1 BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary switches can be mounted without tools. When used with terminal covers, the devices are also sealable. Insta contactors without manual switch They are playing an increasingly significant role in lighting circuits in buildings. Insta contactors are increasingly used in industry for motors where distribution technology plays a major role, e.g. in installations for heat pumps and air conditioning technology. In addition to their basic function, they can also be used to switch single-phase and three-phase electrical motors on and off. Insta contactors with manual switch A key feature of Insta contactors with manual operation is the fact that users can switch consumers/loads on and off by hand. Benefits Extremely long service life of 3 million switching cycles is a testimony to their reliability Switching position indicator for fast recognition of operating state offers greater safety when checking the plant. Safe insertion of conductor through cable entry funnel saves time during installation Insulated right through to the cable entry funnel. This provides enhanced touch protection Auxiliary switches can be retrofitted on all versions even on the type 20 A. More functionality when using the devices. Insta contactors with O/I/Automatic function enable the testing of a plant by manual switch without the need to apply a control voltage. /20 Siemens ET B1 10/200

2 Siemens AG 200 BETA Switching 5TT5 Insta contactors, AC technology Technical specifications 1) For NO contacts only. Insta contactors 5TT5 0. 5TT5 2., 5TT5 3. Auxiliary switches 5TT5 4. 5TT5 5. 5TT5 910 Standards IEC , IEC , IEC 61095; EN , EN , EN 61095, VDE 0660 Approved acc. to VDE 0637 Number of poles Rated frequency at AC Hz 50/60 Rated control voltage U c VAC 24, , 115, , , Operating range U c Rated operational voltage U e VAC /400 Rated operational current I e A /4 (230/400 V) Rated power dissipation P v Pick-up power (without manual switch VA/W 6/3. 10/5 15.4/6 -- or manual switch in "I" position) Pick-up power (with manual switch in "AUTO" position) VA/W 12/10 33/25 62/50 -- Holding power VA/W 2./ / /3 -- Per contact VA Switching times Closing (NO contacts) ms Opening (NO contacts) ms Closing (NC contacts) ms Opening (NC contacts) ms Rated impulse withstand voltage U imp kv 4 Rated insulation voltage U i V Contact gap, minimum mm Electrical service life At I e and load AC-1/AC-7a For switching cycles AC-3/AC-7b Mechanical service life For switching cycles 3 million Maximum switching frequency At load In switching cycles/h Switching of resistive loads AC-1/AC-7a For rated operational power P s Single-phase 230 V kw Three-phase 400 V kw Switching of three-phase asynchronous motors AC-3/AC-7b For rated operational power P s Single-phase 230 V kw 1.3 1) Three-phase 400 V kw Minimum switching capacity V; ma 17; 50 12; 5 Overload withstand capability Per conducting path (NO contacts only) At 10 s A Short-circuit protection, acc. to coordination type 1 Back-up fuse characteristic gl/gg A Terminals ± screw (Pozidriv) Coil connection Main connection Tightening torques Coil connection Nm Main connection Nm Conductor cross-sections Coil connection Rigid mm Flexible, mm with end sleeve Main connection Rigid mm Flexible, with end sleeve mm Permissible ambient temperature For operation C For storage C Degree of protection Acc. to EN IP20, with connected conductors 600 Siemens ET B1 10/200 /21

3 BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Selection and ordering data 5TT TT TT Version U e I e U c MW DT Order No. Price per PU Insta contactors without manual switch PG PU PS*/ P. unit VAC AAC VAC 1 unit Unit(s) Unit(s) kg Weight per PU approx. For alternating current continuous operation, with switching position indication, with AC magnetic system 2NO } 5TT } 5TT NO, 1NC } 5TT } 5TT NC } 5TT } 5TT NO } 5TT B 5TT } 5TT NO, 1NC } 5TT B 5TT B 5TT NO For high capacitive loads up to 150 μf B 5TT NO, 2NC } 5TT } 5TT NC } 5TT B 5TT NO } 5TT } 5TT NO, 1NC B 5TT B 5TT NO, 2NC B 5TT B 5TT NC } 5TT B 5TT NO } 5TT } 5TT NO, 1NC } 5TT B 5TT NO, 2NC B 5TT B 5TT NC } 5TT B 5TT Auxiliary switches For mounting on right-hand side Max. one auxiliary switch per Insta contactor. 2 NO 230, AC } 5TT NO, 1NC 230, AC } 5TT TT Sealable terminal covers For Insta contactor 20 A 1 B 5TT For Insta contactor 25 A 2 B 5TT For Insta contactor 40 A and 63 A 3 B 5TT /22 Siemens ET B1 10/200

