Transmission Electron Microscopy
|
|
|
- Agatha Gregory
- 9 years ago
- Views:
Transcription
1 Transmission Electron Microscopy Wacek Swiech, Honghui Zhou, Jim Mabon, Changqiang (CQ) Chen and Matt Bresin Frederick Seitz Materials Research Laboratory University of Illinois at Urbana-Champaign
2 Outline 1. Introduction to TEM 2. Basic Concepts 3. Basic TEM techniques Diffraction Bright Field & Dark Field TEM imaging High Resolution TEM Imaging 4. Scanning Transmission Electron Microscopy (STEM) 5. Aberration-corrected STEM / TEM & Applications 6. Spectroscopy X-ray Energy Dispersive Spectroscopy Electron Energy-Loss Spectroscopy 7. In-Situ TEM 8. Summary
3 Why Use Transmission Electron Microscopy? Optical Microscope Transmission Electron Microscope (TEM) High Resolution TEM Resolution 200 kev electrons l: Å < 500 nm A N is 0.95 with air up to 1.5 with oil Resolution limit: ~100 nm R = 0.66(C s λ 3 ) 1/4 Resolution limit: ~0.25 nm Sample thickness requirement: Thinner than 500 nm High quality image: <20 nm TEM is ideal for investigating thin foil, thin edge, and nanoparticles
4 e- x 10^3 Basic Concepts Electron-Sample Interaction 1. Transmitted electrons (beam) 2. Diffracted electrons (beams) (Elastically scattered) 3. Coherent beams 4. Incoherent beams 5. Inelastically scattered electrons 6. Characteristic X-rays Incident high-kv beam Specimen X-rays Incoherent beam (STEM) Diffracted beam Coherent beam Transmitted beam Inelastically scattered electrons magnetic prism TEM can acquire images, diffraction patterns, spectroscopy and chemically sensitive images at sub-nanometer to nanometer resolution.
5 Structure of a TEM Gun: LaB 6, FEG keV Gun and Illumination part TEM Sample Objective lens part View screen Mode selection and Magnification part
6 How does a TEM Obtain Image and Diffraction? Incident Electrons Sample < 500 nm Objective Lens Back Focal Plane Back Focal Plane Structural info First Image Plane First Image Plane u v Morphology 1 _ = u v f Object Image Conjugate planes View Screen
7 Electron Diffraction I SOLZ FOLZ d ZOLZ q Zero-order Laue Zone (ZOLZ) First-order Laue Zone (FOLZ). Bragg s Law 2 d sin q = nl Wavelength X-ray: about 1A Electrons: 100kV High-order Laue Zone (HOLZ) l is small, Ewald sphere (1/l) is almost flat Ewald Sphere
8 Electron Diffraction II Diffraction patterns from single grain or multiple grains 50 nm Single crystal Polycrystal Amorphous
9 Selected Area Electron Diffraction (SAED) Major Diffraction Techniques 1) Selected-Area Electron Diffraction 2) NanoArea Electron Diffraction 3) Convergent Beam Electron diffraction Example of SAED SAED aperture Selected-area aperture J.G. Wen, A. Ehiasrian, I. Petrov
10 Selected Area Electron Diffraction (SAED) 1. Illuminate a large area of the specimen with a parallel beam. 2. Insert an aperture in the first image plane to select an area of the image. 3. Focus the first imaging lens on the back focal plane Al matrix Al-Cu matrix L. Reimer and H. Kohl, Transmission Electron Microscopy, Physics of Image Formation, 2008.
11 Selected Area Electron Diffraction Advantages 1. Can observe a large area of specimen with a bright beam 2. Since the image plane is magnified, can easily select an area with an aperture A 50 mm aperture can select a 2 mm area 3. Useful to study thick films, bulk samples, and in-situ phase transformations Spherical Aberrations Disadvantages 1. Cannot select an area less than ~1 mm due to spherical aberrations and precision in aperture position 2. Difficult to record diffraction from individual nanoparticles or thin films Selected Area Aperture
12 Nanoarea Electron Diffraction (NAED) Diffraction from a single Au rod 55 nm nanoprobe Technique 1. Focus the beam on the front focal plane of the objective lens and use a small condenser aperture to limit beam size 2. A parallel beam without selection errors A 10 mm aperture can form a ~ 50 nm probe size 3. Useful to investigate individual nanocrystals and superlattices Disadvantages A. B. Shah, S. Sivapalan, and C. Murphy 1. Very weak beam difficult to see and tilt the sample 2. More complex alignment than conventional TEM 3. High resolution images are difficult to obtain Need to switch between NAED and TEM modes)
13 Nanoarea Electron Diffraction 5 mm condenser aperture 30 nm M. Gao, J.M. Zuo, R.D. Twesten, I. Petrov, L.A. Nagahara & R. Zhang, Appl. Phys. Lett. 82, 2703 (2003) J.M. Zuo, I. Vartanyants, M. Gao, R. Zhang and L.A. Nagahara, Science, 300, 1419 (2003) This technique was developed by CMM
14 Aperture-Beam Nanoarea Electron Diffraction a) b) CeO S 011 S 020 S 002 C 111 C 220 C SrTiO 3 2 nm 5 n m v Condenser Aperture u Sample Conjugate planes 5 n m 20 mm condenser aperture 20 nm probe size This technique was developed by CMM
15 Applications of Electron Diffraction Tilting sample to obtain 3-D structure of a crystal Lattice parameter, space group, orientation relationship New materials discovered by TEM Quasi-crystal Carbon Nanotube 5-fold symmetry To identify new phases, TEM has advantages: 1) Small amount of materials 2) No need to be single phases 3) Determining composition by EDS or EELS 1, 2, 3, 4, 6-fold symmetry No 5-fold for a crystal Helical graphene sheet Disadvantage: needs experience More advanced electron diffraction techniques
16 Convergent Beam Electron Diffraction (CBED) Parallel beam Convergent-beam Sample Sample Back Focal Plane Large-angle bright-field CBED SAED CBED 1. Point and space group 2. Lattice parameter (3-D) strain field Bright-disk 3. Thickness 4. Defects Dark-disk Whole-pattern
