1 PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATION -SITE 01 DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way 2 switching 2.0 Ditto but for 2 way switching No Install light switches as MK or Crabtree a. 6A one gang one way No. 6 b. 6A Two gang one way No. 0 c. 6A one gang two way 0 d. 6A Two gang two way No. 2 e. 6A Three gang two way No Light fitting complete with internal wiring and control gear only a. Type C No 3 b. Type 2 c. Type 1 No. 9 d. Type W e. Type S Final ring circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit Radial circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit No. 9 No Install accessories as MK or Crabtree a. TV outlet plates No. 2 b. 13A Twin switched socket outlet plates No. 9 c. Blanking Plates at DATA Outlet Points No. 2 d. 20A D.P power switch with neon light indicator No. 3 Supplly and install conduit outlet points in 25 mm 8.0 diameter terminating with draw wire to the following points. a. TV outlet points No. 2 b. DATA outlet points A Electric cooker final sub-circuit comprising of 3 x 6mm sq sc copper cables drawn in 25mm diameter concealed pvc conduit Supply and install a cooker control unit 45 Amps Supply and install a 45A cooker connector TOTAL CARRIED FORWARD TO NEXT PAGE Page Page 1

2 PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATION -SITE 01 DESCRIPTION UNIT QTY RATE TOTAL KSHS BAL B/F way SPN MCB recessed consumer unit incorporating 60 A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's 13.0 Miniature circuit breaker a 10A Single pole No. 2 b 20A Single pole c 30 A Single pole No. 3 d Blanking plates No /1000V grade single core pvc insulated copper cables to B.S 6346 drawn in pvc ducts from Meterboard to consumer unit a. 3 x 16mm 2 sc cu cables drawn in 32mm dia pvc conduit from Consumer Unit to meterboard at staircase area LM Supply and Install a 20mm diameter conduit from meterboard to position of control pad for KPLC Ltd prepaid Meter c/w 2 x 1.01 mm sq. cu cables(30m) Item Supply and Install a blanking plate for the above at the position of the prepaid meter Item Supply and Install 2.5Sq mm twin + earthcables between the 20 Amps d.p. switch and the water heater Lm 20 Total for 1No. Apartment X30 Nos. Total for 30 No. Apartments (3 Blocks) TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 7 Page 2

3 PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATION FOR TO COMMON AREAS (Staircase and Security lighting) DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Supply and install the following. 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 2.5mm sq sc copper cables drawn in 20mm diameter concealed conduit for two way switching. No Install light switches as MK or Crabtree a. 6A 1 gang one way No 1 b. 6A 1 gang 2 way No. 2 c. 6A intermediate switch No Light fitting complete with internal wiring and control gear only a. TYPE 2D 0 b. Type B Final Ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm 2 sc copper cables drawn 20mm diameter Hq concealed conduit. No. 5 a. 13A Twin switched socket outlet plates. No 5 b. 13A switched and fused spur unit for security and Telephone and communication Telephone equipment. Supply and install surge protection for item 'b' above. No way SPN MCB recessed consumer unit incorporating 60 A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's No 1 a. Miniature circuit breaker b. 10 A single pole No. 3 c. 20 A single pole d. 30A single pole. No Photocell with mounting brackets A SPN contactor relay. Water Booster Pump 8.0 Power point for domestic water booster pump comprising of 3 x 4 mm sq sc cu cable complete with 13A fused and switch spur unit X150X50mm Adaptable boxes 0 Total for 1 No. Block Total for 3 No. Blocks TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 7 Page 3

4 PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 MAIN METERBOARD AT STAIRCASE AREA DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Weatherproof wall semi-recessed meter board 1.0 fabricated from G16steel sheet,powder coated lockable with all necessary accessories and adquate space for the following switchgear a. 200A TPN MCCB (Main incomer) b. 200A TPN 4 pole cu bus-bar item 1 c. 60A SPN MCB (High Rapturing Capacity) 1 d. KPL Single phase meters (space only) 1 e. KPL Single phase cutouts (space only) 1 f. Earth bar item 1 g. All internal cabling. Item 1 h Space for common service 6 Way Consumer Unit Item 1 Earthing 2.0 Eathing point to comprise of the following, a. 15mm dia x 1500mm long copper earth electrode with connector clamp b. Driving head c. 16 mm sq copper earth lead in 20mm dia conduit No. Item d. Concrete Earth Manhole with cover No. Item e. Provisional sum for Earthing improvement if necessary No. Item 3.0 Testing a. Testing of the whole installation to conform to No. item I.E.E Regulations 4.0 Supply and Lay in vertical riser 200 x 50 mm sheet steel cable tray with brackets at 1m intervals complete with cable cleats Lm 15 Total for 1No. Block x 3Nos Total for 3 No. Blocks TOTAL FOR METERBOARD CARRIED FORWARD TO COLLECTION..Page 7 Page 4

5 PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATIONS TV INSTALLATION DESCRIPTION UNIT QTY RATE TOTAL KSHS Supply,install, test & commission the following Way multiswitch as Televes Amps Power surge protection as Sollateck for the multiswitch 3.0 Aerial mast to carry the following high quality 2No. UHF reception aerials complete with mounting brackets and bolts. 4.0 DSTV Dish 5.0 Co-axial cable 100m rolls (Heavy duty) for 1No. Block of apartments No Provide a rate for pulling and connection of cables from TV aerial/dstv Dish to multiswitch and to TV outlets at 30 No. flats Item Allow for testing and commissioning of the installation No Item 8.0 Allow for any other items not covered in the bill to make the TV installation complete. No item way splitter unit No Supply and lay 200 x 50mm factory built cable tray complete with accessories LM 15 TOTAL FOR ALL 3 NO BLOCKS TOTAL FOR TV INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 7 Page 5

6 PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATIONS LIGHTNING PROTECTION DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply,install, test and commission the following items : Suppy and Install a lightning protection 25 x 3mm copper tape as specified and indicated on the drawing Lm Suppy and Install a 15mm diameterx1800mm copper coated earth rods as specified and indicated in the drawing 3.0 Copper lightning arrester(air termination),stem,and base on the roof,with the base fastened squarely on the ridge of the roof,inclusive of the base clamps and all fixing materials. 4.0 Supply and Install a block for 25 mm tape as specified and indicated in the drawings. No. 2 No. 2 No Roof conductor Support at 2m intervals No 11 Test Clamp as Furse Cross Coupler No Tape Clamping Brackets at 1m intervals No Copper plated steel grounding rods 2Mx14mm No Electrode ground connection No Testing and Commissioning item Price for any other item to complete the installation; list below item 1 TOTAL FOR 1No. BLOCK - x 3Nos. TOTAL FOR 3No. BLOCKS - TOTAL CARRIED TO PRICE COLLECTION PAGE..Page 7 - Page 6

7 PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATION WORKS COLLECTION PAGE FOR 3 No. BLOCKS DESCRIPTION TOTAL KSHS NO 1.00 Total B/F from page Total B/F from page Total B/F from page Total B/F from page Total B/F from page 6 Total for 3 NO BLOCKS TOTAL CARRIED FORWARD TO SUMMARY PAGE Page 35 Page 7

8 PROPOSED KISUMU HOUSING 3,2 BEDROOM UNITS ELECTRICAL INSTALLATION -SITE 01 3 BEDROOM-TYPE 2 Supply and install the following: - DESCRIPTION UNIT QTY RATE TOTAL (KSHS) 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way No. 8 switching 2.0 Ditto but for 2 way switching No Install light switches as MK or Crabtree a. 6A one gang one way No. 5 b. 6A Two gang one way c. 6A one gang two way No. 8 d. 6A Two gang two way e. 6A Three gang two way 4.0 Light fitting complete with internal wiring and control gear only a. Type C No 3 b. Type 2 c. Type 1 No. 7 d. Type W No. 0 e. Type S No Final ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit No Radial circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit No Install accessories as MK or Crabtree a. T.V outlet points No. 2 b. 13A Twin switched socket outlet plates No. 8 c. Blanking Plates at DATA outlet points d. 20A D.P power switch with neon light indicator No Supplly and install conduit outlet points in 25 mm diameter terminating with draw wire to the following points. a. TV outlets points No. 2 b. DATA outlet points A Electric cooker final sub-circuit comprising of 3 x 6mm sq sc copper cables drawn in 25mm diameter concealed pvc conduit Supply and install a cooker control unit 45 Amps Supply and install a 45A cooker connector TOTAL CARRIED FORWARD TO NEXT PAGE Page 9 Page 8

