DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors

Size: px
Start display at page:

Download "DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors"

Transcription

1 DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors Faster response higher accuracy greater stability longer life. Dräger electrochemical sensors offer all these benefits. The robust and longlife sensors are used for the selective measurement of the smallest concentrations of toxic gases and oxygen in ambient air. ST

2 02 DrägerSensor EC Electrochemical Sensors Benefits Long life time The use of resistant plastics, such as PTFE, and the purest catalysts make it possible to achieve a long, wear-free measurement function over long periods. A patented internal pressure compensation mechanism compensates adverse environmental influences from changes in humidity, temperature expansion and weatherrelated variations in air pressure. A large electrolytic reservoir and large electrode areas provide sufficient reserves for a long life time, even in industrial environments. Ready for use immediately All sensors are factory calibrated, and these values are saved in the internal, electronic memory. This means that sensors in the field can be used immediately. The high-quality technical construction guarantees a long stability and low, age-related drift. Comprehensive range of applications All sensors have an internal temperature sensor. Between -40 C and +65 C, the temperature influence is compensated to zero, and the sensitivity is automatically adjusted. The internal pressure compensation allows the transmitters to be used during extreme low pressure, and high atmospheric pressure. In combination with exchangeable, selective filters, it is possible to reduce the influence of disruptive cross-sensitivities. Performance Low detection limits Optimised selectivity Excellent accuracy of measurements Fast response High stability Wide range of applicational areas Long life time Comprehensive self-diagnosis options No position dependency Advanced sensor technology It is possible to choose between oxygen sensors for partial pressure measurement or volume percent measurement. Acid gas sensor AC with unlimited life time, due to refillable electrolyte. Sensors with organic electrolyte for detection limits in lower ppb range

3 DrägerSensor EC Electrochemical Sensors 03 System components Dräger Polytron 7000 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and oxygen gas measurement applications on a single platform. It is meeting the requirements of the compliance market as well as the high specification requirements of customized solutions. ST ST Dräger Polytron 3000 The Dräger Polytron 3000 is an intrinsically safe gas detector for the continuous monitoring of more than 60 toxic gases and oxygen in ambient air. It is the part of a new generation of gas detectors developed on a modular platform. Communication to the central control system is done via a 4 to 20 ma signal. Dräger Polytron 7500 The Dräger Polytron 7500 is a gas detector for nitrogen trifluoride (NF 3 ), fluorinated and chlorinated hydrocarbons in ambient air ST Dräger REGARD control system Tried and tested thousands of times and infinitely flexible. The modular Regard control system can be individually adapted to any monitoring task. Suitable for SIL 2 systems, the Regard system is also ATEX approved, and meets EMC directive standards.

4 04 DrägerSensor EC Electrochemical Sensors System components Dräger REGARD-1 The Dräger REGARD-1 is a standalone, self contained single channel control system for the detection of Toxic, Oxygen and Ex hazards. The control system is fully configurable for a single input from either a 4 to 20 ma transmitter or a Dräger Polytron SE Ex measuring head. D ST Dräger REGARD 3900 The Dräger REGARD 3900 is a standalone, self contained control system for the detection of Toxic, Oxygen and Ex hazards. The control system is fully configurable between 1 and 16 channels, depending upon the type and quantity of input/output boards installed. Accessories Gassing adapter Hard PE adapter for gassing of electrochemical sensors in Dräger Transmitters during calibration. Also suitable for continuous gassing, when used with a pump. Order No.:

5 DrägerSensor EC Electrochemical Sensors 05 Accessories Remote calibration adapter For calibrations in transmitters with electrochemical sensors, which are positioned in areas with restricted access Order No.: ST ST Dust filter Hydrophobic dust filter for electrochemical polytron sensors (see also the corresponding sensor data specification). Order No.: Test gas ampoules ST For use with the calibration bottle. Test gas ampoules are available for the following gases/concentrations: Test gas ampoule SO 2 10 ppm Test gas ampoule SO 2 50 ppm Test gas ampoule NO 2 10 ppm Test gas ampoule NO 2 50 ppm Test gas ampoule CO 100 ppm Test gas ampoule CO 300 ppm Test gas ampoule NH ppm Test gas ampoule NH 3 50 ppm Test gas ampoule SO 2 1 ppm Test gas ampoule SO 2 4 ppm Test gas ampoule Cl2 8 ppm Test gas ampoule HCN 10 ppm Test gas ampoule H 2 S 10 ppm Test gas ampoule H 2 S 20 ppm Test gas ampoule H 2 S 40 ppm Test gas ampoule H 2 S 100 ppm