17 Major Imaging Techniques Major Imaging Contrast Mechanisms: 1. Mass-thickness contrast 2. Diffraction contrast 3. Phase contrast 4. Z-contrast Mass-thickness contrast 1) Imaging techniques in TEM mode a) Bright-Field TEM (Diff. contrast) b) Dark-Field TEM (Diff. contrast) c) Weak-beam imaging hollow-cone dark-field imaging d) Lattice image (Phase) e) High-resolution Electron Microscopy (Phase) Simulation and interpretation 2) Imaging techniques in scanning transmission electron microscope (STEM) mode 1) Z-contrast imaging (Dark-Field) 2) Bright-Field STEM imaging 3) High-resolution Z-contrast imaging (Bright- & Dark-Field) 3) Spectrum imaging 1) Energy-Filtered TEM (TEM mode) 2) EELS mapping (STEM mode) 3) EDS mapping (STEM mode)
18 TEM Imaging Techniques Phase Contrast Image I. Diffraction Contrast Image: Contrast related to crystal orientation [111] Kikuchi Map [112] [001] [001] [110] Two-beam condition Transmitted beam Application: Morphology, defects, grain boundary, strain field, precipitates Diffracted beam
19 TEM Imaging Techniques II. Diffraction Contrast Image: Bright-field & Dark-field Imaging Sample Sample Objective Lens T D Aperture Back Focal Plane Diffraction Pattern Two-beam condition Bright-field Image First Image Plane Dark-field Image Bright-field Dark-field
20 TEM Imaging Techniques II. Diffraction Contrast Imaging At edge dislocation, strain from extra half plane of atoms causes atomic planes to bend. The angle between the incident beam and a few atomic planes becomes equal to the Bragg Angle Θ B. Dislocations & Stacking Faults Bright Field Image Specimen Principal Plane Near dislocations, electrons are strongly diffracted outside the objective aperture Objective Aperture R. F. Egerton, Physical Principles of Electron Microscopy, Diffracted Transmitted Beam Beam
21 Weak-beam Dark Field Imaging High-resolution dark-field imaging Near Bragg Condition g S g Taken by I. Petrov Exact Bragg condition Weak-beam means Large excitation error Planes do not satisfy Bragg diffraction Possible planes satisfy Bragg diffraction 1g 2g 3g Experimental weak-beam C.H. Lei Bright-field Weak-beam Dislocations can be imaged as 1.5 nm narrow lines
22 TEM Imaging Techniques II. Diffraction Contrast Image Two-beam condition for defects Howie-Whelan equation df 0 pi = f dz g exp{2pi(sz+g.r)} x g Dislocations Use g.b = 0 to determine Burgers vector b Stacking faults Phase = 2 p g R Each stacking fault changes phase 2 -p 3 Diffraction contrast images of typical defects Sample g Dislocations Dislocation loop Stacking faults
23 Lattice Beam Imaging Two-beam condition Many-beam condition [001] M. Marshall C.H. Lei
24 Lattice Imaging Delocalization effect from a Schottky-emission gun (S-FEG) From a LaB 6 Gun Field-Emission Gun Lattice image of film on substrates
25 High Resolution Transmission Electron Microscopy (HRTEM) 1 Df sch 2 Df sch f(x,y) = exp(isv t (x,y)) ~1 + i s V t (x,y) V t (x,y): projected potential Scherzer defocus 1 Df sch = (C s l) 2 Resolution limit 1 r sch = 0.66 C 4 s l Scherzer Defocus: Positive phase contrast black atoms 2 Scherzer Defocus: ("2nd Passband" defocus). Contrast Transfer Function is positive Negative phase contrast ("white atoms") Contrast transfer function J.G. Wen Simulation of images Software: Web-EMAPS (UIUC) MacTempas
26 e- x 10^3 Scanning Transmission Electron Microscopy Focused e-beam Dark-field Bright-field Probe size nm STEM x-rays Thickness <100 nm Incoherent Scattering i.e. Rutherford Coherent Scattering (i.e. Interference) Technique 1. Raster a converged probe across and collect the integrated signal on an annular detector (dark field) or a circular detector (bright field). 2. An incoherent image is chemically sensitive (Z-contrast) under certain collection angles 3. Annular dark field (ADF) STEM is directly interpretable and does not have contrast reversals or delocalization effects like HRTEM 4. STEM resolution is determined by the probe size, which is typically 0.2 to 0.5 nm for a modern FEG STEM. magnetic prism Inelastically scattered electrons 5. Since STEM images are collected serially, the resolution is typically limited by vibrations and stray fields
27 e- x 10^3 SEM vs STEM SEM Primary e-beam kev backscattered electrons STEM Primary e-beam kev x-rays secondary electrons <50 ev Auger electrons x-rays Probe size nm Thickness <100 nm Incoherent Scattering i.e. Rutherford Dark-field 1 mm Bright-field Coherent Scattering (i.e. Interference) STEM technique is similar to SEM, except the specimen is much thinner and we collect the transmitted electrons rather than the reflected electrons magnetic prism Inelastically scattered electrons
28 TEM vs ADF-STEM Ge quantum dots on Si substrate Ir nanoparticles 1. STEM imaging gives better contrast 2. STEM images show Z- contrast TEM Z q 10nm 5 nm ADF-STEM Annular dark-field (ADF) detector I Z 2 Z-contrast imaging Z-contrast image J.G. Wen 5 nm L. Long
29 ADF STEM Applications Superlattice of LaMnO 3 -SrMnO 3 -SrTiO 3 Dopant atoms in Si A. B. Shah et al., 2008 P. M. Voyles et al., 2002
30 Bright Field STEM vs ADF STEM 40kX Si Ge Superlattice 1Mx 15Mx Ge x Si 1-x Si 40kX 1Mx 15Mx Ge x Si 1-x Si
31 1.3 mm ± 10 nm Spherical Aberration 2.4 m Since 1936, Scherzer proved that spherical and chromatic aberrations would ultimately limit the resolution of the electron microscope. The method to correct aberrations was well known, but experimental aberration correctors were not successful until ~1998 due to complexities in alignment and lack of computing power.
