Common parts for OGS/OVS/OTS/OPS 2.X/xx

Size: px
Start display at page:

Download "Common parts for OGS/OVS/OTS/OPS 2.X/xx"

Transcription

1 Common parts for OGS/OVS/OTS/OPS 2.X/xx Part no Description Electronic cabinets Alarm unit AU2.1 PCB Alarm unit AU2.0 PCB (This is the former version) Switch Master PCB Power Puls 3A 72W, replacement for earlier powers Power Puls 4,2A 100W, replacement for earlier powers Impulse push button Toggle Push Button Buzzer Contact element 2 NO Contact element 2 NO/1NC Countersunk module for panel 24*24mm (sort) Countersunk module for panel 24*30mm (sort) Countersunk module for panel 24*24mm (sort) w. protection cover Switch cap red Switch cap blå Switch cap green Blind cover 24x Bulb for switch Relay 24VDC 1-pole, Omron Relaysocket 1-pole, Omron Relay 24VDC 2 pole, Omron Relaysocket 2-pole, Omron Relay 24v 1-pole, PLC-BSP 24DC/21AU, complete Relay 24VDC, 1pole for sensor powering, complete Relay 24v 2-pole, PLC-RSP-24DC/21, complete Single terminal Double terminal Ex Z.Barrier Z-787-H P&F (4-20mA) Galvanic Isolator, KFD2-CD Zener Barriere KFD2-CR-EX1(95145) Isolated repeater KFD2-STC4-Ex Isolated repeater 2-channel, Analog, D1010D Isolated repeater 1-channel, Analog, D1010S Isolated repeater 2-channel, Analog, D1014D Isolated repeater 2-channel, Analog, D1014D.B "Bus powering" Isolated repeater 1-channel, Analog, D1014S Isolated repeater 2-channel, Digital Inn, D1030D Isolated repeater 1-channel, Digital Inn, D1030S Isolated repeater 4-channel, Digital Inn, D1032Q Galvanic barrier, 4-channel Dig. Out D1043Q Door stopper for Rittal cabinets, 1 complete kit Door stopper for Eldon cabinets

2 Detector Cabinet For OGA systems Power Puls 3A 72W, replacement for earlier powers Power Puls 4,2A 100W, replacement for earlier powers HC sensor for OGA system HC sensor for OGA in cabinet O2 sensor for OGA H2S sensor for OGA Flow sensor 0-60l/h for OGA Omicron Propane sensor complete for OGA Omicron SO2 sensor for OGA Flow sensor 0-360l/h for OGA Flow sensor cell 0-60 L/H for OGA Hoseclip for OGA sensors /4" Inch male union O2 sensor KE-50 for OGA Hc sensor/p300 for OGA H2S sensor/7hh-lm for OGA Sample pump 115/230VAC N Sample Pump 115/230VAC N Rep Kit for vacuum pump N5/N3

3 Detector Cabinet For Vapour systems Way valve B 1/8"Female NPT Way valve B 1/8"Female NPT (1 in, 2 out) For special only Way valve B 1/8"Female NPT Way valve B 1/8"Female NPT 7-Way valve B 1/8"OD For special only B Quickconn male 6mmOD open/open B Quickconn female 6mmOD open/open SS Female bulkh. 1/4"NPTx6mmOD SS Male connector 1/4"NPTX10mmOD SS Male conn. 1/4"NPTX8mmOD(Tess) Flowmeter l/h Flow Alarm Initiator, RC Crowcon Xgard Oxygen (0-25%) Type 1, Replaces TxGard IS Crowcon Xgard Oxygen refill sensor O2 refill sensor (i kjøleskap)(s01-169) For TxGard IS Pressure transducer 4tech 0 -> 200mbar Pressure transducer 4tech > 250mbar Various Sensors used in 2.X/XX systems Various sensors in the OPUS family OPUS HC sensor 0-100% L.E.L., Complete OPUS H2S sensor 0-50ppm, Complete OPUS O2 sensor 0-25% Vol., Complete OPUS sensor for el. chem. Cartridge, 2110B OPUS Transmitter 4-20mA W/Sensor, 2110B OPUS Plug-in cartridge for CH4 Methane, LEL, 2110B OPUS Plug-in cartridge for H2S 0-50ppm, 2110B OPUS Plug-in cartridge for N-Buthane, LEL, 2110B OPUS Plug-in cartridge for O2, 0-21%V/V, 2110B OPUS Plug-in cartridge for Ammonia, 0-50ppm, 2110B OPUS/APEX weather protection, 2110B OPUS lock ring, 2110B OPUS Duct adapter (Non-Ex), 2110B Flowhousing for OPUS and APEX, 2110B2140 Transmitter--> Sensor --> Cartridge--> Lock ring-->

