Technical catalogue. Modular DIN rail components Installation contactors
|
|
- Amberlynn Williams
- 7 years ago
- Views:
Transcription
1 Technical catalogue Modular DIN rail components Installation contactors
2
3 Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB A / AC-/AC-7a ESB A / AC-/AC-7a ESB A / AC-/AC-7a ESB Main Technical Data...8 Lighting application...3 EN Installation Contactors - Manually/Automatic Operated 0 A / AC-/AC-7a EN A / AC-/AC-7a EN A / AC-/AC-7a EN Main Technical Data...7 ESB/EN Installation Contactors Main Accessories...9 Index...0 SBC030S00 ABB
4 Modular DIN rail components Installation Contactors ESB and EN All over the world, commercial and industrial buildings such as hospitals, hotels, shopping and sport centers, domestic and residential installation are equipped with ABB low voltage products and systems. From switchboard to light switch, ABB covers the complete range of equipment required for controlling and protecting electrical installations. Typical segments - Residential installations 3 Hotels 3 ABB
5 For controlling and remote switching, ABB offers a complete range of installation contactors that are mainly used in the following applications: Lighting Heating Ventilation Pumps and motors. ESB and EN installation contactors are designed to match the Modular DIN rail components for common use in dedicated panels. The ESB range includes 4 ratings from 0 A to 63 A with to 4-pole version. The EN range includes 3 ratings from 0 A to 40 A. Many contacts variations are available for managing all application. Products comply with standards IEC and IEC6095. Construction: The ESB0, EN0 operates with an AC solenoid system. Types ESB4...63, EN are fitted with a DC solenoid actuator and are therefore hum-free. The noise during switching is barely audible making it beneficial for use in buildings such as hospitals, hotels or houses. An incorporated varistor protects the coil against remote lightning strikes and overvoltages up to 5 kv. In addition, it limits the interference voltage peaks of the solenoid system. The contactors can therefore be combined with programmable logic controllers. There is no need for a protective circuit. The solenoid system is provided with radio interference suppression. Accessories are available, such as auxiliary contacts and sealing covers. ESB advantages: Powerful for lamp switching Operation flag indicator DC coil: - Noiseless and hum free - Low power consumption - Integrated overvoltage protection. The EN contactors have a built-in toggle switch for automatic and manual operation. EN advantages: Facilitate commissioning Functional test before start-up Ease maintenance operation High degree of safety and availability in case of automation system failure. 4 Shopping centers 5 Hospitals 6 Commercial & industrial buildings ABB 3
6 0 A AC-/AC-7a ESB0 Installation Contactors AC Operated Application The ESB contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and can be integrated easily in dedicated panels. Certifications and Approvals UL CSA CCC RMRS BV CE Description The ESB0 contactors are used for the control of single phase loads up to 0 A. They operate with an AC coil. You can choose between a various N.O. and N.C. contacts combination. Ordering Details Main poles Nb of Control coil voltage Type Order code Pack (ing) Weight modules 50 Hz 60 Hz pieces kg ( pce) V 4 V ESB0-0 GHE30R V 4 V GHE30R V 8 V GHE30R A 4 4 V 48 V GHE30R N.O. 48 V 55 V GHE30R V V GHE30R V 64 V GHE30R V 78 V GHE30R V - GHE30R V 4 V ESB0-0 GHE30R R R3 0 V 4 V GHE30R V 8 V GHE30R A R R4 4 V 48 V GHE30R N.C. 48 V 55 V GHE30R V V GHE30R V 64 V GHE30R V 78 V GHE30R V - GHE30R V 4 V ESB0- GHE330R R3 0 V 4 V GHE330R V 8 V GHE330R A R4 4 V 48 V GHE330R N.O. 48 V 55 V GHE330R N.C. 0 V V GHE330R V 64 V GHE330R V 78 V GHE330R V - GHE330R Mounting positions Pos Main Technical Data For complete technical data see SBC03005S00.pdf Main poles Rated operational voltage U e 50 V acc to. IEC and IEC 6095 I e AC- / AC-7a Rated operational current (for air temperature close to contactor θ 55 C) 0 A AC-3 / AC-7b Ratings (for air temperature close to contactor θ 55 C) Rated operational power phase 30 V. kw I e Rated operational current phase 30 V 9 A Magnet system Coil operating limits (acc. to IEC ) U c (at θ 55 C) Average pull-in coil consumption value 8 VA / 5 W Average holding coil consumption value 3. VA /. W Connecting capacity Main pole terminals Rigid x.5 0 mm x.5 4 mm Coil terminals Rigid x mm x mm Pos. 4 Pos " " Pos. Pos., 3, 4, ± mm EN/IEC " ". 0.43" " " Dimensions: mm, inches SBC0300S00 4 ABB