4 Siemens AG 200 BETA Switching 5TT5 Insta contactors, AC technology Version U e I e U c MW DT Order No. Price per PU PG PU PS*/ P. unit VAC AAC VAC 1 unit Unit(s) Unit(s) kg Insta contactors with manual switch 0/I/Automatic Weight per PU approx. For alternating current continuous operation, with switching position indication, with AC magnetic system 2 NO } 5TT } 5TT NO, 1 NC B 5TT B 5TT TT NO } 5TT } 5TT NO, 1 NC } 5TT B 5TT TT NO } 5TT B 5TT NO, 1 NC B 5TT B 5TT NO } 5TT TT Auxiliary switches For mounting on right-hand side Max. one auxiliary switch per Insta contactor. 2 NO 230, AC } 5TT NO, 1 NC 230, AC } 5TT Sealable terminal covers For Insta contactor 20 A 1 B 5TT For Insta contactor 25 A 2 B 5TT For Insta contactor 40 A and 63 A 3 B 5TT Siemens ET B1 10/200 /23

5 BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Dimensional drawings Insta contactors, AC technology Without manual switch I2_1237 I2_123 I2_ TT TT TT TT TT TT TT TT TT With manual switch I2_1241 I2_1242 I2_ TT TT TT TT TT TT TT Auxiliary switches I2_ TT TT Schematics A11 3 A11 21 A A (13) A A2 2 4 A A TT5 00 5TT5 01 5TT5 02 5TT5 20 5TT5 30 5TT5 40 5TT5 50 A (14) A TT5 31 5TT5 41 5TT5 51 A A TT5 32 5TT5 42 5TT5 52 A A TT5 33 5TT5 43 5TT TT TT /24 Siemens ET B1 10/200

6 Siemens AG 200 BETA Switching 5TT5 Insta contactors, AC technology More information Mounting position, Insta contactors, AC technology The installation of the devices is permissible in the positions shown in the following diagram (0 to, 270 to 0 ). There are no restrictions when the devices are installed in these normal mounting positions. 10 Manual switching with O/I/Automatic function The versions 5TT and 5TT5...- are also fitted with a manual switch. The knob allows preselection of 3 positions: Knob in the "AUTO" position Automatic mode normal protective function Knob in the "I" position Continuous operation switched on manually (without control signal, when a control signal is applied, the manual switch on reset, i.e. the knob is automatically reset to the "AUTO" position). Knob in the "O" position Off switched off (coil circuit interrupted) I2_1236b Heat dissipation If several Insta contactors with AC magnetic system are mounted in series in a distribution board, there are no restrictions for the types 25 A, 40 A and 63 A within the permissible ambient temperature range up to 55 C. For 20 A types within the temperature range up to 40 C, a 5TG 240 spacer must be installed after every third Insta contactor, and in the temperature range over 40 C to 55 C, after every second contactor. Plant test without applying a control voltage Insta contactors with O/I/Automatic function enable the testing of a plant by manual switch without the need to apply a control voltage. Automatic by control signal When applying a control signal to the terminals A1 and A2, the Insta contactors can be reset from continuous operation mode ("I" position) to automatic mode ("AUTO" position). Siemens ET B1 10/200 /25

