BB800 Off-Grid Solar System
|
|
- Annabelle Griffin
- 8 years ago
- Views:
Transcription
1 BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry level and affordable off-grid solar home system is capable of powering a wide range of AC electrical appliances in a typical small suburban home Detailed Product Specifications Inverter: Continuous Output Power: 2KW, Maximum Surge Output Power: 3000W, Pure Sine Wave 230V 50Hz Output, 94% Maximum Efficiency. Thermal, Overload, Short-circuit and Earth-fault Protection. Computer Interface. Solar Charge Controller and Connection Box: 63A Rating with PWM functionality. DC reverse polarity, low voltage and overcurrent protection. Integrated AC and DC fuses. DC outputs for low power lighting systems. AC Input-Output: Connection to grid electricity supply and household wiring system. Battery: 4 x 200Ah 12V Batteries in series with battery casing, fusing and wiring. Solar Panels: 4 x 250W Polycrystalline Solar Panels with mounting and wiring. 1
2 BBOXX Solar Control Unit KEY PRODUCT FEATURES 1.5kW (24V) Solar Charge Controller Easy to Install Design Integrated AC and DC Fusing /ŶƚĞŐƌĂƟŽŶǁ ŝƚśdžƚğƌŷăů/ŷǀ ĞƌƚĞƌ ŽŶŶĞĐƟŽŶƚŽ' ƌŝě K ƵƚƉƵƚƐ ĂƩ ĞƌLJs ŽůƚĂŐĞ ŝɛɖůălj 24V DC Protected Outputs K ƵƌĞĂƐLJƚŽŝŶƐƚĂůůƐŽůĂƌĐŚĂƌŐĞĐŽŶƚƌŽůůĞƌĂŶĚĐŽŶŶĞĐƟŽŶďŽdžŵĂŬĞƐůĂƌŐĞƌŽŶ-grid and off-grid ƐŽůĂƌŝŶƐƚĂůůĂƟŽŶƐĞĂƐLJƚŽƐĞƚ-up and monitor. ĞƚĂŝůĞĚWƌŽĚƵĐƚ^ƉĞĐŝĮ ĐĂƟŽŶ Solar Charge Controller: Wt D ŚĂƌŐĞŽŶƚƌŽůůĞƌ ϲϱŵădžđƶƌƌğŷƚ Ϯϰs ĂƩ ĞƌLJs ŽůƚĂŐĞ WĞĂŬϵϰй ĸ ĐŝĞŶĐLJ ŽŶŶĞĐƟŽŶƐ: External Inverter (24VDC, 3kW Peak Power Output) K yyăʃ ĞƌLJĂƐŝŶŐ;Ϯϰs ' D ^ĞĂůĞĚ>ĞĂĚĐŝĚĂƩ ĞƌLJĂŶŬ ϮϰK ƵƚƉƵƚƐ;>ŝŐŚƚƐ &ĂŶƐĞƚĐD ĂdžWŽǁ ĞƌK ƵƚƉƵƚϰϴϬt K ǀ ĞƌůŽĂĚĂŶĚ^ŚŽƌƚŝƌĐƵŝƚWƌŽƚĞĐƟŽŶ ^ŽůĂƌWĂŶĞůŽŶŶĞĐƟŽŶƐ AC - Grid IN/OUT and External Inverter IN/OUT Display: ĂƩ ĞƌLJs ŽůƚĂŐĞŝƐƉůĂLJ ŚĂƌŐŝŶŐ/ŶĚŝĐĂƚŽƌ Ϯϰs K ƵƚƉƵƚK E K &&/ŶĚŝĐĂƚŽƌ Fusing: 24V,125A DC Fuse, 220V, 20A AC Circuit Breakers (Input and Output) Weight: (10kg Package Weight) Dimensions: (Control Box: 330mm x 470mm x 90mm) 1
3 ŽŶŶĞĐƟŽŶ ŝăőƌăŵ (BB400/800/1200) AC Grid or Generator Input AC Outputs BBOXX Inverter/Charger Solar Panels 24V DC Outputs K yy Ϯϰs ϮϬϬ Ś ĂƩ ĞƌLJ ĂƐŝŶŐ 2
4 BBOXX 250W SOLAR MODULE DATASHEET MODULE DIAGRAM ELECRICAL SPECIFICATIONS Rated Power (W) 250 Maximum Power Voltage (V) 34.5 Maximum Current (A) 7.10 Open Circuit Voltage (V) 42.3 Short Circuit Current (A) 7.95 Cell Efficiency (%) Module Efficiency (%) 12.7 NOCT 45 C(+2 C) Output Tolerance (%) +/- 5% Fill Factor (%) 70% % Measured at Standard Test Conditions (STC) : Irradiance of 100W/m², air mass of 1.5, cell temperature of 25 C MECHANICAL SPECIFICATIONS