NURSECALL SYSTEMS C-TEC DISABLED PERSONS TOILET ALARM KITS DISABLED PERSONS TOILET ALARMS/SINGLE ZONE CALL SYSTEM KITS

Size: px
Start display at page:

Download "NURSECALL SYSTEMS C-TEC DISABLED PERSONS TOILET ALARM KITS DISABLED PERSONS TOILET ALARMS/SINGLE ZONE CALL SYSTEM KITS"

Transcription

1 NURSECALL SYSTEMS C-TEC DISABLED PERSONS TOILET ALARM KITS DISABLED PERSONS TOILET ALARMS/SINGLE ZONE CALL SYSTEM KITS Include everything required for a reliable and easy to install disabled persons toilet alarm system (except cable and fixings) NC951 Standard disabled persons toilet alarm kit, c/w NC942 call controller, NC807C ceiling pull, NC806CS overdoor light & sounder, NC809DBB reset point & sounder, NC949 disabled wc sticker NC951B Elite disabled persons toilet alarm kit c/w battery back-up c/w NC942B call controller, NC807C ceiling pull, NC806CS overdoor light & sounder, NC809DBB reset point & sounder, NC949 disabled wc sticker NC951/SS Stainless steel disabled persons toilet alarm kit c/w NC941/SS call controller, NC807C plastic ceiling pull, NC806CS/SS s/steel overdoor light & sounder, NC809DB/SS s/steel reset point & sounder, NC949 disabled wc sticker C-TEC 800 SERIES CALL SYSTEM SINGLE ZONE EMERGENCY INDICATOR PANELS C/W 12V PSU NC942 Single zone 140mA call controller c/w psu, reset/mute buttons & relay NC942B Single zone 140mA call controller c/w psu, reset/mute buttons, relay & on-board battery back-up NC941 Single zone 250mA double gang call controller, c/w psu & reset button NC941/SS Single zone 250mA double gang call controller, c/w psu & reset button (s/steel) NC941B Battery back-up kit for NC ZONE EMERGENCY INDICATOR PANELS C/W MUTE & RESET BUTTONS, REQUIRE 12V PSU NC944 Four zone double gang call controller NC930 12V 250mA PSU for up to two NC944s NC925B1 12V 1A PSU for up to three NC944s NC944/SS Four zone double gang call controller (s/steel) NC930/SS 12V 250mA PSU for up to two NC944/SS (s/steel) 10 TO 30 ZONE EMERGENCY INDICATOR PANELS C/W 12V PSU, BATTERY AND MUTE BUTTON NC812KE 10 zone Emergency master panel c/w PSU & battery NC822KE 20 zone Emergency master panel c/w PSU & battery NC832KE 30 zone Emergency master panel c/w PSU & battery Repeater panels and larger master panels available to order 10 TO 30 ZONE STANDARD INDICATOR PANELS C/W 12V PSU Can indicate standard calls only NC810K 10 zone Standard master panel c/w PSU NC820K 20 zone Standard master panel c/w PSU NC830K 30 zone Standard master panel c/w PSU Repeater panels and larger master panels available to order OVERDOOR LIGHTS AND SOUNDERS Can be used to increase call indication levels NC806C Overdoor light NC806C/SS Overdoor light (s/steel version) NC806CS Overdoor light with sounder NC806CS/SS Overdoor light with sounder (s/steel version) NC887D Switchable sounder NC888D Remote sounder STANDARD CALL POINTS, MONITORING POINTS & CEILING PULLS Can generate standard calls only NC802DB Standard call point, button reset c/w remote socket NC802DM Standard call point, magnetic reset c/w remote socket NC807C Ceiling pull unit, no on-board reset, no remote socket NC894DKB Monitoring point, button reset, no remote socket NC894DKM Monitoring point, magnetic reset, no remote socket 50