9 PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS ELECTRICAL INSTALLATION -SITE 01 3 BEDROOM-TYPE 2 DESCRIPTION UNIT QTY RATE TOTAL KSHS BAL B/F way SPN MCB recessed consumer unit incorporating 60A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's 12.0 Miniature circuit breaker a 10A Single pole No. 2 b 20A Single pole c 30 A Single pole No. 3 d Blanking cover No /1000V grade single core pvc insulated copper cables to B.S 6346 drawn in pvc ducts from Meterboard to consumer unit a. 3 x 16mm 2 sc cu cables drawn in 32mm dia pvc conduit from Consumer Unit to meterboard at staircase area LM Supply and Install a 20mm diameter conduit from meterboard to position of control pad for KPLC Ltd prepaid Meter c/w 2 x 1.02 mm sq. cu cables(30m) Supply and Install a blanking plate for the above at the position of the prepaid meter Item 1 Item Supply and Install 2.5Sq mm twin + earthcables between the 20 Amps d.p. switch and the water heater Lm 20 Total for 1No. 3Bedroom Apartment x 10 Nos. Total for 10 No. Apartments (1 Block) TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 16 Page 9

10 PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS ELECTRICAL INSTALLATION -SITE 01 2 BEDROOM DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way No. 6 switching 2.0 Ditto but for 2 way switching No Install light switches as MK or Crabtree a. 6A one gang one way No. 4 b. 6A Two gang one way c. 6A one gang two way No. 3 d. 6A Two gang two way e. 6A Three gang one way No. 0 f. 6A Three gang two way No Light fitting complete with internal wiring and control gear only a. Type C No 2 b. Type 2 c. Type 1 No. 6 d. Type W No. 0 e. Type S No Final ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit Radial circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit No. 5 No Install accessories as MK or Crabtree a. TV outlet plates No. 2 b. 13A Twin switched socket outlet plates No. 5 c. Blanking Plates at Data Outlet Points No. 2 d. 20A D.P power switch with neon light indicator No Supplly and install conduit outlet points in 25 mm diameter with draw wire to the following points. a. TV outlet points b. DATA outlet points A Electric cooker final sub-circuit comprising of 3 x 6mm sq sc copper cables drawn in 25mm diameter concealed pvc conduit Supply and install a cooker control unit 45 Amps Supply and install a 45A cooker connector TOTAL CARRIED FORWARD TO NEXT PAGE Page 11 Page 10

11 PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS ELECTRICAL INSTALLATION -SITE 01 2 BEDROOM DESCRIPTION UNIT QTY RATE TOTAL KSHS BAL B/F way SPN MCB recessed consumer unit incorporating 60A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's 13.0 Miniature circuit breaker a 10A Single pole No. 2 b 20A Single pole c 30 A Single pole No. 2 d Blanking cover /1000V grade single core pvc insulated copper cables to B.S 6346 drawn in pvc ducts from Meterboard to consumer unit a. 3 x 16mm 2 sc cu cables drawn in 32mm dia pvc conduit from Consumer Unit to meterboard at staircase area LM Supply and Install a 20mm diameter conduit from meterboard to position of control pad for KPLC Ltd prepaid Meter c/w 2 x 1.01 mm sq. cu cables(30m) Supply and Install a blanking plate for the above at the position of the prepaid meter Supply and Install 2.5Sq mm twin + earthcables between the 20 Amps d.p. switch and the water heater Item 1 Item 1 Lm 5 Total for 1No. 2 Bedroom Apartment X30 Nos. Total for 30 No. Apartments (1 Block) TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 16 Page 11

12 PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS ELECTRICAL INSTALLATION FOR TO COMMON AREAS (Staircase and Security lighting) DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Supply and install the following. 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 2.5mm sq sc copper cables drawn in 20mm diameter concealed conduit for two way switching. No Install light switches as MK or Crabtree a. 6A 1 gang one way No 4 b. 6A 1 gang 2 way No. 4 c. 6A 2 Intermediate Switch No Light fitting complete with internal wiring and control gear only a. TYPE 2D No. 20 b. Type B Final Ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm 2 sc copper cables drawn 20mm diameter Hq concealed conduit. 0 a. 13A Twin switched socket outlet plates. No 10 b. 13A switched and fused spur unit for security and Telephone and communication Telephone equipment. Supply and install surge protection for item 'b' above. No way SPN MCB recessed consumer unit incorporating 60 A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's No 2 a. Miniature circuit breaker b. 10 A single pole No. 4 c. 20 A single pole No. 2 d. 30A single pole. No. 4 e Blanking Plate No Photocell with mounting brackets. No A SPN contactor relay. No. 2 Water Booster Pump 8.0 Power point for domestic water booster pump comprising of 3 x 4 mm sq sc cu cable complete with 13A fused and switch spur unit. No X150X50mm Adaptable boxes 0 TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 16 Page 12

13 PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS MAIN METERBOARD AT STAIRCASE AREA DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Weatherproof wall semi-recessed meter board 1.0 fabricated from G16steel sheet,powder coated lockable with all necessary accessories and adquate space for the following switchgear a. 315A TPN MCCB (Main incomer) b. 315A TPN 4 pole cu bus-bar item 1 c. 60A SPN MCB (High Rapturing Capacity) No. 21 d. KPL Single phase meters (space only) No. 21 e. KPL Single phase cutouts (space only) No. 21 f. Earth bar item 1 g. All internal cabling. Item 1 h Space for common service 8Way Consumer Unit Item 1 Earthing 2.0 Eathing point to comprise of the following, a. 15mm dia x 1500mm long copper earth electrode with connector clamp b. Driving head c. 25 sq mm sq copper earth lead No. Item d. Concrete Earth Manhole with cover No. Item e. Provisional sum for Earthing improvement if necessary No. Item 3.0 Testing a. Testing of the whole installation to conform to No. item I.E.E Regulations 4.0 Supply and Lay in vertical riser 200 x 50 mm sheet steel cable tray with brackets at 1m intervals complete with cable cleats LM 15 Sub-Total For 1 No. Meterboard item 1 X2 Nos. For 2 Nos Meterboards Total Meterboard installation. Cost for 40 No. Apartments (1 Block) TOTAL FOR METERBOARD C /F TO BLOCK COLLECTION PAGE Page 16 Page 13

14 PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS ELECTRICAL INSTALLATIONS TV INSTALLATION DESCRIPTION UNIT QTY RATE TOTAL KSHS Supply,install, test & commission the following Way multiswitch as Televes Way Splitter as Televes No Amps Power surge protection as Sollateck for the multiswitch 4.0 Aerial mast to carry the following high quality 2No. UHF reception aerials complete with mounting brackets and bolts. 5.0 DSTV Dish 6.0 Co-axial cable 100m rolls (Heavy duty) for 1No. Block of 40 apartments No Provide a rate for pulling and connection of cables from TV aerial/dstv Dish to multiswitch and to TV outlets at 20 No. units Item Allow for testing and commissioning of the installation No Item 9.0 Allow for any other items not covered in the bill to make the TV installation complete. No item Sub-Total for 20 No. Apartments X2 Nos. For 40 Nos. Apartments in 1 Block TOTAL FOR TV INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 16 Page 14

