (PKW) 1. Determination of parameter identification (see above). PKE = 0x33F8 2. Determination of the index: Index (IND) = 0; 3. Determination of the parameter value (PWE) Parameter value (PWE) = = 3D090 h Telegram from master slave: PKW (4 words) PKE IND PWE word 1 word 2 word 3 word 4 0x33F8 0x0000 0x0003 0xD090 Telegram from slave master with correct execution: PKW (4 words) PKE IND PWE word 1 word 2 word 3 word 4 0x23F8 0x0000 0x0003 0xD090 PKE = 23F8 h Reply identification = 2 = transfer parameter value (double word) (see table 9: Reply identification). AG03/1 (PB) Date: Page 32 of 35 Art.No Mod. status 282/14
33 7.7 Diagnosis Standard diagnosis for Profibus DP is supported. Profibus diagnosis consists of 6 bytes with the following contents: Byte Bit Description 0 Diag. station does not exist (set by master) 1 Diag.station not ready Slave not ready for data exchange Byte 1 2 Diag.cfg_Fault Inconsistent configuration data 3 Diag.ext_diag Slave has external diagnosis data 4 Diag.not supported Requested function not supported by slave 5 Diag.invalid slave response (fixes slave to 0) 6 Diag.prm_fault wrong parameterization (ident number, etc.) 7 Diag.master_lock (set by master) Slave has been parameterized by other master 0 Diag.prm_req Slave must be re-parameterized 1 Diag.Stat_diag static diagnosis (byte diag- bits) 2 fixed to 1 Byte 2 3 Diag.WD_ON Response monitoring active 4 Diag.freeze_mode freeze command received 5 Sync_mode sync command received 6 reserved 7 Diag.deactivated (set by master) 0 reserved 1 reserved 2 reserved 3 reserved Byte 3 4 reserved 5 reserved 6 reserved 7 Diag.ext_overflow Byte 4 Diag.master_add Master address after parameterization (FF without parameterization) Byte 5 Ident number high byte Byte 6 Ident number low byte Table 16: Diagnosis bytes Stat_diag: The slave cannot provide valid data due to a condition in the application. As a result, the master requests only diagnosis data until this bit will be reset. The firmware does not support this bit (permanently on 0) Ext_diag: If this bit is set, then a diagnosis entry must be present in the user-specific diagnosis area. This bit is always 0 in the AG03/1, since no user-specific diagnosis data is supported. AG03/1 (PB) Date: Page 33 of 35 Art.No Mod. status 282/14
34 Ext_diag_overflow: This bit is set if more diagnosis data have been provided than would fit the diagnosis data available. This bit is permanently on Profibus address setup The Profibus subscriber addresses can only be set via DIP switches. The 10-pin DIP switch becomes visible after removing the cover. The slave address is entered via switches 1 7 in binary format. The setting of address 127 is internally set into address 126. This is illustrated in the following table: SW1 [2 0 ] SW2 [2 1 ] SW3 [2 2 ] SW4 [2 3 ] SW5 [2 4 ] SW6 [2 5 ] SW7 [2 6 ] set slave address OFF OFF OFF OFF OFF OFF OFF 0 ON OFF OFF OFF OFF OFF OFF 1 OFF ON OFF OFF OFF OFF OFF 2 ON ON OFF OFF OFF OFF OFF 3 : : : : : : : : OFF OFF ON ON ON ON ON 124 ON OFF ON ON ON ON ON 125 OFF ON ON ON ON ON ON 126 ON ON ON ON ON ON ON 126! NOTICE The DIP switch settings are only read when the supply voltage is switched on. Changing the slave address during operation has no effect. AG03/1 (PB) Date: Page 34 of 35 Art.No Mod. status 282/14
35 7.9 Diagnosis LEDs Various operational states are signalled via the diagnosis LEDs. Status LED (green) BUS LED (orange) State Meaning blinking Drive out of order, meaning: see chapter ON The supply voltages of the output stage and control are applied OFF The supply voltages of the output stage and/or control are missing ON Drive is in the data exchange mode OFF Drive is not in the data exchange mode 7.10 Profibus bus terminator The internal bus terminator can be activated via DIP switches : SW9 SW10 Bus terminator OFF OFF deactivated ON ON active NOTICE It should be noted that both DIP switches are always required for correct function of bus termination Device data base and configuration For the AG03/1 a device database file (GSD) named SIKO0AC5.GSD has been created. This file can be included in the device library by means of the configuration tool used, e. g., COM PROFIBUS of the Siemens company (for the procedure to be applied please refer to the documentation of the configuration tool). AG03/1 (PB) Date: Page 35 of 35 Art.No Mod. status 282/14