2 NURSECALL SYSTEMS (continued) EMERGENCY CALL POINTS Can generate standard and emergency calls NC802DEB-1/2 Emergency call point, button reset c/w remote socket NC802DEM Emergency call point, magnetic reset, with remote socket IP65 WATER RESISTANT ALERT POINTS Can be set up to generate standard or emergency calls (not both) NC802DEWM Water resistant master alert point, magnetic reset, no remote socket NC802DEWS Water resistant slave alert point, no on-board reset, no remote socket, max 10 per master NC802DESS IP69K sauna alert point (must be used as a slave to a NC802DEWM) STAINLESS STEEL ALERT CALL POINT Can be set up to generate standard or emergency calls (not both) NC802DEM/SS Stainless steel call point, magnetic reset, no remote socket INFRARED CALL POINTS AND CEILING RECEIVERS Generate standard and/or emergency calls when triggered by a suitable transmitter NC802DERB Infrared call point, button reset c/w remote socket NC802DERM Infrared call point, magnetic reset c/w remote socket NC302RXC Infrared master ceiling receiver, no on-board reset NC302RXCS Infrared slave ceiling receiver, max. 3 per master INFRARED TRANSMITTERS For triggering Infrared call points and ceiling receivers QT412RXA Mk2 transmitter, push/pull for emergency QT412RXCA Mk2 transmitter, push for call/pull for emergency QT424/1 Single way charging unit for NC412 range transmitter QT424/10 Ten way charging unit for NC412 range transmitters RESET POINTS Can be used to reset devices which do not have an on-board reset facility NC809DB Button reset point NC809DM Magnetic reset point NC899IRR Keyswitch reset point, for use with infra-red ceiling receivers NC809DBB Button reset point c/w sounder and braille label MAGNETIC RESET KEYS For use with all magnetic call points, monitoring points and reset points NC803M/10 Pack of 10 magnetic reset keys ANCILLARY CALLING DEVICES Generate standard calls via a call point s remote socket NC805C/6 1.8m (6ft) tail call lead NC805C/14 4.2m (14ft) tail call lead NC805D 1.2 to 3.6m (4 to 12ft) coiled tail call lead NC805P Hand/foot operated pneumatic pad (requires 1 x NC805AS) NC805AS Remote air switch for NC805P NC805MD Portable movement detector MISCELLANEOUS 800 SERIES DEVICES Generate standard calls via a call point s remote socket NC899KD Area isolator, can be used to isolate areas/zones NC884DE Emergency 5:1 input expander, can be used to provide area/zonal indication NC885 Standard 5:1 input expander, can be used to provide area/zonal indication NC889 Call latch module, can trigger a standard call from a n/o or n/c switch NC889ERM Multi-purpose call latch module, can trigger a standard and/or an emergency call from a n/o or n/c switch NC883D 12V relay unit, can be used to switch sirens, strobes, etc NC848/50 50 x anti-tamper screws NC947 Anti-tamper Allen key, for use with anti-tamper screws 51

3 C-CALL CALL/WAITING ROOM SYSTEMS C-TEC C-CALL WAITING ROOM CALL SYSTEM Attractive slimline indicator panels with personalised self-adhesive labels Available in self-resetting or manual reception reset formats Durable desk and wall mounting call pushes with call confirmation LEDs C-CALL SELF-RESETTING DISPLAY PANELS NC905KT 2 zone self-resetting display panel NC906KT 4 zone self-resetting display panel NC907KT 6 zone self-resetting display panel NC925C Double insulated PSU, one required per system Call/Waiting Room Systems C-CALL RECEPTION PANELS NC911K 10 zone reception panel NC921K 20 zone reception panel C-CALL MANUAL RESET RECEPTION PANELS NC912K-5 5 zone resettable reception panel c/w psu NC912K zone resettable reception panel c/w psu NC912K zone resettable reception panel c/w psu C-CALL CALL PUSHES, OVERDOOR LIGHTS AND REMOTE SOUNDERS NC917L Call push (latching or non-latching) NC915L Desk push/4ft lead (latching/non-latching), requires NC NC920 Wall socket, for use with NC915L desk push NC806C Overdoor light NC888D Remote sounder 52

