VISION UPS UPS PRODUCT CATALOGUE
|
|
|
- Clyde Newton
- 10 years ago
- Views:
Transcription
1 VISION UPS UPS PRODUCT CATALOGUE
2 VISION UPS Systems S. à r. l. About VISION UPS VISION UPS SYSTEMS S. à r. l. was established in 2003 by the two belgian UPS-specialists Patrick Willems and Ralph Collas based on the expierence which was gained in the course of 20 years work in the UPS sector. Contents Contents About VISION UPS 03 3 UPS technologies 04 Technical problems and VISION solutions 05 Fields of application 06 Product overview 08 VISION UPS quickly gained currency on four continents and is at the present day a worldwide appreciated manufacturer of UPS and AC and DC systems. Equipment made by VISION UPS demonstrates its quality and reliability not only in Europe but also under severe conditions in Africa and Asia. In 2009 VISION UPS established its representation in Russia, which is concerned with support service for customers in Eastern Europe and Asia.. v Line-interactive UPS (1/1phase, VA) Budget Pro square wave 10 Budget square wave 12 Pro Blue square wave 14 Jupiter Pro sine wave 16 Jupiter XL sine wave 18 Online UPS (1/1 and 3/1phase, 1-20kVA) Spirit tower 20 Spirit XL tower-rackmount 22 Vision LCD tower 24 Vision XL tower-rackmount 26 Vision XL II tower-rackmount 28 Vision II (+) tower 1/1 and 3/1 30 The philosophy of VISION European quality for the best price Shortest delivery time Individual solutions in cooperation with the customer Wide product range Unique products for your requirements Service and training center in Luxembourg Online UPS 3/3phase (10-300kVA) Premium DSP (+/++) 32 Premium Long backup time (1/1 and 3/1phase, 800VA-200kVA) Marathon tower 36 Marathon XL tower-rackmount 38 Marathon + with galvanic isolation 40 Marathon 3/3 three-phase UPS 42 Modular UPS (3/3-3/1-1/1phase) Vision MOD (3/1-1/1phase) 44 Vision MOD (3/3 phase) 46 Individual solutions, options and monitoring 48 Service and warranty 52 References 53 XL - tower and rackmount version "2 in 1" + - with galvanic isolation transformer for phase ++ - with galvanic isolation transformer for phase and neutral II - allows parallel connection (up to 4 units) 2 3
3 3 UPS Technologies Technical problems VISION solutions OFF-LINE TECHNOLOGY (VFD - voltage & frequency dependent) Passive standby topology (off-line) is the most frequently used UPS topology for protecting against blackout. In normal mode, the UPS supplies power to the application directly from the mains, filtered but without active conversion. The battery is charged from the mains. In the event of a power cut or fluctuation, the UPS delivers stable power from the battery. The advantages of this topology are low cost and adequacy for office environments. Passive standby topology is not suitable if the power supply is of lower quality (industrial sites). LINE-INTERACTIVE TECHNOLOGY (VI - voltage independent) Line interactive topology is mostly used for enterprise networks and IT applications. It protects from blackout, undervoltage and overvoltage. In normal mode, the device is controlled by a microprocessor that monitors the quality of the supply and reacts to fluctuations. A voltage stabilizer (AVR) is enabled to boost or reduce the supply voltage to compensate for the fluctuations. The main advantage of this topology is that it enables compensation of under and overvoltage without using the batteries. Mains input Mains input filter OFF-LINE UPS LINE- INTERACTIVE UPS Battery charger AVR filter Stabilizer Switch Battery charger Switch Inverter Inverter UPS output UPS output OFF-LINE TECHNOLOGY Due to the lower protection level, this type is not recommended/produced by VISION UPS LINE-INTERACTIVE TECHNOLOGY Square wave output Budget (p.10-13) Pro Blue (p.14) Pro Blue rackmount (p.14) ON-LINE TECHNOLOGY Single-phase UPS (1/1) Pure sine wave output Jupiter Pro (p.16) Jupiter XL (p.18) Marathon (p.36) Spirit / Vision LCD (p.20/24) Spirit XL / Vision XL (p.22/26) Marathon (p.36-39) ON-LINE TECHNOLOGY (VFI - voltage and frequency independent) Double conversion topology (on-line) is a basis for UPS designed for continuous power protection from all eight power problems: power failure, undervoltage, overvoltage, frequency variation, voltage harmonics, voltage distortion, high-frequency transient, power surge (with galvanic isolation). It ensures a consistent quality of power supply regardless of disturbances in the incoming mains. The output voltage is entirely regenerated by a sequence of AC to DC conversion followed by DC to AC conversion in order to create power supply without any electrical interference. Double conversion UPSs can be used with any type of equipment as there is no switching when changing over to battery power. Mains input System filter Manual Static Rectifier Inverter UPS output ON-LINE UPS Single-phase UPS (3/1) Vision II (p.30) Vision XL II (p.28) Three-phase UPS (3/3) Premium DSP (p.32) Marathon three-phase (p.42) Vision Modular UPS (p.44-47) INCLUDING GALVANIC ISOLATION TRANSFORMER Operation in normal mode Operation in battery mode Operation in static Operation in manual Marathon + (p.40), Vision II + (p.30) Premium DSP + / ++ (p.32), Premium 33 + (p.34) 4 5
4 Fields of application Home PC BUDGET PRO BLUE Marathon 3/3 Small offices PRO BLUE JUPITER PRO JUPITER XL SPIRIT Workstation VA VA 20kVA SOHO VA VA pure sine wave VA pure sine wave 1-3kVA Healthcare SPIRIT XL VISION XL (II) Marathon XL VISION LCD Marathon Marathon + VISION II (+) Three-phase UPS PREMIUM DSP Security systems Broadcast 1-3kVA 1-10kVA 1-3kVA 1-3kVA 1-3kVA 1-10kVA 6-20kVA (N+1) - "+" kVA Datacentres IT SPIRIT XL VISION XL (II) Marathon XL VISION II (+) Three-phase UPS PREMIUM DSP PREMIUM 33 + VISION MOD Modular UPS VISION MOD Servers Telecom VoIP 1-3kVA 1-10kVA 1-3kVA 6-20kVA (N+1) - "+" kVA kVA Modules 6-10kVA Modules 20kVA Industry Three-phase UPS Modular UPS Airports Marathon + VISION II (+) PREMIUM DSP PREMIUM 33 + VISION MOD VISION MOD Oil&Gas Government Education 1-10kVA 6-20kVA (N+1) - "+" kVA kVA Modules 6-10kVA Modules 20kVA 6 7
5 Uninterruptible Power supply U P S U P S VISION - More than UPS... BUDGET PRO BLUE JUPITER PRO JUPITER XL 1/1 3/3 VISION APF Line-interactive Active Power Filter 1-10kVA kVA A VA VA VA pure sine wave VA pure sine wave Rectifiers Thyristor Rectifiers IGBT VIS-Rectifiers Telecom Chargers SPIRIT (XL) VISION LCD VISION XL (II) VISION II (+) Rectifiers industrial/telecom On-line (1/1) VDC VDC 48VDC 12/24/48VDC 1-3kVA 1-3kVA 1-10kVA 1-10kVA ST-Inverters INV-Series SA-Series SB-Inverters On-line (3/1-3/3) MARATHON Long Backup Series with big charger and external batteries VISION II (+) 10-20kVA PREMIUM DSP PREMIUM kVA (+/++) kVA Marathon Marathon XL Marathon + Marathon 3/3 1-3kVA 1-3kVA 1-10kVA 20kVA Inverters industrial/telecom Battery Analyzer Lightning protection 12VDC 1-4kW parallel VRLA 12V/7-200Ah Lightning protection 48VDC Battery Analyzer New Development! Lightning protection 24/48/110/220VDC Spike protection 48VDC Modular UPS (1/1-3/1-3/3 ) VISION MOD Modules 6-10kVA 1/1 3/1 VISION MOD Modules 20kVA 3/3 XL - tower and rackmount version "2 in 1" + - with galvanic isolation transformer II - allows parallel connection (up to 4 units) Solar Technology All Applications Solar Oil/Gas Solar Home Use Solar Solar Charger / Controller Inverter Panels Hybrid Solar UPS 8 9
6 Optional: IEC to Schuko converter BUDGET PRO VA LED Panel VА LCD Display VA USB USB RJ45/11 Line-interactive technology (VI) IEC-outlets IEC outlets Automatic Regulator (AVR, "Boost and trim") Transfer to battery at under and over voltage Self-diagnostic function Battery cold start Genset-compatible Auto-charging in Off-Mode Auto-restart function Automatic computer shutdown Audible and visible alarm Surge protection RJ45/11 protection (EMI/RFI filtering) USB interface including software Options:, IEC to Schuko converter 2 years warranty (electronics) Nominal capacity, VА Power, W voltage range stabilizer (AVR) frequency range AC voltage (battery mode) AC frequency (battery mode) Transfer time Waveform Battery (voltage and amount) Backup time Typical recharge time Outlets IEC (Schuko on request) Protection Visual indication Acoustic indication Humidity / Noise level Dimensions WxDxH Weight Warranty Software V (1x 4,5Ah) 12V (1x 7Ah) 220/230/240V / 110/120V V / V Boost and trim 50/60Hz (auto sensing) +- 0% 50/60Hz +-1Hz typical: 2-6ms / maximum: 10ms Square wave (simulated sine wave) 12V (1x 9Ah) 24V (2x 7Ah) 5-10 minutes 6-8 hours recover to 90% capacity 4 outlets ( VA) / 6 outlets ( VA) USB-port RJ45/11 (telephone/modem) overload - short circuit - discharge - overcharge 24V (2x 9Ah) LED: AC-Mode / Battery-Mode / Alarm (optional: LCD-display) Battery mode - low battery - overload - battery replacement alarm - fault 0-40 (non condensing) / less than 40dB 101x302x142mm 149x338x160mm 158x380x196mm 3,6kg 4,3kg 4,9kg 7,8kg 8kg 11,1kg 11,5kg 2 years (electronics) for Windows, Mac, Linux 10 11