7 BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Switching of AC voltages DC-1 Permissible DC switching currents for NO contacts with resistive load 1 contact 2 contacts in series 3contacts in series 5TT5 0 2-pole, 20 A I e for U e =24V DC A U e =110V DC A U e =220V DC A TT5 2, 5TT5 3 4-pole, 25 A I e for U e =24V DC A U e =110V DC A U e =220V DC A TT5 4 4-pole, 40 A I e for U e =24V DC A U e =110V DC A U e =220V DC A TT5 5 4-pole, 63 A I e for U e =24V DC A U e =110V DC A U e =220V DC A contacts in series Switching of lamps Incandescent lamp loads, lamp type 1000 W 500 W 200 W 100 W 60 W 5TT5 0, 2-pole 20 A Per NO/NC contact TT5 2, 4-pole 25 A Per NO/NC contact TT5 3, 4-pole 25 A Per NO/NC contact TT5 4, 4-pole 40 A Per NO/NC contact TT5 5, 4-pole 63 A Per NO/NC contact Maximum number of lamps in units, per NO/NC contact at 230 V AC, 50 Hz. Fluorescent and compact lamps in ballast operation (KVG) Uncorrected Parallel-corrected DUO switching, 2-lamp Lamp type W L1 L36 L5 L1 L36 L5 2 L1 2 L36 2 L5 Capacitor capacitance μf TT5 0, 2-pole 20 A Per NO/NC contact TT5 2, 4-pole 25 A Per NO/NC contact TT5 3, 4-pole 25 A Per NO/NC contact TT5 4, 4-pole 40 A Per NO/NC contact TT5 5, 4-pole 63 A Per NO/NC contact Fluorescent and compact lamps with electronic primary switching device (ECG) 1 lamp 2 lamps Lamp type W 1 L1 1 L36 1 L5 2 L1 2 L36 2 L5 5TT5 0, 2-pole 20 A Per NO/NC contact TT5 2, 4-pole 25 A Per NO/NC contact TT5 3, 4-pole 25 A Per NO/NC contact TT5 4, 4-pole 40 A Per NO/NC contact TT5 5, 4-pole 63 A Per NO/NC contact High-pressure mercury-vapor lamps (HQL) (permissible number of lamps in units per NO contact/nc contact at 230 V AC, 50 Hz) Uncorrected Parallel-corrected Lamp type W Capacitor capacitance μf TT5 0, 2-pole 20 A Per NO/NC contact TT5 2, 4-pole 25 A Per NO/NC contact TT5 3, 4-pole 25 A Per NO/NC contact TT5 4, 4-pole 40 A Per NO/NC contact TT5 5, 4-pole 63 A Per NO/NC contact Halogen metal-vapor lamps (HQI) Uncorrected Parallel-corrected With electronic ballast PCI Lamp type W Capacitor capacitance μf TT5 0, 2-pole 20 A Per NO/NC contact TT5 2, 4-pole 25 A Per NO/NC contact TT5 3, 4-pole 25 A Per NO/NC contact TT5 4, 4-pole 40 A Per NO/NC contact TT5 5, 4-pole 63 A Per NO/NC contact /26 Siemens ET B1 10/200

8 Siemens AG 200 BETA Switching 5TT5 Insta contactors, AC technology High-pressure sodium-vapor lamps (NAV) Uncorrected Parallel-corrected With electronic ballast PCI Lamp type W Capacitor capacitance μf TT5 0, 2-pole 20 A Per NO/NC contact TT5 2, 4-pole 25 A Per NO/NC contact TT5 3, 4-pole 25 A Per NO/NC contact TT5 4, 4-pole 40 A Per NO/NC contact TT5 5, 4-pole 63 A Per NO/NC contact High-pressure sodium-vapor lamps Uncorrected Parallel-corrected Lamp type W Capacitor capacitance μf TT5 0, 2-pole 20 A Per NO/NC contact TT5 2, 4-pole 25 A Per NO/NC contact TT5 3, 4-pole 25 A Per NO/NC contact TT5 4, 4-pole 40 A Per NO/NC contact TT5 5, 4-pole 63 A Per NO/NC contact Fluorescent Lumilux lamps T5 type FC, with electronic ballast (ECG) 1 lamp 2 lamps Lamp type W TT5 0, 2-pole 20 A Per NO/NC contact TT5 2, 4-pole 25 A Per NO/NC contact TT5 3, 4-pole 25 A Per NO/NC contact TT5 4, 4-pole 40 A Per NO/NC contact TT5 5, 4-pole 63 A Per NO/NC contact Fluorescent Lumilux lamps T5 type HE, with electronic ballast (ECG) 1 lamp 2 lamps Lamp type W TT5 0, 2-pole 20 A Per NO/NC contact TT5 2, 4-pole 25 A Per NO/NC contact TT5 3, 4-pole 25 A Per NO/NC contact TT5 4, 4-pole 40 A Per NO/NC contact TT5 5, 4-pole 63 A Per NO/NC contact Fluorescent Lumilux lamps T5 type HO, with electronic ballast (ECG) 1 lamp 2 lamps Lamp type W TT5 0, 2-pole 20 A Per NO/NC contact TT5 2, 4-pole 25 A Per NO/NC contact TT5 3, 4-pole 25 A Per NO/NC contact TT5 4, 4-pole 40 A Per NO/NC contact TT5 5, 4-pole 63 A Per NO/NC contact Siemens ET B1 10/200 /27

Siemens AG 2011. Switching Devices. Configuration Manual 10/2010 SENTRON. Answers for infrastructure.

