1 BOQ FOR ELECTRICAL WORK OF HLST IN GROUND FLOOR AT S.B.I. LHO BHOPAL. Note: Use of Flexible conduits & Elbows in Circuit wiring is not allowed except in exceptional site conditions with the approval of Bank's Engineer / Architect and All wiring laying in the MS/PVC conduit strickly follow IE( Indian Electricity) rules and IE(Indian Electricity) rules follow in all items of project. Proper ferrules, lux, thimble to be done in all cabling and wiring from both load/source end. S.No. DESCRIPTION QTY UNIT RATE AMOUNT 1 ELECTRICAL WIRING Providing & fixing POINT WIRING for Ceiling and wall lights, Ceiling fan, wall fan, exhaust fan, Plug points Bell points. The item includes Circuit wiring from DB to the switch board with 3x2.5 Sq.MM PVC insulated copper conductor single core multistrended wire for Phase, Neutral & Earth (P+N+E) in appropriate size 20/25mm dia of 16 SWG wall thickness, MS medium conduits ( stove enamelled regid steel conduit) ISI mark (IS :9537), point wiring to be with 3x1.5 Sq.MM PVC insulated copper conductor with all necessary accessories, such as saddles etc. on surface or embedded in wall, chasing the walls and making the surface neat afterwards. Item includes 6 AMP switch, socket, etc. PHILIPS ELITE, MK / NORTH WEST & ANCHOR ROMA, with all base plates, covering plate Metal box of same make etc. complete. (EACH Circuit to take NOT MORE than 7-8 points) Flexible conduits & Elbows are not allowed. Flexible conduit use it must be joined by gland and check nut at both ends. Only FRLS wire to be used a) but One point controlled by one switch.(i.e. inclusive of mains wiring). 55 Nos. b) but 2 points to be controlled by one switch.(i.e. inclusive of mains wiring). 10 Nos c) 3 but for one Exhaust fan point Nos. d) 6 AMP socket point on same board 15 Nos. Providing and fixing point wiring with same specs as above but for CIELING FAN e) points with 1x 5pin 6Amp socket outlet to be provided at the location of fan (i.e. inclusive of mains wiring).one Switch and one no stepped electronic regulator ( two 7 Nos. Module Providing ) as and fixing point wiring with same specs as above but for WALL FAN points f) with 1x 5pin 6Amp socket outlet to be provided at the location of fan (i.e. inclusive of mains wiring). 10 Nos. 6/16 AMP power point with 3x 2.5 sq.mm. wire and 20 mm dia. 16 swg stove g) enameled rigid steel conduits with 1x 5pin 6/16 Amp socket outlet. No extra cost for wiring and conduits is payable (i.e. inclusive of mains wiring). 20 Nos. providing and fixing 6 Amps Plug Points with same specs as above but along with h) separate switchboard with 1x 5pin 6Amp socket outlet (separate point wring)(i.e. inclusive of mains wiring). 15 Nos Call bell point with call bell with 3x1.5 sq.mm. wire and 20 mm dia. 16 swg stove i) enameled rigid steel conduits. No extra cost for wiring and conduits is payable (i.e. inclusive of mains wiring). 5 Nos. j) SPECIAL POINTS : ( For Computers ) Supply, fixing, testing and commissioning of following Modular type switch socket with cover plate, PVC modular box on Surface / sheet steel box in concealed manner I/c electrical connections and making good all the damages, painting, cleaning the site etc complete as required as per site requirement and as directed.ups point with 3x 2.5 sq.mm. wire and 20 mm dia. 16 swg stove enameled rigid steel conduits. (i.e. inclusive of mains wiring). 2 Nos. 6/10A Switch + 3 Nos. 6/10A, 3 pin Socket 30 Nos. 2 A.C. point Supply, Installation, commissioning & Testing of the surface / recess mounting A.C. point as per above point wiring with 3x 4 sq.mm. PVC wiring in M.S. Conduit pipe, etc. with the followings : 32 A D.P.,1 way switch with neon with plate and box.- 1 set 25 A & 10 A Twin socket with plate and box.- 1 Set. i/c electrical connections and making good all the damages, painting, cleaning the site etc complete as required as per site requirement and as directed.(i.e. inclusive of mains wiring). 16 Nos. 3 MUSIC SYSTEM WIRING a) SPEAKERS supplying,installation,testing and commissioning 4 to 6 W speakers, off white High impact ABS plastic grill with spring loaded mounting clamps, good for mounting in false ceiling etc complete in all respect. 8 Nos b) PVC CONDUITS Supplying,laying /fixing of the following size conduit with conduit accessories like bend/junction box /on surface /floor /recees manner and making good all the damages,painting,cleaning the site etc complete as required. 20mm Dia. 1.6mm wall thickness rigid PVC conduits 110 RM c) SPEAKER WIRING Supplying,providing wiring (supply,fixing,testing and comm etc.),for light /power with following PVC insulated copper conductor,single core multi strended wire (HRFR ) in existing conduit including connections and making good all the damages,painting cleaning the site etc. complete as required as per the requirement and as directed 2x1.5 sqmm 130 RM

