EX 2000/EX 2000 C/ GD 2000/GDP
|
|
|
- Julia Scott
- 9 years ago
- Views:
Transcription
1 Gas detectors EX 2000/EX 2000 C/ GD 2000/GDP 2000 Gas Discrimination (GD 2000 / GDP 2000) Explosimeters/ Catharometers Pocket size Long battery life High reliability New design for Enhanced performance ATEX Gas detection / stack gas monitoring
2 Let s protect your personnel together Going down a confined space You work in industrial hazardous areas likely to contain explosive gases and vapors. Oldham have designed a new explosimeter range to suit your requirements. We are aware of the potential risks that you face and identify the type of gas to ensure a total safety package. Ones of the smallest explosimeters on the market, with the best performance, the EX 2000, EX 2000 C, the GD 2000 and GDP 2000 identify the detected gas and the GDP 2000 displays its concentration level. Even more, they can discriminate between natural gas and other explosive gases. Light, practical and high-performance, the 2000 range of explosimeters are the ideal, compact gas detectors for industry. A tremendous efficiency Smart sensor Practical and modern design The 2000 Range of explosimeters are designed to ensure a total freedom in your personal activity : ergonomic keyboard : 3 tactile buttons high Visible alarm light weight High reliability The high quality detection sensor ensures measurement accuracy. The technique offers several advantages : exceptional response time 30 battery life hours poison resistance Standards Our explosimeters are in accordance : with the European certification : - surface : EEx iad IIC T4 - mine : EEx iad I with the North American certification : - class I groups A, B, C, and D Scale 1:1 Toxic products storage room
3 The 2000 Range of explosimeters are designed to minimize problems. Long battery life 12 hours with rechargeable batteries (Ni-Cd or Ni-mH) 30 hours with dry cell batteries Simple charger Intelligent two position charger 12 VDC charger Pocket size Maintenance and calibration very easy, simple and safe Friendly display panel Alphanumeric LCD display Alarm levels Units and range Maintenance mode (key) Extra brightness 2 position charger CR2002 Battery voltage Visual and audio alarms Red light flashing Pulsed alarm : 1 beep every 2 seconds for the first alarm threshold Pulsed alarm : 1 beep every 1 second for the second alarm threshold Adjustable alarm thresholds Auto operation status Auto test when switching on Auto diagnosis Confidence beep Battery and sensor faults (audio and visual alarm, continuous + pictograms displayed) 3 side visible Flash Buzzer 85 db
4 Main characteristics EX 2000 To measure the explosive gas concentration Detects all types of explosive gases Displays 0-100% LEL Can be programmed for a selected gas EX 2000 C To measure the concentration of explosive gases Only one detection sensor Detects and displays low concentration (0-100 LEL) and high concentration (0-100 %vol) Automatic switch over of range (catalytic or catharometric) GD 2000 To discriminate between natural gas and other explosive gases Detects all types of explosive gases with discrimination Displays simple messages for the user ie : - OK for no gas detected - NATURAL GAS or FLAMMABLE GAS GDP 2000 To discriminate between natural gas and other explosive gases, and to display the gas concentration Detects all types of explosive gas with discrimination Displays simple messages for the user ie : - OK for no gas detected - Nat G for «NATURAL GAS» or FLM G for «FLAMMABLE GAS» with the gas concentration detected in % LEL Options available Protective leather case Remote sampling kit Calibration kit ATEX electric pump Chargers Portable gas detectors
5 Technical characteristics Type EX 2000 EX 2000 C Manufacturer SA Function Explosimeter Explosimeter and catharometer Detected gases Explosive gas (%LEL) Explosive gas 0-100% LEL and 0-100% v/v gas Mode Continuous Display Gas detected value displayed Gas detected, value displayed Automatic switch from the catalytic range to the catharometric range Display panel Lighting up of LCD panel on request Message displayed The gas detected value The gas detected value Out of order Sensor fault Battery fault Operating check Alarms Gas alarm Correct operation "beep" signal that the manufactory can adjust or cancell on request Instantaneous and adjustable threshold A pre-programmed instantaneous alarm threshold Over scale alarm Visual alarm A red flash alarm Pictograms for