15 PROPOSED KISUMU HOUSING ELECTRICAL INSTALLATIONS LIGHTNING PROTECTION DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply,install, test and commission the following items : Suppy and Install a lightning protection 25 x 3mm copper tape as specified and indicated on the drawing Lm Suppy and Install a 15mm diameterx1800mm copper coated earth rods as specified and indicated in the drawing 3.0 Copper lightning arrester(air termination),stem,and base on the roof,with the base fastened squarely on the ridge of the roof,inclusive of the base clamps and all fixing materials. 4.0 Supply and Install a block for 25 mm tape as specified and indicated in the drawings. No. 2 No. 2 No Roof conductor Support at 2m intervals No 11 Test Clamp as Furse Cross Coupler No Tape Clamping Brackets at 1m intervals No Copper plated steel grounding rods 2Mx14mm No Electrode ground connection No Testing and Commissioning item Price for any other item to complete the installation; list below item 1 TOTAL FOR 1No. BLOCK TOTAL FOR LIGHTNING PROTECTION INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 16 Page 15

16 PROPOSED KISUMU HOUSING 3 and 2 BEDROOM UNITS ELECTRICAL INSTALLATION WORKS COLLECTION PAGE DESCRIPTION TOTAL KSHS NO 1.00 Total B/F from page Total B/F from page Total B/F from page Total B/F from page Total B/F from page Total B/F from page 15 Total for 1 No. BLOCK x 4 Nos. Total for 4 No. BLOCKS TOTAL CARRIED FORWARD TO SUMMARY PAGE Page 35 Page 16

17 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION -SITE 01 DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way switching No Ditto but for 2 way switching No Install light switches as MK or Crabtree a. 6A one gang one way No. 3 b. 6A Two gang one way No. 0 c. 6A one gang two way No. 2 d. 6A Two gang two way e. 6A Three gang two way No Light fitting complete with internal wiring and control gear only a. Type C No 1 b. Type 2 c. Type 1 No Final Ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit No Radial circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit 7.0 Install accessories as MK or Crabtree a. TV outlet plates b. 13A Twin switched socket outlet plates No. 3 c. Blanking Plates at Data Outlet Points d. 20A D.P power switch with neon light indicator No Supplly and install conduit outlet points in 25 mm diameter terminating with draw wire to the following points. a. TV outlet points b. DATA outlet points A Electric cooker final sub-circuit comprising of 3 x 6mm sq sc copper cables drawn in 25mm diameter concealed pvc conduit Supply and install a cooker control unit 45 Amps Supply and install a 45A cooker connector TOTAL CARRIED FORWARD TO NEXT PAGE Page 18 Page 17

18 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION -SITE 01 DESCRIPTION UNIT QTY RATE TOTAL KSHS BAL B/F way SPN MCB recessed consumer unit incorporating 60A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's 13.0 Miniature circuit breaker a 10A Single pole b 20A Single pole c 30 A Single pole No. 2 d Blanking cover No /1000V grade single core pvc insulated copper cables to B.S 6346 drawn in pvc ducts from Meterboard to consumer unit a. 3 x 16mm 2 sc cu cables drawn in 32mm dia pvc conduit from Consumer Unit to meterboard at staircase area LM Supply and Install a 20mm diameter conduit from meterboard to position of control pad for KPLC Ltd prepaid Meter c/w 2 x 1.5 mm sq. cu cables(30m) Supply and Install a blanking plate for the above at the position of the prepaid meter Item 1 Item Supply and Install 2.5Sq mm twin + earthcables between the 20 Amps d.p. switch and the instant water heater Lm 5 Total for 1No. Apartment x 20 Nos. Total for 20 No. Apartments (1 Block) TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 23 Page 18

19 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION FOR TO COMMON AREAS (Staircase and Security lighting) DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Supply and install the following. 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 2.5mm sq sc copper cables drawn in 20mm diameter concealed conduit for two way No Install light switches as MK or Crabtree a. 6A 1 gang one way No 2 b. 6A 1 gang 2 way No. 2 c. 6A Intermediate Switch No Light fitting complete with internal wiring and control gear only a. TYPE 2D 0 b. Type B No Final Ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm 2 sc copper cables drawn 20mm diameter Hq concealed conduit. No. 5 a. 13A Twin switched socket outlet plates. No 5 b. 13A switched and fused spur unit for security and Telephone and communication Telephone equipment. Supply and install surge protection for item 'b' above way SPN MCB recessed consumer unit incorporating 60 A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's No 1 a. Miniature circuit breaker b. 10 A single pole No. 2 c. 20 A single pole d. 30A single pole. No. 2 e Blanking Plate 6.0 Photocell with mounting brackets A SPN contactor relay. Water Booster Pump 8.0 Power point for domestic water booster pump comprising of 3 x 4 mm sq sc cu cable complete with 13A fused and switch spur unit X150X50mm Adaptable boxes 0 TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 23 Page 19

20 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 MAIN METERBOARD AT STAIRCASE AREA DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Weatherproof wall semi-recessed meter board 1.0 fabricated from G16steel sheet,powder coated lockable with all necessary accessories and adquate space for the following switchgear a. 315A TPN MCCB (Main incomer) b. 315A TPN 4 pole cu bus-bar item 1 c. 60A SPN MCB (High Rapturing Capacity) No. 21 d. KPL Single phase meters (space only) No. 21 e. KPL Single phase cutouts (space only) No. 21 f. Earth bar item 1 g. All internal cabling. Item 1 h Space for common service 8Way Consumer Unit Item 1 Earthing 2.0 Eathing point to comprise of the following, a. 15mm dia x 1500mm long copper earth electrode with connector clamp b. Driving head c. 25 mm sq copper earth lead No. Item d. Concrete Earth Manhole with cover No. Item e. Provisional Sum For Earthing improvement if necessary No. Item 3.0 Testing a. Testing of the whole installation to conform to No. item I.E.E Regulations 4.0 Supply and Lay in vertical riser 200 x 50 mm sheet steel cable tray with brackets at 1m intervals complete with cable cleats Lm 15 TOTAL FOR METERBOARD C/F TO COLLECTION PAGE Page 23 Page 20

21 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATIONS TV INSTALLATION DESCRIPTION UNIT QTY RATE TOTAL KSHS Supply,install, test & commission the following Way multiswitch as Televes Amps Power surge protection as Sollateck for the multiswitch 3.0 Aerial mast to carry the following high quality 2No. UHF reception aerials complete with mounting brackets and bolts. 4.0 DSTV Dish 5.0 Co-axial cable 100m rolls (Heavy duty) for 1No. Block of 20 No. apartments No Provide a rate for pulling and connection of cables from TV aerial/dstv Dish to multiswitch and to TV outlets at 20 No. flats Item Way splitter units No Allow for testing and commissioning of the installation No Item 9.0 Allow for any other items not covered in the bill to make the TV installation complete. No item 10.0 Supply and lay 200 x 50mm factory built cable tray complete with accessories LM 15 TOTAL FOR TV INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 23 Page 21

22 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATIONS LIGHTNING PROTECTION DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply,install, test and commission the following items : Suppy and Install a lightning protection 25 x 3mm copper tape as specified and indicated on the drawing Lm Suppy and Install a 15mm diameterx1800mm copper coated earth rods as specified and indicated in the drawing 3.0 Copper lightning arrester(air termination),stem,and base on the roof,with the base fastened squarely on the ridge of the roof,inclusive of the base clamps and all fixing materials. 4.0 Supply and Install a block for 25 mm tape as specified and indicated in the drawings. No. 2 No. 2 No Roof conductor Support at 2m intervals No 11 Test Clamp as Furse Cross Coupler No Tape Clamping Brackets at 1m intervals No Copper plated steel grounding rods 2Mx14mm No Electrode ground connection No Testing and Commissioning item Price for any other item to complete the installation; list below item 1 TOTAL FOR 1No. BLOCK - TOTAL FOR LIGHTNING PROTECTION INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 23 Page 22

23 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION WORKS COLLECTION PAGE DESCRIPTION TOTAL KSHS NO 1.00 Total B/F from page Total B/F from page Total B/F from page Total B/F from page Total B/F from page Total for 1 NO BLOCK of 20 Apartments TOTAL CARRIED FORWARD TO SUMMARY PAGE Page 35 Page 23