2 4 TELEPHONE POINT i) Supplying and fixing of krone telephone tag block, suitable for the multi core telephone cable and shall accommodate tin-plated phosphor bronze connectors, the connectors shall splice unskinned cables up to 0.61 mm dia and shall be terminate both incoming and out going lines, the tag blocks shall be mounted inside, water proof box and locking arrangement and shall be fully accessibie.the item is inclusive of providing and fixing of boxes in surface / recessed system etc complete as a. 20 Pair Tag Box 2 Nos ii) Supplying, Installation, testing and commissioning of the telephone point with the followings - a. Two pair, 0.50 mm dia. telephone cable tinned copper conductor, P.V.C. insulated and sheathed, fire retarding, anti termite, colour coded twisted pairs and rip cord. 350 Mtrs. b. Double outlet with shutter modular type Telephone Outlets ( RJ 11 ) with suitable size M.S./ PVC modular boxes complete as req. 30 Nos. iii) Supplying, Laying / Fixing of the following size conduit with conduit accessories like bend / junction box / fan box etc on surface / recessed manner and making and making good all the damages, painting, cleaning the site etc complete as required as per site requirement and as directed. a. 20 mm dia.1.6 mm wall thickness rigid PVC conduits. 120 Mtrs b. 25 mm dia.1.6 mm wall thickness rigid PVC conduits. 90 Mtrs. 5 Supply and fixing of 'S' type fan hook in the ceiling by cutting / chiesling, replastering, painting etc complete in all respect. 7 Nos. 6 Fitting and fixing of existing electrical equipments & fittings proper Installation, commissioning & Testing including required accessories, fastners and for fans hanging rods/pipes, ball sockets etccomplete as required as per site conditions. Light fittings in false ceiling/on wall/ceiling & all size of Ceiling Fans/wall fans/exhaust fan etc 10 Nos. 7 Dismentaling of all wirings, switch, sockets,dbs, Light fixtures & Fans etc.as per requirement at site. 1 Job 8 DISTRIBUTION BOARDS All MCB to be "C" series Supply, installation, commissioning & Testing of the surface/recess mounting following ways MCB DB's 230/415 Volts on surface/recessed, complete with tinned copper Busbar, Neutral Bar, Earth Bar, Din Bar detachable gland plate, interconnection and making good all the damages, painting, cleaning the site etc complete as required as per site requirement and as directed. A. LIGHT DISTRIBUTION BOARD : 1 Nos a. 1 no. TPN MCB DB 4 way ( ways ) b. 1 no TPN MCB 32 amp. 12 nos SP MCB 06 amp. c. B. POWER DISTRIBUTION BOARD : 1 Nos 1 no. TPN MCB DB 4 way ( ways ) a. b. 1 no TPN MCB 63 amp. c. 12 nos SP MCB 20/32 amp. C. U.P.S. POWER DIS.BOARD ( For UPS Out Goings ) : 1 Nos a. 1 no.spn MCB DB 12 way ( ways ) b. 1 no SPN MCB 32 amp. c. 10 nos SP MCB 10 amp. D. U.P.S. DISTRIBUTION BOARD ( for UPS IN PUT ) : 1 Nos. a. 63 A SPN MCB 1 no. b. 1 No Fabricated 18 swg m.s.box of suitable size OR factory made. E LOAD LINE DB ( Double door ) : 1 Nos. Supplying and fixing of following 4 Way three pole and neutral, sheet steel Vertical MCB distribution board, 415 volts on surface / recess,