each alarm type Audio alarm Buzzer 85 db at 30 cm Power supply 3 batteries R6 1,5 V 3 batteries R6 1,5 V 3 accus Ni-mH Ni-Cd or Ni-mH Battery lifetime 22 h with accus Ni-mH 22 h with Ni-mH 30 h with batteries 30 h with dry cell batteries Recharging time 4 h (auto adjusted charger) 4 h (auto regulated charger) 16 h (simple charger) 16 h (simple charger) Protection rating IP 66 Housing Antistatic polycarbonate Weight 230 g Type of clips Anti-sliping metallic clip Working temperature -25 C to +55 C -15 C to +45 C Dimensions 144 x 55 x 30 mm Approval EEx iad IIC T4 INERIS 98 D 5022 X Surface EEx iad I INERIS 98 Y 3001 X Mine INERIS 02ATEX0060 CSA class I groups A, B, C, D Sensor characteristics Type Plug-in catalytic Plug-in catalytic-catharometric Standard range % LEL 0-100% LEL or 0-5% CH4, 0-100% v/v 0-5 % CH4 Accuracy +/-1 % LEL or +/- 3 % +/-1% LEL or +/-3% Minimum detected 1 % LEL 1 % LEL Zero drift < 1 % of full scale per month 0,5% LEL methane per month Response time < 20 seconds at T90 Average lifetime 4 years (for normal operation) Belgium t (33) f (33) [email protected] Italia t f [email protected] Česká Republica t /3 f [email protected] Romania t (40) f (40) [email protected] Switzerland t (41) f (41) [email protected] United Kingdom t (44) f (44) [email protected] Deutschland WINTER t (49) f (49) [email protected]
6 GD 2000 GDP 2000 SA Explosimeter Explosimeter Natural gas, explosive gas Natural gas, explosive gas : 0-100% LEL Continuous Type of gas detected Gas type detected and value displayed OK, gas NATURAL, gas EXPLOSIVE Lighting up of LCD panel on request gas NATURAL, gas EXPLOSIVE Gas detected value Correct operation "beep" signal that the manufactory can adjust or cancell on request A 5 % LEL gas naturel threshold A 20%LEL natural gas threshold A 20% LEL threshold, butane equivalent -25 C to +55 C An early-warning alarm for natural gas A NATURAL gas alarm threshold Over scale alarm Over scale alarm A red flash alarm Pictograms for each alarm type Buzzer 85 db at 30 cm 3 batteries R6 1,5 V Ni-mH 22 h with Ni-mH 30 h with dry cell batteries 4 h (auto regulated charger) 16 h (simple charger) IP 66 Antistatic polycarbonate 230 g Anti-sliping metallic clip -25 C to +55 C 144 x 55 x 30 mm EEx iad IIC T 4 INERIS 98 D 5022 X Surface EEx iad I INERIS 98 Y 3001 X Mine INERIS 02ATEX0060 CSA class I groups A, B, C, D Precalibrated plug-in catalytic 0-100% LEL natural gas % LEL 0-100% LEL butane (standard) 0-100% LEL other gases +/-1% LEL or +/- 3% +/-1% LEL or +/- 3% 1 % LEL 1 % LEL 0,5% LEL methane per month < 1 % of full scale per month < 20 seconds at T90 4 years (for normal operation) Your agent or retailer Plant and head office : Z.I. Est - rue Orfila B.P ARRAS Cedex FRANCE Tel. : Fax : Web site : Explosimeters/ Catharometers This is not a contractually binding document. SA reserves the right to make any changes, without notice, to the technical characteristics of its equipement. Designed and created by Audace Edition ref.: EX/GDP/EXC/GD2000GB04
Gas and flame detection Stack gas and dust analysis
Gas and flame detection Stack gas and dust analysis Portable gas detectors Measurement and alarm units Detectors/transmitters Stack gas and dust analysers Accessories Gas detection / Stack gas monitoring
How To Use An Irius Pid Detector
SIRIUS PID & 4-Gas Detector [ Compact and Versatile for all your needs] SIRIUS [ Maximum versatility in one hand] The new SIRIUS PID Detector combines incredible performance, versatility and ease of use
SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P
SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P 2 Alarm Levels Bargraph + LED Indication of Gas Concentration Visual and Audible Signalization of Activated Alarm Levels 2 SPDT 5A/250V Output Relays Shock-Proof
ALTAIR 5X Multigas Detector Bid Specification
ALTAIR 5X Multigas Detector Bid Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Size, pumped unit with PID Weight Handling Case material Environmental
BadgeRAE. User Manual. PGM-1010 CO Detector PGM-1020 H 2. S Detector
BadgeRAE PGM-1010 CO Detector PGM-1020 H 2 S Detector User Manual 045-4001-000, Revision D, March 2005 READ BEFORE OPERATING This manual must be carefully read by all individuals who have or will have
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
Lockout Specification BW Clip Maintenance-free single gas detector
Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than
An easy and flexible way to do gas detection.