4 ADDRESSABLE CALL SYSTEM C-TEC QUANTEC ADDRESSABLE CALL SYSTEM Multiple call levels - standard call, help required (assist), Full monitoring of all network devices emergency and optional infrared staff attack Staff presence, call accept, manual and automatic call divert facilities Up to 256 network devices per system New optional Quantec Surveyor software allows detailed data Quantec Controller is now programmable via a sophisticated analysis reports to be sent direct to a PCs desktop on criteria such upload/download PC program or by its front panel controls as longest calls, busiest shifts, average call response times, etc. Up to 45 custom place names per system (in addition to an Now with HTM2015 capability (requires specially designed extensive library of pre-loaded place names) third-party switch assemblies used in conjunction with our new Flexible call routing - allows the system to be configured to range of Quantec universal devices) suit a building s exact operational requirements QUANTEC CONTROLLERS, DISPLAYS, SOUNDERS AND OVERDOOR LIGHTS QT601-2 Quantec controller AFP385 Flush bezel for Quantec controller QT707 Quantec PC programming software c/w lead (Windows) NEW SAF m programming lead only NEW QT707S Quantec Surveyor Data Management Software c/w wall socket and lead QT603 Quantec network splitter (installation aid) QT608C Quantec corridor display, with controls QT606 Quantec overdoor light QT606A Quantec addressable overdoor light QT688 Quantec addressable sounder NEW QT688/2 Quantec high-output 82dB addressable sounder (with optional HTM2015 capability - requires QT423 configurator) QUANTEC CALL POINTS, MONITORING POINTS, CEILING PULLS, INFRARED CEILING RECEIVERS AND RADIO RECEIVERS The QT602 call points listed below include remote sockets. Magnetic reset call points & call points without remote sockets are also available QT602 Quantec call point, button reset QT602S Quantec call point, button reset with sounder QT602R Quantec call point, button reset with infrared receiver QT602RS Quantec call point, button reset with sounder & infrared receiver QT602D Quantec slave call point QT607 Quantec ceiling pull unit QT604 Quantec monitoring point, button reset QT302RX Quantec master infrared ceiling receiver QT302RXS Quantec slave infrared ceiling receiver QT422RX Quantec Mk2 radio receiver (compatible with QT412 range transmitters) QT422RXEA Quantec Mk2 radio receiver extension aerial QT421 Single gang monitored heartbeat plate (checks integrity of QT422RX radio receivers) QUANTEC UNIVERSAL DEVICES QT611 Quantec multi-purpose programmable device (unplated), allows third-party switch assemblies & indicators to be interfaced to Quantec NEW QT612 Quantec relay output device (unplated), a zone-specific relay output to trigger third-party strobes, sounders, auto-diallers, etc. NEW QT613 Quantec zonal indicator driver device (unplated), can be used to drive third-party LED indicating devices NEW QT614 Quantec bedhead light dimmer interface (unplated) QT423 Quantec configurator (required to program QT611/612/613/614 devices) QUANTEC DUAL ACTION INFRARED/RADIO TRANSMITTERS Can be used to remotely trigger compatible Quantec infrared receivers and Quantec radio receivers QT412RXA Mk2 Dual action infrared/radio transmitter (Configured for push for attack/pull for attack) QT412RXCA Mk2 Dual action infrared/radio transmitter (Configured for push for call/pull for attack) QT423 Configurator for QT412RXU QT424/1 Single way charging unit for QT412 range dual action transmitter QT424/10 Ten way charging unit for QT412 range dual action transmitters ANCILLARY CALLING DEVICES, PRINTERS AND PAGING EQUIPMENT NC805C/6 1.8m (6ft) tail call lead NC805C/14 4.2m (14ft) tail call lead NC805D m (4-12ft) tail call lead QT600P Quantec printer kit incl. printer, lead & wall socket QT600S Quantec printer/paging wall socket DP874QA 400m Transmitter for alpha pagers, lead & wall socket DP876D Display pager aerial, extends transmitting range to 1500m DP876B Mounting bracket for DP876D DP876F 15 metre low loss cable for DP876D DP877QA 32 character alphanumeric display pager, group A QUANTEC ADDRESSABLE CALL SYSTEM QUANTEC DUAL ACTION TRANSMITTERS Addressable Call System 53