Solar Cell Cell Size (mm) Module Size (mm) Frame (Type. Material, Tickness) 76 PCS 156x x992 x50 Anodized Alu. alloy frame,50 mm thickness TEMPERATURE COEFFICIENT Weight (Kg) 26.5 dljɖğk Ĩ:ƵŶĐƟŽŶŽdž (PV- BTBL0801 ) Cable Length 1.1m Connector Type PV-BTBL0601 Power : Pmax (%/ C) -0.5%/ C ĞůůŶĐĂƉƐƵůĂƟŽŶ EVA Voltage : Voc (%/ C) -0.34%/ C Current : Isc (%/ C) +0.05%/ C OPERATION CONDITION & SAFETY RATINGS WARRANTY & CERTIFICATIONS Warranty 20 years limited 70% power warranty Warranted Tolerance (+/-) +/- 5% ĞƌƟĮ ĐĂƟŽŶƐ IEC-61000(CE) ŵďŝğŷƚk ƉĞƌĂƟŶŐ Temperature IP Wind Bearing Hail Impact Rate -40 C to 85 C IP65 60m/s(200kg/m²) 227g steel ball dropped 1m height, equivalent to 25mmф hail at 97 km/h
5 BBOXX 2KW INVERTER DATASHEET MODULE DIAGRAM CHARGER MODE SPECIFICATIONS Input Wave Type Nominal Input Voltage Input Voltage Range Low Voltage shutoff Low Voltage Recovery Over voltage Shut off Over Voltage Recovery Nominal Input Frequency Output Wave Type Transfer Time (Ac to Dc) Transfer Time (Dc to Ac) WƵƌĞƐŝŶĞǁ Ăǀ Ğ;ƵƟůŝƚLJŽƌ generator) 220V/230V/240V AC 184V~AC253V 184VAC±4% 194VAC±4% 253VAC±4% 243VAC±4% 50Hz or 60Hz (auto detect) Same as the input wave type <4ms <4ms INVERTER MODE SPECIFICATIONS TECHNICAL SPECIFICATIONS K ƉĞƌĂƟŶŐdĞŵƉĞƌĂƚƵƌĞ Range 0 C to 60 C Storage temperature -15ºC~60ºC Humidity 5% to 95% Noise Max 60dB Cooling-Variable Speed Cooling &ĂŶƌƵŶƵŶĚĞƌǀ ĞŶƟůĂƟŽŶ ĐŽŶĚŝƟŽŶ Dimension(MM) 442*218*179 Packing Size(MM) 600*300*300 Net Weight(KG) 27 Gross Weight(KG) 29 WARRANTY & CERTIFICATIONS Warranty (under terms and condi- ƟŽŶƐ ĞƌƟĮ ĐĂƟŽŶƐ 2 Years CE Conformity, Conform to EU EMC ŝƌğđɵǀ ĞϮϬϬϰ ϭϭθ E 55022:2010,EN :2006+A1:2009+A2:2009, EN : 2008, EN :2006+A11:2009+A12:2011, EN 55024:2010 Power Factor Nominal Output Frequency (Hz) Output Voltage Range 1 (Sufficient output power) 50Hz ± 0.3Hz or 60Hz ±0.3Hz ±10% RMS Efficiency 87%~98% Over->ŽĂĚWƌŽƚĞĐƟŽŶ >Žǁ ĂƩ ĞƌLJůĂƌŵ Low DC input voltage ĂƵƚŽŵĂƟĐƐŚƵƚ-down High DC input voltage warning & outage High DC input voltage Recover Power-saving mode Power on mode Safety ŽŵŵƵŶŝĐĂƟŽŶƉŽƌƚ (110%<load<125%) ±10%: Fault ;ƐŚƵƚĚŽǁ ŶŽƵƚƉƵƚĂŌĞƌϭϱ minutes; (125%<load<150%) ±10%: Fault ;ƐŚƵƚĚŽǁ ŶŽƵƚƉƵƚĂŌĞƌϭϬƐ Load>150% ±10%: Fault ;ƐŚƵƚĚŽǁ ŶŽƵƚƉƵƚĂŌĞƌϮϬƐ 21.0Vdc ± 0.6Vdc (24V Input) 20.0vdc± 0.6Vdc (24V Input) 32Vdc ± 0.6Vdc (24V Input) 31.0Vdc ± 0.6Vdc (24V Input) 1W~6W 20W~60W CE(EN ), EMC:EN ,C2 RS232,RS485
