Technical Specification Kohler PW 5000/TP
|
|
|
- Merilyn Tabitha Douglas
- 10 years ago
- Views:
Transcription
1 Technical Specification Kohler PW 5000/TP Pioneering solutions for total power protection
2 2 UPS Kohler PW 5000/TP Technical Specification Dated
3 Kohler PW 5000/TP SYSTEM DESCRIPTION The availability of protected and continuous power is essential in today s dynamic IT and process-related environments, where demands can change rapidly through the introduction of new server technologies, migration and centralisation. In environments such as these, not only must the power protecting equipment be reliable but it must also be resilient and easily adaptable to suit changing load requirements attributes that are readily apparent in the Kohler PW 5000/TP series Uninterruptible Power Supply (UPS). The Kohler PW 5000/TP represents a completely new generation of mid-range, 3 phase UPS systems, incorporating the latest technological developments in power engineering. Its advanced double conversion, Voltage and Frequency Independent (VFI), topology fully satisfies the highest availability and environmentally-friendly requirements compliant with IEC (VFI-SS-111) standards. High reliability, upgrade ability, low operating costs and excellent electrical performance are just some of the highlights of this innovative UPS solution. The Kohler PW 5000/TP is designed to respond to the most stringent safety, EMC and other important UPS standards. Kohler PW 5000/TP is a stand-alone UPS module available in seven power ranges: 10, 15, 20, 25, 30, 40 & 50 kva. Each Kohler PW 5000/TP module can operate as a stand-alone UPS, or up to 20 units can be connected in parallel to operate as a multi-module UPS system. A parallel system configuration is generally chosen either to increase the system s total output power capacity, or to provide module redundancy to enhance the overall system reliability. When operating in a parallel system, each UPS module can assume the paralleling control leadership role which avoids a single point of failure in the parallel chain and ensures the highest level of reliability. Note: Although the UPS single/multi configuration can be modified in the field it is generally specified on ordering so that the module can be configured and fully tested in the factory prior to despatch. The most demanding IT infrastructures begin with low power requirements which gradually increases as it builds up to full capacity. To avoid putting the load at risk, it is essential to be able to increase the amount of available power as the infrastructure grows. The modular design of the Kohler PW 5000/TP system allows the parallel configuration to be expanded to cater for increasing load demands without interrupting the load or temporarily transferring it to an unprotected bypass supply. This Technical Specification provides detailed technical information on the mechanical, electrical and environmental performance of the Kohler PW 5000/TP that can support and give answers to tender and end user requirements. KEY FEATURES Best-in-class efficiency Compact size, small foot print Blade-server-friendly power; full power from 0.9 lead to 0.73 lag Very low input current harmonic distortion THDi = load Input Power Factor near unity Energy-Operational cost savings (TCO) Expensive floor space savings No de-rating required with leading PF loads Gen-set power and installation cost savings Cost savings during installation and the entire life cycle (TCO) UPS Kohler PW 5000/TP Technical Specification Dated