3 complete with tinned copper busbar, neutral bar, earth bar, din bar, detachable gland plate with Cable termination box, interconnection including painting,earthing etc as required,with the followings - a 01 no. 125 amp., 10 KA, TP MCCB b 32 A TP MCB - 02 Nos. c 63 A TP MCB - 02 Nos. 9 LAN - ( LOCAL AREA NETWORKING ) FOR COMPUTERS : a Supply, Installation, Testing and Commissioning of 24 Port ( 100 base TX ) Cat-6 Patch / jack panel with connectors, outlets and necessary connectivity complete as 1 Nos. b Supply and Installation of following factory fabricated patch cords ( UTP-CAT 6 ) complete with connectors on both sides. i One Meter length. 30 Nos. ii Two Meter length. 30 Nos. c Supply and laying of Four Pair UTP CAT 6 LAN cables in existing PVC Conduit / Floor trunking with RJ-45 connector if required as per requirement. 490 Mtrs. d Supply and fixing of modular type Information Outlets with suitable size M.S./ PVC modular boxes complete with insulation displacement connectors etc suitable for CAT 6 UTP Cabling. i One Port. 30 Nos. e Supply, Installation, Testing and Commissioning of the following 10 / 100 Mbps Rack mounted Switch ( Auto managed ) suitable for auto-sense the network speed of the connected nodes to run at either 10 Mbps or 100 Mbps. The port also auto negotiate between full / half duplex and cable cross over. a). 24 RJ base T / 100 Base TX port. 1 Nos. f Supply, Installation, Testing and Commissioning of the following Rack on existing wall / table / plateform etc i/c fixing of equipment/ accessories etc as i 9 U Rack. 1 Nos. 10 CONDUITS Supplying, Laying / Fixing of the following size conduit with conduit, accessories like bend/junction box /fan box etc on surface/recessed manner and makingood all the damage painting,the site etc complete as per site requirement and as directed by Engg. In-Charge. a) 20 mm dia.pvc conduits. 180 RM b) 25 mm dia.pvc conduits. 160 RM 11 CABLING Supplying, unloading, storing, laying, testing and commissioning of following sizes of PVC /XLPE insulated (heavy duty)ai./ following sizes of PVC / XLPE insulated (Heavy duty) Al / Cu conductor armored cables suitable for working voltage up to armored cables suitable for working voltage upto and including 1100 volts,laid and tied on existing overhead cables trays or laid and tied over MS supports in Volts, laid and tied on existing overhead cable trays; or laid and tied over s in masonry trenches including providing MS including providing MS supports and clamps for fixing to supports ; or buried in ground complete as required as specifications required and as per specifications. a) 3.5 Core, 70 sq.mm Al. Cable.(main cable) 40 RM b) 4.0 Core, 25 sq.mm Al. Cable.(Power DB) 75 RM c) 4.0 Core, 10 sq. mm Al. Cable.(Light DB) 75 RM 12 CABLE END TERMINATION : ( 1100 V Gr.Cable ) Termination of the following sizes ( 4 / 3.5 core ) of XLPE insulated Aluminum conductor cable. Including providing terminal lugs single compression gland, crimping the joints, insulation tape effecting terminal connections to the equipment complete as required Up to 70 sq mm 10 Nos ELECTRICAL FAN AND FITTINGS 13 CEILING FANS Supply and fixing of the following ceiling fans. ( Brilliant white ) 1200 mm sweep 7 Nos. 14 WALL FANS Supply and fixing of the following wall fans. ( Brilliant white ) 400 mm sweep, 1300 rpm. 10 Nos.

4 15 EXHAUST FANS Supply and fixing of the 300 mm sweep exhaust fan with frame, Including making hole in the wall for fixing, and making good the civil damages etc as required 3 Nos. LED LIGHT FITTINGS 16 Supply, fixing,commissioning & testing of ceiling mounted Environment Friendly, Energy Efficient,decorative Square molded body Ceiling Mounted LED light Fixture with opel diffuser to give Glare free light with class-1 electrical safety, complete as 8 W-LED Light Fixture- Down Lighter 20 Nos. 17 Supply, fixing, commissioning & testing of ceiling/wall mounted Down Lighter Environment Friendly, Energy Efficient,decorative Round Ceiling Mounted LED light Fixture with with electronic driver for indoor applications with class I electrical safety, complete as 15 W- LED Light Fixture Down Lighter 4 Nos. 18 L E D TUBE LIGHT Supply, fixing, commissioning & testing of ceiling/wall mounted Environment Friendly, Energy Efficient,decorative Ultra Slim Linear light Fixture with extruded Aluminum heat Sink with class I electrical safety, complete as 20 W LED 4 0 Tube Light 6 Nos. 19 Supply of Energy efficient recess mounted 2'X2' ceiling mounted 36/38 watt LED light fixture with:- a) White powder coated Metallic CRCA housing. b) High-power, high efficiency LEDs (makes:cromptom/philips/syska/bajaj/havells make 25 Nos. 20 G.I.PLATE EARTH STATION : Preparation of the Plate Earth Station: (as per IS:3043) Excavation of rocky earth, soft murrum, hard murrum etc and back filling with black cotton soil for the earth station, the earth pit size is 1000 mm x 1000 mm x 2500 mm deep. S/F of G.I. plate of size 600 x 600 x 6.0 mm thick. fixing 50 mm x 6 mm, 3 mtrs G.I, strips from G.I.plate to earth terminal including brazing / welding at plate etc. Supplying and laying in position 19 mm, 2 mtrs G.I. `B' class pipe for watering.with reducer/funnel with mesh. S/F of the following in the earth station. 75 Kg. Charcoal. 15 Kg. Original Salt. Black Cotton soil Construction of earth pit chamber including necessary brick work concrete, plastering, S/F of C.I. Cover of size 12" x 12" complete as per site req. 1 No. 21 COPPER PLATE EARTH STATION : Preparation of the Plate Earth Station: (as per IS:3043) Excavation of rocky earth, soft murrum, hard murrum etc and back filling with black cotton soil for the earth station, the earth pit size is 1000 mm x 1000 mm x 2500 mm deep. S/F of Copper plate of size 600 x 600 x 3.0 mm thick. fixing 50 mm x 6 mm, 3 mtrs Copper strips from G.I.plate to earth terminal including brazing / welding at plate etc. Supplying and laying in position 19 mm, 2 mtrs G.I. `B' class pipe for watering.with reducer/funnel with mesh. S/F of the following in the earth station. 75 Kg. Charcoal. 15 Kg. Original Salt. Black Cotton soil

