Offshore Cables. Basic program - IEC / NEK 606. Productinformation
|
|
|
- Maryann Gibson
- 9 years ago
- Views:
Transcription
1 Offshore Cables Basic program - IEC / NEK 606 Productinformation
2 Dear Customer At Draka we take pleasure in presenting this handbook, which covers the total range of your IEC / NEK 606 offshore (topside) cable needs. The range comprises cables from 60V to 20 kv in applications like counication, data, instrumentation, power and control. The products are subject to continuous research and improvement. The Quality Assurance system is certified by DnV, Det norske Veritas, to be in accordance with ISO 9001 and The FlexFlame is today a multipurpose, all in one, offshore cable with dual compund sheathing making the product resistant to oil, MUD and fire. It is, of course, halogenfree due to environmental care. Cables from Draka are distributed worldwide through our well established network. We aim to provide solutions to suit you special requirements and trust you will find this handbook to be a useful tool in specifying your current and future projects. Yours sincerly Draka
3 Offshore Cables Basic Program - IEC / NEK 606 Index NEK 606 Cable types 4 RFOU(i) 250V, S1/S5 Halogen-free, mud resistant instrumentation cable 5 RFOU(c) 250V, S2/S6 Halogen-free, mud resistant instrumentation cable 10 BFOU(i) 250V, S3/S7 Halogen-free, mud resistant, fire resistant instrumentation cable 14 BFOU(c) 250V, S4/S8 Halogen-free, mud resistant, fire resistant instrumentation cable 19 RU(i) 250V, S11 Halogen-free, unarmoured mud resistant instrumentation cable 23 RU(c) 250V, S12 Halogen-free, unarmoured mud resistant instrumentation cable 26 BU(i) 250V, S13 Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable 29 BU(c) 250V, S14 Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable 32 RFOU 0,6/1kV, P1/P8 Halogen-free, mud resistant power cable 35 RFOU 0,6/1kV, P1/P8, double braided Halogen-free, mud resistant power cable 44 RFOU 0,6/1kV, P1/P8, large single core cables Halogen-free, mud resistant power cable 47 RFOU 6/10(12)kV, P3/P10 Halogen-free, mud resistant HV power cable 50 RFOU 12/20(24)kV, P19/P21 Halogen-free, mud resistant HV power cable 54 BFOU 0,6/1kV, P5/P12 Halogen-free, mud resistant, fire resistant power cable 57 BFOU 0,6/1kV, P5/P12, double braided Halogen-free, mud resistant, fire resistant power cable 65 BFOU 0,6/1kV, P5/P12 Halogen-free, mud resistant, fire resistant power cable, large single core cables 68 UX 1000V, P15 Halogen-free, mud resistant insulated conductor 70 BU 0,6/1kV, P17 Halogen-free, fire resistant, unarmoured, mud resistant power cable 72 RU 0,6/1kV, P18 Halogen-free, unarmoured, mud resistant power cable 76 Approvals 81 Standards and tests 82 Definition of terms 84 Fire, flame, smoke and corrosion test methods 85 Installation recoendations 87 Electrical data 88 Material properties 97 SHF1 versus SHF2 99 Core colours for cables according to NEK Drum capacity in meters 101 Code designation for cables com Subject to change without prior notice 3
4 NEK 606 Cable types List of all the cable types listed in NEK 606 : NEK 2004 Third Edition NEK 606 Code NEK 606 Description Draka Norsk Kabel s cable type Power cables LV and MV P1 P1 / P8 RFOU / TFOU 0,6/1 kv RFOU 0,6/1 kv P2 P2 / P9 RFOU / TFOU 3,6/6(7,2) kv RFOU 3,676(7,2) kv P3 P3/P10 RFOU / TFOU 6/10(12) kv RFOU 6/10(12) kv P4 P4/P11 RFOU / TFOU 8,7/15(17,5) kv RFOU 8,7/15(17,5) kv P5 P5/P12 BFOU 0,6/1 kv BFOU 0,6/1 kv P6 P6/P13 BFOU 3,6/6(7,2) kv - P7 P7/P14 BFOU 6/10(12) kv - P15 UX 0,6/1 kv UX 0,6/1 kv P16 IFLI 250V IFLI 250V P17 BU 0,6/1 kv BU 0,6/1 kv P18 RU 0,6/1 kv RU 0,6/1 kv P19 P19/P21 RFOU / TFOU 12/20(24) kv RFOU 12/20(24) kv P20 P20/P22 RFOU / TFOU 18/30(36) kv RFOU 18/30(36) kv P30 RFOU-HCF / TFOU-HCF 6/10(12) kv RFOU-HCF 6/10(12) kv P31 RFOU-HCF / TFOU-HCF 8,7/15(17,5) kv RFOU-HCF 8,7/15(17,5) kv P32 RFOU-HCF / TFOU-HCF 12/20(24) kv RFOU-HCF 12/20(24) kv P33 RFOU-HCF / TFOU-HCF 18/30(36) kv RFOU-HCF 18/30(36) kv P34 BFOU-HCF 0,6/1 kv BFOU-HCF 0,6/1 kv Instrumentation and telecounication cables S1 S1/S5 RFOU(i) 250V RFOU(i) 250V S2 S2/S6 RFOU(c) 250V RFOU(c) 250V S3 S3/S7 BFOU(i) 250V BFOU(i) 250V S4 S4/S8 BFOU(c) 250V BFOU(c) 250V S9 IYXI(c) 60V - S10 IYOI(c) 60V - S11 RU(i) 250V RU(i) 250V S12 RU(c) 250V RU(c) 250V S13 BU(i) 250V BU(i) 250V S14 BU(c) 250V BU(c) 250V S15 BFOU-HCF(i) 250V BFOU-HCF(i) 250V S16 BFOU-HCF(c) 250V BFOU-HCF(c) 250V Optical Fibre Cable F1 QFCI QFCI F4 QFCI-HCF QFCI-HCF F5 QFCB QFCB F6 AICI AICI Cable types P8 P14, P21 P22, S5 S8 and F5 are to be mud resistant as per NEK com Subject to change without prior notice
5 Halogen-free, mud resistant instrumentation cable RFOU(i) 250V, S1/S5 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 250V EPR/EPR/TCWB/EVA NEK 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 250V Standards applied Application Fixed installation for instrumentation, counication, Control and alarm systems in both EX- and safe areas. Meets the mud resistant requirements in NEK 606. IEC ( ) IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped Pair / Triple / with polyester tape to prevent electrical contact with adjacent pairs/triples. Quad twisting Pairs/triples are identified by numbers printed directly on the insulated conductors. Lay up / Shielding Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "år" DRAKA NORSK KABEL RFOU(i) 250V S1/S5 4 PAIR 0,75 2 IEC IEC ETL Classified No Outer sheath Grey or Blue colour com Subject to change without prior notice 5
6 Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey Range and dimensions Number No of of cores in elements element core,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) ± ± ± ± ± ± ± ± ± ± ± ± ± 19.5 ± ± 19.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 16.5 ± ± 16.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Copper content (kg/km) com Subject to change without prior notice
7 Number No of of cores in elements element core,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 17.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± com Subject to change without prior notice 7
8 Electrical values instrumentation cables Type Capacitance, approx. Inductance, approx, Resistance at 20 C, max. L/R ratio, (nf/km) (mh/km) (Ohm/km) (microh/ohm) Shielded pair 0,75! 110 0,67 24,8 14,3 Shielded triple 0,75! 110 0,67 24,8 14,3 Shielded pair 1,5! 125 0,63 12,2 26,6 Shielded triple 1,5! 125 0,63 12,2 26,6 Shielded pair 2,5! 145 0,59 7,56 39,0 Shielded triple 2,5! 145 0,59 7,56 39,0 Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No RFOU(I) 1PAIR 0.75! S1/S5 GREY Yes RFOU(I) 1PAIR 0.75! S1/S5 BLUE Yes RFOU(I) 2PAIR 0.75! S1/S5 GREY Yes RFOU(I) 2PAIR 0.75! S1/S5 BLUE RFOU(I) 4PAIR 0.75! S1/S5 GREY Yes RFOU(I) 4PAIR 0.75! S1/S5 BLUE RFOU(I) 8PAIR 0.75! S1/S5 GREY Yes RFOU(I) 8PAIR 0.75! S1/S5 BLUE RFOU(I) 12PAIR 0.75! S1/S5 GREY RFOU(I) 12PAIR 0.75! S1/S5 BLUE RFOU(I) 16PAIR 0.75! S1/S5 GREY RFOU(I) 16PAIR 0.75! S1/S5 BLUE RFOU(I) 24PAIR 0.75! S1/S5 GREY RFOU(I) 24PAIR 0.75! S1/S5 BLUE RFOU(I) 1TRIP 0.75! S1/S5 GREY Yes RFOU(I) 1TRIP 0.75! S1/S5 BLUE Yes RFOU(I) 2TRIP 0.75! S1/S5 GREY RFOU(I) 2TRIP 0.75! S1/S5 BLUE RFOU(I) 4TRIP 0.75! S1/S5 GREY RFOU(I) 4TRIP 0.75! S1/S5 BLUE RFOU(I) 8TRIP 0.75! S1/S5 GREY RFOU(I) 8TRIP 0.75! S1/S5 BLUE RFOU(I) 12TRIP 0.75! S1/S5 BLUE RFOU(I) 16TRIP 0.75! S1/S5 GREY RFOU(I) 16TRIP 0.75! S1/S5 BLUE RFOU(I) 19TRIP 0.75! S1/S5 GREY RFOU(I) 24TRIP 0.75! S1/S5 GREY RFOU(I) 24TRIP 0.75! S1/S5 BLUE RFOU(I) 1PAIR! S1/S5 GREY Yes RFOU(I) 1PAIR! S1/S5 BLUE RFOU(I) 2PAIR! S1/S5 GREY RFOU(I) 2PAIR! S1/S5 BLUE RFOU(I) 4PAIR! S1/S5 GREY RFOU(I) 4PAIR! S1/S5 BLUE RFOU(I) 8PAIR! S1/S5 GREY RFOU(I) 8PAIR! S1/S5 BLUE RFOU(I) 12PAIR! S1/S5 GREY RFOU(I) 12PAIR! S1/S5 BLUE RFOU(I) 16PAIR! S1/S5 GREY RFOU(I) 16PAIR! S1/S5 BLUE RFOU(I) 19PAIR! S1/S5 GREY RFOU(I) 19PAIR! S1/S5 BLUE RFOU(I) 24PAIR! S1/S5 BLUE RFOU(I) 32PAIR! S1/S5 GREY RFOU(I) 32PAIR! S1/S5 BLUE com Subject to change without prior notice
9 Part number Description Sheath Colour Stock item EAN No. DNK EL No RFOU(I) 1TRIP! S1/S5 GREY Yes RFOU(I) 1TRIP! S1/S5 BLUE RFOU(I) 2TRIP! S1/S5 GREY RFOU(I) 4TRIP! S1/S5 GREY RFOU(I) 4TRIP! S1/S5 BLUE RFOU(I) 8TRIP! S1/S5 GREY RFOU(I) 8TRIP! S1/S5 BLUE RFOU(I) 12TRIP! S1/S5 GREY RFOU(I) 12TRIP! S1/S5 BLUE RFOU(I) 16TRIP! S1/S5 GREY RFOU(I) 16TRIP! S1/S5 BLUE RFOU(I) 24TRIP! S1/S5 GREY RFOU(I) 24TRIP! S1/S5 BLUE RFOU(I) 1PAIR 2.5! S1/S5 GREY RFOU(I) 2PAIR 2.5! S1/S5 GREY Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice 9
10 Halogen-free, mud resistant instrumentation cable RFOU(c) 250V, S2/S6 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(c) 250V EPR/EPR/TCWB/EVA NEK 606 CodeS2/S6 Operating temperature : 90 C Operating Voltage : 250V Standards applied Application Fixed installation for instrumentation, counication, Control and alarm systems in both EX- and safe areas. Meets the mud resistant requirements in NEK 606. IEC ( ) IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs/triples are identified by numbers printed directly on the insulated conductors. Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "år" DRAKA NORSK KABEL RFOU(c) 250V S2/S6 8 PAIR 0,75 2 IEC IEC ETL Classified No Outer sheath Grey or Blue colour com Subject to change without prior notice
11 Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey Range and dimensions Number No of of cores in elements element core,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± ± ± ± 19.5 ± ± 19.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 16.5 ± ± 16.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± com Subject to change without prior notice 11
12 Number No of of cores in elements element core,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± 19.5 ± ± ± ± ± ± ± ± ± ± ± ± 39.5 ± ± 39.5 ± ± ± ± ± ± ± Electrical values instrumentation cables Capacitance, approx. Type (nf/km) Inductance, approx, (mh/km) Resistance at 20 C, max. (Ohm/km) L/R ratio, (microh/ohm) Unshielded pair 0,75! 100 0,67 24,8 14,3 Unshielded triple 0,75! 100 0,67 24,8 14,3 Unshielded pair 1,5! 110 0,63 12,2 26,6 Unshielded triple 1,5! 110 0,63 12,2 26,6 Unshielded pair 2,5! 125 0,59 7,56 39,0 Unshielded triple 2,5! 125 0,59 7,56 39,0 Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No RFOU(C) 2PAIR 0.75! S2/S6 GREY Yes RFOU(C) 2PAIR 0.75! S2/S6 BLUE Yes RFOU(C) 4PAIR 0.75! S2/S6 GREY Yes RFOU(C) 4PAIR 0.75! S2/S6 BLUE Yes RFOU(C) 8PAIR 0.75! S2/S6 GREY Yes RFOU(C) 8PAIR 0.75! S2/S6 BLUE Yes RFOU(C) 12PAIR 0.75! S2/S6 GREY Yes RFOU(C) 12PAIR 0.75! S2/S6 BLUE RFOU(C) 16PAIR 0.75! S2/S6 GREY Yes RFOU(C) 16PAIR 0.75! S2/S6 BLUE Yes RFOU(C) 19PAIR 0.75! S2/S6 GREY RFOU(C) 24PAIR 0.75! S2/S6 GREY Yes RFOU(C) 24PAIR 0.75! S2/S6 BLUE Yes RFOU(C) 2TRIP 0.75! S2/S6 GREY Yes RFOU(C) 2TRIP 0.75! S2/S6 BLUE Yes RFOU(C) 4TRIP 0.75! S2/S6 GREY RFOU(C) 4TRIP 0.75! S2/S6 BLUE RFOU(C) 8TRIP 0.75! S2/S6 GREY RFOU(C) 8TRIP 0.75! S2/S6 BLUE RFOU(C) 12TRIP 0.75! S2/S6 GREY RFOU(C) 16TRIP 0.75! S2/S6 GREY RFOU(C) 24TRIP 0.75! S2/S6 GREY com Subject to change without prior notice
13 Part number Description Sheath Colour Stock item EAN No. DNK EL No RFOU(C) 24TRIP 0.75! S2/S6 BLUE RFOU(C) 2PAIR! S2/S6 GREY Yes RFOU(C) 2PAIR! S2/S6 BLUE RFOU(C) 4PAIR! S2/S6 GREY Yes RFOU(C) 4PAIR! S2/S6 BLUE RFOU(C) 8PAIR! S2/S6 GREY Yes RFOU(C) 8PAIR! S2/S6 BLUE RFOU(C) 10PAIR! S2/S6 GREY RFOU(C) 12PAIR! S2/S6 GREY RFOU(C) 16PAIR! S2/S6 GREY Yes RFOU(C) 16PAIR! S2/S6 BLUE RFOU(C) 24PAIR! S2/S6 GREY RFOU(C) 32PAIR! S2/S6 GREY RFOU(C) 32PAIR! S2/S6 BLUE RFOU(C) 2TRIP! S2/S6 GREY RFOU(C) 4TRIP! S2/S6 GREY RFOU(C) 8TRIP! S2/S6 BLUE RFOU(C) 12TRIP! S2/S6 GREY RFOU(C) 12TRIP! S2/S6 BLUE RFOU(C) 16TRIP! S2/S6 GREY RFOU(C) 16TRIP! S2/S6 BLUE RFOU(C) 24TRIP! S2/S6 GREY RFOU(C) 24TRIP! S2/S6 BLUE RFOU(C) 4PAIR 2.5! S2/S6 GREY RFOU(C) 4PAIR 2.5! S2/S6 BLUE RFOU(C) 5PAIR 2.5! S2/S6 GREY Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice 13
14 Halogen-free, mud resistant, fire resistant instrumentation cable BFOU(i) 250V, S3/S7 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 250V MGT/EPR/EPR/TCWB/EVA NEK 606 CodeS3/S7 Operating temperature : 90 C Operating Voltage : 250V Application Fixed installation for instrumentation, counication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK 606. Standards applied IEC ( ) IEC class 2 IEC IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped Pair / Triple / with polyester tape to prevent electrical contact with adjacent pairs/triples. Quad twisting Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Lay up / Shielding Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Eg. "meter" "år" DRAKA NORSK KABEL BFOU(i) 250V S3/S7 16 PAIR 0,75 Marking text 2 FLEX - FLAME IEC IEC IEC ETL Classified No Outer sheath Grey or Blue colour com Subject to change without prior notice
15 Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey Range and dimensions Number No of of cores in elements element core,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) ± ± ± ± ± ± ± ± ± 16.5 ± ± 16.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 37.5 ± ± 37.5 ± ± ± ± ± ± ± ± ± ± 19.5 ± ± 19.5 ± Copper content (kg/km) com Subject to change without prior notice 15
16 Number No of of cores in elements element core,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 18.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± 37.5 ± ± 37.5 ± ± ± ± ± ± ± ± ± ± ± ± 18.5 ± ± ± ± ± ± 13.5 ± ± ± com Subject to change without prior notice
