Catalog. Modular DIN rail components Installation contactors

Size: px
Start display at page:

Download "Catalog. Modular DIN rail components Installation contactors"

Transcription

1 Catalog Modular DIN rail components Installation contactors

2 0 CDC00C00

3 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation contactors with manual switch EN0 EN 9 EN0 0 Technical data Lamp load table Main accessories Ordering details CDC00C00

4 Installation contactors Benefits and features Introduction ABB offers a complete range of equipment for controlling, remote switching and protecting electrical installations in buildings as hotels, hospitals, shopping centers, office centers and domestic applications. ESB and EN installation contactors are designed to match the Modular DIN rail components (MDRC) for common use in dedicated panels providing high safety and finger protection. The range The ESB range includes ratings from 0 A to A with to -pole version. The EN contactor range offers types from 0 A to 0 A with an additional manual switch in front. Flexible use for many application ESB0 ESB can be used for DIN rail as well as for industrial applications: Resistive loads such as electric heaters, water heaters, etc Motors, pumps Lamp switching and controls (building installation) High comfort due to hum-free operation The installation contactor types ESB... ESB / EN... EN0 operate free from vibration, thanks to their DC coil technology. This feature has high value in building installations where hum-free and silent operations are important for people s farewell. High protection against overvoltages and current peaks Built-in surge protection for ESB... ESB ABB tested lamp table provides secure planning Approvals available Certificates for CE, CCC, UL/CSA, GOST, as well as household or ship approvals available. Other approvals on request. Compact and optimized design Installation contactors with MDRC design have a very compact size. A powerful ESB, max. operating current A fits in a small enclosure with only 0 mm depth. Cost savings Low power consumption of DC coils (ESB, ESB0, ESB) Better logistics, because AC/DC coil supply requires less variants Significantly reduced space compared to industrial contactors High availability and safety of EN types EN types have the same features and benefits as ESB contactors, but also have a special hand operating function. This provides customers with the following features: Manual control in case of failure is always available Easier and faster commissioning Time savings on maintenance and testing of equipment CDC00C00

5 Installation contactors Overview Remote controlled ESB0 ESB ESB0 ESB Remote and manually controlled EN0 EN EN0 - Width in number of modular spacings Coil types AC operated AC / DC operated AC / DC operated AC / DC operated Rated operational voltage Ue 0 V AC 0 V DC, 00 V AC 0 V DC, 00 V AC 0 V DC, 00 V AC AC- / AC-7a utilization category for air temperature near the contactor C Rated operational current Ie AC- / AC-7a 0 A A 0 A A Rated operational power AC- 0 V - phase kw. kw. kw. kw AC- / AC-7b utilization category for air temperature close to contactor C 00 V - phases - kw kw kw Rated operational current Ie AC- / AC-7b 0 V - phase 9 A 9 A A 0 A 00 V - phases - 9 A A 0 A Rated operational power AC- 0 V - phase. kw. kw. kw kw Accessories 00 V - phases - kw kw kw Auxiliary contact blocks NO - EH0-0 NO + NC - EH0- Distant piece - ESB-DIS Covers - ESB-PLK ESB-SPK ESB-PLK0/ ESB-SPK0/ CDC00C00