6 06 DrägerSensor EC Electrochemical Sensors Calibration/process adapter AC Gassing adapter, suitable for calibration of DrägerSensor AC (Part No.: ) and for continuous gassing when used with a pump. Order No.: ST

7 DrägerSensor EC Electrochemical Sensors 07 Accessories Splash guard Protects the DrägerSensor AC (Part No.: ) against dripping water. Order No.: ST ST Viton calibration adapter Soft adapter, made of Viton, for gassing during zero point test and when calibrating electrochemical sensors in Dräger Transmitters. Order No.: Calibration bottle A plastic, 3-litre container for generating a defined concentration of gas, using test gas ampoules, when calibrating electrochemical sensors. Order No.: ST ST Start up kit AC, AC L and HF/HCI L For filling of sensors (Part No , ) and Dräger Polytron HF/HCl L (Part No ), consisting of bottles with electrolyte and pipette. Order No.:

8 08 DrägerSensor EC Electrochemical Sensors Accessories Selective filter Selective filters absorb interfering gases from the ambient air. They are located in the sensor opening of the DrägerSensor and can easily be replaced if worn out.the following selective filters are available (see also the corresponding sensor data specification): Selective filters for use with DrägerSensors: CO ( ) A2F CO LS ( ) A2F COCI2 ( ) K2F H2 ( ) A2F HCI ( ) NF HCN ( ) BF Hydride ( ) CF NO 2 ( ) CF PH3/AsH3 ( ) MF SO 2 ( ) KIF Sensor test set HF/HCI L Test set for generating an HCI test gas concentration for functional tests on the DrägerSensor AC and Dräger Polytron L HF/HCI Order No's.: Bottle Chemical set ST Related Products

9 DrägerSensor EC Electrochemical Sensors 09 DrägerSensor IR Upgrade from Catalytic bead to infrared technology with ease using the DrägerSensor IR. The Sensor IR can replace catalytic ex-sensors (pellistors) from the majority of manufacturers without replacing controllers, cables, junction boxes or control systems. ST

10 10 DrägerSensor EC Electrochemical Sensors Related Products Catalytic Bead DrägerSensors The Dräger Catalytic Bead Sensors is designed for the continuous monitoring and detection of combustible gases and vapours with different versions for different applications or concentrations. D

11 Notes DrägerSensor EC Electrochemical Sensors 11

12 12 DrägerSensor EC Electrochemical Sensors Notes Communications & Sales Marketing PP LE Printed in Germany Chlorine-free environmentally compatible Subject to modifications 2014 Drägerwerk AG & Co. KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee Lübeck, Germany Locate your Regional Sales Representative at:

Dräger PARAT Escape Hoods

Dräger PARAT Escape Hoods Dräger PARAT Escape Hoods Airborne toxins present an immediate danger to the health of a workforce. When environments turn toxic, a fast, safe escape is crucial. Dräger PARAT Escape Hoods are designed

More information

Dräger Alcotest 9510 Evidential Alcohol Measuring Device

Dräger Alcotest 9510 Evidential Alcohol Measuring Device Dräger Alcotest 9510 Evidential Alcohol Measuring Device The Dräger Alcotest 9510 is an advanced breath alcohol measuring instrument for evidential applications. It is designed to comply with national

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

Sekusept Cleaner Liquid Cleaning Agent Cleaning, Desinfecting and Drying

Sekusept Cleaner Liquid Cleaning Agent Cleaning, Desinfecting and Drying Sekusept Cleaner Liquid Cleaning Agent Cleaning, Desinfecting and Drying Concentrated liquid cleaning agent for manual cleaning of respiratory masks, respiratory protection equipment, diving apparatus