17 Electrical values instrumentation cables Type Capacitance, approx. Inductance, approx, Resistance at 20 C, max. L/R ratio, (nf/km) (mh/km) (Ohm/km) (microh/ohm) Shielded pair 0,75! 110 0,67 24,8 14,3 Shielded triple 0,75! 110 0,67 24,8 14,3 Shielded pair 1,5! 125 0,63 12,2 26,6 Shielded triple 1,5! 125 0,63 12,2 26,6 Shielded pair 2,5! 145 0,59 7,56 39,0 Shielded triple 2,5! 145 0,59 7,56 39,0 Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No BFOU(I) 1PAIR 0.75! S3/S7 GREY Yes BFOU(I) 1PAIR 0.75! S3/S7 BLUE Yes BFOU(I) 2PAIR 0.75! S3/S7 GREY Yes BFOU(I) 2PAIR 0.75! S3/S7 BLUE BFOU(I) 4PAIR 0.75! S3/S7 GREY Yes BFOU(I) 4PAIR 0.75! S3/S7 BLUE BFOU(I) 8PAIR 0.75! S3/S7 GREY Yes BFOU(I) 8PAIR 0.75! S3/S7 BLUE BFOU(I) 12PAIR 0.75! S3/S7 GREY BFOU(I) 12PAIR 0.75! S3/S7 BLUE BFOU(I) 16PAIR 0.75! S3/S7 GREY Yes BFOU(I) 16PAIR 0.75! S3/S7 BLUE BFOU(I) 24PAIR 0.75! S3/S7 GREY BFOU(I) 24PAIR 0.75! S3/S7 BLUE BFOU(I) 1TRIP 0.75! S3/S7 GREY Yes BFOU(I) 1TRIP 0.75! S3/S7 BLUE Yes BFOU(I) 2TRIP 0.75! S3/S7 GREY BFOU(I) 2TRIP 0.75! S3/S7 BLUE BFOU(I) 4TRIP 0.75! S3/S7 GREY BFOU(I) 4TRIP 0.75! S3/S7 BLUE BFOU(I) 8TRIP 0.75! S3/S7 GREY Yes BFOU(I) 8TRIP 0.75! S3/S7 BLUE BFOU(I) 12TRIP 0.75! S3/S7 GREY BFOU(I) 12TRIP 0.75! S3/S7 BLUE BFOU(I) 16TRIP 0.75! S3/S7 GREY BFOU(I) 24TRIP 0.75! S3/S7 GREY BFOU(I) 24TRIP 0.75! S3/S7 BLUE BFOU(I) 1PAIR! S3/S7 GREY Yes BFOU(I) 1PAIR! S3/S7 BLUE Yes BFOU(I) 2PAIR! S3/S7 GREY Yes BFOU(I) 2PAIR! S3/S7 BLUE BFOU(I) 4PAIR! S3/S7 GREY Yes BFOU(I) 4PAIR! S3/S7 BLUE BFOU(I) 8PAIR! S3/S7 GREY Yes BFOU(I) 8PAIR! S3/S7 BLUE BFOU(I) 12PAIR! S3/S7 GREY Yes BFOU(I) 12PAIR! S3/S7 BLUE BFOU(I) 16PAIR! S3/S7 GREY Yes BFOU(I) 16PAIR! S3/S7 BLUE BFOU(I) 24PAIR! S3/S7 GREY BFOU(I) 1TRIP! S3/S7 GREY Yes BFOU(I) 1TRIP! S3/S7 BLUE Yes BFOU(I) 2TRIP! S3/S7 GREY BFOU(I) 4TRIP! S3/S7 GREY BFOU(I) 4TRIP! S3/S7 BLUE com Subject to change without prior notice 17
18 Part number Description Sheath Colour Stock item EAN No. DNK EL No BFOU(I) 8TRIP! S3/S7 GREY BFOU(I) 8TRIP! S3/S7 BLUE BFOU(I) 12TRIP! S3/S7 GREY BFOU(I) 12TRIP! S3/S7 BLUE BFOU(I) 16TRIP! S3/S7 GREY BFOU(I) 16TRIP! S3/S7 BLUE BFOU(I) 24TRIP! S3/S7 GREY BFOU(I) 24TRIP! S3/S7 BLUE BFOU(I) 1PAIR 2.5! S3/S7 GREY Yes BFOU(I) 1PAIR 2.5! S3/S7 BLUE BFOU(I) 1PAIR 2.5! BLACK BFOU(I) 2PAIR 2.5! S3/S7 GREY BFOU(I) 4PAIR 2.5! S3/S7 GREY BFOU(I) 16PAIR 2.5! S3/S7 GREY BFOU(I) 1TRIP 2.5! S3/S7 GREY BFOU(I) 8TRIP 2.5! S3/S7 GREY Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice
19 Halogen-free, mud resistant, fire resistant instrumentation cable BFOU(c) 250V, S4/S8 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(c) 250V MGT/EPR/EPR/TCWB/EVA NEK 606 CodeS4/S8 Operating temperature : 90 C Operating Voltage : 250V Standards applied Application Fixed installation for instrumentation, counication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK 606. IEC ( ) IEC class 2 IEC IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Eg. "meter" "år" DRAKA NORSK KABEL BFOU(c) 250V S4/S8 4 PAIR 0,75 Marking text 2 FLEX - FLAME IEC IEC IEC ETL Classified No Outer sheath Grey or Blue colour Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown com Subject to change without prior notice 19
20 Quad Black - Light Blue - Brown - Grey Range and dimensions Number No of of cores in elements element core,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± 14.5 ± ± 14.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± com Subject to change without prior notice
21 Number No of of cores in elements element core,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± 18.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Electrical values instrumentation cables Type Capacitance, approx. Inductance, approx, Resistance at 20 C, max. L/R ratio, (nf/km) (mh/km) (Ohm/km) (microh/ohm) Unshielded pair 0,75! 100 0,67 24,8 14,3 Unshielded triple 0,75! 100 0,67 24,8 14,3 Unshielded pair 1,5! 110 0,63 12,2 26,6 Unshielded triple 1,5! 110 0,63 12,2 26,6 Unshielded pair 2,5! 125 0,59 7,56 39,0 Unshielded triple 2,5! 125 0,59 7,56 39,0 Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No BFOU(C) 2PAIR 0.75! S4/S8 GREY Yes BFOU(C) 2PAIR 0.75! S4/S8 BLUE Yes BFOU(C) 4PAIR 0.75! S4/S8 GREY Yes BFOU(C) 4PAIR 0.75! S4/S8 BLUE Yes BFOU(C) 8PAIR 0.75! S4/S8 GREY Yes BFOU(C) 8PAIR 0.75! S4/S8 BLUE Yes BFOU(C) 12PAIR 0.75! S4/S8 GREY Yes BFOU(C) 12PAIR 0.75! S4/S8 BLUE BFOU(C) 16PAIR 0.75! S4/S8 GREY Yes BFOU(C) 16PAIR 0.75! S4/S8 BLUE Yes BFOU(C) 19PAIR 0.75! S4/S8 GREY BFOU(C) 24PAIR 0.75! S4/S8 GREY Yes BFOU(C) 24PAIR 0.75! S4/S8 BLUE Yes BFOU(C) 2TRIP 0.75! S4/S8 GREY Yes BFOU(C) 2TRIP 0.75! S4/S8 BLUE Yes BFOU(C) 4TRIP 0.75! S4/S8 GREY Yes BFOU(C) 4TRIP 0.75! S4/S8 BLUE BFOU(C) 8TRIP 0.75! S4/S8 GREY BFOU(C) 12TRIP 0.75! S4/S8 GREY BFOU(C) 12TRIP 0.75! S4/S8 BLUE BFOU(C) 16TRIP 0.75! S4/S8 GREY Yes com Subject to change without prior notice 21
22 Part number Description Sheath Colour Stock item EAN No. DNK EL No BFOU(C) 16TRIP 0.75! S4/S8 BLUE BFOU(C) 24TRIP 0.75! S4/S8 GREY BFOU(C) 2PAIR! S4/S8 GREY Yes BFOU(C) 2PAIR! S4/S8 BLUE BFOU(C) 4PAIR! S4/S8 GREY Yes BFOU(C) 4PAIR! S4/S8 BLUE BFOU(C) 8PAIR! S4/S8 GREY Yes BFOU(C) 8PAIR! S4/S8 BLUE BFOU(C) 12PAIR! S4/S8 GREY Yes BFOU(C) 12PAIR! S4/S8 BLUE BFOU(C) 16PAIR! S4/S8 GREY Yes BFOU(C) 16PAIR! S4/S8 BLUE BFOU(C) 24PAIR! S4/S8 GREY Yes BFOU(C) 24PAIR! S4/S8 BLUE BFOU(C) 2TRIP! S4/S8 GREY Yes BFOU(C) 2TRIP! S4/S8 BLUE Yes BFOU(C) 4TRIP! S4/S8 GREY BFOU(C) 4TRIP! S4/S8 BLUE BFOU(C) 8TRIP! S4/S8 GREY Yes BFOU(C) 8TRIP! S4/S8 BLUE BFOU(C) 12TRIP! S4/S8 GREY BFOU(C) 16TRIP! S4/S8 GREY BFOU(C) 24TRIP! S4/S8 GREY BFOU(C) 2PAIR 2.5! S4/S8 GREY BFOU(C) 4PAIR 2.5! S4/S8 GREY BFOU(C) 8PAIR 2.5! S4/S8 GREY BFOU(C) 16PAIR 2.5! S4/S8 GREY BFOU(C) 24PAIR 2.5! S4/S8 GREY BFOU(C) 8TRIP 2.5! S4/S8 GREY BFOU(C) 16TRIP 2.5! S4/S8 GREY Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice
23 Halogen-free, unarmoured mud resistant instrumentation cable RU(i) 250V, S11 Application Fixed installation for instrumentation, counication, Control and alarm systems in both EX- (Zone 2) and safe areas. Meets the mud resistant requirements in NEK 606. Construction Conductor Flame retardant halogen-free instrumentation cable. Mud resistant RU(i) 250V EPR/EVA NEK 606 CodeS11 Operating temperature : 90 C Operating Voltage : 250V Standards applied IEC ( ) - Design IEC class 2 - Conductor IEC Insulation IEC Sheath IEC Flame Retardant IEC Flame Retardant IEC ,2 - Halogen Free IEC ,2 - Low Smoke Code Letter Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Lay up / Shielding Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbers printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour. Outer sheath Marking text Outer sheath colour U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "year" DRAKA NORSK KABEL RU(i) 250V S11 2 pair 0,75 2 IEC IEC Grey or Blue com Subject to change without prior notice 23
24 Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey Range and dimensions Number of elements No of cores in element core,! Conductor, Insulation Thickness, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Electrical values instrumentation cables Capacitance, approx. Inductance, approx, Resistance at 20 C, max. L/R ratio, Type (nf/km) (mh/km) (Ohm/km) (microh/ohm) Shielded pair 0,75! 110 0,67 24,8 14,3 Shielded triple 0,75! 110 0,67 24,8 14,3 Shielded pair 1,5! 125 0,63 12,2 26,6 Shielded triple 1,5! 125 0,63 12,2 26,6 Shielded pair 2,5! 145 0,59 7,56 39,0 Shielded triple 2,5! 145 0,59 7,56 39, com Subject to change without prior notice
25 Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No RU(I) 250V 1PAIR 0.75! S11 GREY RU(I) 250V 1PAIR 0.75! S11 BLUE RU(I) 250V 2PAIR 0.75! S11 GREY RU(I) 250V 2PAIR 0.75! S11 BLUE RU(I) 250V 4PAIR 0.75! S11 GREY RU(I) 250V 8PAIR 0.75! S11 GREY RU(I) 250V 12PAIR 0.75! S11 GREY RU(I) 250V 16PAIR 0.75! S11 GREY RU(I) 250V 24PAIR 0.75! S11 GREY RU(I) 250V 1TRIP 0.75! S11 GREY RU(I) 250V 2TRIP 0.75! S11 GREY RU(I) 250V 4TRIP 0.75! S11 GREY RU(I) 250V 8TRIP 0.75! S11 GREY RU(I) 250V 12TRIP 0.75! S11 GREY RU(I) 250V 16TRIP 0.75! S11 GREY RU(I) 250V 24TRIP 0.75! S11 GREY RU(I) 250V 1PAIR! S11 GREY RU(I) 250V 1PAIR! S11 BLUE RU(I) 250V 2PAIR! S11 GREY RU(I) 250V 2PAIR! S11 BLUE RU(I) 250V 4PAIR! S11 GREY RU(I) 250V 8PAIR! S11 GREY RU(I) 250V 12PAIR! S11 GREY RU(I) 250V 16PAIR! S11 GREY RU(I) 250V 24PAIR! S11 GREY RU(I) 250V 1TRIP! S11 GREY RU(I) 250V 2TRIP! S11 GREY RU(I) 250V 4TRIP! S11 GREY RU(I) 250V 8TRIP! S11 GREY RU(I) 250V 16TRIP! S11 GREY RU(I) 250V 24TRIP! S11 GREY Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice 25
26 Halogen-free, unarmoured mud resistant instrumentation cable RU(c) 250V, S12 Application Fixed installation for instrumentation, counication, Control and alarm systems in both EX- (Zone 2) and safe areas. Meets the mud resistant requirements in NEK 606. Construction Conductor Flame retardant halogen-free instrumentation cable. Mud resistant RU(c) 250V EPR/EVA NEK 606 CodeS12 Operating temperature : 90 C Operating Voltage : 250V Standards applied IEC ( ) - Design IEC class 2 - Conductor IEC Insulation IEC Sheath IEC Flame Retardant IEC Flame Retardant IEC ,2 - Halogen Free IEC ,2 - Low Smoke Code Letter Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs/triples are identified by numbers printed directly on the insulated conductors. Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour. Outer sheath Marking text Outer sheath colour U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "year" DRAKA NORSK KABEL RU(c) 250V S12 2 pair 0,75 2 IEC IEC Grey or Blue com Subject to change without prior notice
27 Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey Range and dimensions Number of elements No of cores in element core,! Conductor, Insulation Thickness, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Electrical values instrumentation cables Capacitance, approx. Inductance, approx, Resistance at 20 C, max. L/R ratio, Type (nf/km) (mh/km) (Ohm/km) (microh/ohm) Unshielded pair 0,75! 100 0,67 24,8 14,3 Unshielded triple 0,75! 100 0,67 24,8 14,3 Unshielded pair 1,5! 110 0,63 12,2 26,6 Unshielded triple 1,5! 110 0,63 12,2 26,6 Unshielded pair 2,5! 125 0,59 7,56 39,0 Unshielded triple 2,5! 125 0,59 7,56 39,0 Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No RU(C) 250V 2PAIR 0.75! S12 GREY RU(C) 250V 4PAIR 0.75! S12 GREY RU(C) 250V 8PAIR 0.75! S12 GREY RU(C) 250V 12PAIR 0.75! S12 GREY RU(C) 250V 16PAIR 0.75! S12 GREY RU(C) 250V 19PAIR 0.75! S12 GREY RU(C) 250V 24PAIR 0.75! S12 GREY com Subject to change without prior notice 27
28 Part number Description Sheath Colour Stock item EAN No. DNK EL No RU(C) 250V 2TRIP 0.75! S12 GREY RU(C) 250V 4TRIP 0.75! S12 GREY RU(C) 250V 8TRIP 0.75! S12 GREY RU(C) 250V 16TRIP 0.75! S12 GREY RU(C) 250V 24TRIP 0.75! S12 GREY RU(C) 250V 2PAIR! S12 GREY RU(C) 250V 4PAIR! S12 GREY RU(C) 250V 8PAIR! S12 GREY RU(C) 250V 12PAIR! S12 GREY RU(C) 250V 12PAIR! S12 BLUE RU(C) 250V 16PAIR! S12 GREY RU(C) 250V 24PAIR! S12 GREY RU(C) 250V 2TRIP! S12 GREY RU(C) 250V 4TRIP! S12 GREY RU(C) 250V 8TRIP! S12 GREY RU(C) 250V 12TRIP! S12 GREY RU(C) 250V 16TRIP! S12 GREY RU(C) 250V 24TRIP! S12 GREY Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice
29 Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(i) 250V, S13 Application Fixed installation for instrumentation, counication, control and alarm systems in both EX-(Zone 2) and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK 606. Construction Conductor Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BU(i) 250V MGT/EPR/EVA NEK 606 CodeS13 Operating temperature : 90 C Operating Voltage : 250V Standards applied IEC ( ) - Design IEC class 2 - Conductor IEC Insulation IEC Sheath IEC Flame Retardant IEC Flame Retardant IEC Fire Resistant IEC ,2 - Halogen Free IEC ,2 - Low Smoke Code Letter Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Lay up / Shielding Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour. Outer sheath Marking text Outer sheath colour U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) "meter" "år" DRAKA NORSK KABEL BU(i) 250V S13 8 PAIR 0,75 2 FLEX - FLAME IEC IEC IEC Grey or Blue com Subject to change without prior notice 29
30 Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey Range and dimensions Number of elements No of cores in element core,! Conductor, Insulation Thickness, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Electrical values instrumentation cables Capacitance, approx. Inductance, approx, Resistance at 20 C, max. L/R ratio, Type (nf/km) (mh/km) (Ohm/km) (microh/ohm) Shielded pair 0,75! 110 0,67 24,8 14,3 Shielded triple 0,75! 110 0,67 24,8 14,3 Shielded pair 1,5! 125 0,63 12,2 26,6 Shielded triple 1,5! 125 0,63 12,2 26,6 Shielded pair 2,5! 145 0,59 7,56 39,0 Shielded triple 2,5! 145 0,59 7,56 39,0 Ordering information com Subject to change without prior notice
31 Part number Description Sheath Colour Stock item EAN No. DNK EL No BU(I) 250V 1PAIR 0.75! S13 GREY BU(I) 250V 1PAIR 0.75! S13 BLUE BU(I) 250V 2PAIR 0.75! S13 GREY BU(I) 250V 2PAIR 0.75! S13 BLUE BU(I) 250V 4PAIR 0.75! S13 GREY BU(I) 250V 8PAIR 0.75! S13 GREY BU(I) 250V 12PAIR 0.75! S13 GREY BU(I) 250V 16PAIR 0.75! S13 GREY BU(I) 250V 24PAIR 0.75! S13 GREY BU(I) 250V 1TRIP 0.75! S13 GREY BU(I) 250V 2TRIP 0.75! S13 GREY BU(I) 250V 4TRIP 0.75! S13 GREY BU(I) 250V 8TRIP 0.75! S13 GREY BU(I) 250V 12TRIP 0.75! S13 GREY BU(I) 250V 16TRIP 0.75! S13 GREY BU(I) 250V 24TRIP 0.75! S13 GREY BU(I) 250V 1PAIR! S13 GREY BU(I) 250V 1PAIR! S13 BLUE BU(I) 250V 2PAIR! S13 GREY BU(I) 250V 2PAIR! S13 BLUE BU(I) 250V 4PAIR! S13 GREY BU(I) 250V 8PAIR! S13 GREY BU(I) 250V 12PAIR! S13 GREY BU(I) 250V 12PAIR! S13 BLUE BU(I) 250V 16PAIR! S13 GREY BU(I) 250V 24PAIR! S13 GREY BU(I) 250V 1TRIP! S13 GREY BU(I) 250V 1TRIP! S13 BLUE BU(I) 250V 2TRIP! S13 GREY BU(I) 250V 4TRIP! S13 GREY BU(I) 250V 8TRIP! S13 GREY BU(I) 250V 12TRIP! S13 GREY BU(I) 250V 16TRIP! S13 GREY BU(I) 250V 24TRIP! S13 GREY BU(I) 250V 1PAIR 2.5! S13 GREY Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice 31
