Firestone Warranty Program
|
|
|
- Blaise Wilson
- 9 years ago
- Views:
Transcription
1 EPDM Warranty Pricing ***For Red Shield Contractors Only*** Red Shield 20 Years $0.10 $ No Dollar Limit 15 Years $0.07 $ No Dollar Limit 10 Years $0.04 $ No Dollar Limit When Firestone ISO 95+ is not used 5 Years $0.02 $ No Dollar Limit When Firestone ISO 95+ is used.. 5 Years $300 Flat Fee N/A No Dollar Limit Platinum P 30 Years $0.15 $1,000 No Dollar Limit Platinum PH 30 Years $0.15 $1,000 No Dollar Limit Platinum PHW 30 Years $0.15 $1,000 No Dollar Limit Membrane Only 20 Years N/A $200 Pro-rated 10 Years N/A $50 Pro-rated
2 UltrayPly TPO & UltraPly 78+ (PVC) Warranty Pricing ***For Red Shield Contractors Only*** Red Shield 20 Years $0.10 $500 No Dollar Limit 15 Years $0.07 $400 No Dollar Limit 10 Years $0.04 $350 No Dollar Limit When Firestone ISO 95+ is not used 5 Years $0.02 $300 No Dollar Limit When Firestone ISO 95+ is used.. 5 Years $300 Flat Fee N/A No Dollar Limit Membrane Only 20 Years N/A $200 Pro-rated 15 Years N/A $100 Pro-rated 10 Years N/A $50 Pro-rated
3 Asphalt Systems Warranty Pricing SBS, APP, & BUR Systems ***For Red Shield Contractors Only*** Red Shield 20 Years $0.10 $500 No Dollar Limit 15 Years $0.07 $400 No Dollar Limit 12 Years $0.06 $400 No Dollar Limit 10 Years $0.04 $350 No Dollar Limit When Firestone ISO 95+ is not used 5 Years $0.02 $300 No Dollar Limit When Firestone ISO 95+ is used.. 5 Years $300 Flat Fee N/A No Dollar Limit For 2-ply modified bitumen systems, regardless of area Any $500 Flat Fee N/A No Dollar Limit Asphalt Systems Standard Warranty Pricing SBS, APP, & BUR Systems ***For Red Shield Or Registered Contractors*** Standard 15 Years $0.08 $400 Original (Registered Contractors must pay for 12 Years $0.06 $400 Installed Cost of warranty fee prior to inspection.) 10 Years $0.05 $350 MB or BUR 5 Years $0.03 $300 System MB Membrane 10 Years N/A $50 Orig. Installed Cost of 12 Years N/A $50 MB Membrane MB Product 10, 12 or 15 Years No Charge N/A Pro-rated Material Ply Sheet Material 10 Years No Charge N/A Pro-rated Material
4 ISO 95+ Warranty Pricing (Available only in conjunction with a Red Sheild Roof System Warranty of same coverage period.) Manufacturer's Insulation Warranty 5 Years No Charge No Charge No Dollar Limit (Only Red Shield Contractors Eligible) 10 Years No Charge No Charge No Dollar Limit 15 Years No Charge No Charge No Dollar Limit 20 Years No Charge No Charge No Dollar Limit
5 Extended Wind Speed Coverage EPDM, TPO, SBS, APP, & Built-up Systems (Available with Red Shield System Warranties Only) Extended Wind Speed Warranties require each system to be reviewed by Firestone Roofing Solutions prior to bidding a project. Some systems may not be eligible for additional coverage, and others may require significant modifications. Always contact your Firestone Technical Coordinator to discuss the details of a particular project. Warranty Type Max. Wind Price Per Minimum Monetary Ballast Speed Sq. Ft. Charge Limitation Paver Warranty 10 Year Red Shield 72 mph $0.04 $350 No Dollar Limit $0.08 (Only Red Shield Contractors Eligible) 80 mph $0.05 $700 No Dollar Limit $0.09 Contact Firestone Roof Solutions for specific 90 mph $0.06 $800 No Dollar Limit $0.10 requirements 100 mph $0.07 $900 No Dollar Limit $ mph $0.08 $1000 No Dollar Limit $ mph $0.09 $1100 No Dollar Limit $ mph** NA NA No Dollar Limit $ mph** NA NA No Dollar Limit $ mph** NA NA No Dollar Limit $ Year Red Shield 72 mph $0.07 $400 No Dollar Limit $0.17 (Only Red Shield Contractors Eligible) 80 mph $0.08 $1200 No Dollar Limit $0.18 Contact Firestone Roof Solutions for specific 90 mph $0.10 $1300 No Dollar Limit $0.19 requirements 100 mph $0.11 $1400 No Dollar Limit $ mph $0.13 $1500 No Dollar Limit $ mph $0.15 $1600 No Dollar Limit $ mph** NA NA No Dollar Limit $ mph** NA NA No Dollar Limit $0.24