7 RJ11 Optional: IEC to Schuko converter BUDGET 650 / 1200 / 1500VA RJ11 DB9- DB9- IEC-outputs Line-interactive technology (VI) Transfer to battery at under and over voltage Automatic Regulator (AVR, "Boost and trim") RJ11 protection (EMI/RFI filtering) Battery (DC) cold start Automatic computer shutdown Audible and visible alarm Surge protection DB9 interface including software Option: IEC to Schuko converter 2 years warranty (electronics) Nominal capacity, VА Power, W voltage range stabilizer (AVR) frequency range waveform voltage (Line mode) voltage (Battery mode) frequency (Battery mode) Battery (capacity х amount) Backup time (typical computer load) IEC outlets (amount) Dimensions WxHxD (Weight kg) RJ11 protection (telephone) Overload protection Short circuit protection Warranty Software (RUPS) VAC Boost & Trim 50Hz Square wave (simulated sine wave) 220/230VAC (± 10%) 220/230VAC (± 5%) 50Hz (± 1%) 7Ah x 1 7Ah x 2 9Ah x 2 10min 3 4 DB9 96x163x320mm (5,2kg) 127x223x390mm (10,0kg) 2 years (electronics) for Windows, Mac, Linux 127x223x390mm (12,8kg) 12 13
8 PRO BLUE VA RJ11 USB RJ11 USB Outlets IEC Line-interactive technology (VI) Optional: IEC to Schuko converter Transfer to battery at under and over voltage UPS with intelligent LCD Display Automatic computer shutdown Automatic Regulator (AVR, "Boost and Trim") Very wide input and voltage range Up to 65 min runtime Battery (DC) cold start Nominal capacity, VА Power, W voltage range stabilizer (AVR) frequency range waveform voltage (Line Mode) voltage (Battery mode) frequency (Battery mode) Battery (capacity x amount) Backup time (typical computer load) IEC outlets (amount) VAC Boost & Trim 50Hz Square wave (simulated sine wave) 220/230VAC (± 10%) 220/230VAC (± 5%) 50Hz (± 1%) 7Ah x 1 9Ah x 1 7Ah x 2 9Ah x 2 9Ah x min 10-65min 3 4 Overload and short circuit protection RJ11 telephone line protection Audible and visible alarm USB interface including software RJ11/RJ45 protection Tower: Dimensions HxWxD (Weight kg) Rack 19": Dimensions HxWxD (Weight kg) Protection from overload and short circuit 159x95 x325mm (5,2kg) - 159x95 x325mm (6,0kg) 2Ux483 x310mm (8,7kg) USB 222x124 x325mm (10,6kg) 2Ux483 x310mm (12,5kg) 222x124 x325mm (11,1kg) 2Ux483 x310mm (13,2kg) 222x124 x385mm (13,1kg) 3Ux483 x310mm (15,8kg) Noise suppression 2 years warranty (electronics) Warranty Software (UPSilon 2000) 2 years (electronics) for Windows, Mac, Linux 14 15
9 RJ11 JUPITER PRO VA Line-interactive technology (VI) with pure sine wave Jupiter Pro RM rackmount version 1/2/3kVA - optional 12A charger (on request) Optional: IEC to Schuko converter USB On/Off RJ11 USB s On/Off s Automatic Regulator (AVR, "Boost and Trim") Battery transfer at under and over voltage Including software for automatic computer shutdown Internal static and manual bypass Pure sinewave output Intelligent LCD display Battery (DC) cold start Audible and visible alarm Overload and short circuit protection RJ11 protection, surge protection USB interface Option: SNMP-card 2 years warranty (electronics) Nominal capacity, VA Power, W voltage range stabilizer (AVR) frequency range voltage (Line mode) voltage (Battery mode) frequency (Battery mode) Battery (capacity x amount) Backup time IEC outlets (amount) RJ11 protection Dimensions WxDxH - Weight Overload protection Short circuit protection Noise suppression Warranty Software (UPSilon 2000) VAC (option: VAC) Boost & Trim 50/60Hz VAC 220/230VAC (± 5%) - pure sine wave 50/60Hz (± 1%) 7Ah x 2 8Ah x 2 8Ah x 3 8Ah x 4 over 10-35min ( for IT-load) 3/4 USB (standard) SNMP (Option) Standard 145x360x215mm 11,5kg 145x360x215mm 13,2kg 145x430x215mm 17,9kg 2 years (electronics) for Windows, Mac, Linux 200x475x337mm 26,3kg 16 17
10 Slot for SNMP/Relay card Power s IEC JUPITER XL VA RS232 Fuses USB Line-interactive technology (VI) with pure sine wave EPO RJ11/45 Additional backup (Battery input) Automatic Regulator (AVR, "Boost and Trim") Transfer to battery at under and over voltage Hot swappable battery replacement Optional additional backup time User-friendly LCD display Pure sinewave output 4A charger Battery (DC) cold start Large backup time voltage range from V Rack & Tower - 2 in 1 design RJ11/45 phone / network protection Overload and short circuit protection EPO (Emergency Power Off) True RS232/USB interface including software Options: SNMP - Relay - AS400 card Audible and visible alarm 2 years warranty (electronics) Nominal capacity, VA Power, W voltage range stabilizer (AVR) frequency range voltage (Line mode) voltage (Battery mode) frequency (Battery mode) Battery (capacity x amount) Backup time IEC outlets (amount) RJ11/RJ45 protection Dimensions HxWxD (Weight kg) Overload protection Short circuit protection Noise suppression Warranty Software (UPSilon2000) VAC Boost & Trim 50/60Hz 220/230VAC (± 9%) 220/230/240VAC (± 3%) - pure sine wave 50/60Hz (± 0,1%) 7Ah x 4 9Ah x 4 7Ah x 8 9Ah x 8 > 10 minutes at 100% load 6 (optional: 19" module with 4 IEC and 2 Schuko outlets) 88x440x485mm (23,7kg) 88x440x690mm (26,2kg) RS232 - USB - EPO 88x440x690mm (42kg) 2 years (electronics) for Windows, Mac, Linux 88x440x690mm (46kg) 18 19
11 SPIRIT VА RS232 RJ11/45 Free Slot (SNMP,...) Additional Battery RS232 USB Slot for SNMP/Relay card Additional Battery input USB On-line Double conversion technology (VFI) Outlets RJ11/45 Power Outlets Power Optional: IEC to Schuko converter DSP (Digital Signal Processor) technology Internal static and manual bypass Power Factor up to 0.99 Wide input voltage range Rack / Tower (XL design) Battery (DC) cold start Site wiring fault indication Self testing when UPS startup RJ45/11 network protection Intelligent management through RS232 & USB For extended backup time check MARATHON series (external batteries) Options: SNMP adapter Relay card (dry contacts) External maintenance 2 years warranty (electronics) Model Power Minimum voltage Maximum voltage power factor voltage range Waveform stabilization Crest factor Efficiency Battery Backup time Power of the internal charger Protection RJ11/45 protection / protection against Overload in battery mode Overload in utility mode Alarms - Information Audible alarm LED-Alarm Environment Temperature / Altitude / Humidity Audible noise at 1m Standard Optional Dimensions Weight WxDxH Standard 1000VA 2000VA 3000VA 800W 1600W 2400W 115VАС (at 50% load) 295VАС 45Hz~55Hz±0.5Hz or 55Hz~65Hz±0.5Hz (Auto sensing) VAC 7% at 100% non-linear load 200 / 208 / 220 / 230 / 240VAC Pure sine wave < 3% at 100% linear load 50/60Hz +-0,2% ± 2% 3 : 1 86% (Utility Mode) / 94% (Battery Mode) VRLA 24VDC (2x9Ah) 48VDC (4x9Ah) 72VDC (6x9Ah) 5-8min with internal batteries / variable with external batteries 1A 1A 1A Overload - Temperature - Short circuit 108%±5%<Load 150%±5% exceed 30s, cut off and alarm 150%±5%<Load<200%±5% exceed 300ms, cut off and alarm 108%±5%<Load 150%±5% exceed 30s transfer to bypass and alarm 150%±5%<Load<200%±5% exceed 300ms transfer to bypass and alarm Beeping sound for battery backup, battery low, overload status, fault status Mains, inverter, bypass, fault, battery level & output voltage, load, battery voltage, error codes Internal static (automatic) and manual bypass / External bypass optional 0-40 C / less than 1500m / 0-95% non-condensing < 50dBA RS232 / USB SNMP card / Dry contact (relay) card 10,5kg 22kg 27kg 144x361x215mm 191x428x337mm CE-Certificate 20 21
12 SPIRIT XL 1-3kVA (1/1) 1) USB 2) RS232 3) Slot for SNMP/Relay 4) Additional battery input 5) Power 6) Standard outlets (IEC) 7) fuse 8) RJ45/11 Surge protection VA/ 3000VA 1000VA On-line Double conversion technology (VFI) DSP (Digital Signal Processor) technology Internal static and manual bypass Power Factor up to 0.99 Wide input voltage range Rack / Tower (XL design) Battery (DC) cold start Site wiring fault indication Self testing when UPS startup RJ45/11 network protection Intelligent management through RS232 & USB For extended backup time check MARATHON XL series (external batteries) Options: SNMP adapter Relay card (dry contacts) External maintenance 2 years warranty (electronics) Model Power Minimum voltage Maximum voltage power factor voltage range Waveform stabilization Crest factor Efficiency Battery Backup time Power of the internal charger (UPS with internal batteries) Power of the internal charger (UPS without internal batteries) Additional backup time Protection RJ11/45 protection / protection against Overload in battery mode Overload in utility mode Alarms - Information Audible alarm LED-Alarm Standards Industry Environment Temperature / Altitude / Humidity Audible noise at 1m (1M) Standard Optional Dimensions Weight WxDxH 1000VA 2000VA 3000VA 800W 1600W 2400W 115VАС (at 50% load) 295VАС 45Hz~55Hz±0.5Hz or 55Hz~65Hz±0.5Hz (Auto sensing) up to VAC 7% at 100% non-linear load 200 / 208 / 220 / 230 / 240VAC Pure sine wave < 3% at 100% linear load 50/60Hz +-0,02Hz ± 2% 3 : 1 86% (Utility Mode) / 94% (Battery Mode) VRLA 24VDC (2x9Ah) 48VDC (4x9Ah) 72VDC (6x9Ah) 3-5 min at full load 3-5 min at full load 3-5 min at full load 1A 1A 1A 6A or 12A 6A or 12A 6A or 12A (additional 19" battery modules) and see MARATHON series Overload - Temperature - Short circuit 108%±5%<Load 150%±5% exceed 30s, cut off and alarm 150%±5%<Load<200%±5% exceed 300ms, cut off and alarm 108%±5%<Load 150%±5% exceed 30s transfer to bypass and alarm 150%±5%<Load<200%±5% exceed 300ms transfer to bypass and alarm Beeping sound for battery backup, battery low, overload status, fault status Mains, inverter, bypass, fault, battery level & output voltage, load, battery voltage, error codes Internal static (automatic) and manual bypass / External bypass optional CE-Certificate 0-40 C / less than 1500m / 0-95% non-condensing < 50dBA RS232 / USB SNMP card / Dry contact (relay) card 12kg 22kg 26kg 440x380x88mm (2U) 440x520x132mm (3U) 22 23