32 Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(c) 250V, S14 Application Fixed installation for instrumentation, counication, control and alarm systems in both EX-(Zone 2) and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK 606. Construction Conductor Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BU(c) 250V MGT/EPR/EVA NEK 606 CodeS14 Operating temperature : 90 C Operating Voltage : 250V Standards applied IEC ( ) - Design IEC class 2 - Conductor IEC Insulation IEC Sheath IEC Flame Retardant IEC Flame Retardant IEC Fire Resistant IEC ,2 - Halogen Free IEC ,2 - Low Smoke Code Letter Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Pair / Triple / Quad twisting Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour. Outer sheath Marking text Outer sheath colour U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) "meter" "år" DRAKA NORSK KABEL BU(c) 250V S14 8 PAIR 0,75 2 FLEX - FLAME IEC IEC IEC Grey or Blue com Subject to change without prior notice
33 Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey Range and dimensions Number of elements No of cores in element core,! Conductor, Insulation Thickness, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± Electrical values instrumentation cables Capacitance, approx. Inductance, approx, Resistance at 20 C, max. L/R ratio, Type (nf/km) (mh/km) (Ohm/km) (microh/ohm) Unshielded pair 0,75! 100 0,67 24,8 14,3 Unshielded triple 0,75! 100 0,67 24,8 14,3 Unshielded pair 1,5! 110 0,63 12,2 26,6 Unshielded triple 1,5! 110 0,63 12,2 26,6 Unshielded pair 2,5! 125 0,59 7,56 39,0 Unshielded triple 2,5! 125 0,59 7,56 39,0 Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No BU(C) 250V 2PAIR 0.75! S14 GREY BU(C) 250V 4PAIR 0.75! S14 GREY BU(C) 250V 8PAIR 0.75! S14 GREY BU(C) 250V 12PAIR 0.75! S14 GREY BU(C) 250V 16PAIR 0.75! S14 GREY BU(C) 250V 19PAIR 0.75! S14 GREY BU(C) 250V 24PAIR 0.75! S14 GREY com Subject to change without prior notice 33
34 Part number Description Sheath Colour Stock item EAN No. DNK EL No BU(C) 250V 2TRIP 0.75! S14 GREY BU(C) 250V 4TRIP 0.75! S14 GREY BU(C) 250V 8TRIP 0.75! S14 GREY BU(C) 250V 12TRIP 0.75! S14 GREY BU(C) 250V 16TRIP 0.75! S14 GREY BU(C) 250V 24TRIP 0.75! S14 GREY BU(C) 250V 2PAIR! S14 GREY BU(C) 250V 4PAIR! S14 GREY BU(C) 250V 8PAIR! S14 GREY BU(C) 250V 12PAIR! S14 GREY BU(C) 250V 16PAIR! S14 GREY BU(C) 250V 24PAIR! S14 GREY BU(C) 250V 2TRIP! S14 GREY BU(C) 250V 4TRIP! S14 GREY BU(C) 250V 8TRIP! S14 GREY BU(C) 250V 12TRIP! S14 GREY BU(C) 250V 16TRIP! S14 GREY BU(C) 250V 24TRIP! S14 GREY Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice
35 Halogen-free, mud resistant power cable RFOU 0,6/1kV, P1/P8 Flame retardant halogen-free power cable. Mud resistant RFOU 0,6/1kV EPR/EPR/TCWB/EVA NEK 606 CodeP1/P8 Operating temperature : 90 C Operating Voltage : 0,6/1kV Standards applied Application Fixed installation for power,control and lighting in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. IEC IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA NORSK KABEL RFOU 0,6/1KV P1/P8 3 x 35/16 2 IEC ETL Classified No Outer sheath colour Black com Subject to change without prior notice 35
36 Core identification power cables Single core Grey (Offwhite) Two cores Grey (Offwhite) - Black Three cores Grey (Offwhite) - Black - Red Four cores Grey (Offwhite) - Black - Red - Blue Five cores Grey (Offwhite) - Black - Red - Blue - Black Above five cores Black numbers on white base Separate earth core Yellow/green G / x in cable description G = one of the core are yellow/green - x = no yellow/green core From Q the core colours on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow Cenelec HD 308S2 colours: Single core Black Two cores Blue - Brown Two cores + earth Blue - Brown - Yellow/green Three cores Brown - Black - Grey Three cores + earth Brown - Black - Grey - Yellow/green Four cores Blue - Brown - Black - Grey Four cores + earth Blue - Brown - Black - Grey - Yellow/green Five cores Blue - Brown - Black - Grey - Black Above five cores Black numbers on white base Range and dimensions Number of elements core,! screen,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Diamete r Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± G ± ± G ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± G ± ± ± ± G ± ± ± ± G ± ± G ± ± ± ± Copper content (kg/km) com Subject to change without prior notice
37 Number of elements core,! screen,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Diamete r Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) ± ± ± ± ± ± ± ± G ± ± ± ± ± ± ± ± ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± ± ± ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± ± ± ± ± ± ± ± ± G ± ± G ± ± Copper content (kg/km) com Subject to change without prior notice 37
38 Number of elements core,! screen,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Diamete r Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± ± ± G ± ± ± ± G ± ± G ± ± ± ± G ± ± ± ± ± ± com Subject to change without prior notice
39 Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No RFOU 0.6/1kV 1X 16/2.5 P1/P8 BLACK RFOU 0.6/1kV 1X 25/4! P1/P8 BLACK RFOU 0.6/1kV 1X 35/6! P1/P8 BLACK RFOU 0.6/1kV 1X 50/6! P1/P8 BLACK RFOU 0.6/1kV 1X 70/6! P1/P8 BLACK RFOU 0.6/1kV 1X 95/10! P1/P8 BLACK RFOU 0.6/1kV 1X 120/10 P1/P8 BLACK RFOU 0.6/1kV 1X 150/10 P1/P8 BLACK RFOU 0.6/1kV 1X 185/10 P1/P8 BLACK RFOU 0.6/1kV 1X 240/16 P1/P8 BLACK RFOU 0.6/1kV 1X 300/16 P1/P8 BLACK Yes RFOU 0.6/1kV 2X /4! P1/P8 BLACK Yes RFOU 0.6/1kV 3G! P1/P8 BLACK RFOU 0.6/1kV 4G! P1/P8 BLACK RFOU 0.6/1kV 3X /4! P1/P8 BLACK Yes RFOU 0.6/1kV 4X /6! P1/P8 BLACK Yes RFOU 0.6/1kV 5X /6! P1/P8 BLACK RFOU 0.6/1kV 7X /6! P1/P8 BLACK Yes RFOU 0.6/1kV 12X /10 P1/P8 BLACK Yes RFOU 0.6/1kV 19X /10 P1/P8 BLACK RFOU 0.6/1kV 27X /10 P1/P8 BLACK RFOU 0.6/1kV 37X /16 P1/P8 BLACK RFOU 0.6/1kV 7G! P1/P8 BLACK RFOU 0.6/1kV 2X 2.5/4! P1/P8 BLACK Yes RFOU 0.6/1kV 3G 2.5! P1/P8 BLACK RFOU 0.6/1kV 3X 2.5/6! P1/P8 BLACK Yes RFOU 0.6/1kV 4G 2.5! P1/P8 BLACK RFOU 0.6/1kV 5G 2.5! P1/P8 BLACK RFOU 0.6/1kV 4X 2.5/6! P1/P8 BLACK Yes RFOU 0.6/1kV 7X 2.5/6! P1/P8 BLACK RFOU 0.6/1kV 12X 2.5/10 P1/P8 BLACK RFOU 0.6/1kV 19X 2.5/10 P1/P8 BLACK RFOU 0.6/1kV 27X 2.5/16 P1/P8 BLACK RFOU 0.6/1kV 7G 2.5! P1/P8 BLACK RFOU 0.6/1kV 2X 4/6! P1/P8 BLACK Yes RFOU 0.6/1kV 3X 4/6! P1/P8 BLACK Yes RFOU 0.6/1kV 4X 4/6! P1/P8 BLACK RFOU 0.6/1kV 5X 4/6! P1/P8 BLACK RFOU 0.6/1kV 3G 4! P1/P8 BLACK RFOU 0.6/1kV 5G 4! P1/P8 BLACK RFOU 0.6/1kV 2X 6/6! P1/P8 BLACK Yes RFOU 0.6/1kV 3X 6/6! P1/P8 BLACK Yes RFOU 0.6/1kV 4X 6/6! P1/P8 BLACK RFOU 0.6/1kV 4G 6! P1/P8 BLACK RFOU 0.6/1kV 3G 6! P1/P8 BLACK RFOU 0.6/1kV 5G 6! P1/P8 BLACK RFOU 0.6/1kV 2X 10/10! P1/P8 BLACK RFOU 0.6/1kV 3X 10/10! P1/P8 BLACK Yes RFOU 0.6/1kV 4X 10/10! P1/P8 BLACK RFOU 0.6/1kV 3G 10! P1/P8 BLACK RFOU 0.6/1kV 5G 10! P1/P8 BLACK RFOU 0.6/1kV 4G 10! P1/P8 BLACK RFOU 0.6/1kV 2X 16/16! P1/P8 BLACK RFOU 0.6/1kV 3X 16/16! P1/P8 BLACK Yes RFOU 0.6/1kV 4X 16/16! P1/P8 BLACK RFOU 0.6/1kV 4G 16! P1/P8 BLACK RFOU 0.6/1kV 5G 16! P1/P8 BLACK RFOU 0.6/1kV 3G 16! P1/P8 BLACK com Subject to change without prior notice 39
40 Part number Description Sheath Colour Stock item EAN No. DNK EL No RFOU 0.6/1kV 2X 25/16! P1/P8 BLACK RFOU 0.6/1kV 3X 25/16! P1/P8 BLACK Yes RFOU 0.6/1kV 4X 25/16! P1/P8 BLACK Yes RFOU 0.6/1kV 4G 25! P1/P8 BLACK RFOU 0.6/1kV 3G 25! P1/P8 BLACK RFOU 0.6/1kV 5G 25! P1/P8 BLACK RFOU 0.6/1kV 2X 35/16! P1/P8 BLACK RFOU 0.6/1kV 3X 35/16! P1/P8 BLACK Yes RFOU 0.6/1kV 4X 35/16! P1/P8 BLACK RFOU 0.6/1kV 4G 35! P1/P8 BLACK RFOU 0.6/1kV 5G 35! P1/P8 BLACK RFOU 0.6/1kV 3X 50/25! P1/P8 BLACK Yes RFOU 0.6/1kV 4X 50/25! P1/P8 BLACK Yes RFOU 0.6/1kV 4G 50! P1/P8 BLACK RFOU 0.6/1kV 5G 50! P1/P8 BLACK RFOU 0.6/1kV 2X 70/35! P1/P8 BLACK RFOU 0.6/1kV 3X 70/35! P1/P8 BLACK Yes RFOU 0.6/1kV 4X 70/35! P1/P8 BLACK RFOU 0.6/1kV 4G 70! P1/P8 BLACK RFOU 0.6/1kV 5G 70! P1/P8 BLACK RFOU 0.6/1kV 5X 70/35! P1/P8 BLACK RFOU 0.6/1kV 2X 95/50! P1/P8 BLACK RFOU 0.6/1kV 3X 95/50! P1/P8 BLACK Yes RFOU 0.6/1kV 4X 95/50! P1/P8 BLACK Yes RFOU 0.6/1kV 4G 95! P1/P8 BLACK RFOU 0.6/1kV 5G 120! P1/P8 BLACK RFOU 0.6/1kV 2X 120/60 P1/P8 BLACK RFOU 0.6/1kV 3X 120/60 P1/P8 BLACK Yes RFOU 0.6/1kV 3X 150/60 P1/P8 BLACK RFOU 0.6/1kV 4X 120/60 P1/P8 BLACK RFOU 0.6/1kV 4G 120! P1/P8 BLACK RFOU 0.6/1kV 3X 185/50 P1/P8 BLACK RFOU 0.6/1kV 4G 150! P1/P8 BLACK RFOU 0.6/1kV 4G 185! P1/P8 BLACK RFOU 0.6/1kV 3X 240/50 P1/P8 BLACK RFOU 0.6/1kV 4G 2402 P1/P8 BLACK RFOU 0.6/1kV 4X 185/95 P1/P8 BLACK RFOU 0.6/1kV 4X 240/120 P1/P8 BLACK com Subject to change without prior notice
41 Electrical values power cables Number of elements core,! screen,! Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC G - STCC G - STCC STCC STCC STCC STCC STCC STCC STCC STCC G - STCC STCC G STCC STCC G STCC G STCC STCC STCC STCC STCC STCC G STCC STCC STCC STCC STCC G 4 - STCC G 4 - STCC STCC STCC STCC G 6 - STCC G 6 - STCC G 6 - STCC STCC STCC STCC G 10 - STCC G 10 - STCC G 10 - STCC STCC STCC com Subject to change without prior notice 41
42 Number of elements core,! screen,! Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC G 16 - STCC G 16 - STCC G 16 - STCC STCC STCC STCC G 25 - STCC G 25 - STCC G 25 - STCC STCC STCC STCC G 35 - STCC G 35 - STCC STCC STCC G 50 - STCC G 50 - STCC STCC STCC STCC G 70 - STCC G 70 - STCC STCC STCC STCC STCC G 95 - STCC G STCC STCC STCC STCC STCC G STCC STCC G STCC G STCC STCC G STCC STCC STCC com Subject to change without prior notice
43 Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice 43
44 Halogen-free, mud resistant power cable RFOU 0,6/1kV, P1/P8, double braided Flame retardant halogen-free power cable. Mud resistant RFOU 0,6/1kV EPR/EPR/TCWB/EVA NEK 606 CodeP1/P8 Operating temperature : 90 C Operating Voltage : 0,6/1kV Standards applied Application Fixed installation for power,control and lighting in both EXand safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. IEC IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape + rubberized Polyamide tape covering Armour/screen O Two layers of tinned copper wire braid (double braid) Tape over armour/screen PET tape + rubberized Polyamide tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "år" DRAKA NORSK KABEL RFOU 0,6/1kV P1/P8 3 x 185/95 2 IEC ETL Classified No Outer sheath colour Black com Subject to change without prior notice
45 Core identification power cables Single core Grey (Offwhite) Two cores Grey (Offwhite) - Black Three cores Grey (Offwhite) - Black - Red Four cores Grey (Offwhite) - Black - Red - Blue Five cores Grey (Offwhite) - Black - Red - Blue - Black Above five cores Black numbers on white base Separate earth core Yellow/green G / x in cable description G = one of the core are yellow/green - x = no yellow/green core From Q the core colours on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow Cenelec HD 308S2 colours: Single core Black Two cores Blue - Brown Two cores + earth Blue - Brown - Yellow/green Three cores Brown - Black - Grey Three cores + earth Brown - Black - Grey - Yellow/green Four cores Blue - Brown - Black - Grey Four cores + earth Blue - Brown - Black - Grey - Yellow/green Five cores Blue - Brown - Black - Grey - Black Above five cores Black numbers on white base Range and dimensions Number of elements core,! screen,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± 59.5 ± ± ± ± ± ± ± Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No RFOU 0.6/1kV 3X 185/95 P1/P8 BLACK RFOU 0.6/1kV 3X 150/70 P1/P8 BLACK RFOU 0.6/1kV 4X 150/70 P1/P8 BLACK RFOU 0.6/1kV 3X 240/120 P1/P8 BLACK Electrical values power cables Number of elements core,! screen,! Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC com Subject to change without prior notice 45
46 Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice
47 Halogen-free, mud resistant power cable RFOU 0,6/1kV, P1/P8, large single core cables Flame retardant halogen-free power cable. Mud resistant RFOU 0,6/1kV EPR/EPR/TCWB/EVA NEK 606 CodeP1/P8 Operating temperature : 90 C Operating Voltage : 0,6/1kV Standards applied Application Fixed installation for power,control and lighting in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. IEC / IEC class 2 IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) Marking text E.g. "meter" "year" DRAKA NORSK KABEL RFOU 0,6/1KV P1/P8 1 x 500/25 2 IEC Outer sheath colour Black com Subject to change without prior notice 47