24 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION -SITE 02 DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way switching No Ditto but for 2 way switching No Install light switches as MK or Crabtree a. 6A one gang one way No. 3 b. 6A Two gang one way No. 0 c. 6A one gang two way No. 2 d. 6A Two gang two way e. 6A Three gang two way No Light fitting complete with internal wiring and control gear only a. Type C No 1 b. Type 2 c. Type 1 No Final Ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit No Radial circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit 7.0 Install accessories as MK or Crabtree a. TV outlet plates b. 13A Twin switched socket outlet plates No. 3 c. Blanking Plates at Data Outlet Points d. 20A D.P power switch with neon light indicator 8.0 Supplly and install conduit outlet points in 25 mm diameter terminating with draw wire to the following points. a. TV outlet points b. DATA outlet points A Electric cooker final sub-circuit comprising of 3 x 6mm sq sc copper cables drawn in 25mm diameter concealed pvc conduit Supply and install a cooker control unit 45 Amps Supply and install a 45A cooker connector TOTAL CARRIED FORWARD TO NEXT PAGE Page 25 Page 24

25 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION -SITE 02 DESCRIPTION UNIT QTY RATE TOTAL KSHS BAL B/F way SPN MCB recessed consumer unit incorporating 60A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's 13.0 Miniature circuit breaker a 10A Single pole b 20A Single pole c 30 A Single pole No. 2 d Blanking cover No /1000V grade single core pvc insulated copper cables to B.S 6346 drawn in pvc ducts from Meterboard to consumer unit a. 3 x 16mm 2 sc cu cables drawn in 32mm dia pvc conduit from Consumer Unit to meterboard at staircase area LM Supply and Install a 20mm diameter conduit from meterboard to position of control pad for KPLC Ltd prepaid Meter c/w 2 x 1.5 mm sq. cu cables(30m) Supply and Install a blanking plate for the above at the position of the prepaid meter Item 1 Item Supply and Install 2.5Sq mm twin + earthcables between the 20 Amps d.p. switch and the instant water heater Lm 5 Total for 1No. Apartment x 20 Nos Total for 20 No. Apartments (1 Block) TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 30 Page 25

26 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION FOR TO COMMON AREAS (Staircase and Security lighting) DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Supply and install the following. 1.0 Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 2.5mm sq sc copper cables drawn in 20mm diameter concealed conduit for two way No Install light switches as MK or Crabtree a. 6A 1 gang one way No 2 b. 6A 1 gang 2 way No. 2 c. 6A Intermediate Switch No Light fitting complete with internal wiring and control gear only a. TYPE 2D 0 b. Type B No Final Ring-circuit from consumer unit to power outlet point comprising of 3 x 2.5mm 2 sc copper cables drawn 20mm diameter Hq concealed conduit. No. 5 a. 13A Twin switched socket outlet plates. No 5 b. 13A switched and fused spur unit for security and Telephone and communication Telephone equipment. Supply and install surge protection for item 'b' above way SPN MCB recessed consumer unit incorporating 60 A intergral isolator, lockable cover, labelling as Merlin Gerin but without mcb's No 1 a. Miniature circuit breaker b. 10 A single pole No. 2 c. 20 A single pole d. 30A single pole. No. 2 e Blanking Plate 6.0 Photocell with mounting brackets A SPN contactor relay. Water Booster Pump 8.0 Power point for domestic water booster pump comprising of 3 x 4 mm sq sc cu cable complete with 13A fused and switch spur unit X150X50mm Adaptable boxes 0 TOTAL CARRIED FORWARD TO COLLECTION PAGE Page 30 Page 26

27 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 MAIN METERBOARD AT STAIRCASE AREA DESCRIPTION UNITS QTY RATE TOTAL KSHS NO Weatherproof wall semi-recessed meter board 1.0 fabricated from G16steel sheet,powder coated lockable with all necessary accessories and adquate space for the following switchgear a. 315A TPN MCCB (Main incomer) b. 315A TPN 4 pole cu bus-bar item 1 c. 60A SPN MCB (High Rapturing Capacity) No. 21 d. KPL Single phase meters (space only) No. 21 e. KPL Single phase cutouts (space only) No. 21 f. Earth bar item 1 g. All internal cabling. Item 1 h Space for common service 8Way Consumer Unit Item 1 Earthing 2.0 Eathing point to comprise of the following, a. 15mm dia x 1500mm long copper earth electrode with connector clamp b. Driving head c. 25 mm sq copper earth lead No. Item d. Concrete Earth Manhole with cover No. Item e. Provisional Sum For Earthing improvement if necessary No. Item 3.0 Testing a. Testing of the whole installation to conform to No. item I.E.E Regulations 4.0 Supply and Lay in vertical riser 200 x 50 mm sheet steel cable tray with brackets at 1m intervals complete with cable cleats Lm 15 TOTAL FOR METERBOARD C/F TO COLLECTION PAGE Page 30 Page 27

28 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATIONS TV INSTALLATION DESCRIPTION UNIT QTY RATE TOTAL KSHS Supply,install, test & commission the following Way multiswitch as Televes Amps Power surge protection as Sollateck for the multiswitch 3.0 Aerial mast to carry the following high quality 2No. UHF reception aerials complete with mounting brackets and bolts. 4.0 DSTV Dish 5.0 Co-axial cable 100m rolls (Heavy duty) for 1No. Block of 20 No. apartments No Provide a rate for pulling and connection of cables from TV aerial/dstv Dish to multiswitch and to TV outlets at 20 No. flats Item Way splitter units No Allow for testing and commissioning of the installation No Item 9.0 Allow for any other items not covered in the bill to make the TV installation complete. No item 10.0 Supply and lay 200 x 50mm factory built cable tray complete with accessories LM 15 TOTAL FOR TV INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 30 Page 28

29 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATIONS LIGHTNING PROTECTION DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply,install, test and commission the following items : Suppy and Install a lightning protection 25 x 3mm copper tape as specified and indicated on the drawing Lm Suppy and Install a 15mm diameterx1800mm copper board earth rods as specified and indicated in the drawing 3.0 Copper lightning arrester(air termination),stem,and base on the roof,with the base fastened squarely on the ridge of the roof,inclusive of the base clamps and all fixing materials. 4.0 Supply and Install a block for 25 mm tape as specified and indicated in the drawings. No. 2 No. 2 No Roof conductor Support at 2m intervals No 11 Test Clamp as Furse Cross Coupler No Tape Clamping Brackets at 1m intervals No Copper plated steel grounding rods 2Mx14mm No Electrode ground connection No Testing and Commissioning item Price for any other item to complete the installation; list below item 1 TOTAL FOR 1No. BLOCK TOTAL FOR LIGHTNING PROTECTION INSTALLATION CARRIED FORWARD TO COLLECTION PAGE Page 30 Page 29

30 PROPOSED KISUMU HOUSING 1 BEDROOM TYPE 2 ELECTRICAL INSTALLATION WORKS COLLECTION PAGE DESCRIPTION TOTAL KSHS NO 1.00 Total B/F from page Total B/F from page Total B/F from page Total B/F from page Total B/F from page Total for 1 NO BLOCK of 20 Apartments x2 Nos Total for 2 NO BLOCK of 40 Apartments TOTAL CARRIED FORWARD TO SUMMARY PAGE Page 35 Page 30