More information

Gas sensors for greenhouse measurements

Gas sensors for greenhouse measurements HTG 2020 Fresh Valley Installation Dr. Martin Paplewski Gas sensors for greenhouse measurements Agenda 1. Applications for Gas sensors Which gases should be measured? Which sensor technology should be

More information

Dräger Polytron SE Ex Fixed Gas Detector

Dräger Polytron SE Ex Fixed Gas Detector Dräger Polytron SE Ex Fixed Gas Detector The Dräger Polytron SE Ex... DD sensing heads are gas detectors for the continuous monitoring of flammable gases and vapors in the ambient air. The measurement

More information

Dräger X-dock Release Notes Software-Update 01.07.00 and Manager Software 1.7.0

Dräger X-dock Release Notes Software-Update 01.07.00 and Manager Software 1.7.0 Supported operating system (X-dock Manager) Windows 7 Windows 8 Windows Server 2008 R2 Windows Server 2012 R2 Supported firmware versions (X-dock Manager) X-am 2000: > = v6.0 X-am 2500/5x00: > = v6.6 Pac

More information

Online Infrared Flue Gas Analyzer Gasboard 3000

Online Infrared Flue Gas Analyzer Gasboard 3000 Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume

More information

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject

More information

Application Requirement

Application Requirement Hazardous Gas Monitors Sensor Selection Overview Safety Monitoring (LEL) Toxic Limit Detection (PEL) Leak Detection Personal Safety Application Requirement Exposure Assessment (TWA) Ambient Air Quality

More information

Pac III. Single Gas Detection Instruments

Pac III. Single Gas Detection Instruments Pac III. Single Gas Detection Instruments ST-179-98 Pac = Personal Air Control only one unit for selection of a sensor from the extensive range of DrägerSensors suitable for measuring different toxic

More information

Engineering Specifications XNX Universal Transmitter

Engineering Specifications XNX Universal Transmitter Engineering Specifications XNX Universal Transmitter 1.0 General Description: The XNX Universal Transmitter is a comprehensive solution designed to operate in hazardous locations and utilize sensor technologies

More information

Dräger PSS 3000 Self Contained Breathing Apparatus

Dräger PSS 3000 Self Contained Breathing Apparatus Dräger PSS 3000 Self Contained Breathing Apparatus The Dräger PSS 3000 is a new generation of high performing breathing apparatus for firefighters. Combining comfort with exceptional pneumatic performance,

More information

EXPLORER 4 MULTIPOINT

EXPLORER 4 MULTIPOINT EXPLORER 4 MULTIPOINT Sampling gas analyser EXPLORER 4 MULTIPOINT is a sampling gas analyser, with 4 gas detection sensors ( LEL,H2S, O2 CO ) reliable and in accordance of the Rules with 15 sampling points

More information

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work * How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work * 1. Oxygen sensor detection principle Most portable or survey instruments used for workplace evaluation of oxygen concentrations

More information

Operation & Maintenance Manual. Electrochemical (EC) Gas Sensor Family

Operation & Maintenance Manual. Electrochemical (EC) Gas Sensor Family Operation & Maintenance Manual Electrochemical (EC) Gas Sensor Family For Detection of Oxygen and Toxic Gases Important: Read and understand contents prior to first use. Improper use or operation could

More information

Technical data sheet TDS0070

Technical data sheet TDS0070 Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier

More information

Ultima X Series Gas Monitors

Ultima X Series Gas Monitors Ultima X Series Gas Monitors For continuous monitoring of oxygen, toxics, and combustible gases Now with SIL 2 Certified Products MSA s Ultima X Series Gas Monitors are microprocessor-based transmitters

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air

More information

Gas and flame detection Stack gas and dust analysis

Gas and flame detection Stack gas and dust analysis Gas and flame detection Stack gas and dust analysis Portable gas detectors Measurement and alarm units Detectors/transmitters Stack gas and dust analysers Accessories Gas detection / Stack gas monitoring

