8000C Digital Panoramic and Cephalometric System. User s Guide
|
|
|
- Joan Lamb
- 9 years ago
- Views:
Transcription
1 8000C Digital Panoramic and Cephalometric System User s Guide
2 Notice Congratulations on your purchase of the KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System. The KODAK 8000C unit is the KODAK 8000 equipped with the cephalostat unit. Thank you for your confidence in our products and we will do all in our power to ensure your complete satisfaction. The User Guide for the KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System includes information on the cephalometric features. For the panoramic features, see the KODAK 8000 Extraoral Imaging System (SM722) User Guide. We recommend that you thoroughly familiarize yourself with this Guide in order to make the most effective use of your system. WARNING: We recommend that you consult the Safety, Regulatory and the Technical Specification User Guide before using the KODAK 8000C Extraoral Imaging Systems. The information contained in this Guide may be subject to modification without notice, justification or notification to the persons concerned. No part of this Guide may be reproduced without the express permission of Carestream Health, Inc. The US Federal law restricts this device to sale by or on the order of a physician. This document is originally written in English. Manual Name: KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide Part Number: SM735 Revision Number: 02 Print Date: 03/2010 The brand names and logos reproduced in this Guide are copyright. KODAK is a trademark of KODAK used under License. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System, complies with Directive 93/42/CEE relating to medical equipment Manufacturer Carestream Health, Inc. 150 Verona Street Rochester NY Authorized Representative in the European Community EC REP TROPHY 4, Rue F. Pelloutier, Croissy-Beaubourg Marne la Vallée Cedex 2, France
3 Contents 1 About This Guide Conventions in this Guide KODAK 8000C UNIT OVERVIEW General Overview Mobile Components General Functional Components Digital Sensor Locations Laser Locations Control Panel X-Ray Remote Control Overview Positioning Accessories and Replacement Parts IMAGING SOFTWARE OVERVIEW Computer System Requirements General Software Overview KODAK Dental Imaging Software Cephalometric Acquisition Interface Module Cephalometric Acquisition Interface Module Cephalometric Acquisition Window Overview Cephalometric Program Pane Cephalometric Patient Pane Cephalometric Parameter Pane GETTING STARTED Switching on the Unit Starting the Imaging Software Creating a Patient Record Accessing the Cephalometric Acquisition Window ACQUIRING CEPHALOMETRIC IMAGES Acquiring a Lateral Image Preparing the Unit and Setting the Acquisition Parameters Acquiring a Frontal AP or PA Image Preparing the Unit and Setting the Acquisition Parameters Preparing and Positioning the Patient Acquiring an Oblique Image Preparing the Unit and Setting the Acquisition Parameters Preparing and Positioning the Patient Acquiring a Submento-Vertex Image Preparing the Unit and Setting the Acquisition Parameters Preparing and Positioning the Patient KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed 02 iii
4 Contents Acquiring a Carpus Image Preparing the Unit and Setting the Acquisition Parameters Preparing and Positioning the Patient X-Ray Dose Emission Information MAINTENANCE Daily Monthly Annually TROUBLESHOOTING Quick Troubleshooting iv
5 Chapter 1 About This Guide Conventions in this Guide The following special messages emphasize information or indicate potential risk to personnel or equipment: WARNING Warns you to avoid injury to yourself or others by following the safety instructions precisely. CAUTION Alerts you to a condition that might cause serious damage. IMPORTANT Alerts you to a condition that might cause problems. NOTE Emphasizes important information. TIP Provides extra information and hints. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
6 Conventions in this Guide 1 2 About This Guide
7 Chapter 2 KODAK 8000C UNIT OVERVIEW The KODAK 8000C digital panoramic and cephalometric unit is designed to carry out the following radiological examinations: Panoramic Maxillary Sinus Temporomandibular Joints (TMJ) Lateral cephalometric Frontal (PA or AP) cephalometric Oblique cephalometric Submento-vertex cephalometric Carpus cephalometric General Overview The KODAK 8000C digital panoramic and cephalometric unit is composed of the following functional components: The unit head that contains all the electronic control The rotative arm The fixed arm with a control panel The panoramic digital sensor The x-ray source assembly The x-ray remote control The chin rest and bite block The chin rest base The panoramic chin rest and bite block The temple supports The hand grips The cephalostat arm The cephalostat head The head clamps and ear cones The nasion support The acquisition software (see Imaging Software Overview ) The following figures illustrate the general overview of the KODAK 8000C digital panoramic and cephalometric units. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
8 General Overview IMPORTANT The Cephalostat can be positioned either on the right or the left side of the KODAK 8000 unit. Mobile Components Figure 2-1 illustrates the up and down movement of the KODAK 8000C digital panoramic and cephalometric units mobile component and the rotation of the rotative arm. Figure 2 1 KODAK 8000 and KODAK 8000C Units Mobile Components 2 2 KODAK 8000C UNIT OVERVIEW
9 General Overview General Functional Components Figure 2-2 illustrates the general functional components of the KODAK 8000C digital panoramic and cephalometric units. Figure 2 2 KODAK 8000 and KODAK 8000C Units Functional Components ON/OFF button 10 Collimator selector 2 Chin rest and bite block 11 Unit rotative arm 3 Temple supports 12 X-Ray remote control 4 Temple supports control knob 13 PC hosting the imaging and the acquisition software 5 Hand Grips 14 Cephalostat arm 6 Control panel 15 Cephalostat head 7 Height adjustment buttons 16 Head clamps and ear cones 8 Panoramic digital sensor 17 Nasion support 9 X-Ray source assembly KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
10 General Overview Digital Sensor Locations Figure 2-3 illustrates the locations of the digital panoramic and digital cephalometric sensors of the KODAK 8000C digital panoramic and cephalometric units. Figure 2 3 KODAK 8000 and KODAK 8000C Units Digital Sensor Locations system 2 4 KODAK 8000C UNIT OVERVIEW
11 General Overview Laser Locations Figure 2-4 illustrates the location of the lasers of the KODAK 8000C digital panoramic and cephalometric units. Figure 2 4 KODAK 8000 and KODAK 8000C Units Laser Beam Locations Mid-sagittal plane positioning laser beam 2 Frankfort plane positioning laser beam 3 Canine plane positioning laser beam 4 Cephalometric Frankfort plane positioning laser beam KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
12 Control Panel Control Panel The control panel is an alphanumeric, digital soft touch console. It allows the operator to control certain unit functions. It also displays the operating parameters and error messages. Figure 2 5 Unit Control Panel 8 Digital Panoramic and Cephalometric System kv ma S X-Ray emission LED: Yellow, indicates the x-rays are being emitted. 2 Display Screen: Displays the current acquisition parameters and the error messages. 3 Reset button: Resets the unit arm to the initial position to enable the patient to enter and exit the unit. 4 Laser beam button: Activates the laser positioning beams to correctly position the patient. 2 6 KODAK 8000C UNIT OVERVIEW
13 X-Ray Remote Control Overview X-Ray Remote Control Overview The x- ray remote control enables you to launch a radiological image acquisition via the exposure button from outside the x-ray room. You must press and hold the exposure button until the end of acquisition. Premature release of the exposure button interrupts the acquisition. Figure 2 6 X-Ray Remote Control 1 1 Exposure button: launches image acquisition. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
14 Positioning Accessories and Replacement Parts Positioning Accessories and Replacement Parts The following accessories are used when positioning a patient. They are delivered with the KODAK 8000 digital panoramic and KODAK 8000C digital panoramic and cephalometric unit. Table 2-1 and Table 2-2 list the panoramic and cephalometric positioning accessories. Table 2 1 Panoramic Positioning Accessories and Replacement Parts Accessory Description Panoramic chin rest and TMJ x2 Maxillary sinus chin rest TMJ x2 and TMJ x4 nose rest Standard bite block Bite block for edentulous patients A set of right and left temple supports x2 Single use sheaths for bite blocks (500 pcs box) 2 8 KODAK 8000C UNIT OVERVIEW