6 CHARGE SPECIFICATIONS Input voltage Input voltage range Output voltage Charge current ŚĂƌŐĞĐƵƌƌĞŶƚĐŽƌƌĞĐƟŽŶ /ŶŝƟĂůŚĂƌŐĞs ŽůƚĂŐĞ Charger short-đŝƌđƶŝƚɖƌžƚğđɵžŷ Circuit breaker K ǀ ĞƌůŽĂĚƉƌŽƚĞĐƟŽŶ Charging Method ĞƐĐƌŝƉƟŽŶK ĨŚĂƌŐŝŶŐ^ƚĂŐĞƐ 220Vac/230Vac 196~255Vac ĞƉĞŶĚŽŶƚŚĞďĂƩ ĞƌƚLJƉĞ 35A ±5A 9.0~15.7V/31.4V/62.8V Circuit Breaker 20A t ŚĞŶƚŚĞďĂƩ ĞƌLJǀ ŽůƚĂŐĞхϯ ϭ ϰs ĚĐ Ğǀ ĞƌLJƐĞĐŽŶĚƐŽƵŶĚƐϬ ϱɛğđžŷě ŝƚďƌğăŭɛěžǁ ŶĂŌĞƌ 60 seconds. Constant current charging( Constant current stage) constant voltage charging (constant voltage stage) float charging (constant voltage stage) Constant current charging Phase: When connected AC input, the charger will works ǁ ŝƚśŵădžŝŵƶŵđžŷɛƚăŷƚđƶƌƌğŷƚƶŷɵůđžŷɛƚăŷƚǀ ŽůƚĂŐĞƐƚĂŐĞ ^ŽŌǁ ĂƌĞƟŵĞƌĐĂůĐƵůĂƚĞƐĨƌŽŵƚŚĞďĞŐŝŶŶŝŶŐŽĨƉŽǁ Ğƌ ƟůůŝƚƌĞĂĐŚĞĚƚŚĞĐŽŶƐƚĂŶƚǀ ŽůƚͲ ĂŐĞϬ ϯs ĂŶĚƚŚĞŶŵĂƌŬƚŚĞƟŵŝŶŐĂƐd 0, T 0 10 = T 1. Constant voltage charging Phase: ^ƚăƌɵŷőĩƌžŵd 1, charger will keep constant voltage ŵžěğƶŷɵůƚśğɵŵğƌį ŶŝƐŚĞĚ ŶĚƚŚĞŶƐůŽǁ ƚžňžăƚǀ ŽůƚĂŐĞ dśğŵŝŷŝŵƶŵůŝŵŝƚğěžĩ ƟŵĞƌŝƐϭŚŽƵƌ ƚśğŵădžŝŵƶŵŝɛϭϯśžƶƌɛ Float charge phase: ƵƌŝŶŐƚŚĞŇŽĂƚĐŚĂƌŐŝŶŐƉŚĂƐĞ ƚśğǀ ŽůƚĂŐĞǁ ŝůůŭğğɖăɛňžăɵŷő voltage. /ĨƚŚĞŚĂƌŐĞƌŬĞĞƉŝŶƚŚĞŇŽĂƚĐŚĂƌŐŝŶŐƐƚĂŐĞĨŽƌϭϬĚĂLJƐ ƚśğđŝƌđƶůăɵžŷƌğɛƚăƌƚɛƚž ĐŚĂƌŐĞƚŚĞďĂƩ ĞƌŝĞƐ CHARGING CURVE
7 BBOXX 200AH BATTERY DATASHEET DIMENSIONS TECHNICAL SPECIFICATIONS Nominal Voltage Nominal Capacity Specific Energy Dimensions (LxWxH, mm) Weight Standard Terminal 12V 200Ah (20h rate) 39.3 Wh/kg 522x240x240 61kg Type F16 CAPACITY SPECIFICATIONS Cut-Off Voltage 20h rate 10.0A 200.0Ah CHARACTERISTIC DISCHARGE CURVES C 10h rate 18.4A 184Ah 1.75V/cell 5h rate 32A 160Ah 1.67V/cell 1h rate 120A 120Ah 1.67V/cell 15min rate 352A 88Ah CHARGING SPECIFICATIONS OPERATION CONDITIONS ZĞĐŽŵŵĞŶĚĞĚK ƉĞƌĂƟŶŐ Temperature ŝɛđśăƌőŝŷők ƉĞƌĂƟŶŐ Temp. Range Recommended Storage Temperature 25 C -10 to 50 C 25 C Charge Voltage (constant) Internal Resistance ;ĨƵůůLJĐŚĂƌŐĞĚďĂƩ ĞƌLJ Discharge Current (5s max) Float 13.5 ~ 13.8V Cycle 14.4 ~ 15.0V < 8mΩ 330A Max. Charge Current 9.9A Approx. Final Charge Current (2.25V/cell float) Approx. Final Charge Current (2.45V/cell float) 60mA 330mA Self-Discharge 6 25 C ACTUAL WATTAGE CAPACITY AT VARIOUS DISCHARGES C) Cut-off voltage 5 min 10 min 15 min 30 min 45 min 60 min 9.6 V W W 792.0W 455.4W 335.9W 257.4W 9.9 V W W 776.2W 450.8W W 10.2 V W 986.0W 759.0W 444.8W 327.9W 251.5W 10.5 V W 951.7W 735.9W 434.9W 321.4W 247.4W 10.8 V W 878.5W 703.6W 419.1W 305.3W 240.2W
8 WARRANTY & CERTIFICATIONS t ĂƌƌĂŶƚLJ;ƵŶĚĞƌƚĞƌŵƐĂŶĚĐŽŶĚŝƟŽŶƐ 2 Years Warranted Tolerance 70% ĞƌƟĮ ĐĂƟŽŶƐ CE Conformity, Conform to EU EMC ŝƌğđɵǀ ĞϮϬϬϰ ϭϭθ E ϲϭϭϭϭ-6-1: 2007, EN : 2007, IEC, JIS, UL, BS Part 4 IEC /'04 and JIS C Warning! Precautions to take against self discharge: - The batteries should be stored in a cool, dry place. - The batteries should not be stored in direct