More information

ALTAIR 5X Multigas Detector Bid Specification

ALTAIR 5X Multigas Detector Bid Specification ALTAIR 5X Multigas Detector Bid Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Size, pumped unit with PID Weight Handling Case material Environmental

More information

ABSTRACT INTRODUCTION

ABSTRACT INTRODUCTION Infrared Technology for Fail-To-Safe Hydrocarbon Gas Detection Authors: Dr. Shankar Baliga is Manager of Research & Development at General Monitors. He has a Ph.D. in Physics from Ohio State University

More information

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features: GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low

More information

Polaris 5xx/7xx Medical Lights and Video

Polaris 5xx/7xx Medical Lights and Video Polaris 5xx/7xx Medical Lights and Video Without light, surgery just isn t possible. Sufficient light is one of the fundamental requirements for the operating theatre. The Polaris lights were designed

More information

How To Use An Irius Pid Detector

How To Use An Irius Pid Detector SIRIUS PID & 4-Gas Detector [ Compact and Versatile for all your needs] SIRIUS [ Maximum versatility in one hand] The new SIRIUS PID Detector combines incredible performance, versatility and ease of use

More information

Dräger Communication Systems

Dräger Communication Systems Dräger Communication Systems Clear and trouble-free communication is a must during deployments. Especially when it comes to environments with high noise levels such as fires and other disasters, it s crucial

More information

Alphasense Application Note AAN 105-03 DESIGNING A POTENTIOSTATIC CIRCUIT

Alphasense Application Note AAN 105-03 DESIGNING A POTENTIOSTATIC CIRCUIT AAN 10503 DESIGNING A POTENTIOSTATIC CIRCUIT Introduction In a threeelectrode sensor, each electrode has a specific use: The working electrode responds to the target gas, either oxidising or reducing the

More information

www.klmtechgroup.com TABLE OF CONTENT

www.klmtechgroup.com TABLE OF CONTENT Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES

More information

Attachment to GB/FME/ExTR08.006/05 Electrical Apparatus FEP3** ProcessMaster Electromagnetic Flowmeter FEP5** ProcessMaster Electromagnetic Flowmeter FEH3** HygienicMaster Electromagnetic Flowmeter FEH5**

More information

An easy and flexible way to do gas detection.

An easy and flexible way to do gas detection. An easy and flexible way to do gas detection. 24 Plug-and-Play fieldreplaceable sensors including PID and Infrared options Up to 6 gases monitored simultaneously Optional integral sampling pump with strong

More information

D-9282-2009. Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM

D-9282-2009. Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM D-9282-2009 Gas supply secure at a glance DRÄGER ALARM MANAGEMENT SYSTEM 02 Alarm Management System The central gas supply is one of the hospital s life support systems, and as such is subject to special

More information

Dew-Point Measurement Solutions

Dew-Point Measurement Solutions Dew-Point Measurement Solutions www.michell.com Dew-Point Measurement Solutions Special Features No downtime Michell Instruments offers a unique sensor exchange programme, which means that you will never

More information

D-39740-2011. Next-generation LED phototherapy NanoBlu 500

D-39740-2011. Next-generation LED phototherapy NanoBlu 500 D-39740-2011 Next-generation LED phototherapy NanoBlu 500 02 Is there a powerful phototherapy device that s really compact? D-3534-2011 03 BETTER TREaTMENTS SuPPoRT BETTER outcomes The effective treatment

More information

Advanced Solutions for Gas Monitoring

Advanced Solutions for Gas Monitoring Continuous Emissions Monitoring Stack Testing Process Monitoring Quality Control Engine Exhaust Gas Monitoring Workplace Air Quality Monitoring Combustion Research Emergency Rescue Services Advanced Solutions

More information

Single-Gas Detector. Long-term solution. h Class I, Div. 1, Gr. A, B, C, D 4 5062-26-NCL-EN