7 4 A AC-/AC-7a ESB4 Installation Contactors AC / DC Operated Application The ESB contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and can be integrated easily in dedicated panels. Certifications and Approvals UL CSA CCC RMRS BV GL LRS DNV CE Description The ESB4 contactors are used for the control of single and three-phases loads up to 4 A. Due to their DC solenoid actuator, the ESB4 can be connected to AC or DC voltages. This provides the following benefits: Hum-free operating system, no vibration, silent in operation, low power consumption, integrated high overvoltage protection 5 kv. You can choose between a various N.O. and N.C. contacts combination. Main accessories: Auxiliary contact blocks EH04. Mounting positions Pos Ordering Details Main poles Nb of Control coil voltage Type Order code Pack (ing) Weight modules Hz DC pieces kg ( pce) V V ESB4-40 GHE390R V 4 V GHE390R V 4 V GHE390R A 48 V 48 V GHE390R N.O V V GHE390R V V GHE390R A R R R3 R4 R5 R6 R7 R8 59.3" V V GHE390R V V ESB4-04 GHE390R V 4 V GHE390R V 4 V GHE390R V 48 V GHE390R N.C V V GHE390R V V GHE390R V V GHE390R A R3 R4 R5 R6 7 8 V V ESB4- GHE3930R V 4 V GHE3930R V 4 V GHE3930R V 48 V GHE3930R N.O V V GHE3930R N.C V V GHE3930R V V GHE3930R A R3 R V V ESB4-3 GHE3960R V 4 V GHE3960R V 4 V GHE3960R V 48 V GHE3960R N.O V V GHE3960R N.C V V GHE3960R V V GHE3960R A R R 3 4 R5 R6 R7 R8 V V ESB4-3 GHE3970R V 4 V GHE3970R V 4 V GHE3970R V 48 V GHE3970R N.O V V GHE3970R N.C V V GHE3970R V V GHE3970R Main Technical Data For complete technical data see SBC03005S00.pdf Main poles Rated operational voltage U e 400 V acc to. IEC and IEC 6095 I e AC- / AC-7a Rated operational current (for air temperature close to contactor θ 55 C) 4 A AC-3 / AC-7b Ratings (for air temperature close to contactor θ 55 C) Rated operational power 3 phases 400 V 4 kw I e Rated operational current 3 phases 400 V 9 A Magnet system Coil operating limits (acc. to IEC ) U c (at θ 55 C) Average pull-in coil consumption value 4 VA / 4 W Average holding coil consumption value 4 VA / 4 W Connecting capacity Main pole terminals Rigid x.5 0 mm x.5 4 mm Coil terminals Rigid x 4 mm x mm 36.4" Pos. 4 Pos. Pos. 3 Pos., 3, 4, ± mm EN/IEC " " Pos " " " Dimensions: mm, inches SBC0300S00 ABB 5
8 40 A AC-/AC-7a ESB40 Installation Contactors AC / DC Operated Application The ESB contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and can be integrated easily in dedicated panels. Description The ESB40 contactors are used for the control of single and three-phases loads up to 40 A. Due to their DC solenoid actuator, the ESB40 can be connected to AC or DC voltages. This provides the following benefits: Hum-free operating system, no vibration, silent in operation, low power consumption, integrated high overvoltage protection 5 kv. You can choose between a various N.O. and N.C. contacts combination. Main accessories: Auxiliary contact blocks EH04. Ordering Details Certifications and Approvals UL CSA CCC RMRS BV GL LRS DNV CE Main poles Nb of Control coil voltage Type Order code Pack (ing) Weight modules Hz DC pieces kg ( pce) 3 V V ESB40-40 GHE3490R V 4 V GHE3490R V 4 V GHE3490R V 48 V GHE3490R A N.O V V GHE3490R V V GHE3490R V V GHE3490R V 45 V GHE3490R V 4 V ESB40- GHE34930R R3 R V 30 V GHE34930R A R4 R6 8 N.O. N.C. R V 4 V ESB40-3 GHE34960R V 30 V GHE34960R A R N.O. N.C. A 3 N.O V 4 V ESB40-30 GHE34950R V 30 V GHE34950R V 400 V GHE34950R V 4 V ESB40-0 GHE34940R V 30 V GHE34940R A N.O. 4 Mounting positions Pos Main Technical Data For complete technical data see SBC03005S00.pdf Main poles Rated operational voltage U e 400 V acc to. IEC and IEC 6095 I e AC- / AC-7a Rated operational current (for air temperature close to contactor θ 55 C) 40 A AC-3 / AC-7b Ratings (for 500 r.p.m., 50 Hz or 800 r.p.m., 60 Hz, 3-phase motors) (for air temperature close to contactor θ 55 C) Rated operational power 3 phases 400 V kw I e Max. Rated operational current 3 phases 400 V A Magnet system Coil operating limits (acc. to IEC ) U c (at θ 55 C) Average pull-in coil consumption value 5 VA / 5 W Average holding coil consumption value 5 VA / 5 W Connecting capacity Main pole terminals Rigid x.5 5 mm x.5 0 mm Coil terminals Rigid x 4 mm x mm 59.3" 54.3" Pos. 4 Pos. 3 Pos. Pos., 3, 4, ± mm EN/IEC " " Pos " " " Dimensions: mm, inches SBC03003S00 6 ABB