6 ESB0 installation contactors 0 A AC- / AC-7a AC operated Description The ESB0 installation contactors are used for the control of single phase loads up to 0 A. They operate with an AC coil. Various N.O. and N.C. contacts combinations are available. ESB0 SBC0007F00 Type Order code Pkg Ordering details Main contacts Width in Rated control Weight number of circuit voltage ) qty ( pc) modular spacings 0 Hz 0 Hz V V pcs kg ESB0-0 V 0Hz / V 0Hz GHE0R ESB0-0 V 0Hz / V 0Hz GHE0R ESB0-0 0V 0Hz / GHE0R V 0Hz 0 ESB0-0 0V 0Hz / V 0Hz GHE0R R R ESB0-0 V 0Hz / V 0Hz GHE0R ESB0-0 V 0Hz / V 0Hz GHE0R R R 0... ESB0-0 0V 0Hz / GHE0R V 0Hz 0 ESB0-0 0V 0Hz / V 0Hz GHE0R R ESB0- V 0Hz / V 0Hz GHE0R ESB0- V 0Hz / V 0Hz GHE0R R 0... ESB0-0V 0Hz / GHE0R V 0Hz 0 ESB0-0V 0Hz / V 0Hz GHE0R ) Other control voltages see voltage code table. The below tables indicate the available coil voltages and corresponding digits for order codes. When placing an order, please give the order code. Select a standard contactor from ordering details. Change the coil voltage code in the order code according to the table below. Example: ESB0-0 and coil 0 V 0 Hz, the order code is GHE0R00 Type Main dimensions mm, inches mm." EN/IEC 07 Auxiliary contacts N.O. N.C. ESB N.O. N.C. Main contacts Contactor type ESB AC operated EN AC operated.".77" Order code GHE0R 00." " AC coil code 0 Hz 0 Hz V V 0 V V 0 V V 9 V V 0 V V 0 V V 9 V 0 V 7 00 V 0 V 0 0 V... 7 V V 0 V 90 V 0 V 0 0 V 0 V 0 0 V V 0 0 V 7 V 0 V 0 V V 0." For EN0: only coil 0... and 0... are available.. 0.7"..7" ESB0 CDC00F00 CDC00C00

7 ESB installation contactors A AC- / AC-7a AC / DC operated Description The ESB installation contactors are used for the control of single and three-phases loads up to A. Due to their DC solenoid actuator, the ESB can be connected to AC or DC voltages. This provides the following benefits: Hum-free operation, low power consumption, integrated high overvoltage protection. Various N.O. and N.C. contacts combinations available. Main accessories: Auxiliary contact blocks EH0. ESB CDC00F000 Ordering details Main contacts R R R R R R R R R R R R R R R R 7 R7 R 7 7 R7 R () () Width in number of modular spacings Main dimensions mm, inches." Rated control circuit voltage Type Order code Pkg qty Weight ( pc) V AC/DC pcs kg ESB-0-AC/DC GHE90R00 0. ESB-0-AC/DC GHE90R ESB-0-AC/DC GHE90R ESB-0-AC/DC GHE90R ESB-0-0AC/DC GHE90R ESB-0-0AC/DC GHE90R ESB-0-00AC/DC GHE90R ESB-0-AC/DC GHE90R00 0. ESB-0-AC/DC GHE90R ESB-0-AC/DC GHE90R ESB-0-AC/DC GHE90R ESB-0-0AC/DC GHE90R ESB-0-0AC/DC GHE90R ESB-0-00AC/DC GHE90R ESB--AC/DC GHE90R00 0. ESB--AC/DC GHE90R ESB--AC/DC GHE90R ESB--AC/DC GHE90R ESB--0AC/DC GHE90R ESB--0AC/DC GHE90R ESB--00AC/DC GHE90R ESB--AC/DC GHE90R00 0. ESB--AC/DC GHE90R ESB--AC/DC GHE90R ESB--AC/DC GHE90R ESB--0AC/DC GHE90R ESB--0AC/DC GHE90R ESB--00AC/DC GHE90R ESB--AC/DC GHE970R00 0. ESB--AC/DC GHE970R ESB--AC/DC GHE970R ESB--AC/DC GHE970R ESB--0AC/DC GHE970R ESB--0AC/DC GHE970R ESB--00AC/DC GHE970R " mm." EN/IEC 07 0.".77".".. 0.7"..7" ESB CDC00F00 CDC00C00

