1 1 Single-Core PVC 1X : Single-Core PVC/PVC 1Y : Flat Twin & Flat Three Core PVC /Y : Multicore XLPE/LSF/SWA/LSF BS Control Cable : Single-Core XLPE/PVC : Single-Core XLPE/PVC/AWA/PVC Power Cable.... 1:1 Multicore XLPE/PVC/SWA/PVC Power Cable : Single-Core LSF 1B : Single-Core XLPE/LSF 1B :0 Single-Core XLPE/LSF/AWA/LSF Power Cable : Multicore XLPE/LSF/SWA/LSF Power & Control Cable : Single-Core XLPE/LSF/AWA/LSF kv Power Cable : Three Core XLPE/LSF/SWA/LSF kv Power Cable :0 BS Fire Resistant Cable : Fire Resistant Armoured Power Cable : Single-Core XLPE/PVC/AWA/PVC Power Cable.... 1: Three Core XLPE/PVC/SWA/PVC Power Cable :0 /./ kv PE/PVC Airfield Lighting Cable : Flat Twin & Flat Three Core LSF /B : Solar Cables for PV Applications : Technical Information :
2 1 Single-Core PVC 1X 0/0 V Application PVC insulated only cable for fixed wiring purposes. Used in trunking or conduit, or may be surface mounted when used for earthing. 1 1 Specifications In accordance with BS00 and Cenelec Harmonised codes - H0V-U (solid conductor) H0V-R (stranded conductor) s: Solid Class 1 or Stranded Class copper conductors to BS EN 0 Insulation: PVC Insulation Type TI.1 to BS EN 0- Flame retardant to BS EN 0-1- Normal colours available: green/yellow, blue, black, brown and grey Other colours available if required Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 0/0 V 0 01
3 Anixter Number Cenelec Code Area -## = colour, -0 = black, -0 = blue, -0 = brown, -0 = grey, -0 = green/yellow. Other colours available upon request. All dimensions are nominal unless otherwise stated. For further technical information see page 1:. For conductor short-circuit ratings see page 0:. Class Insulation Thickness Single-Core PVC 1X 0/0 V Maximum O/D Approx Weight A-A01-00-## H0V-U A-A0-00-## H0V-R A-A01-00-## H0V-U A-A-00-## H0V-R A-A0-000-## H0V-R A-A0-000-## H0V-R A-A0-00-## H0V-R A-A0-00-## H0V-R A-A0-00-## H0V-R A-A0-00-## H0V-R A-A-000-## H0V-R A-A-000-## H0V-R A-A-00-## H0V-R A-A-0-## H0V-R A-A-00-## H0V-R A-A-0-## H0V-R A-A1-00-## H0V-R A-A1-000-## H0V-R A-A1-000-## H0V-R A-A1-000-## H0V-R A-A1-00-## H0V-R kg/km Min Bending Radius (fixed bend)
4 1 Single-Core PVC/PVC 1Y 00/00 V Application PVC insulated and sheathed cable for fixed wiring purposes. Not suitable for direct burial. 1 Specifications In accordance with BS00 s: Solid Class 1 or stranded Class copper conductors to BS EN 0 Insulation: PVC insulation Type TI.1 to BS EN 0- Sheath: PVC sheath Type to BS Flame retardant to BS EN 0-1- Normal colours available. (See 1X page 1:) Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V
5 Anixter Number Area Class Single-Core PVC/PVC 1Y 00/00 V -##-## = colour, -0 = black, -0 = blue, -0 = brown, -0 = grey, -0 = green/yellow. e.g. A-C = black insulation, black sheath. A-C = brown insulation, black sheath. Other colours available upon request. For further technical information see page 1:. For conductor short-circuit ratings see page 0:. Insulation Thickness Minimum O/D Maximum O/D Approx Weight A-C01-00-##-## A-C01-00-##-## A-C01-00-##-## A-C0-000-##-## A-C0-000-##-## A-C0-00-##-## A-C0-00-##-## A-C0-00-##-## A-C0-00-##-## kg/km Minimum Bending Radius (fixed bend)
6 1 Flat Twin and Flat Three Core PVC Y and Y Insulated and sheathed with uninsulated circuit protective conductor as option Application PVC insulated and sheathed cable for installation clipped to flat surfaces, or embedded in plaster, etc. For domestic and industrial wiring. 1 1 Specifications In accordance with BS00 s: Solid Class 1 (up to. ) and stranded Class (above. ) copper conductors to BS EN 0 Insulation: PVC insulation Type TI.1 to BS EN 0- Core Identification: core - brown, blue core - brown, black, grey PVC sheath Type to BS Position of Protective : Twin - centrally placed between brown and blue cores Three core - centrally placed between black and grey cores Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V 0 01
7 Anixter Number Y - Flat Twin Area Flat Twin and Flat Three Core PVC Y and Y Insulated and sheathed with uninsulated circuit protective conductor as option Class Insulation Thickness Minimum O/D Maximum O/D Approx Weight Y x.. x. Y x.0. x. 0 Y x.. x. 0 Y x.. x. 0 0 Y x..0 x Y x 1.0. x.0 0 Y x..0 x. 0 Y - Flat Three Core Y x.. x. 0 Y x.. x. 0 0 Y x.. x Y x 1.. x. 0 0 Y x.0.0 x Y x.0. x. 0 0 Y x.0.0 x Anixter Number Area Class Insulation Thickness Minimum O/D Maximum O/D Nom earth Area kg/km Approx Weight kg/km Y - Flat Twin + Earth Y x.. x. 1.0 Y x.. x. 1.0 Y x.. x Y x.. x Y x 1..0 x Y x.. x Y x.0.0 x. 0 0 Y - Flat Three Core + Earth Y x.0. x Y x.. x Y x 1.. x Y x.. x Y x..0 x Y x 1.0. x. 0 0 Y x..0 x. 0 0 For further technical information see page 1:. For conductor short-circuit ratings see page 0:. Minimum Bending Radius (fixed bend) Min Bending Radius (fixed bend)
8 1 Multicore XLPE/LSF/SWA/LSF Control Cable 00/00 V Application Sheathed, multicore control cable. Especially for use in areas where fire would create dense smoke and toxic fumes causing a major threat to life and equipment. 1 1 Specifications In accordance with BS s: Stranded Class copper conductors to BS EN 0 Insulation: XLPE insulation Type GP to BS Core Identification: Number printed in black ink on white XLPE insulated cores Inner Sheath: LSF inner sheath Type LTS1 to BS Mild galvanised steel wires to BS EN -1 Outer Sheath: Black LSF outer sheath Type LTS1 to BS Flame retardant to BS EN 0-- & IEC0-- Cat. C as a minimum Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V 0 01
9 Anixter Number Number of Cores Area Multicore XLPE/LSF/SWA/LSF Control Cable 00/00 V Insulation Thickness For further technical information see page 1:. For conductor short-circuit ratings refer to page 0:. For armour short-circuit ratings refer to page 0:. Diam under Armour Armour Wire Size O/D Approx Weight A-AU-00N A-AV-00N A-AX-00N BS-C-00N A-O-C A-O-C A-O-C A-O-C A-O-C A-O-C A-AU-00N A-AV-00N A-AX-00N BS-C-00N A-P-C A-P-C A-P-C A-P-C A-P-C A-P-C kg/km Min Bending Radius (fixed bend)
10 1 Single-Core XLPE/PVC 00/00 V Application XLPE insulated and PVC sheathed cable for fixed installation. Not suitable for direct burial. 1 Specifications In accordance with BS s: Stranded Class copper conductors to BS EN 0 Insulation: XLPE insulation Type GP to BS Sheath: PVC sheath Type to BS Flame retardant to BS EN 0-1- Normal colours available. (See 1X page 1:) Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V