15 Positioning Accessories and Replacement Parts Table 2 2 Cephalometric Positioning Accessories and Replacement Parts Accessory Description Head clamps with ear cones x2 Nasion support KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
16 Positioning Accessories and Replacement Parts 2 10 KODAK 8000C UNIT OVERVIEW
17 Chapter 3 IMAGING SOFTWARE OVERVIEW Computer System Requirements This section specifies the minimum computer system requirements for KODAK 8000C digital panoramic and cephalometric extraoral imaging system software. IMPORTANT It is MANDATORY to check that the computer system configuration is compatible with the computer system requirements for the KODAK 8000C software. If necessary you MUST update your computer system configuration. KODAK 8000C MUST be connected to the computer via a point-to-point Ethernet link and not via a LAN. DO NOT place the computer and the peripheral equipment connected to it in the immediate vicinity of the patient in the unit. Leave at least 1.5 m distance from the unit. The computer and the peripheral equipment must conform to the IEC standard. Table 3 1 Minimum Computer System Requirements Item Viewing Acquisition Comments CPU 2 GHz Intel Duo Core 2 GHz Intel Duo Core RAM 2 GB 2GB RAM has a major impact on system performance. Hard disk drive 1.2 GB for software installation 80 GB free space to use the software 1.2 GB for software installation Graphic board Nvidia / ATI based board supporting Open GL 1.2 with 256 MB of video RAM on AGP x8 video bus (for example: Nvidia GeForce 6800 GT) Nvidia / ATI based board supporting Open Glide 1.2 with 256 MB of video RAM on AGP x8 video bus (for example: Nvidia GeForce 6800 GT) The video RAM has major impact on system performance. Monitor 1 monitor 17" or larger 1024 x 768 minimum screen resolution - 32 bits color mode Operating system (32 bits) Windows 2000 SP4 Windows XP Home / Pro edition SP2 Windows Vista 1 monitor 17" 1280 x 880 minimum screen resolution Windows XP Home / Pro edition SP2 Windows Vista Your monitor is a vital component in displaying quality images. Low-quality screens will prevent you from proper diagnoses and treatment. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
18 General Software Overview Table 3 1 Minimum Computer System Requirements (Continued) Item Viewing Acquisition Comments Ethernet interface 1 Ethernet interface 1 Ethernet interfaces (100Mbits) If there is a LAN connection a second Ethernet interface is required. CD/DVD drive A DVD-BURNER drive is required. A DVD-BURNER drive is required. Backup Media Removable/portable, external hard disk drive Removable/portable, external hard disk drive. We strongly recommend a daily backup of x-ray images and patient records. General Software Overview The KODAK 8000C digital panoramic and cephalometric extraoral imaging system operates with the following software: KODAK dental imaging software Cephalometric acquisition interface module KODAK Dental Imaging Software The KODAK dental imaging software is a user-friendly working interface that was designed and developed specifically for radiological diagnosis. It is the common imaging platform for all our digital systems for dentistry. The KODAK dental imaging software has the following features: Patient record management using Patient Window features Extraoral and intraoral image management using Imaging Window features NOTE For a complete information on the KODAK Dental Imaging Software, see the KODAK Dental Imaging Software, Quick Start Guide. Cephalometric Acquisition Interface Module The cephalometric acquisition interface module is a user-friendly working interface that was designed and developed specifically for KODAK 8000C digital panoramic and cepahlometric extraoral imaging system. 3 2 IMAGING SOFTWARE OVERVIEW
19 Cephalometric Acquisition Interface Module Cephalometric Acquisition Interface Module Cephalometric Acquisition Window Overview The Cephalometric Acquisition Window is the main cephalometric interface with the KODAK 8000C cephalometric extraoral imaging system that provides you with imaging acquisition functions. Figure 3 1 Cephalometric Acquisition Window 1 Information button: About: Identifies the Software and the Firmware versions Reset of the Values: Resets to the manufacturing parameter settings Memorize settings: Memorizes the user preference settings for each patient type (kv, ma and seconds) 2 Preview Screen: Displays the acquired image in real time. 3 Selected Parameter Display: Displays the current acquisition parameter settings. 4 System Status Screen: Displays various alert or warning messages originating from the unit. 5 X-Rays ON / OFF button: Turns off the x-ray emissions to demonstrate the acquisition process for the patient. 6 Generator Cooling indicator: Indicates the automatic cooling time (mm:ss) required for the generator to reach 0 for a new acquisition. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
20 Cephalometric Acquisition Interface Module 7 Positioning laser button: Activates the laser positionning beams to correctly position the patient. 8 Reset button: Resets the rotative arm in the start position. 9 Ready Indicator LED Green indicates the unit is ready to start acquisition. Black indicates the unit is not ready to start acquisition. 10 Exit button: Closes the Acquisition Window. 11 X-Ray Emission indicator: Yellow, indicates the x-ray emission status. 12 Selector Button: Selects different acquisition setting options. Click Program to select examination type options. Click Patient to select patient type parameters. Click Parameters to select exposure parameter options. The Selector button enables you to access the following 3 panes: Program pane: Examination type options Patient pane: Patient type parameter options Parameters pane: Exposure parameter options 3 4 IMAGING SOFTWARE OVERVIEW
21 Cephalometric Acquisition Interface Module Cephalometric Program Pane The cephalometric Program pane enables you to choose different radiological exams as well as different acquisition formats. Figure 3 2 Cephalometric Program Pane Radiological exam options: Click for a lateral exam. Click for a submento-vertex exam. Click or for a frontal exam (AP and PA). Click for a carpus exam. Click for an oblique exam. NOTE The above list of exam types are only a sample of exam options of the Program pane. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
22 Cephalometric Acquisition Interface Module Cephalometric Patient Pane The cephalometric Patient pane enables you to choose different patient parameters. The selection of the patient parameters influences the quality of the image. The selected parameters must be based on the patient age and morphology. Figure 3 3 Cephalometric Patient Pane 1 Patient type parameters: Click if the patient is a child. Click if the patient is adult. 2 Patient size parameters: Click if the patient is small. Click if the patient is medium. Click if the patient is large. 3 6 IMAGING SOFTWARE OVERVIEW
23 Cephalometric Acquisition Interface Module Cephalometric Parameter Pane The cephalometric Parameter pane enables you to choose exposure parameters for the radiological image acquisition. If the default parameter setting is not adapted to your patient type, you can manually adapt the parameter settings to the patient type and save this setting as the default setting. Figure 3 4 Cephalometric Parameter Pane 1 Radiation dose options: kv: Kilovolt ma: Milliampere S: Second 2 Fine-tuning buttons: Click to fine-tune the kv, ma and the second. 3 Saving parameter button: Click to save the selected parameters. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
24 Cephalometric Acquisition Interface Module 3 8 IMAGING SOFTWARE OVERVIEW