CB15/CB155. PROFIBUS Module
CB15/CB155 PROFIBUS Module Contents Warning and Caution Notes 1. OVERVIEW 1.1 Description and Features 1.2 Application on a PROFIBUS Link 2. INSTALLATION 2.1 Installing the Module 2.1.1 CB15 Installation
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual CMC-0205820-01 Table of Content 1 Introduction to CMC-PD01... 2 1.1 Product Introduction... 2 1.2 Features... 2 2 Product Profile and Outline...
SMT-BD1/p - CD1-p - User manual. SMT-BD1/p CD1-p gb. PROFIBUS POSITIONER User manual INFRANOR. SMT-BD1/p - CD1-p - User manual 1
SMT-BD1/p CD1-p gb PROFIBUS POSITIONER User manual INFRANOR SMT-BD1/p - CD1-p - User manual 1 2 SMT-BD1/p - CD1-p - User manual WARNING!! This is a general manual describing a series of servo amplifiers
LENORD. +BAUER... automates motion. Fieldbus connection absolute encoders CANopen. Reference. Communication profile DS-301 Device profile DS-406
Fieldbus connection absolute encoders CANopen Communication profile DS-30 Device profile DS-406 LENORD +BAUER... automates motion. Reference D-0R-xCO (.) Right to technical changes and errors reserved.
TwinCAT NC Configuration
TwinCAT NC Configuration NC Tasks The NC-System (Numeric Control) has 2 tasks 1 is the SVB task and the SAF task. The SVB task is the setpoint generator and generates the velocity and position control
Absolute Encoder GEL 235DP
Absolute Encoder GEL 235DP PROFIBUS-DP Fieldbus Connection (Slave) PNO ID: 0B3Eh Reference D-02R-235dp (2.1) Right to technical changes and errors reserved. 2013-07 Device manufacturer and publisher: Lenord,
I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP
I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP 1. Functions An I. S. 1 fieldstation can be equipped with a primary and a redundant central unit (), whereby each has its own independent PROFIBUS
Inwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
Option field bus: without bus with profibus DP. Design-Index (Subject to change)
Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function
HIPERDRIVE HRA71 and HIPER- DRIVE -HUB: Integrated positioning system with absolute distance measurement for format adjustment
HIPERDRIVE HRA7 and HIPER- DRIVE -HUB: Integrated positioning system with absolute distance measurement for format adjustment Convincing benefits: Highly integrated system Low cabling requirements: VDC
Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx
756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang
Belimo Gateway MP to Modbus RTU - UK24MOD
Product information UK24MOD MODBUS RTU Belimo Gateway MP to Modbus RTU - UK24MOD Contents Complete overview 2 Technical data 3 Safety notes 4 Product features 4 Installation and commissioning 4 Electrical
APPENDIX. SureSERVO QUICK START GUIDE. In This Appendix... Quick Start for SureServo Drives...A 2. Tuning Quick Start for SureServo Drives...
SureSERVO QUICK START GUIDE APPENDIX BA In This Appendix... Quick Start for SureServo Drives.............A 2 Spin the Motor......................................A 2 Position Mode Quick Start (Pt & Pr)......................A
Application Note AN-SERV-006
THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT IS SUPPLIED "AS IS", WITHOUT ANY GUARANTEE OF ANY KIND. These documents are provided by our technical support department to assist others.