11 Anixter Number Area Insulation Thickness Single-Core XLPE/PVC 00/00 V -##-## = colour, -0 = black, -0 = blue, -0 = brown, -0 = grey, -0 = green/yellow. e.g. AEG = black insulation, black sheath. AEG = brown insulation, black sheath. Other colours available upon request. All dimensions are nominal unless otherwise stated. For further technical information see page 1:. For conductor short-circuit ratings refer to page 0:. O/D Approx Weight kg/km AEG-000-##-## AEG-000-##-## AEG-00-##-## AEG-0-##-## AEG-00-##-## AEG-0-##-## AEG-00-##-## AEG-000-##-## AEG-000-##-## AEG-000-##-## AEG-00-##-## AEG-000-##-## AEG-00-##-## Minimum Bending Radius (fixed bend)
12 1 Single-Core XLPE/PVC/AWA/PVC Power Cable 00/00 V and 00/00 V Application Armoured single-core cable for use in fixed installations, indoor, outdoor or direct burial. 1 Specifications In accordance with BS s: Stranded Class copper conductors to BS EN 0 Insulation: Brown XLPE insulation Type GP to BS Inner Sheath: PVC inner sheath Type to BS Aluminium wires to BS Outer Sheath: Black PVC outer sheath Type to BS Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 & 00/00 V
13 Anixter Number 00/00 V Cables Number of Cores Area Single-Core XLPE/PVC/AWA/PVC Power Cable 00/00 V and 00/00 V Insulation Thickness Diameter Under Armour Armour Wire Size For further technical information see page 1:. (See 1: for technical information on 00/00 V cables). For conductor and armour resistances refer to page 0:0. For gross cross-sectional area of armour refer to page 0:. For conductor short-circuit ratings refer to page 0:. For armour short-circuit ratings refer to page 0:. O/D Approx Weight BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C /00 V Cables ABX ABX ABX ABX ABX ABX ABX ABX ABX ABX ABX ABX ABX kg/km Min Bending Radius (fixed bend)
14 1 Multicore XLPE/PVC/SWA/PVC Power Cable 00/00 V and 00/00 V Application Armoured cables for use in fixed installations for use indoor, outdoor or for direct burial. 1 1 Specifications In accordance with BS s: Stranded Class copper conductors to BS EN 0 Insulation: XLPE insulation Type GP to BS Core Identification: core - brown, blue core - brown, black, grey core - brown, black, grey, blue core + above - number printed Inner Sheath: PVC inner sheath Type to BS Mild galvanised steel wires to BS EN -1 Outer Sheath: Black PVC outer sheath Type to BS Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V NB: 00/00V only available in core. 0 01
15 Multicore XLPE/PVC/SWA/PVC Power Cable 00/00 V and 00/00 V Anixter Number Number of Cores Area Insulation Thickness Diameter Under Armour Armour Wire Size O/D Approx Weight kg/km Min Bending Radius (fixed bend) 00/00 V BS-C-00 1.* BS-C-00.* BS-C-000 * BS-C-000 * BS-C-00 * BS-C BS-C-00 \\ BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C-00 1.* BS-C-00.* BS-C-000 * BS-C-000 * BS-C-00 * BS-C BS-C BS-C BS-C-000 0\\ BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C *Circular stranded conductors. \\ Shaped stranded conductors on sq & above ( core), 0sq & above ( & core). Circular or circular compacted stranded conductors. Continued overleaf
16 1 1 1 Multicore XLPE/PVC/SWA/PVC Power Cable 00/00 V and 00/00 V (continued) Anixter Number 00/00 V Number of Cores Area Insulation Thickness Diameter Under Armour Armour Wire Size O/D Approx Weight BS-C-00 1.* BS-C-00.* BS-C-000 * BS-C-000 * BS-C-00 * BS-C BS-C BS-C BS-C-000 0\\ BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C AAM-C00Q 1.* AAM-C01Q 1 1.* AAM-COQ 1.* AAM-C0Q 1.* AAM-C0Q 1.* AAP-C00Q.* AAP-C01Q 1.* AAP-C0Q.* AAP-C0Q.* AAP-C0Q.* kg/km Min Bending Radius (fixed bend) 0 01
17 Anixter Number 00/00 V Cables Number of Cores Area Multicore XLPE/PVC/SWA/PVC Power Cable 00/00 V and 00/00 V Insulation Thickness Diameter Under Armour Armour Wire Size *Circular stranded conductors. \\ Cables having conductors of nominal area 0sq and above have shaped stranded conductors. Circular or circular compacted stranded conductors. For further technical information see page 1:. (See 1: for technical information on 00/00 V cables). For conductor and armour resistances refer to page 0:1. For gross cross-sectional area of armour refer to page 0:. For conductor short-circuit ratings refer to page 0:. For armour short-circuit ratings refer to page 0:. O/D Approx Weight ABZ ABZ ABZ ABZ-000 0\\ ABZ ABZ ABZ ABZ ABZ ABZ ABZ ABZ kg/km Min Bending Radius (fixed bend)
18 1 Single-Core LSF 1B 0 C 00/00 and 0/0 V Application LSF insulated only cable for fixed wiring purposes. Used in trunking or conduit, or may be surface mounted when used for earthing. Especially for use in areas where fire would create dense smoke and toxic fumes causing a major threat to life and equipment. 1 1 Specifications In accordance with BS and Cenelec harmonised codes H0Z-U (Solid conductors) H0Z-R (Stranded conductors) s: Solid Class 1 or Stranded Class copper conductors to BS EN 0 Insulation: Low smoke zero halogen thermosetting insulation Type EI. to BS EN 0-, displaying following characteristics: Oxygen Index: 0% minimum HCL 00 C: 0.% maximum Flame retardant to BS EN 0-- (up to and incl. 1.0 ) and BS EN 0-1- (above 1.0 ) Normal colours available. (see 1X page 1:) Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: Up to and including /00 V 1. and above - 0/0 V 0 01
19 Anixter Number Cenelec Code Area Class Insulation Thickness -## = colour, -0 = black, -0 = blue, -0 = brown, -0 = grey, -0 = green/yellow. Other colours available upon request. All dimensions are nominal unless otherwise stated. For further technical information see page 1:. For conductor short-circuit ratings refer to page 0: for XLPE insulated cable. Single-Core LSF 1B 0 C 00/00 and 0/0 V Maximum O/D Approx Weight ABR-00-## H0Z-U ABT-00-## H0Z-R ABR-00-## H0Z-U ABT-00-## H0Z-R ABT-000-## H0Z-R1 0.. ABT-000-## H0Z-R1 0.. ABT-00-## H0Z-R ABT-00-## H0Z-R ABT-00-## H0Z-R ABT-00-## H0Z-R ABT-000-## H0Z-R ABT-000-## H0Z-R ABT-00-## H0Z-R ABT-0-## H0Z-R ABT-00-## H0Z-R ABT-0-## H0Z-R ABT-00-## H0Z-R ABT-000-## H0Z-R ABT-000-## H0Z-R ABT-000-## H0Z-R ABT-00-## H0Z-R kg/km Min Bending Radius (fixed bend)
20 1 Single-Core XLPE/LSF 1B 00/00 V Application XLPE insulated and LSF sheathed cable for fixed installation. Not suitable for direct burial. 1 Specifications Generally in accordance with BS s: Stranded Class copper conductors to BS EN 0 Insulation: Brown XLPE insulation Type GP to BS Sheath: Black LSF sheath Type LTS1 to BS Flame retardant to BS EN 0-- Other colours are available. (Details upon request) Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V