32 Spherical Aberration Correction C s + ( C s ) = 0 Before correction After correction
33 Spherical Aberration Corrector for TEM & STEM Hexapole C s Corrector Optical Axis Hexapole 1 Round Lens 1 Round Lens 2 N C s < 0 Uli Dahmen NCEM Max Haider CEOS, Germany Hexapole 2 N Harold Rose Univ. of Tech. Darmstadt e-beam
34 Spherical Aberration Corrector for STEM Quadrupole-Octupole C 3 -C 5 corrector First sub-å image resolved in a STEM Ondrej Krivanek Nion Company P. E. Batson et al., Nature, 2002.
35 JEOL JEM2200FS with Probe UIUC The STEM can obtain 1 Å spatial resolution Multilayer wall Diffuser Piezo Stage Only if the instabilities of the room are controlled
36 Spherical Aberration Correction Image corrector Probe corrector JEOL 2010F C s = 1 mm Probe size 0.3 nm JEOL 2200FS with probe corrector Probe size 0.1 nm
37 Improved Resolution and Contrast with C s Corrector 63 pm Aberration correction combined with a high stability environment and high quality specimens allow for atomic resolution imaging over a large area. 4k x 4k image shown.
38 Sub-Å test using GaN film along [211] zone axis TEAM Microscope at LBNL 63 pm Annular dark field STEM image of hexagonal GaN [211] Fourier transform of the image; image Fourier components extend to below 50 pm.
39 New Applications Possible Only with Aberration Correction Ronchigram 1. Better Contrast for STEM Imaging with smaller probe 2. Reduced delocalization for HRTEM imaging 3. Sub-2Å resolution imaging at low voltage ( kv) for TEM and STEM X more probe current in the STEM for EELS and EDS spectroscopy
40 Analytical (Scanning) Transmission Electron Microscopy 40 X-ray Energy Dispersive Spectroscopy Characteristic X-rays Bremsstrahlung X-rays Incident High-kV Beam Specimen Secondary electrons (SE) Back scattered electrons (BSE) Auger Electrons Elastically scattered electrons Forward Scattered electrons Inelastically scattered electrons Electron Energy Loss Spectroscopy
41 EDS and EELS in STEM Mode with Aberration Correction 41 ~ 1-10 nm Further refined probe Down to ~ nm Carries more current Spatially Resolved Analysis Sub nanometer in aberration-corrected STEM!
42 Some relevant transition events explored in EELS and EDS X-ray Energy Loss David Muller 2006: EDS: named by the initial core-hole state, e.g., Kα: 2p 1s EELS: named by the initial state, e.g., L 3 : 2p 3/2 [3S 1/2, 3d 3/2, 3d 5/2 ]
43 SEM X-ray Energy Dispersive Spectroscopy in STEM STEM Masashi Watanabe: X-ray Energy-Dispersive Spectrometry in Scanning Transmission Electron Microscopes in Scanning Transmission Electron Microscopy Imaging and Analysis reproduced from Williams and Carter: Transmission electron microscopy (2009) To High enhance spatial the resolution detection (~ nm sensitivity compared with ~ μm in SEM) refined incident probe Tilt the sample for a more efficient collection significantly reduced interaction volume (directly related to the specimen thickness) Use a higher probe current Use an aberration corrected STEM Degraded analytical sensitivity significantly reduced interaction volume (directly related to the specimen thickness) More collection probe limited current by can microscope be applied column in a detector similar probe configuration dimension (0.3 sr out of 4 π sr)
44 X-ray Energy Dispersive Spectroscopy Applications TEM mode spot, area STEM mode spot, line-scan and 2-D mapping Spatial resolution ~ 1 nm Line scan 2-D mapping HAADF voids Area Mapping Au Fe Ti Mo A B Ti Al A Cr Nb B Si Al Ga Au Ti Ti 0.85 Nb 0.15 metal ion etch A. Ehiasrian, I. Petrov Mo L. Wang
45 e- x 10^3 Electron Energy Loss Spectroscopy Electron Spectrometer 17/1686/spectprism.jpg Post-column Gatan Imaging Filter (GIF) In-column JEOL Omega-type Energy filter Gatan Imaging Filter (GIF)
46 Electron Energy Loss Spectrum ZLP Low-loss Ti-L Core-loss O-K ~ 50 ev Mn-L x100 La-M Zero-loss (ZLP) Energy Loss (ev) Low-loss spectrum (< 50 ev) due to interactions with weakly bound outer-shell electrons Plasmon peak (oscillations of weakly bound electrons) Inter- and Intra-Band transitions Core-loss spectrum (> 50 ev) due to interactions with tightly bound inner-shell electrons Inner shell ionization
47 Fe 2 O 3 Spectrum Comparison between EELS and EDS O-K bkgd Fe-L 3,2 Spectrum Bkgd Edge Energy Loss (ev) ev Fe-L ev Energy (KeV)
48 Correlations of Core-loss EELS Features With Electronic Structure Empty States Conduction/valence bands Core-shell energy levels O-2p O-1s Neighboring atoms Ni-3d Ni-2p Ni-M 3,2 O-K Ni-L 3,2 Gatan: Review of EELS Fundamentals
49 Electron Energy Loss Spectrum Applications Thickness measurement Low-Loss Measuring the collective excitations, e.g., the combined response of the valence electrons and the electron magnetic field. Specimen thickness Optical and electronic properties Polarization response (complex dielectric function) Band structure, e.g., band gap Gatan: Review of EELS Fundamentals Core-Loss Elemental composition: the core-level binding energy is unique Near edge fine structure (ELNES): transition is only possible to local unoccupied states information about electronic structure (i.e., bonding) Extended fine structures (EXELFS): atomspecific radical distribution of near neighbors
50 EELS Near Edge Structure (ELNES) Chemical Bonding π* - Sp 2 bonded C-C Sp 2 bonding C-H bonding C-C Sp 2 bonding C-H* bonding C-C Sp 3 bonding C-H bonding C-C Sp 3 bonding V J Keast, J. Microscopy, 203, 135 (2001)
51 EELS Near Edge Structure (ELNES) Oxidation State of Transition Metal Oxide CaMnO 3 LaMnO 3 Energy Loss (ev) H. Zhou LaMnO 3 M. Varela, et.al., PHYSICAL REVIEW B 79, (2009) CaMnO 3 Chemical Shift L 3 /L 2 ratio (White Line Ratio) O-K edge near edge fine structure (ELNES) (owing to the hybridization between O-2p and the transitional metal 3 d)
52 Counts Counts Counts STEM EELS Spectrum Imaging VO V-L 2 3, Spectrum Image ev VO 1+x V-L 3, ev 6000 NiO Ni-L 3, ev Survey Image Spectrum Image Extracted Spectrum V-L mapping Ni-L mapping Each image pixel carries one EELS spectrum spatial and spectroscopy information are stored together H. Zhou
53 Atomic-column Resolution Spectrum Imaging Atomic-column resolution Spectrum Imaging Ti-L O-K Mn-L La-M Scan Direction DE Electron Energy Loss Substrate Side Ti L O K Mn L La M LaMnO 3 SrTiO 3
54 Atomic-column Resolution Spectrum Imaging La 0.7 Sr 0.3 MnO 3 SrTiO 3 Superlattice La Ti Mn RGB Image D. A. Muller et al., Science, 2008.