25 Chapter 4 GETTING STARTED Switching on the Unit Before switching on the unit, check that: The installation of the unit is complete. The PC is switched on. IMPORTANT You must switch on the PC and wait for it to be ready for the connection before switching on the unit. To switch on the unit, follow these steps: 1. On the unit column, press the ON button. 2. You must wait for a minute for the connection between the unit and the PC to be established. If you start the imaging software before the connection is established an error message is displayed. Click OK, close the imaging software and wait for the connection to be established. 3. You can now proceed to start the imaging software. IMPORTANT To increase the operating life of the x-ray tube, if the unit has not been used for a month, you must follow the following procedures before use. 1. In the Panoramic Acquisition Window, select the Parameter pane. 2. Select the following series of parameter settings: 70 kv ma 80 kv - 10 ma 85 kv - 10 ma 3. Leave the x-ray room and close the door. For each parameter setting, from the x-ray remote control, press and hold the button to launch the x-ray The unit is now ready to be used for acquisition. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
26 Starting the Imaging Software Starting the Imaging Software To start the imaging software, follow these steps: 1. On your desktop, double-click. OR From your PC, click Start > All Programs > Kodak > Kodak Dental Software. A blank Patient Window is displayed. 2. Create or open an existing patient record. Creating a Patient Record To create a patient record, follow these steps: 1. In the Patient Window, from the toolbar, click OR From the menu bar, select Patient > New. 2. Enter the required patient information. The Last name, the First name and the Date of birth fields are required. 3. From the menu bar, select Picture > Insert Picture to add a *.tif or *.bmp picture of the patient to the record. Select the picture from your directory and click Open. 4. Click OK to save. The patient record is automatically assigned a 7-digit number starting with a letter (for example, M ). 5. Click to access the Imaging Window. 6. Select an image acquisition. 4 2 GETTING STARTED
27 Accessing the Cephalometric Acquisition Window Accessing the Cephalometric Acquisition Window To access the Acquisition Windows, follow these steps: 1. In the Imaging Window, from the toolbar, click to access the Cephalometric Acquisition Window. 2. Prepare the acquisition parameters and launch an acquisition. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
28 Accessing the Cephalometric Acquisition Window 4 4 GETTING STARTED
29 Chapter 5 ACQUIRING CEPHALOMETRIC IMAGES Acquiring a Lateral Image Before acquiring a lateral image, check that you have: Reset the unit rotative arm to the start position for patient to enter the unit. Selected the patient record. Accessed the Imaging Window. Accessed the Cephalometric Acquisition Window. Preparing the Unit and Setting the Acquisition Parameters To set the acquisition parameters, follow these steps: 1. Raise and block the sensor manually. 2. On the x-ray source assembly, set the collimator selector to LA. 3. Position the head clamps manually for the lateral exam. IMPORTANT You must position the head clamps manually because they are not positioned automatically from the Program pane exam type selection. In this case, the relevant exam type selection icon becomes active. 4. In the Cephalometric Acquisition Window, click the Program button to access the Program pane. In the Program pane the for a lateral exam is active. 5. Click the Patient button to access the Patient pane. Select the patient: Type Size 6. If the default parameter setting is not adapted to your patient type, click the Parameter button and in the Parameter pane select the appropriate parameters. To save the new parameter settings as the default settings, click Memorize settings. fand select 7. Preparing and Positioning the Patient To prepare and position the patient, follow these steps: KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
30 Acquiring a Lateral Image 1. Ask the patient to remove all metal objects. 2. Ask the patient to wear a lead apron. Ensure that the apron lays flat across the patient s shoulders. 3. Press and hold the height adjustment buttons to raise the cephalostat head. 4. Open the head clamps and ask the patient to stand up straight, in front of the cephalometric unit, in the appropriate position. 5. Press and hold the height adjustment buttons to level the ear cones to the patient s auditory canals. 6. Insert gently one cone in the auditory canal of the patient. Turn gently the button to close the arms. Insert gently the second cone in the auditory canal of the patient. 7. On the control panel, click to turn ON the Frankfort laser positioning beam. Align the patient with the Frankfort laser beam. 5 2 ACQUIRING CEPHALOMETRIC IMAGES
31 Acquiring a Lateral Image 8. Lower the nasion support to a vertical position. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
32 Acquiring a Lateral Image Launching the X-ray To launch the x-ray, follow these steps: 1. Leave the x-ray room and close the door. You must keep visual contact with the patient during acquisition. IMPORTANT To stop the acquisition, if any problem, release the exposure button of the remote control or press the red emergency stop button. 2. Launch the x-ray with the remote control. Press and hold the exposure button until the end of acquisition. The turns yellow, indicating x-ray emission. The image appears on the Preview Screen of the Cephalometric Acquisition Window. When the acquisition ends, the Cephalometric Acquisition Window disappears and the acquired image is transferred automatically to the Imaging Window. 3. Check the image quality, if satisfactory, remove the ear cones and the nasion support and release the patient. 5 4 ACQUIRING CEPHALOMETRIC IMAGES
33 Acquiring a Frontal AP or PA Image Acquiring a Frontal AP or PA Image Before acquiring a frontal AP or PA image, check that you have: Reset the unit rotative arm to the start position for patient to enter the unit. Selected the patient record. Accessed the Imaging Window. Accessed the Cephalometric Acquisition Window. Preparing the Unit and Setting the Acquisition Parameters To acquire a frontal AP or PA image, follow these steps: 1. Raise and block the sensor manually. 2. On the x-ray source assembly, set the collimator selector to AP/PA. 3. Position the head clamps manually for the frontal AP or PA exam. IMPORTANT You must position the head clamps manually because they are not positioned automatically from the Program pane exam type selection. In this case, the relevant exam type selection icon becomes active. 4. In the Cephalometric Acquisition Window, click the Program button to access the Program pane. In the Program pane, click for a frontal PA exam. 5. Click the Patient button to access the Patient pane. Select the patient: Type Size 6. If the default parameter setting is not adapted to your patient type, click the Parameter button and in the Parameter pane select the appropriate parameters. To save the new parameter settings as the default settings, click Memorize settings. fand select KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
34 Acquiring a Frontal AP or PA Image Preparing and Positioning the Patient To prepare and position the patient, follow these steps: 1. Ask the patient to remove all metal objects. 2. Ask the patient to wear a lead apron. Ensure that the apron lays flat across the patient s shoulders. 3. Press and hold the height adjustment buttons to raise the cephalostat head. 4. Open and position the head clamps parallel to the cephalometric sensor. Ask the patient to stand up straight in front of the cephalometric unit in the following positions: For a frontal AP, facing the generator For a frontal PA, facing the cephalometric sensor 5. Press and hold the height adjustment buttons to level the ear cones to the patient s auditory canals. 6. Insert gently one cone in the auditory canal of the patient. Turn gently the button to close the arms. Insert gently the second cone in the auditory canal of the patient. 7. On the control panel, click to turn on the Frankfort laser positioning beam. Align the patient with the Frankfort laser beam for the frontal AP only. Figure 5 1 Frontal AP Figure 5 2 Frontal PA 5 6 ACQUIRING CEPHALOMETRIC IMAGES
35 Acquiring a Frontal AP or PA Image Figure 5 3 Frontal AP Figure 5 4 Frontal PA Launching the X-ray To launch the x-ray, follow these steps: 1. Leave the x-ray room and close the door. You must keep visual contact with the patient during acquisition. IMPORTANT To stop the acquisition, if any problem, release the exposure button of the remote control or press the red emergency stop button. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
