Tough Decision: On-Line or Line-Interactive UPS?
|
|
|
- Daisy Atkins
- 10 years ago
- Views:
Transcription
1 W H I T E P A P E R Tough Decision: On-Line or Line-Interactive UPS? How to Choose the Right Protection for Your Network Executive Summary In today s data-driven, technology-dependent world, no organization large or small can afford the financial cost, customer frustration and business disruption caused by network downtime. That means complete protection against all potential power problems, including blackouts, brownouts, surges and line noise, is a must. The good news is there are plenty of options for protecting your network. But with so many different types of uninterruptible power supply (UPS) systems available, the challenge is selecting the one that best matches your needs and budget. For 120 V equipment loads up to 3,000 VA, on-line, double-conversion UPS systems and network-grade line-interactive UPS systems both offer high-performance protection. This document provides an in-depth comparison to help you determine which UPS type is the better choice for your application. 1. Tough Decision: On-Line or Line-Interactive UPS?
2 Table of Contents How Much Protection is Enough?...3 What You Should Know about On-Line, Double-Conversion UPS Systems...4 How They Work...4 The Biggest Benefits...5 Things to Think About...6 What You Should Know about Network-Grade Line-Interactive UPS Systems...7 How They Work...7 The Biggest Benefits...8 Things to Think About...9 What Do the Similarities and Differences Mean for Your Application?...10 Sample UPS System Comparison...11 The Tipping Point...12 About Tripp Lite Tough Decision: On-Line or Line-Interactive UPS?
3 How Much Protection is Enough? IT is the lifeblood of virtually any business in today s highly connected, data-centric environment. Whether you have a few server racks, a backoffice network closet or a small data center, you re under constant pressure to keep your network up and running. And you re no doubt well aware just how vital the right UPS system is to protecting your equipment against damage, downtime and data loss. UPS systems deliver varying levels of protection, ranging from basic Your critical IT equipment requires around-the-clock protection. battery backup and surge protection to on-line operation and zero transfer time to battery. Factors that influence your selection include: The amount of power your connected equipment requires The sensitivity of your equipment The length of backup runtime you need Whether you have whole-site generator backup The voltage of the equipment you re supporting How critical your application is Your available budget Both line-interactive and on-line, double-conversion UPS systems provide excellent protection for 120 V equipment loads up to 3,000 VA. In addition to providing battery backup power, they automatically regulate high- and low-voltage conditions to ensure reliable operation without relying on their batteries. And both types are relatively simple to install, operate and maintain, even for a one-person IT department or an organization with no IT department at all. Although the UPS systems share many similarities, there are also key differences that are important to understand when deciding which type is most appropriate for your particular application. In some cases, you ll even find that an on-line UPS is the right choice for protecting some of your equipment and a lineinteractive UPS is the right choice for protecting other equipment. 3. Tough Decision: On-Line or Line-Interactive UPS?
4 What You Should Know about On-Line, Double-Conversion UPS Systems On-line UPS systems provide the highest level of power protection for servers and other network equipment in data centers, server rooms and network closets. How They Work On-line UPS systems use continuous double conversion (AC to DC to AC) to supply consistently pure output regardless of input power conditions. On-line UPS systems deliver power to connected equipment in a twostep process. First they convert incoming AC power to DC power, then they convert the DC power to conditioned AC power with a pure sine wave. As a result of this continuous double-conversion process, on-line UPS systems eliminate voltage irregularities, frequency variations, EMI/RFI line noise and other power problems. Regardless of the condition of incoming power, on-line UPS systems supply consistently pure power at output. During an outage, on-line UPS systems convert stored DC battery power into AC power. In addition, they automatically bypass internal components and deliver power directly to connected equipment in the On-line UPS systems have an automatic AC bypass to keep equipment powered if there is an internal fault or overload. case of an internal fault or overload that exceeds the overload capacity of the UPS. 4. Tough Decision: On-Line or Line-Interactive UPS?