sunlight. - The batteries should not be subjected to an external heat source. - The voltage of batteries in stock should be regularly checked. - If stored at more than 30 C, the battery sould be recharged at least once every 3 months - The lifespan of BBOXX SLA batteries or solar kits containing SLA batteries will be guaranteed according to BBOXX SLA batteries lifespan vs discharge curves found in the technical folder on the BBOXX website. - The consignee must ensure during a warranty claim that the customer did not overload the batteries, connect loads directly to the battery terminals or modified the low voltage disconnect points of BBOXX s discharge controllers or inverter-chargers. - The consignee must make sure that the system is installed and used according to BBOXX user manuals.
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
More informationUser Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1
User Manual Hybrid 1KW-5KW INVERTER / CHARGER Version: 1.1 Table of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Product Overview... 3 INSTALLATION...
More informationEGSTON Standard E2xFxWx 12W
General description The family of switchmode power supplies offers an unmatched degree of flexibility and performance fulfilling even the most stringent requirements. Highly flexible electrical configuration
More informationYSmart Technology Co.,Ltd
YSmart Technology Co.,Ltd GWV Series Grid Tie Microinverter User Manual The copyright of this user manual belong to YSmart TechnologyCompany Limited. Without the written permission of the copyright holder,
More informationPhotovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
More informationPHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More informationTECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS
Capacity Technology Inverter Technology Noise Level Operating Temperature Humidity Harmonic Distortion Total DC bus voltage Battery recharge time (After Complete discharge) to 100% charge Crest Factor
More informationMAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
More informationOperating Manual UWAPS-TINY Series
Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationEmergency lighting units EM powerled
M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year
More information2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams 3000. Sunteams 4000 Sunteams 5000
Photovoltaic Inverter Specification Version 2.06 1500 2000 3000 4000 5000 Kinglong New Energy Technology Co.Ltd. Kinglong New Energy Technology Co.Ltd. specification 1.1. Introduction... 3 1.1.1. Environment...
