GSM COMMUNICATORS CATALOGUE
|
|
- Nelson Cobb
- 8 years ago
- Views:
Transcription
1 COMMUNICATORS CATALOGUE ( ) /B - 07/ Daitem - ATRAL SYSTEM S.A.S. - R.C.S. Grenoble The services and product data presented in this document may be modified without prior notice - photos not binding. GM Techtronics Ltd Unit 17 Paxcroft Farm HILPERTON TROWBRIDGE WILTS BA14 6JB Sales Tel: Fax: Technical Support Tel: info@gmtechtronics.co.uk DAITEM ATRAL SYSTEM S.A.S. International development Rue du Pré de l Orme CROLLES Cedex FRANCE Tel + 33 (0) Fax +33 (0) WIRELESS SECURITY SYSTEMS
2 DAITEM COMMUNICATORS ( 2 ) With its range of communicators, Daitem can be relied on for a broad scope of applications A range to cover all applications The new range of Daitem telephone communicators provides reliable and efficient solutions, whatever the type of site on which they are installed. With different product references available, you can choose between a hardwired or radio link depending on your site layout. Whether you opt for a mains-connected solution or an entirely battery-run communicator, the whole range is simple to install thanks to user-friendly and intuitive programming. What s more, you cannot fail to be seduced by the brand new design and compact size of the products, as well as all the accessories available. Find out about the different applications possible with this new range of telephone communicators comprising on-board technology. s boasting genuine independence Daitem telephone communicators use a modem to which trigger inputs are connected by wire or radio in order to transmit alarms or messages from a device (control panel, sensor, etc.) to a remote centre or telephone. They pass on messages about intrusion alarms, technical alarms, etc. to remote users. The communicator can call up several telephone numbers (a remote central station monitoring company or individual correspondents), on a fixed or mobile line. The messages transmitted are either digital (for remote central station monitoring companies), vocal or SMS. It is also possible to call-up the communicator using a fixed or mobile phone in order to remotely control the alarm system or contacts (e.g. for activating an automatic control system). The communicator can be used alone or as backup to a PSTN telephone dialler using a line cut detector (optional). Protection of isolated sites Daitem communicators are not only independent of the PSTN network, but some battery-powered models are also independent of the mains power supply and have a battery life of up to 5 years. Because of this, they are especially suitable for protecting sites that are isolated or under development: houses, construction sites, companies, etc. ( 3 ) Technical monitoring Because the communicators are fully independent, they can also be used for many applications that are entirely unrelated to security. They can be linked to temperature probes, sensors or other technical monitoring devices and thus act as technical call beacons when monitoring of sensitive installations (greenhouses, incubators, etc.) is required. Furthermore, they can come in a sealed casing (optional) to protect them in difficult environments. Different types of messages Voice type messages These messages are used to call up correspondents or keyholders on their fixed or mobile phone. The messages transmitted are either standard or pre-recorded by the user and saved in the communicator memory. The units have several inputs and each can be used for a different personalised message (e.g. Breakdown, freezer, Intrusion, kitchen, Flood, cellar, etc.). SMS type messages These text format messages are used to transmit alarms to mobile phones. Digital type messages These messages are transmitted by the communicator to a remote central station monitoring company. The communicators use Ademco, Contact ID and Daitem protocols. Remote dialogue With their built-in microphone and loudspeaker, Daitem communicators allow users to listen in to the protected premises should an alarm be triggered. To erase any doubt about the alarm, an alarm confirmation call makes dialogue between the person having triggered the alarm and the user possible.