13 RS232 Slot for SNMP/Relay card VISION LCD 1-3kVA (1/1) Additional Battery input RJ11/45 Outlets fuse On-line Double conversion technology (VFI) Power input Internal static and manual bypass Power Factor up to 0.99 Wide input voltage range Battery (DC) cold start RJ11 network protection Self testing when UPS startup Intelligent management through RS232 & USB with less than 3% THD EMI/RFI noise filter Up to 15 minutes backup time at full load with internal batteries For extended backup time check MARATHON series (external batteries) Options: SNMP/AS400 card USB Relay card (dry contacts) External maintenance 2 years warranty (electronics) Model Power Minimum voltage Maximum voltage power factor voltage range Waveform stabilization Crest factor Efficiency Battery Backup time Power of the internal charger Protection RJ11/45 protection / protection against Overload in battery mode Alarms - Information Audible alarm LED-Alarm Environment Temperature / Altitude / Humidity Audible noise at 1m Standard Optional Dimensions Weight (with/without batteries version) WxDxH Standard 1000VA 2000VA 3000VA 700W 1400W 2100W 165VАС (120VAC at 50% load) 276VАС (300VAC at 50% load) 45~55Hz up to VAC 7% at 100% non-linear load 220 / 230 / 240VAC Pure sine wave < 3% at 100% linear load 50/60Hz +-0,2% ± 2% 3 : 1 up to 85% VRLA 36VDC (3x7Ah) 96VDC (8x7Ah) 96VDC (8x7Ah) 8-15min at full load 1A Overload - Temperature - Short circuit % 1 minute, then switch to bypass more than 150%: switch to bypass after 200ms Beeping sound for battery backup, battery low, overload status, fault status Mains, inverter, bypass, fault, battery level & output voltage, load, battery voltage, error codes Internal static (automatic) and manual bypass / External bypass optional 0-40 C / less than 1500m / 10-90% < 55dBA RS232 SNMP card / Dry contact (relay) card / USB 12,1kg 27,2kg 28,2kg 140x405x210mm 195x470x330mm CE-Certificate 24 25
14 VISION XL 1-3kVA (1/1) On-line Double conversion technology (VFI) 1) USB 2) RS232 3) EPO (Emergency Power Off) 4) Slot for SNMP/Relay/ AS400 5) Additional battery input 6) Power 7) Standard outlets (IEC) 8) Programmable outlets (IEC) 9) Cabinet grounding 10) Cooling fans 11) fuses kVA 2kVA 3kVA DSP (Digital Signal Processor) technology Internal static and manual bypass Power Factor up to 0.99 Wide input voltage range Rack / Tower (XL design) Battery (DC) cold start Site wiring fault indication RJ45/11 network protection Self testing when UPS startup Intelligent management through RS232 & USB For extended backup time check MARATHON XL series (external batteries) EPO Contact (Emergency Power Off) converter 50/60/50Hz Powerful built-in charger up to 2,7A Additional battery modules Programmable outlets Hot-swappable batteries Options: SNMP/AS400 card Relay card (dry contacts) External maintenance 2 years warranty (electronics) Model Power Minimum voltage Minimum voltage at full load Maximum power factor Waveform stabilization Crest factor Efficiency Battery Backup time Power of the internal charger Additional backup time Protection / protection against Overload protection Alarms - Information Audible alarm LED-Alarm Standards EMV Environment Temperature Humidity Audible noise at 1m (1M) RS232 SNMP / Relay / AS400 USB Dimensions Weight WxHxD 1000VA 2000VA 3000VA 800W 1600W 2400W 120VАС 160VАС 288VАС 45 65Hz > % 208 / 220 / 230 / 240VAC Pure sine wave < 2% 50/60Hz ± 1% 3 : 1 85% VRLA 36VDC 72VDC 72VDC > 8min > 8min > 8min 1,1A 2,1A 2,7A (additional 19" battery modules) and see MARATHON series Overload - Temperature - Short circuit > 30sec at 150% - switching to bypass-mode Beeping sound for battery backup, battery low, overload status, fault status Mains, inverter, bypass, fault, battery level & output voltage, load, battery voltage, error codes Internal static (automatic) and manual bypass / External bypass optional EN , EN C 0-95% non-condensing < 50dBA Option (free slot) 14,5kg 27,1kg 29,8kg 440x88(2U)x405mm 440x88(2U)x650mm 440(2U)x88x650mm 26 27
15 VISION XL II 6kVA (1/1) 10kVA (1/1, 3/1) Free slot for SNMP, Relay card and AS 400 EPO (Emergency Power Off) RS 232 N+1 Parallel Cooling fans On/off switch Additional battery input On-line Double conversion technology (VFI) 6kVA (with internal batteries) 10kVA (no internal batteries) power factor up to 0.99 DSP (Digital Signal Processor) technology Parallel Redundancy On Line UPS (Up to 4 units) Programmable frequency through front panel LED-LCD front panel (easily controlling) Wide input voltage range (160V-280V) ECO-Mode for energy-saving Internal static and manual bypass EPO (Emergency Power Off) contact Extended runtime (Plug & Play) Rack/Tower (XL-design) Galvanic isolation (optional) Battery (DC) cold start RS232 interface Inductive load acceptable Options: SNMP/AS400 Card Relay card (dry contacts) External battery charger External maintenance bypass 2 years warranty (electronics) Nominal capacity Power voltage range (1/1 and 3/1) power factor and Waveform Stabilization Crest factor Efficiency Battery and voltage VDC Power of the internal charger Backup time (at full/half load) Additional batteries for long backup time Protection / Overload, inverter protection Overload, bypass protection Alarms - Information Audible alarm Visual alarm Standards EMV Protection class RS232 / Relay card AS400 / SNMP / EPO Dimensions Vision II 6kVA Module Weight WxHxD Dimensions Vision II 10kVA Module Weight WxHxD 6kVA (1/1) 10kVA (1/1-3/1) 5,4kW (1/1) 9kW (1/1-3/1) VАС / VАС 45-65Hz > 0.97 (at linear load) < 5% at 100% linear load 208 / 220 / 230 / 240VAC - Pure sine wave < 2% 50/60Hz ±2% 3:1 Up to 91% VRLA - 240VDC (20 batteries) 2A (optional: additional chargers) 5-15min (Option) Overload, Overheating, Short Circuit, Battery Low, Noise and Spike Suppression % for 160 Seconds % for 500 Seconds Beeping sound for Line Failure, Battery Low, - Overload Status, Fault Status Line - Backup - Eco Mode,, Battery Low/Bad/Disconnect, Overload, Fault /, Load %, Battery, Inner Temperature Internal static (automatic) and manual bypass / External bypass optional EN , EN , UL1778, EN , EN , FCC Class A IP20 / Option Option / Option / Vision II XL 6kVA UPS with int. batteries Battery module Galvanic isolation 58,0kg 58,0kg 42,0kg 440х176x660mm (4U) 440x133x660mm (3U) 440x88x660mm (2U) Vision II XL 10kVA UPS without batteries Battery module Galvanic isolation 30,0kg 67,0kg 42,0kg 440x133x660mm (3U) 440х133x660mm (3U) 440x88х660mm (2U) 28 29
16 VISION II (+) 6-20kVA (1/1-3/1) Free slot for SNMP, Relay,... ЕРО (Emergency Power Off) Fuse N+1 Parallel RS 232 Cooling fan Additional battery input On-line Double conversion technology (VFI) power factor up to 0.99 DSP (Digital Signal Processor) technology Parallel Redundancy On-line UPS (up to 4 Units) Programmable frequency through front panel Internal static and manual bypass LED-LCD front panel (easily controlling) Wide input voltage range (160V - 280V) Extended runtime (Plug & Play) Galvanic isolation (Vision II +) Eco-mode for energy-saving Battery (DC) cold start Inductive load acceptable Self testing when UPS start up RS232- EPO (Emergency Power Off) Options: SNMP/AS400 card Relay card (dry contacts) External battery charger External maintenance 2 years warranty (electronics) Model Power Minimum voltage Maximum voltage power factor at 100% linear load at 100% linear load Waveform voltage range Crest factor Efficiency Battery and voltage (VDC) Backup time (at full/half load) Additional batteries for long backup time Protection Galvanic isolation transformer / Overload protection Alarms and information Audible alarms LEDs + Standarts EM-conformity Protection class Environment Temperature Humidity Noise (1M) RS232 / EPO Relay card / AS400 / USB / RS485 / SNMP Dimensions Weight (with galvanic isolation) Dimensions: WxHxD (with galvanic isolation) Weight (without galvanic isolation) Dimensions: WxHxD (without galvanic isolation) 6kVA 10kVA 10kVA 15kVA 20kVA 5,4kW 9kW 13,5kW 18kW 160VAC 280VAC 277VAC 485VAC 45Hz - 65Hz > 99% > 95% < 5% < 30% 208/220/230/240VAC 200/220/230/240VAC (208/120 - Option) Pure sine wave 2% 50/60Hz ± 0,2% ± 2 % 3 : 1 Up to 91% (ECO mode up to 98%) > 90% (without transformer) VRLA - 240VDC (20 batteries) 10-25min (additional batteries optional) Only external batteries (= Vision II+) Overload, Overheating, Short Circuit, Battery Low, Noise and Spike Suppression Inverter: % - 160sec / : % - 500sec Sound for Line Failure, Battery Low, - Overload Status, Fault Status Line, Backup, Eco Mode,, Battery Low/Bad/Disconnect, Overload, Fault /, Load %, Battery, Temperature, Error code Internal static (automatic) and manual bypass / External bypass optional EN , EN , UL1778, EN , EN , FCC Class A IP C 0-95% < 50dB Option 122kg 143kg 130kg 290x748x645mm 290x881x645mm 290х1014х645mm 87kg 100kg 60kg (no batteries) 290x748x645mm 290x748x645mm 290х748х645mm 30 31
