VISION DX 600 Series
|
|
|
- Percival Carroll
- 10 years ago
- Views:
Transcription
1 VISION DX 600 Series Digital Sensor System 0120 EU Representative: CE Partner 4U Esdoornlaah DB Maarn The Netherlands Phone Installation Instructions REF.KIT #30-A2160 PN REV. G ECN P2335 REV. D
2 Vision DX 600 Series Digital Sensor System Installation Instructions Rev. D Midmark Corporation 675 Heathrow Drive Lincolnshire, IL 60008, U.S.A. Phone +1 (847) Toll Free +1 (888) Fax: +1 (847) Copyright 2009 Progeny. All rights reserved.
3 Scope This manual provides the technician with installing instructions for the following units and software: Standalone Version of Vision DX Factory-Integrated Version of Vision DX in Preva Plus, Preva Mobile Plus, VetVision Complete, and VetVision Complete Mobile Preva to Preva Plus, Preva Mobile to Preva Mobile Plus, VetVision DC to VetVision Complete, and VetVision Mobile to VetVision Complete Mobile Upgrade Kits Progeny Imaging Installing the Sensor calibration files NOTE: It is recommended that the installing technician review the instructions before attempting to install or upgrade any component. Getting Assistance Contact Progeny Technical Service at +1 (847) ext. 3 or Toll Free (U.S. and Canada) at +1 (888) ext. 2 for any questions, concerns or suggestions for improvement of this or any other guide. To facilitate your service call, the following information should be ready and available: Your computer operating system (Windows Vista, Windows XP, Mac OS) Version of Progeny Imaging software Serial number of your Vision DX system and sensor Type of Progeny Imaging installation (standalone, peer-to-peer network, client-server network) C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
4 Table of Contents Section 1: Introduction... 6 Overview... 6 Before You Begin... 6 PC and Software... 6 Check System Contents... 6 Tools Required... 8 Additional Documentation... 8 Section 2: Standalone Version of Vision DX... 9 Section 3: Factory-Integrated Vision DX into Preva Plus (or VetVision Complete) Section 4: Factory-Integrated Vision DX into Preva Mobile Plus (or VetVision Complete Mobile) Section 5: Preva to Preva Plus (or VetVision DC to VetVision Complete) Upgrade Kit Section 6: Preva Mobile to Preva Mobile Plus (or VetVision DC Mobile to VetVision Complete Mobile) Upgrade Kit Section 7: Hardware Options Option 1: Integrated USB-to-CAT5 Extender (part # ) Option 2: Standalone USB-to-CAT5 Extender (part # ) Option 3: A/B Switch (For pass through application) (part #30-A2153) Section 8: Progeny Imaging Overview Features and Functions Progeny Imaging Components Supported Image Acquisition Systems Bridge to Third-party Applications Recommended System Requirements Before You Begin Overview of the Installation Process About the Progeny Installation Disk Before Installing Progeny Imaging Installation Configurations Standalone Configuration Networked Configuration Mixed (Standalone and Networked) Configuration Uninstalling Progeny Imaging C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
5 Installing Progeny Imaging Uninstalling Progeny Device Service Logging in for the First Time Progeny Imaging Database in Networked Configuration Configure sharing for the Progeny Imaging directory in Windows Domain Network Configure sharing for the Progeny Imaging directory on a Workgroup Network Configure MS SQL Server for Network Access Configuring Progeny Imaging to Use a Networked Database Section 9: Sensor Calibration in Progeny Imaging Section 10: Configuring Progeny Imaging to Publish to a PACS Server C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
6 Section 1: Introduction Overview The Vision DX Sensor System is an intraoral digital sensor system used with an intraoral X-Ray to capture digital images of human dentition. The Progeny Vision DX Sensor System is available in two configurations: Standalone Interface Module and Sensor, connected directly to a PC Integrated Integrated into and part of the Preva Plus or VetVision Complete system In addition, the integrated version of Vision DX is available as upgrade kit to existing Preva Plus or VetVision Complete systems. This guide is intended to serve as an Installation Guide for both, the standalone and integrated configurations of the Progeny Vision DX Sensor System, using Progeny Imaging or other imaging software programs. Before You Begin PC and Software You must have a dedicated PC with a 32-bit or 64-bit operating system. The operating system may be Windows XP Professional or Windows Vista, and at least one USB port must be available. Image capture and management software must be installed on the computer(s) that will host the Vision DX Sensor System. If you are using Progeny Imaging Software, it must be installed on every PC that will interface with the Vision DX Sensor System. If you are not using Progeny Imaging, then compatible image capture and management software must be installed on all PC to be used. Contact your Dental Equipment Dealer or Progeny Technical Service for a list of compatible imaging software programs. For Progeny Imaging software installation and use, refer to the documentation shipped with the Progeny Imaging Installation Disk, or contact Progeny Technical Service. Check System Contents Verify that all items listed on the Packing List are contained in your system order. If any item appears to be missing, contact Progeny Technical Service immediately C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
7 Table 1: Contents of Vision DX Standalone System PART NUMBER DESCRIPTION Vision DX USB Module X-Ray Sensor size X-Ray Sensor size X-Ray Sensor size 1 and size Sensor Sheaths, for Sensor size Sensor Sheaths, for Sensor size 2 45-A2005 Sensor Holder Sensor Calibration Files CD-ROM E USB Cable Table 2: Contents of Vision DX Integrated System PART NUMBER DESCRIPTION Vision DX USB Module X-Ray Sensor size X-Ray Sensor size X-Ray Sensor size 1 and size Sensor Sheaths, for Sensor size Sensor Sheaths, for Sensor size 2 45-A2004 Sensor Holder Sensor Calibration Files CD-ROM E USB Cable USB Bus-powered Hub Table 3: Contents of Optional Dual Host Switch PART NUMBER DESCRIPTION USB Dual-Host Switch USB Cable Extension Kit (integrated) USB Cable Extension Kit (standalone) C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
8 Tools Required No tools are required to install the Standalone Vision DX version. To install the Integrated Vision DX version the following tools will be needed together with all other tools required to install the Preva (VetVision DC): Philips Screwdriver, #1 Philips Screwdriver, #2 3 mm Hex Wrench Diagonal Cutter Additional Documentation Complete, detailed instructions are found in Progeny s technical support documentation. The manuals are identified as. Table 4: List of the available literature PART NUMBER DESCRIPTION Vision DX 600 Series Installation Guide Vision DX 600 Series User Guide Progeny Imaging Installation Guide Progeny Imaging User Guide, Human Applications Progeny Imaging User Guide, Veterinary Applications These documents can be provided upon request in either printed or electronic forms. Feel welcome to contact the Progeny Technical Support Group with any question C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
9 Section 2: Standalone Version of Vision DX In the standalone configuration, Vision DX consists of an X-Ray Sensor, Interface Module, and USB cables as shown on Figure 1, page 9. Figure 1 The Interface Module connects directly to the computer selected to run both the software and the sensor system as shown on Figure 2, page 9. Figure 2 To install the Standalone Vision DX Sensor System execute the following steps: 1. Plug the square end (Type B) of the provided USB cable into the square end connector of the Interface Module as shown on Figure 3, page 9. Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
10 2. Plug the Sensor connector into the receptacle on the front of the Vision DX Interface Module as shown on Figure 4, page 10. Figure 4 3. Plug the flat end (Type A) of the USB cable from the Module into any USB port on the PC as shown on Figure 5, page 10. Figure 5 If you have your Imaging software installed already, finish the installation of the Standalone Vision DX system by calibrating the sensor as it is described in Section 9 Sensor Calibration in Progeny Imaging, page 52. However, if you do not have your Imaging software installed or you are not sure, install the desired Imaging software and then proceed to Section 9 Sensor Calibration in Progeny Imaging, page 52. To install Progeny Imaging as your Imaging software, continue with Section 8 Progeny Imaging, page C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
11 Section 3: Factory-Integrated Vision DX into Preva Plus (or VetVision Complete) In the factory-integrated configuration, Vision DX Interface Module is already integrated with the Preva Plus (or VetVision Complete) Articulated Arm and the Unpowered USB Hub is already installed into the Preva Plus (or VetVision Complete) control module. Figure 6 To install the factory-integrated Vision DX Sensor System execute the following steps: NOTE: Install the factory-integrated Vision DX system after the Preva Plus (or VetVision Complete) is installed. 1. Attach the sensor holder to the articulating arm by peeling off the tab and exposing the sticky tape (see Figure 7 on page 11). Sensor holder Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
12 2. Plug the sensor connector into the Sensor Interface at the bottom of the Arm mount as shown on Figure 8, page 12. Figure 8 3. Place the sensor into the sensor holder as shown on Figure 9, page 12. Figure 9 4. Remove the access plate from the underside of the horizontal arm by removing the two Phillips head screws (see Figure 10 on page 12). Figure Locate the USB cable originating from the articulating arm and connect it to the USB cable located in the horizontal (see Figure 11 on page 13). NOTE: Feed the excess USB cable into to the horizontal arm taking care not to damage or pinch the USB cable C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