5 2 WIRE DISABLED PERSONS TOILET ALARM DISABLED PERSON TOILET ALARMS VPA-200P Standard Disabled Toilet Kit VPA-220P Premier Disabled Toilet Kit VPA-BB1 Back Up Battery Unit VPA-CB Push Button Call Point VPA-ODI Overdoor Twin LED & Sounder VPA-PC Pullcord VPA-RP Remote Reset Point 54

Intercall 600 & Intercall 700 Installation & Operation Guide Documentation Issue 4.32 www.intercall.co.uk

Intercall 600 & Intercall 700 Installation & Operation Guide Documentation Issue 4.32 www.intercall.co.uk Intercall 600 & Intercall 700 Installation & Operation Guide Documentation Issue 4.32 www.intercall.co.uk No part of this leaflet may be reproduced without prior written consent and while every effort

More information

Quantec Wiring Instructions

Quantec Wiring Instructions Approved Document No. DNUQ777 Rev Quantec Wiring Instructions GENERAL Quantec can be compared to a very sophisticated analogue addressable fire alarm system where the integrity of the wiring is of paramount

More information

Emergency voice communications Product Name

Emergency voice communications Product Name Product Name 76 EATON FIRE AND VOICE ALARM SYSTEMS CFCC2556 January 2015 Contents Contents Emergency voice communications Panels Network exchange units 78 Non network exchange units 80 Devices Outstations

More information

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

Repeaters and Mimics Data Sheet

Repeaters and Mimics Data Sheet Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

CB200W Water Leak Detection Panel Application Guide

CB200W Water Leak Detection Panel Application Guide Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical

More information

Engineer Paging. Staff Paging. Deaf Alert.

Engineer Paging. Staff Paging. Deaf Alert. Engineer Paging. Staff Paging. Deaf Alert. Performance and Quality Whatever you Need Advanced is famous for the quality, performance and ease-of-use of its systems and our products are protecting people

More information

500r+ Installation and User Guide

500r+ Installation and User Guide 500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and

More information

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal O N DS160/DS161 Installation Guide High Performance Request-to-Exit Sensors 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for Request to Exit (REX) interior applications.

More information

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped

More information

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS

More information

Communication A BRITISH MANUFACTURER. Features:

Communication A BRITISH MANUFACTURER. Features: care2 Radial Wired Emergency Voice Communication Manufacturing EVC systems since 2001 CARE2 is a radial wired emergency voice communication system built to the high standard you expect from Baldwin Boxall.

More information

SYSTEM 7000 IRIS+ USER MANUAL

SYSTEM 7000 IRIS+ USER MANUAL SYSTEM 7000 IRIS+ USER MANUAL Table of Contents Section Page No 1. INTRODUCTION... 3 2. THE DISPLAY... 3 3. TRANSMITTERS... 6 4. MESSAGE PAGER SYSTEM... 7 2 1. Introduction 1.1 The IRIS+ is a radio based

More information

Radio Nurse Call Specialists The Choice of the Professionals

Radio Nurse Call Specialists The Choice of the Professionals Customer service Warranty All products manufactured by Medicare are covered for 12 months from date of installation subject to our standard terms and conditions. Service and out of hours Our free technical