3 APPLICATIONS APPLICATIONS PROTECTING SITES VIA A LINK WITH A HARDWIRED ANTI-INTRUSION ALARM PROTECTING SITES IN AN ENTIRELY INDEPENDENT WAY VIA A LINK WITH A DAITEM ANTI-INTRUSION ALARM Applications possible with a X battery-powered communicator 4 extendible relay inputs/2 outputs. Applications possible with a X battery-powered communicator 4 inputs/2 outputs. linked to a hardwired anti-intrusion alarm in a shop. linked to a Daitem control panel in an isolated dwelling. Daitem control panel linked to a hardwired anti-intrusion alarm in a factory or warehouse as back-up to a PSTN communicator (with line cut detector). Hardwired alarm control panel RTC linked to a Daitem alarm control panel on a mobile construction site. Daitem control panel SENDING A REMOTE TECHNICAL ALARM OPERATING AN AUTOMATIC CONTROL SYSTEM / RECEIVING ALARM NOTIFICATION REMOTELY Applications possible with a X battery-powered communicator 4 extendible relay inputs/2 outputs. Applications possible with a X mains-powered communicator 4 relay inputs/2 outputs. linked to technical sensors in an incubator. linked to an automatic rotation control system on a billboard. Technical sensors Billboard control system linked to technical sensors in a sedimentation tank. linked to a solenoid valve control system. Technical sensors Solenoid valves ( 4 ) ( 5 )
4 COMMUNICATORS FUNCTIONS AND TECHNICAL FEATURES X (version with europeen standard mains plug) U (version with UK mains plug) MAINS-POWERED COMMUNICATOR WITH 4 WIRED INPUTS / 2 RELAY OUTPUTS Recommended for monitoring and controlling technical applications. Mains power supply. Hardwired links with monitored devices. Call back control. Listen-in / talk back. 3 according to Daitem conditions WARRANTY YEARS Powered via external 230 V / 12 V transformer (supplied). Self-monitoring of external power supply and transmission of specific message in case of mains power supply failure. Rechargeable standby battery supplied, 48 hour standby. Consumption in standby mode: 40 ma. Permanent remote control of 2 relay outputs X BATTERY AND/OR MAINS POWERED COMMUNICATOR WITH 4 WIRED INPUTS / 2 RELAY OUTPUTS Powered by (2 x 3,6 V / 18 Ah) lithium battery pack (BatLi23 supplied). Emergency standby battery (3,6 V / 700 mah) lithium/ion (Ref X supplied). Self-monitoring of power supply and transmission of specific message in case of low batteries. Can be powered via 230 V / 12 V external transformer (optional). Remote control of relay outputs: - following alarm confirmation call only if powered by lithium battery pack, - permanently if powered by external mains supply. Recommended for protecting sites via a link with a hardwired anti-intrusion alarm as well as for technical monitoring of sites, without having to rely on the electrical power supply. 5-year llithium battery supply. Hardwired links with monitored devices. Call back control. Listen-in / talk back. 3 according to Daitem conditions WARRANTY in normal conditions of useautonomy 5 YEARS YEARS Consumption in standby mode: 180 µa max. 5-year battery life based on: - 1 test call / week, - 10 events / year. Extension to up to 8 inputs / 4 outputs possible using X board X BATTERY AND/OR MAINS POWERED COMMUNICATOR WITH TwinPass RADIO TRANSMISSION AND 4 WIRED INPUTS / 2 RELAY OUTPUTS Powered by (2 x 3,6 V / 18 Ah) lithium battery pack (BatLi23 supplied). Emergency standby battery (3,6 V / 700 mah) lithium/ion (Ref X supplied). Self-monitoring of power supply and transmission of specific message in case of low batteries. Can be powered via 230 V / 12 V external transformer (optional). Remote control of relay outputs and Daitem alarm system: - following alarm confirmation call only if powered by lithium battery pack, - permanently if powered by external mains supply. Recommended for protecting sites fitted with a Daitem anti-intrusion alarm. 5-year battery power supply. Hardwired links with monitored devices. Transmission of radio messages from a Daitem alarm system. Call back control. Listen-in / talk back. 3 according to Daitem conditions WARRANTY in normal conditions of useautonomy 5 YEARS YEARS TwinPass failsafe radio transmission Consumption in standby mode: 180 µa max. 5-year battery life based on: - 1 test call / week, - 10 events / year. Compatible with all Daitem alarm ranges. ( 6 ) ( 7 )