Siemens AG 2011. Switching Devices. Configuration Manual 10/2010 SENTRON. Answers for infrastructure. Siemens AG 20 Switching Devices Configuration Manual 0/200 SETRO Answers for infrastructure. Siemens AG 20 Siemens AG 20 Switching Devices 4 Introduction 7 Control switches, 5TE8 9 Pushbuttons, 5TE4 Light

More information

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

Catalog. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation

More information

Low Voltage Switchgear

Low Voltage Switchgear Low Voltage Switchgear Index Contents: Contactors K03, K07 Mini Contactors 2 BR6 Thermal overload relay 8 KNL6 - KNL30 Contactors 10 BR16, BR30 Thermal overload relay 17 KNL6G - KNL30G Contactors 19 KNL43,

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

5,5 5,5 20-1 HKM11V HKM11X K1W12D01MC... LA1W12W. 01 1 0,32 5,5 5,5 20 1 - - HKM.. K1W12D10MC... LA1W12W. 10 1 0,32

5,5 5,5 20-1 HKM11V HKM11X K1W12D01MC... LA1W12W. 01 1 0,32 5,5 5,5 20 1 - - HKM.. K1W12D10MC... LA1W12W. 10 1 0,32 Mini Reversing Contactors, Mechanical Interlocked AC Operated Power Ratings Rated Aux. Contacts 2) Type Coil voltage 1) Current Built-in Additional 24 24V 50/60Hz 0 AC2, AC3 on left on right 230 220-230V

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Switching Devices Contactors and Contactor Assemblies Special Applications

Switching Devices Contactors and Contactor Assemblies Special Applications Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

BETA Protecting SITOR Semiconductor Fuses

BETA Protecting SITOR Semiconductor Fuses BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field

More information

ESB and EN installation contactors Application handbook

ESB and EN installation contactors Application handbook ESB and EN installation contactors Application handbook 2 2CDC103022M0201 Content 1 Basic function of installation contactors 4 2 Modular DIN rail components 5 3 ESB/EN Installation contactors 6 4 Technical

More information

Schneider Electric. TeSys Vacuum Contactors. June. Building a New Electric World

Schneider Electric. TeSys Vacuum Contactors. June. Building a New Electric World TeSys Vacuum Contactors June 2002 Building a New Electric World Selection guide, characteristics Contactors 5 Selection guide Contactor size LC1-V160 LC1-V320 LC1-V610 For utilisation category AC-3 Maximum

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact

Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact Data sheet Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact The CT-VWE is an electronic time relay with Impulse-ON function. It is from the CT-E range. The CT-E range is the economic range

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate

n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate SP fuse carriers with protected terminals SP fuse carriers with protected terminals www.klinkmann.com n Choice of equipment Maximum cartridge rating Type Rated current 400 V± 0 V± 690 V± gg am gg am gg

More information

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional

More information

Residual Current Protective Devices

Residual Current Protective Devices Residual Current Protective Devices /2 Introduction / 5SM3 RCCBs /9 SIQUENCE, 5SM3 and 5SU1 universal -sensitive RCCBs, type B and type B+ /12 Additional components /1 5SM2 RC units /18 5SU1 RCBOs /25

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011 Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Electronic timer CT-TGD.12

Electronic timer CT-TGD.12 2CDC 251 098 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Measuring and monitoring relays CM-MSS (4), CM-MSS (5) Thermistor motor protection relays

Measuring and monitoring relays CM-MSS (4), CM-MSS (5) Thermistor motor protection relays Data sheet Measuring and monitoring relays CM-MSS (4), Thermistor motor protection relays The devices CM-MSS (4) and (5) are used to monitor the overload of motors by the wiring temperature. The motors

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

DLA starters General information

DLA starters General information General information The construction of is based on ABB A Line contactors. The mounting plate, including a built-in A contactor, is designed to integrate an ABB manual motor starter type MS325. Starters

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 02 A2 A4 05 A5 external rubber gasket external rubber gasket external rubber gasket external rubber gasket external rubber gasket 21 25 4 69 5 stainless

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Monitoring Devices. 12/2 Introduction. Transfer switches 12/5 3KC ATC5300 transfer control devices

Monitoring Devices. 12/2 Introduction. Transfer switches 12/5 3KC ATC5300 transfer control devices Monitoring Devices /2 Introduction Transfer switches /5 3KC ATC5300 transfer control devices Monitoring devices for electrical values /9 5SV8 residual current monitors / 5TT3 voltage relays /16 5TT3 current

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuators SA/S Product Information ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

MCBs and RCDs LR TM 6000 thermal magnetic MCBs from 6 A to 63 A - B and C curves residual current devices from 25 A to 63 A - AC and A types