13 Figure Re-install the access plate that was removed in step 4 on page Remove the cover from the Preva Plus (VetVision Complete) control unit. 8. Locate the free end of the USB cable originating from the horizontal arm. If it is secured with a cable tie, carefully cut the cable tie. 9. Plug the USB cable from the horizontal arm into J1 of the unpowered USB Hub (see Figure 12 on page 13). Figure 12 J1 (Plug USB cable from horizontal arm here) Unpowered USB HUB J2 (Plug the 5 m USB cable here) Bracket 10. Connect the 5 m USB extender cable (part #E ) to J2 of the unpowered USB Hub (see Figure 12 on page 13). 11. Cut and clear a notch in the control cover using a set of diagonal cutters as shown on Figure 13, page 13. Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
14 12. Feed the 5 m USB extender cable through the notch in the bottom of the control unit cover and replace the cover. 13. Plug the 5 m USB cable from step 12 (page 14) into any port on the 4-port Hub. Make certain to energize the 4-port Hub with AC power adapter (see Figure 14 on page 14). Figure Plug the 4-port hub to an available USB port on the PC using the hub cable provided in the hub packaging (See Figure 15 on page 14). Figure 15 If any of the additional hardware options were purchased, continue with Section 7 Hardware Options, page 30. If no additional hardware options were purchased and if you have your Imaging software installed already, finish the installation of the Integrated Vision DX system by calibrating the sensor as it is described in Section 9 Sensor Calibration in Progeny Imaging, page 52. However, if you do not have your Imaging software installed or you are not sure, install the desired Imaging software and then proceed to Section 9 Sensor Calibration in Progeny Imaging, page 52. To install Progeny Imaging as your Imaging software, continue with Section 8 Progeny Imaging, page C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
15 Section 4: Factory-Integrated Vision DX into Preva Mobile Plus (or VetVision Complete Mobile) In the factory-integrated configuration, Vision DX Interface Module is already integrated with the Preva Mobile Plus (or VetVision Complete Mobile) Articulated Arm and the Unpowered USB Hub is already installed into the Preva Mobile Plus (or VetVision Complete Mobile) control module. To install the factory-integrated Vision DX Sensor System execute the following steps: NOTE: Install the factory-integrated Vision DX system after the Preva Mobile Plus (or VetVision Complete Mobile) is assembled. 1. Attach the sensor holder to the articulating arm by peeling off the tab and exposing the sticky tape (see Figure 16 on page 15). Sensor holder Figure Plug the sensor connector into the Sensor Interface at the bottom of the Arm mount as shown on Figure 17, page 15. Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
16 3. Place the sensor into the sensor holder as shown on Figure 18, page 16. Figure Connect the extender USB cable (part #E ) to the USB cable originating from the articulating arm (see Figure 19 on page 16). Extender cable (E ) Figure The other end of the extender USB cable (part #E ) will be located in the front of the operator panel mounting plate (see Figure 20 on page 16). Extender cable (E ) Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
17 6. With the cradle removed, route the extender USB cable through the hole located on the bottom of the cradle. Then route the CAT5 cable through the opening in the cradle (see Figure 21 on page 17). 7. Re-attach the cradle Figure Attach the CAT5 cable to the control panel as shown on Figure 22, page 17. Figure Attach the control panel on to the cradle (see Figure 23 on page 17). Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
18 10. Attach the extender cable that was routed in step 6 (page 17) to any available USB port on the 4-port hub mounted to the back of the cradle as shown on Figure 24, page 18. NOTE: Brand of 4-port hub may vary but installation procedure and mounting location does not change Figure Attach the 5 m USB extender cable (part #E ) to the 4-port hub as shown on Figure 25, page 18. Figure Attach the other end of the 5 m extender cable (part #E ) to any open USB port on the PC. If any of the additional hardware options were purchased, continue with Section 7 Hardware Options, page 30. If no additional hardware options were purchased and if you have your Imaging software installed already, finish the installation of the Integrated Vision DX system by calibrating the sensor as it is described in Section 9 Sensor Calibration in Progeny Imaging, page 52. However, if you do not have your Imaging software installed or you are not sure, install the desired Imaging software and then proceed to Section 9 Sensor Calibration in Progeny Imaging, page 52. To install Progeny Imaging as your Imaging software, continue with Section 8 Progeny Imaging, page C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
19 Section 5: Preva to Preva Plus (or VetVision DC to VetVision Complete) Upgrade Kit To upgrade an existing Preva (or VetVision DC) intraoral X-Ray system to Preva Plus (or VetVision Complete) a Vision DX upgrade kit must be use. The following upgrade kits are available: Upgrade Kit with Sensor size Upgrade Kit with Sensor size Upgrade Kit with Sensors size 1 and size Upgrade Kit without Sensor NOTE: Upgrading from Preva to Preva Plus (or VetVision DC to VetVision Complete) can be accomplished only on X-Ray systems manufactured after July 1, These X-Ray units have been adapted to accept the integration of the Progeny Vision DX sensor system. NOTE: The upgrade has to be accomplished after the Preva (or VetVision DC) is installed. 1. Remove the end caps (closest to the tube head) from the articulating arm by pulling them apart as shown on Figure 26, page 19. Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
20 2. Locate the cable tie that holds the end of the USB cable to the articulating arm see Figure 27 on page 20. Cable tie Figure Carefully cut the cable tie with a diagonal cutter. NOTE: Do not to cut the USB cable jacket. 4. Plug the USB cable into J1 of the Sensor Interface PCB arm mount as shown on Figure 28, page 20. J1 Sensor Interface PCB Figure Press the two matching covers together and secure with the 3 mm x 16 mm screw provided in the package. Use a 3 mm hex wrench to tighten (see Figure 29 on page 20). Figure 29 3mm x 16mm screw C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
21 6. Attach the sensor holder to the articulating arm by peeling off the tab and exposing the sticky tape (see Figure 30 on page 21). Figure 30 Sensor holder 7. Plug the sensor connector into the Sensor Interface at the bottom of the Arm mount as shown on Figure 31, page 21. Figure Place the sensor into the sensor holder as shown on Figure 32, page 21. Figure Remove the access plate from the underside of the horizontal arm by removing the two Phillips head screws (see Figure 33 on page 21). Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
22 10. Locate the USB cable originating from the articulating arm and connect it to the USB cable located in the horizontal (see Figure 34 on page 22). NOTE: Feed the excess USB cable into to the horizontal arm taking care not to damage or pinch the USB cable. Figure Re-install the access plate that was removed in step 9 on page Remove the cover from the Preva (VetVision DC) control unit. 13. Attach the unpowered USB Hub (part # ) to the bracket adjacent to the Logic PCB. Use the two 3 mm x 5 mm screws provided (see Figure 35 on page 22). Figure 35 J1 (Plug USB cable from horizontal arm here) Unpowered USB HUB J2 (Plug 5M USB cable here) Bracket 14. Locate the free end of the USB cable originating from the horizontal arm. If it s secured with a cable tie, carefully cut the cable tie. 15. Plug the USB cable from the horizontal arm into J1 of the unpowered USB Hub (see Figure 35 on page 22). 16. Connect the 5 m USB extender cable (part #E ) to J2 of the unpowered USB Hub (see Figure 35 on page 22) C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
23 17. Cut and clear a notch in the control cover using a set of diagonal cutters as shown on Figure 36, page 23. Figure Feed the 5 m USB extender cable through the notch in the bottom of the control unit cover and replace the cover. 19. Plug the 5 m USB cable from step 18 (page 23) into any port on the 4-port Hub. Make certain to energize the 4-port Hub with AC power adapter (see Figure 37 on page 23). Figure Plug the 4-port hub to an available USB port on the PC using the hub cable provided in the hub packaging (See Figure 38 on page 23). Figure 38 If any of the additional hardware options were purchased, continue with Section 7 Hardware Options, page 30. If no additional hardware options were purchased and if you have your Imaging software installed already, finish the installation of the Integrated Vision DX system by calibrating the sensor as it is described in Section 9 Sensor Calibration in Progeny Imaging, page 52. However, if you do not have your Imaging software installed or you are not sure, install the desired Imaging software and then proceed to Section 9 Sensor Calibration in Progeny Imaging, page 52. To install Progeny Imaging as your Imaging software, continue with Section 8 Progeny Imaging, page C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
24 Section 6: Preva Mobile to Preva Mobile Plus (or VetVision DC Mobile to VetVision Complete Mobile) Upgrade Kit To upgrade an existing Preva Mobile (or VetVision DC Mobile) intraoral X-Ray system to Preva Mobile Plus (or VetVision Complete Mobile) a Vision DX upgrade kit must be use. The following upgrade kits are available: Upgrade Kit with Sensor size Upgrade Kit with Sensor size Upgrade Kit with Sensors size 1 and size Upgrade Kit without Sensor NOTE: Upgrading from Preva Mobile to Preva Mobile Plus (or VetVision DC Mobile to VetVision Complete Mobile) can be accomplished only on X-Ray systems manufactured after July 1, These X-Ray units have been adapted to accept the integration of the Progeny Vision DX sensor system. NOTE: The upgrade has to be accomplished after the Preva Mobile (or VetVision DC Mobile) is assembled. 1. Remove the end caps (closest to the tube head) from the articulating arm by pulling them apart as shown on Figure 39, page 24. Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