4 Various sensors in the APEX family APEX HC sensor 0-100%L.E.L. complete, 2110N APEX H2S sensor 0-50 P.P.M. complete APEX Transmitter ATEX Certified 2 x M25, 2110B APEX Transmitter unit fixture kit, 2110B APEX Transmitter unit Interconnect PCB, 2110B APEX Transmitter unit LCD module 2110B APEX Transmitter unit lid O-ring, 2110B APEX Transmitter unit Main board assembly, 2110B APEX Transmitter Ribbon cable, 2110B APEX Certified sensor, 2110B APEX Plug-In Cartridge O2 21%, 2110B APEX Plug-In Cartridge Methane 0-100%LEL, 2110B APEX Plug-In Cartridge H2S 0-50ppm, 2110B APEX Plug-In Cartridge N-butan 0-100%LEL, 2110B APEX Plug-In Cartridge CO, 0-500ppm, 2110B APEX Oxygen Transducer adapter, 2110B APEX Black cage for cartridge APEX Carbon filter, 2110B APEX Mesh filter, 2110B APEX Hydrophobic filter, 2110B APEX Duct mounting kit SS316L, A APEX Test cap for Duct mounting kit APEX Sunshade, 2110B APEX OPUS/APEX weather protection, 2110B APEX Flowhousing for OPUS and APEX, 2110B2140 Transmitter--> Sensor--> Cartridge--> Lock ring-->

5 Various sensors in the OPTIMA family Optima Plus IR Optima Pluss 0-100% L.E.L., 2108N Optima Plus W/Hawke (PL612) connection box Optima Plus IR Optima Pluss w/flowcap Optima Plus 0-100% LEL / weather protection Optima Plus 0-100%Vol Methane Optima Plus IR sensor duct mounting Optima Plus Plastic Nuts for flow housing Optima Plus Dust cover/barrier Optima Plus Sunshade/deluge protection Optima Plus Remote gassing cell Optima Plus, Flowhousing, 2108D Optima Plus, Optima Plus Gassing cover, 2108D Optima Plus, Weather protection, 2108D Optima Plus, Optima Plus Duct mounting kit, A Optima Plus, Calibration Unit for Optima IR, Interigator " Be aware that if you have the old type OPTIMA, that you mention this in the event of an enquiry so that you get the correct parts supplied. Easiest way to check this is to take a look at the sticker on your OPTIMA, if this is red you have the older version. If this sticker is not visible, turn the metal strap (*) on the sensor until you can read which sensor you need parts for. " * Please see below picture, the sticker is at the "end" of the sensor and the metal strap is almost in the centre of the sensor.