4 GENERAL SPECIFICATIONS MECHANICAL CHARACTERISTICS UPS CABINET A (without battery enclosure) Dimensions (WxHxD) mm 345 x 720 x 710 Weight without battery kg Weight with 48x7/9Ah battery kg Weight with standard packaging kg +4 Colour Graphite grey (RAL 7024) UPS CABINET B (without battery enclosure) Dimensions (WxHxD) mm 345 x 1045 x 710 Weight without battery kg Weight with 96x7/9Ah battery kg Weight with standard packaging kg +5 Colour Graphite grey (RAL 7024) UPS CABINET C (without battery enclosure) Dimensions (WxHxD) mm 440 x 1420 x 910 Weight (7/9Ah cab without battery) kg Weight (28Ah cab without battery) kg Weight with 144x7/9Ah battery kg Weight with 48x28Ah battery kg Weight with standard packaging kg +5 Colour Graphite grey (RAL 7024) INPUT CHARACTERISTICS Nominal Input Voltage V 3x380/220V+N, 3x400V/230V+N, 3x415/240V+N Input Voltage Tolerance (ref to 3x400/230V) for Loads in %: V (-23%/+15%) 3x308/177 V to 3x460/264 V for <100% load (-30%/+15%) 3x280/161 V to 3x460/264 V for < 80% load (-40%/+15%) 3x240/138 V to 3x460/264 V for < 60% load Input Frequency Hz Input Power Factor 100% load Inrush Current A max. In Input Distortion THDi Sine-wave THDi = 100% load Max. Input Power with rated output power and charged battery (output pf = 0.9) Max. Input Current with rated output power and charged battery (output pf = 0.9) Max. Input Power with rated output power and discharged battery (output pf = 0.9) Max. Input Current with rated output power and discharged battery (output pf = 0.9) kw A kw A UPS Kohler PW 5000/TP Technical Specification Dated
5 OUTPUT CHARACTERISTICS Output Rated Power KW Output Current p.f. 0.9 (400 V) A Output Current p.f. 1.0 (400 V) A Output Rated Voltage V 3x380/220V or 3x400/230V or 3x415/240V Output Voltage Stability % Static: < ±1% Dynamic (Step load 0%-100% or 100%-0%) < ±4% Output Voltage Distortion % With Linear Load < 2% With Non-linear Load (EN :2001) < 4% Output Frequency Hz 50 Hz or 60 Hz Output Frequency Tolerance Deg. Synchronized with mains < ±2% (selectable for bypass operation) or < ±4% Free running ±0.1% Bypass operation At Nominal Input voltage of 3x400 V ±15%, or 196 V to 264 V ph-n Permissible Unbalanced Load (All 3 phases regulated independently) % 100% Phase Angle Tolerance (With 100% Unbalanced load) Deg. ±0 deg. Overload Capability on 0.8 p.f. % 125% load 10 min. 150% load 1 min. Overload Capability on 0.9 p.f. % 110% load 10 min. 130% load 1 min. Output short capability (RMS) A Inverter: up to 3 x In during 40 ms Bypass: 10 x In during 10 ms Crest - Factor 3: 1 BATTERY CHARACTERISTICS Cabinet Type A B A B A B B C C C C Maximum Battery Charger Current 4A 6A Battery Charging Curve Ripple free; IU (DIN 41773) Temperature compensation ready Standard (temp. sensor optional) Battery Test Automatic and periodically (adjustable) Battery Type Maintenance free VRLA or NiCd Min/Max Number of 12V Battery Blocks per string 22-50* 32-50* 32-50* 40-50* 24-50* 32-50* 40-50* * Depending on the effective load in kw used by the system (numbers shown are for pf only) UPS Kohler PW 5000/TP Technical Specification Dated
6 HEAT DISSIPATION (Non-linear Loads) Heat Dissipation with 100% Non-linear Load per range (EN ) Heat Dissipation with 100% Non-linear Load per range (EN ) Airflow (25 C - 30 C) with 100% Non-linear Load per range (EN ) W BTU /h m³/h Heat Dissipation without load W ENVIRONMENTAL Audible Noise with 100% / 50% Load dba 55/49 55/49 57/49 57/49 58/50 59/50 59/50 Operation temperature C 0-40 Ambient Temperature for Batteries (recommended) C 20 Storage Temperature C Between -25 and +70 Battery Storage Time at Ambient Max. 6 months Temperature Max. altitude (above sea level) m 1000m (3300ft) without de-rating De-rating factor for use at altitudes ALL MODULES above 1000m sea level according (IEC ) Metres above sea level (m / ft) De-Rating Factor for Power 1500 / / / / Relative Air-humidity Max. 95% (non-condensing) Positional Clearances Front: A minimum of 900mm should be allowed for free passage. Side: 600mm left and right side access is required for service. Rear: A minimum of 200mm is required for cooling air circulation and the unit should be cabled such that it can be pulled forward to allow 600mm rear clearance for service/maintenance. Accessibility (Operator) 10kVA 25kVA in type A or B cabinets require front/rear access 25kVA 50kVA in type C cabinets require front access only Input and Output Power Cabling 10kVA 25kVA in type A or B cabinets are cabled at the rear 25kVA 50kVA in type C cabinets are cabled at the front Efficiency AC-AC up to (at pf=1.0) Load: 100% 75% 50% 25% (depending on UPS power) Efficiency: 95.5% 95.5% 95% 94.5% Eco-Mode efficiency at 100% load % 98% 6 UPS Kohler PW 5000/TP Technical Specification Dated
