INDICE MINI-CONTATTORI / CONTENTS MINI-CONTACTORS. Criteri di scelta pag Product selection. Caratteristiche tecniche pag Tecnical data
|
|
- Dwight James
- 8 years ago
- Views:
Transcription
1 Indice Contents CONTROLLO MOTORE MOTOR CONTROL INDICE MINICONTTTORI / CONTENTS MINICONTCTORS Criteri di scelta pag. 8 Product selection Caratteristiche tecniche pag. Tecnical data 77
2 Criteri di scelta Product selection MINI CONTTTORI MINI CONTCTORS CONTTTORI TRIPOLRI circuito di c.a. THREEPOLE CONTCTORS a.c. control Potenza nominale motori trifase 060Hz phase motors 060Hz rated power C, C V 0V 80V 0V 00V 690V kw kw kw Corrente nominale Collegamenti Rated current Connections C, C 80V 00V ausiliari uxiliary contacts NO NC Tensione di 9 GHMC..0 GHMC..0 0,6 0,6 GHMCP..0 GHMCP..0 0,6 0,6,, GHMD..0 GHMD..0 0,6 0,6 CONTTTORI TRIPOLRI circuito di c.c. THREEPOLE CONTCTORS d.c. control 9 GHMC..0 GHMC..0 0,9 0,9 GHMCP..0 GHMCP..0 0,9 0,9,, GHMD..0 GHMD..0 0,9 0,9 CONTTTORI TETRPOLRI circuito di c.a. FOURPOLE CONTCTORS a.c. control Corrente nominale Rated current C 690V Collegamenti Connections ausiliari uxiliary contacts GHMC..00 GHMD..00 GHMCP..00 Tensione di 0,6 0,6 CONTTTORI TETRPOLRI circuito di c.c. () FOURPOLE CONTCTORS d.c. control () GHMC..00 GHMD..00 GHMCP..00 0,9 0,9 Completare il riferimento con la tensione e la frequenza della bobina di. Le tensioni normalizzate disponibili sono le seguenti: Complete catalogue with details of and frequency control circuit coil. Standard available control s are the following: V 060Hz V DC 0V 0Hz e V 60Hz 8V DC 0V 0Hz e 0V 60Hz 0V DC 8000V 0Hz e 0V 60Hz () Sono disponibili su richiesta minicontattori con poli principali NO+NC (es. GHMC..00). Minicontactors with NO+NC main poles (ex. GHMC..00) are also available on request. 8
3 Criteri di scelta Product selection CONTROLLO MOTORE MOTOR CONTROL INVERTITORI TRIPOLRI circuito di c.a. THREEPOLE REVERSERS a.c. control Potenza nominale motori trifase 060Hz phase motors 060Hz rated power C, C V 0V 80V 0V 00V 690V kw kw kw Corrente nominale Collegamenti Rated current Connections C, C 80V 00V ausiliari uxiliary contacts NO NC Tensione di 9 GHMC..0/R GHMC..0/R 0, 0, GHMCP..0/R GHMCP..0/R 0, 0,,, GHMD..0/R GHMD..0/R 0, 0, INVERTITORI TRIPOLRI circuito di c.c. THREEPOLE REVERSERS d.c. control 9 GHMC..0/R GHMC..0/R 0,8 0,8 GHMCP..0/R GHMCP..0/R 0,8 0,8,, GHMD..0/R GHMD..0/R 0,8 0,8 INVERTITORI TETRPOLRI circuito di c.a. FOURPOLE REVERSERS a.c. control Corrente nominale Rated current C 690V Collegamenti Connections ausiliari uxiliary contacts INVERTITORI TETRPOLRI circuito di c.c. FOURPOLE REVERSERS d.c. control GHMC..00/R GHMCP..00/R Tensione di 0, 0, GHMC..00/R 0,8 GHMCP..00/R 0,8 Completare il riferimento con la tensione e la frequenza della bobina di. Le tensioni normalizzate disponibili sono le seguenti: Complete catalogue with details of and frequency control circuit coil. Standard available control s are the following: V 060Hz V DC 0V 0Hz e V 60Hz 8V DC 0V 0Hz e 0V 60Hz 0V DC 8000V 0Hz e 0V 60Hz 99
4 Criteri di scelta Product selection MINI CONTTTORI MINI CONTCTORS CONTTTORI USILIRI circuito di c.a. UXILIRY CONTCTORS a.c. control Corrente termica Ith Thermal current Ith Corrente nominale Rated current C 0V 00V Collegamenti Connections Contacts NO NC Tensione di 0 GHMR.0 0,6 GHMR. 0,6 GHMR. 0,6 CONTTTORI USILIRI circuito di c.c. UXILIRY CONTCTORS d.c. control 0 GHMR.0 0,9 GHMR. 0,9 GHMR. 0,9 BLOCCHETTI GGIUNTIVI DI CONTTTI USILIRI DDITIONL UXILIRY CONTCT BLOCKS 0 GHTR. 0,0 GHTR.0 0,0 GHTR.0 0,0 GHTR. 0,0 GHTR..V () 0,0 Completare il riferimento con la tensione e la frequenza della bobina di. Le tensioni normalizzate disponibili sono le seguenti: Complete catalogue with details of and frequency control circuit coil. Standard available control s are the following: V 060Hz V DC 0V 0Hz e V 60Hz 8V DC 0V 0Hz e 0V 60Hz 0V DC 8000V 0Hz e 0V 60Hz () Da utilizzare nel caso di invertitore per il contattore sinistro To use for the left contactor of the reverser 0