5 COMMUNICATORS COMMON FUNCTIONS Programming: Programming protected by access code. Simple and intuitive programming using keypad and LCD screen. Programming possible by PC via RS232 series connection. Programming saved in communicator memory and on SIM card. Parameter settings can be copied to other communicators using SIM card. Voice synthesis and messages pre-registered in 6 languages (F, GB, I, E, D, NL). Welcome and alarm voice messages can be personalised. Transmission of voice and/or SMS messages. Transmission of digital messages (Ademco, Contact ID and Daitem protocols). Selectable delay in transmitting alarm messages (0, 20, 40, 90 seconds), and immediate transmission of confirmed intrusion alarms. Call numbers: Directory of 9 call numbers defined by the user: - 5 numbers for each relay input (activation and deactivation of each input), - 2 numbers for test call cycle (test call, Daitem radio alarm system arming/disarming), - 5 numbers for communicator monitoring (anti-tamper system, power low, etc.) and for alarms sent from a Daitem alarm system. Call cycle renewed 5 times, with acknowledgement and termination possible during cycle. Listen-in function and alarm confirmation call can be programmed separately for each number. Call numbers comprising up to 20 digits max. Remote control: Can be programmed separately for each number and each communicator following an alarm confirmation call. Permanent access for products with an external power supply. Commands possible: - communicator relay output command, - telephone number change, - listen-in and talk-back (speak-out), - status of communicator inputs, - control of Daitem alarm system (arm/disarm, system status, last alarm) using X communicator, - control of one or two Daitem radio receivers using X model. Function protected by access code. COMMON TECHNICAL FEATURES Inputs: 4 dry contact type, programmable inputs: - normally open (NO) or normally closed (NC), - input type (sensor, telephone line cut detector, arm/disarm validation), - filtering time before programmable call. Extension to up to 8 inputs possible using X board for X model. Outputs: 2 dry contact type, programmable outputs: - switch or timer mode (can be programmed from 1 sec. to 10 hours). Extension to up to 4 outputs possible using X board for X model. Built-in microphone and loudspeaker for: - recording personalised messages (10 sec. for welcome message + 3 sec. for each message associated with an input), - remote listen-in to premises, - remote talk-back or speak-out. Programming keypad with 16 keys (mobile phone type). LCD screen with back-lighting. antenna built-in to communicator with additional input for external antenna. SUBSCRIPTIONS AND NETWORK ACCESS Daitem communicators include a module requiring the user to subscribe to a mobile telephone operator. SIM card not supplied. The operator should be chosen locally to ensure the best transmission conditions. Quad-band Modem. Power supply: - 3,6 V / 700 mah lithium-ion battery (supplied), recharged via transformer or lithium battery pack (supplied), - consumption during calls: 500 ma, - consumption in standby mode: 180 µa (lithium pack) or 40 ma (external power supply), - battery life before recharging: 1 to 3 days. Monitoring of power supply status and transmission of message in case of power failure. Anti-tamper protection against opening and removal. Events memory: 100. Built-in programming and use of communicator in 6 languages: French, Italian, German, Spanish, English and Dutch*. Automatic summer / winter daylight saving time change for programmed cyclic status calls. Degree of protection: IP 30. Operating temperature: -10 C to + 55 C. Dimensions (W x H x D): 253 x 195 x 53 mm. Weight: 695 g (without battery). It is up to the user to make sure their contract with the chosen service company is valid. Specific precautions: Daitem shall not be held liable for any problems with communicator calls reaching their destination due to the unavailability of the mobile phone network. ( 8 ) ( 9 )