7 STANDARDS Safety Electromagnetic Compatibility EMC Classes C2 domestic or industrial In < 16A C3 industrial In >16A IEC/EN :2003, IEC/EN :2001/A11:2004 IEC/EN :2005, IEC/EN :2000, IEC/EN :2001, Performance IEC/EN :2001 Product certification CE Degree of protection IP 20 C2 C3 COMMUNICATION OPTIONS STANDARD ITEMS Power Management Display (PMD) LCD display and mimic diagram showing UPS operational status JD1 RS232 on Sub-D9 port For monitoring and integration in network management X1 Customer Interfaces: Inputs (DRY PORTS) 1 Remote Shut down [EMERGENCY OFF (Normally closed)] 1 GEN-ON (Normally open) 1 Programmable Customer's Inputs (Normally open) 1 Battery Temperature Sensor for enhanced battery charging control 1 12Vdc source (max. 250mA) to supply remote monitor JR1 RJ45 port For multidrop purpose (optional) OPTIONAL ITEMS Relay card +USB Including: X2 Customer Interfaces: Outputs (DRY PORTS) RS232 on USB Port SNMP Card (slot already included) Common Alarm Load on Bypass Battery Low Load on Inverter Mains Failure For remote signalling and automatic computer shutdown For monitoring and integration in network management UPS Kohler PW 5000/TP Technical Specification Dated
8 COMMUNICATION OPTION DETAILS Power management display (PMD) Mimic Diagram LCD Display Panel Operator Keys The user-friendly Power Management Display provides access to all monitoring information and operator controls. Mimic Diagram The mimic diagram contains multi-coloured LEDs that change between Green, Red and Off to indicate the UPS operation and power flow status. LEDs LINE 1 and LINE 2 indicate the availability of the input mains and bypass mains power supplies respectively, and are both Green during normal operation. The INVERTER and BYPASS LEDs indicate which of the two power sources is providing the critical load supply. These LEDs illuminate Green to indicate which is the active supply source. The BATTERY LED indicator is a solid Green when the battery is being charged and flashes when the battery is discharging e.g. when it is providing the load power following a mains failure. The ALARM LED, located at the lower-centre area of the PMD, is a visual indication of any monitored internal or external alarm condition. When activated, it is accompanied by an audible alarm that can be cancelled by pressing the RESET button. LCD Display Panel The 2 x 20 character multi-function LCD Display is menu-driven using the UP, DOWN and ENTER keys. It provides a simple communications interface that enables the operator to monitor important UPS operating parameters and alarm warnings, and effect various control operations such transferring the load between the inverter and bypass. LCD Display Panel summary: Displays the input and output voltage, current, frequency and power Displays an Event register which stores a date/time stamped history of the 99 most recent alarms Enables battery run time monitoring Enables selection of commands such as UPS Start-up and Shut-down, Load transfer from inverter to bypass and vice-versa Provides diagnostic facilities (service mode only) In conjunction with the operator keys, provides UPS adjustments and testing facilities (service mode only) JD1 Smart Port Serial RS 232 and USB Port JD1is a standard D-Type, 9-pin, female socket, and the USB is a standard USB port. The SMART PORT is an intelligent RS 232 serial port that allows the UPS to be connected to a computer. When used in conjunction with the optional SMART PORT software, WAVEMON, it enables the computer to continuously monitor the mains voltage and UPS-status, and display a message in the event of any UPS system changes. 8 UPS Kohler PW 5000/TP Technical Specification Dated