25 2. Locate the cable tie that holds the end of the USB cable to the articulating arm see Figure 40 on page 25. Cable tie Figure Carefully cut the cable tie with a diagonal cutter. NOTE: Do not to cut the USB cable jacket. 4. Plug the USB cable into J1 of the Sensor Interface PCB arm mount as shown on Figure 41, page 25. J1 Sensor Interface PCB Figure Press the two matching covers together and secure with the 3 mm x 16 mm screw provided in the package. Use a 3 mm hex wrench to tighten (see Figure 42 on page 25). Figure 42 3mm x 16mm screw C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
26 6. Attach the sensor holder to the articulating arm by peeling off the tab and exposing the sticky tape (see Figure 43 on page 26). Figure 43 Sensor holder 7. Plug the sensor connector into the Sensor Interface at the bottom of the Arm mount as shown on Figure 44, page 26. Figure Place the sensor into the sensor holder as shown on Figure 45, page 26. Figure Connect the extender USB cable (part #E ) to the USB cable originating from the articulating arm (see Figure 46 on page 26). Extender cable (E ) Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
27 10. The other end of the extender USB cable (part #E ) will be located in the front of the operator panel mounting plate (see Figure 47 on page 27). Extender cable (E ) Figure With the cradle removed, route the extender USB cable through the hole located on the bottom of the cradle. Then route the CAT5 cable through the opening in the cradle (see Figure 48 on page 27). 12. Re-attach the cradle Figure Attach the CAT5 cable to the control panel as shown on Figure 49, page 27. Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
28 14. Attach the control panel on to the cradle (see Figure 50 on page 28). Figure Attach the 4-port USB hub to the back of the cradle mount with the supplied Velcro (see Figure 51 on page 28). Make certain to energize the 4-port hub with AC power. NOTE: Brand of 4-port hub may vary but installation procedure and mounting location does not change Figure Attach the extender cable that was routed in step 11 (page 27) to any available USB port on the 4-port hub as shown on Figure 51, page Attach the 5 m USB extender cable (part #E ) to the 4-port hub as shown on Figure 52, page 28. Figure Attach the other end of the 5 m extender cable (part #E ) to any open USB port on the PC C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
29 If any of the additional hardware options were purchased, continue with Section 7 Hardware Options, page 30. If no additional hardware options were purchased and if you have your Imaging software installed already, finish the installation of the Integrated Vision DX system by calibrating the sensor as it is described in Section 9 Sensor Calibration in Progeny Imaging, page 52. However, if you do not have your Imaging software installed or you are not sure, install the desired Imaging software and then proceed to Section 9 Sensor Calibration in Progeny Imaging, page 52. To install Progeny Imaging as your Imaging software, continue with Section 8 Progeny Imaging, page C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
30 Section 7: Hardware Options Option 1: Integrated USB-to-CAT5 Extender (part # ) This extender provides for a longer cable run than permitted by USB cables. A USB to/from CAT5 Converter is used on both the computer end and the sensor end with a Category 5 Shielded Twisted Pair (STP) cable in between that can run up to 15 m (50 ft) in length. In the cases where the PC cannot reach the Preva Plus control unit with the 5 m USB cable, an USB-to-CAT5 Extender may be used. 1. Attach the Integrated USB-to-CAT5 Converter (part # ) to the bracket adjacent to the Logic PCB. Use the two 3 mm x 5 mm screws provided as shown on Figure 53, page 30. NOTE: If an unpowered USB hub (part # ) is already installed you will have to remove it first and replace it with the Integrated USB-to-CAT5 Converter as described in the step above. Figure 53 J1 Plug in the Horizontal arm USB cable here Integrated USB-to-CAT5 Converter 8P8C modular connector Plug the 15 m (50 ft) Category 5 STP cable here 2. Plug the USB cable from the horizontal arm into the Integrated USB-to-CAT5 Converter at J1 (see Figure 53 on page 30). 3. Plug one end of the 15 m (50 ft) Category 5 STP cable into the 8P8C modular connector on the Integrated USB-to-CAT5 Converter (see Figure 53 on page 30) C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
31 4. Plug the other end of the Category 5 STP cable to the CAT5-to-USB Converter (part #30-A2154) as shown on Figure 54, page 31. CAT5 to USB convertor Figure 54 When all additional hardware options are installed and if you have your Imaging software installed already, finish the installation of the Integrated Vision DX system by calibrating the sensor as it is described in Section 9 Sensor Calibration in Progeny Imaging, page 52. However, if you do not have your Imaging software installed or you are not sure, install the desired Imaging software and then proceed to Section 9 Sensor Calibration in Progeny Imaging, page 52. To install Progeny Imaging as your Imaging software, continue with Section 8 Progeny Imaging, page 35. Option 2: Standalone USB-to-CAT5 Extender (part # ) This extender provides for a longer cable run than permitted by USB cables. A USB to/from CAT5 Converter is used on both the computer end and the sensor end with a Category 5 Shielded Twisted Pair (STP) cable in between that can run up to 15 m (50 ft) in length. To install, plug the USB cable from the Vision DX control unit to the corresponding half of the Standalone USB-to-CAT5 Converter (see Figure 55 on page 31). Than, plug the 15 m (50 ft) Category 5 STP cable into the 8P8C modular connectors on both Standalone USB-to-CAT5 Converters, and than plug the second half of the Standalone USB-to-CAT5 Converter to the PC to as shown on Figure 55, page 31. PC connection USB-to-CAT5 Extender USB cable to Vision DX Figure 55 CAT5 Cable C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
32 When all additional hardware options are installed and if you have your Imaging software installed already, finish the installation of the Integrated Vision DX system by calibrating the sensor as it is described in Section 9 Sensor Calibration in Progeny Imaging, page 52. However, if you do not have your Imaging software installed or you are not sure, install the desired Imaging software and then proceed to Section 9 Sensor Calibration in Progeny Imaging, page 52. To install Progeny Imaging as your Imaging software, continue with Section 8 Progeny Imaging, page 35. Option 3: A/B Switch (For pass through application) (part #30-A2153) It may be necessary to use a dual host switch in the case that a Vision DX Integrated (Preva Plus) is installed in a pass through cabinet. The dual host switch allows for two computers in separate operatories to utilize the same integrated USB sensor. 1. Remove the unpowered USB Hub from the bracket inside the control unit if it is installed (see Figure 56 on page 32). Unpowered USB hub. Figure Remove the control cover insert (see Figure 57 on page 32). NOTE: Push from the inside of the cover to remove the insert. Control cover insert Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
33 3. Install the Dual-Host Switch Assembly (see Figure 58 and Figure 59 on page 33). NOTE: Install from the inside of the control cover. Dual Host Switch (part # ) Figure 58 Dual host Switch Figure Plug the USB cable from the Preva Plus Horizontal Arm into J2 on the Dual-Host Switch Assembly as shown on Figure 60, page Plug the two USB cables for each of the two PCs into J1 and J3 on the Dual-Host Switch Assembly (see Figure 60 on page 33). Vision DX Integrated USB cable from the Preva Plus Horizontal Arm USB cables that connect to each PC Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
34 6. Route the two USB cables through the notch in the bottom of the Control Unit cover and replace the cover (see Figure 60 on page 33). Figure 61 USB cables that connect to each PC 7. Plug one USB cable into a USB Port on each of the PCs. If the distance to any of the PCs is longer than 5 m, install the optional Standalone USB-to-CAT5 Extender as it is described in Option 2: Standalone USB-to-CAT5 Extender (part # ) on page 31. When all additional hardware options are installed and if you have your Imaging software installed already, finish the installation of the Integrated Vision DX system by calibrating the sensor as it is described in Section 9 Sensor Calibration in Progeny Imaging, page 52. However, if you do not have your Imaging software installed or you are not sure, install the desired Imaging software and then proceed to Section 9 Sensor Calibration in Progeny Imaging, page 52. To install Progeny Imaging as your Imaging software, continue with Section 8 Progeny Imaging, page C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
35 Section 8: Progeny Imaging Overview Features and Functions Progeny Imaging acquires, displays, and stores digital dental X-Rays and intraoral video images. Progeny Imaging stores digital sensor images in DICOM format (Digital Imaging and Communications in Medicine). The DICOM format assures that each image contains patient identification and acquisition information. You can use Progeny Imaging to: Create login IDs for users of Progeny Imaging Manage patient records Acquire, manipulate, and communicate images Configure devices to work with Progeny Imaging NOTE: For information on using Progeny Imaging, refer to the Progeny Imaging User's Manual. Progeny Imaging Components Progeny Imaging consists of three main components: a graphical user interface, a database, and application folders. The graphical user interface is used to view and manipulate images. The database, which runs on MS SQL Server 2005 Express, stores user and patient information. The application folders store system settings, device configurations, and patient images. Progeny Imaging needs to be installed on every computer where you want to view or acquire and store images. By default, the Progeny Imaging database is installed on the same computer where the graphical user interface is installed. This is the standalone (application) configuration. You can also have the graphical user interface point to a central database on another computer within the office network. This is the networked (application) configuration. Supported Image Acquisition Systems Progeny Imaging works with Progeny Vision DX 600 Series, Vision DX 500 Series, and MPSe Digital Intraoral X-Ray image acquisition modules and sensors as well as with the Progeny Vivid Intraoral Video Camera. The Progeny Vision DX 600 Series Digital Intraoral X-Ray Sensor System and the Progeny Vivid Video Camera are USB-based devices. These devices can only be installed directly to a C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