8 ESB0 installation contactors 0 A AC- / AC-7a AC / DC operated Description The ESB0 installation contactors are used for the control of single and three-phases loads up to 0 A. Due to their DC solenoid actuator, the ESB0 can be connected to AC or DC voltages. This provides the following benefits: Hum-free operating system, no vibration, silent in operation, low power consumption, integrated high overvoltage protection. You can choose between a various N.O. and N.C. contacts combinations. Main accessories: Auxiliary contact blocks EH0. ESB0 CDC00F000 Ordering details Main contacts 7 () () R R 7 Width in number of modular spacings Rated control circuit voltage Type Order code Pkg qty Weight ( pc) V AC/DC pcs kg ESB0-0-AC/DC GHE90R ESB0-0-AC/DC GHE90R ESB0-0-AC/DC GHE90R ESB0-0-AC/DC GHE90R ESB0-0-0AC/DC GHE90R ESB0-0-0AC/DC GHE90R ESB0-0-00AC/DC GHE90R ESB0-0-AC/DC GHE90R ESB0--AC/DC GHE90R ESB0--0AC/DC GHE90R R R R 7 ESB0--AC/DC GHE90R ESB0--0AC/DC GHE90R R ESB0-0-AC/DC GHE90R ESB0-0-0AC/DC GHE90R ESB0-0-00AC/DC GHE90R ESB0-0-AC/DC GHE90R ESB0-0-0AC/DC GHE90R Main dimensions mm, inches."." mm." EN/IEC 07 0.".77".".. 0.7"..7" ESB0 CDC00F00 CDC00C00

9 ESB installation contactors A AC- / AC-7a AC / DC operated Description The ESB installation contactors are used for the control of single and three-phases loads up to A. Due to their DC solenoid actuator, the ESB can be connected to AC or DC voltages. This provides the following benefits: Hum-free operating system, no vibration, silent in operation, low power consumption, integrated high overvoltage protection. You can choose between a various N.O. and N.C. contacts combinations. Main accessories: Auxiliary contact blocks EH0. ESB CDC00F000 Ordering details Main contacts 7 () () R R 7 Width in number of modular spacings Rated control circuit voltage Type Order code Pkg qty Weight ( pc) V AC/DC pcs kg ESB-0-AC/DC GHE90R ESB-0-AC/DC GHE90R ESB-0-AC/DC GHE90R ESB-0-AC/DC GHE90R ESB-0-0AC/DC GHE90R ESB-0-0AC/DC GHE90R ESB-0-00AC/DC GHE90R ESB-0-AC/DC GHE90R ESB--00AC/DC GHE90R R R R 7 0 ESB--0AC/DC GHE90R ESB--0AC/DC GHE90R R 0 ESB-0-0AC/DC GHE90R ESB-0-00AC/DC GHE90R ESB-0-AC/DC GHE90R ESB-0-0AC/DC GHE90R R 0 ESB--0AC/DC GHE90R R Main dimensions mm, inches."." mm." EN/IEC 07 0.".77".".. 0.7"..7" ESB CDC00F00 CDC00C00 7

10 EN0 installation contactors - manually / automatic operated 0 A AC- / AC-7a AC operated EN0 SBC000F00 Description The EN0 installation contactors are used for the control of single phase loads up to 0 A. They operate with an AC coil and have a built-in toggle switch to select between three function modes. This offers many advantages as: You can make functionnal test before installation start-up. It can be used for maintenance operation, to change lamps and test it. It provides higher safety and drop out as you can switch the application manually. The toggle switch is also used for household application like water heating where double rate of kwh is used. Function modes: OFF position, automatic run (normal contactor function), manual override with a return to AUTO the next time the coil is energized. Ordering details Main contacts Width in number of modular spacings Rated control circuit voltage Type Order code Pkg qty Weight ( pc) 0 Hz 0 Hz V V pcs kg EN0-0 V 0Hz / V 0Hz GHE0R EN0-0 0V 0Hz GHE0R Main dimensions mm, inches." " mm." EN/IEC 07.77" 0.".".. 0.7"..7" ESB0 CDC00F00 CDC00C00