5 The Biggest Benefits On-line UPS systems provide top-quality protection for even your most mission-critical equipment. Here are several reasons why: Isolation of sensitive equipment. The continuous double-conversion process effectively isolates sensitive equipment from power problems. Zero transfer time. Since DC-to-AC power conversion is integrated into normal operation, there is zero transfer time (0 milliseconds) Extending runtime is as simple as plugging in an external battery pack. between the loss of AC input power loss and the supply of AC backup power converted from stored DC battery power. Zero transfer time ensures that there is no risk of losing or corrupting valuable data. Nearly perfect voltage regulation. On-line UPS systems set the standard for voltage regulation, continuously supplying output within ±2% of the nominal (ideal) voltage. Battery-independent restart. On-line models with this feature are able to pass through power after utility power is restored, even if the battery dies. This eliminates the need for manual restarts at remote sites in the middle of the night. Intelligent operation. Power management software enables remote monitoring and management of energy usage and detailed reporting on operating conditions, as well as the ability to reboot unresponsive equipment from anywhere, anytime. Frequency regulation and conversion. When utility power goes out and generator power kicks in, the frequency of the generator output can be erratic. The double-conversion process ensures that frequency is regulated to prevent equipment damage. Most on-line systems also support frequency conversion from 60 to 50 Hz and vice versa. Extended runtime. External battery packs increase battery backup runtime to last through lengthy power outages. Expandable battery packs support daisy-chaining to increase runtime to match any practical requirement. 5. Tough Decision: On-Line or Line-Interactive UPS?
6 Things to Think About On-line UPS systems clearly deliver high-performance protection. But it s important to look at the big picture. Delivering these extra benefits through continuous double conversion requires extra energy, which reduces efficiency and raises operating costs. Heat output is also higher than other UPS options, an important consideration when including online models in a rack configuration, especially in a location with limited Most on-line UPS systems have an economy mode option that increases efficiency, lowers operating costs and reduces heat output. cooling capacity. However, most on-line systems do have an economy mode option that increases efficiency and reduces heat output by suspending the double-conversion process while the power source remains reliable. 6. Tough Decision: On-Line or Line-Interactive UPS?
7 What You Should Know about Network-Grade Line-Interactive UPS Systems Network-grade* line-interactive UPS systems also protect servers and other network equipment in data centers, server rooms and network closets. Although they don t isolate equipment from power problems to the degree of their on-line counterparts, they still deliver excellent Line-interactive UPS systems use a built-in voltage regulator (transformer) to correct voltage problems without switching to battery. protection against blackouts, brownouts, surges and line noise. And they typically have lower acquisition and operating costs than on-line UPS systems. How They Work Line-interactive UPS systems work quite differently than on-line UPS systems. Line-interactive models include a surge/noise filter, a battery, an inverter/charger and a voltage regulator. Under normal power conditions, line-interactive UPS systems pass input power through the surge/noise filter and voltage regulator to the connected equipment, while the inverter/charger charges the battery for emergency use during an outage (blackout). If voltage fluctuates to abnormally low levels (called a power sag or brownout) or abnormally high levels (called an overvoltage), lineinteractive UPS systems use the built-in voltage regulator to increase or decrease the output voltage to acceptable levels. This feature is also known as automatic voltage regulation (AVR). As long as the input voltage is within the AVR correction range, line-interactive UPS systems regulate the output voltage without using battery power. This is an advantage because frequent switching to battery drains the reserve power intended for an outage and causes wear and tear that reduces the battery s useful lifespan. During an outage, the line-interactive UPS converts the stored DC (battery) power into regulated AC output power to support the connected equipment load. Network-grade models provide sine-wave output from battery. * Line-interactive models intended for desktop applications are usually not recommended for network applications. Desktop models typically do not offer rack installation and sine wave output, nor the same degree of voltage regulation, manageability, serviceability, expandability, availability and resilience as network-grade line-interactive models. 7. Tough Decision: On-Line or Line-Interactive UPS?