36 computer's USB 2.0 port (standalone device configuration) and cannot be shared across a network. The Progeny Vision DX 500 Series and Progeny MPSe Intraoral X-Ray Sensor Systems are network-based devices. Two options exist for installing these devices: Standalone configuration (default) the sensor system is installed (in Standalone mode) directly to the computer's network port. In this configuration, the sensor system can only be used from the computer where it is connected. The computer in a Standalone configuration can access an office network or the Internet only if it has a second network port. Networked configuration the sensor system is installed using the default Standalone configuration and then reconfigured to be in Static IP mode. It can then be attached directly to a port of the same network (thru a hub or switch) where the client computer is. In this configuration, all computers and sensor system(s) are on the same network, and the sensor system can be accessed from computers in different rooms or the sensor system could be moved between different network ports. The network could be also attached to Internet and the computers may access the network and/or Internet without additional network port. Bridge to Third-party Applications PIBridge is an additional software application from Progeny Dental that enables you to use Progeny Imaging with 3 rd -party applications, such as practice management software (PMS). With PIBridge, you can add Progeny Imaging's image acquisition and analysis capability seamlessly to your practice management software. After accessing a patient's records in your practice management application, you use PIBridge commands to "call" Progeny Imaging. At your command, Progeny Imaging opens for you to acquire images and create studies. For information on PIBridge and using a 3rd party application with Progeny Imaging, contact Progeny Technical Support. Recommended System Requirements The performance of Progeny Imaging software is affected by the amount of RAM and storage memory available to the system for acquisition, displaying, storing, and printing digital X-Ray images. The recommended requirements are listed below as a guideline only. As you review these guidelines, be aware that your patient volume, and the specific demands of your practice, may require you to adjust these guidelines accordingly. The system requirements of other programs operating on the same computer or network may affect these guidelines as well C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
37 Table 5: Recommended System Requirements Component Computer Hardware Memory System Operating System Disk Space Display Settings Requirement PC-compatible Pentium 4 / 1.4 GHz or greater computer Mac Powerbook Pro (with required Operating System see below) 2 GB RAM or higher recommended (minimum 1 GB) Microsoft Windows XP with Service Pack 2 Microsoft Vista (all editions) Mac OS X Leopard with Boot Camp running Windows (Progeny Imaging does not support Windows running as a virtual machine.) 450 MB minimum NOTE: You will need additional disk space depending on the size of your practice, and the number of images and other information you plan to store. Each image is approximately 4 MB. For example, if you plan to store 75,000 images, you will need approximately 300 GB x 768 (16-bit or higher) with 32 MB (or higher) of Video RAM NOTE: It is possible for you to increase these settings based on the actual settings defined by the video adapter and/or capture card installed in the system. As a rule, the better your video adapter or capture card the better your images. Before You Begin Overview of the Installation Process You must install Progeny Imaging on every computer where you want to view, acquire and store images. To install Progeny Imaging you do the following: 1. Remove any previous version of Progeny Imaging 2. Install the current version of Progeny Imaging 3. Open the software and login as the Administrator 4. (Additional step only If you are upgrading from Progeny Imaging 1.1.x.x): Remove Progeny Device Service About the Progeny Installation Disk Progeny Imaging is installed from the Progeny Installation disk. The disk also contains the help file and the database software MS SQL Server 2005 Express Edition. If MS SQL Server is not already installed on your computer, the Progeny Software Installer will install it C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
38 Before Installing Progeny Imaging Ensure that you are logged into your computer using an account that has Windows computer administrator privileges. NOTE: Progeny Imaging requires that all users be logged into Windows as a computer administrator. Installation Configurations Progeny Imaging supports two different configurations of installing Standalone and Networked. The Image Database and the Network-based image acquisition systems (such as Vision DX 500 Series and MPSe) could be installed in either mode. The Progeny Imaging graphical user interface and the USB-based image acquisition systems (such as Vision DX 600 Series and Vivid) can be installed only in standalone mode. Selecting an installation mode for one component does not limit the installation mode of any other component. Standalone Configuration Progeny Imaging component is installed in Standalone configuration if the component is accessible only from the computer where it is installed. Standalone also refers to the configuration in which a Network-based device (such as Vision DX 500 Series and MPSe) is connected to a dedicated network port on that computer. In the standalone configuration shown on Figure 62 (page 38), the computer uses the Progeny Imaging database and application folders located on the computer. The computer has both Vision DX 600 Series and Vision DX 500 Series image acquisition systems connected to it. The Vision DX 600 Series is connected to a USB 2.0 port on the computer. The Vision DX 500 Series is connected to an available network port dedicated for that sensor system. Networked Configuration Figure 62 Progeny Imaging component is installed in Networked configuration if the component is accessible and shared between the computer where it is installed and the other computers connected thru network to that computer. In this case, the computer where the component is installed acts as Server, and all computers act as Clients for the functionality provided by the component. Networked also refers to the configuration in which a Network-based device (such as Vision DX 500 Series and MPSe) is connected directly to the network and is shared between multiple computers C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
39 If the Progeny Imaging Database is installed in Networked configuration on a computer designated to act as a server, all computers that have Progeny Imaging graphical user interface can access the image database and can view centrally located patient images. In the networked configuration shown on Figure 63 (page 39), Progeny Imaging is installed on each computer and on the office server. All computers use the Progeny Imaging database on the office server and the image acquisition module connected to the network hub. Figure 63 Mixed (Standalone and Networked) Configuration Many offices use a combination of standalone and networked configurations, similar to the example shown on Figure 64 (page 39). Figure 64 In this example, Computer A has a Vision DX 600 Series image acquisition system (always standalone because it is USB-based). In addition, Computer A has two network ports, one of which is used for the Vision DX 500 Series sensor system that is installed in standalone configuration. The other network port on computer A is used to connect the computer to the office network, where it accesses the Progeny Imaging database, a second Vision DX 500 Series module set in networked configuration, and Internet, if the server provides Internet access. Computers B and C have one network port which they use to access the Progeny Imaging database and patient images on the office server, the Vision DX 500 Series on the office network hub and Internet, if the network provides access. All computers in this configuration can access the Vision DX 500 Series connected to the network, but only C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
40 Computer A can use the Vision DX 600 Series and Vision DX 500 Series modules connected directly to it. Uninstalling Progeny Imaging Always uninstall the earlier version of Progeny Imaging before installing the latest one when upgrading from a previous version of Progeny Imaging. NOTE: Uninstalling Progeny Imaging or Progeny Device Service does not remove the Imaging database or MS SQL Server 2005 Enterprise Edition. These components will be used if you re-install Progeny Imaging. To uninstall Progeny Imaging from a computer that has Windows XP operating system, follow the steps bellow: 1. From the Windows Start menu, select Control Panel. Then click on Add or Remove Programs icon. 2. In the Add or Remove Programs screen, select Progeny Imaging. 3. Click Remove. If the computer has Windows Vista operating system, follow the steps bellow: 1. From the Windows Start menu, select Control Panel. Then click on Programs and Features icon. 2. In the Programs and Features screen, select Progeny Imaging. 3. Click Remove. Installing Progeny Imaging To install Progeny Imaging follow the steps bellow: 1. Insert the Progeny Imaging Installation disk into the computer s optical (CD-ROM or DVD) drive. The Progeny Software Installer starts automatically (see Figure 65 on page 41). NOTE: If the Progeny Software Installer does not start automatically, use the Windows Start menu and select Run. Then type the path to the program on the Progeny Imaging Installation disk C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
