1 Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9
2 Micro Contactor Relays 4pole C Operated RatingsTherm. Contacts 2) Coil voltage ) Distinc. dditional 50/60Hz Number Contact 2 50Hz/60Hz C5 Rated Current 400 I th acc. to Blocks Pack Weight NO NC EN500 pcs. kg/pc. 4pole, With Screw Terminals 3, E K004D , E K004D , E K004D K004D40 K004D3 K004D22 ) Other coil voltages on request. 2) Contacts suitable for electronic circuits, according to EN94754 for rated voltage DC (test ratings 7 DC, 5m). Positively guided contacts. 0
3 Micro Contactors C Operated Power Ratings C2, C3 C Rated Current ux. Contacts2) Builtin dditional 440 NO NC Coil voltage ) 50/60Hz 2 50Hz/60Hz Pack pcs. W Weight kg/pc. 3pole, With Screw Terminals K005D K005D K005D pole, With Screw Terminals K005D0 K005D0 K005D0040 ) Other coil voltages see page. 2) Contacts suitable for electronic circuits, according to EN94754 for rated voltage DC (test ratings 7 DC, 5m). Positively guided contacts.
4 Micro Contactors C Operated Power Ratings Rated Current C2, C3 C ux. Contacts2) Built dditional in NO NC Coil voltage ) 50/60Hz 2 50Hz/60Hz Pack pcs. W Weight kg/pc. 3pole, with Solder Pins Ø,5 for Printed Circuit pplications xxx3) K005L xxx3) K005L pole, with Solder Pins Ø,5 for Printed Circuit pplications xxx3) K005L0 K005L K005L0 K005L0040 Coil voltages for C operated contactors Suffix to contactor type e.g. K09D0 48 oltage Marking Rated Control oltage Us at the coil for for 50Hz 60Hz range for 50Hz min. max ,5 48 for 60Hz min. max. Suffix to contactor type e.g. K09D0 oltage Marking Rated Control oltage Us at the coil for for 50Hz 60Hz range for 50Hz min. max Standard voltages in bold type letters Operating range of magnetcoils: 0,85 x Us (min. value of rated control voltage) up to, x Us (max. value of rated control voltage) Coil not exchangeable ) Other coil voltages see page. 2) Contacts suitable for electronic circuits, according to EN94754 for rated voltage DC (test ratings 7 DC, 5m). Positively guided contacts. 3) Data on request. for 60Hz min. max.
5 Micro Reversing Contactors, Mechanical Interlocked C Operated Power Ratings Rated Current C2, C C ux. Contacts2) Builtin dditional on left on right hand side hand side Contactor Contactor 690 NO NC K K2 Coil voltage ) 50/60Hz 2 50Hz/60Hz W Pack pcs. Weight kg/pc. 3pole, with Screw Terminals K0W05D0MC... 0,4 K0W05D0MC... 0,4 K0W05D0040MC... 0,4 4pole, with Screw Terminals 3pole, with Solder Pins Ø,5 for Printed Circuit pplications xxx3) K0W05L0MC... 0,4 xxx3) K0W05L0MC... 0,4 K0W05D0MC K0W05D0MC K0W05D0040MC ) Other coil voltages see page. 2) Contacts suitable for electronic circuits, according to EN94754 for rated voltage DC (test ratings 7 DC, 5m). Positively guided contacts. 3) Data on request. 3
6 Micro Contactors Data according to IEC , DE 0660, EN Main Contacts K005D.. Rated insulation voltage U i C 480 ) Making capacity I eff at U e = 440 C 65 Breaking capacity I eff 400 C 50 cosϕ = 0,65 Utilization category C Switching of resistive load Rated operational current I e (=I th ) at 40 C, open Rated operational power of threephase resistive loads 4,7 5060Hz, cosj = 0 4, ,3 45 8, ,5 Rated operational current I e (=I th ) at 60 C, enclosed 8 Rated operational power of threephase resistive loads 3, 5060Hz, cosj = 0 3, ,5 45 5, ,5 Minimum crosssection of conductor at load with I e (=I th ) mm²,5 Utilization category C2 and C3 Switching of threephase motors Rated operational current I e 6,2 open and enclosed 6,2 0 5, Rated operational power of threephase motors 2,5 5060Hz Utilization category C4 Switching of squirrel cage motors, inching Rated operational current I e 4,9 open and enclosed 4,9 0 4, Rated operational power of threephase motors 2, 5060Hz ) Suitable at 690 for: earthedneutral systems, overvoltage category I to III, pollution degree 3 (standardindustry): Uimp = 4k. Data for other conditions on request. 4
7 Micro Contactors Data according to IEC , DE 0660, EN Main Contacts Utilization category DC Switching of resistive load Time constant L/R ms Rated operational current Ie K005D.. pole poles in series 60 0 C C C C 40 to +60 (+90) ) 40 to to to +40 C 50 to +90 Utilization category DC3 and DC5 Switching of shunt motors and series motors Time constant L/R 5ms Rated operational current Ie pole Pole in Serie 60 0 Maximum ambient temperature Operation open enclosed open enclosed with therminal overload relay Storage Short circuit protection for contactors without thermal overload relay Coordinationtype "" according to IEC 9474 Contact welding without hazard of persons max. fuse size gl (gg) 20 Coordinationtype 2 according to IEC 9474 Light contact welding accepted max. fuse size gl (gg) Contact welding not accepted max. fuse size gl (gg) For contactors with thermal overload relay the device with the smaller admissible backup fuse (contactor or thermal overload relay) determines the fuse size. Cable crosssections for contactors main connector solid or stranded flexible flexible with multicore cable end Cables per clamp mm² mm² mm² 0,5,5 0,5,5 0,5,5 2 WG 20 4 without load C3, Ie C4, Ie DC3, Ie /h /h /h /h Sx Sx xxx2) 0scurrent 50 at Ie /C3 400 W 0,2 NO NC g g 2,5 2,5 solid or stranded Frequency of operation z contactors without therminal oberload relay Mechanical life C operated DC operated Short time current Power loss per pole Resistance to shock according to IEC Shock time 20ms sinewave C operated ) With reduced control voltage range 0,9 up to,0 x Us and with reduced rated current Ie /Caccording to Ie /C3. 2) Data on request. 5