8 The Biggest Benefits Network-grade line-interactive UPS systems provide highly reliable protection to your network and connected equipment. Benefits include: Extremely fast transfer time. Because the inverter is not active during normal operation, there s a tiny delay typically 2 to 4 milliseconds during the transfer from AC power to battery backup power. The delay is barely detectable, however, and it is rare for it to cause issues with connected equipment. Power management software helps you remotely monitor energy usage and operating conditions, as well as reboot unresponsive equipment. Excellent voltage regulation. Network-grade line-interactive UPS systems typically regulate voltage within +6% to -14% of normal voltage, which is more than acceptable for almost all equipment. Intelligent operation. Like on-line UPS systems, line-interactive models support power management software to help you remotely monitor energy usage and detailed operating conditions, as well as reboot unresponsive equipment from anywhere, anytime. Extended runtime. External battery packs increase battery backup runtime to last through lengthy power outages. Expandable battery packs support daisy-chaining to increase runtime to match any practical requirement. (Not all line-interactive UPS models support extended runtime, so confirm availability in the specifications if you need this feature.) Operating efficiency. Line mode efficiency is as high as 99%, reducing energy costs and heat output. 8. Tough Decision: On-Line or Line-Interactive UPS?
9 Things to Think About Although network-grade line-interactive UPS systems are comparable in many ways to on-line models, they also have some key differences: First, the output voltage regulation is less precise than on-line model, although still compatible with almost all servers and network equipment. Network-grade line-interactive UPS systems provide excellent power protection, typically at lower cost than on-line models. Second, the transfer time is excellent, but it is a notch below the standard set by on-line models. Third, most line-interactive UPS systems do not have an automatic bypass, so equipment will not remain powered in case of an internal fault or overload. In practice, however, the inherent reliability of the line-interactive architecture makes this feature somewhat less important. Last but not least, line-interactive models do not have batteryindependent restart capability, meaning someone may need to manually restart the UPS when utility power is restored after an outage that exceeds the runtime. On the plus side, line-interactive UPS systems are very cost-effective, requiring less investment in capital and operating costs than their on-line counterparts. And because they produce less heat than on-line models, they are well-suited for installations with limited cooling capacity. 9. Tough Decision: On-Line or Line-Interactive UPS?
10 What Do the Similarities and Differences Mean for Your Application? So now what? As this review indicates, high-performing on-line and line-interactive UPS systems share many similar characteristics but also feature some key differences and performance trade-offs. In general, on-line, double-conversion UPS systems are recommended for: All critical, high-availability network applications Sensitive equipment that requires zero transfer time A line-interactive UPS typically regulates output within +6 to -14% of the nominal voltage, while an on-line UPS system typically regulates within ±2%. In practice, both types provide voltages well within the tolerances of most equipment. Locations with frequent and/or severe voltage problems Locations (especially industrial sites) with exceptionally noisy power Locations with generator backup that requires frequency regulation Applications with frequency conversion needs In general, network-grade line-interactive UPS systems are recommended for: Basic and price-sensitive network applications Applications requiring enhanced efficiency Applications requiring reduced heat output Locations with relatively good on-site power Locations with whole-site generator backup Because of its continuous double-conversion process, an on-line UPS system has zero transfer time between a power failure and the delivery of battery backup power. The transfer time of a line-interactive UPS system is extremely fast (2 to 4 milliseconds) and does not pose a problem for most applications. 10. Tough Decision: On-Line or Line-Interactive UPS?