6 ACCESSORIES X EXTENSION BOARD 4 INPUTS / 2 OUTPUTS X PROTECTIVE CASING ACCESSORIES Increases the number of inputs and outputs (only applies to X communicator). Casing to be used when installing the communicator in dusty environments X (version with europeen standard mains plug) U (version with UK mains plug) 230 V / 9 V DC MAINS SUPPLY X PROGRAMMING KIT Transformer to power communicator via mains (compatible with battery and mainspowered models) X 5 DB ANTENNA ON BRACKET Software and serial link cable for programming the communicator via a computer. Software available in 6 languages: French, Italian, German, Spanish, English and Dutch X LITHIUM-ION BATTERY Improves the quality of the signal reception for locations where the signal is weak. 3,6 V / 700 mah X MAGNETIC 3 DB EXTERNAL ANTENNA BatLi23 LITHIUM PACK Improves the quality of the signal reception for locations where the signal is weak X PSTN TELEPHONE LINE CUT DETECTOR 2 x 3,6 V / 18 Ah X SERIAL-USB ADAPTER Linked to the communicator and PSTN line, it detects any cut in the telephone line lasting longer than 2 min. Requires 12 V power supply (not provided). ( 10 ) Serial-USB adapter enabling the programming software to be used on computers fitted only with USB ports and no serial ports. ( 11 )
S100. GSM House Alarm System. Http://www.GSMalarmsystem.com
S100 GSM House Alarm System Http://www.GSMalarmsystem.com 1. Brief introduction The GSM Alarm System is a new security protection solution special for home, house and office and other applications. It
More informationGSM Voice Auto Dialer & SMS Sender JC-999
GSM Voice Auto Dialer & SMS Sender JC-999 Main features: () Large LCD display,integrated integrated keypad, human-friendly programming; (2) Support 2 alarm receiving numbers; (3) Triggering means: N.C
More informationESPACE ALARM( ) Peace of mind is yours W I R E L E S S S E C U R I T Y S Y S T E M S
ESPACE ALARM( ) Peace of mind is yours W I R E L E S S S E C U R I T Y S Y S T E M S Peace of mind... for your family, all day every day You want protection for your family and your property. It s a question
More informationGSM ALARM SYSTEM USER MANUAL
GSM ALARM SYSTEM USER MANUAL 1. Instruction The alarm system is based on GSM network. With a GSM SIM card, it can be used wherever you want and no need to connect any wire, which is convenient and easy
More informationAlways on the Lookout Perfect Protection against Burglary
Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on
More informationFirmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
More informationFLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS
FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS
More informationHow To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
More informationEmergency Dialer DIAL-ALERT MODEL: AD-105. www.skylinkhome.com
www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: AD-105 If you would like to order Skylink s products or have difficulty getting them to work or download information and user manual, please :
More informationBURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
More informationFrequency selective monitoring and logging of environmental electromagnetic fields
FREQUENCY SELECTIVE EMF AREA MONITOR AMS-8060 Frequency selective monitoring and logging of environmental electromagnetic fields Up to 20 fully programmable frequency bands Real built-in spectrum analyser
More informationGSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual
Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150 User Manual Ver
More informationBusiness/ Home GSM Alarm System
Business/ Home GSM Alarm System BUSINESS/HOME GSM ALARM SYSTEM POWER STATUS RECORD SIGNAL User Manual Profile For a better understanding of this product, please read this user manual thoroughly before
More informationSTATUS POWER MONITOR ALARM SOS DISARM
STATUS POWER MONITOR ALARM SOS DISARM I. Features II. Preparation before use III. Host 1.LED status explanation 2. Host panel IV. System Settings 1. Coding of wireless sensors 2. Exit coding 3. Settings
More informationOverview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
More informationSECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
More informationIntruder Alarm System
Intruder Alarm System GSM & PSTN Wireless and Wired Touch Model 2013-01 V1.0.0 Statment This equipment must be installed and used in strict accordance with the instructions given in this user documentation.