48 Core identification power cables Single core Grey (Offwhite) Two cores Grey (Offwhite) - Black Three cores Grey (Offwhite) - Black - Red Four cores Grey (Offwhite) - Black - Red - Blue Five cores Grey (Offwhite) - Black - Red - Blue - Black Above five cores Black numbers on white base Separate earth core Yellow/green G / x in cable description G = one of the core are yellow/green - x = no yellow/green core From Q the core colours on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow Cenelec HD 308S2 colours: Single core Black Two cores Blue - Brown Two cores + earth Blue - Brown - Yellow/green Three cores Brown - Black - Grey Three cores + earth Brown - Black - Grey - Yellow/green Four cores Blue - Brown - Black - Grey Four cores + earth Blue - Brown - Black - Grey - Yellow/green Five cores Blue - Brown - Black - Grey - Black Above five cores Black numbers on white base Range and dimensions Number of elements core,! screen,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No RFOU 0.6/1kV 1X 400/25 P1/P8 BLACK RFOU 0.6/1kV 1X 500/25 P1/P8 BLACK RFOU 0.6/1kV 1X 630/25 P1/P8 BLACK Electrical values power cables Number of elements core,! screen,! Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km STCC STCC STCC Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere 690 dc / 670 ac 780 dc / 720 ac 890 dc / 780 ac Short circuit rating 1 second, Ampere com Subject to change without prior notice
49 Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice 49
50 Halogen-free, mud resistant HV power cable, RFOU 6/10(12)kV, P3/P10 Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Construction Conductor Code Letter Flame retardant halogen-free medium voltage (MV) cable. Mud resistant RFOU 6/10(12) kv EPR/EPR/TCWB/EVA NEK 606 CodeP3/P10 Operating temperature : 90 C Operating Voltage : 6/10(12) kv Standards applied IEC Design IEC class 2 - Conductor IEC Insulation IEC Sheath IEC Flame Retardant IEC Flame Retardant IEC ,2 - Halogen Free IEC ,2 - Low Smoke Tinned stranded and compressed copper (STCC), IEC class 2 Conductor screen Semiconductive layer (EP-rubber) semiconductive Insulation R EP-rubber, IEC (EPR) Insulation screen Semiconductive layer (EP-rubber) semicoductive Cores are laid up together. Cores are identified by White, Black or Red Lay up / Shielding threads under and over the metallic screen on each conductor. Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over PET tape armour/screen Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "year" DRAKA NORSK KABEL RFOU 6/10(12)KV P3/P10 Marking text 3 x 95/50 2 IEC Outer sheath colour Red com Subject to change without prior notice
51 Range and dimensions Number of elements core,! screen,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ±1.0 1, , ± ±1.0 1, ± 26.0± ± 28.0 ± ± ± ± ± ± 34.0 ± ± ± ± ± ± 39.0± ± ± ± ± ± 49.5 ± ± 54.5 ± ± 46.0 ± ± 49.5 ± ± 5± ± ± ± ± ± 62.5± ± 66.5 ± ± ± ± 74.0 ± ± 79.5± ± 85.0± com Subject to change without prior notice 51
52 Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No RFOU 6/10KV 1X 16/11! P3/P RED RFOU 6/10KV 1X 25/11! P3/P RED RFOU 6/10KV 1X 35/11! P3/P RED RFOU 6/10KV 1X 50/11! P3/P RED RFOU 6/10KV 1X 70/16! P3/P RED RFOU 6/10KV 1X 95/16! P3/P RED RFOU 6/10KV 1X 120/20! P3/ RED RFOU 6/10KV 1X 150/19! P3/ RED RFOU 6/10KV 1X185/18! P3/P10 RED RFOU 6/10KV 1X 240/21! P3/ RED RFOU 6/10KV 1X 300/29! P3/ RED RFOU 6/10KV 1X 400/35! P3/ RED RFOU 6/10KV 1X 500/40! P3/ RED RFOU 6/10KV 1X 630/40! P3/ RED RFOU 6/10KV 3X 16/32! P3/P RED RFOU 6/10KV 3X 25/31! P3/P RED RFOU 6/10KV 3X 35/35! P3/P RED RFOU 6/10KV 3X 50/31! P3/P RED RFOU 6/10KV 3X 70/35! P3/P RED RFOU 6/10KV 3X 95/50! P3/P RED RFOU 6/10KV 3X 120/60! P3/ RED RFOU 6/10KV 3X 150/75! P3/ RED RFOU 6/10KV 3X 185/45! P3/ RED RFOU 6/10KV 3X 240/53! P3/ RED RFOU 6/10KV 3X 300/55! P3/ RED Electrical values power cables Number Conductor of type 2 elements core,! screen,! Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nf/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC dc / 670 ac STCC dc / 720 ac STCC dc / 780 ac STCC STCC STCC STCC STCC com Subject to change without prior notice
53 Number of elements core,! screen,! Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nf/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC STCC STCC Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 15 x D 9 x D 50 N /! -20 C com Subject to change without prior notice 53
54 Halogen-free, mud resistant HV power cable, RFOU 12/20(24)kV, P19/P21 Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Construction Conductor Code Letter Flame retardant halogen-free medium voltage (MV) cable. Mud resistant RFOU 12/20(24) kv EPR/EPR/TCWB/EVA NEK 606 CodeP19/P21 Operating temperature : 90 C Operating Voltage : 12/20(24) kv Standards applied IEC Design IEC class 2 - Conductor IEC Insulation IEC Sheath IEC Flame Retardant IEC Flame Retardant IEC ,2 - Halogen Free IEC ,2 - Low Smoke Tinned stranded and compressed copper (STCC), IEC class 2 Conductor screen Semiconductive layer (EP-rubber) semiconductive Insulation R EP-rubber, IEC (EPR) Insulation screen Semiconductive layer (EP-rubber) semicoductive Cores are laid up together. Cores are identified by White, Black or Red Lay up / Shielding threads under and over the metallic screen on each conductor. Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over PET tape armour/screen Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "year" DRAKA NORSK KABEL RFOU 12/20(24)KV Marking text P19/P21 3 x 95/50 2 IEC Outer sheath colour Red com Subject to change without prior notice
55 Range and dimensions Number of elements core,! screen,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 65.5 ± ± ± ± 73.5 ± ± ± ± 80.0 ± ± 85.0 ± ± 90.0 ± Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No RFOU 12/20KV 1X 16/13! P19 RED RFOU 12/20KV 1X 25/13! P19 RED RFOU 12/20KV 1X 35/13! P19 RED RFOU 12/20KV 1X 50/15! P19 RED RFOU 12/20KV 1X 70/13! P19 RED RFOU 12/20KV 1X 95/17! P19 RED RFOU 12/20KV 1X120/15! P19 RED RFOU 12/20KV 1X150/15! P19 RED RFOU 12/20KV 1X185/18! P19 RED RFOU 12/20KV 1X240/23! P19 RED RFOU 12/20KV 1X300/28! P19 RED RFOU 12/20KV 3X 16/31! P19 RED RFOU 12/20KV 3X 25/35! P19 RED RFOU 12/20KV 3X 35/35! P19 RED RFOU 12/20KV 3X 50/35! P19 RED RFOU 12/20KV 3X 70/35! P19 RED RFOU 12/20KV 3X 95/50! P19 RED com Subject to change without prior notice 55
56 Part number Description Sheath Colour Stock item EAN No. DNK EL No RFOU 12/20KV 3X120/60! P19 RED RFOU 12/20KV 3X150/75! P19 RED RFOU 12/20KV 3X185/45! P19 RED RFOU 12/20KV 3X240/55! P19 RED Electrical values power cables Number Conductor of type 2 elements core,! screen,! Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nf/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 15 x D 9 x D 50 N /! -20 C com Subject to change without prior notice
57 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1kV, P5/P12 Fire resistant, flame retardant halogen-free power cable. Mud resistant BFOU 0,6/1kV MGT/EPR/EPR/TCWB/EVA NEK 606 CodeP5/P12 Operating temperature : 90 C Operating Voltage : 0,6/1kV Standards applied Application Fixed installation for power, control and lighting in both EXand safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. IEC IEC class 2 IEC IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "år" DRAKA NORSK KABEL BFOU 0,6/1kV P5/P12 3 x 25/16 Marking text 2 FLEX - FLAME IEC IEC ETL Classified No Outer sheath Black colour com Subject to change without prior notice 57
58 Core identification power cables Single core Grey (Offwhite) Two cores Grey (Offwhite) - Black Three cores Grey (Offwhite) - Black - Red Four cores Grey (Offwhite) - Black - Red - Blue Five cores Grey (Offwhite) - Black - Red - Blue - Black Above five cores Black numbers on white base Separate earth core Yellow/green G / x in cable description G = one of the core are yellow/green - x = no yellow/green core From Q the core colours on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow Cenelec HD 308S2 colours: Single core Black Two cores Blue - Brown Two cores + earth Blue - Brown - Yellow/green Three cores Brown - Black - Grey Three cores + earth Brown - Black - Grey - Yellow/green Four cores Blue - Brown - Black - Grey Four cores + earth Blue - Brown - Black - Grey - Yellow/green Five cores Blue - Brown - Black - Grey - Black Above five cores Black numbers on white base Range and dimensions Number of elements core,! screen,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± 15.5 ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± G ± 14.5 ± G ± 15.5 ± ± 14.5 ± ± 15.5 ± ± ± ± ± ± ± ± ± ± ± ± ± com Subject to change without prior notice
59 Number of elements core,! screen,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) 5G ± ± ± ± G ± ± ± ± G ± ± ± ± G ± 16.5 ± ± 16.5 ± G ± ± ± ± ± ± ± ± ± ± ± ± G ± ± G ± ± G ± 19.5 ± ± ± ± ± ± ± G ± ± ± ± ± ± ± 19.5 ± G ± ± G ± 19.5 ± G ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± ± ± com Subject to change without prior notice 59
60 Number of elements core,! screen,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± ± ± ± ± G ± ± G ± ± ± ± ± ± ± ± G ± ± G ± ± ± ± ± ± G ± ± G ± ± ± ± ± ± G ± ± G ± ± G G ± ± ± ± Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No BFOU 0.6/1kV 1X 16/4! P5/P12 BLACK BFOU 0.6/1kV 1X 25/6! P5/P12 BLACK BFOU 0.6/1kV 1X 50/6! P5/P12 BLACK Yes BFOU 0.6/1kV 1X 70/6! P5/P12 BLACK BFOU 0.6/1kV 1X 95/10 P5/P12 BLACK Yes BFOU 0.6/1kV 1X 120/10 P5/P12 BLACK BFOU 0.6/1kV 1X 150/10 P5/P12 BLACK Yes BFOU 0.6/1kV 1X 185/10 P5/P12 BLACK BFOU 0.6/1kV 1X 240/16 P5/P12 BLACK BFOU 0.6/1kV 1X 300/16 P5/P12 BLACK Yes BFOU 0.6/1kV 2X /4 P5/P12 BLACK Yes BFOU 0.6/1kV 3G! P5/P12 BLACK BFOU 0.6/1kV 4G! P5/P12 BLACK BFOU 0.6/1kV 3X /6 P5/P12 BLACK Yes BFOU 0.6/1kV 4X /6 P5/P12 BLACK Yes BFOU 0.6/1kV 5X /6 P5/P12 BLACK com Subject to change without prior notice
61 Part number Description Sheath Colour Stock item EAN No. DNK EL No BFOU 0.6/1kV 7X /6 P5/P12 BLACK Yes BFOU 0.6/1kV 12X /10 P5/P12 BLACK Yes BFOU 0.6/1kV 19X /10 P5/P12 BLACK Yes BFOU 0.6/1kV 27X /16 P5/P12 BLACK BFOU 0.6/1kV 37X /16 P5/P12 BLACK BFOU 0.6/1kV 5G! P5/P12 BLACK BFOU 0.6/1kV 32X /16 P5/P12 BLACK BFOU 0.6/1kV 7G 2.5! P5/P12 BLACK BFOU 0.6/1kV 2X 2.5/6 P5/P12 BLACK Yes BFOU 0.6/1kV 3G 2.5! P5/P12 BLACK Yes BFOU 0.6/1kV 3X 2.5/6 P5/P12 BLACK Yes BFOU 0.6/1kV 4G 2.5! P5/P12 BLACK BFOU 0.6/1kV 4X 2.5/6 P5/P12 BLACK Yes BFOU 0.6/1kV 8G 2.5! P5/P12 BLACK BFOU 0.6/1kV 7X 2.5/6 P5/P12 BLACK Yes BFOU 0.6/1kV 12X 2.5/10 P5/P12 BLACK Yes BFOU 0.6/1kV 19X 2.5/10 P5/P12 BLACK BFOU 0.6/1kV 27X 2.5/16 P5/P12 BLACK BFOU 0.6/1kV 37X 2.5/25 P5/P12 BLACK BFOU 0.6/1kV 5G 2.5! P5/P12 BLACK BFOU 0.6/1kV 4G 4! P5/P12 BLACK BFOU 0.6/1kV 5G 4! P5/P12 BLACK BFOU 0.6/1kV 2X 4/6! P5/P12 BLACK Yes BFOU 0.6/1kV 3X 4/6! P5/P12 BLACK Yes BFOU 0.6/1kV 4X 4/6! P5/P12 BLACK BFOU 0.6/1kV 3G 4! P5/P12 BLACK BFOU 0.6/1kV 2X 6/6! P5/P12 BLACK Yes BFOU 0.6/1kV 3X 6/6! P5/P12 BLACK Yes BFOU 0.6/1kV 4X 6/6! P5/P12 BLACK Yes BFOU 0.6/1kV 3G 6! P5/P12 BLACK BFOU 0.6/1kV 4G 6! P5/P12 BLACK BFOU 0.6/1kV 5G 6! P5/P12 BLACK BFOU 0.6/1kV 2X 10/10 P5/P12 BLACK BFOU 0.6/1kV 3X 10/10 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 10/10 P5/P12 BLACK BFOU 0.6/1kV 3G 10! P5/P12 BLACK BFOU 0.6/1kV 4G 10! P5/P12 BLACK BFOU 0.6/1kV 5G 10! P5/P12 BLACK BFOU 0.6/1kV 2X 16/16 P5/P12 BLACK BFOU 0.6/1kV 3X 16/16 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 16/16 P5/P12 BLACK Yes BFOU 0.6/1kV 3G 16! P5/P12 BLACK BFOU 0.6/1kV 5G 16! P5/P12 BLACK BFOU 0.6/1kV 2X 25/16 P5/P12 BLACK BFOU 0.6/1kV 3X 25/16 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 25/16 P5/P12 BLACK Yes BFOU 0.6/1kV 4G 25! P5/P12 BLACK BFOU 0.6/1kV 5G 25! P5/P12 BLACK BFOU 0.6/1kV 2X 35/16 P5/P12 BLACK BFOU 0.6/1kV 3X 35/16 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 35/16 P5/P12 BLACK BFOU 0.6/1kV 4G 35! P5/P12 BLACK BFOU 0.6/1kV 5G 35! P5/P12 BLACK BFOU 0.6/1kV 3X 50/25 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 50/25 P5/P12 BLACK Yes BFOU 0.6/1kV 5G 50! P5/P12 BLACK BFOU 0.6/1kV 4G 50! P5/P12 BLACK BFOU 0.6/1kV 2X 70/35 P5/P12 BLACK BFOU 0.6/1kV 3X 70/35 P5/P12 BLACK Yes com Subject to change without prior notice 61
62 Part number Description Sheath Colour Stock item EAN No. DNK EL No BFOU 0.6/1kV 4X 70/35 P5/P12 BLACK BFOU 0.6/1kV 4G 70! P5/P12 BLACK BFOU 0.6/1kV 5G 70! P5/P12 BLACK BFOU 0.6/1kV 3X 95/50 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 95/50 P5/P12 BLACK Yes BFOU 0.6/1kV 4G 95! P5/P12 BLACK BFOU 0.6/1kV 5G 95! P5/P12 BLACK BFOU 0.6/1kV 3X 120/60 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 120/60 P5/P12 BLACK BFOU 0.6/1kV 4G 120! P5/P12 BLACK BFOU 0.6/1kV 4G 150! P5/P12 BLACK BFOU 0.6/1kV 4G 150! P5/P12 BLACK BFOU 0.6/1kV 4G 185! P5/P12 BLACK BFOU 0.6/1kV 3X 240/120 P5/P12 BLACK Electrical values power cables Number of elements core,! screen,! Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC G - STCC G - STCC STCC STCC STCC STCC STCC STCC STCC STCC G - STCC STCC G STCC STCC G STCC STCC G STCC STCC G STCC STCC STCC STCC STCC STCC G STCC G 4 - STCC G 4 - STCC com Subject to change without prior notice
63 Number of elements core,! screen,! Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC STCC STCC G 4 - STCC STCC STCC STCC G 6 - STCC G 6 - STCC G 6 - STCC STCC STCC STCC G 10 - STCC G 10 - STCC G 10 - STCC STCC STCC STCC G 16 - STCC G 16 - STCC STCC STCC STCC G 25 - STCC G 25 - STCC STCC STCC STCC G 35 - STCC G 35 - STCC STCC STCC G 50 - STCC G 50 - STCC STCC STCC STCC G 70 - STCC G 70 - STCC STCC STCC G 95 - STCC G 95 - STCC STCC STCC G STCC G STCC G G STCC Ambient temperature correction factors Ambient Temp C Rating factor com Subject to change without prior notice 63
64 Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice
65 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1kV, P5/P12, double braided Fire resistant, flame retardant halogenfree power cable. Mud resistant BFOU 0,6/1kV MGT/EPR/EPR/TCWB/EVA NEK 606 CodeP5/P12 Operating temperature : 90 C Operating Voltage : 0,6/1kV Standards applied Application Fixed installation for power, control and lighting in both EXand safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. IEC IEC class 2 IEC IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner PET tape + rubberized Polyamide tape covering Armour/screen O Two layers of tinned copper wire braid (double braid) Tape over armour/screen PET tape + rubberized Polyamide tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "år" DRAKA NORSK KABEL BFOU 0,6/1kV P5/P12 3 x 25/16 Marking text 2 FLEX - FLAME IEC IEC ETL Classified No Outer sheath Black colour com Subject to change without prior notice 65
66 Core identification power cables Single core Grey (Offwhite) Two cores Grey (Offwhite) - Black Three cores Grey (Offwhite) - Black - Red Four cores Grey (Offwhite) - Black - Red - Blue Five cores Grey (Offwhite) - Black - Red - Blue - Black Above five cores Black numbers on white base Separate earth core Yellow/green G / x in cable description G = one of the core are yellow/green - x = no yellow/green core From Q the core colours on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow Cenelec HD 308S2 colours: Single core Black Two cores Blue - Brown Two cores + earth Blue - Brown - Yellow/green Three cores Brown - Black - Grey Three cores + earth Brown - Black - Grey - Yellow/green Four cores Blue - Brown - Black - Grey Four cores + earth Blue - Brown - Black - Grey - Yellow/green Five cores Blue - Brown - Black - Grey - Black Above five cores Black numbers on white base Range and dimensions Number of elements core,! screen,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± ± ± Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No BFOU 0.6/1kV 3X 150/70 P5/P12 BLACK Yes BFOU 0.6/1kV 4X 150/70 P5/P12 BLACK BFOU 0.6/1kV 4X 185/95 P5/P12 BLACK BFOU 0.6/1kV 3X 185/95 P5/P12 BLACK Electrical values power cables Number of elements core,! screen,! Conductor type Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere KGTFR KGTFR KGTFR KGTFR com Subject to change without prior notice
67 Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice 67
68 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1kV, P5/P12, large single core cables Fire resistant, flame retardant halogen-free power cable. Mud resistant BFOU 0,6/1kV MGT/EPR/EPR/TCWB/EVA NEK 606 CodeP5/P12 Operating temperature : 90 C Operating Voltage : 0,6/1kV Standards applied Application Fixed installation for power, control and lightning in both EXand safe areas, emergency and critical systems where requirement for fire resistance exists. For installations in areas exposed to MUD and drilling/cleaning fluids. IEC IEC class 2 IEC IEC IEC IEC IEC IEC ,2 IEC ,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner PET tape covering Armour/screen O Tinned annealed copper wire braid Tape over armour/screen PET tape Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "år" DRAKA NORSK KABEL BFOU 0,6/1kV P5/P12 3 x 25/16 Marking text 2 FLEX - FLAME IEC IEC ETL Classified No Outer sheath Black colour com Subject to change without prior notice
69 Core identification power cables Single core Grey (Offwhite) Two cores Grey (Offwhite) - Black Three cores Grey (Offwhite) - Black - Red Four cores Grey (Offwhite) - Black - Red - Blue Five cores Grey (Offwhite) - Black - Red - Blue - Black Above five cores Black numbers on white base Separate earth core Yellow/green G / x in cable description G = one of the core are yellow/green - x = no yellow/green core From Q the core colours Cenelec HD 308S2 colours: Single core Two cores Two cores + earth Three cores Three cores + earth Four cores Four cores + earth Five cores Above five cores on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow Black Blue - Brown Blue - Brown - Yellow/green Brown - Black - Grey Brown - Black - Grey - Yellow/green Blue - Brown - Black - Grey Blue - Brown - Black - Grey - Yellow/green Blue - Brown - Black - Grey - Black Black numbers on white base Range and dimensions Number of elements core,! screen,! Conductor, Insulation Thickness, Thickness Inner covering, inner covering, Braid Wire, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No BFOU 0.6/1kV 1X 400/25 P5/P12 BLACK BFOU 0.6/1kV 1X 630/25 P5/P12 BLACK Electrical values power cables Number of elements core,! screen,! Conductor type 2 Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere Short circuit rating 1 second, Ampere STCC " STCC Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice 69
70 Halogen-free, mud resistant insulated conductor UX 1000V, P Flame retardant conductors UX 1000V Halogen-free, NEK 606 Type: P15 Maximum operating Conductor temperature : 90 C Operating voltage : 1000V Application Insulated conductor for earthing and bonding services. Mud resistant in accordance with NEK 606. Standards applied IEC: & NEK 606 IEC: IEC: ,2 IEC: ,2 - Design guidelines - Flame retardance - Halogen-free properties - Smoke density CONSTRUCTION CODE LETTER Conductor Tinned, stranded copper. (1) PETP-tape. (2) Insulation U Flame retardant halogen-free thermoset compound. (3) Unsheathed X Marking E.g; meter year DRAKA NORSK KABEL UX 1000V P15 1x 95! IEC Colour Yellow/green RANGE AND DIMENSIONS: UX 1000V Insulated conductor, P15 Conductor area (!) Conductor diameter approx. () Insulation thickness () over insulation () Weight of conductor approx. (kg/km) Copper content approx. (kg/km) 6 3,15 1,0 5,5±0, ,05 1,0 6,5±0, ,15 1,0 7,5±0, ,4 1,2 9,5±0, ,65 1,2 10,5±1, ,00 1,4 12,5±1, ,85 1,4 14,5±1, ,60 1,6 16,5±1, ,20 1,6 18,0±1, com Subject to change without prior notice
71 150 15,90 1,8 20,0±1, ,70 2,0 22,0±1, ,15 2,2 25,0±1, ,60 2,4 28,0±1, Installation recoendations: In accordance with IEC Minimum bending radius During installation Fixed installed 8 x cable diameter 6 x cable diameter Maximum pulling tension 25N x total cross of conductors Minium installation temperature - 20 C Ordering information: Conductor area (!) DRAKA NORSK KABEL Part number Yellow/green Stock item El-number (Norway only) Yes Yes Yes Yes Yes Yes Yes Yes Yes com Subject to change without prior notice 71
72 Halogen-free, fire resistant, unarmoured, mud resistant power cable, BU 0,6/1kV, P17 Application Fixed installation for power, control and lighting in safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Single core cables are double-insulated battery cables. Construction Conductor Code Letter Fire resistant, flame retardant halogenfree power cable. Mud resistant BU 0,6/1kV MGT/EPR/EVA NEK 606 CodeP17 Operating temperature : 90 C Operating Voltage : 0,6/1kV Standards applied IEC Design IEC class 2 - Conductor IEC Insulation IEC Sheath IEC Flame Retardant IEC Flame Retardant IEC Fire Resistant IEC ,2 - Halogen Free IEC ,2 - Low Smoke Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation B Mica-tape + EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour. Outer sheath Marking text Outer sheath colour U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "år" DRAKA NORSK KABEL BU 0,6/1kV P17 1 x 70 2 IEC IEC Black com Subject to change without prior notice
73 Core identification power cables Single core Grey (Offwhite) Two cores Grey (Offwhite) - Black Three cores Grey (Offwhite) - Black - Red Four cores Grey (Offwhite) - Black - Red - Blue Five cores Grey (Offwhite) - Black - Red - Blue - Black Above five cores Black numbers on white base Separate earth core Yellow/green G / x in cable description G = one of the core are yellow/green - x = no yellow/green core From Q the core colourson RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow Cenelec HD 308S2 colours: Single core Black Two cores Blue - Brown Two cores + earth Blue - Brown - Yellow/green Three cores Brown - Black - Grey Three cores + earth Brown - Black - Grey - Yellow/green Four cores Blue - Brown - Black - Grey Four cores + earth Blue - Brown - Black - Grey - Yellow/green Five cores Blue - Brown - Black - Grey - Black Above five cores Black numbers on white base Range and dimensions Number of elements core,! Conductor, Insulation Thickness, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± ± ± ± ± ± G ± ± ± ± ± G ± ± G ± G ± ± ± G ± ± ± G ± ± ± ± ± com Subject to change without prior notice 73
74 Number of elements core,! Conductor, Insulation Thickness, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No BU 0.6/1kV 1X 16! P17 BLACK BU 0.6/1kV 1X 25! P17 BLACK BU 0.6/1kV 1X 35! P17 BLACK BU 0.6/1kV 1X 50! P17 BLACK BU 0.6/1kV 1X 70! P17 BLACK BU 0.6/1kV 1X 95! P17 BLACK BU 0.6/1kV 1X 120! P17 BLACK BU 0.6/1kV 1X 150! P17 BLACK BU 0.6/1kV 1X 185! P17 BLACK BU 0.6/1kV 1X 10! P17 BLACK BU 0,6/1KV 2X 1,5 MM2 P17 BLACK BU 0.6/1kV 3G! P17 BLACK BU 0,6/1KV 3X 1,5 MM2 P17 BLACK BU 0,6/1KV 7X 1,5 MM2 P17 BLACK BU 0.6/1kV 19X! P17 BLACK BU 0.6/1kV 2X 2.5! P17 BLACK BU 0.6/1kV 3G 2.5! P17 BLACK Yes BU 0,6/1KV 3X 2,5 MM2 P17 BLACK BU 0.6/1kV 4G 2.5! P17 BLACK BU 0.6/1kV 5G 2.5! P17 BLACK BU 0.6/1kV 12X 2.5! P17 BLACK BU 0,6/1KV 3X 4 MM2 P17 BLACK BU 0.6/1kV 3G 4! P17 BLACK BU 0,6/1KV 2X 6 MM2 P17 BLACK BU 0,6/1KV 3X 6 MM2 P17 BLACK BU 0,6/1KV 5G 6! P17 BLACK BU 0,6/1KV 3X 10 MM2 P17 BLACK BU 0,6/1KV 3X 16 MM2 P17 BLACK BU 0,6/1KV 3X 25! P17 BLACK BU 0,6/1KV 3X 35! P17 BLACK BU 0,6/1KV 3X 50! P17 BLACK BU 0,6/1KV 3X 150! P17 BLACK Electrical values power cables Number of elements core,! Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere G Short circuit rating 1 second, Ampere com Subject to change without prior notice
75 Number of elements core,! Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere G G G G G Short circuit rating 1 second, Ampere Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice 75
76 Halogen-free, unarmoured, mud resistant power cable, RU 0,6/1kV, P18 Application Fixed installation for power,control and lighting in both EXand safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Construction Conductor Code Letter Flame retardant halogen-free power cable. Mud resistant RU 0,6/1kV EPR/EVA NEK 606 CodeP18 Operating temperature : 90 C Operating Voltage : 0,6/1kV Standards applied IEC Design IEC class 2 - Conductor IEC Insulation IEC Sheath IEC Flame Retardant IEC Flame Retardant IEC ,2 - Halogen Free IEC ,2 - Low Smoke Tinned annealed stranded circular copper (STCC), IEC class 2 Insulation R EP-rubber, IEC (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour. Outer sheath Marking text Outer sheath colour U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC ) E.g. "meter" "year" DRAKA NORSK KABEL RU 0,6/1KV P18 3 x 2,5 2 IEC Black com Subject to change without prior notice
77 Core identification power cables Single core Grey (Offwhite) Two cores Grey (Offwhite) - Black Three cores Grey (Offwhite) - Black - Red Four cores Grey (Offwhite) - Black - Red - Blue Five cores Grey (Offwhite) - Black - Red - Blue - Black Above five cores Black numbers on white base Separate earth core Yellow/green G / x in cable description G = one of the core are yellow/green - x = no yellow/green core From Q the core colourson RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow Cenelec HD 308S2 colours: Single core Black Two cores Blue - Brown Two cores + earth Blue - Brown - Yellow/green Three cores Brown - Black - Grey Three cores + earth Brown - Black - Grey - Yellow/green Four cores Blue - Brown - Black - Grey Four cores + earth Blue - Brown - Black - Grey - Yellow/green Five cores Blue - Brown - Black - Grey - Black Above five cores Black numbers on white base Range and dimensions Number of elements core,! Conductor, Insulation Thickness, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± ± ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± ± ± ± ± G ± ± G ± ± G ± ± ± G ± ± G ± com Subject to change without prior notice 77
78 Number of elements core,! Conductor, Insulation Thickness, Thickness Outer Sheath, outer sheath, Weight of Cable (Kg/Km) Copper content (kg/km) ± G ± ± G ± ± ± G ± G ± ± ± G ± G ± ± ± G ± G ± G ± ± G ± ± G ± G ± ± G ± ± G ± Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No RU 0.6/1kV 1X 50! P18 BLACK RU 0,6/1KV 1X 70 MM2 P18 BLACK RU 0.6/1kV 1X 95! P18 BLACK RU 0.6/1kV 1X 120! P18 BLACK RU 0.6/1kV 1X 150! P18 BLACK RU 0,6/1KV 1X185 MM2 P18 BLACK RU 0.6/1kV 1X 240! P18 BLACK RU 0.6/1kV 1X 300! P18 BLACK RU 0.6/1kV 2X! P18 BLACK RU 0.6/1kV 3G! P18 BLACK RU 0.6/1kV 3X! P18 BLACK RU 0.6/1kV 4G! P18 BLACK RU 0.6/1kV 4X! P18 BLACK RU 0.6/1kV 7G! P18 BLACK RU 0.6/1kV 5X! P18 BLACK RU 0.6/1kV 7X! P18 BLACK RU 0,6/1KV 12X 1,5 MM2 P18 BLACK RU 0.6/1kV 19X! P18 BLACK RU 0,6/1KV 24X 1,5 MM2 P18 BLACK RU 0.6/1kV 2X 2.5! P18 BLACK RU 0.6/1kV 3G 2.5! P18 BLACK RU 0.6/1kV 3X 2.5! P18 BLACK RU 0.6/1kV 4G 2.5! P18 BLACK RU 0,6/1KV 4X 2,5 MM2 P18 BLACK RU 0.6/1kV 5G 2.5! P18 BLACK RU 0,6/1KV 7X 2,5 MM2 P18 BLACK RU 0,6/1KV 2X 4 MM2 P18 BLACK com Subject to change without prior notice
79 Part number Description Sheath Colour Stock item EAN No. DNK EL No RU 0.6/1kV 3G 4! P18 BLACK RU 0.6/1kV 3X 4! P18 BLACK RU 0.6/1kV 4G 4! P18 BLACK RU 0,6/1KV 4X 4 MM2 P18 BLACK RU 0,6/1KV 5G 4! P18 BLACK RU 0,6/1KV 2X 6 MM2 P18 BLACK RU 0.6/1kV 3G 6! P18 BLACK RU 0,6/1KV 3X 6MM2 P18 BLACK RU 0.6/1kV 4X 6! P18 BLACK RU 0.6/1kV 5G 6! P18 BLACK RU 0.6/1kV 4G 6! P18 BLACK RU 0,6/1KV 2X 10 MM2 P18 BLACK RU 0,6/1KV 3X 10 MM2 P18 BLACK RU 0.6/1kV 4G 10! P18 BLACK RU 0.6/1kV 5G 10! P18 BLACK RU 0,6/1KV 3X 16 MM2 P18 BLACK RU 0,6/1KV 4X 16 MM2 P18 BLACK RU 0.6/1kV 3G 16! P18 BLACK RU 0.6/1kV 4G 16! P18 BLACK RU 0.6/1kV 5G 16! P18 BLACK RU 0,6/1KV 4X 25 MM2 P18 BLACK RU 0.6/1kV 4G 25! P18 BLACK RU 0,6/1KV 2X 35 MM2 P18 BLACK RU 0.6/1kV 4G 35! P18 BLACK RU 0.6/1kV 5G 35! P18 BLACK RU 0,6/1KV 3X 50 MM2 P18 BLACK RU 0.6/1kV 5G 50! P18 BLACK RU 0,6/1KV 3X 70 MM2 P18 BLACK RU 0.6/1kV 5G 70! P18 BLACK Electrical values power cables Number of elements core,! Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere G G G G G Short circuit rating 1 second, Ampere com Subject to change without prior notice 79