More informationPhotovoltaic System Overcurrent Protection
Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and
More informationTruPower-Portable-500W. Solar Starter kit
TruPower-Portable-500W Solar Starter kit This Solar starter kit is an easy to use solar power supply system that is the complete solution for all your solar power needs. It is a solar generator that converts
More informationANTENERGY. Powered By BOSCH Cells Portable Solar Panel Kit. User Manual and Product Specifications
ANTENERGY Powered By BOSCH Cells Portable Solar Panel Kit User Manual and Product Specifications IMPORTANT Read instructions before operation. 1 / 12 Index Getting to know your Portable Solar Panel Kit
More information650W Single Output Power Supply
AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent
More informationREGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
More informationO WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications
Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection
More informationSpecification Requirements DBL 700MX and 1000MX Series UPS
Specification Requirements DBL 700MX and 1000MX Series UPS Theory of Operation Upon loss of utility power, the UPS inverter shall continue to provide seamless pure sine-wave AC from the batteries without
More informationGalleon 6-10K Online UPS. Voltronic Power Technology Corporation
Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection
More informationSmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
More informationST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
More informationHome Solar Kit 1800. Owner s Manual. Model: HS 1800-60
Home Solar Kit 1800 Owner s Manual Model: HS 1800-60 1. INTRODUCTION Thank you for purchasing the KISAE Home Solar Kit. With our state of the art, easy to use design, this product will offer you reliable
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationYour Sharp system will be supplied with one of the following sets of panels:
Sharp3000 3kW Solar System Panel Specifications Your Sharp system will be supplied with one of the following sets of panels: Manufacturer Mono Or Poly Size (Watts) Panels Required To Achieve Minimum 3000
More informationYour own power station: For continuous power
Mass Combi Ultra Your own power station: For continuous power Compact and lightweight inverter/battery charger Seamless switching between generator and grid Separate second charger Integrated MPPT solar
More informationAC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models
TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual
More informationUser Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.
DONGGUAN SHENGYANG INDUSTRIAL CO., LTD SY WMVC Smart Grid Tie Microinverter User Manual Dongguan Shengyang Industrial Co., Ltd. ADD: No. 1 Shangxin Road, New Village, Xin An Community, Chang An Town, Dongguan
More information1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
More informationADDENDUM #1(BID PACKAGE # 3)
H2Engineering, Inc. 114 East Fifth Avenue Tallahassee, FL 32303 Phone 850.224.7922 Fax 850.224.5876 ADDENDUM #1(BID PACKAGE # 3) To: Jeff Williams From: Peter Lindstrom Co: Leon County Date: October 04,
More informationActuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationSmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
More informationIndustrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P
Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources
More informationA reasonable, new furnace (mid efficiency) has the following electrical requirements:
June 2007 Power Backup Systems for Your Home. As promised from a previous safety meeting, a couple of options to protect you home in the event of a power failure. These options are for the most serious,
More informationAPPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors
APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN -
More information30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
More informationAPC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
More informationPWM-90 series IP67 TRC ELECTRONICS, INC. 1.888.612.9514. www.trcelectronics.com/meanwell. Mean Well PWM-90 Series
TRC ELECTRONICS, INC. 90W PWM output LED power LED supply Power Supply Constant Voltage PFC High Efficiency 90W Ⅱ Ⅱ IP67 TRC ELECTRONICS, INC. 90W PWM output LED power supply SPECIFICATION MODEL OUTPUT
More information650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
More informationPB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB-600-12 PB-600-24 PB-600-48 14.4V 28.8V 57.6V 13.8V
.. 600W Single Output Charger PB600 series SPECIFICATION MODEL OUTPUT INPUT PROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note 2) OTHERS NOTE BOOST CHARGE VOLTAGE FLOAT CHARGE VOLTAGE RECOMMENDED BATTERY
More information12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
More informationEPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!