11 Sample UPS System Comparison: Line-Interactive vs. On-Line Network-Grade Line-Interactive UPS SMART1500RMXL2UA Two high-performance UPS systems with many similarities... On-Line, Double-Conversion UPS SU1500RTXLCD2U 120 V, 1,500 VA (1,350 W) Voltage, Capacity 120 V, 1,500 VA (1,350 W) Pure Sine Wave Output Waveform Pure Sine Wave Yes External Battery Pack Options Yes Advanced LCD Front Panel Display Advanced LCD and LEDs Yes (SNMPWEBCARD) Network Management Card Option Yes (SNMPWEBCARD) USB, Serial (DB9), EPO Built-in Communications Ports USB, Serial (DB9), EPO 2U / 46.5 lb Rack Size / Weight 2U / 45.2 lb 5.9 minutes 33.8 min. (+1 BP36V27-2US) Backup Runtime at 1,200 W (Internal Batteries Only) Backup Runtime at 1,200 W (with External Battery Pack) Yes Hot-Swappable Batteries Yes 5.3 minutes 44.7 min. (+1 BP48V27-2US) Add Hot-Swap PDU (PDUB15) Maintenance Bypass Option Add Hot-Swap PDU (PDUB15)...some notable differences milliseconds (Typical) Transfer Time from AC to Battery Mode Zero Transfer Time (On-Line Mode) +6% / -14% (Worst-Case Scenario) Output Voltage Regulation ±2% (On-Line Mode), ±10% (Economy Mode) No Frequency Regulation 50/60 Hz ±0.05 Hz in Regulation Mode No Frequency Conversion Support for 60-to-50 Hz and 50-to-60 Hz No Automatic Internal Bypass Yes No Battery-Independent Startup Yes 13.5 inches Cabinet Depth 18.5 inches $ and cost and efficiency trade-offs... Annual UPS Energy Cost (1,200 W Load, $0.10 per kwh) $ (On-Line Mode), $67.45 (Economy Mode) 95% UPS Line-Mode Efficiency 90% (On-Line Mode), 94% (Economy Mode) 237 BTU/hr. Heat Output (1,200 W Load) 455 BTU/hr. (On-Line Mode), 292 BTU/hr. (Economy Mode) 0.7 Estimated Acquisition Cost Factor 1.0 Recommended for: Basic and price-sensitive network applications Applications requiring enhanced efficiency Applications requiring reduced heat output Locations with relatively good on-site power Locations with whole-site generator backup...to consider when making the best UPS choice for your application. Recommended for: Critical, high-availability network applications Equipment that requires zero transfer time Sites with frequent/severe voltage problems Sites (like industrial sites) with very noisy power Generators that require frequency regulation Applications requiring frequency conversion 11. Tough Decision: On-Line or Line-Interactive UPS?
12 The Tipping Point Ultimately, selecting the best option for your organization depends on your specific needs, risk tolerance and budget. The good news is that both on-line, double-conversion and network-grade line-interactive UPS systems deliver such high performance and high-quality power protection that you won t go wrong no matter which option you choose. If you would like additional advice and assistance, contact Tripp Lite UPS Application Support at or [email protected]. About Tripp Lite Customers in the IT, telecom, industrial, commercial, corporate, healthcare, government and education sectors choose Tripp Lite for complete solutions to power, protect, connect and manage servers, network hardware and other equipment in data centers and related facilities. Tripp Lite makes more than 3,000 products, including UPS systems, battery packs, PDUs, rack enclosures, cooling solutions, surge protectors, KVM switches, cables, power strips and inverters. For more information about Tripp Lite s full line of data center solutions, visit Tripp Lite. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. 12. Tough Decision: On-Line or Line-Interactive UPS?
Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications
W H I T E P A P E R Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications Executive Summary One of the fundamental decisions in the design of data centers, server rooms
Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course. 2008 Tripp Lite.
Welcome to the Tripp Lite UPS Systems Basics training module, part of Tripp Lite's "Products Expert" training course. 2008 Tripp Lite. All rights reserved. The policy of Tripp Lite is one of continuous
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V
SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS,
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS, Sine
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,
Model #: SMART2200CRMXL
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: [email protected] Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SM1000RM1UTAA Description Tripp Lite SM1000RM1UTAA 1000VA / 1kVA / 800 watt line
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System
Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System MODEL NUMBER: HTR05-1U Description Tripp Lite's HTR05-1U AVR Series intelligent, Automatic Voltage Regulated
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system
Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system Model #: SMART500RT1U 500VA line interactive 1U rack/tower UPS 7 outlets with 1 switchable load bank Simultaneous
SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial
SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMART500RT1U Description Tripp Lite's SMART500RT1U intelligent, line-interactive rack/tower uninterruptible
SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMX750SLT Highlights 750VA line interactive tower UPS; Sine wave output 220/230/240V nominal
SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial
SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1000RT2U Highlights 1kVA / 1000VA / 900W line-interactive 2U rack/tower UPS, Sine
3U, 2200 VA Audio/Video Pure Sine Wave UPS System
3U, 2200 VA Audio/Video Pure Sine Wave UPS System MODEL NUMBER: HTR22-3U Description Tripp Lite's HTR22-3U Pure Sine Wave 2200VA/1600W on-line, double-conversion UPS system prevents media data loss, equipment
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port MODEL NUMBER: OMNIVS1500 Highlights 1500VA / 1.5kVA tower 120V line-interactive UPS Corrects brownouts and overvoltages from 75 to 147V
Common Power Problems & Power Protection Solutions
W H I T E P A P E R Common Power Problems & Power Protection Solutions Executive Summary All systems, from home theaters and office desktops to enterprise IT equipment in data centers, are prone to downtime,
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial MODEL NUMBER: SMART1500SLT Highlights 1.5kVA / 1500VA line interactive tower UPS; Sine wave output
BC Pro UPS System Standby UPS System
BC Pro UPS System Standby UPS System Model #: BCPRO1400 1400VA standby, tower UPS system Offers battery derived AC output during blackouts and brownouts starting at 99V 6 protected AC outlets (NEMA 5-15R)
Internet Office 500VA Tower Standby 120V UPS with USB port
Internet Office 500VA Tower Standby 120V UPS with USB port MODEL NUMBER: INTERNETOFFICE500 Highlights 500VA tower 120V standby UPS Maintains AC output during power failures 3 UPS battery supported outlets,
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets MODEL NUMBER: BC600SINE Highlights 600VA tower 120V standby UPS with SINE WAVE output Maintains AC output during power
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA -3000VA Intelligent, Reliable UPS Protection Liebert
Internet Office UPS System Standby UPS for PCs, workstations and more
Internet Office UPS System Standby UPS for PCs, workstations and more Model #: INTERNETOFFICE500 500VA standby tower UPS system Offers battery-derived AC output during blackouts and brownouts starting
Internet Office 750VA Ultra-compact Standby 120V UPS with USB port
Internet Office 750VA Ultra-compact Standby 120V UPS with USB port MODEL NUMBER: INTERNET750U Highlights 750VA ultra-compact 120V standby UPS Maintains AC output during power failures 6 UPS battery supported
A COMPARISON OF TYPICAL UNINTERRUPTIBLE POWER SUPPLY (UPS) DESIGNS IN TODAY S MARKETS
A COMPARISON OF TYPICAL UNINTERRUPTIBLE POWER SUPPLY (UPS) DESIGNS IN TODAY S MARKETS October 22, 2010 Authored by: Kevin Binnie, Senior Product Portfolio Manager ALPHA TECHNOLOGIES LTD. Executive Summary
IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS
IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS Executive Summary IT managers who are used to implementing power protection for IT network or data
For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on
Home Sign In View Cart Order Status Search Solutions Products and Services Support Your Business Company Data Center Server Rooms Solutions for Small-Medium Data Center Large Data Centers Cloud & Co-location
Technical Comparison of On-line vs. Line-interactive UPS designs
Technical Comparison of On-line vs. Line-interactive UPS designs By Jeffrey Samstad Michael Hoff White Paper #79 Executive Summary UPS systems below 5000VA are available in two basic designs: line-interactive
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
DATA CENTER SOLUTIONS
DATA CENTER SOLUTIONS Nobody Makes Better Data Center Equipment Maximize availability, manageability and efficiency with cost-effective solutions from a dependable partner. Provide reliable, efficient
Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS
Smart-UPS Advanced line interactive power protection for servers and network equipment The world s most popular network and server UPS The award-winning Smart-UPS unit from APC by Schneider Electric is
Galleon 6-10K Online UPS. Voltronic Power Technology Corporation
Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection
PowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
LAP ENERGIA PARA DATACENTERS
LAP ENERGIA PARA DATACENTERS Latin American Power. CABA, Argentina. 2 UPS INDOOR Latin American Power. CABA, Argentina. ALI ELITE SERIES Line Interactive UPS Tower/19 Rack Mount Versions 19 Rack Mount
Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V
Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V APC Smart-UPS, 670 Watts / 1000 VA,Input 230V / Output 230V, Interface Port DB-9 RS-232, SmartSlot, USB Includes: CD with software, Smart UPS signalling
NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.