Single-Gas Detector. Long-term solution. h Class I, Div. 1, Gr. A, B, C, D 4 5062-26-NCL-EN Single-Gas Detector H 2 S, CO, O 2, SO 2, NH 3, PH 3, Cl 2, ClO 2, NO, NO 2, HCN, ETO, O 3 Long-term solution Compact and affordable, the GasAlert Extreme reliably monitors for any single gas hazard within

More information

RAEGuard EC FGM-13XX

RAEGuard EC FGM-13XX RAEGuard EC FGM-13XX User s Guide P/N 033-4102-000 Rev B May 2007 - READ BEFORE OPERATING - This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining,

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

Buckeye Detection Systems Fixed Detection Systems Application Survey

Buckeye Detection Systems Fixed Detection Systems Application Survey Buckeye Detection Systems Fixed Detection Systems Application Survey Channel Partner Representative : Company Name: Representative: BDS Representative: Client Contact Information : Company Name: Company

More information

The Ambient Air Monitoring System

The Ambient Air Monitoring System The Ambient Air Monitoring System 1.0 Introduction: The Ambient Air Monitoring System (AAMS) can measure a range of toxic and flammable gases, particulate matter, meteorological and environmental parameters

More information

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE Table of Contents 1 Meridian Overview 2 Meridian Specifications 4 Supported Gases 5 Multi Sensor Configurations 6 Technical Drawings 16 Accessories

More information

Sieger Searchpoint Optima Plus

Sieger Searchpoint Optima Plus Sieger Searchpoint Optima Plus Advanced infrared point gas detector Sieger Searchpoint Optima Plus Why Searchpoint Optima Plus is the right choice... The proven strengths of the original Searchpoint OPTIMA

More information

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons

More information

Lockout Specification BW Clip Maintenance-free single gas detector

Lockout Specification BW Clip Maintenance-free single gas detector Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than

More information

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure

More information

ALTAIR Family Gas Detectors A Tough Bunch

ALTAIR Family Gas Detectors A Tough Bunch ALTAIR Family Gas Detectors A Tough Bunch ALTAIR: Maintenance-free Single Gas Detector ALTAIR 2X: Single Gas & Two-Gas Detector powered by MSA XCell Sensors ALTAIR PRO: Durable Single Gas Detector ALTAIR

More information

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter Product Bulletin CD-Pxx-00-1 Code No. LIT-216525 Issued December 6, 2010 Supersedes September 12, 2008 Johnson Controls offers a complete line of Carbon Dioxide

More information

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI) FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous

More information

Global Gas Detection and Monitoring Solutions

Global Gas Detection and Monitoring Solutions Global Gas Detection and Monitoring Solutions Portable Gas Detectors Fixed Detectors/Transmitters Fixed System Controllers Accessories Don t Buy Gas Detectors Subscribe to Gas Detection as a Service The

More information

Session Fourteen Introduction to functional safety standards in gas detection

Session Fourteen Introduction to functional safety standards in gas detection Session Fourteen Introduction to functional safety standards in gas detection Preeju Anirudhan Marketing Manager Plant Safety & Operations, Draeger Safety Pacific Pty Ltd Objective: The objective of this

More information

ORBISPHERE M1100: CUSTOMER SUCCESS STORY - CARLSBERG

ORBISPHERE M1100: CUSTOMER SUCCESS STORY - CARLSBERG PRACTICE REPORT PROCESS ANALYSIS OXYGEN MEASUREMENT BREWING ORBISPHERE M1100 CUSTOMER SUCCESS STORY - CARLSBERG Authors: Stephen Bell, Global Product Line Manager, HACH LANGE S.A. Frank Dunand. Senior

More information

Dräger University College of Operations Maintenance Training Courses

Dräger University College of Operations Maintenance Training Courses ST-46-2007 Dräger University College of Operations Maintenance Training Courses SCBA BG-4 rebreather DeteCtOr tubes & PUmPS GAS DeteCtiOn POrtABleS SUPPlieD Air respirators lar V military law enforcement

More information

Sample Usage Protocol Jaundice Meter JM-105

Sample Usage Protocol Jaundice Meter JM-105 D-94164-2013 Sample Usage Protocol Jaundice Meter JM-105 This Sample Usage Protocol is provided as a template for creating a facility or department-specific protocol for using the Dräger Jaundice Meter