6 Firestone International Warranty Program Warrantability of projects outside of the United States and Canada must be submitted to Firestone Technical Services Department for consideration prior to bidding. Firestone will not consider issuing warranties for projects in locations where local Red Shield Contractors are not available for service. Red Shield 15 Years $0.09 $400 No Dollar Limit 10 Years $0.05 $350 No Dollar Limit When Firestone ISO 95+ is not used 5 Years $0.03 $300 No Dollar Limit When Firestone ISO 95+ is used.. 5 Years $500 Flat Fee N/A No Dollar Limit Membrane Only 20 Years N/A $200 Pro-rated 10 Years N/A $50 Pro-rated
7 Re-Inspection Charges Inspections to Re-instate Warranty Coverage Interim Inspections as required by owner or contract Warranty Corrections Warranty Transfers Special Warranties Firestone Warranty Program Other Warranty Charges (US$) $500 per day plus travel expenses for 3rd and subsequent inspections. $500 per day plus travel expenses $500 per day plus travel expenses $50 for minor corrections requiring re-issuance. $ for 2nd change and changes thereafter. $75 administrative fee. If inspection is required, $500 per day plus travel expenses for all projects up to 50,000 square feet. Projects over 50,000 square feet are charged at $.01 per square foot. Minimum $.01 per square foot over Red Shield price for same length. Check with Firestone Contractor Services for exact pricing.
Prices Effective April 1, 2016
Domestic U.S. Warranty Pricing Guide Longer term warranties have additional installation requirements and not all warranty terms are available for all roofing specifications. Please refer to the Firestone
Best Practices in Roof Design: Sustainable Energy Efficient Reroofing
Best Practices in Roof Design: Sustainable Energy Efficient Reroofing Best Practice Roof Design: Sustainable Energy Efficient Reroofing Presented by Edis Oliver, PE Principal 9511 Lake Creek Parkway Austin,
Roof Inspection and Evaluation
Roof Inspection and Evaluation Sylvester Powell Community Center 6200 Martway Mission, KS 66202 Prepared For: Your name Sample Community Center 6200 Martway Mission, KS 66202 Kansas City, MO 64105 200
Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION
HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION David Marut TEST CASE REPORT July 1, 2014 Case Study Pro Guard EPDM Super Coat Liquid Rubber Membrane Roof System
COMMERCIAL ROOFING. Learning Objectives. Commercial Roofing Fundamentals May 2, 2012
COMMERCIAL ROOFING The Fundamentals Firestone Building Products is a Registered Provider with the American Institute of Architects Continuing Education Systems. Credit earned on completion of this program
The Building Group First Tuesdays First Saint Paul s Lutheran Church 1301 North LaSalle Street, Chicago, Illinois
Wiss, Janney, Elstner Associates, Inc. 10 South LaSalle Street, Suite 2600 Chicago, Illinois 60603 312.372.0555 tel 312.372.0873 fax www.wje.com The Building Group First Tuesdays October 2, 2012 Jason
COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE
www.epdmroofs.org COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE By Ric Vitiello President Forensic Roof Consulting and Hail Damage Assessment Training www.benchmark-services.com
!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!