9 X1 Dry Port (volt-free contacts) All the input and output interface connections to X1 are made to Phoenix terminals (cable 0.5mm²) Connection of Remote Shut down facilities, Generator Operation, Customers specials. Terminal Contact Signal Function X1/1 In +12Vdc GENERATOR OPERATION X1/2 Gnd Gnd (NC = Generator ON) X1/3 In +12Vdc Customer IN 1 X1/4 Gnd Gnd (Function on request, to be defined) X1/5 In +3.3Vdc BATTERY TEMPERATURE X1/6 Gnd Gnd If connected, the battery charger current is temperature dependent X1/7 In +12Vdc REMOTE SHUTDOWN X1/8 Gnd Gnd Do not remove the factory mounted bridge until an external remote shut down is connected X1/9 In +12Vdc 12Vdc SOURCE X1/10 Gnd Gnd Max 200mA load (e.g. used to power remote indicator panels) JR1 RS485 Interface for multidrop The Computer Interface JR1 is an intelligent RS485 serial port that allows system information to be gained from all modules that are connected in parallel using the Multidrop connection kit. The connector JR1 is a standard RJ45 socket. X2 Dry Port Optional output interfaces terminal block (X2) All the input and output interface connections to X2 are made to Phoenix terminals (cable 0.5mm²) X2 provides status and alarm signal outputs that can be used to initiate orderly shutdown of servers, AS400 or automated building management systems. All signals are provided via voltage free contacts are rated 60 VAC / 500 ma maximum. Pin Contact Signal Function 1 Alarm MAINS_OK Mains Failure 2 Mains Present 3 Common 4 Message LOAD_ON_INV Load On Inverter 5 Load on Mains (BYPASS MODE) 6 Common 7 Alarm BATT_LOW Battery Low 8 Battery OK 9 Common 10 Message LOAD_ON_MAINS Load On Mains (BYPASS-MODE) 11 Load on Inverter 12 Common 13 Alarm COMMON_ALARM Common Alarm 14 No Alarm Condition 15 Common UPS Kohler PW 5000/TP Technical Specification Dated
10 Modem/Ethernet card / PowerREPORTER management software UPS systems Optional Interface Card MODEM SSL INTE RNET Communication Interface (PLC s) 1.10 Management Station Alarm Situation Problem in the System Call back Modem GSM Modem Network interface (ethernet) MODEM Co mmunication Interface (PLC s) INTERNET PowerREPORTER PowerREPORTER is a remote monitoring and management service which is a part of the premium power protection concept. Two solution cards are available to enable connection between the UPS and the outside world: Modem/ Ethernet or Modem/GSM. PowerREPORTER : Provides affordable, continuous monitoring over mission-critical facilities and offers peace-of-mind by detecting and warning of any potential system problems before they become a crisis: Acquires key performance parameters and productivity information in real-time to enable you to better understand machine performance and faster troubleshoot downtime events. Gives total transparent information concerning all actions performed on the system, such as all critical status changes, coordination of equipment service, reporting of all alarms with priorities. Key Features Redundant and secure communication Alarm acknowledgment Priority driven Management (with escalation) Comprehensive Management System Reception and management of alarm calls from UPS Storage of UPS Data in a database exportable in a CSV-format for easy handling in Excel Unlimited number of UPS that can be managed User administration with passwords and permission-level Administration of Log file Data logging with statistical analysis and diagnostics, report Visualization of the UPS data Current status ( single and parallel operation) Measured values for single or three phase Recording function including graphs with zooming capabilities for selected measured values Display of event log file Display of UPS Parameters Web Server functionality, for data access from any Web Browser 10 UPS Kohler PW 5000/TP Technical Specification Dated
11 SNMP card/adaptor for network management/remote monitoring UPS External SNMP Adapter Ethernet Internal SNMP Card The Simple Network Management Protocol (SNMP) is a world-wide standardised communication-protocol that is used to monitor any device in a network via a simple control language. The UPS-Management Software (WAVEMON) provides data in this SNMP format with its internal software agent and can be used with any SNMP compatible operating system. We offer our software with SNMP functionality together with NetWare, OS/2, all Windows NT systems on INTEL and ALPHA. There are two types of SNMP-Adaptors available: External SNMP-Adaptor and Internal SNMP-Card (both have the same functionality). Both can manage a parallel system (N modules) and return either global values which are consistent for the whole parallel system or specific values from the individual modules. The SNMP adaptor requires a PC with terminal connections, and for normal operation at least one network connection (Ethernet) is also required. UPS Kohler PW 5000/TP Technical Specification Dated