9 63 A AC-/AC-7a ESB63 Installation Contactors AC / DC Operated Application The ESB contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and can be integrated easily in dedicated panels. Certifications and Approvals UL CSA CCC RMRS BV GL LRS DNV CE Description The ESB63 contactors are used for the control of single and three-phases loads up to 63 A. Due to their DC solenoid actuator, the ESB63 can be connected to AC or DC voltages. This provides the following benefits: Hum-free operating system, no vibration, silent in operation, low power consumption, integrated high overvoltage protection 5 kv. You can choose between a various N.O. and N.C. contacts combination. Main accessories: Auxiliary contact blocks EH04. Ordering Details Main poles Nb of Control coil voltage Type Order code Pack (ing) Weight modules Hz DC pieces kg ( pce) 3 V V ESB63-40 GHE3690R V 4 V GHE3690R V 4 V GHE3690R A 48 V 48 V GHE3690R N.O V V GHE3690R V V GHE3690R V V GHE3690R V 45 V GHE3690R V 400 V ESB63- GHE36930R R3 R5 7 A R4 R6 8 N.O. N.C. R3 5 7 A R N.O. N.C V 0 V ESB63-3 GHE36960R V 30 V GHE36960R V 30 V ESB63-30 GHE36950R V 400 V GHE36950R A 4 3 N.O. A N.O. 3 4 R V 4 V ESB63-0 GHE36940R V 30 V GHE36940R V 30 V ESB63- GHE36980R A R4 N.O. N.C. Mounting positions Pos Main Technical Data For complete technical data see SBC03005S00.pdf Main poles Rated operational voltage U e 400 V acc to. IEC and IEC 6095 I e AC- / AC-7a Rated operational current (for air temperature close to contactor θ 55 C) 63 A AC-3 / AC-7b Ratings (for 500 r.p.m., 50 Hz or 800 r.p.m., 60 Hz, 3-phase motors) (for air temperature close to contactor θ 55 C) Rated operational power 3 phases 400 V 5 kw I e Max. rated operational current 3 phases 400 V 30 A Magnet system Coil operating limits (acc. to IEC ) U c (at θ 55 C) Average pull-in coil consumption value 65 VA / 65 W Average holding coil consumption value 4. VA / 4. W Connecting capacity Main pole terminals Rigid x.5 5 mm x.5 0 mm Coil terminals Rigid x 4 mm x mm 59.3" 54.3" Pos. 4 Pos. 3 Pos. Pos., 3, 4, ± mm EN/IEC " " Pos " " " Dimensions: mm, inches SBC03004S00 ABB 7
10 ESB Installation Contactors Technical Data Main Pole - Utilization Characteristics according to IEC Contactor types: AC operated ESB0 AC / DC operated ESB4 ESB40 ESB63 Rated operational voltage U e max. V AC: 50, DC: 0 AC: 400, DC: 0 Rated frequency limits Hz 50/60, DC Utilization category AC- / AC-7a for air temperature close to contactor < 55 C Max. rated operational current I e AC- / AC-7a N.O. A N.C. A Utilization category AC-3 / AC-7b for air temperature close to contactor < 55 C Max. rated operational current I e AC-3/AC-7b 30 V - phase N.O. A V - 3 phases N.O. A Rated operational power AC-3 30 V - phase kw V - 3 phases kw Rated making capacity AC-3 0 x I e / AC-3 Rated breaking capacity AC-3 8 x I e / AC-3 Short-circuit protection for contactors gg type fuse A Rated short-time withstand current I cw at 40 C ambient temp., in free air, from a cold state 0 s A Heat dissipation per pole I e / AC-/AC-7a W Max. electrical switching frequency for AC- / AC-7a cycles/h 300 for AC-3 / AC-7b cycles/h 600 Electrical durability for AC- / AC-7a cycles for AC-3 / AC-7b cycles Mechanical durability millions of operating cycles U U U U Single-phase (AC-, AC-7a) Three-phase (AC-, AC-7a) L U L U L V M M L Single-phase (AC-7b) V L3 Three-phase (AC-7b, AC-3) W SBC03005S00 8 ABB
11 ESB Installation Contactors Technical Data Main Pole - Utilization Characteristics according to UL/CSA Contactor types: AC operated ESB0 AC / DC operated ESB4 ESB40 ESB63 General use rating Amp rating 40 V A V A Motor rating Amp rating 0 V - phase A V - phase N.O. A N.C. A V - 3 phases N.O. A N.C. A Motor power 0 V - phase hp / V - phase hp V - 3 phases hp Short-circuit protection for contactors without thermal O/L relay - Motor protection excluded Fuse rating, 480 V A 5 5 / K5 40 / K5 75 / K5 Fuse type, 600 V Max. electrical switching frequency for general use cycles/h 300 for motor use cycles/h 600 General Technical Data Rated insulation voltage U i according to IEC V according to UL/CSA V Rated impulse withstand voltage U imp kv 6 Standards IEC / EN and IEC 6095 / EN 6095, UL 508, CSA C. N 4-05 Air temperature close to contactor for operation at U c C (Type ESB4...63: for ambient temperature > 40 C, add ESB-DIS (/ module) at every second contactor) for storage C Climatic withstand IEC , UTE execution * Operating altitude m 000 Shock withstand 0 g / 4 ms / axes X Y Z Mounting positions Pos, 3, 4, ±30 Pos Pos 5 : not allowed for ESB0 Pos. 4 Pos. 3 Pos. Pos. /3/4/± 30 Fixing on rail acc. to IEC 6075 and EN x x 5 Pos. 5 * ESB0 only SBC03005S00 ABB 9
12 ESB Installation Contactors Technical Data Magnet System Characteristics Contactor types: AC operated ESB0 AC / DC operated ESB4 ESB40 ESB63 Rated operational voltage U e max. - at 50 Hz V at 60 Hz V at 400 Hz V DC V Coil operating limits acc. to IEC x U c (at θ 55 C) Drop-out voltage in % of U c approx % approx % Frequency range Hz 50/60 DC, Coil consumption Average pull-in value VA / W 8 / 5 4 / 4 5 / 5 65 / 65 Average holding value VA / W 3. /. 4 / 4 5 / 5 4. / 4. Operating time between coil energization and: N.O. contact closing ms 40 between coil de-energization and: N.O. contact opening ms 40 Connecting Characteristics Contactor types: AC operated ESB0 AC / DC operated ESB4 ESB40 ESB63 Connecting capacity (min.... max.) Main pole terminals Rigid x mm² x mm² Capacity acc. to UL/CSA AWG Coil terminals Rigid x mm² x mm² Capacity acc. to UL/CSA AWG Degree of protection acc. to IEC / EN and IEC 6059 / EN 6059 Protection against direct contact in acc. with EN 5074 All terminals IP0 Screwdriver type Main poles Flat Ø 5 / Pozidriv Flat Ø 7.5 / Pozidriv Coil terminals Flat Ø 5 / Pozidriv Flat Ø 5 / Pozidriv Stripping length Main poles mm 0 3 Coil terminals mm 7 Tightening torque Main poles Nm..5 Coil terminals Nm 0.9 SBC03005S00 0 ABB