36 Acquiring a Frontal AP or PA Image Figure 5 5 Frontal AP Figure 5 6 Frontal PA 2. Launch the x-ray with the remote control. Press and hold the exposure button until the end of acquisition. The turns yellow indicating x-ray emission. The image appears on the Preview Screen of the Cephalometric Acquisition Window. When the acquisition ends, the Cephalometric Acquisition Window disappears and the acquired image is automatically transferred to the Imaging Window. 3. Check the image quality. If satisfactory, remove the ear cones and release the patient. 5 8 ACQUIRING CEPHALOMETRIC IMAGES
37 Acquiring an Oblique Image Acquiring an Oblique Image Before acquiring an oblique image, check that you have: Reset the unit rotative arm to the start position for patient to enter the unit. Selected the patient record. Accessed the Imaging Window. Accessed the Cephalometric Acquisition Window. Preparing the Unit and Setting the Acquisition Parameters To acquire an oblique image, follow these steps: 1. Raise and block the sensor manually. 2. On the x-ray source assembly, set the collimator selector to AP/PA. 3. Position the head clamps manually for the oblique exam with the desired angle. IMPORTANT You must position the head clamps manually because they are not positioned automatically from the Program pane exam type selection. In this case, the relevant exam type selection icon becomes active. 4. In the Cephalometric Acquisition Window, click the Program button to access the Program pane. In the Program pane: The for an oblique exam is active. Click to select the desired angle. 5. Click the Patient button to access the Patient pane. Select the patient type. 6. Click the Patient button to access the Patient pane. Select the patient: Type Size 7. If the default parameter setting is not adapted to your patient type, click the Parameter button and in the Parameter pane select the appropriate parameters. To save the new parameter settings as the default settings, click Memorize settings. fand select KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
38 Acquiring an Oblique Image Preparing and Positioning the Patient To prepare and position the patient, follow these steps: 1. Ask the patient to remove all metal objects. 2. Ask the patient to wear a lead apron. Ensure that the apron lays flat across the patient s shoulders. 3. Press and hold the height adjustment buttons to raise the cephalostat head. 4. Open the head clamps and ask the patient to stand up straight in front of the cephalometric unit, in the appropriate position. 5. Press and hold the height adjustment buttons to level the ear cones to the patient s auditory canals. 6. Insert gently one cone in the auditory canal of the patient. Turn gently the button to close the arms. Insert gently the second cone in the auditory canal of the patient. 7. Lower the nasion support to a vertical position ACQUIRING CEPHALOMETRIC IMAGES
39 Acquiring an Oblique Image Launching the X-ray To launch the x-ray, follow these steps: 1. Leave the x-ray room and close the door. You must keep visual contact with the patient during acquisition. IMPORTANT To stop the acquisition, if any problem, release the exposure button of the remote control or press the red emergency stop button. 2. Launch the x-ray with the remote control. Press and hold the exposure button until the end of acquisition. The turns yellow indicating x-ray emission. The image appears on the Preview Screen of the Cephalometric Acquisition Window. When the acquisition ends, the Cephalometric Acquisition Window disappears and the acquired image is automatically transferred to the Imaging Window. 3. Check the image quality. If satisfactory, remove the ear cones and the nasion support. Release the patient. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
40 Acquiring a Submento-Vertex Image Acquiring a Submento-Vertex Image Before acquiring a submento-vertex image, check that you have: Reset the unit rotative arm to the start position for patient to enter the unit. Selected the patient record. Accessed the Imaging Window. Accessed the Cephalometric Acquisition Window. Preparing the Unit and Setting the Acquisition Parameters To acquire a submento-vertex image, follow these steps: 1. Raise and block the sensor manually. 2. On the x-ray source assembly, set the collimator selector to AP/PA. 3. Position the head clamps manually for a frontal AP exam.. IMPORTANT You must position the head clamps manually because they are not positioned automatically from the Program pane exam type selection. In this case, the relevant exam type selection icon becomes active. 4. In the Cephalometric Acquisition Window, click the Program button to access the Program pane. In the Program pane, click for a submento-vertex exam. 5. Click the Patient button to access the Patient pane. Select the patient: Type Size 6. If the default parameter setting is not adapted to your patient type, click the Parameter button and in the Parameter pane select the appropriate parameters. To save the new parameter settings as the default settings, click Memorize settings. fand select 5 12 ACQUIRING CEPHALOMETRIC IMAGES
41 Acquiring a Submento-Vertex Image Preparing and Positioning the Patient To prepare and position the patient, follow these steps: 1. Ask the patient to remove all metal objects. 2. Ask the patient to wear a lead apron. Ensure that the apron lays flat across the patient s shoulders. 3. Press and hold the height adjustment buttons to raise the cephalostat head. 4. Open the head clamps and ask the patient to stand up straight in front of the cephalometric unit, in the appropriate position. 5. Press and hold the height adjustment buttons to level the ear cones to the patient s auditory canals. 6. Insert gently one cone in the auditory canal of the patient. Turn gently the button to close the arms. Insert gently the second cone in the auditory canal of the patient. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
42 Acquiring a Submento-Vertex Image Launching the X-ray To launch the x-ray, follow these steps: 1. Leave the x-ray room and close the door. You must keep visual contact with the patient during acquisition. IMPORTANT To stop the acquisition, if any problem, release the exposure button of the remote control or press the red emergency stop button ACQUIRING CEPHALOMETRIC IMAGES
43 Acquiring a Submento-Vertex Image 2. Launch the x-ray with the remote control. Press and hold the exposure button until the end of acquisition. The turns yellow indicating x-ray emission. The image appears on the Preview Screen of the Cephalometric Acquisition Window. When the acquisition ends, the Cephalometric Acquisition Window disappears and the acquired image is automatically transferred to the Imaging Window. 3. Check the image quality. If satisfactory, remove the ear cones and release the patient. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
44 Acquiring a Carpus Image Acquiring a Carpus Image Before acquiring a carpus image, check that you have: Reset the unit rotative arm to the start position for patient to enter the unit. Selected the patient record. Accessed the Imaging Window. Accessed the Cephalometric Acquisition Window. Preparing the Unit and Setting the Acquisition Parameters To acquire a carpus image, follow these steps: 1. Raise and block the sensor manually. 2. On the x-ray source assembly, set the collimator selector to AP/PA. 3. Position the head clamps manually for a frontal AP exam. IMPORTANT You must position the head clamps manually because they are not positioned automatically from the Program pane exam type selection. In this case, the relevant exam type selection icon becomes active. 4. In the Cephalometric Acquisition Window, click the Program button to access the Program pane. In the Program pane, click for a carpus exam. 5. Click the Patient button to access the Patient pane. Select the patient: Type Size 6. If the default parameter setting is not adapted to your patient type, click the Parameter button and in the Parameter pane select the appropriate parameters. To save the new parameter settings as the default settings, click Memorize settings. fand select 5 16 ACQUIRING CEPHALOMETRIC IMAGES
45 Acquiring a Carpus Image Preparing and Positioning the Patient To prepare and position the patient, follow these steps: 1. Ask the patient to remove all metal objects. 2. Ask the patient to wear a lead apron. Ensure that the apron lays flat across the patient s shoulders. 3. Press and hold the height adjustment buttons to raise the cephalostat head. 4. Ask the patient to stand on the side of the cephalometric unit, open the hand fully and place it on the sensor. WARNING Make sure that the patient is not positioned in front of the x-ray emission. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