17 LED indication (, battery, inverter, bypass...) PREMIUM DSP kVA (3/3) PREMIUM DSP + with galvanic isolation for phase On-line Double conversion technology (VFI) (, frequency, temperature...) PREMIUM DSP ++ PREMIUM DSP ++ with galvanic isolation for phase, neutral and bypass Parallel redundancy On-line UPS (up to 4 units) DSP (Digital Signal Processor) technology Charger-boost if load is less than 100% IGBT technology (rectifier&inverter) Internal static and manual bypass Power Factor up to 0,99 ECO-Mode for energy-saving Self testing when UPS start up Optional battery runtime Inductive load acceptable Wide input voltage range LCD-LED Display Audible and visible alarms Intelligent management via RS232 EPO (Emergency Power Off) Relay card (dry contacts) Options: SNMP/AS400 card, Remote LCD panel External maintenance 1 year warranty (electronics) Model (kva) Power (kw) Minimum voltage Maximum voltage Power Factor Waveform voltage range Crest factor Efficiency Battery and voltage Backup time Protection / Overload protection at load % / % Alarms - Information Audible alarm LED-Alarm Standards EMV Protection class Environment Temperature / Humidity Noise RS232 / Relay card AS400 / SNMP / EPO Dimensions Premium DSP Weight (without batteries - kg) Width mm Depth mm Height mm Dimensions Premium DSP + (Premium DSP ++ on request) Weight (without batteries - kg) Width mm Depth mm Height mm % load: -15% / 90% load: -45% / 60% load: -60% 500VАС 50/60Hz (45-65Hz) 0.99 < 4% 380/400/415V (230V and 480V on request) Sine Wave < 3% linear load (Premium DSP+/++ < 1,5%) - < 5% non Linear Load (Premium DSP+/++ < 2,5%) 50/60Hz (±1%) ± 1% 3:1 95% (at 100% linear load) Internal static (automatic) and manual bypass / External bypass optional VRLA - 2х372VDC (2х31batteries) 2х360VDC (2х30 batteries) 10min - 2 hours (internal batteries andexternal battery cabinets) Overload, Overheating, Short Circuit, Battery Low, Noise and Spike Suppression 10min / 1min Beeping sound for Line Failure, Battery Low, - Overload Status, Fault Status Line - Backup - Eco Mode,, Battery Low/Bad/Disconnect, Overload, Fault /, Load %, Battery /Runtime, Inner Temperature EN , EN , IEC (class VFI) IP C / 0-95% < 55dB Option/Option/
18 PREMIUM kVA (3/3) LED indication (, battery, inverter, bypass...) (, frequency, temperature...) On-line Double conversion technology (VFI) Galvanic isolation transformer LCD-LED Display IGBT technology (inverter) Optional battery runtime Inductive load acceptable Wide input voltage range Parallel redundancy (optional) Internal static and manual bypass Self testing when UPS start up Audible and visible alarm Model (kva) Power (kw) Minimum voltage Maximum voltage Power Factor Waveform voltage range Crest factor Efficiency Battery Backup time Additional batteries for long backup time Protection VAC 470VАС 50/60Hz (45-65Hz) > 0.85 < 5% at 100% linear load 380/400/415V (230V and 480V on request) Pure sine wave < 3% (linear load) - < 5% (non-linear load) 50/60Hz (± 1%) ± 1% 3:1 up to 90% (97% ECO Мode - Option) VRLA 360VDC 10min - 2 hours - in external battery cabinet / Overload, Overheating, Short Circuit, Battery Low, Noise and Spike Suppression Intelligent management via RS232 EPO (Emergency Power Off) Relay card (dry contacts) Options: SNMP/AS400 card External maintenance 1 year warranty (electronics) Overload protection at load % Overload protection at load % Alarms - Information Audible alarm LED-Alarm Standards EMV Protection class Environment Temperature Humidity Noise RS232 Relay card AS400 / SNMP / EPO Dimensions Weight (without batteries - kg WxDxH (without batteries) - mm 10min 1min Beeping sound for Line Failure, Battery Low, - Overload Status, Fault Status Line - Backup - Eco Mode,, Battery Low/Bad/Disconnect, Overload, Fault /, Load %, Battery /Runtime, Inner Temperature Internal static (automatic) and manual bypass / External bypass optional EN , EN , IEC (class VFI) IP C 0-95% < 55dB Option / Option / x680x x800x x800x
19 MARATHON VА RS232 RJ11/45 Free Slot (SNMP,...) Additional Battery RS232 USB Slot for SNMP/Relay card Additional Battery input USB Extremely long backup-time with external batteries and big charger! /3500VA VA MARATHON /3500VA Line-interactive technology (VI) with pure sine wave output Only with external batteries - big charger (10/20A adjustable) Wide input voltage range ( V) Fully digitalized microprocessor controlled Energy saving function with UPS Green Mode Battery (DC) cold start Wide application range (Rectifier/Inverter/UPS) MARATHON VA On-line Double conversion technology (VFI) Only with external batteries - big charger (6/12A) DSP (Digital Signal Processor) technology ECO-Mode for energy-saving Internal static and manual bypass Intelligent management through USB-interface Site wiring fault indication Wide input voltage range Battery (DC) cold start Self testing when UPS startup Вypass voltage range can be set Optional battery runtime RJ45/11 network protection SNMP card (Option) Dry contacts/relay (Option) PFC up to years warranty (electronics) Model Power Technology Minimum voltage Maximum voltage power factor voltage range Waveform stabilization Crest factor Efficiency Battery Power of the internal charger (UPS without internal batteries) Protection RJ11/45 protection / protection against Overload in battery mode Overload in utility mode Alarms - Information Audible alarm LED-Alarm Standards Industry Environment Temperature / Altitude / Humidity Audible noise at 1m Standard Optional Dimensions Weight (without batteries) WxDxH Outlets RJ11/45 Power 800VA 1000VA 1500VA 3500VA 640W 800W 1200W 2800W line-interactive UPS 145VAC 285VAC 38-70Hz /230VAC Pure sine wave 50Hz+-1Hz 220VDC+-10% 2,5 : 1 92% 130VAC 290VAC VRLA 12VDC 24VDC 48VDC 10/20А - Overload - Temperature - Short circuit CE-Certificate 0-40 C / less than 1500m / 0-95% < 50dB ,4kg 15kg 18,6kg 27kg 272х285 х165mm 313х295х189mm Marathon on-line 350х230 х480mm Outlets Power Optional: IEC to Schuko converter 1000VA 2000VA 3000VA 800W 1600W 2400W on-line UPS 115VАС (at 50% load) 295VАС 45Hz~65Hz±0.5Hz (аauto sensing) VAC 200 / 208 / 220 / 230 / 240VAC Pure sine wave 50/60Hz +-0,2% ± 2% 3 : 1 86% (Utility Mode) / 94% (Battery Mode) VRLA 24VDC 48VDC 72VDC 6A or 12A 6A or 12A 6A or 12A Overload - Temperature - Short circuit 108%±5%<Load 150%±5% exceed 30s 108%±5%<Load 150%±5% exceed 30s Battery backup, battery low, overload status, fault battery backup, battery low, overload status, fault Internal static (automatic) and manual bypass CE-Certificate 0-40 C / less than 1500m / 0-95% < 50dB RS232 / USB SNMP / Relay card (dry contacts) 5,5kg 10kg 10kg 144x361x215mm 191x428x337mm 191x428x337mm 36 37
20 MARATHON XL VA 1) USB 2) RS232 3) Slot for SNMP/Relay 4) Additional battery input 5) Power 6) Standard outlets (IEC) 7) fuse 8) RJ45/11 Surge protection VA/ 3000VA 1000VA Extremely long backup-time with external batteries and big charger! On-line Double conversion technology (VFI) DSP (Digital Signal Processor) technology Power Factor up to A or 12A charger available ECO-Mode for energy-saving Internal static and manual bypass Wide input voltage range Battery (DC) cold start Rack / Tower (XL design) Self testing when UPS startup Вypass voltage range can be set Optional battery runtime RJ45/11 network protection Site wiring fault indication Intelligent management through RS232 & USB Options: SNMP card Relay card (dry contacts) External maintenance 2 years warranty (electronics) Model Power Minimum voltage Maximum voltage power factor voltage range Waveform stabilization Crest factor Efficiency Battery Backup time Power of the internal charger Additional backup time Protection RJ11/45 protection / protection against Overload in battery mode Overload in utility mode Alarms - Information Audible alarm LED-Alarm Standards Industry Environment Temperature / Altitude / Humidity Audible noise at 1m (1M) Standard Optional Dimensions Weight (with/without batteries version) WxDxH 1000VA 2000VA 3000VA 800W 1600W 2400W 115VАС (at 50% load) 295VАС 45Hz~55Hz±0.5Hz or 55Hz~65Hz±0.5Hz (Auto sensing) up to VAC 7% at 100% non-linear load 200 / 208 / 220 / 230 / 240VAC Pure sine wave < 3% at 100% linear load 50/60Hz +-0,02Hz ± 2% 3 : 1 86% (Utility Mode) / 94% (Battery Mode) VRLA 24VDC 48VDC 72VDC According to the amount of batteries 6A or 12A 6A or 12A 6A or 12A (additional 19" battery modules) Overload - Temperature - Short circuit 108%±5%<Load 150%±5% exceed 30s, cut off and alarm 150%±5%<Load<200%±5% exceed 300ms, cut off and alarm 108%±5%<Load 150%±5% exceed 30s transfer to bypass and alarm 150%±5%<Load<200%±5% exceed 300ms transfer to bypass and alarm Beeping sound for battery backup, battery low, overload status, fault status Mains, inverter, bypass, fault, battery level & output voltage, load, battery voltage, error codes Internal static (automatic) and manual bypass / External bypass optional CE-Certificate 0-40 C / less than 1500m / 0-95% non-condensing < 50dBA RS232 / USB SNMP card / Dry contact (relay) card 12kg / 7kg 22kg / 12kg 26kg / 12kg 440x380x88mm (2U) 440x520x132mm (3U) 38 39