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

SERIES ͲΝΒΣΞ ΒΟΘΖ Swann 2013

SERIES ͲΝΒΣΞ ΒΟΘΖ Swann 2013 SERIES Swann 2013 Home Protection that s Advanced & Easy Doorways Windows Garages Sheds Potential Entry Points Blind Spots ALARM SENSOR A typical home layout with suggested mounting points for alarms www.swann.com

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

D200+ Auto-Dialler Installation/Operators Manual

D200+ Auto-Dialler Installation/Operators Manual D200+ Auto-Dialler Installation/Operators Manual Bell System (Telephones) Ltd. Presley Way, Crownhill, Milton Keynes, MK8 0ET D200+ Software Version 1.0 Contents General Description...3 Central Station

More information

QT601-2 QUANTEC CONTROLLER. installation and programming manual Approved Document No. DNU6012001 Rev 4

QT601-2 QUANTEC CONTROLLER. installation and programming manual Approved Document No. DNU6012001 Rev 4 QT601-2 QUANTE ONTROER installation and programming manual Approved Document No. DNU6012001 Rev 4 QT601-2 Quantec ontroller ONTENTS Items Supplied with the Panel...3 Important Notes...3 Summary of New

More information

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions

More information

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS Wireless - Emergency Alert Systems Easy installation - Wireless Radio System no wires or wiring required Evacuation, Alert & Lockdown all in one system S.O.S Assist - up to 6 unique SOS assistance zone

More information

Security Systems Intrusion Alarm

Security Systems Intrusion Alarm Dufferin-Peel Catholic District School Board STANDARD TEXT GUIDELINE FOR Security Systems for SECONDARY AND ELEMENTARY SCHOOLS Prepared by the Plant Department With Assistance from Vision Dynamics Formatted

More information

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual. INTRODUCTION The information provided herein covers the range of products known as the 'Sensor 901' series. The range of equipment is designed to meet the requirements of BS 5839 parts 1 & 4 1988. The

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

Emergency Voice Communication Systems EVCS Network 8 Data Sheet Emergency Voice Communication Systems EVCS Network 8 Data Sheet The Emergency Voice Communications System (EVCS) Network 8 is for use as a Fire Telephone system, Disabled Refuge Call system or as a combined

More information

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

TS510 & TS500. Installation & User Guide. Compatible Equipment

TS510 & TS500. Installation & User Guide. Compatible Equipment Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction

More information

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: eda@electrodetectors.co.uk

More information

Intelligent fire alarm technology at your fingertips

Intelligent fire alarm technology at your fingertips Key ZFP features... 20,000+ event memory (filterable by fire, fault & date) EN54 parts 2 and 4 compliant Non-fire supervisory event functionality Apollo XP95/Discovery protocol Optional thermal printers

More information

Innovative DOOR STATION Solutions

Innovative DOOR STATION Solutions Innovative DOOR STATION Solutions When a visitor arrives at your front door or gate we ring... Your mobile when you are out Your normal telephones in your home Your PABX system in your office Communicating

More information

Alliance System Ordering Guide

Alliance System Ordering Guide Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers

More information

How To Program An Autodialer

How To Program An Autodialer GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE Emergency Response System INSTALLATION & PROGRAMMING GUIDE Copyright micron 2005 Contents Product Description 3 Console Operation Overview 4 Console Wiring Diagram 5 User Manual 6 Transmitter Assembly

More information

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products Basic Security 101 Overview Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products Components of an Alarm System Main Control

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance

More information

conventional system operation

conventional system operation conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than

More information

Fire Detection Product Range

Fire Detection Product Range Fire Detection Product Range World Leading Fire Detection Products from the NITTAN group Issue 1.0 Business Overview The Nittan Group has been at the forefront of the fire protection industry since 1954

More information

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer. Innovative GSM & WIFI dual network operating platform. On WIFI network, the alarm system will work without any fee. If no WIFI, it will work on GSM automatically. With state-of-the-art WIFI network technology,