NEW APC Smart-UPS Advanced line interactive power protection for servers and network equipment. > The world s most popular network and server UPS. Award-winning Smart-UPS protects critical data by supplying
Power Quality. Uninterruptible Power Supply
Quality Uninterruptible Supply In the electrical system environment, power disturbances will occur. These can be caused by faults on the distribution system, the operation of nearby equipment, lightning
Dell Smart-UPS 1,500 3,000 VA
Dell Smart-UPS,00,000 VA 0 V Advanced line interactive power protection for servers and network equipment Reliable. Intelligent. Efficient. Manageable. Engineered by APC by Schneider Electric, the Dell
Selecting a UPS Topology for your Data Center. by Dr. Daniel Becker, Ph.D., Methode Active Energy Solutions
Selecting a UPS Topology for your Data Center by Dr. Daniel Becker, Ph.D., Methode Active Energy Solutions Uninterruptible Power Supplies (UPS) are both reaching into new markets and expanding in new ways
Choosing Close-Coupled IT Cooling Solutions
W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of
Top 8. Considerations for Choosing the Right Rack Power Distribution Unit to Fit Your Needs
Power design in data centers is getting substantial attention particularly by facilities and engineering personnel as organizations pursue constant improvements in reliability and energy efficiency. At
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.
NEW APC Smart-UPS Advanced line interactive power protection for servers and network equipment. > The world s most popular network and server UPS. Award-winning Smart-UPS protects critical data by supplying
Intelligent Power Distribution in the Data Center
Rack Power Intelligent Power Distribution in the Data Center Agenda Data Centre Power UPS Power Distribution Rack Mount PDU s UPS Power problems Configuration Capacity Power Distribution Types of Distribution
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,
Back-UPS 650 VA 120 V with AVR (BX650CI-LM)
Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit
APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply
APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality
Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA
Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA Liebert GXT3 is a full feature UPS providing reliable protection for IT network equipment and data centers. It is a true
Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE
Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication
Finding the Right Cooling and Power Solutions for VoIP
S p e c i a l R e p o R t Finding the Right Cooling and Power Solutions for VoIP by Elisabeth Horwitt Sponsored Exclusively by: Special Report Finding the Right Cooling and Power Solutions for VoIP As
The UPS for the highest security in industry and data centres
The UPS for the highest security in industry and data centres P R E M I U M 6,000-20,000VA T E C H N O L O G Y www.online-usv.de Perfect: The ultimate protection against blackout and data loss The new
Single Phase UPS Management, Maintenance, and Lifecycle
Single Phase UPS Management, Maintenance, and Lifecycle White Paper 210 Revision 0 by Justin Solis Executive summary How long will my battery last? and what is the best practice for maintaining my UPS?
Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview
Overview The industry leading packs up to 3000 watts into a space saving 2U design. Proven Digital Signal Processor (DSP) double conversion system provides clean, reliable power protection in an energy
PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR
PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR CLASSIFICATION CLASSIFICATION ACC. TO - AEG S UPS PRODUCT PORTFOLIO - IT S APPLICATION ORIENTED USE - UPS PRODUCT
HP R/T3000 G2 Uninterruptible Power System (UPS) Overview
Overview The industry leading packs up to 3000 watts into a space saving 2U design. Proven Digital Signal Processor (DSP) double conversion system provides clean, reliable power protection in an energy
Maximizing UPS Availability
Maximizing UPS Availability A comparative assessment of UPS designs and deployment configurations for the highavailability data center By Chris Loeffler Product Manager, BladeUPS & Data Center Applications
Practical Power Guidelines for Cisco VoIP and Internet Telephony Applications
www.tripplite.com Practical Power Guidelines for Cisco VoIP and Internet Telephony Applications by David Slotten Tripp Lite is a Cisco Technology Developer Partner in the Cisco Technology Developer Program.
Eaton 93PM UPS Where aesthetics meet intelligence.
Brochure 100 kw Eaton 93PM UPS Where aesthetics meet intelligence. 93PM features and benefits The Eaton 93PM UPS combines unprecedented and reliability with eye-catching design. A space-saving, flexible
QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview
Overview The Tower UPS "G2" models are the next generation HP tower UPSs with USB support. These new UPSs are designed to provide advanced power protection (or increased uptime and data corruption avoidance)
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity
The Quest for Energy Efficiency A White Paper from the experts in Business-Critical Continuity Abstract One of the most widely discussed issues throughout the world today is the rapidly increasing price
Which UPS is right for the job?