55 Comparison of EELS and EDS EELS Atomic composition Chemical bonding Electronic properties Surface properties. Spatial resolution: nm EDS Atomic composition only Spatial resolution: 1 nm 10 nm Energy resolution: ~ 1 ev Energy resolution: ~ 130 ev (Mn K α ) Relatively difficult to use The interpretation sometimes involves theoretical calculation High collection efficiency (close to 100 %) Sensitive to lighter elements Signal weak in high loss region Easy to use The interpretation is straightforward Low collection efficiency (1-3%) (tilting helps to some degree) Sensitive to heavier elements Low yield for light elements
56 Energy Filtered Transmission Electron Microscopy Forming images with electrons of selected energy loss 1. Unfiltered image or diffraction pattern (DP) is formed 2. Image or DP is transformed into the spectrum 3. Part of the spectrum is selected by energy-selecting slit 4. Selected part of spectrum is transformed back into an energy-filtered image or DP Gatan: Review of EFTEM Fundamentals
57 Energy Filtered Transmission Electron Microscopy Spectrum imaging Spectrum imaging ZLP imaging Plasmon imaging ZLP Edges Edge imaging Low-loss Ti O Mn La x Image at DE1 Image at DE2 Image at DE3 Image at DEn y DE e- x 10^3 EFTEM Spectrum Imaging: Energy filtered broad beam technique Fills data cube taking one image at each energy at a time Less time STEM Spectrum Imaging Focused probe method Fills data cube by taking one spectrum at each location at a time Less does
58 EFTEM Zero-loss Peak imaging Spectrum imaging ZLP Low-loss Unstained/osmicated cebellar cortex Elastic electrons only Inelastic fog removed CBED Pattern Contrast enhanced (Good for medium thick samples) For Z < 12, the inelastic cross-section is larger than elastic cross-section Images from Gatan Review of EFTEM Fundamentals
59 EFTEM Plasmon Peak imaging EFTEM Plasmon Peak imaging Spectrum imaging Spectrum image (20 images) Al mapping image W mapping image A B Al W 30 nm A B J.G. Wen
60 EFTEM Edge Peak imaging Pre-edge image Post-edge image Image Ti Three-window Jump Ratio Imaging method Ti EELS spectrum Si Three Window Mapping Jump ratio J.G. Wen
61 EFTEM Edge Peak imaging Gatan: Review of EFTEM Fundamentals
62 List of TEMs and Functions at UIUC 1. JEOL JEM 2010 LaB6 TEM TEM, low dose, NBD, HRTEM, in-situ experiments 2. JEOL JEM 2100 LaB6 (Cryo-TEM) TEM, Low dose, special cryo-shielding 3. JEOL JEM 2010 F Analytical (S)TEM TEM, BF, DF, NAED, CBED, EDS, STEM, EELS, EFTEM 4. JEOL JEM 2200 FS C s corrected (S)TEM Ultra high resolution Z-contrast STEM, BF STEM, NBD, CBED, EDS, EELS, EFTEM 5. Hitachi H-9500 TEM In-situ heating and gas reaction, HREM, NAED, 300 kv, LaB6 electron source Gatan K2 camera for fast recording at 400 frames per second or 1600 frames per second using partial frame. 6. Hitachi H-600 TEM, 100 kv For biological applications, staff-assisted only. JEOL 2010 LaB6 JEOL 2200FS Heating stage (up to 1000 C) Cooling stage (with liquid N 2 ) JEOL 2100 Cryo Hitachi H-9500 JEOL 2010F
63 Thanks to our Platinum Sponsors: Thanks to our sponsors:
Transmission Electron Microscopy
Transmission Electron Microscopy Wacek Swiech, CQ Chen, Jim Mabon, Honghui Zhou and Matt Bresin Frederick Seitz Materials Research Laboratory University of Illinois at Urbana-Champaign Outline 1. Introduction
Scanning Electron Microscopy: an overview on application and perspective
Scanning Electron Microscopy: an overview on application and perspective Elvio Carlino Center for Electron Microscopy - IOM-CNR Laboratorio Nazionale TASC - Trieste, Italy Location of the Center for Electron
Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts
Electron Microscopy 3. SEM Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts 3-1 SEM is easy! Just focus and shoot "Photo"!!! Please comment this picture... Any
Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture
Nanoelectronics 09 Atsufumi Hirohata Department of Electronics 12:00 Wednesday, 4/February/2015 (P/L 006) Quick Review over the Last Lecture ( Field effect transistor (FET) ): ( Drain ) current increases
Looking through the fish-eye the Electron Ronchigram. Duncan T.L. Alexander CIME seminar May 24, 2012
Looking through the fish-eye the Electron Ronchigram Duncan T.L. Alexander CIME seminar May 24, 2012 Introduction Aim of the seminar: open a discussion on the Electron Ronchigram How is it formed? What
Physics 441/2: Transmission Electron Microscope
Physics 441/2: Transmission Electron Microscope Introduction In this experiment we will explore the use of transmission electron microscopy (TEM) to take us into the world of ultrasmall structures. This
Electron Microscopy SEM and TEM
Electron Microscopy SEM and TEM Content 1. Introduction: Motivation for electron microscopy 2. Interaction with matter 3. SEM: Scanning Electron Microscopy 3.1 Functional Principle 3.2 Examples 3.3 EDX
Chapter 14 High Resolution TEM
Chapter 14 High Resolution TEM K. Ishizuka (1980) Contrast Transfer of Crystal Images in TEM, Ultramicroscopy 5,pages 55-65. L. Reimer (1993) Transmission Electron Microscopy, Springer Verlag, Berlin.