31 PROPOSED KISUMU HOUSING EXTERNAL STREET LIGHTING, GATEHOUSES, & PUMP ROOMS DESCRIPTION UNIT QTY RATE TOTAL KSHS Supply and instal Light fitting complete with internal wiring, Lamps and control gear 1.0 Type P1 (mounted on 4.2m steel columns) No M street lighting pole made from class "B" steel galvanised pipe complete with a side entry including all necessary excavations and fixing to ground. No Photocell with mounting brackets No A SPN Contactor. No C/4 mm sq pvc/swa/pvc copper cable from the common service consumer unit at each block and terminating at the street lighting columns. M Cable glands, lugs and terminations for the above. Item 22 METERBOARD IN GATE HOUSE Fabricated from G16steel sheet,powder coated lockable with all necessary accessories and adquate space for the following switchgear a 60A SPN MCB (High Rapturing Capacity) b KPL Single phase meters (space only) c KPL Single phase cutouts (space only) d Earth bar item 1 e All internal cabling. Item 1 f Space for common service 6 Way Consumer Unit Item 1 Earthing 8.0 Eathing point to comprise of the following, a. 15mm dia x 1500mm long copper earth electrode with connector clamp b. Driving head c. 16 mm sq copper earth lead No. Item d. Concrete Earth Manhole with cover No. Item e. Provisional sum For Earthing improvement if necessary No. Item 9.0 Testing a. Testing of the whole installation to conform to No. item I.E.E Regulations c 16 mm.sq pvc swa pvc cu cable from Common Meterboard in Guard House 1 to the Splitter Units 2 No Substations and 2 No Gate Houses LM 370 TOTAL CARRIED FORWARD TO PAGE Page 32 Page 31

32 PROPOSED KISUMU HOUSING INSTALLATIONS FOR GATE HOUSES, SUB- STATIONS & PUMP CONTROL PILLAR BAL B/F 1.0 GATE HOUSE Supply and install the following: - Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way No Install light switches as MK or Crabtree a. 6A one gang one way b. 6A three gang one way 3.0 Light fitting complete with internal wiring and control gear only a. Type C No 1 b. Type 1 c. Type B No. 2 d. Type G No Final ring circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit a. 13A Twin switched socket outlet plates. No way SPN MCB recessed consumer unit incorporating No 1 60 A intergral isolator, lockable cover, labelling as MG a. Miniature circuit breaker b. 10 A single pole c. 20 A single pole d. 30A single pole. e. Blanking Plate No. 3 Cost for 1 GATE HOUSE X3 Nos. for 3 GATEHOUSES SUB-STATION INTERNAL INSTALLATION Supply and install the following: Final sub-circuit from Consumer Unit to lighting point comprising of 3 x 1.5mm sq sc copper cables drawin in 20mm diameter concealed conduit for one way 2.0 Install light switches as MK or Crabtree a. 6A two gang one way 3.0 Light fitting complete with internal wiring and control gear only a. Type 1 b. Type B No Final ring circuit from consumer unit to power outlet point comprising of 3 x 2.5mm sq sc copper cables drawn 20mm diameter Hg concealed conduit a. 13A Twin switched socket outlet plates. No way Splitter Unit, with 32A Integral Isolator No 1 a. Miniature circuit breaker b. 10 A single pole c. 30 A single pole Cost for 1 Substation X2 Nos. for 2 Substations TOTAL CARRIED FORWARD TO SUMMARY PAGE Page 35 Page 32

33 DESCRIPTION ( LAMP UNIT RATES ) UNIT QTY RATE TOTAL KSHS Supply and install only the following LAMPS FOR THE FITTINGS A 3 BEDROOM-TYPE 1 APARTMENT W HPF CFL bulbs- For type 1 fittings No W HPF CFL bulbs- For type W fittings W PL Energy saving lamp- For type C fittings No X18W T8 HPF Fluorescent mirror lamp- TYPE S 5.0 2X18W HPF Fluorescent batten lamp- TYPE 2 TOTAL TOTAL FOR 30 Nos. APARTMENT COMMON AREA W HPF CFL bulbs- For type B fittings No D 13W PL Energy saving lamp- For type 2D fittings No. 30 B 3 BEDROOM APARTMENT- TYPE W HPF CFL bulbs- For type 1 fittings No W HPF CFL bulbs- For type W fittings No W PL Energy saving lamp- For type C fittings No X18W T8 HPF Fluorescent mirror lamp- TYPE S No X18W HPF Fluorescent batten lamp- TYPE 2 TOTAL TOTAL FOR 40 Nos. APARTMENT C 2 BEDROOM APARTMENT W HPF CFL bulbs- For type 1 fittings No W HPF CFL bulbs- For type W fittings No W PL Energy saving lamp- For type C fittings No X 18W T8 HPF Fluorescent mirror lamp- TYPE S No X 18W HPF Fluorescent batten lamp- TYPE 2 TOTAL TOTAL FOR 120 Nos. APARTMENT COMMON AREA W HPF CFL bulbs- For type B fittings No D 13W PL Energy saving lamp- For type 2D fittings No. 96 TOTAL CARRIED FORWARD TO NEXT PAGE Page 26 Page 33

34 DESCRIPTION UNIT QTY RATE TOTAL KSHS E 1 BEDROOM APARTMENT-TYPE 2 SITE W HPF CFL bulbs- For type 1 fittings No W HPF CFL bulbs- For type W fittings No W PL Energy saving lamp- For type C fittings 4.0 1X18W T8 HPF Fluorescent mirror lamp- TYPE S 5.0 2X18W HPF Fluorescent batten lamp- TYPE 2 TOTAL TOTAL FOR 20 Nos. APARTMENT COMMON AREA W HPF CFL bulbs- For type B fittings D 13W PL Energy saving lamp- For type 2D fittings 0 F 1 BEDROOM APARTMENT-TYPE 2 SITE W HPF CFL bulbs- For type 1 fittings No W HPF CFL bulbs- For type W fittings No W PL Energy saving lamp- For type C fittings 4.0 1X18W T8 HPF Fluorescent mirror lamp- TYPE S 5.0 2X18W HPF Fluorescent batten lamp- TYPE 2 TOTAL TOTAL FOR 40 Nos. APARTMENT COMMON AREA W HPF CFL bulbs- For type B fittings D 13W PL Energy saving lamp- For type 2D fittings 0 Total For 1 No Block ( 20 units ) x2 For 2 Nos Blocks ( 40 No Units ) TOTAL N/B: Bidders to note that these rates shall also be compared and analyzed and form part of financial review for purpose of tender award recommendation. Page 34

35 PROPOSED KISUMU HOUSING MAIN PRICE SUMMARY-SITE 01 DESCRIPTION 1.00 Sub-Contract preliminaries TOTAL KSHS BEDROOM TYPE 1 APARTMENTS B/F FROM PAGE 7 2 & 3 BEDROOM TYPE 2 APARTMENTS B/F FROM PAGE 16 1 BEDROOM TYPE 2 APARTMENTS FOR SITE 1 B/F FROM PAGE 23 1 BEDROOM TYPE 2 APARTMENTS FOR SITE 2 B/F FROM PAGE EXTERNAL SERVICES B/F FROM PAGE SUB-TOTAL FOR ELECTRICAL INSTALLATION 8.00 CONTINGENCY 1,000, ATTENDANCE TO KPLC TOTAL CARRIED FORWARD TO MAIN SUMMARY PAGE TOTAL IN WORDS: KENYA SHILLINGS: ADDRESS: SIGNATURE: STAMP WITNESS'S NAME: SIGNATURE: DATE Page 35

TECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR

TECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR TECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR 1.0 GENERAL REQUIREMENTS The installation shall generally be carried out in conforming with the requirements of the Indian Electricity

More information

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST ANNEXURE I Sl.No. Description for BHEL Requirement Offered Deviation Scope of supply, erection and commissioning: 1 The scope of this specification covers

More information

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET

More information

BOQ FOR ELECTRICAL WORK OF HLST IN GROUND FLOOR AT S.B.I. LHO BHOPAL.