DeviceNet Bus Software Help for Programming an Allen Bradley Control System
FBP FieldBusPlug V7 DeviceNet Bus Software Help for Programming an Allen Bradley Control System DeviceNet Software Help for Programming an Allen Bradley Control System Contents Page General Purpose...
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
EVBIKE LCD Display Control User Guide. EVBIKE LCD Display Control User Guide WWW.EVBIKE.CZ - 1 -
EVBIKE LCD Display Control User Guide WWW.EVBIKE.CZ - 1 - Table of Contents: 1) Description of the individual components and installation 2) Description of the measured quantities and user control display
SIMOCODE ES Online Help. SIMOCODE pro. SIMOCODE ES V12 Online Help. Tooltips SIRIUS + SIMOCODE. General information. Device configuration
SIMOCODE ES Online Help Tooltips SIRIUS + SIMOCODE 1 General information 2 SIMOCODE pro Programming and Operating Manual Device configuration 3 Diagnostics & Online 4 Parameterization of the modules 5
B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x
B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with
BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.
BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER Installation, Operation, and Maintenance Instructions Manual No. M06-512 SPECIALISTS IN THE MEASUREMENT AND CONTROL OF VISCOSITY BROOKFIELD
RPDO 1 TPDO 1 TPDO 5 TPDO 6 TPDO 7 TPDO 8
EN ZC - 6DI8DO CANopen I/O Module 6 Digital Input 8 Digital Output Or 8 Counters (3 bit) 8 Digital input 8 Digital output User Manual Contents: Features PDOs PDO Type Emergency Message Functional Diagrams
ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1
Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program
CPW Current Programmed Winder. Application Handbook. Copyright 2002 by Eurotherm Drives, Inc.
CPW Current Programmed Winder Application Handbook Copyright 2002 by Eurotherm Drives, Inc. All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted, in
ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program
ACS800 Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program Master/Follower Application Guide Supplement to Firmware Manual ACS800 Standard Application
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
AKD EtherNet/IP Communication
AKD EtherNet/IP Communication Edition August 2012, Revision C Valid for firmware version 1.7 Patents Pending Part Number 903-200008-00 Keep all manuals as a product component during the life span of the
CMMP Function Activation of Multiturn Encoder for Endless Positioning
Application Note CMMP Function Activation of Multiturn Encoder for Endless Positioning Using CMMP-AS in combination with EMMS-AS and multiturn encoders as permanent stored position mode with multiturn
SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application
SINAMICS DCM DC converters from 6 kw to 2500 kw for variable-speed direct-current drives Edition 01-12/2010 SINAMICS drives SINAMICS DCM Compact User Manual Legal information Warning notice system This
Light scene push button 8gang comfort flush-mounted 751688xx
751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional
Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1
Introduction 1 Connecting the drive unit to the PC 2 Startdrive SINAMICS Getting Started - SINAMICS Startdrive Getting Started Creating a project 3 Going online and incorporating devices 4 Commissioning
DeviceNet Communication Manual
DeviceNet Communication Manual Soft-Starter Series: SSW-07/SSW-08 Language: English Document: 10000046963 / 00 03/2008 Summary ABOUT THIS MANUAL... 5 ABBREVIATIONS AND DEFINITIONS... 5 NUMERICAL REPRESENTATION...
ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation
x - + - + x L L L AC SO 4-45 A DC SO 4- A ServoOne Specification x 9 - + - + x 7 x 8 X 8 Option - Technology x 6 TTL Encoder / TTL Encoder simulation Specification ServoOne Specification Option - Technology
NX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
EnDat 2.2 Bidirectional Interface for Position Encoders
Technical Information EnDat 2.2 Bidirectional Interface for Position Encoders Digital drive systems and feedback loops with position s for measured value acquisition require fast data transfer with high
Absolute rotary encoder GEL 235EC
Absolute rotary encoder GEL 235EC EtherCAT fieldbus interface Reference D-02R-235EC (1.1) Right to technical changes and errors reserved. 2011-11 Device manufacturer and publisher: Lenord, Bauer & Co.
Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S 2.300.2. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX Universal Dim Actuator, MDRC UD/S 2.300.2 Intelligent Installation Systems ABB UD/S 2.300.2 Universal Dim Actuator, MDRC This manual describes the function of the Universal
Analog Servo Drive 25A8
Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit
Parameterizing options. 8.1.1 Parameterization options based on the communication protocols used
Setting module parameters 8 PARAMETERIZATION 8.1 Parameterizing options 8.1.1 Parameterization options based on the communication protocols used Many fieldbuses currently in use do not have sufficient
DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual
DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Manual page 1 rev 1.33 COPYRIGHT 2007 ARCUS, ALL RIGHTS RESERVED First edition, June 2007 ARCUS TECHNOLOGY copyrights this document.
Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April 2015 1SFC132089M0201 1
Softstarters Type PSTX Fieldbus communication, Built-in Modbus RTU 1SFC132089M0201 April 2015 1SFC132089M0201 1 1 Modbus RTU The Modbus protocol is a fieldbus protocol that provides full control and status
Cover. SEB SIMOTION Easy Basics. Collection of standardized SIMOTION basic functions. FAQ April 2011. Service & Support. Answers for industry.
Cover SEB SIMOTION Easy Basics Collection of standardized SIMOTION basic functions FAQ April 2011 Service & Support Answers for industry. 1 Preface 1 Preface The SEB is a collection of simple, standardized
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
Series 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
ABB i-bus EIB Logic Module LM/S 1.1
Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B0875-2.1 en
MP85 / MP85DP Data sheet MP85 MP85DP Special features - 100% quality control of the production process - Universal twin-channel amplifier for many of the usual market sensors - Powerful algorithms for
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
ABB Drives. Protocol Manual - Modbus/TCP Ethernet Adapter Module FENA-01
ABB Drives Protocol Manual - Modbus/TCP Ethernet Adapter Module FENA-01 Ethernet Adapter Module - Modbus/TCP FENA-01 Protocol Manual 3AUA0000022989 REV B EN EFFECTIVE: 2009-11-01 2009 ABB Oy. All Rights
GSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.
Electronic Power Control
Service. Self-Study Programme 210 Electronic Power Control Design and Function With the Electronic Power Control system, the throttle valve is actuated only by an electric motor. This eliminates the need
Expat kiss_fft gsoap smartgwt Linux Qt md5 zlig log 4cpp sqlite gcc/g++/libc/libc++ gwt
1 FAG Industrial Services GmbH Kaiserstraße 100 52134 Herzogenrath Germany +49 (0) 2407 9149-66 +49 (0) 2407 9149-59 [email protected] Web www.schaeffler.comservices All rights reserved.
Setting up the DeskCNC controller.
1) Determine the steps to linear motion ratios for each axis. 2 2) Determine Maximum velocity (speed). 3 3) Setting up the software Machine Tab 4 4) Setting up the software DeskCNC Setup Tab 5 5) Setting
Copley Camming User Guide
Copley Camming User Guide P/N 95-00501-000 Revision 2 June 2008 Copley Camming User Guide. TABLE OF CONTENTS About This Manual... 5 1: Operational Overview... 7 1.1: Host System Requirements... 8 1.2:
EDSVS9332S EXT.FZ9. Global Drive. Ä.FZ9ä. System Manual. (Extension) 9300 0.37... 75 kw. EVS9321xS... EVS9332xS. Servo inverter
EDSVS9332S EXT.FZ9 Global Drive Ä.FZ9ä System Manual (Extension) 9300 0.37... 75 kw EVS9321xS... EVS9332xS Servo inverter Contents 1 Preface.............................................................
4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)
4511 MODBUS RTU Configuration Manual HART transparent driver No. 9107MCM100(1328) 9107 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and
Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX Data Logging Unit BDB/S 1.1 Intelligent Installation Systems ABB This manual describes the function of the Data Logging Unit BDB/S 1.1. Subject to changes and errors excepted.