41 Figure In the Progeny Imaging Software Installer, click Install Progeny Imaging. 3. In the pop-up message, click "Yes" to confirm that you want to start the installation. 4. If your computer does not have the Visual C++ Runtime Libraries, you will be asked to install them. When asked, click Install. 5. If your computer does not have MS SQL Server 2005 Express Edition installed, you will see a license agreement. Read it and click Accept. You will see the Progeny Imaging screen. 6. In the Progeny Imaging screen, click "Next" (see Figure 66 on page 41). Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
42 7. In the Welcome screen, click "Next" (see Figure 67 on page 42). Figure In the Select Patient Target screen, select the appropriate type of practice based on your patient type. Then click "Next". 9. In the Confirm Installation screen, click Next to launch the installation. When the installation is complete, you will see the Installation Complete screen. 10. Click Close (see Figure 68 on page 42). Figure In the Progeny Software Installer, click Exit. 12. In the pop-up message, click "Yes" to confirm that you want to exit. 13. Installation is complete C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
43 Uninstalling Progeny Device Service Uninstall Progeny Device Service if you are upgrading from Progeny Imaging 1.1.x.x. NOTE: Uninstalling Progeny Imaging and the Progeny Device Service does not remove the Progeny Imaging database or MS SQL Server 2005 Enterprise Edition. These components will be used if you re-install Progeny Imaging. To uninstall Progeny Device Service from a computer that has Windows XP operating system, follow the steps bellow: 1. From the Windows Start menu, select Control Panel. Then click on Add or Remove Programs icon. 2. In the Add or Remove Programs screen, select Progeny Device Service. 3. Click Remove. 4. Delete the shortcut to Progeny Device Service from the Windows Programs menu. To delete the shortcut, display the Programs menu and right-click on Progeny Device Service. When the options menu appears, select "Delete". If the computer has Windows Vista operating system, follow the steps bellow: 1. From the Windows Start menu, select Control Panel. Then click on Programs and Features icon. 2. In the Programs and Features screen, select Progeny Device Service. 3. Click Remove. 4. Delete the shortcut to Progeny Device Service from the Windows Programs menu. To delete the shortcut, display the Programs menu and right-click on Progeny Device Service. When the options menu appears, select "Delete". Logging in for the First Time Every time Progeny Imaging is launched, the Login window appears. You must log in to use Progeny Imaging. Progeny Imaging supports administrator and ordinary users. Immediately after installing Progeny Imaging, you will log in as Administrator. Later, the Administrator can use the User Manager window to set up user IDs and passwords for other administrators and/or ordinary users. Before Logging In ensure that you are logged into an account that has Windows computer administrator privileges. NOTE: Progeny Imaging requires that all users to be logged into Windows as a computer administrator C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
44 To Log in for the First Time 1. On your computer's desktop, double-click the Progeny Imaging icon, or select Progeny Imaging from your Windows Start menu. 2. In the Login screen User ID field, type Administrator (see Figure 69 on page 44). NOTE: If you are logging into the application in another language, you must use the localized operating system's version of the "Administrator" login. Figure Leave the Password field blank.(no Password required) 4. Click Login. Progeny Imaging Database in Networked Configuration By default, Progeny Imaging uses the database that is installed on the same computer that runs the Progeny Imaging graphical user interface (GUI). However, you can choose to have Progeny Imaging use a database on one a server (or a computer designated to be the server) on the office network. This involves configuring sharing and remote access for the database and configuring of all Progeny Imaging GUIs to use the database on the server. By default Progeny Imaging stores patient images on the same computer where the Progeny Imaging GUI is installed. You cannot change or relocate the image storage location. However, if you choose to have the Progeny Imaging database on a server (or a computer designated to be the server), you have to configure the images folder on the server to be shared. Configuring the database for use on a network requires the following tasks to be executed on the server computer (or the computer designated to be the server): Configure sharing for the Progeny Imaging directory Configure MS SQL Server to allow remote access NOTE: Progeny Imaging requires that your office network to be set as a workgroup (Peer-to-Peer, P2P) or as a Windows domain (client-server). In all cases, all users must have local administrator privileges on all client computers. On a domain network, a domain server is required for authentication C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
45 NOTE: Progeny Imaging has to be installed and configured on the server (or the computer designated to be the server) and on all client computers. Take note of the server computer (machine) name as it will be used during the configuration of all client computers. If the Progeny Image Database is intended to be used in Standalone configuration, continue with Section 9 Sensor Calibration in Progeny Imaging on page 52. Configure sharing for the Progeny Imaging directory in Windows Domain Network To Configure Sharing for the Progeny Imaging Directory on a Windows Domain Network follow the steps below: 1. In Windows Explorer navigate to the folder at C:\Program Files\Progeny. 2. In the Progeny folder, highlight the Progeny Imaging folder. 3. Right click and select Sharing and Security (see Figure 70 on page 45). Figure In the Progeny Imaging Properties box, select the Sharing tab. 5. Click Share this folder. 6. Click Permissions. 7. Click Add. 8. Click Advanced C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
46 9. In the Select Users, Computers, or Groups box, click Find Now (see Figure 71 on page 46). 10. Select Network Service. 11. Click OK (see Figure 72 on page 46). Figure Click OK. Figure In the Permissions for Progeny Imaging box, select Allow for Full Control (see Figure 73 on page 46). Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
47 14. Click OK. 15. Click OK. The Progeny Imaging folder icon should indicate that the folder is now shared. Configure sharing for the Progeny Imaging directory on a Workgroup Network To Configure Sharing for the Progeny Imaging Directory on a Workgroup (Peer-to-Peer, or P2P) Network follow the steps below: 1. Navigate to the folder at C:\Program Files\Progeny. 2. In the Progeny folder, highlight the Progeny Imaging folder. 3. Right click and select Sharing and Security. 4. In the Progeny Imaging Properties box, select the Sharing tab (see Figure 74 on page 47). Figure Click to select the sentence link: If you understand the security risks but want to share files without running the wizard, click here. 6. Select Just enable file sharing and click OK (see Figure 75 on page 47). Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
48 7. The Sharing tab now shows that Progeny Imaging is shared. Select Allow network users to change my files and click OK (see Figure 76 on page 48). Figure In the warning about share name length, click OK. Configure MS SQL Server for Network Access To Configure MS SQL Server for Network Access follow the steps below: 1. From the Windows Start menu, select Programs > Microsoft SQL Server 2005 > Configuration Tools > SQL Server Configuration Manager. 2. In the SQL Server Configuration Manager, expand SQL Server 2005 Network Configuration. 3. Click Protocols for SQLEXPRESS (see Figure 77 on page 48). Figure Verify that Shared Memory, Named Pipes, and TCP/IP are Enabled. If any of these items are not enabled, select, right-click, and enable them. Ignore any warnings that are displayed. 5. Expand SQL Native Client Configuration C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
49 6. Click Client Protocols. 7. Verify that Shared Memory, Named Pipes, and TCP/IP are Enabled. If any of these items are not enabled, select, right-click, and enable them. Ignore any warnings that are displayed. 8. Close the SQL Server Configuration Manager. 9. From the Windows Start menu, select Programs > Microsoft SQL Server 2005 > Configuration Tools > SQL Server Surface Area Configuration. 10. Near the bottom of the screen, click Surface Area Configuration for Services and Connections. 11. Expand SQLEXPRESS. 12. Click Service (see Figure 78 on page 49). Figure In the Service status field, verify that the service is running. If the service is not running, click Start. Also, if the service is running, but you made changes in the SQL Server Configuration Manager, click Stop, then click Start C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
50 14. Click Remote Connections (see Figure 79 on page 50). 15. Click Local and remote connections. 16. Click Using both TCP/IP and named pipes. 17. Click Apply. 18. Click SQL Server Browser. 19. Click Service. Figure In the Service status field, verify that the service is running. If the service is not running, select Automatic from the Startup Type drop-down list. Click "Apply", and then click "Start". 21. Click OK to close Surface Area Configuration for Services and Connections. Configuring Progeny Imaging to Use a Networked Database If you have chosen to network the Progeny Imaging database, you must configure the Progeny Imaging on each computer to use that networked database. You must restart the Progeny Imaging for this configuration to take effect. NOTE: Before Configuring Progeny Imaging to use a Database on the Network, Progeny Imaging on the server computer (or the computer designated to be the server) has to be installed, Progeny Imaging folder on that computer has to be configured to allow sharing, and the Progeny Imaging database has to be configured to be used on a network C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