21 Anixter Number Area Other colours available upon request. Insulation Thickness O/D All dimensions are nominal unless otherwise stated. For further technical information see page 1:. For conductor short-circuit ratings refer to page 0: for XLPE insulated cable. Single-Core XLPE/LSF 1B 00/00 V Approx Weight kg/km 1B B B B B B B B B B B B B Minimum Bending Radius (fixed bend)
22 1 Single-Core XLPE/LSF/AWA/LSF Power Cable 00/00 V and 00/00 V Application LSF insulated, armoured and sheathed, single-core power cable for use in fixed installations. Especially for use in areas where fire would create dense smoke and toxic fumes causing a major threat to life and equipment. 1 1 Specifications In accordance with BS s: Stranded Class copper conductors to BS EN 0 Insulation: Brown XLPE insulation Type GP to BS Inner Sheath: LSF inner sheath Type LTS1 to BS Aluminium wires to BS Outer Sheath: Black LSF outer sheath Type LTS1 to BS Flame retardant to BS EN 0-- & IEC0-- Cat. C as a minimum Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 & 00/00 V 0 01
23 Anixter Number 00/00 V Cables Number of Cores Area Single-Core XLPE/LSF/AWA/LSF Power Cable 00/00 V and 00/00 V Insulation Thickness Diameter Under Armour Armour Wire Size CONDUCTORS MAY BE CIRCULAR OR CIRCULAR COMPACTED. For further technical information refer to page 1: (See 1: for technical information on 00/00 V cables). For conductor and armour resistances refer to page 0:0. For gross cross-sectional area of armour refer to page 0:. For conductor short-circuit ratings refer to page 0:. For armour short-circuit ratings refer to page 0:. O/D Approx Weight BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C BS-1C /00 V Cables A-AY A-AY A-AY A-AY A-AY A-AY A-AY A-AY A-AY A-AY A-AY A-AY A-AY kg/km Min Bending Radius (fixed bend)
24 1 Multicore XLPE/LSF/SWA/LSF Power and Control Cable 00/00 and 00/00 V Application LSF insulated, armoured and sheathed, multicore power cable. Especially for use in areas where fire would create dense smoke and toxic fumes causing a major threat to life and equipment. 1 1 Specifications In accordance with BS s: Stranded Class copper conductors Insulation: XLPE insulation Type GP to BS Core identification: core - brown, blue core - brown, black, grey core - brown, black, grey, blue core - brown, black, grey, blue, green/yellow Inner Sheath: LSF inner sheath Type LTS1 to BS Mild galvanised steel wires to BS EN -1 Outer Sheath: Black LSF outer sheath Type LTS1 to BS Flame retardant to BS EN 0-- & IEC0-- Cat. C as a minimum Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 & 00/00 V NB:00/00 V only available in core. 0 01
25 Anixter Number 00/00 V Cables Multicore XLPE/LSF/SWA/LSF Power and Control Cable 00/00 and 00/00 V Number of Cores Area Insulation Thickness Diameter Under Armour Armour Wire Size BS-C-00 1.* BS-C-00.* BS-C-000 * BS-C-000 * BS-C-00 * BS-C BS-C BS-C BS-C-000 0\\ BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C *Circular stranded conductors. \\ Shaped stranded conductors on sq & above ( core), 0sq & above ( & core). Circular or circular compacted stranded conductors. Continued overleaf... O/D Approx Weight BS-C-00 1.* BS-C-00.* BS-C-000 * BS-C-000 * BS-C-00 * BS-C BS-C-00 \\ BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C kg/km Min Bending Radius (fixed bend)
26 Multicore XLPE/LSF/SWA/LSF Power and Control Cable 00/00 and 00/00 V (continued) Anixter Number Number of Cores Area Insulation Thickness Diameter Under Armour Armour Wire Size O/D Approx Weight kg/km Min Bending Radius (fixed bend) BS-C-00 1.* BS-C-00.* BS-C-000 * BS-C-000 * BS-C-00 * BS-C BS-C BS-C BS-C-000 0\\ BS-C BS-C BS-C BS-C BS-C BS-C BS-C A-0-C00 1.* A-0-C * A-0-C0 1.* A-0-C0 1.* A-0-C0 1.* A-P-C00.* A-P-C01 1.* A-P-C0.* A-P-C0.* A-P-C0.* A-Q-C00 * A-Q-C01 1 * A-Q-C0 * A-Q-C0 * A-Q-C0 *
27 Anixter Number Multicore XLPE/LSF/SWA/LSF Power and Control Cable 00/00 and 00/00 V (continued) Number of Cores Area Insulation Thickness Diameter Under Armour Armour Wire Size 00/00 V Five Core Cables BS-C-00N 1.* BS-C-00N.* BS-C-000N * BS-C-000N * BS-C-00N * BS-C-00N BS-C BS-C BS-C BS-C BS-C BS-C /00 V Cables A-AZ A-AZ A-AZ-000 0\\ A-AZ A-AZ A-AZ A-AZ A-AZ A-AZ A-AZ A-AZ N.B. Part numbers for core cable ending in a letter N, e.g. BS-C-00N, indicate that the cable has number printed cores. All cables containing, 1,, and cores also have number printed core identification. * Circular stranded conductors. Circular or circular compacted stranded conductors. \\ Cables having conductors of nominal area 0sq and above have shaped stranded conductors (with the exception of core cables). For more technical information see page 1: (See 1: for technical information on 00/00 V cables). For conductor and armour resistances refer to page 0:1. For gross cross-sectional area of armour refer to page 0:. For conductor short-circuit ratings refer to page 0:. For armour short-circuit ratings refer to page 0:. O/D Approx Weight kg/km Min Bending Radius (fixed bend)
28 1 Single-Core XLPE/LSF/AWA/LSF Power Cable./ kv Application LSF armoured power cable for use in fixed installations. Especially for use in areas where fire would create dense smoke and toxic fumes causing a major threat to life and equipment. 1 1 Specifications In accordance with BS s: Stranded Class copper conductors to BS EN 0 Extruded semi-conducting layer Insulation: XLPE insulation Extruded semi-conducting layer Plain copper tape screen Inner Sheath: LSF inner sheath Type LTS1 to BS Aluminium wires to BS Outer Sheath: Red LSF outer sheath Type LTS1 to BS Flame retardant to BS EN 0-- & IEC0-- Cat. C as a minimum Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 0/100 V For further technical information refer to page 1:. 0 01
29 Anixter Number Number of Cores Area Single-Core XLPE/LSF/AWA/LSF Power Cable./ kv Insulation Thickness Diameter Under Armour Armour Wire Size O/D Approx Weight kg/km Minimum Bending Radius During Installation 0/100 V Cable AEN AEN AEN AEN AEN AEN AEN AEN AEN AEN AEN Adjacent to joints and Termination
30 1 Three Core XLPE/LSF/SWA/LSF Power Cable./ kv Application LSF armoured power cable for use in fixed installations. Especially for use in areas where fire would create dense smoke and toxic fumes causing a major threat to life and equipment. 1 1 Specifications In accordance with BS s: Stranded Class copper conductors to BS EN 0 Extruded semi-conducting layer Insulation: XLPE insulation Extruded semi-conducting layer Plain copper tape screen Inner Sheath: LSF inner sheath Type LTS1 to BS Mild galvanised steel wires to BS EN -1 Outer Sheath: Red LSF outer sheath Type LTS1 to BS Flame retardant to BS EN 0-- & IEC0-- Cat. C as a minimum Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 0/100 V For further technical information refer to page 1:
31 Anixter Number AEN- Number of Cores Area Three Core XLPE/LSF/SWA/LSF Power Cable./ kv Insulation Thickness Diameter Under Armour Armour Wire Size O/D Approx Weight kg/km Minimum Bending Radius During Installation Adjacent to joints and Termination
32 1 BS Fire Resistant Cable Incorporating circuit protective conductor (CPC) 00/00 V Application Unarmoured fire resistant cable for use in fixed wiring installations where it is necessary for the cable to retain circuit integrity in the event of a fire, e.g. emergency services, alarm systems, lighting. 1 1 Specifications In accordance with BS Part 1 BASEC Approved s: Solid Class 1 or stranded Class copper conductors to BS EN 0 Insulation: Silicone rubber insulation type EI to BS EN 0-1 Core Identification: core - brown, blue core - brown, black, grey core - brown, black, grey, blue, 1, core brown and black marker cores in each layer, remaining cores grey Woven glass tape to BS EN Tinned copper CPC (Class 1, or ) under and in contact with aluminium/mylar tape Low smoke zero halogen sheath Type LTS to BS (red or white) Fire resistant to IEC01 and categories CWZ of BS. Meets BS., ph0 BS EN 000 (Standard) Flame retardant to BS EN 0-1- Meets BS and IEC m cube smoke emission test Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V 0 01
33 Anixter Number Number of Cores Area Stranding #/ C.P.C. Area BS Fire Resistant Cable Incorporating circuit protective conductor (CPC) 00/00 V C.P.C. Stranding #/ Insulation Thickness BS-C-***-S 1. / / BS-C-***-S. /0.. 0/ Above details are based on Draka Firetuf cables. For further technical information see page 1:. *** WTE = white sheath, RED = red sheath. Nom O/D Approx Weight Solid s BS-C-*** 1.0 1/ / BS-C-*** 1. 1/ / BS-C-***. 1/1.. 1/ BS-C-*** 1.0 1/ / BS-C-*** 1. 1/ / BS-C-***. 1/1.. 1/ BS-C-*** 1.0 1/ / BS-C-*** 1. 1/ / BS-C-***. 1/1.. 1/ BS-C-*** 1.0 1/ / BS-1C-*** / / BS-C-*** 1.0 1/ / BS-C-*** 1. 1/ / BS-1C-*** / / BS-C-*** 1. 1/ / BS-C-***. 1/1.. 0/ BS-1C-*** 1. 1/1.. 0/ BS-C-***. 1/1.. 0/ Stranded s BS-C-***-S 1. /0. 1. / BS-C-***-S. /0.. / BS-C0-***-S.0 /0..0 / BS-C-***-S 1. /0. 1. / BS-C-***-S. /0.. / BS-C0-***-S.0 /0..0 / BS-C-***-S 1. /0. 1. / BS-C-***-S. /0.. / BS-C0-***-S.0 /0..0 / BS-C-***-S 1. / / BS-C-***-S. /0.. 0/ BS-1C-***-S 1 1. / / BS-1C-***-S 1. /0.. 0/ kg/km Min Bending Radius (fixed bend)
34 1 Fire Resistant Armoured Power Cable 00/00V Application Armoured fire resistant cable for use in fixed wiring installations where it is necessary for the cable to retain circuit integrity in the event of a fire, e.g. emergency services, alarm systems, lighting, etc., and in situations where power must be maintained to allow controlled closedown of equipment. 1 1 Specifications In accordance with BS BASEC Approved s: Stranded Class copper conductors to BS EN 0 Mica/glass tape (S) Insulation: XLPE insulation type GP to BS Core Identification: core - brown, blue core - brown, black, grey core - brown, black, grey, blue core + above - number printed Inner Sheath: LSF inner sheath Type LTS1 to BS Mild galvanised steel wires to BS EN -1 Outer Sheath: Black LSF outer sheath Type LTS1 to BS Fire resistant to IEC01 and categories CWZ of BS and BS Clause. Flame retardant to BS EN 0-- & IEC0-- Cat. C as a minimum Meets BS and IEC smoke emission test and ph0 BS EN 000 Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V 0 01
35 Anixter Number Two Core Number of Cores Area Insulation Thickness Fire Resistant Armoured Power Cable 00/00 V Diameter Under Armour Armour Wire Size O/D Approx Weight BS-C-00 1.* BS-C-00.* BS-C-000.0* BS-C-000.0* BS-C-00 * BS-C BS-C BS-C BS-C-000 0// BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C Three Core BS-C-00 1.* BS-C-00.* BS-C-000.0* BS-C-000.0* BS-C-00 * BS-C BS-C BS-C BS-C // BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C kg/km Min Bending Radius (fixed bend) Continued overleaf
36 1 1 1 Fire Resistant Armoured Power Cable 00/00 V (continued) Anixter Number Four Core Number of Cores Area Insulation Thickness Diameter Under Armour Armour Wire Size O/D Approx Weight BS-C-00 1.* BS-C-00.* BS-C-000.0* BS-C-000.0* BS-C-00 * BS-C BS-C BS-C BS-C-000 0// BS-C BS-C BS-C BS-C BS-C BS-C BS-C BS-C C+ 1.sq AEF * AEF * AEF * AEF * AEF * kg/km Min Bending Radius (fixed bend) 0 01
37 Anixter Number C+.sq Number of Cores Area Insulation Thickness Fire Resistant Armoured Power Cable 00/00 V (continued) *Circular stranded conductors. // Cables having conductors of nominal area 0sq and above will have shaped stranded conductors. Circular or circular compacted stranded conductors. For more technical information refer to page 1:0. For conductor and armour resistances refer to page 0:1 and 0:. For gross cross-sectional area of armour refer to page 0:. For conductor short-circuit ratings refer to page 0:. For armour short-circuit ratings refer to page 0:. Diameter Under Armour Armour Wire Size NB: and cables may be supplied with SHAPED conductors. Details on dimensions, weights etc., available on request. O/D Approx Weight AEF * AEF * AEF-00-0.* AEF-00-0.* AEF-00-0.* C+.0sq AEF * AEF * AEF * AEF * AEF * kg/km Min Bending Radius (fixed bend)
38 1 Single-Core XLPE/PVC/AWA/PVC Power Cable./.,./ and./ kv Application Power cable for use on fixed installations, indoor, outdoor or direct burial. 1 1 Specifications In accordance with BS s: Stranded Class copper conductors to BS EN 0 Extruded semi-conducting layer Insulation: XLPE insulation Extruded semi-conducting layer Plain copper tape screen Inner Sheath: PVC inner sheath Type to BS Aluminium wires to BS Outer Sheath: PVC outer sheath Type to BS Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00, 0/100, & 00/000 V For black sheath add suffix -0, for red sheath -0. For further technical information refer to page 1:. 0 01
39 Anixter Number Number of Cores Area Single-Core XLPE/PVC/AWA/PVC Power Cable./ kv Insulation Thickness Diameter Under Armour Armour Wire Size O/D Approx Weight kg/km Minimum Bending Radius During Installation 00/00 V Cables ACJ ACJ ACJ ACJ ACJ ACJ ACJ ACJ ACJ ACJ ACJ /100 V Cable ACT ACT ACT ACT ACT ACT ACT ACT ACT ACT ACT /000 V Cables ADE ADE ADE ADE ADE ADE ADE ADE ADE ADE ADE Adjacent to joints and Termination