5 Caratteristiche tecniche Technical data CONTROLLO MOTORE MOTOR CONTROL CRTTERISTICHE TECNICHE SECONDO LE NORME EN 6097 DT CCORDING TO IEC 6097 di potenza Main contacts GHMC GHMCP GHMD Tensione di isolamento Potere di chiusura Potere di interruzione cos ϕ 0,6 Rated insulation Making capacity Breaking capacity cos ϕ 0,6 Ui Ue = 690V a.c. 00V a.c. 00V a.c. 690V a.c. [V] a.c Categoria di impiego C di carichi resistivi Max. 0 C corrente nominale Ie (=Ith) a giorno Potenza max. carichi trifase resistivi Max. 60 C corrente nominale Ie (=Ith e ) in cassetta Potenza max. carichi trifase resistivi Sezione minima connessioni a Ie Utilization category C switching of resistive loads Rated operational current Ie (=Ith) at 0 C, open threephase resistive loads 0V 0V 00V V Rated operational current Ie (=Ith e ) at 60 C, enclosed threephase resistive loads 0V 0V 00V V Minimum crosssection of conductor at Ie [mm ] 7,9 8,,8, 6 6, 6,7,, 7,9 8,,8, 6 6, 6,7,, Categoria di impiego C, C di motori elettrici trifase Potenza nominale di motori trifase Utilization category C, C switching of threephase motors Rated operational current Ie threephase motors V 0V 0V 80 00V 0V 00V V 0V 80 0V V, 9 8 7, 9 6,,, Categoria di impiego C di motori a gabbia, frenatura in controcorrente, marcia ad impulsi Potenza nominale di motori trifase Utilization category C switching of squirrel cage motors, plugging, inching Rated operational current Ie threephase motors V 0V 0V 80 00V 0V 00V V 0V 80 0V V, 9 8 7, 9 6,,, Categoria di impiego DC di carichi resistivi in c.c. Costante di tempo L / R ms Utilization category DC switching of d.c. resistive loads Time costant L / R ms Rated operational current Ie polo / pole V 60V 0V V poli in serie / poles in series V 60V 0V V 0,6 6 0,6 6 GHMC, MD, MR, GHTR datto a 690V per: sistemi con neutro a terra, categoria di sovratensione da I a IV, grado di inquinamento (industriale normale): Uimp = 8kV GHMCP, MRP datto a 690V con grado di inquinamento, Uimp = 6kV Grado di inquinamento : Ui = 690V con circuito stampato CTI Ui = 00V con circuito stampato CTI 00 Ui = 00V con circuito stampato CTI 00 GHMC, MD, MR, GHTR Suitable at 690V for: earthedneutral systems, over category I to IV, pollution degree (standardindustry): Uimp = 8kV. GHMCP, MRP Suitable at 690V for pollution degree, Uimp = 6kV Pollution degree : Ui = 690V printed circuit CTI Ui = 00V printed circuit CTI 00 Ui = 00V printed circuit CTI 00
6 Caratteristiche tecniche Technical data MINI CONTTTORI MINI CONTCTORS di potenza Categoria di impiego DC e DC di motori in c.c. Costante di tempo L / R ms Max. temperatura ambiente Funzionamento a giorno in cassetta Con relè termico a giorno in cassetta Stoccaggio Protezione contro il corto circuito per contattore senza relè termico Main contacts Utilization category DC and DC switching of shunt and series d.c. motors Time costant L / R ms Rated operational current Ie Max. ambient temperature Operation With thermal o/l relay Storage Short circuit protection for contactor without thermal relay polo / pole V 60V 0V V poli in serie / poles in series V 60V 0V V open enclosed open enclosed GHMC GHMCP 0, GHMD 0, coordinamento tipo secondo EN 6097 