BOQ FOR ELECTRICAL WORK OF HLST IN GROUND FLOOR AT S.B.I. LHO BHOPAL. BOQ FOR ELECTRICAL WORK OF HLST IN GROUND FLOOR AT S.B.I. LHO BHOPAL. Note: Use of Flexible conduits & Elbows in Circuit wiring is not allowed except in exceptional site conditions with the approval of

More information

Electrical Service Guidelines

Electrical Service Guidelines Electrical Service Guidelines Middle Tennessee Electric Membership Corporation Revised: May 23, 2013 MTEMC's Electrical Guidelines TABLE OF CONTENTS Right-of-Way Clearance Guide 3 MTEMC Requirements 4

More information

A B Brown. This sheet forms part of *Inspection Report Number/*Certificate Number NA/ * EC/ * PIR *Delete as applicable DB1 60898

A B Brown. This sheet forms part of *Inspection Report Number/*Certificate Number NA/ * EC/ * PIR *Delete as applicable DB1 60898 NAPIT Electrical Test Continuation Sheet Requirements for Electrical Installations BS 767 [IEE Wiring Regulations] and for Please complete all the unshaded areas. This sheet forms part of *Inspection Report

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

Chapter 9. Bonding and Grounding

Chapter 9. Bonding and Grounding Chapter 9 Bonding and Grounding Objectives Describe why the cable should be bonded Describe bonding and grounding procedures Define Bonding and Grounding Explain Safety Benefits and intent of bonding and

More information

MAHARSHI DAYANAND UNIVERSITY ROHTAK (A State University established under Haryana Act No. 25 of 1975) NAAC accredited A Grade

MAHARSHI DAYANAND UNIVERSITY ROHTAK (A State University established under Haryana Act No. 25 of 1975) NAAC accredited A Grade MAHARSHI DAYANAND UNIVERSITY ROHTAK (A State University established under Haryana Act No. 25 of 1975) NAAC accredited A Grade NOTICE INVITING TENDER Sealed tenders on item basis are invited on behalf of

More information

E S T I M A T E TENDER FOR ELECTRICAL & DATA CABLING WORK FOR BANK OF INDIA, KALAWAD ROAD BRANCH(GROUND FLOOR)-RAJKOT CITY

E S T I M A T E TENDER FOR ELECTRICAL & DATA CABLING WORK FOR BANK OF INDIA, KALAWAD ROAD BRANCH(GROUND FLOOR)-RAJKOT CITY PART- IV - ELECTRIC WORK FOR BRANCH Supply, installation, testing and commissioning of following point wiring as per the specifications and drawings. The unit rate for the switch board and further to point

More information

800 Communications Circuits

800 Communications Circuits ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that

More information

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION February 2013 NOTE: If conflict exists between St. Thomas Energy s Conditions of Service and this document, the Conditions

More information

Decorative Metal Wiring Accessories in Assorted Plate Finishes

Decorative Metal Wiring Accessories in Assorted Plate Finishes Decorative Metal Wiring Accessories in Assorted Plate Finishes Switches Power Socket Outlets 13A Fused Connection Units Control Switches TV Telephone Data Sockets Deco unique product codes Decorative Metal

More information

Stylish Electrical Essentials

Stylish Electrical Essentials Stylish Electrical Essentials Switches Sockets Fused Connection Units Control Switches 45A Switch Plates Flex Outlet & Blank Plates Telephone and Data Outlets Coaxial and Satellite Outlets Cavity Wall

More information

GUIDE TO THE AM2 EXAM

GUIDE TO THE AM2 EXAM AM2 GUIDE TO THE AM2 EXAM What is AM2? AM2 or the Achievement Measurement 2 is a practical performance skill test administered by the National Electrotechnical Training (NET). You must take the AM2 test

More information

The complete guide to Low Voltage switchgear

The complete guide to Low Voltage switchgear The complete guide to Low Voltage switchgear The complete guide to low voltage switchgear Contents 4-7 Merlin Gerin LV Switchgear An introduction to the Merlin Gerin low voltage range of switchgear, and

More information

GENERAL ELECTRICAL REQUIREMENTS

GENERAL ELECTRICAL REQUIREMENTS GENERAL ELECTRICAL REQUIREMENTS RECEPTACLE SPACING Within 6-feet of the edge of any door HABITABLE Not more than 12-feet apart along wall ROOMS: At all wall spaces 24 or more wide Within 24 of edge of

More information

GUIDELINES FOR ELECTRICAL WIRING IN RESIDENTIAL BUILDINGS

GUIDELINES FOR ELECTRICAL WIRING IN RESIDENTIAL BUILDINGS GUIDELINES FOR ELECTRICAL WIRING IN RESIDENTIAL BUILDINGS 2008 EDITION www.st.gov.my CONTENTS Chapter Title Page 1. 1.1 1.2 1.3 Introduction Purpose References 4 4 5 2. Supply System 6 2.1 Electricity

More information

In the workshop. tool cabinet tool cupboard. drawer. armoire métallique metal locker. Double locker with two fixed shelves. Eight Drawer Tool Cabinet

In the workshop. tool cabinet tool cupboard. drawer. armoire métallique metal locker. Double locker with two fixed shelves. Eight Drawer Tool Cabinet In the workshop. tool cabinet tool cupboard drawer armoire métallique metal locker workbench Mobile Drawer Cabinet Double locker with two fixed shelves Eight Drawer Tool Cabinet Single Door Steel Tool

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

ELECTRICAL WORKS FOR CPCB ZONAL OFFICE AND LABORATORY AT BANGALORE. Consultants: SRIMATHA ENTERPRISES

ELECTRICAL WORKS FOR CPCB ZONAL OFFICE AND LABORATORY AT BANGALORE. Consultants: SRIMATHA ENTERPRISES Item No. BILL OF QUANTITIES WITH SPECIFICATIONS - ELECTRICALS Qty. Unit Rate Description 1.0 415VOLTS MAIN DISTRIBUTION BOARDS CONSTRUCTION (i) Sheet steel - 2mm thick for frames and equipment mounting

More information

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities DEHN + SÖHNE DEHNconductor System No Problems with Proximities DEHNconductor System - New Possibilities for controling Proximities. For preventing dangerous flashovers among parts of external lightning

More information

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT 1.1 General 1.1.1 These Special Conditions of Contract supplement the General Instructions.

More information

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision

More information

DIOCESE OF LINCOLN GUIDELINES

DIOCESE OF LINCOLN GUIDELINES DIOCESE OF LINCOLN GUIDELINES FOR ELECTRICAL INSTALLATIONS INSIDE CHURCHES Diocesan Advisory Committee for the Care of Churches Revised March 2006 Electrical Installations inside Churches As with all

More information

Schedule of Quantities

Schedule of Quantities CIVIL WORK (A) 1 Providing and fixing corrugated galvanised iron sheets of 20 B.W.G. for roofing with wind ties including fastening with galvanised iron screw and bolts and lead and bitumen washers as

More information

Electrical Code Regulation

Electrical Code Regulation Electrical Code Regulation St. Clair County has adopted the 2005 National Electrical Code in its entirety for the unincorporated areas of the county and all communities that have contracted with the county

More information

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures Meter Boxes SMB s To house a single phase kilowatt hour meter Standard kwh meter mounting Square or triangular securing screw Stand off for circuit breaker Optional circuit breaker reset rod DMB s To house

More information

6. BILLS OF QUANTITIES

6. BILLS OF QUANTITIES 6. BILLS OF QUANTITIES HOUSING BUILDINGS Item Unit Measu Number of General note: This BoQ shall include the delivery of materials stated under the individual items and all miscellaneous unspecified material

More information

1. Electrical Equipment A) Transformer

1. Electrical Equipment A) Transformer Standards and Basic Equipment Date : 15 November 2010 1. Electrical Equipment 2. Terminology 3. Code & Standard 1. Electrical Equipment A) Transformer A1) One Transformer and 11kV Switchgear in High Rise

More information

Hyperlinks are Inactive

Hyperlinks are Inactive Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)

More information

STATEMENT OF WORK Upgrade of Electrical Service and Primary Electrical Panel 208 Ratu Sukuna Road, Suva

STATEMENT OF WORK Upgrade of Electrical Service and Primary Electrical Panel 208 Ratu Sukuna Road, Suva STATEMENT OF WORK Upgrade of Electrical Service and Primary Electrical Panel 208 Ratu Sukuna Road, Suva INTRODUCTION: The United States Embassy in Suva, Fiji is seeking contractor proposals to upgrade

More information

www.klmtechgroup.com TABLE OF CONTENT

www.klmtechgroup.com TABLE OF CONTENT Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia ELECTIRAL GROUNDING TABLE OF CONTENT

More information

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264 BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used

More information

SATELLITE MASTER ANTENNA TELEVISION SYSTEM

SATELLITE MASTER ANTENNA TELEVISION SYSTEM SATELLITE MASTER ANTENNA TELEVISION SYSTEM The Contractor shall supply, install, test, commission, guarantee and maintain a Modern Satellite Master Antenna Television (SMATV) system for the distribution

More information

Electrical Practices for Construction Work

Electrical Practices for Construction Work 1. Purpose Electrical Practices for Construction Work The purpose of this Code is to provide practical guidance and set minimum safety requirements for electrical practices on all construction sites in

More information

LISTED BUILDING CONSENT APPLICATION HAMILTON HOUSE, 10 NORTH PARADE BUILDINGS. BATH. PROPOSED IRS SYSTEM, SATELLITE DISH & ANTENNA INSTALLATION.