EPSOLAR LS0512R / LS0524R Solar Light Controller INSTRUCTION MANUAL Please read this manual carefully before using the product! LandStar LS0512R / LS0524R Solar Light Controller Nominal system voltage
More informationWINGLIKE ELECTRONICS CO.,LTD
WINGLIKE ELECTRONICS CO.,LTD SPECIFICATION FOR APPROVAL AC/DC ADAPTOR CUSTOMER: CUSTOMER SPECS INPUT: 100-240V AC 50-60HZ, 5V/2A ADAPTOR OUR MODEL NO.: GM-050200 (UL) E321192 SPECIFICATION NO.: WL1105102
More informationSmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationDS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
More informationEnergy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
More informationInverter / Charger Installation General Operations and AC and DC Connections
Inverter / Charger Installation General Operations and AC and DC Connections The Inverter is just one piece. Sometimes, a tendency is to mount the inverter and batteries, and make it work It is better
More informationHow To Control A Battery Cell Phone With A Battery Power Control System
Wind/Solar Hybrid Street Light Controller User Manual Model: HY-WSC04-12AWM, HY-WSC04-12/24AWM, HY-WSC06-24AWM, HY-WSC06-48AWM 1. Product Introduction The wind/solar hybrid street light controller is an
More informationBack-UPS 650 VA 120 V with AVR (BX650CI-LM)
Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit
More informationMatch. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationTHERMAL CHARACTERISTICS Nominal operating cell temperature(noct) [ C] 48,2±2 48 Temperature coefficient P MPP [%K] -0,41-0,47 Temperature coefficient I SC [%K] 0,05 0,04 Temperature coefficient U OC [%K]
More informationGROWATT NEW ENERGY CO.,LTD. service@ginverter.com GR - UM - 001-07
GROWATT NEW ENERGY CO.,LTD service@ginverter.com GR - UM - 00-07 Content Congratulations on choosing our Grid PV Inverter, Our Grid PV Inverter are a highly reliable products due to their innovative design
More informationSOLAR MODULES SOLARFLEX Polska Grupa Inwestycje Ekologiczne Sp. z o.o. PRODUCTS LINE of SOLARFLEX Price list
SOLAR MODULES SOLARFLEX Polska Grupa Inwestycje Ekologiczne Sp. z o.o. PRODUCTS LINE of SOLARFLEX Price list Nr Indeks Type of modules Set components Peak Power [Pmax] Net price 1 SOLARFLEX 36W Flex flexible
More informationDC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.
Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier
More informationPhoenix Multi 120Vac 12/1600/70 12/2500/120 24/1600/40 24/3000/70. Phoenix MultiPlus 120Vac 12/2500/120 24/3000/70
INSTALLATION MANUAL Phoenix Multi 120Vac 12/1600/70 12/2500/120 24/1600/40 24/3000/70 Phoenix MultiPlus 120Vac 12/2500/120 24/3000/70 Phoenix Inverter 120Vac 12/1600 12/2500 24/1600 24/3000 1 Copyrights
More informationSmart-UPS APC Smart-UPS 1000VA USB & Serial 230V
Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V APC Smart-UPS, 670 Watts / 1000 VA,Input 230V / Output 230V, Interface Port DB-9 RS-232, SmartSlot, USB Includes: CD with software, Smart UPS signalling
More informationUninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
More informationUser s Manual AURORA 1.2K/2.2K
User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable
More informationSeries AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationManual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationChrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
More informationPWM-60 series IP67 TRC ELECTRONICS, INC. 1.888.612.9514. www.trcelectronics.com/meanwell
60W PWM output LED power supply Ⅱ IP67 Ⅱ TRC ELECTRONICS, 60W PWM output INC. LED power supply SPECIFICATION MODEL OUTPUT INPUT PROTECTION DC VOLTAGE RATED CURRENT RATED POWER DIMMING RANGE PWM FREQUENCY
More informationProblem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is
More informationLTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
More informationDCS Series 1 kw, 1.2 kw, & 3 kw
DCS Series 1 kw, 1.2 kw, & 3 kw AVAILABLE WITH LXI STANDARD COMPLIANT ETHERNET Applications Automotive Electronics Rackmount ATE System Battery Charging DCS Series DCS Series: 1 kw, 1.2 kw, & 3 kw DCS
More informationWorld Trade Company B.V.