5 Construction of earth pit chamber including necessary brick work concrete, plastering, S/F of C.I. Cover of size 12" x 12" complete as per site req. 1 No. 22 i) Providing and fixing Copper / GI strip as per specification complete including connection to earth electrode revetting / sweating / soldering, burying 15 cms below in all types of soil / rocks etc complete as a G.I.Strip 25 X 5 mm 25 Mtrs. b G.I.Strip 50 X 6 mm 5 Mtrs. c Copper Strip 25 X 5 mm 25 Mtrs. d Copper Strip 50 X 6 mm 5 Mtrs. ii) Supply and laying of following size hot dip G.I.wire from earth terminal at earth station to earth bus-bar / pole etc.or with the Cable on wall / 150 mm below ground level,wherever required as per site condition. a 6 SWG G.I.Wire 40 Mtrs. b 10 SWG G.I.Wire 50 Mtrs. 23 Supply and laying of 16 sqmm PVC insulated copper wire in 15 mm G.I. pipe including accessories complete as 40 RM GRAND TOTAL Signature of Contractor (With Seal of Firm)

E S T I M A T E TENDER FOR ELECTRICAL & DATA CABLING WORK FOR BANK OF INDIA, KALAWAD ROAD BRANCH(GROUND FLOOR)-RAJKOT CITY

E S T I M A T E TENDER FOR ELECTRICAL & DATA CABLING WORK FOR BANK OF INDIA, KALAWAD ROAD BRANCH(GROUND FLOOR)-RAJKOT CITY PART- IV - ELECTRIC WORK FOR BRANCH Supply, installation, testing and commissioning of following point wiring as per the specifications and drawings. The unit rate for the switch board and further to point

More information

Schedule of Quantities

Schedule of Quantities CIVIL WORK (A) 1 Providing and fixing corrugated galvanised iron sheets of 20 B.W.G. for roofing with wind ties including fastening with galvanised iron screw and bolts and lead and bitumen washers as

More information

TECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR

TECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR TECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR 1.0 GENERAL REQUIREMENTS The installation shall generally be carried out in conforming with the requirements of the Indian Electricity

More information

MAHARSHI DAYANAND UNIVERSITY ROHTAK (A State University established under Haryana Act No. 25 of 1975) NAAC accredited A Grade

MAHARSHI DAYANAND UNIVERSITY ROHTAK (A State University established under Haryana Act No. 25 of 1975) NAAC accredited A Grade MAHARSHI DAYANAND UNIVERSITY ROHTAK (A State University established under Haryana Act No. 25 of 1975) NAAC accredited A Grade NOTICE INVITING TENDER Sealed tenders on item basis are invited on behalf of

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: -

DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: - PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATION -SITE 01 DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: - 1.0 Final sub-circuit from Consumer Unit to lighting

More information

NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION

NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION NCRMI/LIB/ELE001/15 4.09.2015 Competitive sealed quotations are invited

More information

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST ANNEXURE I Sl.No. Description for BHEL Requirement Offered Deviation Scope of supply, erection and commissioning: 1 The scope of this specification covers

More information

ELECTRICAL WORKS FOR CPCB ZONAL OFFICE AND LABORATORY AT BANGALORE. Consultants: SRIMATHA ENTERPRISES

ELECTRICAL WORKS FOR CPCB ZONAL OFFICE AND LABORATORY AT BANGALORE. Consultants: SRIMATHA ENTERPRISES Item No. BILL OF QUANTITIES WITH SPECIFICATIONS - ELECTRICALS Qty. Unit Rate Description 1.0 415VOLTS MAIN DISTRIBUTION BOARDS CONSTRUCTION (i) Sheet steel - 2mm thick for frames and equipment mounting