Table of Contents Section 1: Most Common Types of Flat Roofing Section 2: Better Understand Your Flat Roof Section 3: Flat Roofing Cost in 2015: Four Factors that Dictate Section 4: Planning A Flat Roofing
16 2 10.3 Materials and Colors
16 2 10.3 Materials and Colors To create a harmonious and coherent image for each development, building designs shall pay close attention to choice of materials and colors. Building construction shall
Roofing & Waterproofing Forensics for the 21 st Century. Peter Brooks, President
Roofing & Waterproofing Forensics for the 21 st Century Peter Brooks, President March 20, 2013 ICRI Spring Convention Selecting the Appropriate Non-Destructive Testing Technology What is the Goal? Methodologies:
Guideline for Construction Reimbursement Rates. 160-5-4-.16 (a) 7. Educational Facility Site, Construction, and Reimbursement
Guideline for Construction Reimbursement Rates 160-5-4-.16 (a) 7 Educational Facility Site, Construction, and Reimbursement Facilities Services Unit Effective Date: 05-30-12 NEW CONSTRUCTION REIMBURSEMENT
Roof Inspection Report 3840 Greenway Circle, Lawrence Kansas, 66046 Sauer-Danfoss Building
Roof Inspection Report 3840 Greenway Circle, Lawrence Kansas, 66046 Sauer-Danfoss Building Prepared For: Ms Marilyn Bittenbender Colliers International 805 New Hampshire St Lawrence Kansas, 66046 Prepared
Get Rid of Roof Problems for Good. How spray foam roofing can protect your building and make you money
Get Rid of Roof Problems for Good How spray foam roofing can protect your building and make you money What is a Spray Foam Roofing System? 300 MILLION Board feet of roofing spray foam installed annually
THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS
OPTIONAL TITLE 24 CRITICAL POINTS POLYISO THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE DESCRIPTION TORCH OVER POLYISO (5,7,9 YR) TH/BS-TH/CS 2 No 0. SUBSTRATE. THERMOTEK USA PRO 2.0 FV
Building Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
Roofing Systems. New Applications / Re-Roofing / Maintenance
Roofing Systems New Applications / Re-Roofing / Maintenance New Roof Installation In terms of the design and installation of an original roofing system (in conjunction with the construction of a new building),
THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER
THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER DESCRIPTION TORCH OVER (15,17,19 YR) TH/BS-TH/CS 2 1 0 No 0. SUBSTRATE 1. THERMOTEK USA 2.0 FV TORCH SMOOTH 2. THERMOTEK USA PRO FP TORCH GRANULE COMPONENTS
Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY
Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded
ROOFING CONTRACTORS QUESTIONNAIRE
ROOFING CONTRACTORS QUESTIONNAIRE ALL QUESTIONS MUST BE ANSWERED 1. Applicant Name: Website Address: Address: Years in business under the applicant name: Are you an NRCA (National Roofing Contractors Association)
BUSI 441 Project 1: Reserve Fund Study
BUSI 441 Project 1: Reserve Fund Study Estimating Roofing Replacement Cost In Project 1, Part One, section (b) you are instructed to identify the roofing type and area for your subject building. The section
Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE
Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE I n t r o d u c t i o n t o M o d i Acres of Roofing. Decades of Performance. Over the past 20 years, Firestone Building Products
UL Online Certifications Directory
UL Online Certifications Directory Home Quick Guide Contact Us UL.com TGFU.R11183 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems PACTIV CORP SUITE 175 2100 RIVEREDGE
Roof Condition Analysis
Roof Condition Analysis Prepared for: J.W. Nelson John Evans Middle School - Gym Dome 2900 15th Avenue Greeley, Colorado Prepared by: Gregory Ham Coastal Specified Products 5252 Sherman Street Denver,
SchoolRoof Repair - Cost For Replacement of a Student Roof, Part 2
ROOF REPAIR UPDATE For the November school newsletter, I wrote an article in which I explained the condition of the school roof, the estimated cost of replacing the three flat sections from the 1996 building
The Harold J. Becker Company, Inc.
The Harold J. Becker Company, Inc. It is the mission of The Harold J. Becker Company, Inc. to deliver the absolute best possible quality product at the most efficient cost to our clients, while providing
BUILDING PERMITS. Santa Rosa County Building Inspection
BUILDING PERMITS Calculation Based on Under Roof Area New Construction First 5,000 sq. ft. Each additional hundred sq. ft. up to 10,000 sq. ft. Each additional hundred sq. ft. up to 25,000 sq. ft. Each
Construction Management At-Risk
Oconee County Schools P.O. Box 146, 34 School Street Watkinsville, GA 30677 706-769-5130 706-769-3513 REQUEST FOR PROPOSALS ISSUE DATE: March 10, 2016 RFP REF: Construction Management At-Risk Construction
ANSI/SPRI WD-1 Wind Design Standard Practice for Roofing Assemblies. Table of Contents. 1.0 Introduction...2. 2.0 Methodology...2
Standard Practice f Table of Contents 1.0 Introduction...2 2.0 Methodology...2 Appendix A...7 Insulation Board Fastening Patterns 4 feet 4 feet Boards Adhered Membranes...8 Insulation Board Fastening Patterns
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
ROOFING CONTRACTOR SUPPLEMENTAL APPLICATION
CoverX The Coverage Experts www.coverx.com Producer: Producer Is: Wholesaler Retailer Address: Telephone: Fax: Excess & Surplus Lines License No.: Email: Proposed Effective Date: If Renewal, Provide Current
SECTION 07550 - MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.