13 ESB Installation Contactors Technical Data EH04... Auxiliary Contact Block - Utilization Characteristics according to IEC Contactor types: AC operated ESB0 AC / DC operated ESB4 ESB40 ESB63 Rated operational voltage U e max. V Conventional free air thermal current I th θ < 40 C A - 6 Rated frequency limits Hz - 50/60 Rated operational current I e / AC-5 acc. to IEC V 50/60 Hz A V 50/60 Hz A V 50/60 Hz A - Making capacity acc. to IEC x I e AC-5 Breaking capacity acc. to IEC x I e AC-5 Short-circuit protection gi type fuse A - 0 Minimum switching capacity with failure rate acc. to IEC V/mA - 7 / 5 Heat dissipation per pole at 6 A W - 0. Electrical durability AC- / 400 V / 3-phase for ESB Millions of operating cycles ESB0 ESB4 ESB40 ESB , Breaking current [A] AC-3 / 400 V / 3-phase for ESB Millions of operating cycles ESB4 ESB40 ESB Breaking current [A] Switching capacity [kw] SBC03005S00 ABB
14 ESB Installation Contactors Technical Data DC-/DC-3 switching DC with N.O. contacts (N.O.) Type DC- (L/R ms) Rated operating current path current paths voltage U e in series 3 current paths in series DC-3 (L/R ms) current path current paths in series ESB0-0 4 V DC 0 A 0 A - 5 A 0 A - 48 V DC 5 A 0 A - 7 A 5 A - 60 V DC 5 A 0 A - 5 A 0 A - 0 V DC 5 A 5 A -.5 A 5 A - 0 V DC 0.5 A 5 A - 0. A.5 A - ESB4 4 V DC 4.0 A 4.0 A 4.0 A 6.0 A 4.0 A 4.0 A 48 V DC.0 A 4.0 A 4.0 A 8.0 A 8.0 A 4.0 A 60 V DC 7.0 A 4.0 A 4.0 A 4.0 A 4.0 A 4.0 A 0 V DC 7.0 A 6.0 A 4.0 A.6 A 6.5 A 6.0 A 0 V DC 0.9 A 4.5 A 3.0 A 0. A.0 A 4.0 A ESB40 4 V DC 40.0 A 40.0 A 40.0 A 9.0 A 40.0 A 40.0 A 48 V DC 3.0 A 40.0 A 40.0 A 0.0 A 0.0 A 40.0 A 60 V DC 8.0 A 3.0 A 40.0 A 5.0 A 6.0 A 34.0 A 0 V DC 8.0 A 7.0 A 30.0 A.8 A 7.0 A 8.0 A 0 V DC.0 A 5.0 A 5.0 A 0.3 A. A 4.5 A ESB63 4 V DC 50.0 A 63.0 A 63.0 A.0 A 44.0 A 63.0 A 48 V DC 5.0 A 43.0 A 63.0 A.0 A.0 A 47.0 A 60 V DC 0.0 A 35.0 A 60.0 A 5.5 A 8.0 A 38.0 A 0 V DC 9.0 A 9.0 A 33.0 A.0 A 8.0 A.0 A 0 V DC. A 5.5 A 7.0 A 0.3 A. A 5.0 A 3 current paths in series DC-/DC-3 switching DC with N.C. contacts (N.C.) Type DC- (L/R ms) Rated operating current path current paths voltage U e in series 3 current paths in series DC-3 (L/R ms) current path current paths in series ESB0-0 4 V DC 4 A 0 A - 6 A 0 A - 48 V DC 7 A 4 A - 3 A 6 A - 60 V DC 4.5 A 0 A - A 4 A - 0 V DC.5 A 4.4 A A.8 A - 0 V DC 0. A.5 A - 0. A 0.6 A - ESB4 4 V DC 4.5 A 4.0 A 4.0 A 6.3 A.0 A 9.0 A 48 V DC 7.5 A.5 A.0 A 3. A 5.4 A 9.4 A 60 V DC 4.5 A 0.0 A 7.5 A.0 A 4.3 A 7.5 A 0 V DC.6 A 4.4 A 9.5 A 0.7 A.9 A 4. A 0 V DC 0. A.4 A 3.8 A 0. A 0.6 A.6 A 3 current paths in series SBC03005S00 ABB
15 ESB Installation Contactors - Lighting Application Technical Data Switching of lamp load The following table shows the number of lamps which can be connected per phase at 30 V, 50 Hz. Air temperature, near the contactor, must be limited to 55 C. Please, note that the given capacitor load must not be exceeded, otherwise inadmissible high inrush current peaks could occur. These are influenced by the length and cross section of the wire used, the type of power supply unit and specifications of the lamp brand. For these reasons, values in the table are for information only. Numbers are given for a 30 V voltage distributed between phase and neutral: single phase (phase + neutral) or three-phases (3 phases + neutral), lamps are wired in star connection. In the case of three-phase supply without neutral, 30 V phase-to-phase, the permissible number of lamps per phase will be that given in the table multiplied by Lamp type Lamp data Permissible number of lamps per phase (30 V, 50 Hz ) Incandescent lamps Fluorescent lamps Uncompensated and series compensation Watt I n A ESB0 ESB4 ESB40 ESB63 μf Two-lamp circuit x 0 x 0.3 x x 6 x 85 x 40 x 40 x 0. x 7 x 0 x 65 x 05 x 4 x 0.4 x 3 x 6 x 5 x 65 x 58 x 0.34 x 0 x x 40 x 65 x 65 x 0.34 x 0 x x 40 x 65 x 5 x 0.65 x 4 x 5 x 8 x 8 x 40 x 0.75 x 4 x 5 x 8 x 8 Parallel compensation High pressure mercury-vapor lamps Uncompensated Parallel compensation Lamps with electronic power supply units / V / V x x x x x x Capacitor Lamp type Lamp data Permissible number of lamps per phase (30 V, 50 Hz ) Halogen metal-vapor lamps Uncompensated Parallel compensation Low pressure sodium-vapor lamps Uncompensated Parallel compensation High pressure sodium-vapor lamps Uncompensated Parallel compensation Transformers for halogen low voltage lamps ( or 4 V AC) Watt I n A ESB0 ESB4 ESB40 ESB63 μf / / V / / V Transformers Permissible number of transformers per circuit for Watt (30 V, 50 Hz) Capacitor L L L 30 V 30 V L L 30 V L3 30 V 30 V 30 V 30 V N L3 N Single-phase Three-phase Three-phase with neutral 400 V SBC03007S00 ABB 3