More information

PART-II (COMMERCIAL / PRICE BID) DESIGN, SUPPLY AND INSTALLATION OF CUSTOMIZED STEEL LAB FURNITURE.AT N.C.C.S., PUNE

PART-II (COMMERCIAL / PRICE BID) DESIGN, SUPPLY AND INSTALLATION OF CUSTOMIZED STEEL LAB FURNITURE.AT N.C.C.S., PUNE (An Autonomous Institution of the Department of Biotechnology, Govt. of India) N.C.C.S. Complex, Ganeshkhind, Pune University Campus, Pune 411007. PART-II (COMMERCIAL / PRICE BID) DESIGN, AND INSTALLATION

More information

Financial Bid Format(All Inclusive)

Financial Bid Format(All Inclusive) Financial Bid Format(All Inclusive) Sl. N. Description In Figure Rate Per Unit In Words 1 ROUTER TYPE A 2 ISP LINK LOAD BALANCER 3 INTERNET SECURITY 4 ROUTER TYPE B 5 USER & DEVICE IDENTITY MANAGEMENT

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

STATE BANK OF INDIA.

STATE BANK OF INDIA. Page 1 of 5 B SANITARY, PLUMBING & DRAINAGE STATE BANK OF INDIA. PROPOSED RURAL SELF EMPLOYMENT TRAINING INSTITUTE AT RAIGARH IN C.G. DIRECTOR'S BUNGALOW SCHEDULE OF ITEMS-PLUMBING AND SANITARY WORK 1

More information

Bill of Quantities. Factory Services Date: 23.08.2010

Bill of Quantities. Factory Services Date: 23.08.2010 Factory Services Date: 23.08.2010 Bill of Quantities 1. All items of work under this Contract shall be executed strictly to fulfill the requirements laid down under Basis of Design in the specifications.

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

SCHEDULE OF RATE FOR ARC FOR MAINTENANCE OF CP & ASSOCIATED SYSTEM FOR HVJ, DVPL - I and DVPL - II PIPELINE UNDER KHERA PIPELINE JURISDICTION

SCHEDULE OF RATE FOR ARC FOR MAINTENANCE OF CP & ASSOCIATED SYSTEM FOR HVJ, DVPL - I and DVPL - II PIPELINE UNDER KHERA PIPELINE JURISDICTION SCHEDULE OF RATE FOR ARC FOR MAINTENANCE OF CP & ASSOCIATED SYSTEM FOR HVJ, DVPL - I and DVPL - II PIPELINE UNDER KHERA PIPELINE JURISDICTION THE RATES QUOTED SHALL BE INCLUSIVE OF MATERIAL AND LABOUR

More information

BOQ for Plumbing, Sanitary Works

BOQ for Plumbing, Sanitary Works BOQ for Plumbing, Sanitary Works Page 1 of 6 Sr.No Item Description Quantity Unit Rate Amount (Rs.) 1 SANITARY FIXTURES Providing & Fixing star white colour vitreous china wall mounted wc with 1a heavy

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

SUBHEAD-I: POINT WIRING & SUBMAIN WIRING. Ru-Tech Services Inc. Page-1 Electrical BOQ.xls

SUBHEAD-I: POINT WIRING & SUBMAIN WIRING. Ru-Tech Services Inc. Page-1 Electrical BOQ.xls SUBHEAD-I: POINT WIRING & SUBMAIN WIRING 1.1 Wiring for light Point/ fan point/ exhaust fan point/ call bell point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed

More information

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition. DIVISION 15 MECHANICAL SECTION 15100 - PLUMBING PART 1 - GENERAL SCOPE Plumbing work includes all domestic water, gas, and sanitary sewer systems as shown on plans. Also all fixtures and equipment which

More information

FOR ELECTRICAL WORK TECHNICAL BID ISSUED TO :

FOR ELECTRICAL WORK TECHNICAL BID ISSUED TO : PROJECT : INTEGRATED DEVELOPMENT OF KABIRWAD AT MANGLESHWAR, BHARUCH. CLIENT : BHARUCH COLLECTOR OFFICE ARCHITECT : AD MOBEL, AHMEDABAD. ELECTRICAL CONSULTANTS: PRABHAS ENGINEERS CONSULTANTS : BENCHMARK

More information

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements 16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications

More information

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET

More information

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications

More information

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE Sl.No. PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE Description of item Qty Unit Rate Amount 1 Demolishing tile work/cement concrete/( carefully taking out the closet and other

More information

TECHNICAL SPECIFICATION FOR HIGH MAST LIGHTING SYSTEM, 20 MTRS HEIGHT

TECHNICAL SPECIFICATION FOR HIGH MAST LIGHTING SYSTEM, 20 MTRS HEIGHT TECHNICAL SPECIFICATION FOR HIGH MAST LIGHTING SYSTEM, 20 MTRS HEIGHT Annexure A Sl.No. Description 1 Scope: The scope cover the design, manufacturing, supply and delivery at GCF Jabalpur on FOR basis

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT 1.1 General 1.1.1 These Special Conditions of Contract supplement the General Instructions.