SECTION 07550 - PART I GENERAL 1.01 SECTION INCLUDES A. Vapor barrier (base ply); cover board at existing roof deck. B. Roof insulation at new roof deck. C. Modified bitumen membrane. D. Fluid applied
Roof Restoration System. For building owners, property management firms and facility managers. seamless possibilities
Roof Restoration System For building owners, property management firms and facility managers seamless possibilities Extending your roof life Think of your existing older roof custom fit with a seamless,
How To Know If A Reflective Roofmembrane Is More Efficient
Wiss, Janney, Elstner Associates, Inc. 9511 North Lake Creek Parkway Austin, Texas 78717 512.257.4800 tel 512.219.9883 fax Texas Registered Engineering Firm F-0093 www.wje.com Sustainable Energy Efficient
DISTRICT OF BARRIERE REQUEST FOR PROPOSAL
DISTRICT OF BARRIERE REQUEST FOR PROPOSAL SUPPLY AND INSTALLATION OF FLAT ROOF SYSTEM AND RELATED REPAIRS RFP No. 2014-02 1. SUMMARY OF REQUIREMENT The District is planning on reroofing the existing flat
THE EFFECT OF REFLECTIVE ROOF COATINGS ON THE DURABILITY OF ROOF SYSTEMS
THE EFFECT OF REFLECTIVE ROOF COATINGS ON THE DURABILITY OF ROOF SYSTEMS Joseph W. Mellott II and Donald C. Portfolio ROOF COATING MANUFACTURERS ASSOCIATION International Roofing Expo TU-03 Technical March
THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS
THERMOTEK SELF ADHESIVE MEMBRANE +G OVER DESCRIPTION SELF ADHESIVE OVER (8YR) BS-SA/CS 1 0 No 0. SUBSTRATE 1. BASE SHEET G FIBER GLASS BASE. THERMOTEK SELF ADHESIVE 3.0 FP GRANULE COMPONENTS AND WEIGHTS
HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION
HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION ADVANCED TECHNOLOGY FROM OWENS CORNING TRUMBULL ASPHALT TruLo Lo Odor and TruLo Max asphalt raising the roof on asphalt performance.
41 Dogwood Road, Asheville, NC 28806 866-567-2064 f 828-258-7769 naroofing.com [email protected]
WELCOME. To the most trusted & respected roofing company in the U.S. 41 Dogwood Road, Asheville, NC 28806 866-567-2064 f 828-258-7769 naroofing.com [email protected] OUR COMPANY Since 1979, North American
Roofing Sustainability
Williams Engineering Canada Inc. Roofing Sustainability Gord Rajewski R.E.T. November 19, 2009 Overview History of Williams Engineering Canada Who WE are today Roofing 101 Low slope (flat) roofs Sloped
Nondestructive Evaluation of USCG. 2401 Hawkins Pt. Road Curtis Bay, MD 21226. Provided by: HurleyIR
Nondestructive Evaluation of USCG 2401 Hawkins Pt. Road Curtis Bay, MD 21226 Provided by: HurleyIR On Tuesday May 20 th 2014, HurleyIR provided a nondestructive evaluation for Ruff Roofers of the USCG
Crescent Valley High School Roof Investigation
Crescent Valley High School Roof Investigation Project: Corvallis School District Crescent Valley High School Roof Date: July 26, 2011 Report By: Rowell Brokaw Architects: Mark Young, AIA, Chris Andrejko
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT NCE Table Application Type Description Page 1A-1 Wood New, Reroof (Tear-Off), Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 4 1A-2
Predictive Service Life Tests for Roofing Membranes
Predictive Service Life Tests for Roofing Membranes ABSTRACT C.G. Cash, D.M. Bailey, A.G. Davies, Jr., A. H. Delgado, D.L. Niles, R.M. Paroli Simpson Gumpertz & Heger Inc, Waltham, MA USA U.S. Army Corps
REQUEST FOR QUOTATION RFQ-FH-08-09-10118 ROOF REPAIR
DEPARTMENT OF CENTRAL SERVICES REQUEST FOR QUOTATION RFQ-FH-08-09-10118 ROOF REPAIR 1. GENERAL CONDITIONS A. The City of Farmington Hills DPW is requesting quotes to repair the existing flat roof on the