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
Jena er Antriebstechnik. GmbH. 1. Introduction. 2. Properties. 3. Hardware. 4. Baud Rates. Brief Instructions - CANopen Interface
Project : ECOSTEP 100/200 Application Note No. 23 Page 1 of 10 Prepared by: Henrik Bräutigam Operation of ECOSTEP at CANopen Bus Date: 05-01-05 Brief Instructions - CANopen Interface 1. Introduction The
MR-J3-xxBS with QD77MS. Get started with QD77MS-module/ MR-J3-BS servos. Dokmall_sv, 001110
MR-J3-xxBS with QD77MS KSS 2013-02-15 - - 1 (26) Index 1. Function and use... 3 2. About this document... 3 3. Installing the equipment... 3 3.1. MR-J3-BS Servo amplifier...3 3.2. QD77MS External input
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
How To Use An American Zw.Com V20-20 (V20) V20 (Veu) V2.20 (Femalese) V1.2.2 (V2.1) V3.
Cover SINAMICS V: Speed Control of a V20 with S7-1200 via USS Protocol in TIA Portal SINAMICS V20, SIMATIC S7-1200 Short Documentation November 2012 Applications & Tools Answers for industry. Siemens Industry
Tebis application software
Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices WYC81xQ
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
User Manual Software for DSL Digital Speed Switch
User Manual Software for DSL Digital Speed Switch Software version from 1.0.1 Baumer Hübner GmbH Max-Dohrn-Str. 2+4 D-10589 Berlin Phone +49 (0)30 690 03-0 Fax +49 (0)30 690 03-104 [email protected]
Stepper motor I/O. Application Note DK9222-0410-0014 Motion Control. A General information on stepper motors
Stepper motor Keywords Stepper motor Fieldbus Microstepping Encoder Phase current Travel distance control Speed interface KL2531 KL2541 Part A of this Application Example provides general information on
S4000TH HART. HART Communication Manual
HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by General
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015
Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) The standard tuning values used in ADVANCED Motion Controls drives are conservative and work well in over 90%
Identification System. FC 44 Function for ASM 450 With Supplements for FB 240. Contents. General Features Hardware Description of ASM 450
MOBY FC 44 Function for ASM 450 With Supplements for FB 240 Technical Description Identification System Contents General Features Hardware Description of ASM 450 Specifications of the FC 44 BEDB Command
Description. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
ANR-PRF. INSTRUCTION MANUAL IM157-U-A v0.5 COMMUNICATION PROTOCOL ANR MULTIFUNCTION ANALYZER PROFIBUS DP-V0
INSTRUCTION MANUAL IM157-U-A v0.5 ANR-PRF COMMUNICATION PROTOCOL ANR MULTIFUNCTION ANALYZER PROFIBUS DP-V0 PROFIBUS AND ANR-PRF Profibus-DP is a multi-master systems. In the networks it s possible to have
Series 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
Small Optical Encoder Modules 480lpi Digital Output. Features. Applications VCC 3 CHANNEL A 2 CHANNEL B 4 GND 1
HEDS-9730, HEDS-9731 Small Optical Encoder Modules 480lpi Digital Output Data Sheet Description The HEDS-973X is a high performance incremental encoder module. When operated in conjunction with either
Movement/monitoring 1307/1.0 (6325xx)
/monitoring 1307/1.0 (6325xx) General In the following the device will be referred to as the movement detector. The movement block will only switch off when there is no more movement in front of the device
Transmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
Technical Support Bulletin Nr.18 Modbus Tips
Technical Support Bulletin Nr.18 Modbus Tips Contents! Definitions! Implemented commands! Examples of commands or frames! Calculating the logical area! Reading a signed variable! Example of commands supported
GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0
GE Power Controls = FIELDBUS APPENDIX PROFIBUS DP = Doc. No.: ASTAT Plus PB_Appendix-v0 Fieldbus Appendix: PROFIBUS DP 1 Fieldbus Introduction...... 2 1.1 Introduction to Profibus-DP... 2 1.2 Network Overview...