View of ΣIGMA TM (Ref. 1)
Overview of the FESEM system 1. Electron optical column 2. Specimen chamber 3. EDS detector [Electron Dispersive Spectroscopy] 4. Monitors 5. BSD (Back scatter detector) 6. Personal Computer 7. ON/STANDBY/OFF
Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope
[email protected] Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope Bin Ming, András E. Vladár and Michael T. Postek National Institute of Standards and Technology
Preface Light Microscopy X-ray Diffraction Methods
Preface xi 1 Light Microscopy 1 1.1 Optical Principles 1 1.1.1 Image Formation 1 1.1.2 Resolution 3 1.1.3 Depth of Field 5 1.1.4 Aberrations 6 1.2 Instrumentation 8 1.2.1 Illumination System 9 1.2.2 Objective
7. advanced SEM. Latest generation of SEM SEM
7. advanced SEM SEM Low voltage SE imaging Condition of the surface, coatings, plasma cleaning Low voltage BSE imaging Polishing for BSE, EDX and EBSD, effect of ion beam etching/polishing 1 Latest generation
Properties of Electrons, their Interactions with Matter and Applications in Electron Microscopy
Properties of Electrons, their Interactions with Matter and Applications in Electron Microscopy By Frank Krumeich Laboratory of Inorganic Chemistry, ETH Zurich, Vladimir-Prelog-Weg 1, 8093 Zurich, Switzerland
Ion Beam Sputtering: Practical Applications to Electron Microscopy
Ion Beam Sputtering: Practical Applications to Electron Microscopy Applications Laboratory Report Introduction Electron microscope specimens, both scanning (SEM) and transmission (TEM), often require a
Lenses and Apertures of A TEM
Instructor: Dr. C.Wang EMA 6518 Course Presentation Lenses and Apertures of A TEM Group Member: Anup Kr. Keshri Srikanth Korla Sushma Amruthaluri Venkata Pasumarthi Xudong Chen Outline Electron Optics
Reflection Electron Microscopy and Spectroscopy for Surface Analysis
Reflection Electron Microscopy and Spectroscopy for Surface Analysis by Zhong Lin Wang 1 Introduction In 1986, E. Ruska was awarded the Nobel Physics Prize for his pioneering work of building the world's
EDS system. CRF Oxford Instruments INCA CRF EDAX Genesis EVEX- NanoAnalysis Table top system
EDS system Most common X-Ray measurement system in the SEM lab. Major elements (10 wt% or greater) identified in ~10 secs. Minor elements identifiable in ~100 secs. Rapid qualitative and accurate quantitative
Polarization Dependence in X-ray Spectroscopy and Scattering. S P Collins et al Diamond Light Source UK
Polarization Dependence in X-ray Spectroscopy and Scattering S P Collins et al Diamond Light Source UK Overview of talk 1. Experimental techniques at Diamond: why we care about x-ray polarization 2. How
CSCI 4974 / 6974 Hardware Reverse Engineering. Lecture 8: Microscopy and Imaging
CSCI 4974 / 6974 Hardware Reverse Engineering Lecture 8: Microscopy and Imaging Data Acquisition for RE Microscopy Imaging Registration and stitching Microscopy Optical Electron Scanning Transmission Scanning
The Basics of Scanning Electron Microscopy
The Basics of Scanning Electron Microscopy The small scanning electron microscope is easy to use because almost every variable is pre-set: the acceleration voltage is always 15kV, it has only a single
Introduction to microstructure
Introduction to microstructure 1.1 What is microstructure? When describing the structure of a material, we make a clear distinction between its crystal structure and its microstructure. The term crystal
Principles & Practice of Electron Diffraction
Principles & Practice of Electron Diffraction Duncan Alexander EPFL-CIME 1 Contents Introduction to electron diffraction Elastic scattering theory Basic crystallography & symmetry Electron diffraction
Phase Characterization of TiO 2 Powder by XRD and TEM
Kasetsart J. (Nat. Sci.) 42 : 357-361 (28) Phase Characterization of TiO 2 Powder by XRD and TEM Kheamrutai Thamaphat 1 *, Pichet Limsuwan 1 and Boonlaer Ngotawornchai 2 ABSTRACT In this study, the commercial
Introduction to EELS
Introduction to EELS Nestor J. Zaluzec [email protected] [email protected] Brief Review of Energy Loss Processes Instrumentation: Detector Systems Instrumentation: AEM Systems Data Analysis
Scanning Electron Microscopy tools for material characterization
5th International Workshop on Mechanisms of Vacuum Arcs 02-04/09/2015 Scanning Electron Microscopy tools for material characterization Focus on EBSD for characterisation of dislocation structures Floriane
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light Name: Period: Date: MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) Reflection,
Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications
Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications Saulius Marcinkevičius Optics, ICT, KTH 1 Outline Optical near field. Principle of scanning near field optical microscope
6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?