11 EN installation contactors - manually / automatic operated A AC- / AC-7a AC / DC operated EN CDC00F000 Description The EN installation contactors are used for the control of single phase loads up to A. They operate with an AC coil and have a built-in toggle switch to select between three function modes. This offers many advantages as: You can make functionnal test before installation start-up. It can be used for maintenance operation, to change lamps and test it. It provides higher safety and drop out as you can switch the application manually. The toggle switch is also used for household application like water heating where double rate of kwh is used. Function modes: OFF position, automatic run (normal contactor function), manual override with a return to AUTO the next time the coil is energized. Ordering details Main contacts 7 () Width in number of modular spacings Rated control circuit voltage Type Order code Pkg qty Weight ( pc) V AC/DC pcs kg EN-0-AC/DC GHE0R EN-0-0AC/DC GHE0R () R 7 EN--AC/DC GHE0R EN--0AC/DC GHE0R R 0 EN-0-0AC/DC GHE0R Main dimensions mm, inches."." mm." EN/IEC " 0.".". 0.7"..7" ESB CDC00F00 CDC00C00 9

12 EN0 installation contactors 0 A AC- / AC-7a AC / DC operated EN0 CDC00F000 Description The EN0 installation contactors are used for the control of single phase loads up to 0 A. They operate with an AC coil and have a built-in toggle switch to select between three function modes. This offers many advantages as: You can make functionnal test before installation start-up. It can be used for maintenance operation, to change lamps and test it. It provides higher safety and drop out as you can switch the application manually. The toggle switch is also used for household application like water heating where double rate of kwh is used. Function modes: OFF position, automatic run (normal contactor function), manual override with a return to AUTO the next time the coil is energized. Ordering details Main contacts R 7 7 () () Width in number of modular spacings Rated control circuit voltage Type Order code Pkg qty Weight ( pc) V AC/DC pcs kg EN0-0-AC/DC GHE0R EN0-0-0AC/DC GHE0R EN0-0-0AC/DC GHE0R EN0--AC/DC GHE0R EN0--0AC/DC GHE0R R 0 EN0-0-0AC/DC GHE0R EN0-0-0AC/DC GHE0R Main dimensions mm, inches."." mm." EN/IEC " 0.".". 0.7"..7" EN0 CDC00F00 0 CDC00C00

13 Installation contactors Technical data Main circuit Utilization characteristics according to IEC/EN Contactor type ESB0 / EN0 ESB / EN ESB0 / EN0 ESB Standards IEC/EN 097- IEC/EN IEC/EN 09 IEC/EN 097- IEC/EN IEC/EN IEC/EN 09 Rated operational voltage U e 0 V AC 0 V DC 00 V AC 0 V DC 00 V AC 0 V DC 00 V AC Rated frequency 0 / 0 Hz 0 / 0 Hz 0 / 0 Hz 0 / 0 Hz AC- / AC-7a utilization category for air temperature near the contactor C Rated operational current I e AC- / AC-7a 0 A A 0 A A Rated operational power AC- 0 V - phase kw. kw. kw. kw 00 V - phases - kw kw kw AC- / AC-7b utilization category for air temperature close to contactor C Rated operational current I e AC- / AC-7b 0 V - phase 9 A 9 A A 0 A 00 V - phases - 9 A A 0 A Rated operational power AC- 0 V - phase. kw. kw. kw kw 00 V - phases - kw kw kw Rated making capacity AC- acc. to IEC x I e / AC- 0 x I e / AC- 0 x I e / AC- 0 x I e / AC- Rated breaking capacity AC- acc. to IEC x I e / AC- x I e / AC- x I e / AC- x I e / AC- Short-circuit protective devices gg type fuses 0 A A A 0 A Rated short-time withstand current I CW at 0 C ambient 7 A 7 A 7 A 0 A temp. in free air, from a cold state 0 s Power loss per pole W W W W Maximum electrical switching frequency AC- / AC-7a 00 cycles per hour 00 cycles per hour 00 cycles per hour 00 cycles per hour AC- / AC-7b 00 cycles per hour 00 cycles per hour 00 cycles per hour 00 cycles per hour Electrical durability AC- / AC-7a 0000 cycle 0000 cycle 0000 cycle 0000 cycle AC- / AC-7b 0000 cycle cycle cycle 0000 cycle Mechanical durability cycle cycle cycle cycle Main circuit Utilization characteristics according to UL/CSA Contactor type ESB0 ESB ESB0 ESB Standards UL 097-, UL General use rating 0 V 0 A A 0 A A Motor rating Full load current V - phase A 9. A A A V - phases - 7. A A A Horse power rating V - phase hp hp 7. hp 0 hp V - phases - hp hp hp Short-circuit protection for contactors without thermal O/L relay - Motor protection excluded Fuse rating A A 0 A 7 A Fuse type 0 V - K K K Max. electrical switching frequency for general use 00 cycles/h 00 cycles/h 00 cycles/h 00 cycles/h for motor use 00 cycles/h 00 cycles/h 00 cycles/h 00 cycles/h CDC00C00