More information

Distribution Boards & Consumer Units

Distribution Boards & Consumer Units Distribution Boards & Consumer Units Enclosures for system pro M compact Distribution Boards & Consumer Units Contents General 2/ Distribution Boards Mini Center compact Mounting kits for compact accessories

More information

SECTION 16760 - PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines

SECTION 16760 - PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines PART 1 - GENERAL SECTION 16760-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing plant intercommunication systems with power supplies, signal amplifiers,

More information

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264 BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used

More information

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6 050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY

More information

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

JAWAHARLAL NEHRU UNIVERSITY

JAWAHARLAL NEHRU UNIVERSITY School of Biotechnology JAWAHARLAL NEHRU UNIVERSITY New Delhi 110 067 Tender No. JNU/SBT/DBT-BUILDER/Data Centre/2015-16 Sealed Quotation for the establishment of a Data Centre for High-End Computational

More information

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS This guideline has been prepared to assist the owner/occupant of a single family dwelling with compliance to the requirements of the National Electrical

More information

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

BILL OF QUANTITY FOR THE WORK OF REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP" Sl. 1 DISMANTLING WORK 1.1 Stripping off worn out plaster (outside and inside) and raking out joints

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin January 2016 CEC-10 [rev-9] Page 1 of 8 CANADIAN ELECTRICAL CODE SUBJECT: Section 10 Grounding and Bonding Rule 10-204 Grounding Connections for Alternating-Current

More information

Installation Manual For Support Call 01704 807114 or email info@hipentertainment.co.uk

Installation Manual For Support Call 01704 807114 or email info@hipentertainment.co.uk Installation Manual Hip Smart Hub (Standard BT and BT FTTP Sites) The Home Network Hub houses the Home Owner s Broadband Router and connects the hardwired network ports on that Router to three network

More information

19" GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN

19 GERMANY EXPORT RACK QUALITY PRODUCT FOR THE BEST WORK NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN NEW DESIGN CABLE MANAGEMENT PANEL WALL RACK CABINET 15 U VENTILATING FAN AC SOCKET STRIP (AC Power Distribution) BLANK PANELS x U OPEN RACK THERMOSTAD PANEL SET CABLE MANAGEMENT PANEL WITH COVER BAYING

More information

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Whitepaper Modular Substation Cable Termination Design Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Abstract The methods for cable penetrations into modular industrial substations are

More information

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4. Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s

More information

ScottishPower Distribution Cables & Equipment. Metal Theft

ScottishPower Distribution Cables & Equipment. Metal Theft ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated

More information

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad PLEASE MARK TICK ON LEFT BOX WHICH EQUIPMENT YOU HAVE QUOTED PROPOSAL BASED ON CHINESE EQUIPMENT

More information

SPECIFICATIONS FOR VASWANI BRENTWOOD PROJECT. RCC Framed Structure confirming with zone II seismic detailing. Reinforced Cement Concrete

SPECIFICATIONS FOR VASWANI BRENTWOOD PROJECT. RCC Framed Structure confirming with zone II seismic detailing. Reinforced Cement Concrete SPECIFICATIONS FOR VASWANI BRENTWOOD PROJECT 1. CONSTRUCTION: Foundation Super Structure Internal Walls External Walls Roof Retaining Walls RCC footing RCC Framed Structure confirming with zone II seismic

More information

IT&T Infrastructure Standards

IT&T Infrastructure Standards Technology Services IT&T Infrastructure Standards Version 1.5 17 th April 2015 Page 1 Table of contents 1 CHANGE HISTORY... 3 1.1 DOCUMENT HISTORY... 3 1.2 REVIEWERS... 3 1.3 APPROVALS... 3 2 INTRODUCTION...

More information

800 Communications Circuits

800 Communications Circuits ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that

More information

NATIONAL INSTITUTE OF BIOLOGICALS

NATIONAL INSTITUTE OF BIOLOGICALS Short Term Notice Inviting Quotations Quotations No. S.1-36/07/NIB/Engg. (Civil) Invitation to short term quotations for Repairing of damaged gypsum board false ceiling and painting with epoxy paint in

More information

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS 1. Standards BOS Item / System I ii iii TECHNICAL SPECIFICATIONS Applicable BIS /Equivalent IEC Standards / Applicable MNRE Specifications Standard Description Standard Number Crystalline Silicon Terrestrial

More information

Structured Cabling, Earthing & Equipotential Bonding

Structured Cabling, Earthing & Equipotential Bonding White Paper Information and Communication Technology Structured Cabling, Earthing & Equipotential Bonding English Rev. 1.0.1 / 2012-06-01 1 Abstract All Dallmeier network products (PoE cameras, recorders,

More information

SECTION 25110 TELECOMMUNICATION ROOMS

SECTION 25110 TELECOMMUNICATION ROOMS PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication

More information

**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT

**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT **ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT. YOU COULD PUT YOUR FAMILY AND WORLDLY POSSESSIONS IN DANGER!!!