A1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
RF Etch Monitor. Introduction
RF Etch Monitor Introduction A newly designed RF Matching Controller & RF Etch Monitor replaces the old OEM design of the RF Matching Controller and the RF Etch Monitor. OEM RF Matching Controller: - Analog
Software User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide
Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Sensors LCD Real Time Clock/ Calendar DC Motors Buzzer LED dimming Relay control I2C-FLEXEL PS2 Keyboards Servo Motors IR Remote Control
ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1
Product Manual ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1 Intelligent Installation Systems This manual describes the function of the Switch
IBM Emulation Mode Printer Commands
IBM Emulation Mode Printer Commands Section 3 This section provides a detailed description of IBM emulation mode commands you can use with your printer. Control Codes Control codes are one-character printer
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
MI4 - Operator Panel : Engineering
MI4 - Operator Panel : Engineering MI4 - Operator Panel : Engineering Overview MI4 Text Operator Panel MI4 Graphic Operator Panel MI4 Touch Operator Panel Communication modules Accessories MI4-CFG-1 Engineering
Kurz Instruments Inc. Document 360209-AV Document Title: MFTB Event Code Definitions. MFT B-Series Event Codes
MFT B-Series Event Codes The MFT B-series status information is contained in a 4-byte long word (32-bit) Event Code. This Event Code provides a bit-wise mapping of the status of the flow meter with each
2354235 11/2008. Altivar 61/71. Profibus DP. User manual 11/2009. www.schneider-electric.com
2354235 11/2008 Altivar 61/71 Profibus DP User manual 11/2009 1755873 www.schneider-electric.com Contents Before you begin 4 Documentation structure 5 Introduction 6 Presentation 6 Notation 6 Hardware
WINDOW's Programming Software USER MANUAL
www.danahermotion.com High frequency inverter ACO5000 by ACOMEL WINDOW's Programming Software USER MANUAL DANAHER MOTION S.A. La Pierreire 2, CH-1029 Villars-Ste-Croix Telephone +41 21 631 33 33, Telefax
Push button 3gang standard flush-mounted 751633xx
Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
Data Sheet 10/68-2.40-EN. Contrac power electronics Customer specific settings
Data Sheet 10/68-2.40-EN Contrac power electronics Customer specific settings Contrac Electronics Customer Specific Settings 10/68-2.40 EN Order Information Contrac Electronics Code EUR Bus tag No bus
User Manual. AS-Interface Programmer
AS-Interface Programmer Notice: RESTRICTIONS THE ZMD AS-INTERFACE PROGRAMMER HARDWARE AND ZMD AS-INTERFACE PROGRAMMER SOFTWARE IS DESIGNED FOR IC EVALUATION, LABORATORY SETUP AND MODULE DEVELOPMENT ONLY.
Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction 1. 2. Software Installation 2
1. Introduction 1 2. Software Installation 2 2.1 System Requirements 2 2.2 TroxMConnect Installation 2 2.3 Connection to the PC 3 3. TroxMConnect Description 4 3.1 Starting the Software 4 3.2 Layout 4
2011, The McGraw-Hill Companies, Inc. Chapter 3
Chapter 3 3.1 Decimal System The radix or base of a number system determines the total number of different symbols or digits used by that system. The decimal system has a base of 10 with the digits 0 through
Actuators and positioning drives
Actuators and positioning drives distributed by www.laumans.com Actuators and positioning drives FlexiDrive product range type MDBA 42 MSQA 46 MSAA 42 Actuator Actuator Actuator motor brush DC motor brush
VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating
GB PKN10 serial node with colour LCD display User s manual Bač 49a, 6253 Knežak, SLOVENIA tel: ++ 386 5 753 2006 fax: ++ 386 5 753 2007 email: [email protected] http://www.secelectro.com SEC Electronics