8 Micro Contactors Data according to IEC , DE 0660, EN uxiliary Contacts K004D.. K005D.. Rated insulation voltage U i C 440 ) Thermal rated current I th bis 440 mbient temperature 40 C 5 60 C 3 erlustleistung pro Pol bei I th W 0,25 Utilization category C5 Rated operational currrent I e ,5 440 Utilization category DC3 Rated operational current I e 60 0,5 Maximum ambient temperature Operation open C 40 bis +60 (+90) 2) enclosed C 40 bis +40 Storage C 40 bis +90 Short circuit protection shortcircuit current k, contact welding not accepted max. fuse size gl (gg) 0 For contactors with thermal overload relay the device with the smaller admissible control fuse (contactor or thermal overload relay) determines the fuse size. Power consumption of coils C operated inrush 9 sealed 4 W,8 Operation rage of coils in multiples of control voltage U s 0,85, Switching time at control voltage U s ±0% C operated make time ms 3 8 release time ms 5 0 arc duration ms 0 5 DC operated make time ms release time ms arc duration ms Cablecrosssection all connectors solid mm 2 0,5,5 flexible mm 2 0,5,5 flexible with multicore cable end mm 2 0,5,5 Clamps per pole 2 solid or stranded WG ) 4) ) Suitable at 690 for: earthedneutral systems, overvoltage category I to III, pollution degree 3 (standardindustry): Uimp = 4k. Data for other conditions on request. 2) With reduced control voltage range 0,9 up to,0 x U s and with reduced thermal rated current I th to I e /C5. 3) Summary switching time = release time + arc duration. 4) Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (aristor, RCunits, Diode units). 5) Data on request. 6
9 Micro Contactors for North merica Data according to UL508 Main Contacts (culus) Rated operational current "General Use" ½ ½ ½6 ½ ¾ Rated operational power of three motors at 60Hz (3ph) Rated operational power of C motors at 60Hz (ph) K005D.. K0W05D0.. K004D.. Fuse / Shortcircuit current /k 30/5 Rated voltage C C DC B300 R300 B300 R300 uxiliary Contacts (culus) Motor Rating Pn = C4 heavy pilot duty standard pilot duty Motor Rating Pn = C3 Breaking Current Ia ( = Ie = C) Millions of Operations 7
10 Micro Contactors Dimensions C operated with screw terminals K004D.. K005D.. C operated with solder connections K004L.. K005L.. Reversing Contactors with screw terminals K0W05D..MC Reversing Contactors with solder connections K0W05L..MC 8
Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationSwitching Devices Contactors and Contactor Assemblies Special Applications
Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationINDICE MINI-CONTATTORI / CONTENTS MINI-CONTACTORS. Criteri di scelta pag. 1-48 Product selection. Caratteristiche tecniche pag. 1-51 Tecnical data
Indice Contents CONTROLLO MOTORE MOTOR CONTROL INDICE MINICONTTTORI / CONTENTS MINICONTCTORS Criteri di scelta pag. 8 Product selection Caratteristiche tecniche pag. Tecnical data 77 Criteri di scelta
More informationInstallation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201
Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More information34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More information40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52
Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail
More informationThermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More information60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More informationCatalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More information1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting
Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationOnline data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
More informationPCB Relays Twin Relays
Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features - Two separate systems - Lamp applications - Extremely space saving double relay Typical applications
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationTechnical Catalogue. Mini Contactors. Type B 6, B 7
Technical Catalogue Mini Contactors Type B 6, B 7 Mini contactors B 6/4 kw; B 7/5.5 kw Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU Contents Mini contactors