40 1 Three Core XLPE/PVC/SWA/PVC Power Cable./.,./ and./ kv Application Multicore power cable for use on fixed installations. Indoor or outdoor use, or for direct burial. 1 1 Specifications In accordance with BS s: Stranded Class copper conductors to BS EN 0 Extruded semi-conducting layer Insulation: XLPE insulation Extruded semi-conducting layer Plain copper tape screen Inner Sheath: PVC inner sheath Type to BS Mild galvanised steel wires to BS EN -1 Outer Sheath: PVC outer sheath Type to BS Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00, 0/100, & 00/000 V For black sheath add suffix -0, for red sheath -0 to part number. For further technical information refer to page 1:
41 Anixter Number Number of Cores Area Three Core XLPE/PVC/SWA/PVC Power Cable./.,./ and./ kv Insulation Thickness Diameter Under Armour Armour Wire Size O/D Approx Weight kg/km Minimum Bending Radius During Installation 00/00 V Cables ACM ACM ACM ACM ACM ACM ACM ACM ACM ACM ACM ACM /100 V Cables ACW ACW ACW ACW ACW ACW ACW ACW ACW ACW ACW ACW /000 V Cables ADH ADH ADH ADH ADH ADH ADH ADH ADH ADH ADH Adjacent to joints and Termination
42 1 /./ kv PE/PVC Airfield Lighting Cable 1 1 Application For use in underground installations for airfield lighting. Specifications In accordance with D.O.E. (Department of the Environment) Spec M&E and BAA (British Airports Authority) Spec * ENG/0/CEE kv only s: Stranded Class copper conductors to BS EN 0 Insulation: Polythene insulation Type 0 to BS Sheath: PVC sheath Type TM.1 to BS Flame retardant to BS EN 0-1- Various colours available upon request Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 000 V/00 V/000 V * Embossing will state either M&E spec. or BAA spec. Standard stock is M&E spec. 0 01
43 Anixter Number Number of Cores Stranding #/ /./ kv PE/PVC Airfield Lighting Cable -## = sheath colour, -01 = white, -0 = black, -0 = red, -0 = green, -0 = yellow, -0 = blue, -0 = brown, -0 = orange, -0 = grey, - = violet, -1 = pink. Other colours available upon request. All dimensions are nominal unless otherwise stated. Insulation Thickness O/D Approx Weight kg/km Minimum Bending Radius (fixed bend) ABB-0-## 1 / ABB-00-## 1 / ABB-00-## 1 / Voltage Rating Volts
44 1 Flat Twin and Flat Three Core LSF B and B Insulated and sheathed with uninsulated circuit protective conductor as option Application LSF insulated and sheathed cable for installation clipped to flat surfaces, or embedded in plaster, etc. For domestic and industrial wiring. 1 1 Specifications In accordance with BS s: Solid Class 1 (up to. ) and stranded Class (above. ) copper conductors to BS EN 0 Insulation: XLPE insulation Type GP to BS Core Identification: core - brown, blue core - brown, black, grey Position of protective conductor: Twin - centrally placed between brown and blue cores Three core - centrally placed between black and grey cores Outer Sheath: LSF Sheath Type LTS to BS Flame retardant to BS EN 0-1- Temperature Rating: 0 C maximum conductor operating temperature Voltage Rating: 00/00 V 0 01
45 Anixter Number B - Flat Twin Area Flat Twin and Flat Three Core LSF B and B Insulated and sheathed with uninsulated circuit protective conductor as option Class For further technical information see page 1:0. For conductor short-circuit ratings see page 0:. Insulation Thickness Minimum O/D Maximum O/D Approx Weight B x.. x. B x.0. x. 0 B x.. x. 0 B x.. x. 0 0 B x..0 x B x 1.0. x.0 0 B x..0 x. 0 - Flat Three Core B x.. x. 0 B x.. x. 0 0 B x.. x B x 1.. x. 0 0 B x.0.0 x B x.0. x. 0 0 B x.0.0 x Anixter Number Area Class Insulation Thickness Minimum O/D Maximum O/D Nom Earth Area kg/km Approx Weight Min Bending Radius (fixed bend) kg/km B - Flat Twin + Earth B x..0 x B x.1. x. 1.0 B x..0 x B x.. x B x 1.0. x B x.. x. 0 0 B x.0.1 x B - Flat Three Core + Earth B x.0.1 x B x.. x B x x B x.0. x B x.. x B x.. x. 0 0 B x..1 x. 0 0 Min Bending Radius (fixed bend)
46 1 Solar Cable Application Used on both off-grid applications or grid connected PV-Systems. Construction Insulation Sheath Colour Anixter Number Tinned copper fine strands. Polyolefin Copolymer electron-beam cross-linked. Polyolefin Copolymer electron-beam cross-linked. Black. Technical Specification Voltage 00/00 V a.c., 00/00 V d.c. Test Voltage 000 V 0Hz, min. Temperature Rating -0 C to + C. Ambient Temperature > years (TÜV). -0 C to + 0 C. -0 F to + F. Bending Radius x outer diameter. Standards/Material Properties Fire Performance IEC Smoke Emissions IEC, EN 0-. Low Fire Load DIN 00. Approvals TÜV PfG /0.00 PV1-F. Application Standards NFPA 0 (National Electrical Code). Area Diameter Advantages High temperature resistance, the materials do not melt or flow Electron-beam cross-linked compounds UV and ozone resistant Hydrolysis resistant Good cold flexibility Very long life cycle Compatible to all popular connectors Tested and Certified Studer cable has both TÜV approval for the European market and UL approval according to the latest NEC specifications (National Electrical Code/UL Outline 0). Features and Benefits The double insulated, electron-beam cross-linked cables meets the highest requirements for solar cables in the most important photovoltaic markets of Europe and the USA and can be used unrestrictedly as a modular or connecting cable. The cables meet the same high expectations that are demanded from the solar modules - which are longevity and high weather resistance. Outer Diameter PV-SOLAR-1C-.MM..1. PV-SOLAR-1C-MM.. 0 PV-SOLAR-1C-MM.. PV-SOLAR-1C-MM..0 Approx Cable Weight kg/km 01
47 01
48 Technical Information Single-Core PVC Single-Core PVC/PVC (00/00 V) Single-Core PVC/PVC (1Y Types - 00/00 V) Single-Core PVC/PVC (1Y Types - 0/0 V) CURRENT - CARRYING CAPACITY (Amperes): Cross Sectional Area Reference Method A (enclosed in conduit in thermally insulating wall etc) Cables, Single Phase a.c. or d.c. or Cables Three Phase a.c. Reference Method B (enclosed in conduit on a wall or in trunking etc) Cables, Single Phase a.c. or d.c. or Cables Three Phase a.c. Reference Method C ( clipped direct ) Cables, Single Phase a.c. or d.c. Flat and Touching 1 A A A A A A or Cables Three Phase a.c. Flat and Touching or Trefoil 01
49 Technical Information If cables are to be used in ambient air temperatures other than 0 C the following rating factors should be applied: Ambient air temp C Rating factor Reference Method F (in free air or on perforated cable tray horizontal or vertical) Cables, Single Phase a.c. or d.c. flat and Touching or Cables Three Phase a.c. Flat and Touching Reference Method F (in free air or on perforated cable tray horizontal, vertical or trefoil) Horizontal Flat Spaced Vertical Flat Spaced Trefoil Cables, Single Phase a.c. or d.c. or Cables Three Phase a.c. Cables, Single Phase a.c. or d.c. or Cables Three Phase a.c. Three Phase a.c. 1 A A A A A Cables Trefoil Three Phase a.c