An easy and flexible way to do gas detection. 24 Plug-and-Play fieldreplaceable sensors including PID and Infrared options Up to 6 gases monitored simultaneously Optional integral sampling pump with strong
EXPLORER 4 MULTIPOINT
EXPLORER 4 MULTIPOINT Sampling gas analyser EXPLORER 4 MULTIPOINT is a sampling gas analyser, with 4 gas detection sensors ( LEL,H2S, O2 CO ) reliable and in accordance of the Rules with 15 sampling points
PortaSens ll G AS DETECTOR
PortaSens ll G AS DETECTOR ONE DETECTOR... FOR MANY GASES! Sensors can be exchanged quickly and easily without the need for calibration. Sensors are maintained in ready condition in the optional sensor
Sieger Searchpoint Optima Plus
Sieger Searchpoint Optima Plus Advanced infrared point gas detector Sieger Searchpoint Optima Plus Why Searchpoint Optima Plus is the right choice... The proven strengths of the original Searchpoint OPTIMA
RAEGuard EC FGM-13XX
RAEGuard EC FGM-13XX User s Guide P/N 033-4102-000 Rev B May 2007 - READ BEFORE OPERATING - This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining,
ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE
Emergency Response System INSTALLATION & PROGRAMMING GUIDE Copyright micron 2005 Contents Product Description 3 Console Operation Overview 4 Console Wiring Diagram 5 User Manual 6 Transmitter Assembly
Battery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized
Introduction. Refrigerant Leak Detecting System. Feature and Benefits
PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for
600-GD & 600-GDL 600 SERIES GAS DETECTOR
600-GD & 600-GDL 600 SERIES GAS DETECTOR INSTALLATION AND OPERATING INSTRUCTIONS This page has been deliberately left blank. Page 1 Table of Contents 1 WARRANTY...3 2 IMPORTANT...3 3 CAUTIONS WHEN USING
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
WD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
Application Requirement
Hazardous Gas Monitors Sensor Selection Overview Safety Monitoring (LEL) Toxic Limit Detection (PEL) Leak Detection Personal Safety Application Requirement Exposure Assessment (TWA) Ambient Air Quality
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
BEP FD-2 CONTOUR MATRIX FUME DETECTOR
BEP FD-2 CONTOUR MATRIX FUME DETECTOR INSTALLATION AND OPERATING INSTRUCTIONS Table of Contents 1 WARRANTY...3 2 IMPORTANT...3 3 CAUTIONS WHEN USING GAS SENSORS...3 4 FEATURES...4 5 SPECIFICATION...4 6
GasAlertMax XT II H 2 O 2 LEL
Simple operation with pump The rugged GasAlertMax XT II reliably monitors for up to four gas hazards and combines straightforward one-button field operation with an integrated sampling pump. Tamper-proof,
7 Lighting Technology
7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
Instructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
User's Guide. Pinless Moisture Meter. Model MO257
User's Guide Pinless Moisture Meter Model MO257 Introduction Congratulations on your purchase of the Extech MO257 Pinless Moisture Meter. The pinless moisture sensor monitors the moisture in wood and other
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: [email protected] url: http//www.len.
MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
Professional Series ATEX Portable Radios
Systemcom A/S [email protected] +47 900 20 366 Professional Series ATEX Portable Radios Product Launch, July 2005 Professional Series ATEX Objectives Provide our customers with best-in-class
Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure
QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER Centralizes Monitoring and Alarming for Gas Transmitters and Fire Detectors. The QuadScan II receiver
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
Battery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized
Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions
Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by
MiniRAE 2000. Portable VOC Monitor PGM-7600 OPERATION AND MAINTENANCE MANUAL
MiniRAE 2000 Portable VOC Monitor PGM-7600 OPERATION AND MAINTENANCE MANUAL (Document No.: 011-4001-000) Revision E, May 2005 i ATTENTION! For European Applications A. 0575 II 1G/2G DEMKO 03 ATEX 0204759X
GST301. (Single Protection Zone) Operation Manual
GST301 Gas Extinguishing Control Panel (Single Protection Zone) Operation Manual 2 of 19 CONTENTS 1 OVERVIEW... 4 2 TECHNICAL DATA... 4 3 STRUCTURES... 5 3.1 FRONT SURFACE DESCRIPTION... 5 3.1.1 Indicators...
din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate
traction BATTERIES din 50Ah/plate [h1 = 282, h2 = 305 mm length = b = 198 mm] 2 EPzS 100 L 2 Pg 190 L 100 45 6,8 5,7 3 EPzS 150 L 3 Pg 190 L 150 63 9,6 7,7 4 EPzS 200 L 4 Pg 190 L 200 81 12,4 9,9 5 EPzS
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
Chlorine Gas Detection System Operation & Maintenance
Chlorine Gas Detection System Operation & Maintenance Maynard King K&D Pratt Instrumentation 2011 Clean and Safe Drinking Water Workshop Chlorine Gas Detector Operation, Maintenance, Checks 1. Why you
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
Home Security Alarm System
Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better
0.9V Boost Driver PR4403 for White LEDs in Solar Lamps
0.9 Boost Driver for White LEDs in Solar Lamps The is a single cell step-up converter for white LEDs operating from a single rechargeable cell of 1.2 supply voltage down to less than 0.9. An adjustable
ALARMLINE ANALOGUE Linear Heat Detection System
ALARMLINE ANALOGUE Alarmline Analogue sensor cable senses temperature variations by continuously monitoring the resistance of specially doped N.T.C. polymeric insulation. A change in temperature produces
LITHIUM BALANCE CHARGER
LITHIUM BALANCE CHARGER A Microprocessor controlled, high-performance charger for NiCd/NiMH/LiPo/Pb batteries with an integral individual voltage balancer (LiPo only) Operating Manual Please read this
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Handheld portable appliance testers
PAT100 SERIES Handheld portable appliance testers PAT100 SERIES Handheld portable appliance testers Simple Tick/Cross, pass/fail indication plus measurement Battery powered with rechargeable options Includes
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
www.ringautomotive.co.uk Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A
SmartChargePro7 RSCPR7-12v, 7A SmartChargePro10 RSCPR10-12v, 10A SmartChargePro15 RSCPR15-12v, 15A SmartChargePro25 RSCPR25-12v, 2 / 6 / 12 / 25A SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A SmartChargePro50
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
2 Installation Explanation
Intelligent Solar Charge Controller Solar30 User s Manual Please read this instruction carefully before using it. SOLAR30 12V/24V AUTO WORK 1 Product introduction This controller is a kind of intelligent
site monitoring Kit Site Monitoring Kit User Manual we prove it.