More information

EQUIPMENT SPECIFICATIONS

EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access

More information

Shunt lock function 3066

Shunt lock function 3066 Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning

More information

Conventional Fire Detection and Extinguishant Control System Specification

Conventional Fire Detection and Extinguishant Control System Specification Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release

More information

Fire alarm system EBL512 G3

Fire alarm system EBL512 G3 Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Generation three G3. Internet: pesn.panasonic.se 2011-03-24 Page 1 of 6 The demands

More information

NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL

NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL NESS D16 16 Zone Control Panel and Dialler OWNER S MANUAL REVISION 2, JULY 2001 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia

More information

Always on the Lookout Perfect Protection against Burglary

Always on the Lookout Perfect Protection against Burglary Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on

More information

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One

More information

Business/Home GSM Alarm System. Installation and User Manual

Business/Home GSM Alarm System. Installation and User Manual Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene

More information

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully. WIRELESS AUTODIAL HOME ALARM SYSTEM AM2000 Instructions for use Important! Please read these instructions carefully. IMPORTANT 1 IDENTIFICATION PLEASE CONTACT BEFORE RETURNING THIS PRODUCT TO THE RETAILER

More information

RACEAIR REMOTE PAGER SYSTEM

RACEAIR REMOTE PAGER SYSTEM Computech Systems, Inc. 301-884-5712 30071 Business Center Dr. Charlotte Hall, MD 20622 RACEAIR REMOTE PAGER SYSTEM TM Introduction: Computech s RaceAir Remote Competition Weather Station with the Data

More information

User Installation Guide

User Installation Guide Careline Alarm User Installation Guide 1.1 IMPORTANT INFORMATION The user s telephone MUST BE connected to the Reach TEL socket - a double adapter on the incoming line must not be used. If the user has

More information

Night Owl 8 Channel DVR with 1TB HDD, HDMI Output, 8 Hi-Resolution Cameras (2 Audio Enabled) and free Night Owl PRO App

Night Owl 8 Channel DVR with 1TB HDD, HDMI Output, 8 Hi-Resolution Cameras (2 Audio Enabled) and free Night Owl PRO App Night Owl 8 Channel DVR with 1TB HDD, HDMI Output, 8 Hi-Resolution Cameras (2 Audio Enabled) and free Night Owl PRO App Night Owl s PRO-881TB is an advanced 8 channel, 8 camera Security System that includes

More information

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

2M IR Mini Dome Quick Installation Guide

2M IR Mini Dome Quick Installation Guide 2M IR Mini Dome 2M IR Mini Dome Quick Installation Guide Please follow the installation steps below to set up 2M IR Mini Dome IP Camera. Check the package contents against the list below. See P.1 Physical

More information

Hills wireless security alarm DIY range

Hills wireless security alarm DIY range Hills wireless security alarm DIY range EASY TO INSTALL DIY system PEACE OF MIND Receive SMS/calls when alarm is armed INTERACTIVE Arm and disarm by SMS or via smartphone app Control your alarm via smart

More information

ERS-2400B. PERS-2400B Personal Emergency Reporting System

ERS-2400B. PERS-2400B Personal Emergency Reporting System PERS-2400B Personal Emergency Reporting System ERS-2400B Durability and Versatility for Emergency Reporting Solutions Create a customized and comprehensive Personal Emergency Reporting System with the

More information

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER Centralizes Monitoring and Alarming for Gas Transmitters and Fire Detectors. The QuadScan II receiver

More information

Alarm Security Kit - NVR

Alarm Security Kit - NVR Alarm Security Kit - NVR EN The alarm configuration menu (see above right screenshot) allows you to configure and change settings for the PIR movement sensors, window/door sensors, remote controls (key