MCBs and RCDs LR TM 6000 thermal magnetic MCBs from 6 A to 63 A - B and C curves residual current devices from 25 A to 63 A - AC and A types MCBs and RCDs LR TM 6000 thermal magnetic MCBs from 6 A to 63 A B and C curves residual current devices from 25 A to 63 A AC and A types 6048 96 6048 50 6021 93 6021 53 MCBs: Conform to IEC 608981 Breaking

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

PHOENIX CONTACT

PHOENIX CONTACT Thermomagnetic circuit breakers CLIPLINE Data sheet 103943_en_04 PHOENIX CONTACT 2010-08-18 1 Description The UT 6-TMC M circuit breaker is a single-position overload circuit breaker with thermomagnetic

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Three-phase monitoring relay CM-PVE

Three-phase monitoring relay CM-PVE Data sheet Three-phase monitoring relay CM-PE The three-phase monitoring relay CM-PE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Safety Relays ESM/ESM-F

Safety Relays ESM/ESM-F Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information

SINGLE-POLE and MULTI-POLE

SINGLE-POLE and MULTI-POLE SINGLE-POLE and MULTI-POLE Surge Arresters Class II / (C) Connections: 1+1, 3+0, 4+0, 3+1 I max = 20 ka (8/20) MODULAR Housing 33 ISPRO C(R) 40 The ISPRO C(R) 40 series of low cost, over voltage surge

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Contactors Motor Protection Accessories

Contactors Motor Protection Accessories Main Catalogue Contactors Motor Protection Accessories Main Catalogue Contactors Motor Protection Accessories 1 2 3 4 5 6 Product Range A, AE, BC, EH, EK Contactors N and KC Contactor Relays Accessories

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

RM4TR32 three-phase network control relay RM4-T - range V

RM4TR32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 300..430 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Safety Modules Light curtains Types NLG02D, NLG13D

Safety Modules Light curtains Types NLG02D, NLG13D Safety Modules Light curtains Types NLG02D, NLG13D Screw, fixed Screw, detachable Safety Category 4, Performance Level e, according to EN 13849-1 Safety Category 4 according to EN 954-1 2 x 6 A NO safety

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies Contactors and Contactor Assemblies SIRIUS Overview The contactor assemblies can be ordered as follows: Sizes S00 to S3 Fully wired and tested, open type, with mechanical and electrical interlock. 1 )

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Reversing Contactors Open Type Version

Reversing Contactors Open Type Version BEM... A9...A40 VE5.1 BEM... A9...A40 E1112D1 VOA..-0M version >> VOA..-0M, VNA..-0M Reversing contactors... page /1 >> Reversing contactors in kit form... page /6 /0 ABB Control VOA..-0M, VNA..-0M A1

More information

13 SERIES. Electronic step relays 10-16 A 13.81 13.91

13 SERIES. Electronic step relays 10-16 A 13.81 13.91 13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Circuit diagram. Inteded use. Function

Circuit diagram. Inteded use. Function SNA 4043 K SNA 4063 K SNA 4044 K SNA 4064 K Basic unit for emergency stop and guard door applications Basic unit as per EN 62061 and EN ISO 13849-1 For safety category 4 and stop category 0 Single or twin

More information

Circuit-Breakers M4 160 for motor protection. Auxiliary contacts 161 Signalling switch Auxiliary releases

Circuit-Breakers M4 160 for motor protection. Auxiliary contacts 161 Signalling switch Auxiliary releases Circuit Breakers M4 Index Page Circuit-Breakers M4 160 for motor protection Auxiliary contacts 161 Signalling switch Auxiliary releases Insulated 3-pole busbar system 162 Terminal block DIN-rail adapters

More information

41 Series - Low profile PCB relays A. Features Plug-in / PCB Relays

41 Series - Low profile PCB relays A. Features Plug-in / PCB Relays Series - Low profile PCB relays 8-12 - 16 A 41 Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 4N1 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors/ circuit breakers up to

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

ELFA E90S MINI BREAKERS

ELFA E90S MINI BREAKERS ELFA E90S MINI BREAKERS - ELFA E90S SERIES UL Approved (UL1077) 10KA INTERUPTION CAPACITY OPTIONS FIELD KITS Auxiliary Contacts Alarm Contact Shunt Trip UV Trip Current Limiting Design (Class 3) 3 Different

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal

93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal Series - Timed socket for 34 series Features.68/.69 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt TDB106015en/05.2013 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

More information