LISTED BUILDING CONSENT APPLICATION HAMILTON HOUSE, 10 NORTH PARADE BUILDINGS. BATH. PROPOSED IRS SYSTEM, SATELLITE DISH & ANTENNA INSTALLATION. LISTED BUILDING CONSENT APPLICATION HAMILTON HOUSE, 10 NORTH PARADE BUILDINGS. BATH. PROPOSED IRS SYSTEM, SATELLITE DISH & ANTENNA INSTALLATION. DECEMBER 2011 JOB NUMBER 00168 REVISION B MARCH 2012 Contents:

More information

Consultants Handbook

Consultants Handbook Consultants Handbook CONSULTANTS HANDBOOK Welcome to our Wallis Designers Lightning Protection Handbook. This handbook offers a guide for any designers of the structural Lightning protection system to

More information

Circuit Electrical Testing

Circuit Electrical Testing Safe Isolation Procedure Circuit Electrical Testing Site Safety Management It is essential from the outset that effective management and control of the system, apparatus and equipment used on site is achieved

More information

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: Signed completed Electrical Permit application form. Minnesota law requires all electrical work is to be performed by licensed,

More information

Turnkey Projects, Conversions, Restorations & Property Management. Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE

Turnkey Projects, Conversions, Restorations & Property Management. Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE Turnkey Projects, Conversions, Restorations & Property Management Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE Reg. Office: Karlu Galea Street, Victoria, Gozo Malta. T. 2155 6600 M. 9943 4391

More information

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property. INTRODUCTION These rules are issued for use by Customers, builders, electrical contractors, architects, engineers, etc. The rules require the installation of safe and adequate wiring and electrical equipment,

More information

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

EARTHING AND BONDING AT SECONDARY SUBSTATIONS DISTRIBUTION CONSTRUCTION MANUAL SECTION 4 - SUBSTATIONS ISSUE B SEPT 1996 4.4.4 EARTHING AND BONDING AT SECONDARY SUBSTATIONS 1 SCOPE This section of the Distribution Construction Manual lays down the

More information

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad PLEASE MARK TICK ON LEFT BOX WHICH EQUIPMENT YOU HAVE QUOTED PROPOSAL BASED ON CHINESE EQUIPMENT

More information

SECTION 22 LIGHTNING PROTECTION SYSTEM

SECTION 22 LIGHTNING PROTECTION SYSTEM SECTION 22 LIGHTNING PROTECTION SYSTEM 22.01 SCOPE: A. These Specifications shall form a part of the Contract Documents and shall govern construction work for all buildings to be built or modified for

More information

know-how Giant in distributing electricity for industry Prisma GK

know-how Giant in distributing electricity for industry Prisma GK Prisma GK Giant know-how in distributing electricity for industry Installation system up to 630A for electrical power distribution and circuit control. Prisma GK: technology and innovation for an IP55

More information

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS GENERAL DESCRIPTION:

More information

CDGRD-10. Grounding. Solutions For Comm/Data Applications

CDGRD-10. Grounding. Solutions For Comm/Data Applications CDGRD-10 Grounding Solutions For Comm/Data Applications Overview & Table of Contents Cooper B-Line s Grounding products for rack & runway provide a complete solution for grounding metal supports. The offering

More information

No Phone Line II-48 System

No Phone Line II-48 System Used in conjunction with an EntraGuard Telephone Entry System, the -48 provides No Phone Line communication and door or gate control through existing building telephone lines without the need to purchase

More information

TENDER DOCUMENT FOR PROPOSED KIDNEY DIAYLSIS CENTRE AT THE 1ST STOREY OF BLOCK 128 BUKIT MERAH VIEW MECHANICAL & ELECTRICAL INSTALLATION WORKS

TENDER DOCUMENT FOR PROPOSED KIDNEY DIAYLSIS CENTRE AT THE 1ST STOREY OF BLOCK 128 BUKIT MERAH VIEW MECHANICAL & ELECTRICAL INSTALLATION WORKS TENDER DOCUMENT FOR PROPOSED KIDNEY DIAYLSIS CENTRE AT THE 1ST STOREY OF BLOCK 128 BUKIT MERAH VIEW MECHANICAL & ELECTRICAL INSTALLATION WORKS VOLUME 2 OF 2 CLIENT National Kidney Foundation 81 Kim Keat

More information

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132

More information

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE Toll Free Telephone Numbers Residential Services 800.454.3853 Commercial Services 800.653.5307 Utility Locating Company N.C. 800.632.4949 S.C. 888.721.7877

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

Regulations for the Installation of Electrical Wiring, Electrical Equipment and Air Conditioning Equipment

Regulations for the Installation of Electrical Wiring, Electrical Equipment and Air Conditioning Equipment Regulations for the Installation of Electrical Wiring, Electrical Equipment and Air Conditioning Equipment Qatar General Electricity & Water Corporation KAHRAMAA Customer Services Department State of Qatar

More information

About our Chairman cum- Managing Director

About our Chairman cum- Managing Director INTEGRATED GROUP Complete Range of Power Transmission and Distribution Equipments & Head office- SO 2-5, Second Floor, Amarjyoti Palace, Lokmat Square, Wardha Road, Nagpur-440012 Group E-mail ID : enquiry@integratedgroup.asia

More information

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 04, Issue 01 (January. 2014), V6 PP 01-12 www.iosrjen.org Paper on Basbar Trunking System for Electrical Supply to Industrial

More information

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1 Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader

More information

Electrical Safety Tips. Help us keep you safe

Electrical Safety Tips. Help us keep you safe Electrical Safety Tips Help us keep you safe To help you stay safe when using electricity, ActewAGL has compiled these electrical safety tips. For natural gas safety tips please see ActewAGL s natural

More information

GENERAL SPECIFICATION ELECTRICAL INSTALLATION

GENERAL SPECIFICATION ELECTRICAL INSTALLATION GENERAL SPECIFICATION FOR ELECTRICAL INSTALLATION IN GOVERNMENT BUILDINGS OF THE HONG KONG SPECIAL ADMINISTRATIVE REGION 2002 EDITION THE HONG KONG SPECIAL ADMINISTRATIVE REGION BUILDING SERVICES BRANCH

More information

Security Cameras, CATV, GPS & Satellite Protection. White Paper

Security Cameras, CATV, GPS & Satellite Protection. White Paper Security Cameras, CATV, GPS & Satellite Protection White Paper Security Cameras, CATV, GPS & Satellite Protection Surge Protection Solutions for PTC 1 Security Cameras, CATV, GPS & Satellite Protection

More information

African Development Bank Group

African Development Bank Group African Development Bank Group African Development Bank's Field Office in Abuja, Nigeria LOT 5: VOL 3 BILLS OF QUANTITIES: IT WORKS Prepared by Interstate Architects Ltd. In Conjunction with: IAA Associates

More information

NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION

NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION NCRMI/LIB/ELE001/15 4.09.2015 Competitive sealed quotations are invited

More information

Distribution Boards & Consumer Units

Distribution Boards & Consumer Units Distribution Boards & Consumer Units Enclosures for system pro M compact Distribution Boards & Consumer Units Contents General 2/ Distribution Boards Mini Center compact Mounting kits for compact accessories