51 To configure Progeny Imaging on a computer to Use a Database on the Network follow the steps bellow: 1. Select Tools > Options in Progeny Imaging (after log into Progeny Imaging). 2. In the Options screen, select the Database tab. 3. Select Networked to indicate that you are using a Progeny Imaging database that is located on another computer on the office network. 4. Click Find Servers and select the computer name that contains the Progeny Imaging database that you want to connect to. 5. Click Test for Database to verify that your computer can connect to the database. If the LED graphic on the Test for Database button turns green, then the computer you selected has an accessible Progeny Imaging database. 6. Before the change to the database takes effect, Progeny Imaging needs to restart. Click OK to restart Progeny Imaging. See "Database Tab" in the Progeny Imaging User's Guide C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
52 Section 9: Sensor Calibration in Progeny Imaging Each Vision DX 600 Series Sensor comes with an individual calibration file unique to the sensor s Serial Number. The calibration file must be installed before Progeny Imaging will recognize the sensor and prepare it to acquire images. To install the calibration file follow the steps bellow: 1. Open Progeny Imaging Software and log-in. In the top Tool Bar, find the Device Selection Menu. Select Default Vision DX USB (see Figure 80 on page 52). Figure When you select the Default Vision DX USB sensor from the Device Menu, the software will search for the sensor and its calibration file. 3. The Manage Vision DX Sensor Calibration File window will automatically open on your display (see Figure 81 on page 52). Figure Place the Calibration File CD for your sensor in to the CD/DVD drive of your PC now. 5. Click Add Calibration (see Figure 81 on page 52) C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
53 6. A new window will open (see Figure 82 on page 53). Figure Click the Browse Button (see Figure 82 on page 53) and navigate to My Computer. 8. Highlight the entry for Progeny Sensor (see Figure 83 on page 53). NOTE: Do not expand the file! 9. Click OK (see Figure 83 on page 53). Figure C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
54 10. The Navigation Window will close and the Progeny Sensor Serial Number will now appear in your New Sensor Calibration File Screen (see Figure 84 on page 54). 11. Click OK (see Figure 84 on page 54). Figure A confirmation Pop Up will appear on screen. Click Yes. 13. The configuration screen will close and return to the Manage Progeny Vision DX Sensor Calibration Menu. The Sensor Serial Number will now populate the screen and be highlighted in blue, and a green light will appear beside the Verify Calibration bar at the top of the menu. Click Close. Your Vision DX 600 Series Sensor is now ready to acquire images C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
55 Section 10: Configuring Progeny Imaging to Publish to a PACS Server Patient images acquired in Progeny Imaging can be published (sent) to a PACS server. In order to enable publishing to a PACS server, the PACS.xml file has to be edited with the information about the PACS server. NOTE: Set PACS.xml content on all computers with Progeny Imaging installed. NOTE: Communication with the PACS server is uni-directional. Progeny Imaging receives no return communication from the PACS server indicating that the images were received. When Progeny Imaging is installed, the PACS.xml file contains the lines shown below. If Progeny Imaging has previously been configured to send images to a PACS server, the PACS.xml file will contain values for the previously configured PACS server. <?xml version="1.0" encoding="utf-8"?> <PACS> <attribute ViewPublish="true" /> <attribute DServerIP=" " /> <attribute DTitle="PACS SERVER" /> <attribute DServerPort="2001" /> <attribute IsQuiet="true" /> <attribute IsSensitive="true" /> </PACS> Before Configuring PACS Publishing be sure that you know the IP address, port, and machine name of the PACS server. To Configure PACS Publishing follow the steps bellow: 1. Verify that <attribute ViewPublish="true" /> is set to true. 2. Change (or other IP address) in <attribute DServerIP=" " /> to the IP address of the PACS server where you intend to publish images. 3. Change PACS SERVER (or other PACS server name) in <attribute DTitle="PACS SERVER" /> to the machine name of the PACS server where you intend to publish images. 4. Change 2001 (or other port number) in <attribute DServerPort="2001" /> to the port number of the PACS server where you intend to publish images. 5. Verify that <attribute IsQuiet="true" /> is set to true. 6. Verify that <attribute IsSensitive="true" /> is set to true. 7. Save the xml file, but do not change the file name C 2009 Progeny 675 Heathrow Drive, Lincolnshire, IL 60008, U.S.A. Phone +1 (847)
Installation Guide v1.11 and Higher
Progeny Imaging Installation Guide v1.11 and Higher 00-02-1604 Rev. D ECN P3483 Revision Date: 6/2/2015 0120 Contents 1. About This Manual... 3 Text Conventions... 3 2. Welcome to Progeny Imaging... 4
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
LockView 4.2 CompX Database & Network Configuration & Installation Manual
LockView 4.2 CompX Database & Network Configuration & Installation Manual Table of Contents CompX Database & Network Configuration & Installation Manual Introduction... 4 Installation Requirements... 5
SOFTWARE INSTALLATION INSTRUCTIONS
AUDITGARD LGA Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS Implementation Package The AuditGard Software implementation package includes: 707013 AuditGard Software Install CD 42145 Programming/Audit
COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS
COMBOGARDPRO 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS IMPLEMENTATION PACKAGE The ComboGard Pro Software implementation package includes: 707012 ComboGard Pro Software Install
LockView 4.3.1 CompX Database & Network Configuration & Installation Manual
LockView 4.3.1 CompX Database & Network Configuration & Installation Manual Table of Contents CompX Database & Network Configuration & Installation Manual Introduction... 4 Installation Requirements...
Contents. Hardware Configuration... 27 Uninstalling Shortcuts Black...29
Contents Getting Started...1 Check your Computer meets the Minimum Requirements... 1 Ensure your Computer is Running in Normal Sized Fonts... 7 Ensure your Regional Settings are Correct... 9 Reboot your
Guide to Installing BBL Crystal MIND on Windows 7
Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP
A+ Guide to Software: Managing, Maintaining, and Troubleshooting, 5e. Chapter 3 Installing Windows
: Managing, Maintaining, and Troubleshooting, 5e Chapter 3 Installing Windows Objectives How to plan a Windows installation How to install Windows Vista How to install Windows XP How to install Windows
VERITAS Backup Exec TM 10.0 for Windows Servers
VERITAS Backup Exec TM 10.0 for Windows Servers Quick Installation Guide N134418 July 2004 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software
Magaya Software Installation Guide
Magaya Software Installation Guide MAGAYA SOFTWARE INSTALLATION GUIDE INTRODUCTION Introduction This installation guide explains the system requirements for installing any Magaya software, the steps to
Partner. Sage Pastel. Accounting. Installation Guide
Sage Pastel Accounting Partner Installation Guide Sage Pastel: +27 11 304 3000 Sage Pastel Intl: +27 11 304 3400 www.pastel.co.za www.sagepastel.com [email protected] [email protected] Sage Pastel Accounting
Network Setup Guide. Introduction. Setting up for use over LAN
Network Setup Guide This manual contains the setup information required to use the machine over wired LAN. If you use the machine with USB connection, refer to your setup sheet. Introduction To use the
Introduction 1-1 Installing FAS 500 Asset Accounting the First Time 2-1 Installing FAS 500 Asset Accounting: Upgrading from a Prior Version 3-1
Contents 1. Introduction 1-1 Supported Operating Environments................ 1-1 System Requirements............................. 1-2 Security Requirements........................ 1-3 Installing Server
Operating System Installation Guide
Operating System Installation Guide This guide provides instructions on the following: Installing the Windows Server 2008 operating systems on page 1 Installing the Windows Small Business Server 2011 operating
Installation Instruction STATISTICA Enterprise Server
Installation Instruction STATISTICA Enterprise Server Notes: ❶ The installation of STATISTICA Enterprise Server entails two parts: a) a server installation, and b) workstation installations on each of
Setup and Configuration Guide for Pathways Mobile Estimating
Setup and Configuration Guide for Pathways Mobile Estimating Setup and Configuration Guide for Pathways Mobile Estimating Copyright 2008 by CCC Information Services Inc. All rights reserved. No part of
Point of Sale 2015 Enterprise. Installation Guide
Point of Sale 2015 Enterprise Installation Guide Contents About this guide 3 System Requirements - Microsoft SQL Server 2008 R2 Express 3 System Requirements - POS Enterprise 2015 (Administrator) 3 System
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started Contents StrikeRisk v6.0 Introduction 1/1 1 Installing StrikeRisk System requirements Installing StrikeRisk Installation troubleshooting
FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version 2011.1
FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version 2011.1 2011 Sage Software, Inc. All rights reserved. Published by Sage 2325 Dulles Corner
Diamond II v2.3 Service Pack 4 Installation Manual
Diamond II v2.3 Service Pack 4 Installation Manual P/N 460987001B ISS 26APR11 Copyright Disclaimer Trademarks and patents Intended use Software license agreement FCC compliance Certification and compliance
Installation Notes for Outpost Network Security (ONS) version 3.2
Outpost Network Security Installation Notes version 3.2 Page 1 Installation Notes for Outpost Network Security (ONS) version 3.2 Contents Installation Notes for Outpost Network Security (ONS) version 3.2...
TANDBERG MANAGEMENT SUITE 10.0
TANDBERG MANAGEMENT SUITE 10.0 Installation Manual Getting Started D12786 Rev.16 This document is not to be reproduced in whole or in part without permission in writing from: Contents INTRODUCTION 3 REQUIREMENTS
InventoryControl for use with QuoteWerks Quick Start Guide
InventoryControl for use with QuoteWerks Quick Start Guide Copyright 2013 Wasp Barcode Technologies 1400 10 th St. Plano, TX 75074 All Rights Reserved STATEMENTS IN THIS DOCUMENT REGARDING THIRD PARTY
Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved.