12 INSTALLATION PLANNING The following guidelines should be taken into account when planning a suitable UPS location and environment. Location considerations summary The equipment must be installed and transported in a upright position The floor at the installed location and en-route from the off-loading point must be able to safely take the weight of the UPS and battery equipment The floor material where the UPS is to be located should be non-flammable Local fire protection standards must be respected Ensure that appropriate power supplies are available and that UPS cabling can be performed easily The location must be vibration free If the UPS is to be installed in bayed enclosures, partition walls must be installed. Environmental considerations summary Avoid high ambient temperature, moisture and humidity. Humidity (< 90% non-condensing) and temperature (+15 C / +25 C) are within prescribed limits An ambient temperature of 20 C is recommended to achieve a long battery life. Any prescribed air cooling flow must be available. Ensure the air conditioning system can provide a sufficient amount of air cooling to keep the room at, or below, the maximum desired temperature. Ensure no dust or corrosive/explosive gases are present CLEARANCES X Y* V Y* X BATTERY CABINET (option) UPS Front Front Access Space V 600 mm X 600 mm Z Z Y* 200 mm Z 900 mm The above diagram illustrates the recommended clearances to be provided around the UPS and optional Battery Cabinet. Please read the following notes for clarification. Notes 1. The minimum 200mm space shown at the rear of the UPS [Y] is required to allow adequate cooling air flow; however, A and B UPS cabinets are cabled from the rear and the UPS power switches and fuses are located on the back panel. When installing A and B UPS cabinets you should allow sufficient slack in the cabling to pull the UPS cabinet forward or otherwise install the UPS with sufficient rear clearance to allow cable and switch access. 2. The above diagram shows 600mm clearance [V] between the UPS and optional Battery Cabinet. This is necessary to gain side access to the UPS for service repair. In the case of a type A or B UPS cabinet, if the cabling is sufficient to allow the cabinet to be pulled forward clear of the Battery Cabinet (see note 1 above) then it is not necessary to observe clearance [V], and the UPS and Battery Cabinets can be located immediately adjacent to each other. 12 UPS Kohler PW 5000/TP Technical Specification Dated
13 UPS POWER CABLING Cabinets A & B (10-25kVA) All power cables are connected to terminals on the bottom of the UPS Power Board accessed through a removable panel on the lower back of the UPS. Ex. Batt. Earth Input Mains Bypass Mains UPS Output Earth + N PE 1L2 1N 2L2 2N 3L2 3N PE PE 1L1 1L3 2L1 2L3 3L1 3L3 PE Cabinet C (25-50kVA) All power cables are connected to terminal blocks mounted on a DIN rail located in the lower front of the UPS. + N 1L1 1L2 1L3 1N PE 3L1 3L3 PE PE 2L1 2L2 2L3 2N 3N 3L2 PE Terminal Connections Battery (+ / N / - / PE) Input Bypass (3 + N) Input Mains (3+N+PE) Output Load (3+N+PE) Max Cable Section Tightening Torque Cabinets A & B (10-25kVA) 4 x 16mm² 5 x 16mm² 16mm² 1.5 Nm Cabinet C (25-50kVA) 4 x 35mm² 5 x 35mm² 16mm² 3.5 Nm The UPS input/bypass terminals should be connected to the input mains/bypass supply through a LV-Distribution board and protected by a circuit breaker or fuse. This provides overload protection and also a means of isolating the UPS from the mains supply when required. Similarly, the UPS output terminals should be connected to the load equipment via a suitably fused load distribution panel. Note: It is the customer s responsibility to provide all external fuses, isolators and cables used to connect the UPS input and output power supplies. The UPS can be wired with a single feed input (standard), whereby the UPS input supply is internally connected to the UPS bypass circuit, or it can be wired with a dual feed input (shown above) where the UPS bypass circuit is connected to a dedicated bypass supply. Where a single feed is used, the Input Mains and Bypass terminals are linked together on the UPS power connector blocks. The following diagram identifies the UPS input/output cabling requirements and provides information regarding the necessary fuse and cable ratings, and cable sizing. UPS Kohler PW 5000/TP Technical Specification Dated