More informationSafety detection solutions
Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking
More informationW DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6
W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationDescription Part-No. Type PU. Nominal voltage DC12V 768001 Relais-SNR 12V 1W 20 DC 24 V 768002 Relais-SNR 24V 1W 20
Replacement relay, 1COcontact, 6 A, : AgSnO 2,AgSnO 2 +5 µm HV Relay with AgSnO 2 Nominal voltage DC12V 768001 Relais-SNR 12V 1W 20 768002 Relais-SNR 24V 1W 20 DC 60 V 768003 Relais-SNR 60V 1W 20 Relay
More informationExample of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More informationABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
More informationEmergency lighting units EM powerled
M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More informationRT series Miniature Printed Circuit Board Relays, Sockets and Accessories
s RT series Miniature Printed Circuit oard Relays, Sockets and ccessories pplied Coil Voltage (% of rated nom.) RT series (DC Coil) 6 mp PC oard Miniature Relay Meets VDE 0mm Spacing, KV Dielectric File
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationGeneral Purpose Relays Accessories. Accessories Miniature Relay PT
Miniature Relay PT n Easy replacement of relays on a densely packed DIN rail n No reduction of protection class or creepage/clearance with plastic retainer n Plug-in indicator- and protection modules n
More informationBETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
More information1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES
POWER RELAY 1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES RoHS compliant FEATURES Ultra slim type with 5 mm thickness Good for high density mounting Low power consumption and high sensitivity Nominal
More informationFieldbus slave modules with I/Os, DIO
140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO
More informationNX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
More informationPreventa Machine Safety Products
Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationMONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA
w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions
More informationType Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC
Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More informationVEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
More informationHYUNDAI U-Series Magnetic Contactor Overload Relay
HHISWCLEB00, 0. Designed by MERMONT Head Office www.hyundaielec.com, Jeonhadong, Donggu, Ulsan, Korea Tel: 0~ Fax: 00 Seoul 0, Gyedong, Jongnogu, Seoul, Korea (Sales & Marketing) Tel:, Fax: Orlando New
More informationPlug-in relays Mini ISO relays
Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of
More informationSmall U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!
4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~
More informationActuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
More informationProduct and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
More informationCatalog EN. Content Transformers for industrial applications
Catalog Ed. 2013 Catalog Content Transformers for industrial applications Technical information 5 Quick product selection card Single and three-phase transformers 6 Quick product selection card Single-phase
More informationTISP4600F3, TISP4700F3 OBSOLETE
*RoHS COMPLIANT TISP4600F3, TISP4700F3 HIGH OLTAGE BIDIRECTIONAL THYRISTOR OEROLTAGE PROTECTORS TISP4600F3, TISP4700F3 Ion-Implanted Breakdown Region Precise and Stable oltage Low oltage Overshoot under
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationThermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
More informationMINI CONTATTORI / MINI CONTACTORS
Informazioni generali / General information pag. 54 Caratteristiche tecniche / Technical datas pag. 57 Codici di ordinazione / Ordering product codes pag. 60 53 CONTTTORI TRIPOLRI CIRCUITO DI COMNDO C..
More informationUncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
More informationG7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm
Slim Plug-In Safety Relay Slim Safety Relay for Machine Control H Slim body only 13 x 24 x 50 mm (six poles) H Four-pole and six-pole models are available H Terminal arrangement simplifies PCB pattern
More informationApplication Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)
Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationPLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet 101780_en_02. 1 Description
PLC INERFCE With PD Relay, niversal Version INERFCE Data Sheet 780_en_02 PHOENIX CONC - 03/08 Description PLC-RS /2 relay modules, which can be used universally, comprise 6.2 mm basic terminal blocks and
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24