coordinationtype according to IEC 6097 gl (gg) 0 0 coordinamento tipo secondo EN 6097 Sezione delle connessioni rigide o semirigide flessibili flessibili con puntalino Numero cavi per terminale Max. frequenza di manovre Contattore senza relè termico Max. temperatura ambiente Funzionamento a giorno in cassetta Stoccaggio Protezione contro il corto circuito corrente di corto circuito k Sezione delle connessioni rigide o semirigide flessibili flessibili con puntalino Numero cavi per terminale Vedi nota pag. See note page coordinationtype according to IEC 6097 gl (gg) Cable crosssections solid or stranded flexible flexible with multicore cable end Cables per terminal Frequency of operations Contactor without relay a vuoto / without load C Ie C Ie DC Ie Corrente di breve durata Short time current 0s Potenza dissipata per polo a: Power loss per pole at: max. Ie C 00V Durata meccanica Fissaggio ausiliari Tensione di isolamento Corrente termica Ith Potenza dissipata per polo a Ith Categoria di impiego C Categoria di impiego DC Mechanical endurance Fixing uxiliary contacts.c. D.C. Rated insulation Ui Thermal current Ith max. 0 C max. 60 C Power loss per pole at Ith Utilization category C 0V Rated operational current Ie 80V 0V 00V V Utilization category DC 60V Rated operational current Ie 0V V Max. ambient temperature Operation Storage open enclosed [mm ] [mm ] [mm ] [op/h] [op/h] [op/h] [op/h] [W] [0 6 op] [0 6 op] viti/screw o/or DIN GHMR GHMRP GHTR [V] a.c [W] 0. 0.,6, 0,6 0, 0, ,6, 0,6 0, 0, Short circuit protection shortcircuit current k gg Cable crosssections solid or stranded [mm ] flexible [mm ] flexible with multicore cable end [mm ] Cables per terminal
7 Caratteristiche tecniche Technical data CONTROLLO MOTORE MOTOR CONTROL Circuito di circuit ssorbimento bobina Corrente alternata Corrente continua Power consumption of coils.c. operated D.C. operated spunto / inrush ritenuta / sealed spunto / inrush ritenuta / sealed [V] [V] [W] [W] [W],,, Campo di funzionamento della bobina in multipli della tensione di Us Tempo di funzionamento a tensione di Us ± 0% Corrente alternata tempo di chiusura tempo di rilascio durata dell'arco Corrente continua tempo di chiusura tempo di rilascio durata dell'arco Operation range of coils in multiplies of control Us Switching time at control Us ± 0%.C. operated D.C. operated.c. D.C. make time release time arc duration make time release time arc duration 0, Dati secondo UL Data according to UL GHMC* GHMD* GHMR* Corrente nominale "General Use" Rated operational current "General Use" 0 Potenza max. motori trifase 60 Hz Potenza max. motori monofase 60 Hz Fusibili Corrente massima di c.c. presunta Tensione nominale threephase motors at 60 Hz singlephase motors at 60 Hz Fuses Max. short circuit prospective current Rated V 0V 0V 60V 7V V 0V 0V.C. [V] [V], 7, 0,, , 0 0,7, ausiliari codice di designazione uxiliary contacts switching capacity.c. D.C. Q Q Q Versioni omologate UL / UL listed types: Contattori / Contactors Invertitori / Reversers GHMC..0 GHMC..0 GHMCP..0 GHMCP..0 GHMC..00 GHMCP..00 GHMD..0 GHMD..0 GHMD..00 GHMC..0/R GHMCP..0/R GHMD..0/R Contattori ausiliari uxiliary contactors GHMR. GHMR. GHMR.0 GHMRP. GHMRP. GHMRP.0 Blocchi contatti ausiliari uxiliary contact blocks GHTR GHTR0 GHTR0 GHTR Pollution degree CTI PWB Ui 00 V 00 80V V
8 MINI CONTTTORI MINI CONTCTORS
MINI CONTATTORI / MINI CONTACTORS
Informazioni generali / General information pag. 54 Caratteristiche tecniche / Technical datas pag. 57 Codici di ordinazione / Ordering product codes pag. 60 53 CONTTTORI TRIPOLRI CIRCUITO DI COMNDO C..