WS56 LED solar/wind straatverlichting De WS56 straatverlichting is een energiebesparende straatverlichting voorzien van twee zonnepanelen en een windmolen om de High Power LED unit (type WU2) te voeden.
More informationSolar Controller / Battery Charger User s Manual
Solar Controller / Battery Charger User s Manual 1 Congratulations! You have made an excellent choice by purchasing this high quality KORR PWM solar controller which has been manufactured to the highest
More informationSOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings
*** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not
More informationStroom voor elke toepassing
ELECTRICITY: ALWAYS & EVERYWHERE With VICTRON Phoenix MultiPlus and a HONDA Generator An intelligent combination with endless possibilities! Electrical appliances that increase on board comfort, such as
More informationSingle Output Switching Power Supply
.. RS- Code: CLP-A Single Output Switching Power Supply SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY EMC (Note 6) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE
More informationDRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More information7.5 Watt AC-DC Switch Power Supply
MAIN FEATURES: 7.5W Small Compact Size PCB Mount Single Output Regulated Output Range : 3.3VDC 24VDC Input Range : 85VAC 265VAC/47 63Hz Or 120VDC 370VDC Very Low Standby Power Consumption < 0.15W Better
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationApplication Note: String sizing Conext CL Series
: String sizing Conext CL Series 965-0066-01-01 Rev A DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND ARC FLASH This Application Note is in addition to, and incorporates by reference, the installation
More informationLS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
More informationChrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
More informationTechnical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0
The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,
More informationDC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationAssembled in Florida, USA.
*some models Assembled in Florida, USA. Check our online UPS section at: www.olinsys.com/ups Descubra nuestra sección online de UPS en: www.olinsys.com/ups UPS Uninterruptible Power Supply / Alimentación
More information4KVA/5KVA Parallel Installation Guide
4KVA/5KVA Parallel Installation Guide 1. Introduction This inverter can be used in parallel with two different operation modes. 1. Parallel operation in single phase with up to 4 units. The supported maximum
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationHome Solar Kit 1800. Owner s Manual. Model: HS 1800-60
Home Solar Kit 1800 Owner s Manual Model: HS 1800-60 For safe and optimum performance, the Home Solar Kit must be used properly. Carefully read and follow all instructions and guidelines in this manual
More informationSolarMax P series The power package for residential solar plants
SolarMax P series The power package for residential solar plants The future-proof solution The requirements for residential photovoltaic plants have increased continuously in the past years. Due to our
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationDigital Ground Resistance Tester. Models 4620 & 4630. Digital Ground Resistance Tester
Digital Ground Resistance Tester Models 4620 & 4630 Digital Ground Resistance Tester Models 4620 and 4630 perform both ground resistance and soil resistivity tests. These testers measure from 0 to 2000Ω,
More informationSTRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
More informationSmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMX750SLT Highlights 750VA line interactive tower UPS; Sine wave output 220/230/240V nominal
More informationSmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial
SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1000RT2U Highlights 1kVA / 1000VA / 900W line-interactive 2U rack/tower UPS, Sine
More informationISO 9001 : 2000 certified Copyright 2008 All rights are reserved
LED STREET FLOOD LIIGHT Teksav Teknoloji Elektrik Elektronik Makine Sanayi ve Tic A.S. 10016 Sokak No: 20 A.O.S.B. Cigli Izmir Turkey Tel : +90-232- 328 1141 (PBX) Fax : +90-232- 328 1147 Doc no : 081027-1
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationHandheld portable appliance testers
PAT100 SERIES Handheld portable appliance testers PAT100 SERIES Handheld portable appliance testers Simple Tick/Cross, pass/fail indication plus measurement Battery powered with rechargeable options Includes
More informationvictron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850
victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850 SECTIONS ENGLISH 1 NEDERLANDS 27 DEUTSCH 55 This page intentionally left blank. ENGLISH USER MANUAL Victron Atlas
More information