More information

SPECIALISTS FOR YOUR SAFETY PORTABLE GAS DETECTION FROM DRÄGER SAFETY

SPECIALISTS FOR YOUR SAFETY PORTABLE GAS DETECTION FROM DRÄGER SAFETY ST-9527-2007 ST-2786-2003 SPECIALISTS FOR YOUR SAFETY PORTABLE GAS DETECTION FROM DRÄGER SAFETY GASMESSTECHNIK PERSONENSCHUTZTECHNOLOGIE TAUCHTECHNIK SYSTEMLÖSUNGEN DIENSTLEISTUNGEN INTRODUCTION PORTABLE

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Dräger PSS 7000 SCBA Self-Contained Breathing Apparatus

Dräger PSS 7000 SCBA Self-Contained Breathing Apparatus Dräger PSS 7000 SCBA Self-Contained Breathing Apparatus Before you can protect the lives of others, you have to protect yourself. The Dräger PSS 7000 SCBA breathing apparatus provides unmatched comfort,

More information

DISSOLVED OXYGEN PROBE

DISSOLVED OXYGEN PROBE 51970-88 DISSOLVED OXYGEN PROBE Introduction This instruction sheet provides information on the Hach Dissolved Oxygen Probe for use with the sension 6 Dissolved Oxygen Meter. The Dissolved Oxygen Probe

More information

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100 Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When

More information

Chlorine Gas Detection System Operation & Maintenance

Chlorine Gas Detection System Operation & Maintenance Chlorine Gas Detection System Operation & Maintenance Maynard King K&D Pratt Instrumentation 2011 Clean and Safe Drinking Water Workshop Chlorine Gas Detector Operation, Maintenance, Checks 1. Why you

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

Ion Selective Electrodes

Ion Selective Electrodes Ion Selective Electrodes OAKTON has a large selection of Ion Selective Electrodes () to suit a wide variety of applications. Each electrode has a typical response time of 20 to 30 seconds but will vary

More information

GasAlertMax XT II H 2 O 2 LEL

GasAlertMax XT II H 2 O 2 LEL Simple operation with pump The rugged GasAlertMax XT II reliably monitors for up to four gas hazards and combines straightforward one-button field operation with an integrated sampling pump. Tamper-proof,

More information

ngenieros Ingenieros Asociados De Control S.L.

ngenieros Ingenieros Asociados De Control S.L. ngenieros sociados de ontrol 1 Company founded in 1985 to serve commercial and technical assistance in the fields of instrumentation, control and installation for all types of industries. We offer top

More information

Ammonia Detection System Codes and Design Specifications. Brian EuDaly, P.E. Calibration Technologies, Inc.

Ammonia Detection System Codes and Design Specifications. Brian EuDaly, P.E. Calibration Technologies, Inc. Ammonia Detection System Codes and Design Specifications Brian EuDaly, P.E. Calibration Technologies, Inc. Ammonia Detection Code Requirements IIAR-2A-2008 ASHRAE 15-2010 NFPA 1 2012 UMC 2012 Preprint

More information

RGC-IR Remote Gas Calibrator for IR400

RGC-IR Remote Gas Calibrator for IR400 Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000 IMR 5000 Continuous Flue Gas Monitoring System The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000

More information

Agila Ceiling Supply Unit Medical Supply Units

Agila Ceiling Supply Unit Medical Supply Units Agila Ceiling Supply Unit Medical Supply Units Featuring a wide range of configurations and options to choose from, the compact and highly ergonomic Dräger Agila family uses a minimum of precious care

More information

World s Best Oil in Water Analyzers

World s Best Oil in Water Analyzers World s Best Oil in Water Analyzers Advanced Water Measurement and Analysis Advanced Sensors Ltd is the leading global supplier of Oil in Water analyzers to the Oil and Gas Industries. We provide innovative

More information

Automotive Air Quality Sensors: industrial innovations to protect people s health

Automotive Air Quality Sensors: industrial innovations to protect people s health Pioneering sensor and detector technology Automotive Air Quality Sensors: industrial innovations to protect people s health COST Action TD1105 3 rd Management Committee Meeting Barcelona, Spain, 21st June

More information

The column to efficient care DRÄGER GEMINA DUO

The column to efficient care DRÄGER GEMINA DUO MT-0798-2008 The column to efficient care DRÄGER GEMINA DUO 02 Dräger a century of care competence Today, hospitals are under increased pressure to provide state-of-the-art care with less staff and on

More information

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer Procedure No: SOP-039 Revision No: 1.1 January 21, 2011 Page No.: 1 of 11 1. INTRODUCTION AND SCOPE This document will outline specifics with regards to portable sampling analysis utilizing and operating

More information

PortaSens ll G AS DETECTOR

PortaSens ll G AS DETECTOR PortaSens ll G AS DETECTOR ONE DETECTOR... FOR MANY GASES! Sensors can be exchanged quickly and easily without the need for calibration. Sensors are maintained in ready condition in the optional sensor

More information

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER Centralizes Monitoring and Alarming for Gas Transmitters and Fire Detectors. The QuadScan II receiver

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

White Paper. Detecting Hydrogen Sulfide Gas and Understanding its Danger in the Field. Introduction

White Paper. Detecting Hydrogen Sulfide Gas and Understanding its Danger in the Field. Introduction White Paper PN FGD_TWP_H2S_Hydrogen_Sulfide_Gas_Understand_Danger January 2015 Detecting Hydrogen Sulfide Gas and Understanding its Danger in the Field Introduction Many oil fields, especially mature ones,

More information

Our solutions for oil & gas exploration and production LOREM IPSUM. 3. 3. Überschrift

Our solutions for oil & gas exploration and production LOREM IPSUM. 3. 3. Überschrift ST-34-2002 D-109322-2013 Our solutions for oil & gas exploration and production LOREM IPSUM 2. 2. ÜBERSCHRIFT 3. 3. Überschrift Lorem ipsum dies dies ist ist eine eine lange Beschreibung über über mehrer

More information

Laser Diode Gas Sensors

Laser Diode Gas Sensors Laser Diode Gas Sensors Photonic Sensors Swiss Laser Net Workshop Biel 17.09.09 Thomas Hessler Overview Leister and ist photonic activities TDLS detection principle TDLS product plattform Applications

More information

Car and commercial cial air conditioning service solutions

Car and commercial cial air conditioning service solutions Car and commercial cial air conditioning service solutions THE STANDARD IN INFORMATION AND DIAGNOSTICS SYSTEMS INTRODUCTION For the KoolKare range of vehicle air conditioning service equipment we went

More information

ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 ENG 97D STAND-ALONE MANUAL. Manual Part Number 80003-035 MCN-389, 01/21/08

ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 ENG 97D STAND-ALONE MANUAL. Manual Part Number 80003-035 MCN-389, 01/21/08 PO Box 979 Ann Arbor, MI 48106-0979 ENG 97D STAND-ALONE MANUAL Manual Part Number 80003-035 MCN-389, 01/21/08 Table of Contents 1.0 Introduction...1 1.1 Unpack...1 1.2 Check Order...1 1.3 Serial Numbers...1

More information

Review of Small Commercial Sensors for Indicative Monitoring of Ambient Gas

Review of Small Commercial Sensors for Indicative Monitoring of Ambient Gas A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 30, 2012 Guest Editor: Renato Del Rosso Copyright 2012, AIDIC Servizi S.r.l., ISBN 978-88-95608-21-1; ISSN 1974-9791 The Italian Association of Chemical

More information

Hydrogen Leak Detection. 9012 XRS system. The complete system for leak detection using hydrogen gas

Hydrogen Leak Detection. 9012 XRS system. The complete system for leak detection using hydrogen gas Hydrogen Leak Detection 9012 XRS system The complete system for leak detection using hydrogen gas Yes, it leaks but where? Telephone cables Gas-filled Petrol stations Gas pipelines power cables Heating