More informationUsers Manual of GSM Home Alarm System with Photo-taken
GSM-IV REMOTE CAMERA MANNAL The Excellent GSM + Camera alarm system bases on the GSM network, integrates the communication technology, can automatic screen a photo with the intruder or burglar, and send
More informationSMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
More informationBusiness/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
More informationMemcom Emergency Telephone
Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming
More informationNESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL
NESS D16 16 Zone Control Panel and Dialler OWNER S MANUAL REVISION 2, JULY 2001 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia
More informationGSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
More informationGSM INTRUSION ALARM SYSTEM INSTRUCTION MANUAL. GSM - PSTN - SMS - TOUCH GSM Wireless Security Alarm System
GSM INTRUSION ALARM SYSTEM INSTRUCTION MANUAL GSM - PSTN - SMS - TOUCH GSM Wireless Security Alarm System SECURE YOUR HOME AND BUSINESS Printed in Shenzhen RE: G60-GSM-August-2013 Key Features Smart touch
More informationAPPLICATION SUPPORT BULLETIN
Equipment SENSAPHONE required for typical SCADA 3000 SCADA remote site using 3000 a cellular telephone APPLICATION SUPPORT BULLETIN : Equipment requirements for a typical Sensaphone SCADA 3000 remote site
More informationIntelligent GSM Auto-Dial Alarm System
Auto-dial Alarm System Intelligent GSM Auto-Dial Alarm System Profile For a better understanding of this product, please read this user manual thoroughly before using it. 2013.2.V1.0 Auto-dial Alarm System
More informationAC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
More informationGSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.
More informationMOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction Alarm Host Diagram
More informationAlarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since 1997. automated production systems
Alarm Systems Agri-Alert alarms have been protecting swine operations across the world since 1997. Peace of Mind The Agri-Alert alarm system constantly monitors your operation and quickly notifies you
More informationWireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)
CN2HK LIMITED Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) User Manual Please read this manual before operating this product. After you finish reading this manual,
More informationWIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
More informationICP-CC488. Installation Guide ICP-CC488 Control Panel
ICP-CC488 EN Installation Guide ICP-CC488 Control Panel ICP-CC488 Installation Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems,
More informationQuectel M72 Development Board
Quectel M95GSM/GPRS Module Quad Band Module supporting 850/900/1800/1900 MHz. Supports GPRS Multi-slot Class 12 with max of 85.6 kbps( uplink & downlink) speeds. Fax support with specs of Group 3, Class
More informationTwo-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.
Innovative GSM & WIFI dual network operating platform. On WIFI network, the alarm system will work without any fee. If no WIFI, it will work on GSM automatically. With state-of-the-art WIFI network technology,
More informationHills wireless security alarm DIY range
Hills wireless security alarm DIY range EASY TO INSTALL DIY system PEACE OF MIND Receive SMS/calls when alarm is armed INTERACTIVE Arm and disarm by SMS or via smartphone app Control your alarm via smart
More informationEM8610 e-alarm GSM Alarm System Starter Kit
EM8610 e-alarm GSM Alarm System Starter Kit 2 ENGLISH EM8610 - GSM Alarm system Starter Kit Table of contents 1.0 Introduction... 4 1.1 Packing contents... 4 2.0 Explanation of the control panel... 5 2.1
More informationAutomatic Telephone Dialer TD-101(W)
Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages
More informationCompact Rugged Design. 300 Memory Channels. Single Head Remote Option. 6 Programmable Function Keys. Enhanced Kenwood Audio. 100W Transmit Power*
HF TRANSCEIVER Compact Rugged Design 300 Memory Channels Single Head Remote Option 6 Programmable Function Keys Enhanced Kenwood Audio 100W Transmit Power* High-stability TCXO Enhanced Security Features
More informationPowerCode Wireless. Fully supervised wireless system. Features
PowerCode Wireless WIRELESS Fully supervised wireless system Features technology Fully supervised Attractive, elegant design Reporting of tamper and RF signal jamming Transmitter inactivity and low battery
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationAWARDS AND CERTIFICATIONS:
ABOUT ELDES ELDES is an electronic engineering and design company, specializing in residential and business alarm, monitoring, control and automation systems. ELDES vision is CONNECTED PROTECTED COMFORT:
More informationOUR PROFESSIONALISM IS THE BEST YOU CAN FINE IN THE MARKET AFRICAN HOME GROWN SAFETY AND SECURITY SOLUTION [CCTV SECURITY CLINIC 4U]
[CCTV SECURITY CLINIC 4U] OUR PROFESSIONALISM IS THE BEST YOU CAN FINE IN THE MARKET AFRICAN HOME GROWN SAFETY & SECURITY SOLUTIONS CCTV Upgrading, Services, Support and Security Auditing, Due Diligence
More informationUser Manual GSM Alarm System. www.deltasecurity.cn. All rights reserved by Delta Security Co., Ltd
User Manual GSM Alarm System All rights reserved by Delta Security Co., Ltd Dear Clients, Thank you for using our GSM Alarm System. We are committed to giving you the best home security available today
More informationWITURA CORPORATION SDN BHD
WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:
More informationPROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.