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

$329. Security Systems OPTIONS. (WGUARD) WatchGuard DIY KIT

$329. Security Systems OPTIONS. (WGUARD) WatchGuard DIY KIT Security Systems 65 WatchGuard 8 Do-It It-Yourself Security System Feature packed, this 8 zone "plug & secure" wireless alarm system incorporates the latest supervised wireless technology for your security

More information

GSM COMMUNICATORS CATALOGUE

GSM COMMUNICATORS CATALOGUE COMMUNICATORS CATALOGUE ( ) 870020/B - 07/2007 - Daitem - ATRAL SYSTEM S.A.S. - R.C.S. Grenoble 311 586 382 The services and product data presented in this document may be modified without prior notice

More information

Pancode VoIP/Pantel VoIP Access Control Door Phones. Installation and Programming Manual Release 1.0 June 2006

Pancode VoIP/Pantel VoIP Access Control Door Phones. Installation and Programming Manual Release 1.0 June 2006 Pancode VoIP/Pantel VoIP Access Control Door Phones Installation and Programming Manual Release 1.0 June 2006 Table of Contents 1 Introduction... 2 1.1 Pancode VoIP/Pantel VoIP Kit Contents... 3 2 Physical

More information

System Overview. SpiderAlert. Emergency Signaling System for Correctional Institutions Personal alert signaling always at hand.

System Overview. SpiderAlert. Emergency Signaling System for Correctional Institutions Personal alert signaling always at hand. System Overview Emergency Signaling System for Correctional Institutions Personal alert signaling always at hand Visonetix Emergency Signaling System for Correctional Institutions Personal alert signaling

More information

Residential & Commercial Alarm Systems by Gross Security, LLC

Residential & Commercial Alarm Systems by Gross Security, LLC 151 Main Street, Suite, 1, Get these great features with a landline or cellular alarm system from Gross Security, LLC Alarm system prices include installation Base system includes one hour of training

More information

Safe Health Guarder User Manual

Safe Health Guarder User Manual Safe Health Guarder User Manual Contents Tips: Please read through this user manual before installation so as to operate properly. Please keep well of the user manual for further reference. For properly

More information

PRT3 Printer Module: ASCII Protocol Programming Instructions

PRT3 Printer Module: ASCII Protocol Programming Instructions PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send

More information

4. Do you have a VGA splitter ( Y Cable)? a document camera?

4. Do you have a VGA splitter ( Y Cable)? a document camera? Hooking up your computer to your projector and/or doc camera These instructions will assist you in performing a proper hookup of your computer to your projector and/or document camera. The instructions

More information

WIRELESS HOME ALARM SYSTEM (WHA1)

WIRELESS HOME ALARM SYSTEM (WHA1) WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA 01028. 800-451-7592 / 413-525-7039 (fax) 413-525-8807 http://www.secure-it.

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA 01028. 800-451-7592 / 413-525-7039 (fax) 413-525-8807 http://www.secure-it. PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA 01028 800-451-7592 / 413-525-7039 (fax) 413-525-8807 http://www.secure-it.com IMPORTANT READ ENTIRE MANUAL BEFORE STARTING!!! System Overview

More information

ALARM SYSTEM INSTALLATION GUIDE

ALARM SYSTEM INSTALLATION GUIDE ALARM SYSTEM INSTALLATION GUIDE Congratulations on the purchase of your Egardia alarm system. Egardia's website www.egardia.com Customer services Please visit www.egardia.com if you would like further

More information

Solution Ultima ICP-CC488 Home security you can rely on

Solution Ultima ICP-CC488 Home security you can rely on Solution Ultima ICP-CC488 Home security you can rely on Keeping your home and family safe doesn t need to be complicated. That s why we ve made the Ultima security system so easy to use all it takes is

More information

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems Content Introduction Preventing unauthorized access by perimeter surveillance Monitoring unauthorized access by indoor surveillance