Test IV Name 1) In a single slit diffraction experiment, the width of the slit is 3.1 10-5 m and the distance from the slit to the screen is 2.2 m. If the beam of light of wavelength 600 nm passes through
Microscopic Techniques
Microscopic Techniques Outline 1. Optical microscopy Conventional light microscopy, Fluorescence microscopy, confocal/multiphoton microscopy and Stimulated emission depletion microscopy 2. Scanning probe
X-ray diffraction techniques for thin films
X-ray diffraction techniques for thin films Rigaku Corporation Application Laboratory Takayuki Konya 1 Today s contents (PM) Introduction X-ray diffraction method Out-of-Plane In-Plane Pole figure Reciprocal
5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy
5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy Resolution of optical microscope is limited by diffraction. Light going through an aperture makes diffraction
Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University
Chapter 4 Microscopy, Staining, and Classification 2012 Pearson Education Inc. Lecture prepared by Mindy Miller-Kittrell North Carolina State University Microscopy and Staining 2012 Pearson Education Inc.
Electron Microprobe Analysis X-ray spectrometry:
Electron Microprobe Analysis X-ray spectrometry: 1. X-ray generation and emission 2. X-ray detection and measurement X-ray energy and wavelength E=hν h : Planck's constant (6.626x10-34 Joule.sec or, 6.626x10-34
Tecnai on-line help Working with a FEG 1 FEG_A4.doc Software version 2
Tecnai on-line help Working with a FEG 1 Tecnai on-line help manual -- Working with a FEG Table of Contents 1 Introduction...2 2 FEG Safety...2 2.1 The column valves...2 3 FEG States...3 4 Starting the
h e l p s y o u C O N T R O L
contamination analysis for compound semiconductors ANALYTICAL SERVICES B u r i e d d e f e c t s, E v a n s A n a l y t i c a l g r o u p h e l p s y o u C O N T R O L C O N T A M I N A T I O N Contamination
Scanning Electron Microscopy Primer
Scanning Electron Microscopy Primer Bob Hafner This primer is intended as background for the Introductory Scanning Electron Microscopy training offered by the University of Minnesota s Characterization
EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab
EXPERIMENT O-6 Michelson Interferometer Abstract A Michelson interferometer, constructed by the student, is used to measure the wavelength of He-Ne laser light and the index of refraction of a flat transparent
Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts
Electron Microscopy 3. SEM Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts SEM is easy! Just focus and shoot "Photo"!!! Please comment this picture... Any idea
Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.
Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM. Some limitations (disadvantages) of NSOM A trade-off
Near-field scanning optical microscopy (SNOM)
Adviser: dr. Maja Remškar Institut Jožef Stefan January 2010 1 2 3 4 5 6 Fluorescence Raman and surface enhanced Raman 7 Conventional optical microscopy-limited resolution Two broad classes of techniques
Lateral Resolution of EDX Analysis with Low Acceleration Voltage SEM
Original Paper Lateral Resolution of EDX Analysis with Low Acceleration Voltage SEM Satoshi Hashimoto 1, Tsuguo Sakurada 1, and Minoru Suzuki 2 1 JFE-Techno research corporation, 1-1 Minamiwatarida, Kawasaki,
Acoustic GHz-Microscopy: Potential, Challenges and Applications
Acoustic GHz-Microscopy: Potential, Challenges and Applications A Joint Development of PVA TePLa Analytical Systems GmbH and Fraunhofer IWM-Halle Dr. Sebastian Brand (Ph.D.) Fraunhofer CAM Fraunhofer Institute
CREOL, College of Optics & Photonics, University of Central Florida
OSE6650 - Optical Properties of Nanostructured Materials Optical Properties of Nanostructured Materials Fall 2013 Class 3 slide 1 Challenge: excite and detect the near field Thus far: Nanostructured materials
Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES
BIODIVERSITY I BIOL1051 Microscopy Professor Marc C. Lavoie [email protected] MAJOR FUNCTIONS OF MICROSCOPES MAGNIFY RESOLVE: => INCREASE CONTRAST Microscopy 1. Eyepieces 2. Diopter adjustment
Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red
Changing the economics of space Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red J. Fernandez-Saldivar 1, F. Culfaz 1,
Defects Introduction. Bonding + Structure + Defects. Properties
Defects Introduction Bonding + Structure + Defects Properties The processing determines the defects Composition Bonding type Structure of Crystalline Processing factors Defects Microstructure Types of
WAVELENGTH OF LIGHT - DIFFRACTION GRATING
PURPOSE In this experiment we will use the diffraction grating and the spectrometer to measure wavelengths in the mercury spectrum. THEORY A diffraction grating is essentially a series of parallel equidistant
DOE Solar Energy Technologies Program Peer Review. Denver, Colorado April 17-19, 2007
DOE Solar Energy Technologies Program Peer Review Evaluation of Nanocrystalline Silicon Thin Film by Near-Field Scanning Optical Microscopy AAT-2-31605-05 Magnus Wagener and George Rozgonyi North Carolina
X-ray Diffraction and EBSD
X-ray Diffraction and EBSD Jonathan Cowen Swagelok Center for the Surface Analysis of Materials Case School of Engineering Case Western Reserve University October 27, 2014 Outline X-ray Diffraction (XRD)
Introduction to Optics
Second Edition Introduction to Optics FRANK L. PEDROTTI, S.J. Marquette University Milwaukee, Wisconsin Vatican Radio, Rome LENO S. PEDROTTI Center for Occupational Research and Development Waco, Texas
DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND
DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND THE THREE-DIMENSIONAL DISTRIBUTION OF THE RADIANT FLUX DENSITY AT THE FOCUS OF A CONVERGENCE BEAM
Secondary Ion Mass Spectrometry
Secondary Ion Mass Spectrometry A PRACTICAL HANDBOOK FOR DEPTH PROFILING AND BULK IMPURITY ANALYSIS R. G. Wilson Hughes Research Laboratories Malibu, California F. A. Stevie AT&T Bell Laboratories Allentown,
Introduction to Powder X-Ray Diffraction History Basic Principles
Introduction to Powder X-Ray Diffraction History Basic Principles Folie.1 History: Wilhelm Conrad Röntgen Wilhelm Conrad Röntgen discovered 1895 the X-rays. 1901 he was honoured by the Noble prize for
Coating Thickness and Composition Analysis by Micro-EDXRF
Application Note: XRF Coating Thickness and Composition Analysis by Micro-EDXRF www.edax.com Coating Thickness and Composition Analysis by Micro-EDXRF Introduction: The use of coatings in the modern manufacturing
Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014
Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014 Introduction Following our previous lab exercises, you now have the skills and understanding to control
Diffraction of a Circular Aperture
Diffraction of a Circular Aperture Diffraction can be understood by considering the wave nature of light. Huygen's principle, illustrated in the image below, states that each point on a propagating wavefront
Introduction to X-Ray Powder Diffraction Data Analysis
Introduction to X-Ray Powder Diffraction Data Analysis Center for Materials Science and Engineering at MIT http://prism.mit.edu/xray An X-ray diffraction pattern is a plot of the intensity of X-rays scattered
Usage of AFM, SEM and TEM for the research of carbon nanotubes
Usage of AFM, SEM and TEM for the research of carbon nanotubes K.Safarova *1, A.Dvorak 2, R. Kubinek 1, M.Vujtek 1, A. Rek 3 1 Department of Experimental Physics, Faculty of Science, Palacky University,
Acousto-optic modulator
1 of 3 Acousto-optic modulator F An acousto-optic modulator (AOM), also called a Bragg cell, uses the acousto-optic effect to diffract and shift the frequency of light using sound waves (usually at radio-frequency).