14 Installation contactors Technical data General technical data Contactor type ESB0 / EN0 ESB / EN ESB0 / EN0 ESB Rated insulation voltage U i acc. to IEC V 00 V 00 V 00 V and VDE 00 (Gr. C) acc. to UL/CSA 0 V 00 V 00 V 00 V Rated impulse withstand voltage U imp kv kv kv kv Ambient air temperature operation C C C C storage C C C C Maximum operating altitude permissible 000 m 000 m 000 m 000 m Resistance to shock acc. to IEC m/s² ( ms pulse) 0 m/s² ( ms pulse) 0 m/s² ( ms pulse) 0 m/s² ( ms pulse) Magnet system characteristics Contactor type ESB0 / EN0 ESB / EN ESB0 / EN0 ESB Coil operating limits acc. to IEC/EN x U c (at θ C) x U c (at θ C) x U c (at θ C) x U c (at θ C) Drop-out voltage in % of U c approximate Rated frequency 0 / 0 Hz DC, 0 / 0 / 00 Hz DC, 0 / 0 / 00 Hz DC, 0 / 0 / 00 Hz Frequency range 0 / 0 Hz Hz Hz Hz Coil consumption average holding value 0 Hz. VA VA VA. VA average pull-in value 0 Hz VA VA VA VA Mounting characteristics and conditions for use Contactor type ESB0 / EN0 ESB / EN ESB0 / EN0 ESB Mounting position position to position to Pos Pos. Pos. Pos. Pos.,,, ± 0 Pos. Mounting on DIN rail TH- ( x mm Mounting Rail) acc. to IEC 07 TH-7. ( x 7. mm Mounting Rail) acc. to IEC 07 Connecting characteristics Main circuit Contactor type ESB0 EN0 ESB EN ESB0 EN0 ESB Connecting capacity Rigid x 0 mm² mm² mm².... mm².... mm² mm².... mm² mm² x Flexible with ferrule x mm² mm².... mm².... mm² x mm² Flexible with insulated ferrule x mm² mm².... mm².... mm² x mm² Flexible x mm² mm².... mm².... mm² x mm² Stranded acc. to UL/CSA AWG - - AWG - - AWG - - AWG - Flexible acc. to UL/CSA AWG - - AWG - - AWG - - AWG - Degree of protection IP 0 IP 0 IP 0 IP 0 Wire stripping length 7 mm 0 mm mm mm Tightening torque. Nm Nm. Nm. Nm Recommended screw driver Pozidriv Pozidriv Pozidriv Pozidriv Control circuit Contactor type ESB0 EN0 ESB EN ESB0 EN0 ESB Connecting capacity Rigid x mm² mm² mm² mm² x mm² Degree of protection (all terminals) IP 0 IP 0 IP 0 IP 0 IP 0 IP 0 IP 0 Stripping length 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm Tightening torque. Nm. Nm 0.9 Nm 0.9 Nm 0.9 Nm 0.9 Nm 0.9 Nm Recommended screw driver Pozidriv Pozidriv Pozidriv Pozidriv Pozidriv Pozidriv Pozidriv CDC00C00