14 Fuses & Cables Quick Reference SINGLE INPUT FEED (standard) Fuse A Mains (3x380/220V, 3x400/230V, 3x415/240V) DUAL INPUT FEED Fuse B Fuse C Cable A Cable B Cable C FA1 FA2 FA1 FA2 Rectifier Rectifier FA4 Inverter FA4 Inverter FA3 (F1) Static Switch FA3 (F1) Static Switch EXTERNAL BATTERY CABINET (option) Int. Batts. Output Switch IA2 Maint. Bypass IA1 EXTERNAL BATTERY CABINET (option) Int. Batts. Output Switch IA2 Maint. Bypass IA1 Load Cable D Load Cable D Single input feed Power (kva) Fuse A (Agl/CB) (A) Cable A (mm²) Cable D (mm²) 10 3 x 20 5 x x x 32 5 x x x 40 5 x x x 40 5 x x x 63 5 x 10 5 x x 80 5 x 25 5 x x 80 5 x 25 5 x 25 Dual input feed Power (kva) Notes: Fuse B (Agl/CB)(A) Cable B (mm²) Fuse C (Agl/CB)(A) Cable C (mm²) 1. Fuse and Cable recommendations to IEC :2001, or locally recognised standard. 2. The fuse and cable rating details in the above tables are a recommendation only. 3. The UPS must be installed to prescribed IEC or local regulations. 4. External DC Cables and Battery fuses are bespoke to the installation. Cable D (mm²) 10 3 x 20 5 x x 20 5 x x x 32 5 x x 32 5 x x x 40 5 x x 40 5 x x x 40 5 x x 40 5 x x x 63 5 x 10 3 x 63 5 x 10 5 x x 80 5 x 25 3 x 80 5 x 25 5 x x 80 5 x 25 3 x 80 5 x 25 5 x UPS Kohler PW 5000/TP Technical Specification Dated
Technical Specification
Technical Specification PowerWAVE 9000 10 250 kva (8-200 kw) per abinet Three phase input and output Single / Triple / Upgrade cabinets with Safe-Swap Modules (SSM) For premium power protection availability
PowerWAVE 6000 500kVA Model Technical Specification
PowerWAVE 6000 500kVA Model Technical Specification Pioneering solutions for total power protection Continuous power availability is essential in today s dynamic IT and process-related environments. It
DPA UPScale RI (Rack-Independent) Technical Specifications
DPA UPScale RI (Rack-Independent) Technical Specifications DPA UPSCALE TM highlights at a glance DPA UPScale with Safe-Swap Modules (SSM) For premium power protection availability Low total Cost of Ownership
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE
Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication
PowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
RIELLO ELETTRONICA. Master HP
RIELLO ELETTRONICA Master HP LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCS ELECTRO- MEDICAL DEVICES
User Manual PowerWAVE 8000DPA RI
User Manual PowerWAVE 8000DPA RI Pioneering solutions for total power protection UPS338-01-00 PowerWAVE 8000-RI DPA User Manual Dated 5 April 2013 Document Control ISSUE DATE REVISION SUMMARY 338-02-00
DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.
Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier
LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase.
LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro online UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase LOCAL AREA NETWORKS (LAN) INTERNET CENTERS (ISP/ASP/POP) ELECTRO-MEDICAL
Galleon 6-10K Online UPS. Voltronic Power Technology Corporation
Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection
Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0
The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,
4.0 UPS dedicated to ICT for unmatched energy savings
4.0 UPS dedicated to ICT for unmatched energy savings Introducing UPSaver by Borri, a new modular UPS series for the ICT industry, totally configurable, quickly scalable, with high efficiency and low TCO.
Online UPS. PowerWalker VFI 1000R/1U
Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.