46 Acquiring a Carpus Image Launching the X-ray To launch the x-ray, follow these steps: 1. Leave the x-ray room and close the door. You must keep visual contact with the patient during acquisition. IMPORTANT To stop the acquisition, if any problem, release the exposure button of the remote control or press the red emergency stop button. 2. Launch the x-ray with the remote control. Press and hold the exposure button until the end of acquisition. The turns yellow indicating x-ray emission. The image appears on the Preview Screen of the Cephalometric Acquisition Window. When the acquisition ends, the Cephalometric Acquisition Window disappears and the acquired image is automatically transferred to the Imaging Window. 3. Check the image quality, if satisfactory, then release the patient ACQUIRING CEPHALOMETRIC IMAGES
47 X-Ray Dose Emission Information X-Ray Dose Emission Information Compliance with EURATOM 97/43 Directive You can right-click on each image to display the estimated emitted dose received by the patient. You can use this information to calculate the effective dose received by the patient for the image. The radiation emission dose is expressed in mgy.cm2. This dose is measured at the primary collimator outlet. The dose is accurate to +/-30%. The primary slot is 0.5 mm wide and 18.2 mm high. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
48 X-Ray Dose Emission Information 5 20 ACQUIRING CEPHALOMETRIC IMAGES
49 Chapter 6 MAINTENANCE This section describes the maintenance tasks that you need to perform regularly for your KODAK 8000C unit and the accessories. WARNING Switch off the unit, then, clean all accessible parts of the machine with an alcohol-based non-corrosive product. Avoid using liquids inside the unit. Follow the alcohol-based product manufacturer recommendations for safety precautions. Daily Carry out the following maintenance tasks: CAUTION You can use the usual disinfectant products, but we recommend that you protect the unit from contamination by using barriers available from dental distributors. Follow the disinfectant product manufacturer recommendations for safety precautions. Table 6 1 Daily Maintenance Tasks Accessories Head clamps and ear cones Nasion support All components that come into contact with the patient and the operator Outer covers of the unit Maintenance Tasks Clean with medical-grade 76% alcohol disinfectant before the next patient is x-rayed. Clean all components with medical-grade 76% alcohol disinfectant before the next patient is x-rayed. Wipe the unit with a dry cloth at the end of each day's operation. Monthly Wipe the outer covers of the unit with a soft, dry cloth. Annually WARNING Do not use detergents or solvents to clean the outer covers of the unit. We recommend a general inspection of the unit carried out by an authorized service technician. KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
50 Annually 6 2 MAINTENANCE
51 Chapter 7 TROUBLESHOOTING Quick Troubleshooting Occasionally, malfunctions can occur during use in the event of an incorrect action. An information (I) error code is displayed on the Display Screen of the unit Control Panel and the message is displayed on the popup on the Acquisition Window System Status Screen. In some cases, an audible warning is also issued. The following table lists the information messages, their description and the action to take: IMPORTANT If an E message is displayed, the malfunction persists or more serious conditions occur, contact a qualified technician. When you call the qualified technician have the following information ready: Model Number: KODAK 8000C Error Code Number: E xx Message displayed on the popup on the Acquisition Window. Table 7 1 Information Messages Information Error Code Information Message Description Action I 1 X-Ray tube cooling Cooling in progress. Wait until the Generator Cooling Indicator on the Acquisition Window reaches zero. I 2 Thermal security Cooling in progress. Wait until the Generator Cooling Indicator on the Acquisition Window reaches zero. I 3 Release handswitch The acquisition has ended. Release the exposure button of the x-ray remote control. I 4 Ceph sensor position The cephalometric sensor position does not match the selected radiological program. I 5 Head clamps position The head clamps position does not match the selected exam program. I 6 Wrong rotative arm position The exposure button of the x-ray remote control is inactive because the rotative arm is not in the start position. Position correctly the sensor for: LA, for lateral position AP/PA, for all the other radiologica programs Position manually the head clamps for the selected exam. Press position. to reset the rotative arm in start KODAK 8000C Digital Panoramic and Cephalometric Extraoral Imaging System User Guide (SM735)_Ed
52 Quick Troubleshooting Table 7 1 Information Messages (Continued) Information Error Code Information Message Description Action I 7 Raise sensor The panoramic sensor is incorrectly positioned. I 8 Lower sensor The panoramic sensor is incorrectly positioned. I 9 Cooling Ceph sensor The Cephalometric sensor is in the cooling process. I 10 Collimator position The collimator is not correctly positioned or does not match the radiological program selection. I 13 Mains too low There is a problem with the mains current input. I 14 Mains too high There is a problem with the mains current input. I 15 Interface inactive The Acquisition Window cannot be accessed. Check that the panoramic sensor is fully retracted and locked in the upper position. Check that the panoramic sensor is fully retracted and locked in the lower position. Wait until the Ready Indicator LED is green. Reposition the collimator. Call a qualified technician. Call a qualified technician. 1. Check that the unit is switched on. 2. Wait for the connection between the unit and the PC. 3. Check that the Acquisition Window is not masked by another application, in this case close the masking application. 7 2 TROUBLESHOOTING
53 8000C 8000C System Trophy A Subsidiary of Carestream Health, Inc. 4 rue F. Pelloutier Croissy-Beaubourg Marne la Vallée Cedex 2 (France) Carestream Health, Inc., The Kodak trademark and trade dress are used under license from Kodak. User s Guide For more information, visit: SM735 Ed02 03/2010 Digital Panoramic and Cephalometric System User s Guide Guide d Utilisation Benutzerhandbuch Gebruikershandleiding Guida d Uso Guiá del Usuario Guia de Utilizaçao
I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit
I-Max Touch Range PAN / CEPH / 3D digital panoramic unit Evolutive 3 in 1 panoramic unit 3D A new dimension for a complete diagnosis I-Max Touch 3D Evolutive, simple, fast The panoramic unit realizes complete
Progeny Vantage Panoramic X-ray System
Progeny Vantage Panoramic X-ray System User Guide For Vantage units manufactured during or after October 2012 0120 Part Number: 00-02-1607 REV. H ECN: P3244 Contents Contents... 2 1 Regulatory Information...
WARNING: We recommend that you consult the Safety, Regulatory and Technical Specification User Guide before using the CS 2200.
CS 2200 User Guide Notice Congratulations on your purchase of the CS 2200. Thank you for your confidence in our products and we will do all in our power to ensure your complete satisfaction. The User Guide
USER AND INSTALLATION MANUAL
Revision 1 - October 2013 User and installation manual O-link The manufacturer OWANDY reserves the right to make modifications to its products or to their specifications in order to improve the performance,
Podium View TM 2.0 Visual Presenter Image Software User Manual - English (WINDOWS)
Podium View TM 2.0 Visual Presenter Image Software User Manual - English (WINDOWS) Table of Contents 1. Introduction... 2 2. System Requirements... 2 3. Installing Podium View... 3 4. Connection to the
Hardware Guide for the Classic and Elite CR Systems. 2011-08-04 PN 9G9637 Version 1.0
Hardware Guide for the Classic and Elite CR Systems 2011-08-04 PN 9G9637 Version 1.0 Use of the Content Carestream Health CR Systems are designed to meet international safety and performance standards.
Essential points for X-ray technicians
Essential points for X-ray technicians Planmeca USA From: Michelle Bottino Planmeca X-ray Specialist Procedures for taking a ProMax Panoramic Exposure Set up computer to acquire image in the software.