80 Number of elements core,! Max. conductor resistance at 20 C, Ohm/km Max. conductor resistance at 90 C, Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC Table B.4, Ampere 5G G G G G G G G G G G G G G G G G Short circuit rating 1 second, Ampere Ambient temperature correction factors Ambient Temp C Rating factor Installation recoendations Minimum Bending Radius during Installation Minimum Bending Radius Fixed Installed Maximum Tensile Load During Installation Minimum Installation Temperature 8 x D 6 x D 50 N /! -20 C com Subject to change without prior notice
81 Approvals Our cables carry these major approvals Det norske Vertitas Germanischer Lloyd American bureau of shipping Lloyds register of shipping ETL Bureau vertias Russian Maritime register of shipping RFOU 250V (c) (i) RU 250V (c) (i) RFOU 0,6/1kV RFOU 6/10kV RFOU 12/20 kv RU 0,6/1kV BFOU 250V (c) (i) BU 250V (i) (c) BFOU 0,6/1kV BU 0,6/1kV BFCU 250V (c) (i) *) BFCU 0,6/1kV *) RFCU 250V (c) (i) *) RFCU 0,6/1kV *) All cables are designed in accordance with IEC , IEC , IEC and IEC except those marked with *). They are designed in accordance with BS com Subject to change without prior notice 81
82 Standards and tests Standards IEC IEC IEC IEC IEC IEC Designation Title Part 350: Shipboard power cables - General construction and test requirements Part 351: Insulating materials for shipboard and offshore units, power, control, instrumentation, telecounication and data cables Part 352: Choice and installation of electrical cables Part 353: Single and multicore non-radial field power cables with extruded solid insulation for rated voltage 1 kv and 3 kv. Part 354: Single -and three-core power cables with extruded solid insulation for rated voltages 6 kv (U m = 7,2kV) up to 30 kv (U m = 36 kv) Part 359: Sheathing materials for shipboard power and telecounication cables. IEC Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) IEC Conductors of insulated cables. IEC Test for electric cables under fire conditions Circuit integrity Part 11 Apparatus Fire alone at a flame temperature of at least 750 C IEC Test for electric cables under fire conditions Circuit integrity Part 12 Apparatus Fire with shock at a flame temperature of at least 830 C IEC Test for electric cables under fire conditions Circuit integrity Part 21 Procedures and requirements Cables of rated voltage up to and including 0,6/1kV IEC Test for electric cables under fire conditions Circuit integrity Part 25 Procedures and requirements Optical fibre cables IEC Test for electric cables under fire conditions Circuit integrity Part 31 Procedures and requirements for fire with shock Cables of rated voltage up to and including 0,6/1kV IEC Test on electric and optical fibre cables under fire conditions. Part 1-1 Test for vertical flame propagation for a single insulated wire or cable - Apparatus IEC Test on electric and optical fibre cables under fire conditions. Part 1-2 Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kw pre-mixed flame IEC Test on electric and optical fibre cables under fire conditions. Part 1-3 Test for vertical flame propagation for a single insulated wire or cable Procedure for determination of flaming droplets/particles IEC Test on electric and optical fibre cables under fire conditions. Part 2-1 Test for vertical flame propagation for a single small insulated wire or cable - Apparatus com Subject to change without prior notice
83 IEC Test on electric and optical fibre cables under fire conditions. Part 2-2 Test for vertical flame propagation for a single small insulated wire or cable Procedure for diffusion flame IEC Tests on electric cables under fire conditions. Part 3-21 Test for vertical flame spread of vertically-mounted bunched wires or cables Category A F/R IEC Tests on electric cables under fire conditions. Part 3-22 Test for vertical flame spread of vertically-mounted bunched wires or cables Category A IEC Tests on electric cables under fire conditions. Part 3-23 Test for vertical flame spread of vertically-mounted bunched wires or cables Category B IEC Tests on electric cables under fire conditions. Part 3-24 Test for vertical flame spread of vertically-mounted bunched wires or cables Category C IEC Tests on electric cables under fire conditions. Part 3-25 Test for vertical flame spread of vertically-mounted bunched wires or cables Category C IEC Power cables with extruded insulation and their accessories for rated voltages from 1 kv (Um = 1,2 kv) up to 30 kv (Um = 36 kv) - Part 1: Cables for rated voltages of 1 kv (Um = 1,2 kv) and 3 kv (Um = 3,6 kv) IEC Test on gases evolved during combustion of electrical cables. Part 1: Determination of the amount of halogen acid gas. IEC Test on gases evolved during combustion of electrical cables. Part 2: Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring ph and conductivity. IEC Coon test methods for insulating and sheathing materials of electric cables. IEC Measurement of smoke density of cables burning under defined conditions. Part 1: Test apparatus. IEC Measurement of smoke density of cables burning under defined conditions. Part 2: Test procedure and requirements. com Subject to change without prior notice 83
84 Definition of terms Flame retardance The cables shall withstand the test specified in IEC Single, earth and bonding wires shall withstand the test specified in IEC Fire resistance Fire resistant cables shall be tested in accordance with IEC and 31. Content of halogen To demonstrate that the cables are halogen-free they shall be tested to IEC ,2 maximum content of halogen = 5 mg/g. Smoke Emission During a cable fire the smoke emission is recoended to have a minimum value of 60% when tested in accordance with IEC Oil resistance For cables with thermoplastic sheath material there are no requirements for oil resistance properties. All thermoset sheathed cables shall be suitable for an oil production installation. The oil resistance properties shall be demonstrated by a test according to IEC SHF-2 with the cable iersed in IRM oil no. 902 at 100 C for 24 hours. Mud resistance In accordance with NEK 606 the mud resistant cables shall have a sheath (SHF Mud) that complies with the requirements in IEC for SHF2 and the below specified. Mud resistant cables shall be designed with sheathing compounds suitable for installation and operation in contact with MUD unless otherwise specified. The MUD resistance test requirements for sheathing compounds SHF Mud are as follows: Test fluid Temperature Duration Mineral oil type IRM 903 Calcium Bromide Brine (Waterbased) Carbo Sea (Oil based) Tensile strength variation Elongation at break variation Volume swell variation Weight increase variation 100 C 7 d 30% 30% 30% 30% 70 C 56 d 25% 25% 20% 15% 70 C 56 d 25% 25% 20% 15% com Subject to change without prior notice
85 Fire, flame, smoke and corrosion test methods Cables' integrity during a fire Fire resistance During a fire it is vital that emergency circuits should continue to function. This could be counication circuits, emergency lights, alarms and fire pumps, etc. On oil rigs and platforms and other confined areas this could be a matter of life and death. Cables that will function in a fire ensuring circuit integrity BFOU / BFCU / BU cables These cable types have Mica tape applied around the conductors which is then insualed with heat-resistant XLPE and have and outer sheathing of a halogen-free thermoplastic material. BXOI cables have between the insualtion and outer sheathing a metal braid armour. Test method IEC C 3 hours. As an option we offer cables to 1000 C for 3 hours with an upgraded IEC test. Flame propagation Flame retardant cables must be self-extinguishing when the source of flames dies out. Flame retardant cables with built-in self-extinguishing properties These cables have sheathing and bedding with hydrated flame retardants that provide resistance to ignition and flame spread. Test methods IEC IEC , category A, B and C. IEC Category Amount of combustible material in litres per metre of cable ladder Burning time Minutes A 7 40 B 3,5 40 C 1,5 20 Smoke risk to personnel Smoke evolution is of major significance in situations where escape routes are limited in the event of fire. Cables having exceptionally low smoke emission All offshore topside cables, halogen-free shipboard cables and fire resistant cables listed in this catalogue, have sheathing and insulation based on halogen-free materials. To minimise the risk of smoke and toxic gases, each component from conductor tapes to outer sheath has been taken into consideration. com Subject to change without prior notice 85
86 Test method 3 m Cube Test for the measurement of smoke density. IEC Damage to expensive equipment Corrosion Halogen-free cables will not cause corrosion to metals. When halogen - containing cables burn, the gases generated in combustion of the sheathing and insulation may cause corrosion. The secondary effects after a fire are often many times larger than the damages caused by the fire itself. Test method IEC IEC com Subject to change without prior notice
87 Installation recoendations The following installation recoendations are in accordance with IEC regulations and practice. Different regulations may apply in other countries. Minimum cable bending radius. Cables for rated voltages up to 0,6/1 kv, in accordance with IEC Outer diameter Minimum bending radius when fixed installed of cable Unbraided cables Braided cables D < 25 4D 6D D > 25 6D 6D Minimum bending radius during installation 8D 8D Medium voltage cables up to and including 12/20(24) kv: Minimum bending radius during installation: Minimum bending radius when fixed installed: 15D 9D Installation temperature. Minimum recoended installation temperature for cables of rated voltage up to 20 kv, such as: RFOU BFOU RU BU -20 C Pulling tension. The cable pulling tension during installation can be estimated by means of the following formula: p = 50 N! total cross of conductors in the armoured cable or p = 25 N! total cross of conductors in the unarmoured cable Additional tension will be supplied from the braid and the insulation and sheathing compound. com Subject to change without prior notice 87
88 Electrical data Conductor Resistance Resistance formula: L R = p! A R = resistance in ohm per phase Ohm 2 p = specific resistance!!!!!!! m A = conductor area!, L = conductor length, m Resistance as a function of temperature: R = R 0 (1 + " (t-20 C)) R = Resistance at t=20 C, t = conductor temperature C, " = 0,00393 for copper Conductor resistance tinned annealed copper 250V, 0,6/1kV, 1,8/3(3,6)kV. In accordance with IEC 60228, class 2. Tinned stranded annealed copper conductors for single core and multi-core cables 250V, 0,6/1kV and 1,8/3kV Nominal conductor area! No. of wires and diameter of wires diam. Ø Max. resistance pr km 20 C 90 C ohm ohm 0,5 7x 0,30 0,9 36,7 46,8 0,75 7x 0,37 1,1 24,8 31,6 1 7x 0,43 1,3 18,2 23,2 1,5 7x 0,53 1,6 12,2 15,6 2,5 7x 0,67 2,0 7,56 9,64 4 7x 0,85 2,6 4,70 5,99 6 7x 1,05 3,2 3,11 3, x 1,35 4,1 1,84 2, x 1,71 5,2 1,16 1, x 2,13 6,6 0,734 0, x 1,53 7,7 0,529 0, x 1,80 9,1 0,391 0, x 2,17 10,9 0,270 0, x 1,80 12,6 0,195 0, x 2,03 14,2 0,154 0, x 2,27 15,9 0,126 0, x 2,52 17,7 0,100 0, x 2,24 20,2 0,0762 0, x 2,52 22,6 0,0607 0, x 2,36 26,0 0, , x 2,64 29,0 0,0369 0, x 2,52 32,8 0,0286 0,0359 Conductor resistance, tinned annealed copper conductor com Subject to change without prior notice
89 3,6/6(7,2)kV, 6/10(12)kV, 8,7/15(17,5)kV, 12/20(24)kV and 18/30(36)kV. In accordance with IEC 60228, class 2. Compressed tinned stranded annealed copper conductors for single core and multicore cables 3,6/6kV, 6/10kV, 8,7/15kV, 12/20(24)kV and 18/30(36)kV. Nominal conductor area! No. of wires and diameter of wires *) diam. Ø Max. resistance pr km 20 C 90 C ohm ohm 16 7x 1,71 5,2 1,16 1, x 2,14 6,5 0,734 0, x 1,53 7,4 0,529 0, x 1,80 8,8 0,391 0, x 2,17 10,3 0,270 0, x 1,80 12,1 0,195 0, x 2,03 13,6 0,154 0, x 2,27 15,1 0,126 0, x 2,52 16,8 0,100 0, x 2,24 19,1 0,0762 0, x 2,52 21,5 0,0607 0,0774 *) of wires before compressing com Subject to change without prior notice 89
90 Wire gauge conversion table US Standard cross- to square millimetres U.S. Standard Equivalent cross-! Nearest available cross-! 20 AWG / / / / MCM com Subject to change without prior notice
91 Current ratings for 250V and 0,6/1kV cables in fixed installations. Current carrying capacities in continuous service at maximum rated temperature of 90 C. In accordance with IEC (2005) Annex B, Table B.4. Ambient temperature 45 C Conductor area! 1-core Amp 2-core Amp 3-4 core Amp , , For cables with more than 4 cores, the current ratings are given by the following formula: I 1 I = " 3 $ N I 1 = current rating for single core N = number of cores No. of cores 1,5! Amp 2,5! Amp com Subject to change without prior notice 91