Guest PC for Mac OS X Version 1.6 User Guide Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved. Table of Contents About Guest PC... 1 About your Virtual Computer... 1 Creating a Virtual
@ptitude Observer. Installation Manual. Part No. 32170700 Revision G
Part No. 32170700 Revision G Installation Manual Copyright 2012 by SKF Reliability Systems All rights reserved. Aurorum 30, 977 75 Lulea Sweden Telephone: +46 (0) 31 337 10 00, Fax: +46 (0) 920 134 40
Lexia Network Installation Instructions
Lexia Network Installation Instructions For Lexia Early Reading 3.x, Primary Reading 1.x, Foundation Reading 1.x, Strategies for Older Students 4.x, Cross-Trainer 1.x and Quick Reading Test 2.x (NOT for
GUARD1 PLUS SE Administrator's Manual
GUARD1 PLUS SE Administrator's Manual Version 4.4 30700 Bainbridge Road Solon, Ohio 44139 Phone 216-595-0890 Fax 216-595-0991 [email protected] www.guard1.com i 2010 TimeKeeping Systems, Inc. GUARD1 PLUS
Central Management System
Central Management System Software Installation Guide Ver. 1.5.0.101115.001 ... ii System Introduction... 3 Client/Server Architecture...3 System Requirements... 4 System Setup...4 Multiple Monitor Configuration...5
Table of Contents. 2 Getting Started Guide
Table of Contents Welcome... 3 Training & Support... 3 Accessing the online support center... 4 1. System Requirements... 5 2. Installing the Free Evaluation Version... 7 3. Software Download Instructions...
FedEx Ship Manager Software. Installation Guide
FedEx Ship Manager Software Installation Guide Before you start Check here to see that your PC has what it needs to run FedEx Ship Manager Software: Minimum System and Hardware Requirements Intel Pentium
Installation and Connection Guide to the simulation environment GLOBAL VISION
Installation and Connection Guide to the simulation environment GLOBAL VISION Hardware and Software Requirements The following hardware specification is recommended for client machines: 2 GHz Pentium class
Computer Requirements
Installing Pro64 Network Manager It is recommended that you quit all running Windows applications before starting the Aviom Pro64 Network Manager installation process. Check the Aviom website (www.aviom.com)
Installation Instruction STATISTICA Enterprise Small Business
Installation Instruction STATISTICA Enterprise Small Business Notes: ❶ The installation of STATISTICA Enterprise Small Business entails two parts: a) a server installation, and b) workstation installations
Getting Started with VMware Fusion
Getting Started with VMware Fusion VMware Fusion for Mac OS X 2008 2012 EN-000933-00 2 Getting Started with VMware Fusion You can find the most up-to-date technical documentation on the VMware Web site
Pearl Echo Installation Checklist
Pearl Echo Installation Checklist Use this checklist to enter critical installation and setup information that will be required to install Pearl Echo in your network. For detailed deployment instructions
ScanWin Installation and Windows 7-64 bit operating system
ScanWin Installation and Windows 7-64 bit operating system In order to run the ScanWin Pro install and program on Windows 7 64 bit operating system you need to install a Virtual PC and then install a valid,
STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS
STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS Notes 1. The installation of STATISTICA Enterprise Small Business entails two parts: a) a server installation, and b)
UNICORN 6.4. Administration and Technical Manual
UNICORN 6.4 Administration and Technical Manual Page intentionally left blank Table of Contents Table of Contents 1 Introduction... 1.1 Administrator functions overview... 1.2 Network terms and concepts...
STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS
Notes: STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS 1. The installation of the STATISTICA Enterprise Server entails two parts: a) a server installation, and b) workstation
How to Restore a Backup to Director V4.7x or greater
How to Restore a Backup to Director V4.7x or greater Restoring a Backup of the Director Database V4.7x or greater and then restoring it to a new PC See How to Backup Director V4.4x or greater.doc for details
AdminToys Suite. Installation & Setup Guide
AdminToys Suite Installation & Setup Guide Copyright 2008-2009 Lovelysoft. All Rights Reserved. Information in this document is subject to change without prior notice. Certain names of program products
Legal Notes. Regarding Trademarks. 2013 KYOCERA Document Solutions Inc.
Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from
Installation Instructions Release Version 15.0 January 30 th, 2011
Release Version 15.0 January 30 th, 2011 ARGUS Software: ARGUS Valuation - DCF The contents of this document are considered proprietary by ARGUS Software, the information enclosed and any portion thereof
VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide
VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide N109548 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software Corporation makes
USB 2.0 VGA ADAPTER USER MANUAL
USB 2.0 VGA ADAPTER USER MANUAL CONTENTS INTRODUCTION... 3 FEATURES... 3 SYSTEM REQUIREMENTS... 3 PACKAGE CONTENTS... 3 SUPPORTED COMMON DISPLAY RESOLUTION... 4 TECHNICAL SPECIFICATIONS... 4 INSTALLATION
UNICORN 7.0. Administration and Technical Manual
UNICORN 7.0 Administration and Technical Manual Page intentionally left blank Table of Contents Table of Contents 1 Introduction... 1.1 Administrator functions overview... 1.2 Network terms and concepts...
USB 2.0 3.5 External Hard Disk Drive
USB 2.0 3.5 External Hard Disk Drive System Requirements Notebook or Desktop PC with USB2.0 or USB1.1 port. Windows 98SE/Me/2000, or Windows XP (Make sure the device driver for USB Host controller has
MF Driver Installation Guide
English MF Driver Installation Guide User Software CD-ROM.................................................................. 1 About the Drivers and Software..................................................................
3.5 EXTERNAL NETWORK HDD. User s Manual
3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility
Installation Guide: Delta Module Manager Launcher
Installation Guide: Delta Module Manager Launcher Overview... 2 Delta Module Manager Launcher... 2 Pre-Installation Considerations... 3 Hardware Requirements... 3 Software Requirements... 3 Virtualisation...
Issue Tracking Anywhere Installation Guide
TM Issue Tracking Anywhere Installation Guide The leading developer of version control and issue tracking software Table of Contents Introduction...3 Installation Guide...3 Installation Prerequisites...3
Motorola Phone Tools. Quick Start
Motorola Phone Tools Quick Start Contents Minimum Requirements...2 Before Installing Motorola Phone Tools...3 Installing Motorola Phone Tools...4 Mobile Device Installation and Configuration...5 Online
Prerequisites Guide. Version 4.0, Rev. 1
Version 4.0, Rev. 1 Contents Software and Hardware Prerequisites Guide... 2 anterradatacenter Version selection... 2 Required Software Components... 2 Sage 300 Construction and Real Estate ODBC... 2 Pervasive
Mercy s Remote Access Instructions
Mercy s Remote Access Instructions ~~~~~~~~~~~~~~ Section A Windows 2000 / XP ~~~~~~~~~~~~~~ I. Install Meditech............................... A1 II. Install VPN Client............................. A3
3M Stats and Status Software for 3M Detection System Model 8900/9900. Administrator s Guide
3M Stats and Status Software for 3M Detection System Model 8900/9900 Administrator s Guide Copyright 2009, 3M. All rights reserved. 3M Stats and Status Software for 3M Detection System Model 8900/9900
Centran Version 4 Getting Started Guide KABA MAS. Table Of Contents
Page 1 Centran Version 4 Getting Started Guide KABA MAS Kaba Mas Welcome Kaba Mas, part of the world-wide Kaba group, is the world's leading manufacturer and supplier of high security, electronic safe
Core Protection for Virtual Machines 1
Core Protection for Virtual Machines 1 Comprehensive Threat Protection for Virtual Environments. Installation Guide e Endpoint Security Trend Micro Incorporated reserves the right to make changes to this
HP MediaSmart Server Software Upgrade from v.1 to v.3
HP MediaSmart Server Software Upgrade from v.1 to v.3 Table of Contents Upgrade Your Server Software to HP MediaSmart Server v.3 2 Before You Begin 3 What's New... 3 Features That Will Change... 4 Prepare
STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER
Notes: STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER 1. These instructions focus on installation on Windows Terminal Server (WTS), but are applicable
DOE VPN Client Installation and Setup Guide March 2011
DOE VPN Client Installation and Setup Guide March 2011 Table of Contents Introduction... 3 System Requirements... 3 Microsoft Windows... 3 Mac OS X... 4 Windows... 4 Installation for the Cisco AnyConnect
SYSTEM REQUIREMENTS...
Contents INTRODUCTION... 1 BillQuick HR Setup Checklist... 2 SYSTEM REQUIREMENTS... 3 HARDWARE REQUIREMENTS... 3 SOFTWARE REQUIREMENTS... 3 Operating System Requirements... 3 Other System Requirements...