LAP ENERGIA PARA DATACENTERS
LAP ENERGIA PARA DATACENTERS Latin American Power. CABA, Argentina. 2 UPS INDOOR Latin American Power. CABA, Argentina. ALI ELITE SERIES Line Interactive UPS Tower/19 Rack Mount Versions 19 Rack Mount
PowerValue TM. Compact protection for power supply For Continous Power Protection Availability
PowerValue TM Compact protection for power supply For Continous Power Protection Availability PowerValue TM The Beauty of Power Protection Simplicity PowerValue TM represents an accurately balanced combination
Galaxy VM. Three-phase power protection. schneider-electric.com
Galaxy VM Three-phase power protection schneider-electric.com 2 schneider-electric.com schneider-electric.com 3 Galaxy VM trusted partner for your business continuity Features and benefits Highly efficient,
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA -3000VA Intelligent, Reliable UPS Protection Liebert
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply
APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality
on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications
ZP110 on-line UPS 1, 2, 3, 6, 10kVA single/single phase LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs Emergency Devices (Lights/Alarms) Electro-Medical Devices
UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES INDEX General characteristics page 4 Modular page 12 Conventional page 32 Line-interactive page 44 Communication
User Manual 1K/2K/3K Online UPS
User Manual 1K/2K/3K Online UPS Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4. Operation...
GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work
GE Consumer & Industrial Power Protection UPS Uninterruptible Power Supplies GE imagination at work For more than a century, GE has led the way with innovative technologies and groundbreaking quality initiatives
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
Liebert APM from 30-150 kw. The Compact Row-Based UPS With FlexPower Technology TM
Liebert APM from 30-150 kw The Compact Row-Based UPS With FlexPower Technology TM Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative
Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw
Tender Technical Specification For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw 1 di 14 Index 1 GENERAL REQUIREMENTS... 4 1.1 SUBJECT AND AGREEMENT TYPE... 4 1.2 CONDITIONS... 4 2 GENERALI
The UPS for the highest security in industry and data centres
The UPS for the highest security in industry and data centres P R E M I U M 6,000-20,000VA T E C H N O L O G Y www.online-usv.de Perfect: The ultimate protection against blackout and data loss The new
GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work
GE Consumer & Industrial Power Protection Digital Energy LP Series UPS Uninterruptible Power Supply 3-30 kva GE imagination at work For more than a century, GE has led the way with innovative technologies
MGE Galaxy 7000. 160/200/250/300/400/500 kva Power efficiency for business continuity
MGE Galaxy 7000 160/200/250/300/400/500 kva Power efficiency for business continuity Performance three-phase power protection with high adaptability to meet the unique requirements of medium to large data
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
MAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
USER MANUAL Online UPS 1K/2K/3K
USER MANUAL EN Online UPS 1K/2K/3K Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1.1. Transportation 2 1.2. Preparation 2 1.3. Installation 2 1.4. Operation 2 1.5.
GE Digital Energy. TLE Series UPS. 160-400 kw three phase 400 Vac. with best-in-class efficiency. gimagination at work
GE Digital Energy TLE Series UPS 160-400 kw three phase 400 Vac with best-in-class efficiency gimagination at work GE provides clean, efficient and reliable power for today s digital world with the ultra
TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS
Capacity Technology Inverter Technology Noise Level Operating Temperature Humidity Harmonic Distortion Total DC bus voltage Battery recharge time (After Complete discharge) to 100% charge Crest Factor
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
USER MANUAL Online UPS 1K/2K/3K Rack
USER MANUAL EN Online UPS 1K/2K/3K Rack Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation 2
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,
City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION
City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION This Appendix A includes technical documents and specifications for the Toshiba 4200 FA 30 kva Uninterruptable Power
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
Specification Requirements DBL 700MX and 1000MX Series UPS
Specification Requirements DBL 700MX and 1000MX Series UPS Theory of Operation Upon loss of utility power, the UPS inverter shall continue to provide seamless pure sine-wave AC from the batteries without
UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES
UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES 9900A The 9900A UPS system uses the most advanced IGBT in both the converter and inverter with Digital Signal Processor (DSP)
EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.
ENGLISH EATS6 EATS6N Installation and user manual Copyright 05 EATON All rights reserved. Service and suppt: Call your local service representative SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. This manual
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency
GE Critical Power TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency imagination at work GE provides clean, efficient and reliable power for today s digital world with the
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
VISION UPS UPS PRODUCT CATALOGUE
VISION UPS UPS PRODUCT CATALOGUE 2012 1 VISION UPS Systems S. à r. l. About VISION UPS VISION UPS SYSTEMS S. à r. l. was established in 2003 by the two belgian UPS-specialists Patrick Willems and Ralph
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Eaton 93PM UPS Where aesthetics meet intelligence.