More information

InHome Water Leak Detection Package

InHome Water Leak Detection Package InHome Water Leak Detection Package For Model Numbers ILD10A-L and ILD10A-B Installation Guide / Wiring Diagram For Creating Water Leak Detection-based Events with Line-Powered or Battery-Powered Sensors

More information

Combi B Alarm box. Mounting instructions

Combi B Alarm box. Mounting instructions Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power

More information

ABUS WIRELESS ALARM SYSTEM

ABUS WIRELESS ALARM SYSTEM ABUS WIRELESS ALARM SYSTEM These installation instructions are published by Security-Center GmbH & Co. KG, Linker Kreuthweg 5, D-86444 Affing/Mühlhausen. All rights including translation reserved. Reproductions

More information

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users. BIBUS VOP Advice for use: large blocks of flats with switchboard and mixed mainly audio systems Ideal for door phone systems with up to 250 users VOP technology Easy creation of mixed audio and video door

More information

Omni 600 control panel with 8 zone LED keypad

Omni 600 control panel with 8 zone LED keypad 1 CONTROL PANELS For orders Call: 0860 22 55 23 CONTROL COMMUNICATORS Honeywell Omni & XL Series B0695 B0810 B0669 B0668 B0670 B0682 B0683 B0684 B0678 B0681 KEYPADS Honeywell Omni & XL Series B0685 B0686

More information

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Fire. The Fire Installers Mate. A guide to fire alarm systems design Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

Secure Keypads for access control

Secure Keypads for access control torm Secure Keypads for access control Strike Master Read this manual carefully before attempting to install, program or operate the STORM AXS Strike Master Keypad. After installation the Command Summary

More information

Quick Installation Guide LCD GSM ALARM SYSTEM LH http://www.usmartbuy.com

Quick Installation Guide LCD GSM ALARM SYSTEM LH http://www.usmartbuy.com A. Manipulation Specification Quick Installation Guide 1. Arming Arming means all-around guarded when there is no person at home. All detectors are working. Once something triggers any of the detectors,

More information

Six-defense zone Display Alarm System. User Manual

Six-defense zone Display Alarm System. User Manual Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode

More information

LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets LW-2000-3A Wireless Auto Dial Alarm System Sentry Plus User Manual By Global Gadgets Main Features Simple to use keypad for operation and control. The system can store up to 9 telephone numbers: positions

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10 TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified

More information

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054 WIRELESS ALARM KIT COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS Model Number: IT214054 INSTRUCTION MANUAL Warranty Details/Support This product is warranted against defects for a period of One year if the

More information

Solid as a rock Soliroc

Solid as a rock Soliroc Solid as a rock Soliroc SOLUTIONS FOR EXPOSED OR UNSUPERVISED ENVIRONMENTS Think Soliroc for strength and design in exposed areas at the mercy of vandals and other abuse. The IK 10 Soliroc TM guarantees

More information

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.

More information

WaterCress - Critical Infrastructure Protection

WaterCress - Critical Infrastructure Protection What is? - Critical Infrastructure Protection is a range of water protection technology protecting 80% of the UK s potable drinking water. Our portfolio uses a range of sophisticated sensors to protect

More information

Additional Instruction

Additional Instruction Additional Instruction Note: a. Please connect the camera with 2.4G WIFI router or Ethernet cable, can t support 5G router. b. For first time wifi connection, please put your mobile close to camera within

More information

KNX Lighting Control System

KNX Lighting Control System KNX Lighting Control System Part 1 - Specification Lighting control system A. The following specification details the minimum standards for performance of components, material and operation of lighting

More information

Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4

Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4 TABLE OF CONTENTS A Adjustable Angle Bracket (294/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)... 7 C Coordinator Mounting Bracket (2950 Series)... 7 Concealed Magnetic

More information

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.

More information

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia s largest

More information

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8 ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8 Quick Start A This device is a Z-Wave Actuator. Triple click one of the buttons on the device will include the device.

More information