16 0 A AC-/AC-7a EN0 Installation Contactors - Manually / Automatic Operated AC Operated 3 0 = Off Application Certifications and Approvals The EN contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and UL CSA CCC CE can be integrated easily in dedicated panels. Description The EN0 contactors are used for the control of single phase loads up to 0 A. They operate with an AC coil. EN contactors have a built-in toggle switch to select between three function modes: Off position, automatic run (normal contactor function), manual override with a return to Auto the next time the coil is energized. This offers many advantages as: You can make functional test before installation start-up. It can be used for maintenance operation, to change lamps and test it. It provides higher safety and drop out as you can switch the application manually. The toggle switch is also used for household application like water heating where double tariff of kwh is used. Ordering Details Main poles Nb of Control coil voltage Type Order code Pack (ing) Weight modules 50 Hz 60 Hz pieces kg ( pce) 3 4 V 8 V EN0-0 GHE30R V 64 V GHE30R A U T O S T 0 P M A N Automatic run A N.O. 4 I = ON 4 Mounting positions Pos Main Technical Data For complete technical data see SBC03005S00.pdf Main poles Rated operational voltage U e 50 V acc to. IEC I e AC- / AC-7a Rated operational current (for air temperature close to contactor θ 55 C) 0 A and IEC 6095 P e AC- Rated operational power 30 V 4 kw Magnet system Coil operating limits (acc. to IEC ) U c (at θ 55 C) Average pull-in coil consumption value 8 VA / 5 W Average holding coil consumption value 3. VA /. W Connecting capacity Main pole terminals Rigid x.5 0 mm x.5 4 mm Coil terminals Rigid x mm x mm 58.8" " Pos. 4 Pos. 3 Pos. Pos., 3, 4, ± mm EN/IEC " ". 0.43" " " Dimensions: mm, inches SBC03008S00 4 ABB
17 4 A AC-/AC-7a EN4 Installation Contactors - Manually / Automatic Operated AC / DC Operated 3 0 = Off Application Certifications and Approvals The EN contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and UL CSA CCC CE can be integrated easily in dedicated panels. Description The EN4 contactors are used for the control of single and three-phase loads up to 4 A. They operate with a DC coil. EN contactors have a built-in toggle switch to select between three function modes: Off position, automatic run (normal contactor function), manual Override with a return to Auto the next time the coil is energized. This offers many advantages as: You can make functional test before installation start-up, it can be used for maintenance operation, to change lamps and test it, it provide higher safety and drop out as you can switch the application manually. The toggle switch is also used for household application like water heating where double tariff of kwh is used. Ordering Details Main poles Nb of Control coil voltage Type Order code Pack (ing) Weight modules Hz DC pieces kg ( pce) V 4 V EN4-40 GHE360R /40 V 30/40 V GHE360R A U T O S T 0 P M A N Automatic run A 4 N.O. A 3 N.O. N.C. 4 R3 R V 4 V EN4-3 GHE3660R /40 V 30/40 V GHE3660R /40 V 30/40 V EN4-30 GHE3650R I = ON A 4 3 N.O. 6 Mounting positions Pos Main Technical Data For complete technical data see SBC03005S00.pdf Main poles Rated operational voltage U e 400 V acc to. IEC I e AC- / AC-7a Rated operational current (for air temperature close to contactor θ 55 C) 4 A and IEC 6095 P e AC- Rated operational power 30 V 5.3 kw 400 V 6 kw Magnet system Coil operating limits (acc. to IEC ) U c (at θ 55 C) Average pull-in coil consumption value 4 VA / 4 W Average holding coil consumption value 4 VA / 4 W Connecting capacity Main pole terminals Rigid x.5 0 mm x.5 4 mm Coil terminals Rigid x 4 mm x mm 58.8" 36.4" Pos. 4 Pos. Pos. 3 Pos., 3, 4, ± mm EN/IEC " " Pos " " " Dimensions: mm, inches SBC03009S00 ABB 5