Geometric Optics Converging Lenses and Mirrors Physics Lab IV
Objective Geometric Optics Converging Lenses and Mirrors Physics Lab IV In this set of lab exercises, the basic properties geometric optics concerning converging lenses and mirrors will be explored. The
Status of the FERMI@Elettra Free Electron Laser
Status of the FERMI@Elettra Free Electron Laser E. Allaria on behalf of the FERMI team Work partially supported by the Italian Ministry of University and Research under grants FIRB-RBAP045JF2 and FIRB-RBAP06AWK3
Diffraction Course Series 2015
Diffraction Course Series 2015 Mark Wainwright Analytical Centre Kensington Campus, Chemical Sciences Building F10, Room G37 The Mark Wainwright Analytical Centre is offering a new series of courses covering
Automatic and Objective Measurement of Residual Stress and Cord in Glass
Automatic and Objective Measurement of Residual Stress and Cord in Glass GlassTrend - ICG TC15/21 Seminar SENSORS AND PROCESS CONTROL 13-14 October 2015, Eindhoven Henning Katte, ilis gmbh copyright ilis
Measuring the Point Spread Function of a Fluorescence Microscope
Frederick National Laboratory Measuring the Point Spread Function of a Fluorescence Microscope Stephen J Lockett, PhD Principal Scientist, Optical Microscopy and Analysis Laboratory Frederick National
Detailed Alignment Procedure for the JEOL 2010F Transmission Electron Microscope
Detailed Alignment Procedure for the JEOL 2010F Transmission Electron Microscope by Wendy Sarney ARL-MR-603 December 2004 Approved for public release; distribution unlimited. NOTICES Disclaimers The findings
It has long been a goal to achieve higher spatial resolution in optical imaging and
Nano-optical Imaging using Scattering Scanning Near-field Optical Microscopy Fehmi Yasin, Advisor: Dr. Markus Raschke, Post-doc: Dr. Gregory Andreev, Graduate Student: Benjamin Pollard Department of Physics,
for Low power Energy Harvesting Sun to fiber' Solar Devices
Nanostructured Energy Conversion for Low power Energy Harvesting Devices and Beyond for High power Sun to fiber' Solar Devices Michael Oye and Nobuhiko Nobby Kobayashi Advanced Studies Laboratories and
Vacuum Evaporation Recap
Sputtering Vacuum Evaporation Recap Use high temperatures at high vacuum to evaporate (eject) atoms or molecules off a material surface. Use ballistic flow to transport them to a substrate and deposit.
ORIENTATION CHARACTERISTICS OF THE MICROSTRUCTURE OF MATERIALS
ORIENTATION CHARACTERISTICS OF THE MICROSTRUCTURE OF MATERIALS K. Sztwiertnia Polish Academy of Sciences, Institute of Metallurgy and Materials Science, 25 Reymonta St., 30-059 Krakow, Poland MMN 2009
Spectroscopic Ellipsometry:
Spectroscopic : What it is, what it will do, and what it won t do by Harland G. Tompkins Introduction Fundamentals Anatomy of an ellipsometric spectrum Analysis of an ellipsometric spectrum What you can
Types of Epitaxy. Homoepitaxy. Heteroepitaxy
Epitaxy Epitaxial Growth Epitaxy means the growth of a single crystal film on top of a crystalline substrate. For most thin film applications (hard and soft coatings, optical coatings, protective coatings)
Introduction to EDX. Energy Dispersive X-ray Microanalysis (EDS, Energy dispersive Spectroscopy) Basics of EDX
Introduction to EDX Energy Dispersive X-ray Microanalysis (EDS, Energy dispersive Spectroscopy) EDX Marco Cantoni 1 Basics of EDX a) Generation of X-rays b) Detection Si(Li) Detector, SDD Detector, EDS
waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object
PHYS1000 Optics 1 Optics Light and its interaction with lenses and mirrors. We assume that we can ignore the wave properties of light. waves rays We represent the light as rays, and ignore diffraction.