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62305-3 Edition 2.0 2010-12 colour inside Protection against lightning Part 3: Physical damage to structures and life hazard INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE

More information

NATIONAL DIPLOMA IN ARCHITECTURAL TECHNOLOGY

NATIONAL DIPLOMA IN ARCHITECTURAL TECHNOLOGY PROGRAMME: COURSE NAME: NATIONAL DIPLOMA IN ARCHITECTURAL TECHNOLOGY SITE MANAGEMENT COURSE CODE: BLD 206 DURATION: 0 3 3 UNITS: 3 UNITS GOAL: GENERAL OBJECTIVES: On completion of this module the trainee

More information

Session 14 Cable Support Systems

Session 14 Cable Support Systems Session 14 Cable Support Systems Cable Support Systems in the IEC World A new IEC Standard, IEC61537 2001 has been developed If full details of the cabling layout are available then the likely cable load

More information

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS 13.1 13.2 2006 Edition SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS GENERAL

More information

Slimline Plus. Catalogue No. R6

Slimline Plus. Catalogue No. R6 Slimline Plus Catalogue No. R6 slimline plus Stylish Robust Ease of installation Affordable For over 55 years, MK Electric has been a household name throughout the Asia Pacific region, trusted and respected,

More information

REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING

REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING Revised October, 2013 TABLE OF CONTENTS 1.0 INTRODUCTION... 3 2.0 REQUIRED DRAWINGS... 3 2.1 Site Plan... 3

More information

MOBILE HOME SERVICE REQUIREMENTS GAS

MOBILE HOME SERVICE REQUIREMENTS GAS ELECTRIC AND GAS 1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 GENERAL 4.0 REFERENCE MATERIAL 5.0 TYPICAL UNDERGROUND UTILITY LAYOUT 6.0 METER PAD DETAILS 7.0 GENERAL INSTALLATION PROCEDURES 8.0 PEDESTAL SPECIFICATIONS

More information

Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125

Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC3-12 MC3-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated

More information

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications

More information

ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) Original Certificate DETAILS OF THE CLIENT Certificate reference: ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) Name: Address: PURPOSE

More information

Transformers from 25va to 500kva. Standard despatch in days not weeks

Transformers from 25va to 500kva. Standard despatch in days not weeks Transformers from 25va to 500kva Standard despatch in days not weeks JMS Transformers Ltd 20 Ivatt Way Westwood Business Park Peterborough PE3 7PG UK Tel: +44 (0)1733 760000 Fax +44 (0)1733 760004 e-mail:

More information

Specifications for Lightning Protection. ASAE Engineering Practice

Specifications for Lightning Protection. ASAE Engineering Practice Chapter 8: Lightning Specifications for Lightning Protection ASAE safety standards are not laws. They are recommended voluntary standards used by designers, engineers, manufacturers and users of the equipment,

More information

TECHNICAL SPECIFICATION FOR HIGH MAST LIGHTING SYSTEM, 20 MTRS HEIGHT

TECHNICAL SPECIFICATION FOR HIGH MAST LIGHTING SYSTEM, 20 MTRS HEIGHT TECHNICAL SPECIFICATION FOR HIGH MAST LIGHTING SYSTEM, 20 MTRS HEIGHT Annexure A Sl.No. Description 1 Scope: The scope cover the design, manufacturing, supply and delivery at GCF Jabalpur on FOR basis

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12 SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications

More information

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document

More information

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time Trial Exams C Standards and Regulations Examination No: GH-08-C- This test is intended to gauge your knowledge of essential information contained within AS/CA S009:2013. To qualify for an allpication to

More information

FEDERAL ELECTRICITY & WATER AUTHORITY

FEDERAL ELECTRICITY & WATER AUTHORITY UNITED ARAB EMIRATES FEDERAL ELECTRICITY & WATER AUTHORITY SPECIFICATION FOR 433 VOLTS SWITCHGEARS (LVAC BOARD) LVAC SWITCHBOARDS I N D E X CLAUSE TITLE 1. GENERAL 2. TEMPERATURE RISE 3. BUSBARS 4. CONSTRUCTION

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 05 14.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 05 14.00 10 (April 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

Electrical Grounding. Appendix C

Electrical Grounding. Appendix C Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

Financial Bid Format(All Inclusive)

Financial Bid Format(All Inclusive) Financial Bid Format(All Inclusive) Sl. N. Description In Figure Rate Per Unit In Words 1 ROUTER TYPE A 2 ISP LINK LOAD BALANCER 3 INTERNET SECURITY 4 ROUTER TYPE B 5 USER & DEVICE IDENTITY MANAGEMENT

More information

Building Services Engineering Technician

Building Services Engineering Technician Building Services Engineering Technician A competent Building Services Engineering Technician is expected to be able to demonstrate the following skills and competences: Systems design in the building

More information

SCOPE OF WORK - SUBSTATION

SCOPE OF WORK - SUBSTATION SCOPE OF WORK - SUBSTATION VI - i TABLE OF CONTENTS 4.2 SCOPE OF WORK - SUBSTATIONS... 1 4.2.1 General... 1 4.2.2 Standard Substation... 2 4.2.3 33 kv Switchgear GIS Type... 2 4.2.3.1 Transformer Bay...

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope 3. TYPES OF SERVICE AVAILABLE 3.1 Scope UI supplies 60 hertz, alternating current with different voltage and ampere ratings. Not all voltage and ampere ratings are available throughout the entire service

More information

6.0 Electrical Installations

6.0 Electrical Installations 6.0 An electrical installation is a combination of electrical equipment installed to fulfill a specific purpose and having coordinated characteristics. In dealing with the electrical installation, it is

More information

Please check with your local inspection authority for any additional requirements before installation.

Please check with your local inspection authority for any additional requirements before installation. Specifications for Residential Overhead Electric Service Installation This brochure addresses most typical residential overhead service installations. Variances for the following specifications must be

More information

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket

More information

Syphonic Roof Drainage

Syphonic Roof Drainage Page 1 T E C H N O L O G Y 2:39 pm Syphonic Roof Drainage P L U M B I N G 23/5/03 A D V A N C E D Prod & Price Gd.for PDF Product Guide SYPHONICS Advanced Roof Drainage Technology Geberit Syphonics Geberit

More information

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation Used in conjunction with EntraGuard Gold Telephone Entry Systems, the provides No Phone Line communication and door or gate control through existing building telephone lines without the need purchase phone

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS 1. Standards BOS Item / System I ii iii TECHNICAL SPECIFICATIONS Applicable BIS /Equivalent IEC Standards / Applicable MNRE Specifications Standard Description Standard Number Crystalline Silicon Terrestrial

More information

Spare Parts List Activ A 12OV Activ A 15OV Activ A 20OV Activ A 25OV

Spare Parts List Activ A 12OV Activ A 15OV Activ A 20OV Activ A 25OV *175620240* 17562.024.0 REV1 01/06 2010 Spare Parts List Activ A 12OV Issue Table description Issue n. of pages Overall view 1 Main circuit assembly 1 Gas assembly 1 Valves and connection pipes 1 Control

More information

SECTION 3.9 STANDARD SPECIFICATION FOR ELECTRICAL EQUIPMENT/SWITCHBOARDS FOR SUBMERSIBLE SEWERAGE PUMP STATIONS

SECTION 3.9 STANDARD SPECIFICATION FOR ELECTRICAL EQUIPMENT/SWITCHBOARDS FOR SUBMERSIBLE SEWERAGE PUMP STATIONS SECTION 3.9 STANDARD SPECIFICATION FOR ELECTRICAL EQUIPMENT/SWITCHBOARDS FOR SUBMERSIBLE SEWERAGE PUMP STATIONS 3.9.1 GENERAL 3.9.1.1 DESIGN RESPONSIBILITY 3.9.1.2 SITE CONDITIONS 3.9.1.3 SUPPLY AUTHORITY