18 40 A AC-/AC-7a EN40 Installation Contactors - Manually / Automatic Operated AC / DC Operated 3 0 S T 0 A P U T O M A N 0 = Off Automatic run Application Certifications and Approvals The EN contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products UL CSA CCC CE and can be integrated easily in dedicated panels. Description The EN40 contactors are used for the control of single and three-phase loads up to 40 A. They operate with a DC coil. EN contactors have a built-in toggle switch to select between three function modes: Off position, automatic run (normal contactor function), manual Override with a return to Auto the next time the coil is energized. This offers many advantages as: You can make functional test before installation start-up, it can be used for maintenance operation, to change lamps and test it, it provide higher safety and drop out as you can switch the application manually. The toggle switch is also used for household application like water heating where double tariff of kwh is used. Ordering Details Main poles Nb of Control coil voltage Type Order code Pack (ing) Weight modules Hz DC pieces kg ( pce) A 4 N.O. A 3 N.O. N.C. 3 4 R3 R V 4 V EN40-40 GHE340R V 0 V GHE340R /40 V 30/40 V GHE340R V 4 V EN40-3 GHE3460R /40 V 30/40 V GHE3460R /40 V 30/40 V EN40-30 GHE3450R I = ON A 4 3 N.O /40 V 30/40 V EN40-0 GHE3440R A N.O. 4 Mounting positions Pos Main Technical Data For complete technical data see SBC03005S00.pdf Main poles Rated operational voltage U e 400 V acc to. IEC I e AC- / AC-7a Rated operational current (for air temperature close to contactor θ 55 C) 40 A and IEC 6095 P e AC- Rated operational power 30 V 8.8 kw 400 V 6 kw Magnet system Coil operating limits (acc. to IEC ) U c (at θ 55 C) Average pull-in coil consumption value 5 VA / 5 W Average holding coil consumption value 5 VA / 5 W Connecting capacity Main pole terminals Rigid x.5 5 mm x.5 0 mm Coil terminals Rigid x 4 mm x mm 58.8" 54.3" Pos. 4 Pos. 3 Pos. Pos., 3, 4, ± mm EN/IEC " " Pos " " " Dimensions: mm, inches SBC030S00 6 ABB
19 EN Installation Contactors - Manually / Automatic Operated Technical Data Main Pole - Utilization Characteristics according to IEC Contactor types: AC operated EN0 AC / DC operated EN4 EN40 Rated operational voltage Ue max. V Rated frequency limits Hz 50/60 Utilization category AC- / AC-7a for air temperature close to contactor < 55 C Max. rated operational current Ie AC- / AC-7a N.O. A N.C. A Short-circuit protection for contactors gg type fuse A Rated short-time withstand current Icw at 40 C ambient temp., in free air, from a cold state 0 s A 7 76 Heat dissipation per pole Ie / AC- / AC-7a W 4 Max. electrical switching frequency for AC- / AC-7a cycles/h 300 Electrical Durability for AC- / AC-7a cycles Mechanical durability millions of operating cycles General Technical Data Contactor types: AC operated EN0 AC / DC operated EN4 EN40 Rated insulation voltage U i according to IEC V Rated impulse withstand voltage U imp. kv 6 Standards IEC / EN and IEC 6095 / EN 6095 Air temperature close to contactor for operation at U c C (Type EN4...40: for ambient temperature > 40 C, add ESB-DIS (/ module) at every second contactor) for storage C Climatic withstand IEC , UTE execution * Operating altitude m 000 Shock withstand 0 g / 4 ms / axes X Y Z Mounting positions Pos, 3, 4, ±30 Pos 5 : not allowed for EN0 Pos Pos. 4 Pos. 3 Pos. Fixing on rail acc. to IEC 6075 and EN mm * EN0 only Pos. /3/4/± 30 Pos. 5 SBC0304S00 ABB 7
20 EN Installation Contactors - Manually / Automatic Operated Technical Data Magnet System Characteristics Contactor types: AC operated EN0 AC / DC operated EN4 EN40 Rated operational voltage U e max. - at 50 Hz V at 60 Hz V V DC Coil operating limits acc. to IEC x U c (at θ 55 C) Drop-out voltage in % of U c approx % approx % Frequency range Hz 50/ Coil consumption Average pull-in value VA / W 8 / 5 4 / 4 5 / 5 Average holding value VA / W 3. /. 4 / 4 5 / 5 Operating time between coil energization and: N.O. contact closing ms 40 between coil de-energization and: N.O. contact opening ms 40 Connecting Characteristics Contactor types: EN0 EN4 EN40 Connecting capacity (min.... max.) Main pole terminals Rigid x mm² x mm² Capacity acc. to UL/CSA AWG Coil terminals Rigid x mm² x mm² Capacity acc. to UL/CSA AWG Degree of protection acc. to IEC / EN and IEC 6059 / EN 6059 Protection against direct contact in acc. with EN 5074 All terminals IP0 Screwdriver type Main poles Flat Ø 5 / Pozidriv Flat Ø 7.5 / Pozidriv Coil terminals Flat Ø 5 / Pozidriv Flat Ø 5 / Pozidriv Stripping length Main poles mm 0 3 Coil terminals mm 7 Tightening torque Main poles Nm..5 Coil terminals Nm 0.9 SBC0304S00 8 ABB