15 Installation contactors Technical data DC switching table DC- (L/R ms) DC- (L/R ms) Contactor type Rated operational voltage U e pole poles in series poles in series pole poles in series poles in series ESB0 V DC NO contacts V DC NO contacts V DC NO contacts V DC NO contacts V DC NO contacts ESB V DC NO contacts V DC NO contacts V DC NO contacts V DC NO contacts V DC NO contacts ESB0 V DC NO contacts V DC NO contacts V DC NO contacts V DC NO contacts V DC NO contacts ESB V DC NO contacts V DC NO contacts V DC NO contacts V DC NO contacts V DC NO contacts DC- (L/R ms) DC- (L/R ms) Contactor type Rated operational voltage U e pole poles in series poles in series pole poles in series poles in series ESB0 V DC NC contacts V DC NC contacts V DC NC contacts V DC NC contacts V DC NC contacts ESB V DC NC contacts V DC NC contacts V DC NC contacts V DC NC contacts V DC NC contacts CDC00C00

16 Installation contactors Lamp load table Lamp load Please notice: Switching lamps is a capacitor load application where high inrush current peaks could occur. These are influenced by the length and cross section of the wire as well as the type of power supply unit and specifications of the lamp brand. For example long cables can increase the possible number of lamps per pole. The table shows the allowed max. current for pole and considers already the startup current peaks. The following selection table shows the current values and the maximum switchable capacitor load for compensated lamps. These two limits have to be considered in the selection of contactors. Contactor type ESB0/EN0 ESB/EN ESB0/EN0 ESB Permitted compensating capacity per phase C max 7 μf 00 μf 0 μf 00 μf Lamp types Maximum load of the current paths during switching of electric lamps I e (A) Incandescent and halogen lamps (0 V) Mixing lamps without ballast Fluorescent lamps with conventional ballast single lamp uncompensated 9 single lamp parallel compensated. 0 series compensation, duo circuit 9 Fluorescent lamps with electronic ballast or CFL LED lamps ) High pressure mercury-vapor lamps single lamp without compensation 9 single lamp with parallel compensation. 0 Halogen metal-vapor lamps single lamp without compensation 9 single lamp with parallel compensation. 0 High pressure sodium-vapor lamps single lamp without compensation 9 single lamp with parallel compensation. 0 Low pressure sodium-vapor lamps single lamp without compensation 9 single lamp with parallel compensation. 0 Electronic ballast devices ) Valid for max. inrush of 0 x I e Example for lamp load calculation Due to many varieties of lamps and ballasts we advice to take the current load as base for reference. The lamp table considers already the inrush peaks and other lamp parameters. Please see the following examples for a reliable project lamp calculation Fluorescent lamp with conventional ballast, uncompensated the lamp operating current I =. A, voltage U = 0 V pole of ESB can be loaded with max. A, see lamp table => A /. A =. => lamps pole of ESB0 can be loaded with max. 9 A, see lamp table => 9 A /. A = lamps Please use the referring value in the table stated above and divide it with the current stated on the lamp. This will lead into the number of lamps which can be switched. E.g.: ESB used for LED lamps: 7 A (= 7000 ma) / ma =. => lamps CDC00C00

17 ESB/EN installation contactors Main accessories EH0-0 CDC00F00 Ordering details Suitable for Auxiliary contacts Type Order code Pkg qty Auxiliary contact blocks ESB, ESB0, ESB EN, EN0 pcs Weight ( pc) EH0-0 GHE0R EH0- GHE0R kg ESB-PLK ESB-SPK0/ ESB-DIS SST9 CDC00F00 SST09 Suitable for Description Type Order code Pkg qty pcs Weight ( pc) kg Sealing covers ESB, EN sealing cover ESB-PLK GHE090R ESB0, ESB, EN0 sealing cover ESB-PLK0/ GHE090R ESB, EN protection cover ESB-SPK GHE090R ESB0, ESB, EN0 protection cover ESB-SPK0/ GHE090R Distant piece ESB, ESB0, ESB, EN, EN0 ESB-DIS GHE090R Labels ) ESB0, ESB, ESB0, ESB, EN0, EN, EN0 unlabelled ) SZ-KZS GHS09R numbering -0 SZ-KZS/ GHS09R numbering x -0 SZ-KZS/ GHS09R numbering x -0 SZ-KZS/9 GHS09R numbering x -0 SZ-KZS/0 GHS09R labelled L SZ-KZS/ GHS09R labelled L SZ-KZS/ GHS09R labelled L SZ-KZS/ GHS09R ) Special labels on request: minimum quantities 0 ) The unlabelled can be labelled by water-resistant and permanent marker or by means of computer-controlled labelling system (plotter). SZ-KZS SK00Z9 EH0 auxiliary contact block Utilization characteristics according to IEC/EN Type EH0 Rated operational voltage U e 00 V Conventional free air thermal current I th Rated frequency 0/0 Hz Rated operational current I e / AC- V 0/0 Hz A 0 V 0/0 Hz A V 0/0 Hz A 00 V 0/0 Hz A Rated operational current DC- V 0. A 0 V 0.7 A Rated making capacity AC- 0 x I e / AC- Rated breaking capacity AC- x I e / AC- Short-circuit protective devices gg Type Fuses 0 A Minimum switching capacity >7 V / > ma EH0 not applicable for EN0 and ESB0. CDC00C00