6 Various sensors in the SENSEPOINT family Sensepoint HC 0-100% LEL, 2106B Sensepoint O2 sensor 0-25%, 2106B Sensepoint H2S sensor 0-50%ppm, 2106B Sensepoint H2S cell exchange kit, 2106B Sensepoint O2 cell exchange kit, 2106B Sensepoint Reducer M25-M20, SS316, RDU Sensepoint Filter housing/retainer Sensepoint Weather protection (Combustible), A Sensepoint Catalytic bridge 4-20mAm 2414N Sensepoint Flowhousing, 02000A Sensepoint Weather housing, 02000A Sensepoint Calibration kit(toxic/o2) 2106B Sensepoint, Gas Calibration cap, 2106D2097 Combustible Toxic & Oxygen Sensepoint Plus HC 0-100%LEL Sensepoint Plus O2 0-25%VOL Sensepoint Plus H2S 0-50ppm Sensepoint HC Pro/Plus spare sensor Sensepoint O2 Pro/Plus Spare sensor Sensepoint H2S Pro/Plus spare sensor Sensepoint Pro/Plus Duct mounting kit Sensepoint Plus (Zareba) Sensepoint PRO HC 0-100%LEL Metane Sensepoint PRO 0-25%VOL O Sensepoint PRO 0-50ppm H2S Sensepoint HC Pro/Plus spare sensor Sensepoint O2 Pro/Plus Spare sensor Sensepoint H2S Pro/Plus spare sensor Sensepoint Pro/Plus Duct mounting kit Sensepoint PRO (Zareba Plus)

7 Pressure sensor Pressure sensor 4tech 0-200mbar Pressure sensor 4tech -100 to 250mbar Pressure sensor 4tech 0-200mbar Mount. in box Pressure sensor 4tech -100 to 250mbar Mount. in box Pressure sensor 4tech -100 to 600 mbar Typical pressure sensor These are also mounted in boxes, or with brackets inside cabinets (e.g. vapour). Different sensors from Crowcon O2 sensor TxGard (Discont.) O2 sensor head refill for TxGard H2S sensor TxGard Complete (Discont.) H2S Sensor Head refill H2S sensor TXgard IS O2 sensor Txgard IS O2 sensor Xgard O2 sensor head refill for Xgard H2S Sensor XGard H2S Sensor Head refill for Xgard HC sensor flamgard Amplifier FlamGard Plus Terminal Board FlamGard Plus HC sensor Flamgard Pluss w/display HC sensor head refill, for FlamGard+, and GasLink Examples shown below Xgard FlamGard+ TxGard IS+ Replaces the former Replaces the former Various TxGard IS GasLink applications

8 Temperature Sensors (PT 100) Temperature sensor W-GYK Temperature sensor W-SOK PT 100 Housing MH-M , specify length Transmitter Ex PT100, 4-20 ma (PR5333)

EXPLORER 4 MULTIPOINT

EXPLORER 4 MULTIPOINT EXPLORER 4 MULTIPOINT Sampling gas analyser EXPLORER 4 MULTIPOINT is a sampling gas analyser, with 4 gas detection sensors ( LEL,H2S, O2 CO ) reliable and in accordance of the Rules with 15 sampling points

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject

More information

GROENEVELD AUTOMATIC GREASING SYSTEMS

GROENEVELD AUTOMATIC GREASING SYSTEMS GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991

More information

Sieger Searchpoint Optima Plus

Sieger Searchpoint Optima Plus Sieger Searchpoint Optima Plus Advanced infrared point gas detector Sieger Searchpoint Optima Plus Why Searchpoint Optima Plus is the right choice... The proven strengths of the original Searchpoint OPTIMA

More information

EX 2000/EX 2000 C/ GD 2000/GDP

EX 2000/EX 2000 C/ GD 2000/GDP Gas detectors EX 2000/EX 2000 C/ GD 2000/GDP 2000 Gas Discrimination (GD 2000 / GDP 2000) Explosimeters/ Catharometers Pocket size Long battery life High reliability New design for Enhanced performance

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

Buckeye Detection Systems Fixed Detection Systems Application Survey

Buckeye Detection Systems Fixed Detection Systems Application Survey Buckeye Detection Systems Fixed Detection Systems Application Survey Channel Partner Representative : Company Name: Representative: BDS Representative: Client Contact Information : Company Name: Company

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement. and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the

More information

Ultima X Series Gas Monitors

Ultima X Series Gas Monitors Ultima X Series Gas Monitors For continuous monitoring of oxygen, toxics, and combustible gases Now with SIL 2 Certified Products MSA s Ultima X Series Gas Monitors are microprocessor-based transmitters