50 1 1 1 Technical Information Single-Core PVC Single-Core PVC/PVC (00/00 V) Single-Core PVC/PVC (1Y Types - 00/00 V) Single-Core PVC/PVC (1Y Types - 0/0 V) VOLTAGE DROP (per Ampere per metre): Cross Sectional Area cables d.c. Reference Methods A & B (enclosed in conduit etc in or on a wall) Cables - Single Phase a.c. Reference Methods C & F (clipped direct or on trays, touching) 1 Reference Method C & F (spaced*) mv mv mv mv r x z r x z r x z
51 Technical Information 1 Reference Methods A & B (enclosed in conduit etc in or on wall) Reference Methods C & F (in trefoil) or Cables - Three Phase a.c. Reference Methods C & F (flat touching) For further guidance refer to the BS1 (IEE Wiring Regulations - latest edition). * spaced by one cable diameter. Reference Methods C & F (flat spaced*) mv mv mv mv r x z r x z r x z r x z
52 1 1 1 Technical Information Flat Twin, Flat Twin & Earth Flat Three core, Flat Three core & Earth Multicore PVC-insulated flat cables, non-armoured, with or without protective conductor (copper conductors) BS00 - Flat Twin, Flat Three core Ambient temperature: 0 C. operating temperature: 0 C CURRENT - CARRYING CAPACITY (Amperes) Cross Sectional Area Reference Method 0# (above a plasterboard ceiling covered by thermal insulation NOT EXCEEDING 0 in thickness) Reference Method 1# (above a plasterboard ceiling covered by thermal insulation EXCEEDING 0 in thickness) Reference Reference Method # (in a stud wall with thermal insulation with cable TOUCHING the inner wall surface) Method # (in a stud wall with thermal insulation with cable NOT TOUCHING the inner wall surface) Reference Method C* (clipped direct) 1 (A) (A) (A) (A) (A) (A) Reference Method A* (enclosed n conduit in an insulated wall) A* For full installation method refer to Table A Installation Method but for flat twin and earth cable C* For full installation method refer to Table A Installation Method 0 but for flat twin and earth cable 0# For full installation method refer to Table A Installation Method 0 1# For full installation method refer to Table A Installation Method 1 # For full installation method refer to Table A Installation Method # For full installation method refer to Table A Installation Method Wherever practicable, a cable is to be fixed in a position such that it will not be covered with thermal insulation. Regulation., BS 0-: Appendix C: Avoidance of overheating of electric cables. Building Regulations Approved document B and Thermal insulation: avoiding risks, BR, BRE, 001 refer. 0 01
53 Technical Information 1 VOLTAGE DROP (per Ampere per metre): Cross Sectional Area Two Core Cable d.c. Two Core Cable Single Phase a.c. 1 mv mv mv If cables are to be used in ambient air temperatures other than 0 C the following rating factors should be applied: Ambient air temp C Rating factor For further guidance refer to BS1 (IEE Wiring Regulations - latest edition). * With or without protective conductor. Three or Four Core Cable Three Phase a.c
54 1 Technical Information Single-Core LSF Single-Core XLPE/PVC, XLPE/LSF (1) Types 00/00 V 1 1 CURRENT - CARRYING CAPACITY (Amperes): Cross Sectional Area Reference Method A (enclosed in conduit in thermally insulating wall etc) Cables, Single Phase a.c. or d.c. or Cables Three Phase a.c. Reference Method B (enclosed in conduit on a wall or in trunking etc) Cables, Single Phase a.c. or d.c. or Cables Three Phase a.c. Reference Method C ( clipped direct ) Cables, Single Phase a.c. or d.c. Flat and Touching 1 A A A A A A or Cables Three Phase a.c. Flat and Touching or Trefoil 0 01
55 For ambient air temperatures other than 0 C, the following rating factors should be applied: Technical Information Ambient air temp C Rating factor Reference Method F Reference Method G (Free air) (on a perforated cable tray horizontal or vertical) Horizontal Flat Spaced Vertical Flat Spaced Trefoil Cables, Single Phase a.c. or d.c. Flat and Touching or Cables Three Phase a.c. Flat and Touching Cables, Single Phase a.c. or d.c. or Cables Three Phase a.c. Cables, Single Phase a.c. or d.c. or Cables Three Phase a.c. 1 A A A A A Cables Trefoil Three Phase a.c. Ratings shown in Column 1, also apply to cables in trefoil formation on a perforated cable tray, Reference Method F
56 Technical Information Single-Core LSF Single-Core XLPE/PVC, XLPE/LSF (1) Types 00/00 V Continued... VOLTAGE DROP (per Ampere per metre): Cross Sectional Area cables d.c. *Spaced by one cable diameter. Reference Methods A & B (enclosed in conduit etc in or on a wall) Cables - Single Phase a.c. Reference Methods C, F & G (clipped direct or on trays, touching) 1 Reference Method C, F & G (spaced*) mv mv mv mv r x z r x z r x z
57 Technical Information 1 Reference Methods A & B (enclosed in conduit etc in or on wall) Reference Methods C, F & G (in trefoil) or Cables - Three Phase a.c. Reference Methods C, F & G (flat touching) For further guidance refer to the BS1 (IEE Wiring Regulations - latest edition). Reference Methods C, F & G (flat spaced*) mv mv mv mv r x z r x z r x z r x z
The Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com
More informationAFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:
PRODUCT DATASHEET & APPLICATIONS GUIDE BASEC APPROVED AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 KEY BENEFITS: BASEC approved for the full size range of BS8436 (1.0mm 2 to 2.5mm 2
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
More informationFIRE RESISTANT CABLES FP200 GOLD
FIRE RESISTANT CABLES FP200 GOLD FIRE RESISTANT CABLES FP200 GOLD BS7629-1:2008 Certificate No 077f Certificate No 077k FP200 GOLD The original highly durable and dressable, easy to terminate and install
More informationScottishPower Distribution Cables & Equipment. Metal Theft
ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated
More informationFire Resistant Cables
109/4 Fire Resistant Cables SR 114H Standard - SR 114E Enhanced BS 5839-1 BS 7629-1 BS 6387 BS 8434-1/2 BS 6425 BS 7622 EN 50200 World-wide recognized high quality cables Firecel SR114 are used in: Data
More informationCURRENT RATINGS MORE THAN A CABLE
CURRENT RTINGS Updated for the 17th Edition of the IEE Wiring Regulations MORE THN CBLE C O M P N Y EI CBLES, DURHM ROD, BIRTLEY, CO DURHM. DH3 2R Tel: +44 (0)191 410 3111 Fax: +44 (0)191 410 8312 E-mail:
More informationwww.ptranscable.com We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K