21 MARATHON + Extremely long backup-time! 1-10kVA (1/1) VA RS232 Fuse Free Slot Battery input RJ11/45 Outlets Power DC-switch for cold start RS232 EPO Free slot Battery fuses 10000VA fuses switch Connections On-line Double conversion technology (VFI) 10000VA VA Galvanic isolation transformer Power Factor up to 0.98 Wide voltage range VAC Internal static and manual bypass with less than 3% THD EMI/RFI noise filter Battery (DC) cold start Additional batteries for long backup time RJ45/11 protection for telephone and modem line Short circuit and overload protection Intelligent management via RS232 Slot for relay card and AS 400 Extra for 10kva/8kW Big charger (12А) Diesel-Genset Compatibility Suitable for inductive load Options: SNMP card for monitoring EPO (Emergency Power Off) 2 years warranty (electronics) Nominal capacity Power Minimum voltage Maximum voltage power factor Waveform voltage range Crest factor Efficiency Battery (VDC) Backup time (at full/half load) Additional batteries for long backup time Protection Galvanic isolation transformer / Overload capability Alarms and information Audible alarm LEDs + Standards EM-conformity Protection class Environment Temperature Humidity Noise (1М) RS232 Relay card / AS400 USB / RS 485 / SNMP Dimensions Weight Dimensions WxDxH (without batteries) - mm Software Warranty 1000VA 2000VA 3000VA 10000VA 700W 1400W 2100W 8000W 165V (at 100% load) / 120V (at 50% load) 160VAC 276V (at 100% load) / 300V (at 50% load) 280VАС 45-55Hz 45-65Hz > 95% conform to EN > 98% 220/230VAC (± 3%) 220/230/240VAC Pure sine wave < 3% (linear load), < 5% (non-linear load) <2% 50/60Hz (± 0.5%) 50/60Hz (± 0,2%) ± 3% ± 2% 3:1 > 85% VRLA 36VDC (3x7Ah) 96VDC (8x7Ah) 96VDC (8x7Ah) 192VDC (16 batteries) > 10min (with internal batteries) 10-25min (with internal batteries) optional (in external cabinet) Overload, Overheating, Short Circuit, Battery Low, Noise and Spike Suppression 130% for 30 seconds AC-Mode: 120% for 15 minutes Inverter:120% for 30 seconds Sound for Line Failure, Battery Low, - Overload Status, Fault Status Line, Backup, Eco Mode,, Battery Low/Bad/Disconnect, Overload, Fault /, Load %, Battery, Temperature, Error code Internal static (automatic) and manual bypass / External bypass optional EN , EN , EN , FCC Class A IP C 0-90% < 50dB (1m) < 60dB (1m) Option Option 27kg 48kg 53kg 120kg / 183kg (with Battery) 190x465x330mm 190x470x475mm 190x470x475mm 400x730x842mm for Windows, Mac, Linux 2 years (electronics) 40 41
22 External battery On/off switch MARATHON 3/3 Extremely long backup-time! 20kVA/18kW (3/3) On-line Double conversion technology (VFI) Parallel interface RS232/RS485 SNMP external EPO Parallel interface All-in-one solution UPS+Battery+cabinet 20kVA up to 1 ½ hours backup time 40kVA up to 50 minutes backup time fower factor up to 0.99 DSP (Digital Signal Processor) technology Internal static and manual bypass Tower/rackmount installation Wide input voltage range VAC Parallel connection for 2 units Automatic load sharing for all units in parallel Adjustable 6A charger per module Diesel-genset compatibility Centralized touchscreen LCD-display Various monitoring systems RS232/RS485/Modbus EPO (Emergency Power OFF) Option: SNMP card External maintenance bypass 1 year warranty (electronics) Nominal capacity (kva) / Power (kw) Minimum voltage Maximum voltage Power Factor Waveform Harmoniс distortion Crest factor Efficiency Battery Maximum charging current Additional backup time Backup time Protection / Overload protection Overload more than 150% Alarms - Information Audible alarm LED-Alarm voltage range Standards Certificates Protection class Environment Temperature Humidity Audible noise at 1m Altitude RS232 / RS485 / EPO SNMP Dimensions Dimensions WxDxH Weight 20kVA / 18kW 208VAC 478VAC 40-70Hz >0.99 < 3% (linear load) < 5% (non-linear load) 380/400/415VAC (±2%) Pure sine wave Battery mode: 50/60Hz ±0,2% Utility mode: ± 1/2/4/5/10% of the rated frequency (optional) < 2% (linear load) / < 5% (non-linear load) 3:1 ECO-mode 98% / Normal mode 92% VRLA Optional battery quantity: V (32-40 batteries) 6A External battery cabinet (Option) Depends on the capacity of external batteries Overload, Overheating, Short Circuit, Battery Low, Noise and Spike Suppression 110% - 60min / 125% - 10min / 150% - 1min Immediate shutdown of the UPS Beeping sound for Line Failure, Battery Low, - Overload Status, Fault Status Line - Backup - Eco Mode,, Battery Low/Bad/Disconnect, Overload, Fault Big touchscreen display 5" Internal static (automatic) and manual bypass / External bypass optional Max.voltage: +15%(optional +5/10/25% ) / Min. voltage: -45% (optional -20/30%) protection range: ±10% CE, EN (ESD), EN (EMI) IP20 Working temperature: 0-40 C Storage temperature: C 0-95% non condensing <60dB /1m < 1500m Option 483x625x133mm (3U) 31,30kg 42 43
23 VISION MOD 6/10KVA MODULES 6-100kVA (1/1 and 3/1) Centralized LCD Touchscreen Display 6/10kVA Power Module On-line Double conversion technology (VFI) Cabinet for 10 Modules (power modules or battery) up to 100kVA Cabinet for 5 Modules (power modules or battery) up to 50kVA power factor up to 0.99 Internal static and manual bypass in each module (no centralized bypass required) Hot swappable power and battery modules Wide input voltage range VAC Adjustable battery voltage ( VDC, batteries) Only one battery string for N+1 application 6A charging current per module Adjustable charging current Automatic load sharing Diesel-genset compatibility Big touchscreen LCD-display Various monitoring systems Multiple choice of cabinets IP20 to IP55 High overload capacity Low noise RS232/RS485 Relay card (dry contacts) EPO (Emergency Power Off) Options: SNMP card 1 year warranty (electronics) Nominal capacity (kva) / Power (kw) per module Rated voltage range Power Factor Current THDi Harmoniс distortion Crest factor Efficiency Battery Maximum charging current Additional backup time Protection / Overload AC-Mode Overload Battery Mode Overload Mode Alarms - Indication Audible alarm LED-Alarm voltage range Standards Certificates Protection class Environment Temperature Humidity / Altitude Audible noise at 1m In the cabinet In the module Optional Dimensions of the module Dimensions WxDxH Weight Dimensions of the battery module Dimensions WxDxH Weight Dimensions of the cabinet Dimensions WxDxH Weight 6kVA / 4,8kW 380/400VAC or 220/230VAC VAC (3/1) or VAC (1/1) 40-70Hz >0.99 < 5% (at 100% non-linear load) 220/230VAC ±2% with pure sine wave 50/60Hz ±0,2% < 2% (linear load) / < 5% (non-linear load) 3:1 ECO-mode 98% / Normal mode 90% 10kVA/8kW VRLA Optional battery quantity: 192/216/240V (16-20 batteries) 6A per module (can be set according to battery capacity installed) Internal batteries for short backup time or external battery cabinet for long backup Overload, Overheating, Short Circuit, Battery Low, Noise and Spike Suppression 110% - 60min / 125% - 10min / 150% - 1min 110% - 30sec / 125% - 1sec / 150% - 200msec Breaker 40A Breaker 60A Beeping sound for Line Failure, Battery Low, - Overload Status, Fault Status Line - Backup - Eco Mode,, Battery Low/Bad/Disconnect, Overload, Fault Big touchscreen display 5" Internal static (automatic) and manual bypass / External bypass optional Max.voltage: +15%(optional +5/10/25% ) / Min. voltage: -45% (optional -20/30%) protection range: ±10% CE, EN (ESD), EN (EMI) IP20 Working temperature: 0-40 C / Storage temperature: C 0-95% non condensing / < 1500m <50dB /1m according to EN RS232 / RS485 / 2 free slots / dry contacts / EPO RS232 SNMP-Adapter 6kVA / 4,8kW 10kVA/8kW 443x580x131mm (3U) 443x580x131mm (3U) 23kg 25kg Module for 18 pcs 7Ah (for 6/10kVA) Module for 18 pcs 9Ah (for 6/10kVA) 443x580x131mm (3U) 443x580x131mm (3U) 52kg (without batteries 13,5kg) 60kg (without batteries 13,5kg) for max. 5 modules 6/10kVA for max. 10 modules 6/10kVA 600x840x1400mm 600x840x2000mm 150kg 213kg 44 45