21 ESB, EN Installation Contactors Main Accessories Sealing cover ESB-PLK40/63 Ordering Details Auxiliary Contact Blocks Contactor Contact blocks Type Order code Pack (ing) Weight type pieces kg ( pce) ESB EH04-0 GHE3403R EN EH04- GHE3403R Auxiliary Contact Blocks ESB-PLK4 Sealing cover Contactor type Type Order code Pack (ing) pieces Weight kg ( pce) ESB4, EN4 ESB-PLK4 GHE30903R ESB , EN40 ESB-PLK40/63 GHE340903R Distance piece Contactor type Type Order code Pack (ing) pieces Weight kg ( pce) ESB4...63, EN ESB-DIS GHE3090R EH04-0 Contact Blocks EH04-0 EH04- Labelling material ESB4-40 Distance piece Labelling material Contactor type ESB0...63, EN Type Order code Pack (ing) pieces Weight kg ( pce) Label - unlabelled* SZ-KZS GHS0946R Label - numbering -40 SZ-KZS/ GHS0946R Label - numbering * -0 SZ-KZS/6 GHS0946R Label - numbering 4 * -0 SZ-KZS/9 GHS0946R Label - numbering 4 * -0 SZ-KZS/0 GHS0946R Label - labelled L SZ-KZS/ GHS0946R Label - labelled L SZ-KZS/ GHS0946R Label - labelled L3 SZ-KZS/3 GHS0946R Note: * The unlabelled can be labelled by water-resistant and permanent marker or by means of computer-controlled labelling system (plotter). Special labels on request: minimum quantities 50 ESB-DIS SZ-KZS... SBC03006S00 ABB 9
22 Index Order codes Order code Type Page Order code Type Page Order code Type Page GHE3090R000 ESB-DIS 9 GHE3930R0004 ESB4-5 GHE36930R0007 ESB63-7 GHE30903R000 ESB-PLK4 9 GHE3930R0006 ESB4-5 GHE36940R000 ESB GHE30R000 ESB0-0 4 GHE3930R0007 ESB4-5 GHE36940R0006 ESB GHE30R000 ESB0-0 4 GHE3930R004 ESB4-5 GHE36950R0006 ESB GHE30R0003 ESB0-0 4 GHE3960R000 ESB4-3 5 GHE36950R0007 ESB GHE30R0004 ESB0-0 4 GHE3960R000 ESB4-3 5 GHE36960R0004 ESB GHE30R0005 ESB0-0 4 GHE3960R0003 ESB4-3 5 GHE36960R0006 ESB GHE30R0006 ESB0-0 4 GHE3960R0004 ESB4-3 5 GHE36980R0006 ESB63-7 GHE30R0007 ESB0-0 4 GHE3960R0006 ESB4-3 5 GHS0946R0004 SZ-KZS 9 GHE30R004 ESB0-0 4 GHE3960R0007 ESB4-3 5 GHS0946R0005 SZ-KZS/ 9 GHE30R005 ESB0-0 4 GHE3960R004 ESB4-3 5 GHS0946R000 SZ-KZS/6 9 GHE30R000 ESB0-0 4 GHE3970R000 ESB4-3 5 GHS0946R003 SZ-KZS/9 9 GHE30R000 ESB0-0 4 GHE3970R000 ESB4-3 5 GHS0946R004 SZ-KZS/0 9 GHE30R0003 ESB0-0 4 GHE3970R0003 ESB4-3 5 GHS0946R005 SZ-KZS/ 9 GHE30R0004 ESB0-0 4 GHE3970R0004 ESB4-3 5 GHS0946R006 SZ-KZS/ 9 GHE30R0005 ESB0-0 4 GHE3970R0006 ESB4-3 5 GHS0946R007 SZ-KZS/3 9 GHE30R0006 ESB0-0 4 GHE3970R0007 ESB4-3 5 GHE30R0007 ESB0-0 4 GHE3970R004 ESB4-3 5 GHE30R004 ESB0-0 4 GHE3403R000 EH GHE30R005 ESB0-0 4 GHE3403R000 EH04-9 GHE330R000 ESB0-4 GHE340903R000 ESB-PLK40/63 9 GHE330R000 ESB0-4 GHE340R000 EN GHE330R0003 ESB0-4 GHE340R0004 EN GHE330R0004 ESB0-4 GHE340R0006 EN GHE330R0005 ESB0-4 GHE3440R0006 EN GHE330R0006 ESB0-4 GHE3450R0006 EN GHE330R0007 ESB0-4 GHE3460R000 EN GHE330R004 ESB0-4 GHE3460R0006 EN GHE330R005 ESB0-4 GHE3490R000 ESB GHE30R000 EN0-0 4 GHE3490R000 ESB GHE30R0006 EN0-0 4 GHE3490R0003 ESB GHE360R000 EN GHE3490R0004 ESB GHE360R0006 EN GHE3490R0006 ESB GHE3650R0006 EN GHE3490R0007 ESB GHE3660R000 EN4-3 5 GHE3490R0008 ESB GHE3660R0006 EN4-3 5 GHE3490R004 ESB GHE390R000 ESB GHE34930R000 ESB40-6 GHE390R000 ESB GHE34930R0006 ESB40-6 GHE390R0003 ESB GHE34940R000 ESB GHE390R0004 ESB GHE34940R0006 ESB GHE390R0006 ESB GHE34950R000 ESB GHE390R0007 ESB GHE34950R0006 ESB GHE390R004 ESB GHE34950R0007 ESB GHE390R000 ESB GHE34960R000 ESB GHE390R000 ESB GHE34960R0006 ESB GHE390R0003 ESB GHE3690R000 ESB GHE390R0004 ESB GHE3690R000 ESB GHE390R0006 ESB GHE3690R0003 ESB GHE390R0007 ESB GHE3690R0004 ESB GHE390R004 ESB GHE3690R0006 ESB GHE3930R000 ESB4-5 GHE3690R0007 ESB GHE3930R000 ESB4-5 GHE3690R0008 ESB GHE3930R0003 ESB4-5 GHE3690R004 ESB ABB
23 Index Types Type Order code Page Type Order code Page Type Order code Page EH04- GHE3403R000 9 GHE3970R GHE3690R EH04-0 GHE3403R000 9 GHE3970R GHE3690R EN0-0 GHE30R000 4 GHE3970R GHE3690R GHE30R GHE3970R004 5 GHE3690R EN4-30 GHE3650R ESB4- GHE3930R000 5 GHE3690R004 7 EN4-3 GHE3660R000 5 GHE3930R000 5 ESB-DIS GHE3090R000 9 GHE3660R GHE3930R ESB-PLK4 GHE30903R000 9 EN4-40 GHE360R000 5 GHE3930R ESB-PLK40/63 GHE340903R000 9 GHE360R GHE3930R SZ-KZS GHS0946R EN40-0 GHE3440R GHE3930R SZ-KZS/ GHS0946R EN40-30 GHE3450R GHE3930R004 5 SZ-KZS/6 GHS0946R000 9 EN40-3 GHE3460R000 6 ESB4-3 GHE3960R000 5 SZ-KZS/9 GHS0946R003 9 GHE3460R GHE3960R000 5 SZ-KZS/0 GHS0946R004 9 EN40-40 GHE340R000 6 GHE3960R SZ-KZS/ GHS0946R005 9 GHE340R GHE3960R SZ-KZS/ GHS0946R006 9 GHE340R GHE3960R SZ-KZS/3 GHS0946R007 9 ESB0-0 GHE30R000 4 GHE3960R GHE30R000 4 GHE3960R004 5 GHE30R ESB4-40 GHE390R000 5 GHE30R GHE390R000 5 GHE30R GHE390R GHE30R GHE390R GHE30R GHE390R GHE30R004 4 GHE390R GHE30R005 4 GHE390R004 5 ESB0- GHE330R000 4 ESB40-0 GHE34940R000 6 GHE330R000 4 GHE34940R GHE330R ESB40- GHE34930R000 6 GHE330R GHE34930R GHE330R ESB40-30 GHE34950R000 6 GHE330R GHE34950R GHE330R GHE34950R GHE330R004 4 ESB40-3 GHE34960R000 6 GHE330R005 4 GHE34960R ESB0-0 GHE30R000 4 ESB40-40 GHE3490R000 6 GHE30R000 4 GHE3490R000 6 GHE30R GHE3490R GHE30R GHE3490R GHE30R GHE3490R GHE30R GHE3490R GHE30R GHE3490R GHE30R004 4 GHE3490R004 6 GHE30R005 4 ESB63- GHE36980R ESB4-04 GHE390R000 5 ESB63-0 GHE36940R000 7 GHE390R000 5 GHE36940R GHE390R ESB63- GHE36930R GHE390R ESB63-30 GHE36950R GHE390R GHE36950R GHE390R ESB63-3 GHE36960R GHE390R004 5 GHE36960R ESB4-3 GHE3970R000 5 ESB63-40 GHE3690R000 7 GHE3970R000 5 GHE3690R000 7 GHE3970R GHE3690R ABB