site monitoring Kit 1 User Manual Site Monitoring Kit User Manual we prove it. 2 site monitoring Kit Content 1. Introduction 3 2. Content of the Site Monitoring Kit 4 3. Preparation 6 1. Positioning of
ALTAIR Family Gas Detectors A Tough Bunch
ALTAIR Family Gas Detectors A Tough Bunch ALTAIR: Maintenance-free Single Gas Detector ALTAIR 2X: Single Gas & Two-Gas Detector powered by MSA XCell Sensors ALTAIR PRO: Durable Single Gas Detector ALTAIR
Global Gas Detection and Monitoring Solutions
Global Gas Detection and Monitoring Solutions Portable Gas Detectors Fixed Detectors/Transmitters Fixed System Controllers Accessories Don t Buy Gas Detectors Subscribe to Gas Detection as a Service The
INTELLIGENT ENERGY ICHARGER & IDCHARGER
INTELLIGENT ENERGY ICHARGER & IDCHARGER www.cemont.com MICROPROCESSOR UNIVERSAL AUTOMATIC INTELLIGENT BATTERY CHARGERS WITH INVERTER TECHNOLOGY SAFE Will not damage your car s onboard electronics FAST
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
Ultima X Series Gas Monitors
Ultima X Series Gas Monitors For continuous monitoring of oxygen, toxics, and combustible gases Now with SIL 2 Certified Products MSA s Ultima X Series Gas Monitors are microprocessor-based transmitters
VoCALL - CFVCM/CFVCWM & CFVCX8. Fire Telephone & Disabled Refuge Network System. User Manual & Log Book
VoCALL - CFVCM/CFVCWM & CFVCX8 Fire Telephone & Disabled Refuge Network System User Manual & Log Book VoCALL Fire Telephone & Disabled Refuge Network System Introduction A VoCALL Emergency Voice Communications
Engineering Specifications XNX Universal Transmitter
Engineering Specifications XNX Universal Transmitter 1.0 General Description: The XNX Universal Transmitter is a comprehensive solution designed to operate in hazardous locations and utilize sensor technologies
AUTOMATIC LPG BOOKING, LEAKAGE DETECTION AND A REAL TIME LPG MEASUREMENT MONITORING SYSTEM
AUTOMATIC LPG BOOKING, LEAKAGE DETECTION AND A REAL TIME LPG MEASUREMENT MONITORING SYSTEM R.Padmapriya, E.Kamini, [email protected],[email protected], IV Year Electronics and Communication Engineering,
S100. GSM House Alarm System. Http://www.GSMalarmsystem.com
S100 GSM House Alarm System Http://www.GSMalarmsystem.com 1. Brief introduction The GSM Alarm System is a new security protection solution special for home, house and office and other applications. It
Digital Ground Resistance Tester. Models 4620 & 4630. Digital Ground Resistance Tester
Digital Ground Resistance Tester Models 4620 & 4630 Digital Ground Resistance Tester Models 4620 and 4630 perform both ground resistance and soil resistivity tests. These testers measure from 0 to 2000Ω,
EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call 0333 6000 600
EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM Nationwide Low Call 0333 6000 600 WHY BUY WHEN YOU CAN HIRE SlopeView TLL-90 User Guide V20100426 1 CONTENT Title Page 1 Introduction
PowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Certificate of Conformity
Applicant: Mine Safety Appliances Co. 1000 Cranberry Woods Drive Cranberry Township PA 16066 United States of America Electrical Apparatus: Altair 4 / 4X Diffusion Multi-gas Detector Type of Protection:
UniOP epad33 and epad33t
UniOP epad33 and epad33t The epad33 and epad33t are state-of-the-art HMI devices with a 10.4 graphic display and a complete keypad. The aluminum bezel offers an appealing look in a rugged and convenient
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
Hydrogen Leak Detection. 9012 XRS system. The complete system for leak detection using hydrogen gas
Hydrogen Leak Detection 9012 XRS system The complete system for leak detection using hydrogen gas Yes, it leaks but where? Telephone cables Gas-filled Petrol stations Gas pipelines power cables Heating
EzFlex Combustible Gas Leak Detector Model EZ40
User's Guide EzFlex Combustible Gas Leak Detector Model EZ40 Introduction Congratulations on your purchase of the Extech EZ40 Combustible Gas Leak Detector. The EZ40 detects the presence of combustible
Saft Reliable energy for the internet of things. A wide range of energy solutions for sensing devices
Saft Reliable energy for the internet of things A wide range of energy solutions for sensing devices Saft The fit and forget energy solution for the internet of things Wireless sensors are increasingly
CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor
CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5
SpO2 PULSE OXYMETER MD-300
MD-300 C MD-300 A MD-300 D MD-300 B MD-300 F MD-300 I MD-300 Z Finger clip ADULT Finger clip PEDIATRIC Soft tip ADULT Wrap ADULT -> PEDIATRIC Wrap PEDIATRIC -> NEONATE Y Type Pulse oxymètre portable MD-300C
GSM home alarm system s manual
GSM home alarm system s manual I. Main features: 1, Eight wireless LED zone, and four wired zone 2, Two-way to communication 3, The system supports the GSM cell phones, no need the fixed telephone line.