24 VISION MOD 20KVA MODULES kVA (3/3) Centralized LCD Touchscreen Display On-line Double conversion technology (VFI) 20kVA Power Module Cabinet for 10 Modules (power modules or battery) up to 200kVA Cabinet for 5 Modules (power modules or battery) up to 100kVA power factor up to 0.99 DSP (Digital Signal Processor) technology Power Factor 0.9 Internal static and manual bypass in each module (no centralized bypass required) Hot swappable power and battery modules Wide input voltage range VAC Adjustable battery voltage ( VDC, batteries) Only one battery string for N+1 application 6A charging current per module Adjustable charging current Automatic load sharing Diesel-genset compatibility Big touchscreen LCD-display Various monitoring systems Multiple choice of cabinets IP20 to IP55 High overload capacity Low noise RS232/RS485 Relay card (dry contacts) EPO (Emergency Power Off) Options: SNMP card Nominal capacity (kva) / Power (kw) per module Rated voltage range Power Factor Current THDi Harmoniс distortion Crest factor Efficiency Battery Maximum charging current Additional backup time Protection / Overload AC-Mode Overload Battery Mode Overload Mode Alarms - Indication Audible alarm LED-Alarm voltage range Standards Certificates Protection class Environment Temperature Humidity / Altitude Audible noise at 1m In the cabinet In the module Optional Dimensions of the module Dimensions WxDxH Weight 20kVA / 18kW 380/400/415VAC VAC 40-70Hz >0.99 < 3% (at 100% non-linear load) 380/400/415VAC ±2% with pure sine wave 50/60Hz ±0,2% < 2% (linear load) / < 5% (non-linear load) 3:1 ECO-mode 98% / Normal mode 92% VRLA Optional battery quantity: V (32-40 batteries) 6A per module (can be set according to battery capacity installed) Internal batteries for short backup time or external battery cabinet for long backup Overload, Overheating, Short Circuit, Battery Low, Noise and Spike Suppression 110% - 60min / 125% - 10min / 150% - 1min 110% - 30sec / 125% - 1sec / 150% - 200msec Breaker 40A Beeping sound for Line Failure, Battery Low, - Overload Status, Fault Status Line - Backup - Eco Mode,, Battery Low/Bad/Disconnect, Overload, Fault Big touchscreen display 5" Internal static (automatic) and manual bypass / External bypass optional Max.voltage: +15%(optional +5/10/25% ) / Min. voltage: -45% (optional -20/30%) protection range: ±10% CE, EN (ESD), EN (EMI) IP20 Working temperature: 0-40 C / Storage temperature: C 0-95% non condensing / < 1500m <60dB /1m according to EN RS232 / RS485 / 2 free slots / dry contacts / EPO RS232 SNMP-Adapter 20kVA / 18kW 443x580x131mm (3U) 31kg 1 year warranty (electronics) Dimensions of the cabinet Dimensions WxDxH Weight for max. 5 modules 600x840x1400mm 170kg for max. 10 modules 600x840x2000mm 230kg 46 47
25 Examples Examples for individual solutions Options Options and monitoring Cabinets up to protection class IP55 Cabinet for Premium DSP in protection class IP31 Additional outlets Energy distribution unit with two Schuko-outlets and four IEC-outlets. Rackmount module version with a height of 2 units. Parallel Distribution Box with s A compact distribution box which allows parallel connection of up to four UPS to increase the power and reliability of the system. UPS can be added in a very simple way. The box also has an external bypass module inside, which provides power supply to the load even if the UPS is disconnected for maintenance. VISION Budget with power cut-off feature Developed for a project in Ukraine to meet special legal standards: Microprocessor controlled power cut-off when reaching the maximum consumed power. Remote control panel The remote control panel is physically connected with the UPS (by cable) and allows distant monitoring and management of the system. The panel can be installed as far as 500m from the UPS and will be power supplied by the interface cable. "Outdoor UPS" UPS with special cabinet in protection class IP55, working at a temperature from -30 up to +50 degrees NetFeeler Temperature/Humidity/Water sensor Wireless smoke sensor Magnetic contact sensor Hybrid Solar UPS UPS for mains-solar application with battery-backup. The UPS can be supplied by solar panels and the mains. The sensors are connected to the three-port-snmp-adapter, offered by VISION UPS. They are mostly used in server cabinets and for the observation of buildings. Very easy installation and adjustment. Split- Hybrid Solar UPS Mains Alternative input for the UPS which allows the use of an additional power source, which works independently from the first power source (for example mains and diesel genset). Solar panels + - Electrical installation Additional chargers (internal/external) For batteries of higher capacity and faster time of recharge Backup load (max. 3000W) 48 49
26 Options Options and monitoring Monitoring Monitoring UPS Management-software by VISION Galvanic isolation transformer The high-quality online UPS of VISION can be provided with a galvanic isolation transformer, which means that the electric circuits before and after the UPS are not connected physically, but via an electromagnetiс field. This increases the reliability of the protection essentially. The UPS-Management Software is a client/server application for networks and local workstations. The UPS-Management Software is connected with the UPS by RS-232/485/USB cable. The software collects the messages sent from the UPS as a background program. Spikes and disturbances can not pass the galvanic isolation transformer. External External manual bypass modules allow service and maintenance work without interruption of the power supply. The UPS can be disconnected after the power supply was switched to the bypass line. If the software detects voltage variations or a power loss it can execute different system event routines, which, for example, may shutdown the server or send warnings to connected users. These system event routines, which are part of the UPS-Management Software, are fully customisable. You can program UPS-Routines (e.g. define dates for automatic UPS-tests, shutdown the system at defined dates, etc.), check the status of the UPS, execute different UPS tests or create power quality statistics. You can also constantly monitor and evaluate the event protocol (log file) that is permanently updated. It is also possible to provide a simultaneous shutdown of several servers that are all supported by the same UPS. - Low battery warning, on-screen backup time, battery time countdown, Low bat- Web/SNMP-Adapter SNMP-Adapters provide monitoring of the UPS via Ethernet. The monitoring software allows connection with one or more UPS by means of the individual IP-adress every UPS gets. Monitoring and control can be made distantly. For example all servers in a network can be shutdown. Afterwards all servers can be started up by Wake-up-on-LAN. SMS can be sent without LAN-connection by using a GSM Modem. tery warning, UPS temperature such as battery and internal temperature, defect battery warning, time and date stamp event logging, extensive logging of all UPS activity and user messaging. - Battery management, surveillance and counter for power events. - SMTP compatible system with messaging service for , to SMS or other external services. - Client/server software for heterogeneous networks with one and three-phased UPS. - "Look & feel" is identical on all platforms. - Integrated SNMP agent for NetWare, MS -WINDOWS NT/2000, Linux and SUN - Supports all important network protocols for the graphical control of the UPS from every Windows Station in the network. Relay card / AS400 / Modbus Relay cards are based on dry contacts and give signals in the case of power supply interruption, switching to bypass or general faults. The AS400 and ModBus card provide the interface for the corresponding protocols. - Automatic unattended shutdown of local and remote computers in networks (Master/Slave via RCCMD module) - Selftest functions, such as economy mode, UPS temperature, battery load, power socket switching and UPS emergency cut-off. - Shutdown and test functions can be executed with a Scheduler - Graphic display of quality of incoming power load frequency in minimum-maximum or average values. IEC to Schuko converter with 3 outlets For additional Schuko outlets Software made by Generex and MegaTec