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors Faster response higher accuracy greater stability longer life. Dräger electrochemical sensors offer all these benefits. The robust

More information

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI) FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous

More information

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000 IMR 5000 Continuous Flue Gas Monitoring System The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000

More information

GasAlertMax XT II H 2 O 2 LEL

GasAlertMax XT II H 2 O 2 LEL Simple operation with pump The rugged GasAlertMax XT II reliably monitors for up to four gas hazards and combines straightforward one-button field operation with an integrated sampling pump. Tamper-proof,

More information

CutMaster 82. 6.04 Major External Replacement Parts

CutMaster 82. 6.04 Major External Replacement Parts CutMaster 8 6.0 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-08 Tube, roll handle 9-0 Front Panel 9-07 Rear Panel 9-00 Art # A-080

More information

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons

More information

Engineering Specifications XNX Universal Transmitter

Engineering Specifications XNX Universal Transmitter Engineering Specifications XNX Universal Transmitter 1.0 General Description: The XNX Universal Transmitter is a comprehensive solution designed to operate in hazardous locations and utilize sensor technologies

More information

SECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

SECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS SECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS PART 1 - GENERAL 1.01 Section Includes A. Requirements for provision of the Natural Gas (CH4), Carbon Monoxide (CO)

More information

The L&J Engineering Model MCG 1500SFI Servo Gauge

The L&J Engineering Model MCG 1500SFI Servo Gauge PRODUCT DATA SHEET The is the most compact and lightest servo available today. Accuracy / repeatability of 1/32 inch (0.8mm) Product and Interface, custody transfer Wireless Infrared Calibration Advanced

More information

TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output 133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame

More information

Automation & Sanitization REPLACEMENT PARTS

Automation & Sanitization REPLACEMENT PARTS & Sanitization PROLOGIC GLX-PCB-PRO Main PCB, ProLogic GLX-PL-LOC-P-4 Display, Local, ProLogic, P-4 GLX-PL-LOC-PS4 Display, Local, ProLogic, PS-4 GLX-PL-LOC-PS8 Display, Local, ProLogic, PS-8 GLX-PL-LOC-PS16

More information

Application Requirement

Application Requirement Hazardous Gas Monitors Sensor Selection Overview Safety Monitoring (LEL) Toxic Limit Detection (PEL) Leak Detection Personal Safety Application Requirement Exposure Assessment (TWA) Ambient Air Quality

More information

RAEGuard EC FGM-13XX

RAEGuard EC FGM-13XX RAEGuard EC FGM-13XX User s Guide P/N 033-4102-000 Rev B May 2007 - READ BEFORE OPERATING - This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining,

More information

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES LDC-4000 COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES WWW.JBIND.COM 800.323.0811 [email protected] TABLE OF CONTENTS LDC-4000

More information

FANG 24T, 26T and 28T -EU

FANG 24T, 26T and 28T -EU Model: FANG 24T FANG 26T FANG 28T Lista Części Polish Spis Treści Solution tank 3 Recovery tank 5 Brush lift - Drive 7 Brush - Pad Drive 9 Solution Control 11 Brush skirt 13 Control housing 15 Squeegee

More information

ALTAIR 5X Multigas Detector Bid Specification

ALTAIR 5X Multigas Detector Bid Specification ALTAIR 5X Multigas Detector Bid Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Size, pumped unit with PID Weight Handling Case material Environmental

More information

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 Form No. 74-00-4001 S168-195-001 Revision E DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 INTRODUCTION Allied Healthcare Products, Inc. s Digital Alarm

More information

PortaSens ll G AS DETECTOR

PortaSens ll G AS DETECTOR PortaSens ll G AS DETECTOR ONE DETECTOR... FOR MANY GASES! Sensors can be exchanged quickly and easily without the need for calibration. Sensors are maintained in ready condition in the optional sensor