More informationMicro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
More informationInterruttori di manovra sezionatori Switch disconnectors
Interruttori di manovra sezionatori Switch disconnectors SD generalità generalities codici per l ordinazione order references dati tecnici technical data dimensionali dimensions accessori accessories I
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationInterruttori di manovra sezionatori 16 125 A 11SD. Switch disconnectors
Interruttori di manovra sezionatori 16 125 A 11SD Switch disconnectors 11 Interruttori di manovra sezionatori Switch disconnectors SD GENERALITA Gli interruttori-sezionatori modulari della serie SD, consentono
More informationAlimentatori LED LED drivers
Alimentatori LED LED drivers ALimentatori LED LED drivers Alimentatori disponibili in diverse potenze e dimensioni con caratteristiche tecniche specifiche per settore di utilizzo Alimentatori per applicazioni
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationanalog SENSORI INDUTTIVI ANALOGICI inductive analog sensors
Sensori di prossimità induttivi con uscita analogica Inductive proximity sensors with analogue output a Caratteristiche principali Main features > Ampia scelta di dimensioni: M, M2 e M > Wide choice of
More informationSerie ET / ET Series
Sensori di prossimità induttivi con campo di temperatura di lavoro esteso Extended working temperature range proximity inductive sensors Corpo in acciaio inox / stainless steel housing Modelli M12, M18
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More information13/30 SERIES / SERIE 13/30 EIA 1 5/8 SERIES / SERIE EIA
13/30 SERIES / SERIE 13/30 EIA 1 5/8 SERIES / SERIE EIA 1 5/8 EIA 1 5/8 CONNECTORS CONNETTORI EIA 1 5/8 2 Main Characteristics - Low reflection coefficient (up to 3 GHz) - Low IMD3 value (-162dBc) - Inner
More informationContenitori Enclosures
- 19 - Contenitori Enclosures Contenitori in materiale termoplastico per ausiliari di comando Ø 22 Thermoplastic enclosures suitable for control units Ø 22 Dati tecnici generali / General Technical Data
More informationC Series. 16(5)A at 250V A.C 50Hz. 3A at 30V D.C. L/R=5ms 10 milioni di operazioni a 1 Hz / million operations at 1Hz 1250Vrms at 50Hz
C Series Il microinterruttore della serie C é un trasduttore elettromeccanico capace di commutare carichi fino a 20A, è dotato di lunga vita, bassa corsa differenziale, alta ripetibilità e buona resistenza
More informationMADE IN ITALY. Sistemi di connessione per fotovoltaico Connection systems for photovoltaic. TÜV certification EN 50521:2008 SC3
Sistemi di connessione per fotovoltaico Connection systems for photovoltaic TÜV certification EN 505:008 SC Tipologia di prodotto Definizione modelli Informazioni Valori nominali Indice Index Datasheet
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationMotori elettrici corrente continua. DC motors MCC
03 G 20 -IN ITA Motori elettrici corrente continua DC motors MCC MOTORI IN C.C. S INDICE - INDEX Riferimento Reference Motore tipo Motor type Pagina Page Riferimento Reference Motore tipo Motor type Pagina
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationS-M series, connectors with modular inserts Serie S-M, connettori con inserti modulari 12.01
S- series, connectors with modular inserts Serie S-, connettori con inserti modulari.0 S- series, connectors with modular inserts Serie S-, connettori con inserti modulari Contents - Sommario Pages-Pagine
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationISOpro T1+T2. Linea PROTECTION
ISOpro T1+T Scaricatori di corrente da fulmine e sovratensione ad alta prestazione da installare nella parte iniziale di distribuzioni a bassa tensione, per prevenire gli effetti derivanti da fenomeni
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationserie FX3 e FX4 - FX3 and FX4 series
serie FX3 e FX 26-0-200 10:08 Pagina 1 SOMMARIO - INDEX AMPLIFICATORE PER FIBRA OTTICA DA GUIDA DIN SERIE FX3 E FX FIBER-OPTIC AMPLIFIER FOR DIN RAILS FX3 AND FX SERIES Elenco delle caratteristiche funzionali
More informationDISTRIBUTORI ROTANTI ELETTRICI E ELETTRO-IDRAULICI ELECTRO-HYDRAULIC ROTARY COUPLING
t HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES HT / A / 50 / 006 / IE DISTRIBUTORI ROTANTI ELETTRICI E ELETTRO-IDRAULICI ELECTRO-HYDRAULIC ROTARY COUPLING INDICE - INDEX DISTRIBUTORI
More informationSERIE FX3 e FX4 - FX3 and FX4 SERIES
SERIE FX3 e FX - FX3 and FX SERIES SERIE FX3 e FX - FX3 AND FX SERIES SOMMARIO - INDEX AMPLIFICATORE PER FIBRA OTTICA DA GUIDA DIN SERIE FX3 E FX FIBER-OPTIC AMPLIFIER FOR DIN RAILS FX3 AND FX SERIES Elenco
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationAnelli Rings (1) (1) (2) (2) (3) TIPI - TYPES CARATTERISTICHE FEATURES. 1mm 3 24Vdc 10 30Vdc 10 30Vdc 10% 10% 200 ma.