92 Current rating for 1,8/3(3,6)kV, 3,6/6(7,2)kV, 6/10(12)kV, 8,7/15(17,5)kV, 12/20(24)kV and 18/30(36)kV cables in fixed installations. Current carrying capacities in continuous service at maximum rated temperature of 90 C. In accordance with IEC (2005) Annex B, Table B.4. Conductor area! 1-core Amp 2-core Amp 3-4 core Amp The tabled current ratings must be adjusted for ambient air temperatures other than 45 C. Appropriate rating factors are: Ambient air temp. C Rating factors 1,10 1,05 1,00 0,94 0,88 0,82 0,74 0,67 0,58 0, com Subject to change without prior notice
93 Short circuit ratings The following short circuit currents are for cables normally operating at a maximum conductor temperature of 85 C. The theoretical temperature that arises in the conductor during a short circuit, which is used as a basis of the calculation, is 250 C. EPR and XLPE insulation are capable of withstanding short term temperatures up to 250 C.The short circuit currents for copper conductors given in the table are values for one second, for other durations the current may be calculated from the following formula: I I t = " $t I t = short ciricut current for t sec. (Amp), l = short circuit current for one sec. (Amp), t = short circuit duration (sec.) The duration of the short circuit based on these assumptions should be between 0,2 sec. and 5 sec. Conductor area! Current 1 second amperes Conductor area! Current 1 second amperes 1, , , Reactance The reactance of a cable operating in an AC system depends on many factors, including, in particular, the axial spacing between conductors and the proximity and magnetic properties of adjacent steelwork. The former is known for multicore cable, but may vary for single core cables depending upon the spacing between them and their disposition when installed. Reactance of cables in certain disposition when installed. Reactance of cables in certain dispositions remote from steelwork are calculable and are shown. The tabulated values are for cables with circular conductors. The value for a sector-shaped conductor should be taken as 90% of the calculated value. Induction for 2-, 3- and 4- conductor cables is given by the formula: 2a L = 0,2 * ( In ( " ) + 0,25 ) * 10-6 d L = Induction in H/m and phase, a = Axial space between conductors in. d = conductor diameter in. Reactance for 2-, 3- and 4-conductor cables is given by the formula: X = 2 * % * f * L * I X = Reactance in ohm pr. Phase, f = frequency in Hz, L = Induction in H/m and phase I = Conductor length in meter. com Subject to change without prior notice 93
94 Reactance Values for Cables Power and control cables. RFOU 0,6/1 kv 2-, 3- and 4 cores ohm/km 1- core* ohm/km! 60 Hz 50 Hz 60 Hz 50 Hz 1,5 0,132 0,110 2,5 0,123 0, ,115 0, ,108 0, ,101 0, ,096 0,080 0,139 0, ,095 0,079 0,134 0, ,092 0,076 0,127 0, ,092 0,076 0,123 0, ,091 0,075 0,120 0, ,088 0,073 0,116 0, ,086 0,072 0,113 0, ,087 0,072 0,110 0, ,086 0,072 0,109 0, ,086 0,072 0,109 0, ,086 0,071 0,107 0,089 *) Reactance for 1-conductor cables given at Three- foil formation Power and control cables, BFOU 0,6/1 kv. - 2-, 3- and 4 core ohm/km 1- core* ohm/km! 60 Hz 50 Hz 60 Hz 50 Hz 1,5 0,138 0,115 2,5 0,129 0, ,120 0, ,112 0, ,105 0, ,099 0,082 0,144 0, ,098 0,081 0,135 0, ,094 0,078 0,129 0, ,093 0,078 0,125 0, ,092 0,077 0,121 0, ,090 0,075 0,117 0, ,088 0,073 0,112 0, ,088 0,073 0,112 0, ,088 0,073 0,109 0, ,087 0,072 0,109 0, ,086 0,072 0,108 0,090 *) Reactance for 1-conductor cables given at Three- foil formation com Subject to change without prior notice
95 ! 50 Hz 60 Hz 50 Hz 60 Hz *) Reactance for 1-conductor cables given at Three- foil formation Medium Voltage Power cables. RFOU 6/10 kv 3 core ohm/km 1- core* ohm/km Medium Voltage Power cables. RFOU 12/20(24)kV. 3 core ohm/km 1-core* ohm/km! 50 Hz 60 Hz 50 Hz 60 Hz *) Reactance for 1-conductor cables given at Three- foil formation Impedance Induction for 2-, 3- and 4- conductor cables is given by the formula: Z = $ ( R 2 + X 2 ) Z = Impedansce in ohm pr. phase, R = Resistance at operating temprature in ohm pr. phase. X = Reactance in ohm pr. phase. Electrical characteristics for instrumentation and telecounication cables such as 250 V cables: RFOU and BFOU according to IEC com Subject to change without prior notice 95
96 Cables with collective screen Type Capacitance, approx. Inductance, approx, Resistance at 20 C, max. L/R ratio, (nf/km) (mh/km) (Ohm/km) (microh/ohm) Unshielded pair 0,75! 100 0,67 24,8 14,3 Unshielded triple 0,75! 100 0,67 24,8 14,3 Unshielded pair 1,5! 110 0,63 12,2 26,6 Unshielded triple 1,5! 110 0,63 12,2 26,6 Unshielded pair 2,5! 125 0,59 7,56 39,0 Unshielded triple 2,5! 125 0,59 7,56 39,0 Cables with individually screened pair/triples Type Capacitance, approx. Inductance, approx, Resistance at 20 C, max. L/R ratio, (nf/km) (mh/km) (Ohm/km) (microh/ohm) Shielded pair 0,75! 110 0,67 24,8 14,3 Shielded triple 0,75! 110 0,67 24,8 14,3 Shielded pair 1,5! 125 0,63 12,2 26,6 Shielded triple 1,5! 125 0,63 12,2 26,6 Shielded pair 2,5! 145 0,59 7,56 39,0 Shielded triple 2,5! 145 0,59 7,56 39, com Subject to change without prior notice
97 Material properties Polymeric materials used in cables for ships and offshore topside installations For 25 years Draka Norsk Kabel has been facing the same challenge : The increasing severe performance criteria demands from our ship and offshore customers. Elastomers are the major part of our cable construction. The insulation, bedding and sheathing have been developed through intensive research and development to meet the offshore and ship industry's specific and stringent requirements. This information is not intended to give you details of the elastomers in use. For correct selection and application of materials our technical representatives will be pleased to provide you with more complete information. EP - rubber (EPDM) EPDM is a hydrocarbon rubber that combines electrical performance suitable for fire resistant offshore cables with mechanical toughness and resistance to ozone, UV light and heat. It's wet electrical properties are unique. Applications : Wire insulation Bedding compounds Flame retardant halogen-free termoset compound (EVA) EVA, ethylene vinyl acetate, is a multi-functional elastomer, which resists the combined deteriorating influences of heat, oil and weather. (In accordance with IEC type SHF2). For offshore applications, EVA can be compounded to produce high quality cable sheathing with low smoke and flame propagation, and with no emission of halogenous acids. Applications : Cable sheathing on offshore oil platforms, ships, hotels and in rooms with expensive equipment, which must not be subjected to corrosion damage. Low smoke, Flame retardant, Halogen-free and Thermoplastic compounds, HFFR. When PVC is not acceptable due to the problems chlorine (halogen) containing materials present in the event of a fire HFFR must be used. (In accordance with IEC type SHF1). Our HFFR materials will not propagate a fire along a cable run, drip or give off black smoke. No acid gases will be released during a fire that can corrode and damage expensive equipment. Applications: Cable sheating for Rooms with IT equipment high - rise buldings (hotels) hospitals Telephone exchanges subway systems, airports and many others. XLPE linked Polyethylene Polyethylene is the most used plastic material. By introducing chemical bonding between the chains in PE we get XLPE, a thermoset type of PE. In cable insulation it is used for the excellent insulation properties, very good mechanical com Subject to change without prior notice 97
98 strength, low density and good thermal stability. Applications : Wire insulations Physical and chemical properties of Draka's sheathing compounds for use in offshore topside and shipboard cables Enhanced oil resistant EVA (SHF2) NITRILE/PVC PVC HFFR (SHF1) Mechanical properties Weathering (O 2 -O 3 ) Heat resistance Low temperature Hydrocarbons general Hydrocarbons high aromatic (MUD) 3-4 * Sea-water Fire resistant Oxygen Index 4(35) 3(28) 4(32) 4(35) Smoke generation Halogens No CI CI No 5 - Excellent, 4 - Very good, 3 - Good, 2 - Medium, 1 - Poor, 0 - Not recoended * Drilling MUD is not one chemical, but a mix of different chemicals and each producer have their own composition. The sheathing material could be resistant to the aromatics in the MUD, but be affected by uther chemicals like corrosion inhibitors. Each MUD must therefore be tested for compatibility with the cable sheathing. The test method for this MUD test is descriebed in NEK 606: 2004 Third edition com Subject to change without prior notice
99 SHF1 versus SHF2 The table below addresses only some main characteristics differences. For complete information see IEC Type of material SHF1 Halogen-free Thermoplastic SHF2 Halogen-free Elastomeric or thermosetting material Some main characteristics Mechanical characteristics after iersion in hot oil (IEC , clause 10)* * If oil resistance is required for a halogen-free compound, SHF 2 compound is recoended. Hot set test (IEC , clause 9) Pressure test at high temperature IEC , subclause 8.2) Heat shock test (IEC , subclause 9.2) No requirements No requirements 80 C, 4-6 min under load depending on cable diameter: 50% Maximum permissible deformation 100 C for 24 hours: ±40% maximum variation in tensile strength: ±40% maximum variation in elongation at break 200 C, 15 min time under load with 20 (N/!) mechanical stress: 175% Maximum elongation under load 25% Maximum permanent elongation after cooling No requirements 150 C) 1h duration: No requirements Ozone resistance test IEC , clause 8 (Alternative test method may be used in some countries for legal reasons) No requirements 25 ± 2 C for 24 h: Max 0,025 to 0,030 % ozone concentration (in volume) com Subject to change without prior notice 99
100 Core colours for cables according to NEK 606 Please look at the actual page for each cable type. Instrumentation and counications cable for fixed installation (conductor size from 0,75! and above) such as RFOU, BFOU, RU and BU 250V. Pair: Triple: Black -- Light blue Black -- Light blue - Brown Pairs and triples are identified by numbered tape with printed black numbers or by numbers printed directly on the insulated conductors. Power and control cables for fixed installation, such as RFOU, BFOU, RU and BU 0,6/1kV 1-core : Off-white 2-cores: Off-white - Black 3-cores: Off-white - Black - Red 4-cores: Off-white - Black - Red - Blue 5-cores: Off-white - Black - Red - Blue - Black Above 5-cores : Black numbers on white base. Separate earth conductor (if any): Yellow/green. From Q the core colours on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow Cenelec HD 308S2 colours: One core: Two cores: Two cores + earth Three cores: Three cores + earth Four cores: Four cores + earth Five cores Above 5-cores : Black Blue Brown Blue Brown Yellow/green Brown - Black Grey Brown - Black Grey Yellow/green Blue - Brown - Black Grey Blue - Brown - Black Grey Yellow/green Blue - Brown - Black Grey - Black Black numbers on white base. Medium Voltage cables for fixed installation, RFOU 1-core : Off-white insulation + black semi-conductive layer. 3-cores : Off-white insulation + black semi-conductive layer identified by White-Black-Red threads under and over the metallic screen on each individual core. Separate earth conductor (if any): Yellow/green com Subject to change without prior notice
101 Drum capacity in meters Free space Drum No: R5 R6 R6T R8 R9 R10 R10A R11 R12 R14 R14A R16 R16A R18 R20 R22 R24 R26 Overall cable diam. Free space Drum No: Overall cable diam com Subject to change without prior notice 101
102 com Subject to change without prior notice
103 Code designation for cables A cable code of 2-4 letters is used to descriebe the construction. Additional abbrevation for instrumentation cables: Collective screen = (c) Individual pair or triple screen = (i) The interpretation ( per letter) can be read from the table below: 1st. letter: Insulation 2nd. letter Bedding / inner sheath 3rd. letter Armouring / screen 4th. letter Outer sheath A Fibre, tight cladded B Fire resistant tape + insulation (Halogen-free) C Polychloroprene (Neoprene) PCP, or chlorinated polyethylene - CPE D Impregnated paper Drip free E Polyethylene - PE Polypropylene - PP F PE or PP + filling compound G Polyamid - PA H Chlorosulphonated polyethylene - CSP I Thermoplastic compound (Halogen-free) K Paper L Air + plastics (Coaxial cable) M Expanded PE or PP + filling compound N Impregnated paper O Impregnated paper, oilfilled cable P Polyvinylchloride - PVC Q Fibre in loose tube R Ethylenepropylene rubber - EPR S Silicone rubber T -linked polyethylene XLPE U Halogen-free thermoset compound EMA or EVA V Fibre, slotted core W Other materials X No insulation Y Z Flour plastics PTFE / FEP A Aluminium (optional with corrosion protection) B Corrogated aluminium (o.w.c.p.) C Polychloroprene (Neoprene) PCP, or chlorinated polyethylene - CPE D Aluminium + Plastics E Polyethylene - PE Polypropylene - PP F Bedding or taping (Halogen-free) G H Chlorosulphonated polyethylene - CSP I Thermoplastic compound (Halogen-free) K Lead L Aluminium laminate + plastics sheath M Polyester N Polyurethane O Lead + Plastics P Polyvinylchloride - PVC Q R Ethylenepropylene rubber - EPR S Bedding or taping + concentric conductor T PE + aluminium wire + steel tape U Halogen-free thermoset compound EMA or EVA V Aluminium screen Other materials W X No bedding or equivalent Y Screen Z Flour plastics A Strength member yarn B Steel tapes, 2 off C Galvanized steel wire braid D Oil filled cable reinforcement (Longitudinal / Transverse) E Oil filled cable reinforcement (Transverse only) F Flat steel wire armour G H Steel tape + steel wires I Steel tapes, 4 off K Steel wire, plastics or rubber coated L Aluminium (laminated to outer jacket) M N Steel (laminated to outer jacket) O Copper wire braid (Tinned or bare) P Phosphorbronze wire braid Q Steel wires + counter steel tape (optional) R Steel wires (round) + filling compound S Concentric conductor (Screen) T U V Double wire armour (two layers) W Catenary wire X No armour Y Z A Yarn + bitumen B Hydrocarbon resistant sehath C Polychloroprene (Neoprene) PCP, or chlorinated polyethylene - CPE D E Polyethylene - PE Polypropylene - PP F Semi-conducting PE G PE + PA H Chlorosulphonated polyethylene - CSP I Thermoplastic compound (Halogen-free) K Lead L M Polyester N Polyurethane O P Polyvinylchloride - PVC Q R Ethylenepropylene rubber - EPR S Silicone rubber T -linked polyethylene XLPE U Halogen-free thermoset compound EMA or EVA V Other halogen-free thermoset materials W Other materials X No sheath Y Z Flour plastics