More information

NMC Pro System Manager

NMC Pro System Manager NMC Pro System Manager Maximize the Performance of Your Irrigation System from One Central Location DRIP/MICRO IRRIGATION PRODUCTS Monitor and Control from One Central Location The NMC Pro System Manager

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

2011 European Gas Detection Industry Technology Innovation Award

2011 European Gas Detection Industry Technology Innovation Award 2011 2011 European Gas Detection Industry Technology Innovation Award 2011 Frost & Sullivan 1 We Accelerate Growth Frost & Sullivan s Global Research Platform Frost & Sullivan is in its 50th year in business

More information

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Introduction. Refrigerant Leak Detecting System. Feature and Benefits PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Movita Ceiling Supply Unit Medical Supply Units

Movita Ceiling Supply Unit Medical Supply Units Movita Ceiling Supply Unit Medical Supply Units Featuring a wide range of configurations and options to choose from, the versatile Dräger Movita family gives you enhanced loading capacity together with

More information

UNIVERSAL TRUTHS: EVALUATING NEXT-GENERATION GAS DETECTION

UNIVERSAL TRUTHS: EVALUATING NEXT-GENERATION GAS DETECTION UNIVERSAL TRUTHS: EVALUATING NEXT-GENERATION GAS DETECTION Designing, implementing and maintaining a truly universal approach to gas detection. By Daniel Munson, Byron McLendon Universal Truths: Evaluating

More information

Highly efficient flue gas analyzer

Highly efficient flue gas analyzer Highly efficient flue gas analyzer testo 320 Just a few clicks away from a heating system diagnosis O 2 High-resolution colour graphic display Quick and easy menu structure Storage space for 500 measurement

More information

Operating principle and construction of zirconium dioxide oxygen sensors of the XYA series

Operating principle and construction of zirconium dioxide oxygen sensors of the XYA series 1. PHYSICAL BACKGROUND 1.1 Partial pressure Definition: The partial pressure is defined as the pressure of a single gas component in a mixture of gases. It corresponds to the total pressure which the single

More information

TWO-WIRE TRANSMITTERS FOR ph, ORP, CONDUCTIVITY, OXYGEN, OZONE, AND CHLORINE

TWO-WIRE TRANSMITTERS FOR ph, ORP, CONDUCTIVITY, OXYGEN, OZONE, AND CHLORINE Product Data Sheet 71-5081/rev.K April 2006 Model 5081 TWO-WIRE TRANSMITTERS FOR ph, ORP, CONDUCTIVITY, OXYGEN, OZONE, AND CHLORINE Model 5081 Family of Two-wire Transmitters CHOICE OF COMMUNICATION PROTOCOL:

More information

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration

More information

Selecting Gas Detectors For Confined Space Entry By H. Ross Humphry Canadian Safety Equipment Inc.

Selecting Gas Detectors For Confined Space Entry By H. Ross Humphry Canadian Safety Equipment Inc. Selecting Gas Detectors For Confined Space Entry By H. Ross Humphry Canadian Safety Equipment Inc. When I was first approached to write on article for the IAPA on Gas Detector selection (2500 words no

More information

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure

More information

Hand-held thermometer Model CTH7000

Hand-held thermometer Model CTH7000 Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference

More information

Combustible Gas Safety Monitoring: Infrared vs. Catalytic Gas Detectors

Combustible Gas Safety Monitoring: Infrared vs. Catalytic Gas Detectors Combustible Gas Safety Monitoring: Infrared vs. Catalytic Gas Detectors INTRODUCTION When designing a combustible gas safety monitoring system for oil/gas, petrochemical or other applications, how do you

More information

Honeywell Gas Detection www.honeywellanalytics.com Hendrik Heeze

Honeywell Gas Detection www.honeywellanalytics.com Hendrik Heeze Honeywell Gas Detection www.honeywellanalytics.com Hendrik Heeze GSM: +32 (0)485.80.79.07 hendrik.heeze@honeywell.com Christophe Stas GSM: +32 (0)473.22.36.51 christophe.stas@honeywell.com 24 September

More information