More information

Analytical Instruments Smart Analyzer 90 Type SMA

Analytical Instruments Smart Analyzer 90 Type SMA Data Sheet Analytical Instruments Smart Analyzer 90 Type SMA Oxygen Only or Optional Oxygen and Combustibles Rugged Industrial Design Easy Installation and Start-up Highly Accurate Sensors Simplified In-house

More information

RECON-4 Portable Multi-gas Detector Software Manual

RECON-4 Portable Multi-gas Detector Software Manual ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 www.enmet.com RECON-4 Portable Multi-gas Detector Software Manual Version:HW091211001 Manual Part Number 80006-034 January, 2011 Brief Introduction

More information

IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION

IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION Form No. 74-00-4001 S168-527-001 Rev. B IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION Allied Healthcare Products, Inc. s IMPACT alarms are designed

More information

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge! Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm

More information

The Ambient Air Monitoring System

The Ambient Air Monitoring System The Ambient Air Monitoring System 1.0 Introduction: The Ambient Air Monitoring System (AAMS) can measure a range of toxic and flammable gases, particulate matter, meteorological and environmental parameters

More information

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P 2 Alarm Levels Bargraph + LED Indication of Gas Concentration Visual and Audible Signalization of Activated Alarm Levels 2 SPDT 5A/250V Output Relays Shock-Proof

More information

Regulator Options and Accessories

Regulator Options and Accessories Regulator Options and Accessories Regulator accessories are available separately or mounted on Swagelok regulators. Some accessories limit regulator pressure or temperature ratings. Additional materials,

More information

O C M III. Open Channel Flow Monitor

O C M III. Open Channel Flow Monitor O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this

More information

CutMaster 102. 6.04 Major External Replacement Parts

CutMaster 102. 6.04 Major External Replacement Parts CutMaster 0 6.04 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-086 Tube, roll handle 9-0 4 Front Panel 9-087 Rear Panel 9-00 4 Art #

More information

Fire Alarm System Accessories

Fire Alarm System Accessories Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer

More information

ngenieros Ingenieros Asociados De Control S.L.

ngenieros Ingenieros Asociados De Control S.L. ngenieros sociados de ontrol 1 Company founded in 1985 to serve commercial and technical assistance in the fields of instrumentation, control and installation for all types of industries. We offer top

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461 D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex

More information

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE Table of Contents 1 Meridian Overview 2 Meridian Specifications 4 Supported Gases 5 Multi Sensor Configurations 6 Technical Drawings 16 Accessories

More information

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Before installation it is important to know what parts you have and what the capabilities of these parts are. INSTALLATION GUIDE Before installation it is important to know what parts you have and what the capabilities of these parts are. The Recon XZT is the smallest and most powerful gauge of its kind. With

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel)

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel) OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 7 03 Litho In U.S.A. (cre) 1 Part No. OVEN PARTS NOTE: The screws and nuts required to attach a part are listed immediately following that part.

More information

Galvanic Parts Per Million Dissolved Oxygen Systems

Galvanic Parts Per Million Dissolved Oxygen Systems Galvanic Parts Per Million Dissolved Oxygen Systems Model 900 Portable s Model 9100 Model 9200 Model 9300 The Royce line of PPM level dissolved oxygen (DO) analyzers is the largest, most varied line in

More information

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output. Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration

More information

Regards from the Team at Rheology Solutions.

Regards from the Team at Rheology Solutions. Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained

More information

spare parts Spare parts for 10 ton C-clamps Straightening > C-clamps > 10 ton

spare parts Spare parts for 10 ton C-clamps Straightening > C-clamps > 10 ton Straightening > C-clamps > 10 ton Spare parts for 10 ton C-clamps I-17475 10890 Repair kit for 10 ton NIKE CF110-310 I-AQU8 10945 Snap-on coupling male I-CF110C 10951 10 ton press cylinder 150 mm stroke

More information

An easy and flexible way to do gas detection.