Proven roofing SyStemS
Proven Roofing Systems Above all. Roofing challenges are never over our heads At GenFlex, we live to tackle and solve the toughest challenges in roofing. The result is a full line of proven, durable roofing
FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association
FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING Roofing Manufacturers Association Why is a built-up roof considered a multi-ply roof? ARMA defines a built-up roofing system as a roof where multiple
CITIZENS PROPERTY INSURANCE CORPORATION BUILDING TYPE II AND III MITIGATION VERIFICATION AFFIDAVIT
CITIZENS PROPERTY INSURANCE CORPORATION BUILING TYPE II AN III MITIGATION VERIFICATION AFFIAVIT This affidavit must be completed to capture mitigation features applicable to a Type II (4 to 6 story) or
Proper roof slope and drainage are important to prevent excessive water accumulation
Proper roof slope and drainage are important to prevent excessive water accumulation by Jason P. Wilen, AIA, CDT, RRO P onding water sometimes occurs on membrane roof systems as a result of snow, rainfall
CITIZENS PROPERTY INSURANCE CORPORATION. STREET ADDRESS: 14300 Gulf Blvd, Maderia Beach, FL 33708 6 Six story masonry residence
CITIZENS PROPERTY INSURANCE CORPORATION BUILDING TYPE II AND III MITIGATION VERIFICATION AFFIDAVIT This affidavit must be completed to capture mitigation features applicable to a Type II (4 to 6 story)
Koppers, Versico, DuroLast & Johns coal tar pitch, single ply systems incl. EPDM, TPO, PVC on new const or existing buildings.
Esko Roofing & Sheet Metal Schena Roofing & Sheet Metal Co Inc Newton Crane Roofing Inc CEI Michigan LLC 14000 Simone 28299 Kehrig Drive 353 N Cass Ave PO Box 200 Shelby Twp MI 48315 Chesterfield MI 48047
ROOFING CONTRACTOR SUPPLEMENTAL APPLICATION
SEND SUBMISSIONS TO: [email protected] www.coverx.com Producer: Producer Is: Wholesaler Retailer Address: Telephone: Fax: Excess & Surplus Lines License No.: Email: Proposed Effective Date: If Renewal,
The Assumptions. By Howard P. Weisz, President HW Associates
YOU ARE PROBABLY PAYING TOO MUCH FOR YOUR THIRD PARTY WAREHOUSING -- OR, WHEN YOU NEGOTIATE RATES, YOU SHOULD ONLY BE NEGOTIATING YOUR 3PL PROVIDER S PROFIT! By Howard P. Weisz, President HW Associates
+1.877.497.3528 [email protected] www.grscanadainc.com
WORK ORDER AGREEMENT I. Work Site Documentation Quotation / Bid # Core Samples / Infrared Purchase Order # Consultant Report Start Date: II. Work Site Address Building Name Street City Province Postal
CITY OF BAYTOWN Building Inspections
CITY OF BAYTOWN Building Inspections PERMIT SCHEDULE Residential Building Permit Fees Sec. 18-127. (a) Any person applying to the city for a building permit shall pay to the city, prior to the issuance
Rooftop Matters. 2 0 1 2 Benchmark Report. Executive Summary
The 2012 Benchmark Report is our initial survey covering results from roof inspections and service calls over a six-month period. Our intention is to update these results annually in order to provide meaningful
Solicitation DTFACN-11-R-00079 Attachment #9
These specs are only a general overview of the typical VOR Roof construction. These are for reference only. Each individual project will have its own specifications. 1 VOR Roof Projects IDIQ Solicitation
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC
Commercial Fee estimate The Building department will provide the actual fees at the time the permit is issued.