18 Contact us ABB STOTZ-KONTAKT GmbH Eppelheimer Straße D-9 Heidelberg, Germany ABB France Low Voltage Products Division, rue Jean Perrin F-97 Chassieu cedex / France You can find the address of your local sales organisation on the ABB home page Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 0 ABB All rights reserved Order Number CDC 0 0 C00 Printed in Germany (0/)

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011 Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

ESB and EN installation contactors Application handbook

ESB and EN installation contactors Application handbook ESB and EN installation contactors Application handbook 2 2CDC103022M0201 Content 1 Basic function of installation contactors 4 2 Modular DIN rail components 5 3 ESB/EN Installation contactors 6 4 Technical

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuators SA/S Product Information ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuators SA/S Product Information ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

System pro M compact Miniature Circuit Breaker S 200/S 200 M

System pro M compact Miniature Circuit Breaker S 200/S 200 M Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M 2CDC021023S0012 2CDC021038S0012 The miniature circuit breakers of the System pro M compact series S 200 and S 200 M provide state-of-the-art

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA Miniature Circuit Breaker SU 200 M The next generation MCB for UL/CSA applications within

More information

Panorama. Motor protection and control Manual motor starters, contactors and overload relays

Panorama. Motor protection and control Manual motor starters, contactors and overload relays Panorama Motor protection and control Manual motor starters, contactors and overload relays ABB sets a new standard in motor control and power switching Featuring AF technology as standard, the latest

More information

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied

More information

Low Voltage Products. Switches Automatic Transfer Switches

Low Voltage Products. Switches Automatic Transfer Switches Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43 Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43 The three-phase monitoring relay CM-MPS.43 monitors the phase parameters phase sequence, phase failure, over- and undervoltage

More information

Siemens AG 2011. Switching Devices. Configuration Manual 10/2010 SENTRON. Answers for infrastructure.

Siemens AG 2011. Switching Devices. Configuration Manual 10/2010 SENTRON. Answers for infrastructure. Siemens AG 20 Switching Devices Configuration Manual 0/200 SETRO Answers for infrastructure. Siemens AG 20 Siemens AG 20 Switching Devices 4 Introduction 7 Control switches, 5TE8 9 Pushbuttons, 5TE4 Light

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

ZS25 Screw Clamp Terminal Blocks Feed-through

ZS25 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

13 SERIES. Electronic step relays 10-16 A 13.81 13.91

13 SERIES. Electronic step relays 10-16 A 13.81 13.91 13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

Feed-through terminal block - SSK 110 KER-EX - 0502058

Feed-through terminal block - SSK 110 KER-EX - 0502058 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

MNS is Switchgear System Technical Overview

MNS is Switchgear System Technical Overview Switchgear System Technical Overview Innovative Design ABB s innovative MNS is concept combines the long term experience, energy efficiency, grid reliability and industrial productivity of the well-known

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Contact expansion modules

Contact expansion modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts

More information

Contact expander modules

Contact expander modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:

More information