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
Installation Guide v1.11 and Higher
Progeny Imaging Installation Guide v1.11 and Higher 00-02-1604 Rev. D ECN P3483 Revision Date: 6/2/2015 0120 Contents 1. About This Manual... 3 Text Conventions... 3 2. Welcome to Progeny Imaging... 4
ActiView. Visual Presenter Image Software User Manual - English
ActiView Visual Presenter Image Software User Manual - English Date: 05/02/2013 Table of Contents 1. Introduction... 3 2. System Requirements... 3 3. Install ActiView - Windows OS... 4 4. Install ActiView
How To Run A Factory I/O On A Microsoft Gpu 2.5 (Sdk) On A Computer Or Microsoft Powerbook 2.3 (Powerpoint) On An Android Computer Or Macbook 2 (Powerstation) On
User Guide November 19, 2014 Contents 3 Welcome 3 What Is FACTORY I/O 3 How Does It Work 4 I/O Drivers: Connecting To External Technologies 5 System Requirements 6 Run Mode And Edit Mode 7 Controls 8 Cameras
RVG 6500 System. User & Installation Guide
RVG 6500 System User & Installation Guide Notice The User & Installation Guide for the RVG 6500 System includes information on the installation of the device as well as its usage. We recommend that you
Central Management System
Central Management System Software Installation Guide Ver. 1.5.0.101115.001 ... ii System Introduction... 3 Client/Server Architecture...3 System Requirements... 4 System Setup...4 Multiple Monitor Configuration...5
Monitor Wall 4.0. Installation and Operating Manual
Monitor Wall 4.0 en Installation and Operating Manual Monitor Wall 4.0 Table of Contents en 3 Table of Contents 1 Introduction 4 1.1 About this Manual 4 1.2 Conventions in this Manual 4 1.3 Minimum Installation
AXIS Camera Station Quick Installation Guide
AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
Contents. Hardware Configuration... 27 Uninstalling Shortcuts Black...29
Contents Getting Started...1 Check your Computer meets the Minimum Requirements... 1 Ensure your Computer is Running in Normal Sized Fonts... 7 Ensure your Regional Settings are Correct... 9 Reboot your
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
ACS CLIENT SOFTWARE USER MANUAL
ACS CLIENT SOFTWARE USER MANUAL 1 ACS USER GUIDE 1.1 System Requirement Recommended System Requirement OS CPU VGA RAM HDD WindowXP, Vista Pentium 4, 2Ghz 1024*768, 64MB 24bit color graphic card 1GB 20MB
CMS-DH CENTRAL MANAGEMENT SOFTWARE
CMS-DH CENTRAL MANAGEMENT SOFTWARE CMS-DH is a central management software that allows you to view and manage up to 300 DH200 series DVRs. System Requirements Your system must meet the system requirements
================================================================== CONTENTS ==================================================================
Disney Epic Mickey 2 : The Power of Two Read Me File ( Disney) Thank you for purchasing Disney Epic Mickey 2 : The Power of Two. This readme file contains last minute information that did not make it into
13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES
LESSON 13 Managing Devices OBJECTIVES After completing this lesson, you will be able to: 1. Open System Properties. 2. Use Device Manager. 3. Understand hardware profiles. 4. Set performance options. Estimated
Magic Wand Portable Scanner
Magic Wand Portable Scanner PDS-ST470-VP User Manual Table of Contents 1. Key Features... 3 2. Functional Parts... 3 3. Explanation of the Status Icons... 5 4. Using the Scanner... 5 4.1. Charging up the
How To Install A Basler Aviator Gige Camera
Basler aviator QUICK INSTALLATION GUIDE FOR GigE CAMERAS Document Number: AW000977 Version: 02 Language: 000 (English) Release Date: 15 June 2011 Preliminary The information in this document is preliminary
7. Computer System Minimum Requirement. 31 8. Troubleshooting. 32. PortableCapture Pro Software Introductions...33
Table of Contents EN 1. Precaution. 3 2. Preparation..6 Standard Accessories 6 Part Names & Functions..7 3. key features..... 8 4. Use the Microscope.....9 Install Battery... 9 Insert a MicroSD Card...
EasyMP Monitor Operation Guide Ver.4.40
EasyMP Monitor Operation Guide Ver.4.40 2 Notations Used in This Guide The following table shows the symbols used in this manual, along with descriptions of what they mean. Caution q s Indicates procedures
AW-HE60 Firmware Upgrade Procedure
AW-HE60 Firmware Upgrade Procedure Please be sure to read this first. AW-HE60 Upgrade Procedure February 2015 The update of AW-HE60 camera is performed via a network from Web setting screen on
USB 2.0 VGA ADAPTER USER MANUAL
USB 2.0 VGA ADAPTER USER MANUAL CONTENTS INTRODUCTION... 3 FEATURES... 3 SYSTEM REQUIREMENTS... 3 PACKAGE CONTENTS... 3 SUPPORTED COMMON DISPLAY RESOLUTION... 4 TECHNICAL SPECIFICATIONS... 4 INSTALLATION
Load Bulletin ADP, Inc. Dealer Services 1950 Hassell Road Hoffman Estates, IL 60169-6308
Load Bulletin ADP, Inc. Dealer Services 1950 Hassell Road Hoffman Estates, IL 60169-6308 Make sure the media label contains this number: NP-ASP-AE1.0 ADP Network Phone ASP Assistant Enterprise Loading
HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide
HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide Copyright and License 2008 Copyright Hewlett-Packard Development Company, L.P. Reproduction, adaptation, or translation without prior written
User Guide HD-WLU3R1 DriveStation Duo
User Guide HD-WLU3R1 DriveStation Duo EN 35011790 ver.01 Front Panel Layout Power LED Power On: blue RAID Maintenance: purple Power Off: off Access LEDs Access: blinking green Failure: red Rebuild: blinking
Seagate Manager. User Guide. For Use With Your FreeAgent TM Drive. Seagate Manager User Guide for Use With Your FreeAgent Drive 1
Seagate Manager User Guide For Use With Your FreeAgent TM Drive Seagate Manager User Guide for Use With Your FreeAgent Drive 1 Seagate Manager User Guide for Use With Your FreeAgent Drive Revision 1 2008
reflecta Super 8 Scanner
reflecta Super 8 Scanner User Manual 1 FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT This Equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part
Using Spectra on Mac
Using Spectra on Mac Last updated 03/22/2013 Please note: Instructions related to all third party software contained in this document are subject to change without notice. Please refer to the appropriate
User Guide HUAWEI UML397. Welcome to HUAWEI
User Guide HUAWEI UML397 Welcome to HUAWEI 1 Huawei UML397 4G LTE Wireless Modem User Manual CHAPTER 1 BEFORE USING YOUR UML397 WIRELESS MODEM ABOUT THIS USER MANUAL...4 WHAT S INSIDE THE PRODUCT PACKAGE...4
LinQ Mobile Software User s Guide
LinQ Mobile Software User s Guide Trademarks SMART Board, LinQ and the SMART logo are either registered trademarks or trademarks of SMART Technologies Inc. Windows is either a registered trademark or a
N600 WiFi USB Adapter
Model WNDA3100v3 User Manual December 2014 202-11470-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial
Checking the Package Contents. Installing the Printer Software. Connecting. Unpacking the. the Printer. Printer. Attaching
Installing the Printer Software Checking the Package Contents Connecting the Printer Unpacking the Printer Installing the Ink Cartridges Plugging in the Printer Attaching the Printer Parts 4032216-00 EUL
Legal Notes. Regarding Trademarks. 2012 KYOCERA Document Solutions Inc.
Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from
IDIS Solution Suite. Streaming Service. Software Manual. Powered by
Solution Suite Software Manual Streaming Service Powered by Before reading this manual This Operation Manual provides instructions for using Solution Suite, a network integration solution enabling remote
NETWORK PRINT MONITOR User Guide
NETWORK PRINT MONITOR User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable
Monitoring Network DMN
Monitoring Network DMN User Manual Table of contents Table of contents... 2 1. Product features and capabilities... 3 2. System requirements... 5 3. Getting started with the software... 5 3-1 Installation...
The following pages will help you to solve issues linked to the installation and first use of the Wintech Manager software and Wintech USB computer.
WINTECH MANAGER FAQ The purpose of this document is not to replace the complete user guide delivered on the Wintech Manager s CD. Most of the common question you may have about the use of the Wintech Manager
AT&T Unified Communications Voice. IP Communicator Installation Guide
AT&T Unified Communications Voice IP Communicator Installation Guide For Customer s System Administrator V1.1 July, 2015 Disclaimer The contents of the document may be revised by AT&T at any time without
3D MultiVision SOFTWARE OPERATING INSTRUCTIONS
MVL 3D MultiVision SOFTWARE OPERATING INSTRUCTIONS Changing the market from level to volume Accurate, reliable volume data from silos, open bins and warehouses where the diameters or areas are exceptionally
Quick Start Turning on the Tablet PC for the First Time
User s Manual DL46 Getting Started Congratulations on your purchase of a Tablet PC. The Tablet PC is a fully functional PC with built-in LAN, and wireless connectivity. With your Tablet PC you will be
How To Set Up Flir Cloud Client For Pc Or Mac Or Mac (For Pc Or Ipad) On A Pc Or Pc Or Mouse (For Mac) On An Iphone Or Ipa) On Pc Or Tv (For Ipa
Instruction Manual FLIR Cloud Services Client Instruction Manual FLIR Cloud Services Client #LX400018; r. 2.0/14567/14568; en-us iii Table of contents 1 Setting up FLIR Cloud Client for PC or Mac...1
Topaz Installation Sheet
Topaz Installation Sheet P/N 460924001E ISS 08FEB12 Content Introduction... 3 Recommended minimum requirements... 3 Setup for Internet Explorer:... 4 Topaz installation... 10 Technical support... 14 Copyright
ENLTV-FM3. PCI TV Tuner Adapter with FM Radio. User s Guide
ENLTV-FM3 PCI TV Tuner Adapter with FM Radio User s Guide User s Notice No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored
User Manual. Cone Beam 3D + 2D Panoramic Dental Imaging System
User Manual Cone Beam 3D + 2D Panoramic Dental Imaging System Copyright Dental Imaging Technologies Corporation 2013 This manual contains original instructions by Dental Imaging Technologies Corporation
HSP Update Tool V4.15.10
HSP Update Tool V4.15.10 Page 1 of 10 Copyright The data in this document may not be altered or amended without special notification from ETAS GmbH. ETAS GmbH undertakes no further obligation in relation
Getting Started. rp5800, rp5700 and rp3000 Models
Getting Started rp5800, rp5700 and rp3000 Models Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows
3M Stats and Status Software for 3M Detection System Model 8900/9900. Administrator s Guide
3M Stats and Status Software for 3M Detection System Model 8900/9900 Administrator s Guide Copyright 2009, 3M. All rights reserved. 3M Stats and Status Software for 3M Detection System Model 8900/9900
PU-USBX. USB over Ethernet Extender OPERATION MANUAL
PU-USBX USB over Ethernet Extender OPERATION MANUAL Safety Precautions Please read all instructions before attempting to unpack or install or operate this equipment, and before connecting the power supply.
VISION DX 600 Series
VISION DX 600 Series Digital Sensor System 0120 EU Representative: CE Partner 4U Esdoornlaah 13 3951DB Maarn The Netherlands Phone +31.434.442.524 Installation Instructions REF.KIT #30-A2160 PN 00-02-1610
Copyright Pro Softnet Corporation. All rights reserved. 2 of 24
Copyright Pro Softnet Corporation. All rights reserved. 2 of 24 Remote Access Helpdesk User Manual TABLE OF CONTENTS Introduction...4 Features...4 Administrator: Manage Technicians...5 Technician: Initiate
Network Administrator s Guide and Getting Started with Autodesk Ecotect Analysis
Autodesk Ecotect Analysis 2011 Network Administrator s Guide and Getting Started with Autodesk Ecotect Analysis This document describes how to install and activate Autodesk Ecotect Analysis 2011 software
Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting
Features Reference About Unified Communication System Before Using This Machine Starting a Meeting What You Can Do During the Meeting Leaving a Meeting Managing Address Book Changing Network Configuration
Manuals for This Product
Installation Guide Manuals for This Product Manuals for this product have the following structure. Read the manual according to your purpose for using this product. Disc Guides with this symbol are PDF
Diamond II v2.3 Service Pack 4 Installation Manual
Diamond II v2.3 Service Pack 4 Installation Manual P/N 460987001B ISS 26APR11 Copyright Disclaimer Trademarks and patents Intended use Software license agreement FCC compliance Certification and compliance
COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS
COMBOGARDPRO 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS IMPLEMENTATION PACKAGE The ComboGard Pro Software implementation package includes: 707012 ComboGard Pro Software Install
Polar Cardio GX: Help Topics
Polar Cardio GX: Help Topics Table of Contents The Polar Cardio GX system... 1 Quick steps... 2 PC requirements... 2 Training articles... 3 Bluetooth... 3 Introduction to hardware... 5 Base station...
KViewCenter Software User Manual 2012 / 04 / 20 Version 2.2.1.0
KViewCenter Software User Manual 2012 / 04 / 20 Version 2.2.1.0 Table of Contents Chapter 1. KViewCenter Interface... 5 1.1. Log in.... 5 1.2. Log out... 5 1.3. Control Panel... 6 1.4. Control Panel (Preview
WUA-0605 300Mbps Wireless USB Network Adapter
WUA-0605 300Mbps Wireless USB Network Adapter User Manual V1.0 Certification FCC CE FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
Web Designer for Modicon M340, Premium and Quantum
35016149 02/2010 Web Designer for Modicon M340, Premium and Quantum User Manual 02/2010 35016149.03 www.schneider-electric.com The information provided in this documentation contains general descriptions
IEEE 802.11b WLAN PC Card
IEEE 802.11b WLAN PC Card User s Guide Version: 1.3 August 2001 Please install the Utility/Driver first before inserting the PCMCIA Card. FCC Class B Radio Frequency Interference Statement The manufacturer
BlackHawk for MAC Software User Guide
BlackHawk for MAC Software User Guide Products: BLK-DH2 Series and BLK-HD Series DVRs Please read this manual before using your software, and always follow the instructions for safety and proper use. Save
Appointment Scheduler
EZClaim Appointment Scheduler User Guide Last Update: 11/19/2008 Copyright 2008 EZClaim This page intentionally left blank Contents Contents... iii Getting Started... 5 System Requirements... 5 Installing
Table of Contents. Chapter 5 Backed-up Video Playback & Exportation... 29 5.1 Playing back Backed-up Video... 29 5.2 Exporting Backed-up Video...