27 Service and warranty Service and warranty Optimal service in all stages References References Some of our partners and projects The philosophy of VISION attends to a long-term joint operation in service and technical support. It means exactly: Training VISION offers its customers free courses, where managers or technicians can get to know all details of our production. Designing Siemens Luxembourg ABB Luxembourg Caterpillar (France) Total Group In common with its clients VISION UPS develops custom elaborations, which have a lot of modifications and individual configurations due to their great flexibility. Installation and maintenance VISION UPS in addition to standard instructions - specified technical documentations for installation and maintenance its devices, what makes it Toshiba Medical Systems Orange ESA (European space agency) Goodyear possible for technicians to save time on-site and minimize sources of error. Besides, the specialists of VISION are always disposable for fast consultations. During and after the term of warranty VISION UPS considers to be responsible for an uninterpretable functioning of its devices during and after the term of warranty. That is why we offer technical support at any time. Rapid and effective problem solving from VISION per , Skype, ICQ, phone is appreciated in all over the world first of all in the regions, which are far from big populated areas. Rexel European court BNP Paribas France Telecom Aspex (Phillipines) African Energy Administration of France, Reunion PSS (Romania) Warranty Line Interactive UPS: 2 years Online UPS (1/1): 2 years Online UPS (3/1 & 3/3): 1 year Converters AC-DC and DC-AC: 2 years : 2 years (also in UPS): 1 year IOE (Bangladesh) Global Broadband Extor (Hungary) Headset (Portugal) DHL Germany Mabis (Spain) Avecom (Germany) International Connect (USA) Replacement of batteries: The availability of commodities in our storehouse makes it possible for us to replace batteries in a short time for all types of UPS. Kievstar (Ukraine) RADIUS VIP (Russia) Wesemann (Netherlands) Ensilitec (Austria) 2012 VISION UPS SYSTEMS S.á.r.l. All Rights Reserved. Non contractual document. The technical data can be varied without prior notice. The imperfect description of certain data or information cannot be excluded
28 NOTES NOTES 54 55
29 NOTES NOTES 56 57
30 VISION UPS UPS PRODUCT CATALOGUE
PowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
Galleon 6-10K Online UPS. Voltronic Power Technology Corporation
Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS, Sine
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V
LAP ENERGIA PARA DATACENTERS
LAP ENERGIA PARA DATACENTERS Latin American Power. CABA, Argentina. 2 UPS INDOOR Latin American Power. CABA, Argentina. ALI ELITE SERIES Line Interactive UPS Tower/19 Rack Mount Versions 19 Rack Mount
SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMX750SLT Highlights 750VA line interactive tower UPS; Sine wave output 220/230/240V nominal
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS,
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA -3000VA Intelligent, Reliable UPS Protection Liebert
SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial
SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMART500RT1U Description Tripp Lite's SMART500RT1U intelligent, line-interactive rack/tower uninterruptible
UNINTERRUPTIBLE POWER SUPPLY (UPS)
Your Inspirations. Our Innovations. UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting Your Data CATALOGUE Revision 0 Table of Contents Table of Contents About Us - Company Profile Online UPS Professional
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SM1000RM1UTAA Description Tripp Lite SM1000RM1UTAA 1000VA / 1kVA / 800 watt line
TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS
Capacity Technology Inverter Technology Noise Level Operating Temperature Humidity Harmonic Distortion Total DC bus voltage Battery recharge time (After Complete discharge) to 100% charge Crest Factor
Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE
Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication
30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial
SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1000RT2U Highlights 1kVA / 1000VA / 900W line-interactive 2U rack/tower UPS, Sine
on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications
ZP110 on-line UPS 1, 2, 3, 6, 10kVA single/single phase LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs Emergency Devices (Lights/Alarms) Electro-Medical Devices
Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8
Door Mount UPS (Patent Pending) Shelf Mount UPS (Patent Pending) DESCRIPTION: The Always On NDM (door mount) and NSM (shelf mount) Series UPS s are dual conversion online UPS systems provided in slim,
RIELLO ELETTRONICA. Master HP
RIELLO ELETTRONICA Master HP LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCS ELECTRO- MEDICAL DEVICES
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial MODEL NUMBER: SMART1500SLT Highlights 1.5kVA / 1500VA line interactive tower UPS; Sine wave output
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
Model #: SMART2200CRMXL
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: [email protected] Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for
DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.
Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier
APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply
APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port MODEL NUMBER: OMNIVS1500 Highlights 1500VA / 1.5kVA tower 120V line-interactive UPS Corrects brownouts and overvoltages from 75 to 147V
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
MAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR
PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR CLASSIFICATION CLASSIFICATION ACC. TO - AEG S UPS PRODUCT PORTFOLIO - IT S APPLICATION ORIENTED USE - UPS PRODUCT
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,
Options and monitoring
Additional outlets Energy distribution unit with two Schuko-outlets and four IEC-outlets. Rackmount module version with a height of 2 units. Parallel Distribution Box with Bypasss A compact distribution
Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System
Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System MODEL NUMBER: HTR05-1U Description Tripp Lite's HTR05-1U AVR Series intelligent, Automatic Voltage Regulated
LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase.
LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro online UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase LOCAL AREA NETWORKS (LAN) INTERNET CENTERS (ISP/ASP/POP) ELECTRO-MEDICAL
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES
UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES 9900A The 9900A UPS system uses the most advanced IGBT in both the converter and inverter with Digital Signal Processor (DSP)
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets MODEL NUMBER: BC600SINE Highlights 600VA tower 120V standby UPS with SINE WAVE output Maintains AC output during power
Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0
The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,
Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V
SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79
Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V
Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V APC Smart-UPS, 670 Watts / 1000 VA,Input 230V / Output 230V, Interface Port DB-9 RS-232, SmartSlot, USB Includes: CD with software, Smart UPS signalling
Assembled in Florida, USA.
*some models Assembled in Florida, USA. Check our online UPS section at: www.olinsys.com/ups Descubra nuestra sección online de UPS en: www.olinsys.com/ups UPS Uninterruptible Power Supply / Alimentación
Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA
Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA Liebert GXT3 is a full feature UPS providing reliable protection for IT network equipment and data centers. It is a true
Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications
W H I T E P A P E R Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications Executive Summary One of the fundamental decisions in the design of data centers, server rooms
GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work
GE Consumer & Industrial Power Protection UPS Uninterruptible Power Supplies GE imagination at work For more than a century, GE has led the way with innovative technologies and groundbreaking quality initiatives
NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
NIKY and NIKY S UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Niky S line interactive Sinusoidal output Microprocessor control MODEM/LAN telephone
4.0 UPS dedicated to ICT for unmatched energy savings
4.0 UPS dedicated to ICT for unmatched energy savings Introducing UPSaver by Borri, a new modular UPS series for the ICT industry, totally configurable, quickly scalable, with high efficiency and low TCO.
Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system
Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system Model #: SMART500RT1U 500VA line interactive 1U rack/tower UPS 7 outlets with 1 switchable load bank Simultaneous
3U, 2200 VA Audio/Video Pure Sine Wave UPS System
3U, 2200 VA Audio/Video Pure Sine Wave UPS System MODEL NUMBER: HTR22-3U Description Tripp Lite's HTR22-3U Pure Sine Wave 2200VA/1600W on-line, double-conversion UPS system prevents media data loss, equipment
Online UPS. PowerWalker VFI 1000R/1U
Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.
APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply
APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of
City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION
City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION This Appendix A includes technical documents and specifications for the Toshiba 4200 FA 30 kva Uninterruptable Power
UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES INDEX General characteristics page 4 Modular page 12 Conventional page 32 Line-interactive page 44 Communication
Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw
Tender Technical Specification For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw 1 di 14 Index 1 GENERAL REQUIREMENTS... 4 1.1 SUBJECT AND AGREEMENT TYPE... 4 1.2 CONDITIONS... 4 2 GENERALI
Internet Office 500VA Tower Standby 120V UPS with USB port
Internet Office 500VA Tower Standby 120V UPS with USB port MODEL NUMBER: INTERNETOFFICE500 Highlights 500VA tower 120V standby UPS Maintains AC output during power failures 3 UPS battery supported outlets,
Uninterruptible Power Supplies. Section 20. www.geindustrial.com BuyLog Catalog 20-1
Power dependency has increased dramatically in the new business environment based on e-commerce applications, mobile networks, corporate Internet sites, e-pay and networked IT structures. Near one-hundred
10000HXL31/15000HXL31/20000HXL31
Table of Contents www.eaton.com/dxups USER MANUAL ON LINE UPS 10000HXL31/15000HXL31/20000HXL31 Uninterruptible Power Supply Table of Contents 1. Brief introduction 1.1 System and model description---------------------------------------------------------------------1
Internet Office 750VA Ultra-compact Standby 120V UPS with USB port
Internet Office 750VA Ultra-compact Standby 120V UPS with USB port MODEL NUMBER: INTERNET750U Highlights 750VA ultra-compact 120V standby UPS Maintains AC output during power failures 6 UPS battery supported
User Manual 1K/2K/3K Online UPS
User Manual 1K/2K/3K Online UPS Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4. Operation...
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Back-UPS 650 VA 120 V with AVR (BX650CI-LM)
Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit
GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work
GE Consumer & Industrial Power Protection Digital Energy LP Series UPS Uninterruptible Power Supply 3-30 kva GE imagination at work For more than a century, GE has led the way with innovative technologies
GE Digital Energy. TLE Series UPS. 160-400 kw three phase 400 Vac. with best-in-class efficiency. gimagination at work
GE Digital Energy TLE Series UPS 160-400 kw three phase 400 Vac with best-in-class efficiency gimagination at work GE provides clean, efficient and reliable power for today s digital world with the ultra
Tough Decision: On-Line or Line-Interactive UPS?
W H I T E P A P E R Tough Decision: On-Line or Line-Interactive UPS? How to Choose the Right Protection for Your Network Executive Summary In today s data-driven, technology-dependent world, no organization
USER MANUAL Online UPS 1K/2K/3K
USER MANUAL EN Online UPS 1K/2K/3K Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1.1. Transportation 2 1.2. Preparation 2 1.3. Installation 2 1.4. Operation 2 1.5.
BC Pro UPS System Standby UPS System
BC Pro UPS System Standby UPS System Model #: BCPRO1400 1400VA standby, tower UPS system Offers battery derived AC output during blackouts and brownouts starting at 99V 6 protected AC outlets (NEMA 5-15R)
BB800 Off-Grid Solar System
BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry
The UPS for the highest security in industry and data centres
The UPS for the highest security in industry and data centres P R E M I U M 6,000-20,000VA T E C H N O L O G Y www.online-usv.de Perfect: The ultimate protection against blackout and data loss The new
APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply
APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality
Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual
Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6 User s manual Index Safety Warnings... 2 1 Introduction... 3 2 General Characteristics... 4 3 Receipt and site selection... 4 4 EXTERNAL
Galaxy VM. Three-phase power protection. schneider-electric.com
Galaxy VM Three-phase power protection schneider-electric.com 2 schneider-electric.com schneider-electric.com 3 Galaxy VM trusted partner for your business continuity Features and benefits Highly efficient,
TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency
GE Critical Power TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency imagination at work GE provides clean, efficient and reliable power for today s digital world with the
For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on
Home Sign In View Cart Order Status Search Solutions Products and Services Support Your Business Company Data Center Server Rooms Solutions for Small-Medium Data Center Large Data Centers Cloud & Co-location
TLE Series. Product Description. 160-200-320-400 kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES
TLE Series Product Description 160-200-320-400 kva / 400Vac / S1 KEY BEEFIT High efficiency up to 96.5% in on-line double conversion and 99% in eboost operation mode Unity output power factor; full power
Eaton 93PM UPS Where aesthetics meet intelligence.
Brochure 100 kw Eaton 93PM UPS Where aesthetics meet intelligence. 93PM features and benefits The Eaton 93PM UPS combines unprecedented and reliability with eye-catching design. A space-saving, flexible
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Introduction There is a growing trend in the UPS industry to create a highly efficient, more lightweight and smaller UPS
Smart-UPS On-Line 230 V
Smart-UPS On-Line 230 V Unity output power factor single-phase, double-conversion online UPS with advanced management features A versatile UPS developed for unstable power conditions worldwide Smart-UPS
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
MGE Galaxy 7000. 160/200/250/300/400/500 kva Power efficiency for business continuity
MGE Galaxy 7000 160/200/250/300/400/500 kva Power efficiency for business continuity Performance three-phase power protection with high adaptability to meet the unique requirements of medium to large data
Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course. 2008 Tripp Lite.
Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course. 2008 Tripp Lite. All rights reserved. The policy of Tripp Lite is one of continuous
Specification Requirements DBL 700MX and 1000MX Series UPS
Specification Requirements DBL 700MX and 1000MX Series UPS Theory of Operation Upon loss of utility power, the UPS inverter shall continue to provide seamless pure sine-wave AC from the batteries without
NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.
NEW APC Smart-UPS Advanced line interactive power protection for servers and network equipment. > The world s most popular network and server UPS. Award-winning Smart-UPS protects critical data by supplying
USER MANUAL Online UPS 1K/2K/3K Rack
USER MANUAL EN Online UPS 1K/2K/3K Rack Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation 2
Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA
the Mega Power protection up to 5.4 MVA range is capable of a maximum system size of up to 5.4 MVA and specifically designed for demanding Data centre applications such as large DTC of banks / insurances,
TOSHIBA G9000 80/100/160/225 kva
CORPORATE OFFICE 13131 WEST LITTLE YORK ROAD HOUSTON, TX 77041 PHONE: (713) 466-0277 (800) 231-1412 FACSIMILE: (713) 896-5226 TOSHIBA G9000 80/100/160/225 kva GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE
Power Quality Solutions up to 40 kva. UPS product catalogue
Power Quality Solutions up to 40 kva UPS product catalogue Power Quality Contents Eaton Power Quality Division, a part of the Electrical Sector, has more than 45 years of experience in designing and producing
Technical Specification Kohler PW 5000/TP
Technical Specification Kohler PW 5000/TP Pioneering solutions for total power protection 2 UPS472-01-01 Kohler PW 5000/TP Technical Specification Dated 17-11-2011 Kohler PW 5000/TP SYSTEM DESCRIPTION
Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
SD Series. SD Series Rectifiers. EPC Energy & Power Conversion
Rectifiers Microprocessor controlled rectifier technology Fully adjustable float, boost and equalizing charge modes with V/I characteristic Advanced technology for phase control Verylowvoltage ripple and
Line Interactive UPS
EN Line Interactive UPS PowerMust 636 LCD (650VA), Line Int., Schuko PowerMust 848 LCD (850VA), Line Int., Schuko PowerMust 636 LCD (650VA), Line Int., IEC PowerMust 848 LCD (850VA), Line Int., IEC PowerMust
SG Series UPS 10-600 kva three phase 400 Vac
GE Critical Power SG Series UPS 10-600 kva three phase 400 Vac with ultra-high efficiency eboost TM technology imagination at work From protecting assets such as generators, transmission lines and motors,
User s Manual AURORA 1.2K/2.2K
User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable
NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.
NEW APC Smart-UPS Advanced line interactive power protection for servers and network equipment. > The world s most popular network and server UPS. Award-winning Smart-UPS protects critical data by supplying
Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.
Line Interactive UPS PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID Quick Start Guide CONTT IMPORTANT SAFETY INSTRUCTIONS... 1 1. Introduction... 4 2.
GE Digital Energy. SG-CE Series UPS. 60-500 kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work
GE Digital Energy SG-CE Series UPS 60-500 kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work From protecting assets such as generators, transmission lines and motors, to ensuring
emcomp s.r.o. G E D ig ita l E n e rg y Stolní záložní zdroje VICTRON GE Digital Energy ML/Match - Pluggable single phase line-interactive UPS
ML/Match - Pluggable single phase line-interactive UPS s including batteries, bundled with software, three years warranty EU EU ML Series: step wave, 2-LED front, RS232 Match: sine wave, 6-LED front incl.
Dell Smart-UPS 1,500 3,000 VA
Dell Smart-UPS,00,000 VA 0 V Advanced line interactive power protection for servers and network equipment Reliable. Intelligent. Efficient. Manageable. Engineered by APC by Schneider Electric, the Dell