Supporting Information
Supporting Information Simple and Rapid Synthesis of Ultrathin Gold Nanowires, Their Self-Assembly and Application in Surface-Enhanced Raman Scattering Huajun Feng, a Yanmei Yang, a Yumeng You, b Gongping
Vincent FAVRE-NICOLIN Univ. Grenoble Alpes & CEA Grenoble/INAC/SP2M XDISPE (ANR JCJC SIMI10 2011)
Vincent FAVRE-NICOLIN Univ. Grenoble Alpes & CEA Grenoble/INAC/SP2M XDISPE (ANR JCJC SIMI10 2011) Imagerie par diffraction des rayons X de nano-objets uniques pour la photonique et l'électronique X-ray
Time out states and transitions
Time out states and transitions Spectroscopy transitions between energy states of a molecule excited by absorption or emission of a photon hn = DE = E i - E f Energy levels due to interactions between
X-ray thin-film measurement techniques
Technical articles X-ray thin-film measurement techniques II. Out-of-plane diffraction measurements Toru Mitsunaga* 1. Introduction A thin-film sample is two-dimensionally formed on the surface of a substrate,
PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. III - Surface Characterization - Marie-Geneviève Barthés-Labrousse
SURFACE CHARACTERIZATION Marie-Geneviève Centre d Etudes de Chimie Métallurgique, CNRS, Vitry-sur-Seine, France Keywords: Surface Analysis, Surface imaging, Surface composition, Surface chemical analysis,
Scanning Near-Field Optical Microscopy for Measuring Materials Properties at the Nanoscale
Scanning Near-Field Optical Microscopy for Measuring Materials Properties at the Nanoscale Outline Background Research Design Detection of Near-Field Signal Submonolayer Chemical Sensitivity Conclusions
Crystal Optics of Visible Light
Crystal Optics of Visible Light This can be a very helpful aspect of minerals in understanding the petrographic history of a rock. The manner by which light is transferred through a mineral is a means
Image Formation in the Electron Microscope
T H E U N I V E R S I T Y of T E X A S S C H O O L O F H E A L T H I N F O R M A T I O N S C I E N C E S A T H O U S T O N Image Formation in the Electron Microscope For students of HI 6001-125 Computational
Raman spectroscopy Lecture
Raman spectroscopy Lecture Licentiate course in measurement science and technology Spring 2008 10.04.2008 Antti Kivioja Contents - Introduction - What is Raman spectroscopy? - The theory of Raman spectroscopy
How To Understand Light And Color
PRACTICE EXAM IV P202 SPRING 2004 1. In two separate double slit experiments, an interference pattern is observed on a screen. In the first experiment, violet light (λ = 754 nm) is used and a second-order
Scanning He + Ion Beam Microscopy and Metrology. David C Joy University of Tennessee, and Oak Ridge National Laboratory
Scanning He + Ion Beam Microscopy and Metrology David C Joy University of Tennessee, and Oak Ridge National Laboratory The CD-SEM For thirty years the CD-SEM has been the tool for metrology But now, as
Laue lens for Nuclear Medicine
Laue lens for Nuclear Medicine PhD in Physics Gianfranco Paternò Ferrara, 6-11-013 Supervisor: prof. Vincenzo Guidi Sensors and Semiconductors Lab, Department of Physics and Earth Science, University of
Introduktion til røntgenfluorescens (XRF) og skanning elektron mikroskopi (SEM) Michelle Taube Nationalmuseet Bevaringsafdelingen
Introduktion til røntgenfluorescens (XRF) og skanning elektron mikroskopi (SEM) Michelle Taube Nationalmuseet Bevaringsafdelingen Introduktion til røntgenfluorescens (XRF) og skanning elektron mikroskopi
Interference. Physics 102 Workshop #3. General Instructions
Interference Physics 102 Workshop #3 Name: Lab Partner(s): Instructor: Time of Workshop: General Instructions Workshop exercises are to be carried out in groups of three. One report per group is due by
Rodenstock Photo Optics
Rogonar Rogonar-S Rodagon Apo-Rodagon N Rodagon-WA Apo-Rodagon-D Accessories: Modular-Focus Lenses for Enlarging, CCD Photos and Video To reproduce analog photographs as pictures on paper requires two
Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)
Low energy ion scattering study of 4 on Cu(1) Chapter 8. Low energy ion scattering study of 4 on Cu(1) 8.1. Introduction For a better understanding of the reconstructed 4 surfaces one would like to know
A Guide to Acousto-Optic Modulators
A Guide to Acousto-Optic Modulators D. J. McCarron December 7, 2007 1 Introduction Acousto-optic modulators (AOMs) are useful devices which allow the frequency, intensity and direction of a laser beam
Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.
Revision problem Chapter 18 problem 37 page 612 Suppose you point a pinhole camera at a 15m tall tree that is 75m away. 1 Optical Instruments Thin lens equation Refractive power Cameras The human eye Combining
NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY WITH STM AND AFM PROBES
Vol. 93 (1997) A CTA PHYSICA POLONICA A No. 2 Proceedings of the 1st International Symposium on Scanning Probe Spectroscopy and Related Methods, Poznań 1997 NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY
First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between
Optical Differences Between Telescopes and Microscopes Robert R. Pavlis, Girard, Kansas USA icroscopes and telescopes are optical instruments that are designed to permit observation of objects and details
How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer
What is ICP-MS? and more importantly, what can it do? Inductively Coupled Plasma Mass Spectrometry or ICP-MS is an analytical technique used for elemental determinations. The technique was commercially
Solid State Detectors = Semi-Conductor based Detectors
Solid State Detectors = Semi-Conductor based Detectors Materials and their properties Energy bands and electronic structure Charge transport and conductivity Boundaries: the p-n junction Charge collection
Lectures about XRF (X-Ray Fluorescence)
1 / 38 Lectures about XRF (X-Ray Fluorescence) Advanced Physics Laboratory Laurea Magistrale in Fisica year 2013 - Camerino 2 / 38 X-ray Fluorescence XRF is an acronym for X-Ray Fluorescence. The XRF technique
Basic principles and mechanisms of NSOM; Different scanning modes and systems of NSOM; General applications and advantages of NSOM.
Lecture 16: Near-field Scanning Optical Microscopy (NSOM) Background of NSOM; Basic principles and mechanisms of NSOM; Basic components of a NSOM; Different scanning modes and systems of NSOM; General
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS 1. Photons 2. Photoelectric Effect 3. Experimental Set-up to study Photoelectric Effect 4. Effect of Intensity, Frequency, Potential on P.E.