inex Backup Table of Contents Chapter 1 Introduction... 1 1.1 System Diagram... 2 Backup Service Registered on Administration Service... 2 Backup Service Registered on Federation Service... 3 Chapter 2
Network Installation Guide. Artisan 810 Series
Network Installation Guide Artisan 810 Series Before You Begin Make sure you installed ink cartridges and loaded paper as described on the Start Here sheet. Then follow the instructions in this guide to
Introduction Configuring Your HP Mouse Batteries Replacing the Batteries Mouse Sensor Technology Navigating the HP Mouse Control Center
Introduction Congratulations on your purchase of an HP mouse. This mouse is the latest in a wide range of computer peripherals manufactured by HP. It is designed to provide you with the highest level of
Magaya Software Installation Guide
Magaya Software Installation Guide MAGAYA SOFTWARE INSTALLATION GUIDE INTRODUCTION Introduction This installation guide explains the system requirements for installing any Magaya software, the steps to
MF652 USB Modem User Guide
MF652 USB Modem User Guide Connection Manager Software Guide... 2 Using your USB Modem... 4 Task bar information... 6 Using the SMS Interface... 7 Using the Phonebook... 9 Phonebook Notes:...10 Settings...11
How To Use A Brother Ql700
User's Guide QL-700 Be sure to read and understand this guide before using the machine. We recommend that you keep this guide nearby for future reference. www.brother.com US ENG ver.0 Thank you for purchasing
Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide
Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide Document Number: P0874391 Document Release: Standard 1.00 Date: November 1997 Year Publish FCC TM 1997 All rights reserved Printed in
EasyMP Multi PC Projection Operation Guide
EasyMP Multi PC Projection Operation Guide Contents Introduction to EasyMP Multi PC Projection... 7 EasyMP Multi PC Projection Features... 7 Connection to Various Devices... 7 Four-Panel Display... 8
Chapter 1 Downloading Images to Your Computer (Windows)
Software User Guide For the safe use of your camera, be sure to read the Safety Precautions thoroughly before use. Types of software installed on your computer varies depending on the method of installation
Net USER GUIDE MEDIA SHARING DEVICE
FCC DECLARATION OF CONFORMANCE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this
Chapter 4 Control Center
Chapter 4 Control Center Control Center is a central monitoring station solution (CMS) that provides the CMS operator with these major features: Access to client DVRs (See Remote DVR) Access to remote
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
Safety Precautions Read and understand this specifications, instruction manual, installation manual and catalog to make proper use of the product. WARNING If critical situations that could lead to user
Avigilon Control Center Server User Guide
Avigilon Control Center Server User Guide Version 4.10 PDF-SERVER-D-Rev1 Copyright 2011 Avigilon. All rights reserved. The information presented is subject to change without notice. No copying, distribution,
IDDERO HCx-KNX TOUCH PANELS. Quick start guide. www.iddero.com 130125-02
IDDERO HCx-KNX TOUCH PANELS Quick start guide www.iddero.com 130125-02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 IDDERO CONFIGURATION SOFTWARE... 3 2.1 Installation and First Steps...3 3 TOUCH PANEL CONFIGURATION...
MediaMed Software User Guide
MEDIAMED, INC MediaMed Software User Guide For MediaMed Version 2.0 Table of Contents Introducing MediaMed 2.0 Software...3 The Main Menu...3 Adding New Patients...4 Controls in this Screen... 4 Finding
IDIS Solution Suite. Backup Service. Software Manual. Powered by
Solution Suite Software Manual Backup Service Powered by Before reading this manual This Operation Manual provides instructions for using Solution Suite, a network integration solution enabling remote
idex Manual Contact details Producer: FOCI BV. The Netherlands www.foci.nl [email protected]
idex USB Manual Contact details Producer: FOCI BV. The Netherlands www.foci.nl [email protected] 2 Index Index... 3 1. General... 4 2. Get started!... 5 3. First use... 7 4. FOCI idex Software... 14 5. Operating
Personal Call Manager User Guide. BCM Business Communications Manager
Personal Call Manager User Guide BCM Business Communications Manager Document Status: Standard Document Version: 04.01 Document Number: NN40010-104 Date: August 2008 Copyright Nortel Networks 2005 2008
IDIS Solution Suite. Backup Service. Software Manual. Powered by
Solution Suite Software Manual Backup Service Powered by Before reading this manual This Operation Manual provides instructions for using Solution Suite, a network integration solution enabling remote
Call Center - Agent Application User Manual
Forum 700 Call Center Agent Application User Manual Legal notice: Belgacom and the Belgacom logo are trademarks of Belgacom. All other trademarks are the property of their respective owners. The information
FlashAir Configuration Software. User s Manual. (Windows) Revision 2
FlashAir Configuration Software User s Manual (Windows) Revision 2 1 FlashAir Configuration Software ( Software ) Support OS: Microsoft Windows XP SP3/ Windows Vista SP2 / Windows 7 (32bit/64bit) Software
Lifecycle Service Tool. Operator's manual
REF 542plus 1MRS756725 Issued: 23.12.2008 Version: A/23.12.2008 REF 542plus Contents Copyrights... 5 1. Introduction...7 1.1. This manual... 7 1.2. Use of symbols... 7 1.3. Intended audience... 7 1.4.
CONFIGURING MICROSOFT SQL SERVER REPORTING SERVICES
CONFIGURING MICROSOFT SQL SERVER REPORTING SERVICES TECHNICAL ARTICLE November/2011. Legal Notice The information in this publication is furnished for information use only, and does not constitute a commitment
Global VPN Client Getting Started Guide
Global VPN Client Getting Started Guide 1 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your system. CAUTION: A CAUTION indicates potential
SPEECHEXEC. www.philips.com/dictation. Version 1.0 for Mac. EN User manual 3. DE Benutzerhandbuch 13. FR Manuel de l utilisateur 23
For product information and support, visit www.philips.com/dictation SPEECHEXEC Version 1.0 for Mac EN User manual 3 DE Benutzerhandbuch 13 FR Manuel de l utilisateur 23 ES Manual del usuario 33 NL Gebruikershandleiding
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started Contents StrikeRisk v6.0 Introduction 1/1 1 Installing StrikeRisk System requirements Installing StrikeRisk Installation troubleshooting
Digital panoramic X-ray for practical diagnostics
ORTHOPHOS XG 3 instruments treatment centers Imaging systems cad/cam systems ORTHOPHOS XG 3 Digital panoramic X-ray for practical diagnostics System concept Standard panoramic X-ray with proven technology.
LBP-1210 Laser Printer
LBP-1210 Laser Printer Getting Started Guide IMPORTANT: Read this manual carefully before using your printer. Save this manual for future reference. Copyright Copyright 2002 Canon Inc. All information
A6210 WiFi USB Adapter 802.11ac USB 3.0 Dual Band User Manual
802.11ac USB 3.0 Dual Band User Manual August 2014 202-11373-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the
Installation & Licensing Guide. AquiferTest Pro. An Easy-to-Use Pumping Test and Slug Test Data Analysis Package
Installation & Licensing Guide AquiferTest Pro An Easy-to-Use Pumping Test and Slug Test Data Analysis Package Table of Contents Software Maintenance and Support... 3 How to Contact SWS... 3 System Requirements...
EPSON Scan Server & EPSON TWAIN Pro Network
EPSON Scan Server & EPSON TWAIN Pro Network EPSON Scan Server & EPSON TWAIN Pro Network SCANNER UTILITY PROGRAMS All rights reserved. No part of this publication may be reproduced, stored in a retrieval
This document describes the standard software installation process for Doors.NET software.
Doors.NET installation and controller configuration is a three step process. Each of these steps has its own document, with controller configuration broken into separate documents per hardware type. software