An easy and flexible way to do gas detection. An easy and flexible way to do gas detection. 24 Plug-and-Play fieldreplaceable sensors including PID and Infrared options Up to 6 gases monitored simultaneously Optional integral sampling pump with strong

More information

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless) OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 3 05 Litho In U.S.A. (cre) 1 Part No. Rev.A OVEN PARTS 1 Literature Parts 4455994 Installation Instructions Use & Care Guide 8300346 Microwave

More information

OEM-EP Pressure Controllers

OEM-EP Pressure Controllers Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable

More information

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue

More information

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3

More information

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions Model PRO 9842 Installation Manual Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions This Unit Is Intended For Installation In Vehicles With 12 Volt Negative Ground Electrical

More information

Touchpoint Pro. Flexible Gas Control System

Touchpoint Pro. Flexible Gas Control System Touchpoint Pro Flexible Gas Control System The ideal safety system Honeywell s Touchpoint Pro makes gas control system design, installation, configuration and operation simple. Touchpoint Pro uses a building

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

How To Use An Irius Pid Detector

How To Use An Irius Pid Detector SIRIUS PID & 4-Gas Detector [ Compact and Versatile for all your needs] SIRIUS [ Maximum versatility in one hand] The new SIRIUS PID Detector combines incredible performance, versatility and ease of use

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

UFGS-28 33 00.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS-28 33 00.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-28 33 00.00 40 (February 2014) ----------------------------------- Preparing Activity: NASA Superseding UFGS-28 33 00.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Generator Parts List. GXi Part Number. Model Year. 5650,5650EL, 6500, 6500EL, 4550 Pro, 7550EL Pro DEK, STANLEY

Generator Parts List. GXi Part Number. Model Year. 5650,5650EL, 6500, 6500EL, 4550 Pro, 7550EL Pro DEK, STANLEY G01006 Air check valve for models 2006, G01107 Air filter Air filter module The air filter module comes with all the components ready to be assembled. The module includes the filter cover, filter media,

More information

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION AJ English version EDITION - 06/007 CODE - 9790 Parts catalog MÁQUINAS AGRÍCOLAS JACTO S.A. Rua Dr. Luiz Miranda, 650 7580-000 - Pompéia - SP - Brasil Tel.: +55 4 3405-00 - Fax: +55 4 345 306 E-mail: [email protected]

More information

Automated Lubrication Systems Parts & Accessories

Automated Lubrication Systems Parts & Accessories Automated Lubrication Systems Parts & Accessories (Truck and Trailer) Groeneveld USA, Inc. 2150 S. Central Expy. Suite 200 McKinney, TX 75070 Tel: 800.586.7283 Fax: 330.225.5213 Groeneveld USA, Inc. 2150

More information

HT3 series Peck Feed Drills, with Equal Drill Time

HT3 series Peck Feed Drills, with Equal Drill Time Parts Manual Ersatzteil Liste PL92-280 HT3 series Peck Feed Drills, with Equal Drill Time HT3 SERIES PECK DRILL HT 3 C 005 S E 40 RPM Family Spindle B = 1/2-20 Male Thread, Jacobs Chuck C = 3/8-24 Female

More information

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER Centralizes Monitoring and Alarming for Gas Transmitters and Fire Detectors. The QuadScan II receiver

More information

FSLIMRF05-10 - 15-20 - 25

FSLIMRF05-10 - 15-20 - 25 1. INTRODUCTION FSLIMRF is a fully wireless, battery-powered infrared beam barrier for the protection of doors and windows with alarm radio transmission. The barrier is made up of two aluminium sections

More information

3500/93 System Display

3500/93 System Display 3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide

More information

430 Power/Electronics Replacement

430 Power/Electronics Replacement Replacing the main board WARNING Before proceeding, turn off the main power switch and unplug the power cord. Caution Make sure you are properly grounded with an ESD strap before continuing. The main printed

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

How To Use A Gizmo 2.5 (Gizmo) With A Power Supply (Power Supply) And Power Supply For A Long Time (Power Source) (Power Cell) (Gigabone) (Microphone) (

How To Use A Gizmo 2.5 (Gizmo) With A Power Supply (Power Supply) And Power Supply For A Long Time (Power Source) (Power Cell) (Gigabone) (Microphone) ( Order form alid from May 2015 HMT331 Humidity and Temperature Transmitter or wall mounting aisala HUMIAP Humidity and Temperature Transmitter HMT330 1 0 A 1 PRI 1 Transmitter type HMT331 1 2 Wall probe

More information

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S *1756202470* 17562.0247.0 REV3 06/09 2012 Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S Issue Table description Issue n. of pages Overall view 06/2009 1 C.h.