1. Determine the occupancy, type of construction, and floor area (square footage) Commercial Fee estimate The Building department will provide the actual fees at the time the permit is issued. 2. Determine
Frequently Asked Questions Concerning the Public Bidding and Prevailing Wage Requirements of New Jersey Charter Schools
Frequently Asked Questions Concerning the Public Bidding and Prevailing Wage Requirements of New Jersey Charter Schools 1. Are charter schools required to comply with New Jersey public bidding requirements
0845 0098 980 www.nicholsonsts.com
0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution
Entergy Arkansas, Inc. 2015 Home Energy Solutions FAQs & Program Summary
2015 Home Energy Solutions FAQs & Program Summary PREPARED BY: CLEAResult Contact the Energy Efficiency Solutions Center at (877) 212-2420 Email: HomeEnergySolutionsEAI@CLE AResult.com Revision Date: 1/12/2015
Commercial Roofing Division
Commercial Roofing Division Protecting your business is our business! 2000 squares of shingles (30yr architect) Brentwood Condominiums Atlanta, Georgia RRSA s success is built on Founder Grady Marty Haight
Tile Tech Pavers Paving America one step at a time.
Tile Tech Pavers Paving America one step at a time. MANUFACTURER OF PEDESTAL PAVER SYSTEM 2 P e d e s t a l S y s t e m - A p p l i c a t i o n The concept of using concrete pavers as roof ballast, plaza
REQUEST FOR PROPOSALS
Page 1 of 6 REQUEST FOR PROPOSALS Issue Date: 2/19/2013 RFP# WHS-2013-001 Title: Services for roofing improvements and annual roof assessments, Windsor School Complex, State Street, Windsor, Vermont Issuer
Property Policyholder Risk Improvement Report and Hurricane Survey
Risk Engineering Property Policyholder Risk Improvement Report and Hurricane Survey Zurich Services Corporation Risk Engineering 1400 American Lane Schaumburg, IL 60196-1056 847.605.6000 Fax: 847.605.7854
REQUEST FOR QUALIFICATIONS/PROPOSAL (RFQ/P) FOR A ROOF CONSULTANT
REQUEST FOR QUALIFICATIONS/PROPOSAL (RFQ/P) FOR A ROOF CONSULTANT Durango School District 9 R (Owner) 201 East 12 th Street Durango, Colorado 81301 Phone (970) 247 5411, ext. 1458 PROPOSAL DUE DATE/DELIVERY
Firestone SBS Modified Bitumen Roofing System Design and Application Guide
SBS Modified Bitumen Roofing System Design and Application Guide October, 2013 Table of Contents 1.01 Introduction... 1 1.01.1.1 General Considerations... 1 1.01.1.2 Warranty... 3 1.01.1.3 QUALITY ASSURANCE...
Site Inspection Report
Site Inspection Report Project Title: 1 Canada Square Location: 1 Canada Square, Canary Wharf, London Date of Inspection: 16/05/12 System / Products: TBA (suggested flame free application) Attendees: G
Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS
AC TOPSEAL SELF-ADHERED, GRANULAR SURFACED, SINGLE PLY, LOW SLOPE ROLLED ROOFING 3 X 33.3 = 100 SQ. FT. 10 YEAR MATERIAL LIMITED WARRANTY For Use on Porches / Sheds / Utility Buildings / Accessory Buildings
Clark roofing www.clarkroofing.ca
CLARK ROOFING www.clarkroofing.ca 2 CONSTRUCTION Clark Roofing 2 Quality r for over 40 OCTOBER 2010 The Canadian Business Journal CB 3 CONSTRUCTION roofing years Clark Roofing 4 CONSTRUCTION Clark Roofing
w www.kyschooldesigns.org
w www.kyschooldesigns.org A collaborative project of AIA Kentucky, Kentucky School Boards Association, Kentucky Association of School Superintendents, Kentucky Association of School Administrators Name
Roof Inspection. Summary Report
Phone: (561) 866 9956 www.real-estate-inspections.com Roof Inspection Summary Report Subject Property File Number: 05-15-RF-002 Inspector: Craig Milliken, PE CPM Real Estate Inspections, Inc. Date of Inspection:
Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5
Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,
CITY OF PLANO BUILDING INSPECTION FEE SCHEDULE. Initial Deposit/Fees are due at the time of the submittals. Effective 03/01/10
CITY OF PLANO BUILDING INSPECTION FEE SCHEDULE Initial Deposit/Fees are due at the time of the submittals. Effective 03/01/10 A. Access Control $5.25/$1000.00 valuation of project Electric (if applicable)
CREEK Technical Services, LLC
EVALUATION REPORT 2010 FLORIDA BUILDING CODE Manufacturer: Henry Company Report Issued February 20, 2013 999 North Sepulveda Blvd., Suite 800 El Segundo, CA 90245 (800) 486-1278 Manufacturing Plants: Quality