24 Contact us ABB France Low Voltage Products Division 0, rue Ampère Z.I. - B.P. 4 F Chassieu cedex / France ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 8 D-693 Heidelberg / Germany Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 0 ABB All rights reserved SBC C00 - Printed in France (W 0.0 Ferréol) You can find the address of your local sales organisation on the ABB home page -> Low Voltage products
Catalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationInstallation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201
Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationESB and EN installation contactors Application handbook
ESB and EN installation contactors Application handbook 2 2CDC103022M0201 Content 1 Basic function of installation contactors 4 2 Modular DIN rail components 5 3 ESB/EN Installation contactors 6 4 Technical
More informationThree-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationZS6-S Screw Clamp Terminal Blocks Disconnect with blade
Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More informationZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket
Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied
More informationZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket
Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver
More informationUncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationZS25 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationSystem pro M compact Miniature Circuit Breaker S 200/S 200 M
Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M 2CDC021023S0012 2CDC021038S0012 The miniature circuit breakers of the System pro M compact series S 200 and S 200 M provide state-of-the-art
More informationThermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationThermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationMultifunctional three-phase monitoring relays CM-MPS CM-MPS.43
Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43 The three-phase monitoring relay CM-MPS.43 monitors the phase parameters phase sequence, phase failure, over- and undervoltage
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More informationMolded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
More informationPanorama. Motor protection and control Manual motor starters, contactors and overload relays
Panorama Motor protection and control Manual motor starters, contactors and overload relays ABB sets a new standard in motor control and power switching Featuring AF technology as standard, the latest
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More informationVEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationSwitching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches
Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationABB i-bus KNX Switch Actuators SA/S Product Information
ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationZS10 Screw Clamp Terminal Block
Technical Datasheet 1SNK 161 004 D0201 ZS10 Screw Clamp Terminal Block Feed-through Catalogue Page 1SNK 161 004 S0201 10 mm² 6 AWG 8 mm 0.315 in Spacing Features and Benefits 53 2.09" Save space by connecting
More informationABB i-bus KNX SA/S Switch Actuators Product Manual
ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional
More informationABB i-bus KNX Switch Actuators SA/S Product Information
ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,
More informationSiemens AG 2011. Switching Devices. Configuration Manual 10/2010 SENTRON. Answers for infrastructure.
Siemens AG 20 Switching Devices Configuration Manual 0/200 SETRO Answers for infrastructure. Siemens AG 20 Siemens AG 20 Switching Devices 4 Introduction 7 Control switches, 5TE8 9 Pushbuttons, 5TE4 Light
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More information1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting
Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8
More informationUncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA
Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA Miniature Circuit Breaker SU 200 M The next generation MCB for UL/CSA applications within
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationMicro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationMONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA
w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions
More informationActuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
More informationLow Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More informationPHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More information60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More information34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
More information