WIRELESS AUTODIAL HOME ALARM SYSTEM AM2000 Instructions for use Important! Please read these instructions carefully. IMPORTANT 1 IDENTIFICATION PLEASE CONTACT BEFORE RETURNING THIS PRODUCT TO THE RETAILER
More informationGSM House Alarm System. S110 User Manual. Ver 1.00 Date Issued: 2010-09-01
GSM House Alarm System S110 User Manual Ver 1.00 Date Issued: 2010-09-01 All rights reserved by King Pigeon Hi-Tech. Co., Ltd. Website: Http://www.GSMalarmsystem.com Table of Contents 1. Brief introduction
More informationHCO BG30L Mobile (GSM) Surveillance Camera/Alarm System. User s Manual
HCO BG30L Mobile (GSM) Surveillance Camera/Alarm System User s Manual Content 1 Product Information... 2 1.1 General Description....2 1.2 Interfaces... 2 1.3 Information Display... 3 1.4 Features... 4
More informationUnited Security Products Automatic Dialers are a NEW BREED of Security
Auto Voice Dialers United Security Products Automatic Dialers are a NEW BREED of Security Communications and Notification equipment for the Security Professional. Small, Compact and User Friendly. USP
More informationTX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
More informationWaterproof portable tracker and
Catalog for GPS tracking system Model Description Picture Mainstream GPS/GSM/GPRS vehicle tracking device, designed as solution for fleet management, which is a GP4000 robust fleet tracking device not
More informationProduct Information S N O. Portable VIP protection CCTV & Alarm System 2
Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to
More information$329. Security Systems OPTIONS. (WGUARD) WatchGuard DIY KIT
Security Systems 65 WatchGuard 8 Do-It It-Yourself Security System Feature packed, this 8 zone "plug & secure" wireless alarm system incorporates the latest supervised wireless technology for your security
More informationMonitoring,Telemaintenance,... HACCP. Innovative Supermarket solutions. Tecnologia ed Evoluzione
Monitoring,Telemaintenance,... HACCP Innovative Supermarket solutions Tecnologia ed Evoluzione For more compact systems, with the same management and control needs as larger areas, PlantWatch offers the
More informationWIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
More informationNew GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.
New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter
More informationGSM AD05 Slave GSM Auto Dialer- Instruction Manual
GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second
More informationRAD-SYS-NEMA4X-SMS Control Cabinet. Solution guide for SMS-based remote access control and intrusion detection system
Solution guide for SMS-based remote access control and intrusion detection system Contents Application: Remote access control and intrusion detection Page 1 Solution: SMS Relay control cabinet Page 2 System
More informationHomeSafe Security Panel User s Guide 5400 Series
HomeSafe Security Panel User s Guide 5400 Series CONTENTS Features... 4 Introduction... 5 Keypad... 6 Keypad Indicators... 7 OPERATION by KEYPAD... 8 Arming... 9 Disarming... 10 Resetting Alarms... 10
More informationGPS Vehicle and personal location tracker. User manual
GPS Vehicle and personal location tracker User manual 1 Contents 1. Product overview... 2 2. Safety instruction... 3 3. Specification and parameters... 3 4. Getting started... 4 4.1 Hardware and accessories...
More informationElvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by
Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by providing quality, innovative products and solutions to the
More informationSpectra SP Expandable Security Systems
Spectra SP Expandable Security Systems Control Panels Feature Comparison between Spectra SP Control Panels Feature SP4000 SP65 SP5500 SP6000 SP7000 StayD Maximum Zones 32 32* 32* 32* 32* On-board Zones
More informationIDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited
(Rev. 1.0) China Aerospace Telecommunications Limited Contents 1. Introduction......3 2. Specifications...4 2.1 External Interface... 4 2.2 Status Indicator...... 5 2.3 Technical Parameters... 6 3. Device
More informationⅡ Function Characteristics
CONTENT Ⅰ Introduction... 2 Ⅱ Function Characteristics... 2 Ⅲ Technical Parameters... 3 Ⅳ Packet List... 4 Ⅴ Components... 4 Ⅵ Installation and Connection...4 Ⅶ The Description of Basic Operations... 5
More informationA RF18 Remote control receiver MODULE
A RF18 Remote control receiver MODULE User Guide No part of this document may be reproduced or transmitted (in electronic or paper version, photocopy) without Adeunis RF consent. This document is subject
More informationM400gsm GSM Modem Datasheet
M400gsm GSM Modem Datasheet >> Product Introduction The M400g GSM Modem is a modem for SMS or voice, providing RS232/RS485/USB port option. The M400g is an easy to install productivity tool designed to
More informationNJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)
Safely into a new day Advanced modular FIRE ALARM CONTROL PANEL with additional functionality NJP-400A NJP-401A I m on FIRE (Bruce Springsteen) EN 54-2, EN 54-4 Cert No. 1124a DESCRIPTION OP-400A, NJP-400A,
More informationDC-8706K Auto Dial Alarm System
DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power
More informationBusiness/Home GSM Alarm systems. Installation and User Manual
Business/Home GSM Alarm systems Installation and User Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Business/Home GSM alarm system
More informationVTS. Vehicle Tracking Systems
VTS Vehicle Tracking Systems TSU INDEX Vehicle Tracking Systems Ref Number Description 1 7301 Vehicle Tracking System with Magnet Base 2 7302 GPS Vehicle Tracking System 3 7303 Vehicle Tracking Management
More informationPower-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
More informationWireless Alarm system s manual
MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1/11/2011 1. Before You Begin For your safety and the safety of others, and to ensure that you get the most
More informationIphone & Android App Smart GSM Home Alarm System
Iphone & Android App Smart GSM Home Alarm System PST-GA242Q User Guide Version V14.3 Dear User, Thanks for selecting the intelligent alarm system. Please read through this guide before installation so
More informationHome Security Alarm System
Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better
More informationGSM/3G UMTS/GPS/SMS Data Logger. The King Pigeon S262W S263W Data Logger inbuilt industrial GSM and 3G WCDMA
S262W S263W GSM/3G UMTS/GPS/SMS Data Logger The King Pigeon S262W S263W Data Logger inbuilt industrial GSM and 3G WCDMA module, GPS optional. channel Analog inputs (0-20mA,-20mA,0-5V) support Ultra-Low/Low/High/Ultra-High
More informationMSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments
The MSITel module family allows your ground console to be everywhere while balloon experiments run everywhere MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments
More informationSecurity Kit / Security Kit Plus - S4 Cell + Line GSM and Landline Alarm System
Security Kit / Security Kit Plus - S4 Cell + Line GSM and Landline Alarm System www.etiger.com Features - GSM/PSTN transmitter - Supports up to 30 remote controls, 50 wireless accessories and 50 RFID tags
More informationContinuous, remote monitoring and logging of electromagnetic fields
MULTI-BAND EMF AREA MONITOR AMB-8057 Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total emf values Magnetic fields monitoring from
More information500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
More informationBusiness/Home. GSM Alarm system
Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900
More informationDual-Network LCD Keyboard Intelligent Alarm. User Guide
Dual-Network LCD Keyboard Intelligent Alarm User Guide Ver 2.0 Version 2.0 Page 1 of 38 Table of Content 1. Introduction... 3 1.1 General Description... 3 1.2 System Features... 3 2. Anatomy of the LCD
More informationTemperature & Humidity SMS Alert Controller