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

Linkeo 19" freestanding cabinets

Linkeo 19 freestanding cabinets 87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3

More information

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping. BOQ SPECIFICATIONS VERTICAL BLINDS Vertical Blinds made of glass fibre fabrics in width 5 (or 4 ). Minimum overlapping of ¾ in fabric. Top aluminium anodized rail of 1.4 mm thickness. 2 inch wide channel

More information

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute

More information

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black USB.0 CableS USB.0 and backwards compatible for USB.0 and. Supports high speed, 480Mbps Twisted-pair construction reduces cross talk to ensure error free transfer USB A male to USB B male 00-0 007-0 0-09-

More information

Tender for Converting existing canteen to Information Security Laboratory - Electrification works. : Valid license issued by KSEI or PWD Electrical

Tender for Converting existing canteen to Information Security Laboratory - Electrification works. : Valid license issued by KSEI or PWD Electrical Tender for Converting existing canteen to Information Security Laboratory - Electrification works Owner Cost of tender document EMD Time of completion : The Director IIITM-K, Technopark Campus, Thiruvananthapuram

More information

Electrical Practices for Construction Work

Electrical Practices for Construction Work 1. Purpose Electrical Practices for Construction Work The purpose of this Code is to provide practical guidance and set minimum safety requirements for electrical practices on all construction sites in

More information

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM 7/00 INSTALLATION INSTRUCTION SPEC. SHEET 99052 99063 City of New York Calendar #40747 Copyright c 2000 ALFA Lighting, Inc. All rights reserved. Call:1-415-975-8080 QUICK JACK QJS R LISTED 9901483 ETL

More information

Distribution Boards. A perfect blend of aesthetics, functionality and safety

Distribution Boards. A perfect blend of aesthetics, functionality and safety Distribution Boards A perfect blend of aesthetics, functionality and safety ABB a global leader Distribution Boards ABB (www.abb.com) is a global leader in power and automation technologies that enable

More information

A. Shop Drawing submittals shall include, but not be limited to, the following:

A. Shop Drawing submittals shall include, but not be limited to, the following: SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical

More information

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow

More information

Session 14 Cable Support Systems

Session 14 Cable Support Systems Session 14 Cable Support Systems Cable Support Systems in the IEC World A new IEC Standard, IEC61537 2001 has been developed If full details of the cabling layout are available then the likely cable load

More information

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: Signed completed Electrical Permit application form. Minnesota law requires all electrical work is to be performed by licensed,

More information

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS ~GSM SHELTER CONTAINERS ARE PROCUDED ACCORDING TO THE DEMANDED SIZE.~ (W x L x H) Page1 GENERAL FEAUTURES Environmental Conditions : Maximum outdoor temperature

More information

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications. Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment

More information

GENERAL ELECTRICAL REQUIREMENTS

GENERAL ELECTRICAL REQUIREMENTS GENERAL ELECTRICAL REQUIREMENTS RECEPTACLE SPACING Within 6-feet of the edge of any door HABITABLE Not more than 12-feet apart along wall ROOMS: At all wall spaces 24 or more wide Within 24 of edge of

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

Minimum Standards for Data/Voice Infrastructure in New Building Construction

Minimum Standards for Data/Voice Infrastructure in New Building Construction UNIVERSITY OF WATERLOO Minimum Standards for Data/Voice Infrastructure in New Building Construction 12/17/2012 Offices 1. Two Work Area Outlets (WAO) on opposite walls, each with 2 jacks 2. Each WAO shall

More information

KAM 25-32 A Lighting Busbar System KAP 40-63 A Plug-in Busbar Distribution System

KAM 25-32 A Lighting Busbar System KAP 40-63 A Plug-in Busbar Distribution System 2-32 A Lighting Busbar System 4-63 A Plug-in Busbar Distribution System / E-LINE KX Compact Busbar Distribution System 63...63 A E-LINE KB Compact Busbar Distribution System 8...63 A E-LINE KO Plug-in

More information

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major

More information

Broadway 3D Security System

Broadway 3D Security System Broadway 3D Security System USER MANUAL v.1.1.0 Artec Group, Inc. 2012 Table of contents 1. General Information... 3 2. Delivery Package... 4 3.1. B3D BR... 5 3.2. B3D B... 6 3.3. B3D BM... 7 4. Integration

More information

Turnkey Projects, Conversions, Restorations & Property Management. Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE

Turnkey Projects, Conversions, Restorations & Property Management. Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE Turnkey Projects, Conversions, Restorations & Property Management Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE Reg. Office: Karlu Galea Street, Victoria, Gozo Malta. T. 2155 6600 M. 9943 4391

More information

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE Applies to Models: 75W, 150W, 300W, 600W, 900W, 1200W ATTENTION: Please read this guide carefully to ensure safe and efficient

More information

Network Standard Advice No. 1420C 9/6/2011

Network Standard Advice No. 1420C 9/6/2011 Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides

More information

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12 SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications

More information

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final

More information

Preamble To Schedule A

Preamble To Schedule A PRICE BID Page 1 of 6 Preamble To Schedule A 1) The quantities given in schedule A are purely for guidance of the contractor to enable him to quote the rates. The quantities can be varied to any extent,

More information

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

Switchboard system. NorLine 800

Switchboard system. NorLine 800 Switchboard system NorLine 800 NorLine 800 SWITCHBOARD SYSTEM 2 NorLine 800 Switchboard system Table of contents Subject Page Table of contents 2 Overview 2-3 NorLine 800 technical specifications 4 Structural

More information

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. 1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking

More information

6000 Series Buccaneer

6000 Series Buccaneer Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available

More information

PROPOSED INTERIOR FURNISHING, ELECTRIC & AIR CONDITIONING WORKS AT EXPORT CREDIT GURANTEE CORPORATION OF INDIA LTD., BO: JODHPUR.

PROPOSED INTERIOR FURNISHING, ELECTRIC & AIR CONDITIONING WORKS AT EXPORT CREDIT GURANTEE CORPORATION OF INDIA LTD., BO: JODHPUR. PROPOSED INTERIOR FURNISHING, ELECTRIC & AIR CONDITIONING WORKS AT EXPORT CREDIT GURANTEE CORPORATION OF INDIA LTD., BO: JODHPUR. S.NO. PARTICULARS. AMOUNT ( IN Rs.) 1. Part A FURNISHING WORK Rs. 2. Part

More information

Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI

Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI TENDER CLARIFICATIONS- no 3 dated 3rd Oct 13 issued in response

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE

CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE 8.1 SYSTEM 8.1.1 Armoured, screened underground cables are used for control communication in electrified areas to limit induction effect. 8.2

More information

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

EARTHING AND BONDING AT SECONDARY SUBSTATIONS DISTRIBUTION CONSTRUCTION MANUAL SECTION 4 - SUBSTATIONS ISSUE B SEPT 1996 4.4.4 EARTHING AND BONDING AT SECONDARY SUBSTATIONS 1 SCOPE This section of the Distribution Construction Manual lays down the

More information

ST. MONICA FOOD PANTRY HOUSTON, TEXAS

ST. MONICA FOOD PANTRY HOUSTON, TEXAS PROJECT MANUAL FOR ST. MONICA FOOD PANTRY HOUSTON, TEXAS OWNER: ST. MONICA CATHOLIC CHURCH 8421 W. MONTGOMERY ROAD HOUSTON, TEXAS 77088 ARCHITECT: C SIX ARCHITECTURE, LLC 4606 F.M. 1960 WEST, STE 400 HOUSTON,

More information

Cat7/Class F New Installation Concept New infrastructure. Handbook

Cat7/Class F New Installation Concept New infrastructure. Handbook Cat7/Class F New Installation Concept New infrastructure Handbook contents 1 Introduction 3 2 What is the Cat7/Class F installation concept 3 3 Distribution centre 3 3.1 Patch Modules 3 4 How to handle

More information

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE 86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is

More information

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS 13.1 13.2 2006 Edition SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS GENERAL

More information

AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding

AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding A Guide for California Developers of Com m ercial Property This guide consists of

More information

Power Supply Cables and Connectors

Power Supply Cables and Connectors Power Supply Cables and Connectors Often during the excitement of designing a challenging new system, some of the more mundane engineering aspects get overlooked. This is especially true of connections

More information

TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC)

TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC) TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC) Prepared by Committee for Technology Assessment and Analyzing the installation of Solar Water Heater Systems in Government

More information

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST 0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL

More information

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT Active Speaker System with remote input LX523 User Manual & Installation Guide AUDAC PROFESSIONAL AUDIO EQUIPMENT User Manual & Installation

More information

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval. Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's

More information

Schedule-4(A3) Page 1 of 5. Specification No.: JPL/KWTL/A3 (Package-A3) To: Bidder's Name & Address

Schedule-4(A3) Page 1 of 5. Specification No.: JPL/KWTL/A3 (Package-A3) To: Bidder's Name & Address Specification : JPL/KWTL/A3 (Package-A3) Page 1 of 5 Tower Package (Package-A3) for 400 kv D/C (Quad Bundle) Karcham Wangtoo Abdullapur Line Part III associated with Karcham Wangtoo HEP Transmission System

More information