Which UPS is right for the job? Considerations in choosing standby, line-interactive, double-conversion designs and new high-efficiency, multi-mode capabilities for your data center By Chris Loeffler Data
Fundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
3.5in esata USB Dual Removable SATA RAID External Hard Drive Enclosure StarTech ID: S352U2RER
3.5in esata USB Dual Removable SATA RAID External Hard Drive Enclosure StarTech ID: S352U2RER This esata/usb External Dual SATA Hot-swap Hard Drive Enclosure lets you install two 3.5in SATA (SATA, SATA
Galaxy VM. Three-phase power protection. schneider-electric.com
Galaxy VM Three-phase power protection schneider-electric.com 2 schneider-electric.com schneider-electric.com 3 Galaxy VM trusted partner for your business continuity Features and benefits Highly efficient,
Power and Cooling Best Practices for IP Communications. A White Paper from the Experts in Business-Critical Continuity
Power and Cooling Best Practices for IP Communications A White Paper from the Experts in Business-Critical Continuity Executive Summary IP telephony and Power over Ethernet (PoE) are driving the requirement
Always On UPS Systems Inc., #100-150 Campion Road, Kelowna, BC Canada V1X 7S8
Door Mount UPS (Patent Pending) Shelf Mount UPS (Patent Pending) DESCRIPTION: The Always On NDM (door mount) and NSM (shelf mount) Series UPS s are dual conversion online UPS systems provided in slim,
QuickSpecs. Compaq Uninterruptible Power Systems M ODELS
M ODELS Rack-Mountable UPS Models 242704-001 242705-001 h-na 242705-003 Tower UPS Models 295372-B21 242688-001 242688-003 242688-005 T2400h-NA 242688-007 OVERVIEW Compaq UPS Products Compaq has developed
UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES
UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES 9900A The 9900A UPS system uses the most advanced IGBT in both the converter and inverter with Digital Signal Processor (DSP)
Installation and Operation Back-UPS 1250, 1300, 1500
Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
PowerPanel Business Edition USER MANUAL
USER MANUAL Rev. 0.9 2007/10/26 Copyright 2006-2007 Cyber Power Systems, Inc. All rights reserved. PowerPanel Business Edition USER S MANUAL PowerPanel Business Edition provides power management Services.
R5000 Uninterruptible Power System (UPS) Overview
Overview The innovative Minimally Switched Technology used in the HP R5000 UPS improves the performance over traditional line-interactive UPS designs while reducing the cost, weight, and size of traditional
User s Manual AURORA 1.2K/2.2K
User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable
R5000 Uninterruptible Power System (UPS) Overview
Overview The innovative Minimally Switched Technology used in the HP R5000 UPS improves the performance over traditional lineinteractive UPS designs while reducing the cost, weight, and size of traditional
Back-UPS Pro 1300/1500 Installation and Operation
Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a
UPS For Efficient Data Data Centers Centers
UPS For Efficient Data Centers Eaton Corporation Agenda (1) Introduction Basics About UPS s (2) Trends and Challenges Affecting The Power Infrastructure Of Your Data Center (3) Selecting The Right Power
Cisco Redundant Power System 2300
Cisco Redundant Power System 2300 The Cisco Redundant Power System 2300 (RPS 2300) increases availability for converged data, voice, and video networks. The system delivers power supply redundancy and
Enterprise Remote Monitoring
Enterprise Remote Monitoring Alarm Management, Predictive Maintenance, Advanced Network Security Services For Business-Critical Continuity Can You Really Afford Not To Know? Loss of productivity and the
Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity
Modular architecture for high power UPS systems A White Paper from the experts in Business-Critical Continuity Abstract Today, more than ever before, energy efficiency and cost-savings are among the top
Smart-UPS On-Line 230 V
Smart-UPS On-Line 230 V Unity output power factor single-phase, double-conversion online UPS with advanced management features A versatile UPS developed for unstable power conditions worldwide Smart-UPS
The Avocent Data Center Planner Real-World Insight for Smarter Data Center Management
Infrastructure Management & Monitoring for Business-Critical Continuity TM The Avocent Data Center Planner Real-World Insight for Smarter Data Center Management EXECUTION AVAILABILITY EFFICIENCY What s
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
RIELLO ELETTRONICA. Master HP
RIELLO ELETTRONICA Master HP LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCS ELECTRO- MEDICAL DEVICES
How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit
Overview Power protection in the data center is critical to maintain up time, and the increased densities in data centers is driving the need for uninterruptible power with increased power density, power
Online UPS. PowerWalker VFI 1000R/1U
Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.