Smart Energy Control... Temperature & Humidity SMS Alert Controller Energy Saving, Environment & Proper es Protec on 2 temperature sensors or 1 x temperature & 1 x humidity sensor Keep track of temperature
More informationwireless alarm system reliable protection for small-size buildings
wireless alarm system reliable protection for small-size buildings The MICRA system is an ideal solution wherever you need a simple and reliable alarm system with GSM communicator. The MICRA system has
More informationSolution-16 Operators Manual ISSUE 1.60
Solution-16 Operators Manual ISSUE 1.60 !"#$%&"'()*+ Operators Manual Copyright 2002 by, SYDNEY, AUSTRALIA Document Part Number MA880O DOCUMENT ISSUE 1.60 Printed 22 March 2002 This documentation is provided
More informationSix-defense zone Display Alarm System. User Manual
Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode
More informationLLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER
LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER System for flow measurement, data acquisition and transmission for wastewater with long battery life With Long Life Battery Open Channel Flow Meter
More informationD24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST
D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia s largest
More informationAdemco Vista-20P/First Alert FA-168C Basic Commands
Zones 64 total Ademco Vista-20P/First Alert FA-168C Basic Commands Wireless Yes, Zones 09 to 48 + 16 Keyfob Zones (Zones 49 to 64) Batteries Downloadable Partitions 2 12 volt Rechargable inside main Panel,
More informationMONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts
MONITORING A m 3 /s C Rh V J m/s F g/m 3 Pa kw Measurement Sensors Dry contacts Logging Analysis, Alarms Various products XML/HTTP SNMP, E-mail GPRS/SMS Reports Graphs, Excel Alarms www.hw-group.com Measurement,
More informationGilsson AlwaysFind Web Base Fleet Management AVL & Personal GPS Trackers
Gilsson AlwaysFind Web Base Fleet Management AVL & Personal GPS Trackers System block diagram AlwaysFind GSM/GPRS network GPS Tracking Systems AlwaysFind OR AlwaysFind Mini Web Base control center Internet
More informationTable of Contents. System Requirement of MP3 Player:... 4. Connection and Downloading... 7. Downloading DRM10 Files... 8.
Table of Contents Instructions... 1 Precautions... 2 System requirements... 4 System Requirement of MP3 Player:... 4 Introduction... 5 Features... 5 Charging the Battery... 6 Connection and Downloading...
More informationController 5000GL Controller 5000GL provides flexible system architecture with options of GBUS and LOCAL BUS communications to field devices, to meet a wide range of site requirements. GGBUS L LOCAL BUS
More informationFT-1000/GPS-N. System of remote monitoring and control of physical
FT-1000/GPS-N System of remote monitoring and control of physical Localization of vehicles during transport by sending the values of temperature, RH%, etc.. with relative alarm threshold is exceeded. Send
More informationContinuous, remote monitoring and logging of electromagnetic fields
MULTI-BAND EMF AREA MONITOR AMB-8057-03/G Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total EMF values Electric field monitoring
More informationAPI Marine. BMS Presentation. Ballast Measurement Systems
API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter
More informationWireless Auto-dial Intruder Alarm System
Wireless Auto-dial Intruder Alarm System User Manual User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Features and Function 1.
More information868 Mhz. Wirefree DIY. Friendly. Easy Fit Range of Alarms
DIY Friendly Easy Fit Range of Alarms 60% of burglaries attempted on UK homes fitted with burglar alarms are unsuccessful. Introducing the new Easy Fit range of alarms With decades of experience in residential
More informationAuto Dialer. Manual E-921APQ E-921GPQ
Troubleshooting: Auto dialer will not arm/disarm Auto dialer will not dial out Unit doesn t respond to a call-back Difficulty in activating room monitor by telephone remote control Make sure that you have
More informationLW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets
LW-2000-3A Wireless Auto Dial Alarm System Sentry Plus User Manual By Global Gadgets Main Features Simple to use keypad for operation and control. The system can store up to 9 telephone numbers: positions
More informationSuperGuard VT-05 Vehicle Tracking Device
SuperGuard VT-05 Vehicle Tracking Device The SuperGuard VT-05 Vehicle Tracker is a professional GPS tracking device designed for fleet management and commercial data centers, with customizable data upload
More information