Interruttori di prossimità induttivi D NELLO Negli interruttori di prossimità ad anello il rilevamento avviene all interno dell anello stesso. Il campo di azione è regolabile mediante vite potenziometrica.
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationHow To Build A Powerboat
Serie A / A series Caratteristiche principali / ain features Dimensioni ridotte Compact size fino a 3(4)A up to 3(4)A Colori e marcature personalizzabili Colours and marking customizable Cappuccio antispruzzo
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationSERVOMOTORI BRUSHLESS BRUSHLESS SERVOMOTORS
SERVOMOTORI BRUSHLESS BRUSHLESS SERVO P R O L I N E SERVOMOTORI BRUSHLESS BRUSHLESS SERVO 40-60 - 80 3 PROLINE S040 - PRESTAZIONI E SPECIFICHE PROLINE S040 - PERFORMANCE AND SPECIFICATIONS Tipo - Type
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More informationMcSmart 160C. McSmart 160C INDICE / INDEX SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM
2 3 McSmart 16C INDICE / INDEX SCHEMA ELETTRICO CHILLER / CHILLER CIRCUIT WIRING DIAGRAM SCHEMA ELETTRICO CON VARIATORE DI VELOCITA' VENTILATORI / FAN SPEED MODULATION WIRING DIAGRAM McSmart 16C 18275
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationInstallation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201
Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
More informationDenominazione tavola - Table definition Valida per i modelli - Apply to models N tavola RAV4300 - RAV4300DC - RAV4350 Table no.
Denominazione tavola - Table definition Valida per i modelli - Apply to models N tavola RAV4300 - RAV4300DC - RAV4350 Table no. RAV4350A - RAV4350DC - RAV4351 (MONOFASE 50-60 Hz) RAV4351T - RAV4352 - RAV4355
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationCatalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationPOMPE ROTOMEC. ELETTROPOMPE SOMMERGIBILI Submersible pumps. IMPIEGO - Application. DESCRIZIONE - Description. DATI ELETTRICI - Electric data
POMPE ROTOMEC ELETTROPOMPE SOMMERGIBILI Submersible pumps UNI EN ISO 9-8 serie 5 TR.6 H (m) GIRANTE VORTEX - Vortex impeller 96 Giri / - R.P.M. Curve secondo ISO 996 Liv: (P).... 5 5 6 7 5 5 l/sec Q m³/h
More informationDESCRIPTION DESCRIZIONE
ssptl7r- 04/2014 Cassetta con finecorsa trasmettirore di posizione - Limit switch box position transmitter Disponibile - Available 94/9/EC (ATEX) PTL7 è una cassetta interamente realizzata in Alluminio
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationwww.motorpowerco.com ESA
www.motorpowerco.com ESA ESA Una serie di servomotori a magneti permanenti sinonimo di durata, affidabilità e prestazioni dinamiche. Questa gamma completa, con coppie comprese tra 0,32 e 15 Nm, è l'ideale
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationSwitching Devices Contactors and Contactor Assemblies Special Applications
Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),
More information020-inox 025-inox 040-inox 050-inox 070-inox 080-inox Elettropompe autoadescanti / Self-priming electric pumps
080-inox 070-inox 050-inox 020-inox DESCRIZIONE E APPLICAZIONI Elettropope autoadescanti in acciaio inox AISI 316 ad anello liquido laterale largaente utilizzate nei settori nautico, agricolo ed industriale
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationKIT MODULO LED E DRIVER PER ILLUMINAZIONE ESTERNA E INDUSTRIALE KIT LED MODULE AND DRIVER FOR OUTDOOR AND INDUSTRIAL LIGHTING
12 IT MODULO LED E DRIVER PER ILLUMINAZIONE ESTERNA E INDUSTRIALE POER 30 700 ma TESTO HL 30 equivalente: 30-50-70 HID Consumo: 35 Lumens reali: 2.400 Lumen per att : 80 Equivalent : 30-50-70 HID Consumption:
More informationRELAYS E ACCESSORI FUSIBILI E PORTAFUSIBILI
6 RELAYS E ACCESSORI FUSIBILI E PORTAFUSIBILI relays and accessories fuses and fuseholders 103 MICRO RELAYS 12V. PER AUTO 12V micro relays for cars DIMENSIONI / dimensions: 26x15x23 mm COD. ART. 201006
More informationThermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationCATALOGO LED / LED CATALOGUE
ALED A Alimentatori elettronici per led IP. Uscita in corrente costante 350mA e 700mA. Classe II di isolamento contro scariche elettriche per contatto diretto ed indiretto. Protezione contro il cortocircuito,
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationPreventa Machine Safety Products
Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop
More informationTHERMAL RELAYS, MOTORSTARTERS
THERMAL RELAYS, MOTORSTARTERS MH mini thermal relay plugged version H0K thermal relay with adapter H0K thermal relay plugged version T I thermal relay plugged version H thermal relay with current transformer
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationALIMENTAZIONE POWER SUPPLY
ALIMENTAZIONE POWER SUPPLY Sommario / TOC CONNETTORI PER BATTERIA... 230 BATTERY CONNECTORS CONTROLLI CARICA BATTERIA... 236 BATTERY CHARGE CONTROLS CONVERTITORI DI TENSIONE... 236 DC-DC CONVERTERS INTERRUTTORI
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationCONTATORE ENEL MONOFASE/TRIFASE CONTATORE TRIFASE DI ENERGIA ELETTRICA FIGURA 1: SCHEMA DI INSTALLAZIONE
400 imp/kwh CONTATORE TRIFASE DI ENERGIA ELETTRICA Lo strumento in questione occupa 4 DIN (4X18 mm) e si alloggia facilmente in un normale quadretto, che abbia la guida DIN, lo strumento va installato
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationCAVI CANDELA ignition cables
GRUPPI CAVI ANTIDISTURBO Suppressing sets MARCA/maker MODELLI/models 7641 PEUGEOUT 7642 PEUGEOUT 7493 PEUGEOUT 106 950/1,1DOPO 91-205 MOT. TU DOPO 88 405 1,4 CARB. DOPO 88 106 950 DOPO 92-1,1 DOPO 93-1,4
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationFX3 - FX4 SERIES. SENSORI FOTOELETTRICI A FIBRA OTTICA - SERIE FX FX series - photoelectric sensors FOR OPTICAL FIBRES FX3/0P-0A
SENSORI FOTOELETTRICI FIBR OTTIC - SERIE FX mplifiatore per fibra ottia da guida DIN serie FX3 e FX mplifier unit for optial fibres - DC FX3 and FX series Caratteristihe prinipali Main features > mplifiatore
More informationc-pro nano RACK & c-pro micro RACK
c-pro nano RACK & c-pro micro RACK Controllers for compressor racks Controllori per centrali frigorifere c-pro nano RACK and c-pro micro RACK are a range of controllers for the management of compressor
More informationSensori induttivi conformi alle norme DIN 19234 CENELEC EN 50014-EN 50020 NAMUR (3) CARATTERISTICHE FEATURES. 2mm 3 24 Vdc 10%
Interruttori di prossimità induttivi NON MPLIFICTI NMUR Sensori induttivi conformi alle norme DIN 34 TIPI - TYPES Ø 6,5 Ø 6,5 Ø 6,5 Ø8 Ø8 Ø6,5 Ø6,5 Ø6,5 M8x1 M8x1 NMUR SW13 SW13 CRTTERISTICHE FETURES Schermato
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationSafety detection solutions
Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking
More informationPRESSACAVI CABLE GLANDS
CTLOGO GENERLE / GENERL CTLOGUE PRESSCVI CLE GLNDS SERIE SERIES PGIN PGE 8.1 PRESSCVI STGNI PER CVO RMTO P-PE-PS 8-2 SEMPLICE TENUT WTER-DUSTPROO CLE GLND OR RMOURED CLE 8.2 PRESSCVI STGNI PER CVO RMTO
More informationHow can a charging station for electric vehicles be set up simply and safely?
SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,
More informationGirofari e lampeggianti
I4 Girofari e lampeggianti Revolving Warning Beacons CATALOGO TECNICO TECHNICAL CATALOGUE SERIE ONE CRIPTO ONE GIROFARI ARANCIO COMPLETI DI LAMPADA REVOLVING WARNING-LAMP SUPER WITH BULB Omologato secondo
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More informationENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationSPECIFICA MATERIALE N. 571020. RESISTORE DI POTENZA AVVOLTO SU TELAIO METALLICO Mod. RDP600 POWER RESISTOR WOUND ON METALLIC FRAME 220 ±2 200-1+5
N. 571 SPECIFICA MATERIALE Mod. RDP6 spessore 3 mm Approval Walter Cerutti Verified Mauro Pellegatta Revision 2 22/1/4 Emission DT 28.3.1997 Mod. RDP6 2 ±2-1+5 6 ±,3 8 ±,2 11 ±2 155 ±2 28 15 1. Potenza
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationBRUSHLESS DRIVE. CD1-k drive. LBD drive
BRUSHLESS DRIVE CD1-k drive LBD drive 31 CD1-k drive Caratteristiche hardware Alimentazione potenza: trifase 400-480Vac (+10/-15%) Alimentazione logica: 24 Vdc Corrente di picco: 2.7-7.2-14-30-45-70-90A
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationCatalogue May 2015. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole
Catalogue May 2015 EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Contents Introduction 1 Overview 1-pole 2 Overview 2-pole 3 Overview 3-pole 4 Overview 4-pole 5 Electronic Fuse Monitoring 6 Busbar
More informationFUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue 2011-2012 SOCOMEC. Fuse combination switches
FUSERBLOC Fuse combination switches appli_8_a fuser_548_a cat fuser_59_a cat fuser_52_a cat 2 to 25 A Manual operation Function FUSERBLOC are manually operated multipolar fuse combination switches. They
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationHTM PUMPS PP-PVDF Non-metallic mag drive centrifugal pumps
HTM S PP-PVDF Non-metallic mag drive centrifugal pumps POMPE HTM PP-PVDF Pompe centrifughe in materiale termoplastico FEATURES: Materials in contact with the liquid: Casing and impeller: PP/PVDF; O-ring:
More informationELENCO PROVE ACCREDITATE - CATEGORIA: 0
Scheda 1 di 8 ELENCO PROVE ACCREDITATE - CATEGORIA: 0 Concentrator photovoltaic (CPV) modules and assemblies 10.1 Ispezione visiva / Visual inspection IEC62108:2007 10.1 + CEI IEC 61215:2005 10.1 10.10
More informationMODULI INTERFACCIA A RELÈ ELETTROMECCANICI ELECTROMECHANICAL RELAY INTERFACE MODULES
MODULI INTERFACCIA A RELÈ ELETTROMECCANICI ELECTROMECHANICAL RELAY INTERFACE MODULES SERIE RM A UN CONTATTO IN SCAMBIO pag. 3 ONE EXCHANGE CONTACT RM SERIES pag. 3 SERIE RM A UN CONTATTO SCAMBIO CON CONNETTORE
More informationMOTORI CORRENTE CONTINUA (Ferrite) DC SERVOMOTORS (Ferrite)
D.C. MOTORS MOTORI CORRENTE CONTINUA (Ferrite) DC SERVOMOTORS (Ferrite) RAW D.C. MOTORS Indice - Index Specifiche Tecniche Standard 4 Characteristics of Standard Models Motore Serie 7 P 5 Motor Series
More informationGeneral-purpose Relay
General-purpose Relay An Improved Miniature Power Relay with Many Models for Sequence Control and Power Applications A wide range of relay variations including ones with operation indicators, high-capacity
More informationSwitching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches
Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation
More information