UM-X Field display for continous level sensors
Technical Documentation Field display for continous level sensors 10/2007 Edition: 1 Item No.: 207120 FAFNIR GmbH Bahrenfelder Str. 19 D-22765 Hamburg Telephone: +49 (0)40-39 82 07-0 Fax: +49 (0)40-3 90
User Guide for the DS7060 Control/Communicator
DS7060 User Guide Copyright 1996-97 Detection Systems, Inc. User Guide for the DS7060 Control/Communicator Copyright 1996-97 Detection Systems, Inc. Detection Systems, Inc., 130 Perinton Parkway, Fairport,
Fire & Security DETECTORS
Fire & Security DETECTORS Smoke Sensitivity 0.98 ~.0%/ft Obscuration Ceiling Spacing 50 foot rating for heat sensor Temperature Range 10ºC to 50ºC Humidity 0 to 95% RH, no condensation or icing Dimensions
USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM
USER MANUAL OPERATION AND USE OF CAR WITH Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM Page 2 z 7 Table of contents 1. STARTING THE ENGINE... 3 2. CONTROL PANEL... 3 2.1 Indication of the current level
UFGS-28 33 00.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-28 33 00.00 40 (February 2014) ----------------------------------- Preparing Activity: NASA Superseding UFGS-28 33 00.00 40 (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS
User s Manual AURORA 1.2K/2.2K
User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable
User Manual GSM Alarm System. www.deltasecurity.cn. All rights reserved by Delta Security Co., Ltd
User Manual GSM Alarm System All rights reserved by Delta Security Co., Ltd Dear Clients, Thank you for using our GSM Alarm System. We are committed to giving you the best home security available today
Analogue addressable devices
Discovery Analogue addressable devices from Channel Safety Systems Discovery Analogue addressable devices Discovery is a range of high-specification, intelligent fire detectors that are developed to meet
Digital Transformer Ratiometer DTR Model 8500
Digital Transformer Ratiometer DTR Model 8500 The DTR Model 8500 from AEMC Instruments is a portable digital transformer ratiometer designed for on-site testing of power, potential and current transformers.
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
Gasman Personal Gas Monitor
Personal Gas Monitor User Manual M07630 December 2007 Issue 6 Safety information: Read and understand all instructions in the operation section of this manual before use. Do not substitute components as
Stove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
Operating Manual Remote Cost Control Monitor
Operating Manual Remote Cost Control Monitor INTRODUCTION: Congratulations on purchasing the Remote Cost Control. This is a state-of-the-art power monitoring socket that is highly accurate and easy to
IO-DIM6 6-Channel, Digital to Analogue Converters
Page 1 of 6 IO-DIM6 6-Channel, Digital to Analogue Converters Features: Benefits: Input status indication Calibrated output DIN Rail mounting Expands controller input capacity Fault finding LED indication
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
Measuring electric and magnetic fields
NARDA BROADBAND FIELD METER NBM-520 Measuring electric and magnetic fields ranging from high frequency to microwaves Non-directional measurement using isotropic probes for applications in the frequency
USB-500 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
Wahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
Galleon 6-10K Online UPS. Voltronic Power Technology Corporation
Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection
Buckeye Detection Systems Fixed Detection Systems Application Survey
Buckeye Detection Systems Fixed Detection Systems Application Survey Channel Partner Representative : Company Name: Representative: BDS Representative: Client Contact Information : Company Name: Company
SECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS
SECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS PART 1 - GENERAL 1.01 Section Includes A. Requirements for provision of the Natural Gas (CH4), Carbon Monoxide (CO)
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success
Labkotec SET Labkotec separator alarm system protecting our environment Designed to comply EN 858-1&2 and PPG3 norms Warns of excessive levels of oil, sludge & liquids Prevents pollution incidents Fail-safe