104 Approvals Our cables carry these major approvals Det norske Vertitas Germanischer Lloyd American bureau of shipping Lloyds register of shipping ETL Bureau vertias Russian Maritime register of shipping RFOU 250V (c) (i) RU 250V (c) (i) RFOU 0,6/1kV RFOU 6/10kV RFOU 12/20 kv RU 0,6/1kV BFOU 250V (c) (i) BU 250V (i) (c) BFOU 0,6/1kV BU 0,6/1kV BFCU 250V (c) (i) *) BFCU 0,6/1kV *) RFCU 250V (c) (i) *) RFCU 0,6/1kV *) All cables are designed in accordance with IEC , IEC , IEC and IEC except those marked with *). They are designed in accordance with BS 6883 Draka in Norway VISITORADDRESS: Kjerraten 16 N-3013 Draen Norway SWITCHBOARD: Telephone: Fax: Draka Norsk Kabel AS DRAMMEN (Factory): PO Box 369 Bragernes N-3001 Draen Norway HOKKSUND (Warehouse): Loesmoen 3300 Hokksund Norway
FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.
OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
CAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376
T o t a l S o l u t i o n o f M a r i n e C a b l e Marine & Shipboard Cable JIS C 3410(1999) IEC 60092-350, 353, 354, 376 Marine & Shipboard cable Total Solution of Marine Cable JIS C 3410(1999), IEC
6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
Global cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
VIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
Fire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
FIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
Outside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
CONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
MEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
International Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
www.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
The Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 [email protected] www.leoni-infrastructure-datacom.com
100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
with coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
VDE-approved PVC-Control Cables
Works photo: HELUKAEL VDE-approved PVC-Control Cables VDE-approved PVC-Control Cables This certification/licency is issued according to the rules of the HAR Agreement, wherein the certification/ licency
BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
Power and Wiring Cables
1 Single-Core PVC 1X...................... 1: Single-Core PVC/PVC 1Y.................. 1: Flat Twin & Flat Three Core PVC /Y........ 1: Multicore XLPE/LSF/SWA/LSF BS Control Cable.............................
Festoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10
CONTENT General < The Company..................................................................................... 3 Customized cables for different applications < Data / POF Cables POF-LWL and hybrid
Fibre optic cables MDIC LSZH
MDIC LSZH MDIC LSZH - Indoor Access Cable. Micro Drop Installation Cable, special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy
Technical cable guide
Technical cable guide November 2014 One stop-shop for all your cable needs Welcome to the latest edition of the Technical Cable Guide. Following the recent acquisition of Draka, the Prysmian Group is now
Temperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts
Airfield Cables Issue 10/2003 Piktogramme Temperature Permissible ambient temperature Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance
Flexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
MEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
DATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
KNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
Standard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
David O Brien, CMP Products ([email protected])
David O Brien, CMP Products ([email protected]) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?
Section 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
PVC YALITIMLI SÝNYAL VE KONTROL KABLOLARI PVC INSULATED SIGNAL AND CONTROL CABLES (VDE 0812-VDE 0814-VDE 0245)
LÝYY KABLO YAPISI: CONSTRUCTION: 1- ÝLETKEN : IEC-228 ;DIN VDE 0295;HD 383 SINIF-5 ELEKTROLÝTÝK BÜKÜLÜ BAKIR 2- YALITKAN : DIN VDE 0207 BÖLÜM-4 YI2 PVC KOMPAUND 3- YALITIM RENK : DIN 47100 4- BÜKÜM : UYGUN
Exane 125 Drilling Rig and Commercial Marine Cable
Exane 125 Drilling Rig and Commercial Marine Cable Over 20 Years of Superior Perfomance On Oil Rigs Around The World Engineered Wire & Cable for Demanding Applications Certified as Type P per IEEE-45 STD
KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
Specializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
COAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
ETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES
Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING
LOW VOLTAGE POWER CABLES
LOW VOLTAGE POWER CABLES CONTENTS 1 4 GENERAL INTRODUCTION TECHNICAL BARE SOFT DRAWN STRANDED CONDUCTORS 38 39 44 48 52 53 56 59 60 63 68 72 75 76 79 82 83 INFORMATION COPPER PVC INSULATED PVC SHEATHED
LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
Traveling Cable for Crane. www.tmc-cable.com. www.tmc-cable.com
Head Office / Ipjang Factory 443, Yeongok-gil, Ipjang-myeon, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Korea Tel. +82-41-589-6500 Fax. +82-41-589-6400 Bukmyeon Factory 5, Myungduk 1-gil, Buk-myeon, Dongnam-gu,
Offshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing
Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -
e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies
www.echtzeit.com e-mobility Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies Special cables for electric vehicles Wittener Straße 271 D-42279 Wuppertal Phone +49(0)202.2681.228 Fax +49(0)202.2681.360
Flygt flexible cables
Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR
FIBER-OPTIC CABLES LWL-KABEL
FIBER-OPTIC CABLES LWL-KABEL FIBER-OPTIC LOOSE TUBE OUTDOOR CABLE LWL-BÜNDELADER AUSSENKABEL TECHNISCHE DATEN - Technical Data A-DQ(ZN)B2Y 1200 N A-DQ(ZN)B2Y 2500 N ECO-KABEL - ECO cable STANDARDKABEL
High Voltage Systems. Today. The history of cables
High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,
Important Information: Complete Terms and Conditions are printed on sales invoices
Important Information: Complete Terms and Conditions are printed on sales invoices Notice: L&H Group is continually working to improve and add new products to the Cable Express product range. For this
FIBER OPTIC Cables. Cable for Indoor and Outdoor & Hybrid & Marine fiber optic cables
FIBER OPTIC Cables Cable for Indoor and Outdoor & Hybrid & Marine fiber optic cables TMC Co., Ltd has been pursuing innovation in technology and products for Ship and Information & Telecommunication industry.
Commercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
MICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
RELIABLE AND EFFICIENT MINING MINING CABLES
RELIABLE AND EFFICIENT MINING MINING CABLES 2 TABLE OF CONTENTS MINING CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENTIAL 5 VDE STANDARDS AND (HD) HARMONIZED STANDARDS OPEN PIT MINES R- (N)TSCGE WÖU 3.6/6
ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
The Quality Connection. Cables for Data Transmission in Industrial Automation
The Quality Connection Cables for Data Transmission in Industrial Automation Product range Instrumentation- and control cables Thermocouple extension and compensating cables Power cables (low and medium
450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
Flexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
Chemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
Copper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
Tri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
MV CABLE TYPE C 33-226
MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation
Flexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
Coaxial cables? Video cables Loudspeaker cables
Photo: ELUKABEL Coaxial cables? Video cables Loudspeaker cables Coaxial cables? Video cables Loudspeaker cables Coaxial cables are used in all areas of the high frequency transmission technology, for example
BETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
The Handbook 2013 EDITION
The Handbook 2013 EDITION Trust Als you safe Alsecure is the cable you can stake your reputation on when safety and security are critical to maintain circuit integrity for mains power, lighting, alarms,
Building Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
Fire retardant IEC 60332-1
300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting
TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH
Rev. 1:2007 TECHNICAL SPECIFICATION FOR LOW-FREQUENCY CABLES AND WIRES WITH PVC INSULATION AND PVC SHEATH Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor
Automotive Wire and Cable Products
Automotive Wire and Cable Products Primary Wires: ISO: Classes B - H JASO: AEX, AESSX, AVX, AVSSX : TXL, GXL, STX Engine Harness Wire: AutoRad Transmission Wire: Silicon & Non-Silicon Blocked Sensor Cables:
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
MacArtney Underwater Cables - In stock
MacArtney Underwater Cables - In stock The MacArtney Group depends on the support of a number of major cable manufacturers to supply a range of cables that are designed, manufactured and tested to meet
Specification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 INTRODUCTION... 4 CHAPTER I SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K... 6 H05V2-U, H05V2-R, H05V2-K... 7 H07V-U, H07V-R, H07V-K... 8 H07V2-U,
UGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
Catalogue Câbles d Energie
Catalogue Câbles d Energie Conductores Tecnológicos S.A. www.contecsa.es Index Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Câbles d Energie
Cable flexibility Flexible. Chemical resistance Accidental
H07RN-F Industrial flexible cable, insulation and outer sheath in elastomer Description pplication H07RN-F flexible cable is intended for installations with moving equipment, electric appliances and for
Cables & Accessories for Wind Turbines 2013 / 2014. www.helukabel.com
Cables & Accessories for Wind Turbines 13 / www.helukabel.com Welcome to HELUKABEL The logistic centre Heingen HELUKABEL is a global manufacturer and supplier of cables, wires & accessories. Founded in
NSW OFFSHORE AND SPECIAL CABLES. Cables for the future, delivered today.
NSW OFFSHORE AND SPECIAL CABLES. Cables for the future, delivered today. NORDDEUTSCHE SEEKABELWERKE GMBH (NSW) The submarine competence center within the General Cable Group NSW was founded in 1899 by
C A B L E P R O T E C T I O N
Safe cable protection! Elematic Cabling Systems produces in own plants a wide range of products for the cable protection, such as wiring spirals, insulated tubing, heat shrinkable tubing, etc. These products
APPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. [email protected] Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. [email protected]
6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
The Quality Connection. Solutions@KERPEN IT Cabling Systems
The Quality Connection Solutions@KERPEN IT Cabling Systems Contents At a glance Introduction Page MegaLineNet and GigaLineNet Applications and market segments Page Copper Cables and Systems: MegaLineNet
Allweather and Rubber Cables
HELUKABEL Products are available from MARYLAND METRICS P.O. Box 21 Owings Mills, MD 211 USA web: http://mdmetric.com ph: ()353130 (00)3130 fx: ()3532 (00)729329 email: [email protected] RFQ form: http://mdmetric.com/rfq.htm
MarineTuff Offshore and Marine Cable Solutions
Offshore and Marine Cable Solutions Belden offers the industry s largest selection of industrial cables for offshore and marine certified applications Whether you are handling oil, natural gas or petrochemicals,
Global cable solutions for harsh environment upstream applications, offshore topside and land drilling
Global cable solutions for harsh environment upstream applications, offshore topside and land drilling Oil & gas challenges Your offshore and land drilling projects need to operate more safely and profitably.
CLEVELAND CABLE LOCATIONS
A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables
2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G
Seattle Cit y Light 1 of 4 2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G 1. Scope This standard covers the detailed requirements