More information

Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies REV. G Cooler is Better! TM Owner s Manual Walk-in Monitoring System 100 Used in UL Listed Door Panel Assemblies American Panel Corporation 5800 S.E. 78th Street, Ocala, Florida 34472-3412 Phone: (352)

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

Honeywell Analytics Lines of Business

Honeywell Analytics Lines of Business Honeywell Analytics Lines of Business Commercial Vulcain-brand gas detection from standalone units to fully engineered, multipoint systems, all offering cost-effective regulatory compliance» Applications:

More information

Part Name/Description Part Number Quantity. Power Cable 4000950-5 1

Part Name/Description Part Number Quantity. Power Cable 4000950-5 1 Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Power Cable 4000950-5 1 Raven Harness Adapter Kit 4100525 1 Installation Instructions

More information

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter MODEL PRO-9744 INSTALLATION MANUAL Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter This System Allows The Transmitter Buttons To Be

More information

EX-5175-EC Sensor/Transmitter Manual

EX-5175-EC Sensor/Transmitter Manual PO Box 979 Ann Arbor, MI 48106-0979 www.enmet.com EX-5175-EC Sensor/Transmitter Manual Manual Part Number 80003-099 MCN-13-008, 11/06/13 Table of Contents 1.0 INTRODUCTION... 1 1.1 Unpack... 1 1.2 Check

More information

Combustible Gas Transmitter 65-2400RK-05

Combustible Gas Transmitter 65-2400RK-05 Combustible Gas Transmitter 65-2400RK-05 Overview This detection insert describes the combustible gas transmitter. This insert also describes how to install, start up, maintain, and calibrate the transmitter.

More information

2 & 5-Wire Overfill Sensors

2 & 5-Wire Overfill Sensors 2 & 5-Wire Overfill Sensors Optic overfill sensors detect the presence of liquid at a preset level. The new Civacon Universal 2 & 5-Wire Sensor is fully compatible with all our current Sensors and Monitors,

More information

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual 0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security

More information

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular

More information

T a b l e o f C o n t e n t s

T a b l e o f C o n t e n t s w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company

More information

CO2 Alarm. Operation. Application

CO2 Alarm. Operation. Application CO Alarm 100-77V AC Supply Voltage Two pre-configured alarm and control thresholds Thresholds factory set to customer requirements on dispersive infrared sensing technology Optional internal audible alarm

More information

Automated Test System SIMPLICITY COUNTS MSA s New GALAXY GX2 Automated Test System / Advanced Safety Management Effortless Operation

Automated Test System SIMPLICITY COUNTS MSA s New GALAXY GX2 Automated Test System / Advanced Safety Management Effortless Operation Automated Test System SIMPLICITY COUNTS MSA s New GALAXY GX2 Automated Test System / Advanced Safety Management Effortless Operation SIMPLICITY COUNTS The new GALAXY GX2 Automated Test System provides

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG560-03-SL) HPX-1200BL, Black Anodized (FG560-03-BL)

HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG560-03-SL) HPX-1200BL, Black Anodized (FG560-03-BL) DATA SHEET HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG560-03-SL) HPX-1200BL, Black Anodized (FG560-03-BL) Overview With space for up to 12 modules, the HPX-1200 allows you to

More information

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC. 81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX

More information

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS 1. Check your gauges before you take them out of the packaging to make sure they are at 0 (zero) psi for both boost and fuel pressure.

More information

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797

More information

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by

More information