HP MediaSmart Server Software Upgrade from v.2 to v.3
HP MediaSmart Server Software Upgrade from v.2 to v.3 Table of Contents Table of Contents Upgrade Your Server Software to HP MediaSmart Server v.3 2 Before You Begin 3 What's New 3 Features That Will
Keystone 600N5 SERVER and STAND-ALONE INSTALLATION INSTRUCTIONS
The following instructions are required for installation of Best Access System s Keystone 600N5 (KS600N) network key control software for the server side. Please see the system requirements on the Keystone
FortiVoice. Version 7.00 Start Guide
FortiVoice Version 7.00 Start Guide FortiVoice Version 7.00 Start Guide Revision 2 18 October 2011 Copyright 2011 Fortinet, Inc. All rights reserved. Contents and terms are subject to change by Fortinet
Installation Guide for Workstations
Installation Guide for Workstations Copyright 1998-2005, E-Z Data, Inc. All Rights Reserved. No part of this documentation may be copied, reproduced, or translated in any form without the prior written
Installing Windows XP Professional
CHAPTER 3 Installing Windows XP Professional After completing this chapter, you will be able to: Plan for an installation of Windows XP Professional. Use a CD to perform an attended installation of Windows
enicq 5 System Administrator s Guide
Vermont Oxford Network enicq 5 Documentation enicq 5 System Administrator s Guide Release 2.0 Published November 2014 2014 Vermont Oxford Network. All Rights Reserved. enicq 5 System Administrator s Guide
Iridium Extreme TM Satellite Phone. Data Services Manual
Iridium Extreme TM Satellite Phone Data Services Manual Table of Contents 1 OVERVIEW... 1 2 HOW IT WORKS... 1 3 BEFORE INSTALLING... 2 4 USB DRIVER INSTALLATION... 3 5 MODEM INSTALLATION AND CONFIGURATION...
Installing and Configuring vcenter Multi-Hypervisor Manager
Installing and Configuring vcenter Multi-Hypervisor Manager vcenter Server 5.1 vcenter Multi-Hypervisor Manager 1.1 This document supports the version of each product listed and supports all subsequent
SOS Suite Installation Guide
SOS Suite Installation Guide rev. 8/31/2010 Contents Overview Upgrading from SOS 2009 and Older Pre-Installation Recommendations Network Installations System Requirements Preparing for Installation Installing
Imaging Computing Server User Guide
Imaging Computing Server User Guide PerkinElmer, Viscount Centre II, University of Warwick Science Park, Millburn Hill Road, Coventry, CV4 7HS T +44 (0) 24 7669 2229 F +44 (0) 24 7669 0091 E [email protected]
Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1
Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...
**Please read this manual carefully before you use the product**
-1- **Please read this manual carefully before you use the product** Description: The CEB-2355S is a multifunction storage device designed in a special body structure, which can be simply connected to
SHARP Digital Signage Software Pro PN-SS05 OPERATION MANUAL
SHARP Digital Signage Software Pro PN-SS05 Version 4.1 OPERATION MANUAL Contents Introduction... 2 Precautions on Use...2 Trademarks...2 How to Read this Manual...3 Definitions...3 Installing/Launching...
for Windows 7 Laplink Software, Inc. Quick Start Guide h t t p : / / w w w. l a p l i n k. c o m / h e l p MN-LLG-EN-15 (REV.
1 for Windows 7 Laplink Software, Inc. Customer Service/Technical Support: Web: http://www.laplink.com/help E-mail: [email protected] Laplink Software, Inc. 14335 NE 24th Street, Suite 201 Bellevue,
Symantec Backup Exec 12.5 for Windows Servers. Quick Installation Guide
Symantec Backup Exec 12.5 for Windows Servers Quick Installation Guide 13897290 Installing Backup Exec This document includes the following topics: System requirements Before you install About the Backup
Interworks. Interworks Cloud Platform Installation Guide
Interworks Interworks Cloud Platform Installation Guide Published: March, 2014 This document contains information proprietary to Interworks and its receipt or possession does not convey any rights to reproduce,
Enterprize Setup Checklist
Enterprize Setup Checklist Corporate Server 1) Install Windows IIS and FTP 2) Install M$ MSDE Restart Windows 3) Install M$ Image Wizard 4) Install Enterprize Copy SQL databases into Microsoft SQL data
INSTALLATION AND UPGRADE
1 INSTALLATION AND UPGRADE This chapter will explain how to install PastPerfect on a single computer or a network. It will also show you how to load data from an older version of PastPerfect. At the end
IMPORTANT! CPD 8424R1
IMPORTANT! You need to reinstall EPSON Image Authentication System (IAS) on your camera if it was installed before your camera was repaired. Please see your EPSON Image Authentication System User s Guide
Imaging License Server User Guide
IMAGING LICENSE SERVER USER GUIDE Imaging License Server User Guide PerkinElmer Viscount Centre II, University of Warwick Science Park, Millburn Hill Road, Coventry, CV4 7HS T +44 (0) 24 7669 2229 F +44
VirtualXP Users Guide
VirtualXP Users Guide Contents Chapter 1: Introduction... 2 Chapter 2: Install and Uninstall VirtualXP... 3 2.1 System Requirement... 3 2.2 Installing VirtualXP... 3 2.3 Uninstalling VirtualXP... 3 Chapter
Sage ERP MAS 90 Sage ERP MAS 200 Sage ERP MAS 200 SQL. Installation and System Administrator's Guide 4MASIN450-08
Sage ERP MAS 90 Sage ERP MAS 200 Sage ERP MAS 200 SQL Installation and System Administrator's Guide 4MASIN450-08 2011 Sage Software, Inc. All rights reserved. Sage, the Sage logos and the Sage product
Installation Guide Sybase ETL Small Business Edition 4.2 for Windows
Installation Guide Sybase ETL Small Business Edition 4.2 for Windows Document ID: DC00738-01-0420-01 Last revised: April 2007 Topic Page 1. Overview 2 2. Before you begin 2 2.1 Review system requirements
http://docs.trendmicro.com
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the product, please review the readme files,
This document describes the standard software installation process for Doors.NET software.
Doors.NET installation and controller configuration is a three step process. Each of these steps has its own document, with controller configuration broken into separate documents per hardware type. software
Table of Contents. Introduction...9. Installation...17. Program Tour...31. The Program Components...10 Main Program Features...11
2011 AdRem Software, Inc. This document is written by AdRem Software and represents the views and opinions of AdRem Software regarding its content, as of the date the document was issued. The information
DOCSVAULT Document Management System for everyone
Installation Guide DOCSVAULT Document Management System for everyone 9 v Desktop and Web Client v On Premises Solution v Intelligent Data Capture v Email Automation v Workflow & Record Retention Installing
BillQuick Agent 2010 Getting Started Guide
Time Billing and Project Management Software Built With Your Industry Knowledge BillQuick Agent 2010 Getting Started Guide BQE Software, Inc. 2601 Airport Drive Suite 380 Torrance CA 90505 Support: (310)
APNT#1209 Using GP-Pro EX in Windows 7 XP Mode. Introduction. Prerequisites. Licensing and availability of XP Mode
Application Note #1209: Using GP-Pro EX in Windows 7 XP Mode Introduction IMPORTANT NOTE: GP-Pro EX v3.0 and later is supported on 32 and 64 bit Windows 7. We recommend upgrading to the latest version
How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The
1-bay NAS User Guide INDEX Index... 1 Log in... 2 Basic - Quick Setup... 3 Wizard... 3 Add User... 6 Add Group... 7 Add Share... 9 Control Panel... 11 Control Panel - User and groups... 12 Group Management...
File Management Utility. T u t o r i a l
File Management Utility T u t o r i a l Contents System Requirements... 2 Preparing Files for Transfer to GlobalMark... 2 Application Launch... 2 Printer Setup... 2 Communication Status... 4 Communication
Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual
Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual Installing a hard disk 1. Power off the unit. 2. Remove the bottom cover from the unit by removing four screws. 3. Insert the 2.5 HDD to the
2014 Electrical Server Installation Guide
2014 Electrical Server Installation Guide TITLE: 2014 Electrical Server Installation Guide DATE: September 2013 SUBJECT: ABSTRACT: Installation guide for SolidWorks Electrical 2014 on the server Guide
WhatsUp Gold v16.1 Installation and Configuration Guide
WhatsUp Gold v16.1 Installation and Configuration Guide Contents Installing and Configuring Ipswitch WhatsUp Gold v16.1 using WhatsUp Setup Installing WhatsUp Gold using WhatsUp Setup... 1 Security guidelines
How to Install a Business Internet Video Camera
Package Contents 2300 Series Camera Stand Kit Power Supply (12V 1A) 6 Ethernet Cable Lens Adapter Ring Allen Wrench Quick Installation Guide Setup CD Antenna (WVC2300) Business Internet Video Camera with
intertrax Suite resource MGR Web
intertrax Suite resource MGR Web Resource Management Installation Guide Version 4 2012 Copyright 2003-2012 by Salamander Technologies, Inc. Protected by US Patents 5,573,278; 5,596,652; 5,793,882; 6,761,312;
3M Occupational Health and Environmental Safety 3M E-A-Rfit Validation System. Version 4.2 Software Installation Guide (Upgrade) 1 P age
3M Occupational Health and Environmental Safety 3M E-A-Rfit Validation System Version 4.2 Software Installation Guide (Upgrade) 1 P age Contents Important Information Read First... 3 Software Download...
Chapter 1 Downloading Images to Your Computer (Windows)
Software User Guide For the safe use of your camera, be sure to read the Safety Precautions thoroughly before use. Types of software installed on your computer varies depending on the method of installation