P-trans, meaning power transistor, is a well known cable manufacturer based in Aan - Jordan. The production plant produces all sorts of high quality low tension cables and is a leader in the industry supplying
More informationISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008
ISO 9001 ISO 14001 CABLES AND WIRES CATALOGUE 2008 INTRODUCTION... 4 CHAPTER I SINGLE CORE NON-SHEATHED CABLES H05V-U, H05V-R, H05V-K... 6 H05V2-U, H05V2-R, H05V2-K... 7 H07V-U, H07V-R, H07V-K... 8 H07V2-U,
More informationCONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
More informationFIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
More informationCABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
More informationFlexible Cables and Cords
PVC Types Tri-Rated Single-Core....................... : H0V-K (1X) & H0V-K (01X) Single-Core... : DEF 1-1 Equipment Wires.................. : PVC Insulated and Sheathed Flexible Multicore (1*Y).........................
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More informationENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application
ENERGY TECWATER S1BN8-F 0,6/1 kv Cable for Water Application Technical Data Electrical parameters Thermal parameters Trademark Type designation Specification Approval Application Rated voltage Maximum
More informationCLEVELAND CABLE LOCATIONS
A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2011 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables
More informationMV CABLE TYPE C 33-226
MV CABLE TYPE C 33-226 Standards : CENELEC HD 620 C 33-226 Rated voltage Rated voltage : 12/20 (24) kv Design 1 Stranded aluminium, class 2 conductor 2 Extruded conducting screen on conductor 3 XLPE insulation
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More information4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters
8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article
More informationCables, Cable Laying & Accessories Manual
Distribution Business Cables, Cable Laying & Accessories Manual Database ref: File Ref: Title Page & Revision Log For Cables & Access v4 - Nov 2003.doc Manual Name: Cables & Accessories Manual Version
More informationFLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
More informationUGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
More information3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
More informationVIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
More informationBETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
More informationMEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
More informationGlobal cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More informationRADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
More informationLOW VOLTAGE POWER CABLES
LOW VOLTAGE POWER CABLES CONTENTS 1 4 GENERAL INTRODUCTION TECHNICAL BARE SOFT DRAWN STRANDED CONDUCTORS 38 39 44 48 52 53 56 59 60 63 68 72 75 76 79 82 83 INFORMATION COPPER PVC INSULATED PVC SHEATHED
More informationMEDIUM VOLTAGE CABLES Up to and including 36 KV
MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types
More informationFlexible cables for submersible products
Flexible cables for submersible products Standards SUBCAB cables complies with the following general standards: IEC 6045 (general) IEC 608 class 5 (conductor) IEC 608-- CLAUSE 9 (oil resistant) IEC 608--
More informationFlygt flexible cables
Flygt flexible cables Contents Standards General SUBCAB 4 Screened SUBCAB 6 Rubber cable type: NSSHÖU-J 7 Screened rubber cable type: NSSHÖU../E + ST 8 FGB screened rubber cable 9 PUR control cable 0 HCR
More informationBRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
More informationCurrent Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69
Ratings TBLE BEC 107. (Continued) ratings for 60/11000 volts grade PILC/SW/PVC cable to BS64/69 CBLES LID IN IR: The ratings given in the foregoing tables are based on an ambient of C. It is recommended
More informationChemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
More informationImportant Information: Complete Terms and Conditions are printed on sales invoices
Important Information: Complete Terms and Conditions are printed on sales invoices Notice: L&H Group is continually working to improve and add new products to the Cable Express product range. For this
More informationTri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
More informationEDS 02-0027 11KV TRIPLEX CABLE
THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE Document Number: EDS 02-0027 ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE Network(s): EPN, LPN, SPN Summary:
More informationAirdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017 Conductor: Hard Drawn Copper Conductor Class 2 Insulation: LV-XLPE Phase Color Code(SNE): Red, Black & Bare Copper Phase
More informationTechnical cable guide
Technical cable guide November 2014 One stop-shop for all your cable needs Welcome to the latest edition of the Technical Cable Guide. Following the recent acquisition of Draka, the Prysmian Group is now
More informationENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics
ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany
More informationCorporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
More informationwith coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
More informationOffshore Transformer Platform. Technical Standard. Energinet.dk. HV, MV, LV and Signal Cables and Cable Routing
Offshore Transformer Platform Technical Standard Energinet.dk HV, MV, LV and Signal Cables and Cable Routing ETS - 03 Rev. 1 Acadre doc. 44858-09 Revision survey Chpt. Description Revision Date Resp. -
More informationFlexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
More informationThe Handbook 2013 EDITION
The Handbook 2013 EDITION Trust Als you safe Alsecure is the cable you can stake your reputation on when safety and security are critical to maintain circuit integrity for mains power, lighting, alarms,
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More information6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
More informationHigh Voltage Systems. Today. The history of cables
High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More informationInternational Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More informationFire Performance Standard
Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables. Flame Retardant
More informationFOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.
OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively
More informationBuilding Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
More informationIndustrial Cable Solutions for Variable Frequency Drives
Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationSCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA
SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/ 1 X C-UA- LTXLPE/2006) MAHARASHTRA STATE ELECTRICITY
More informatione-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies
www.echtzeit.com e-mobility Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies Special cables for electric vehicles Wittener Straße 271 D-42279 Wuppertal Phone +49(0)202.2681.228 Fax +49(0)202.2681.360
More informationMICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
More informationRemoval of EP 20 10 00 02 SP High Voltage Cable
TN 018: 2014 Technical Note For queries regarding this document standards@asa.transport.nsw.gov.au www.asa.transport.nsw.gov.au TN 018: 2014 Issued date 12 March 2014 Effective dates 12 March 2014 Subject:
More informationNetwork Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
More informationSCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More informationScreened cable and data cable segregation
December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;
More informationHINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001
NEW POL DEPOT AT HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & S GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI-400 001 TECHNICAL SPECIFICATION OF XLPE, FRLS LT CABLES
More information450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
More informationFibre optic cables MDIC LSZH
MDIC LSZH MDIC LSZH - Indoor Access Cable. Micro Drop Installation Cable, special Access cable with low bend radius, no waterpeak G.657.A fibres. Ruggedized construction with excellent performance, easy
More informationOutside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
More informationB05: Cable protection and sheathing
SHEATHING MATERIALS MDPE, BLACK This is the standard sheathing material for cables for outdoor use. The material is UV stabilised with using 2.5 ± 0.5 % carbon black. It has excellent weathering resistance.
More informationVDE-approved PVC-Control Cables
Works photo: HELUKAEL VDE-approved PVC-Control Cables VDE-approved PVC-Control Cables This certification/licency is issued according to the rules of the HAR Agreement, wherein the certification/ licency
More informationSizing conductors and selecting protection devices
Sizing conductors and selecting protection devices 04 PowEr guide 2009 / BOOk 04 INTRO Careful selection of the sizes of the conductors in wiring systems and the characteristics of protection devices will
More informationCable flexibility Flexible. Chemical resistance Accidental
H07RN-F Industrial flexible cable, insulation and outer sheath in elastomer Description pplication H07RN-F flexible cable is intended for installations with moving equipment, electric appliances and for
More informationInstrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
More informationXLPE Land Cable Systems User s Guide. Rev 5
XLPE Land Cable Systems User s Guide Rev 5 CONTENT XLPE Land Cable Systems Introduction... 3 Design, installation and testing... 4 XLPE cables... 4 Cable accessories... 4 Installation of XLPE cable systems...
More informationAPPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. rohinib@ducab.com Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. Nawaf@ducab.com
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationTHE PATHWAY TO POWER HIGH-VOLTAGE CABLES
THE PATHWAY TO POWER HIGH-VOLTAGE CABLES TABLE OF CONTENTS HIGH-VOLTAGE CABLES 3 Advantages of XLPE-insulated cable systems 3 PROPOSAL 4 Cable systems 4 Providing System Solutions 4 Continuous temperature
More informationSpecializing in the cable business for over 38 years, PT. SUPREME CABLE
Specializing in the cable business for over 38 years, PT. SUPREME CABLE MANUFACTURING & COMMERCE Tbk. (PT. SUCACO Tbk) has grown steadly to become a largest and leading cable manufacturer, with international
More informationTemperature Permissible ambient temperature. Weather Resistance to severe weather conditions. Impacts Cable mechanical resistance to impacts
Airfield Cables Issue 10/2003 Piktogramme Temperature Permissible ambient temperature Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance
More information108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
More informationThe Quality Connection. BETAflam Fire safety cables
The Quality Connection BETAflam Fire safety cables 2 We connect tomorrow's world already today. BETAflam Safety cables Halogen-free and environmentally friendly cables and single cores for applications
More informationWHITE PAPER Fire & safety performance standards
WHITE PAPER Fire & safety performance standards Terminologies describing Fire Performance Terminologies describing Fire Performance often present a challenge to understand as how they apply to a cable
More information5.2. Overview. The better method to install solderless compression connectors on power cable
5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree
More informationThe National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables
The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing
More informationBritish Standards BSEN 3475-513:2005
s British Standard BS 91:1998 BS 215:1970 BS 638-4:1996 BS 1990-1:1984 BSEN 3475-100:2002 BSEN 3475-201:2002 BSEN 3475-301:2002 BSEN 3475-302:2002 BSEN 3475-303:2002 BSEN 3475-305:2002 BSEN 3475-306:2005
More informationGexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
More informationIEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
More informationFire retardant IEC 60332-1
300 / 500 V Description Approval Certificates VDE Reg N 7691 Application In dry and moist rooms for light mechanical stresses. Outdoors only when protected. Not in water. As supply and interconnecting
More informationCatalogue Câbles d Energie
Catalogue Câbles d Energie Conductores Tecnológicos S.A. www.contecsa.es Index Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Câbles d Energie
More informationCopper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
More informationLT/HT Power & Control Cables
LT/HT Power & Control s Catalogue 2014 HT Power s upto 66kV 1.1 kv Power s 1.1 kv Copper Control s ISO-9001/ 14001/18001 Certified Certification Building customer confidence by providing a wide range of
More informationGUIDE TO THE AM2 EXAM
AM2 GUIDE TO THE AM2 EXAM What is AM2? AM2 or the Achievement Measurement 2 is a practical performance skill test administered by the National Electrotechnical Training (NET). You must take the AM2 test
More informationRAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN
RAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN RAIL /// WIRE & CABLE EVERY CONNECTION COUNTS The Rail industry is changing rapidly, to match global demands for greener, more intelligent transportation.
More information