Brochure 100 kw Eaton 93PM UPS Where aesthetics meet intelligence. 93PM features and benefits The Eaton 93PM UPS combines unprecedented and reliability with eye-catching design. A space-saving, flexible
ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw
Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview
Overview The Tower UPS "G2" models are the next generation HP tower UPSs with USB support. These new UPSs are designed to provide advanced power protection (or increased uptime and data corruption avoidance)
APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply
APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of
TLE Series. Product Description. 160-200-320-400 kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES
TLE Series Product Description 160-200-320-400 kva / 400Vac / S1 KEY BEEFIT High efficiency up to 96.5% in on-line double conversion and 99% in eboost operation mode Unity output power factor; full power
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva
Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva 1. UPS definition... 2 1.1. Purpose... 2 1.2. Brief description... 2 2. Operating principles... 2 2.1. Normal operation...
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V
Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8
Door Mount UPS (Patent Pending) Shelf Mount UPS (Patent Pending) DESCRIPTION: The Always On NDM (door mount) and NSM (shelf mount) Series UPS s are dual conversion online UPS systems provided in slim,
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Product catalog ABB UPS products and solutions Power protection for critical infrastructures
Product catalog ABB UPS products and solutions Power protection for critical infrastructures Welcome to ABB s Power Protection catalog The number of critical applications that simply cannot be allowed
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
Specification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA
the Mega Power protection up to 5.4 MVA range is capable of a maximum system size of up to 5.4 MVA and specifically designed for demanding Data centre applications such as large DTC of banks / insurances,
Chloride 80-NET from 60 to 500 kw. Secure Power for Mission Critical Applications
Chloride 80-NET from 60 to 500 kw Secure Power for Mission Critical Applications Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL
OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-NMS Rev. X1 E-Mail: [email protected] www.olsontech.com
Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M
Power Protection for Business Critical Continuity Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications Compact Three-phase UPS with Optimum Load Performance And
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
SG Series UPS 10-600 kva three phase 400 Vac
GE Critical Power SG Series UPS 10-600 kva three phase 400 Vac with ultra-high efficiency eboost TM technology imagination at work From protecting assets such as generators, transmission lines and motors,
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
USER MANUAL Online UPS 6K/10K RACK
USER MANUAL EN Online UPS 6K/10K RACK Uninterruptible Power Supply System Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully
10000HXL31/15000HXL31/20000HXL31
Table of Contents www.eaton.com/dxups USER MANUAL ON LINE UPS 10000HXL31/15000HXL31/20000HXL31 Uninterruptible Power Supply Table of Contents 1. Brief introduction 1.1 System and model description---------------------------------------------------------------------1
TOSHIBA G9000 80/100/160/225 kva
CORPORATE OFFICE 13131 WEST LITTLE YORK ROAD HOUSTON, TX 77041 PHONE: (713) 466-0277 (800) 231-1412 FACSIMILE: (713) 896-5226 TOSHIBA G9000 80/100/160/225 kva GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
Cisco Nexus 7000 Series Power Supply Modules
Cisco Nexus 7000 Series Power Supply Modules Product Overview The Cisco Nexus 7000 Series Power Supply Modules (Figures 1 and 2) deliver fault tolerance, high efficiency, load sharing, and hot-swappable
UNINTERRUPTIBLE POWER SUPPLY (UPS)
Your Inspirations. Our Innovations. UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting Your Data CATALOGUE Revision 0 Table of Contents Table of Contents About Us - Company Profile Online UPS Professional
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
Liebert NXC from 10 to 200 kva
Liebert NXC from 10 to 200 kva Emerson Network Power, a division of Emerson, is a global company that provides a unique combination of industry expertise, technology, and resources to make the future of
NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL
NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL [email protected] / www.tuncmatik.com Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3.
O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications
Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection
Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
3500/22M Transient Data Interface
3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery
Product brochure Eaton 93PS UPS 8-40 kw. More advanced. power. protection
Product brochure Eaton 93PS UPS 8-40 kw More advanced power protection Eaton 93PS UPS 8-40 kw Lowest total cost of ownership and maximum availability taking scalability, resiliency, safety and efficiency
650W Single Output Power Supply
AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent