1 1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking equipment Abandoned cable removal 2 1

2 10/14/2009 All cables have a label which shows: Manufacturer s name Number of conductors Gauge of the conductor The rating of the cable UL seal. Distance markers

3 10/14/

4 7 Twisted Pair Voice and Data CMP - Communications Plenum Used in plenum spaces Rated for fire resistance and low smoke characteristics CMR - Communications Riser Used in vertical runs in a shaft Rated for fire resistance Used in wood construction and ducted return ceilings CMG, CM - Communications General Purpose Used within conduit Rated for fire resistance to a lesser extent CMX - Communications Limited Use Used for residential applications Resistant to flame spread 8 4

5 UTP Unshielded Twisted Pair Cat3, Cat5, Cat6 Voice and Data Audio Video STP Shielded Twisted Pair Not used in US Voice and Data Audio Video 18/2, 16/2, 14/2 Solid or stranded conductor Audio speaker Security Access Control Coax CATV (Community Access Television) 9 10 Gig Cat5e Cat6 Cat5 Cat5E Cat3 10 5

6 Cat3 10 mbs data Telephone Cable Relatively inexpensive $.15 per foot Rarely used except by phone system installer 11 Cat5 10/100mbs data Telephone cable Building Systems, Fire Alarm, Security $.21 per foot Cat5e 10/100mbs data Telephone cable Building Systems, Fire Alarm, Security $.27 per foot Cat5E 10/100 data, gigabit speed in short run, small office networks Telephone cable Building Systems, Fire Alarm, Security $.34 per foot 12 6

7 Cat6 Commonly installed for both voice and data Gigabit data $.47 per foot Cat6A Latest and Greatest 10 gigabit over copper No electronics support 10 gig yet Testing parameters established $.99 per foot 13 Fiber can be run greater distances compared to copper. Fiber is immune to EMI Fiber provides higher bandwidth Fiber provides a more secure connection Expensive Single-mode Multimode 14 7

8 Single Mode Single ray of light Long haul fiber Greater bandwidth Very expensive Carries service to your building 15 Multimode Communications over shorter distance Within buildings or campus 10Gbit/s up to 600 meters Compare to 1 Gbit/s 90 meters Cat micron or 50 micron 6 Strand Common One strand send, one receive 16 8

9 RG59 Was used primarily for cable installations Currently used for closed circuit television RG6 Cable TV and Satellite Latest use for cable modems/internet RG11 Used for long drops Outside plant A outer plastic sheath B Copper Screen C Inner dielectric insulator D Copper Core 17 Security Cable Multiple conductors under single jacket Occasionally Cat5 is used Stranded and solid core conductor Usually has a foil shield to eliminate interference Jacket should be white for easy identification 18 9

10 Fire Alarm Multiple conductors under single jacket Primarily solid core conductor Usually has a foil shield to eliminate interference Jacket should be red for easy identification 19 Audio Overhead paging and music speakers Two to four conductors under a single jacket Stranded conductors In rare cases foil surrounds the conductors Do not use the clear jacketed wire. 12 gauge to 20 gauge 16 gauge will usually fill most needs 20 10

11 COAX 75 ohm Satellite and Cable to receiver box Composite (Good) Yellow RCA - single analog signal Does not carry audio S-Video (Better) Round Connector 4 pins Separates video into gray scale and color Does not carry audio Component (Mo Better) Three RCA cables separates reds, greens and blues Does not carry audio HDMI (Best) Digital HD connection Carries digital audio 21 Standards BICSI Building Industry Consulting Service International. EIA Electronic Industries Alliance TIA Telecommunications Industry Association NFPA National Fire Protection Association NEC National Electric Code 22 11

12 NEC 2005 Article Securing and Supporting (A) Secured in place Raceways, cable assemblies, boxes, cabinets, and fittings shall be securely fastened in place. Support wires that do not provide secure support shall not be permitted as the sole support. Support wires and associated fittings that provide secure support and that are installed in addition to the ceiling grid support wires shall be permitted as the sole support. Where independent support wires are used, they shall be secured at both ends. Cables and raceways shall not be supported by ceiling grids. (C) Cable wiring methods shall not be used as a means of support for other cables, raceways, or non-electrical equipment 23 NEC 2008 Article Access to Electrical Equipment Behind Panels Designed to Allow Access Access to electrical equipment shall not be denied by an accumulation of wires and cables that prevents removal of panels, including suspended ceiling panels

13 NEC 2008 Article Mechanical Execution of Work Communications circuits and equipment shall be installed in a neat and workmanlike manner. Cables installed exposed on the surface of ceilings and sidewalls shall be supported by the building structure in such a manner that the cable will not be damaged by normal building use. Such cables shall be secured by straps, staples, hangers or similar fittings designed and installed so as not to damage the cable. 25 Cable Hangers J-Hook Cable Saddle Cable Tray All cable should be supported every

14 Power Separation EMR Electromagnetic Interference Avoid crossing fluorescent lighting fixtures Avoid running near electric motors Do not run data cables parallel to electrical wiring Cross electrical wiring at 90 Maximum Distance Horizontal Channel patch cord to patch cord. Cable run Entrance Facility Vertical Backbone Pathways Riser Room Telecom Room MDF IDF Server Closet 28 14

15 Entrance Facility Telecommunications service enters into a building Backbone pathways linking to other buildings Contains public network devices Contains telecommunications equipment Dry Area Near vertical backbone pathways 29 Entrance Facility Fiber Connections 30 15

16 10/14/2009 Entrance Facility 900 pair splice Split into 25 pair cables Entrance Facility 25 pair cables Bonding Repeating Distribution 16

17 10/14/2009 Entrance Facility 25 pair cables Bonding Repeating 33 Entrance Facility MUX Multiplexer Combines multiple signals into single connection Connects to incoming fiber optic cable 34 17

18 10/14/2009 Vertical Backbone Pathway Riser Room Telecom Room Distribution point of telecommunications on a floor Should remain neat Label all cables passing through risers 35 Vertical Backbone Pathway Riser Room Telecom Room Usually one of the messiest rooms on the floor

19 Main Distribution Frame MDF Main computer room for servers, hubs, routers, etc Intermediate Distribution Frame IDF Remote closet connected to MDF by fiber or copper. Hubs Patch panels 37 Server Room Data Rack Server Cabinet Server Networking Equipment Patch Panel Router Hub Switch UPS 38 19

20 UPS Smart Jack Server Patch Panel Router Hub Switch UPS Smart Jack 66 block 39 Server Room Patch Panel - rear Provides the termination point of the work area outlet

21 10/14/2009 Server Room Patch Panel - front Provides a splice to connect work area outlet to hub 41 Server Room Traffic Control Hub Free flow of traffic Collisions Hampered movement Switch Some traffic control 4 way stop First come first server Router Complete control Stop light Direction is contoled 42 21

22 10/14/2009 Uninterruptible Power Supply UPS Provides continuous power to the networking equipment 43 Smart Jack Incoming T1 service 44 22

23 NEC 2002 Article 800 Communications Circuits Abandoned Cable Installed communications cable that is not terminated at both ends at a connector or other equipment and not identified for future use with a tag The accessible portion of abandoned communications cables shall not be permitted to remian 45 National Fire Protection Agency Fuel Load Toxic Gases Weight 46 23

24 Removal Techniques Exercise Caution - Building Systems HVAC Security Fire Alarm Floor Jacks Start from the wall plate Always cut dead ends below ceiling tile Call a professional 47 Brett Weiss Gabe Martinez Brian Kroeger

Network Design. Yiannos Mylonas

Network Design. Yiannos Mylonas Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which

More information

800 Communications Circuits

800 Communications Circuits ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that

More information

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other

More information

ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard.

ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard. WIRING STANDARD INTRODUCTION This standard defines a telecommunications wiring system for North Dakota State Agencies, offices or buildings that will support a multi-product environment. The purpose of

More information

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers Jonathan Jew jew@j-and-m.com J&M Consultants, Inc Co-chair TIA TR-42.1.1 data center working group Co-chair BICSI data centers standards

More information

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6 050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY

More information

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified Our Mission At Cablesys, our mission is to simplify

More information

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below: Washington University in St. Louis Building: Communication Specification: Research Voice/Network/Typical 1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

More information

AWG: Cat5e: Cat6: Cat6A:

AWG: Cat5e: Cat6: Cat6A: Some of the terms used in the cable business can be vexing to even the most seasoned folks in the industry. If any of this terminology has ever made you scratch your head, you are certainly not alone.

More information

Errata NFPA 70. Proposed 2014 Edition

Errata NFPA 70. Proposed 2014 Edition Errata NFPA 70 National Electrical Code (Report on Proposals) Reference: 12-109 (Log #1618) Panel Meeting Action Proposed 2014 Edition The National Electrical Code Technical Correlating Committee notes

More information

SECTION 25110 TELECOMMUNICATION ROOMS

SECTION 25110 TELECOMMUNICATION ROOMS PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication

More information

Security & Surveillance Cabling Systems

Security & Surveillance Cabling Systems Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.

More information

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit

More information

Colorado Army National Guard Grand Junction Readiness Center NGB PN 080204 Coover-Clark & Associates CCA Job No. 0726

Colorado Army National Guard Grand Junction Readiness Center NGB PN 080204 Coover-Clark & Associates CCA Job No. 0726 SECTION 260523 - CONTROL-VOLTAGE ELECTRICAL POWER CABLES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. UTP cabling. 2. RS-232 cabling. 3. RS-485 cabling. 4. Low-voltage control cabling. 5. Control-circuit

More information

ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers

ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers Jonathan Jew jew@j-and and-m.com J&M Consultants, Inc Co-chair TIA TR-42.1.1 data center committee Co-chair BICSI data centers

More information

1 Campus Cabling Systems Introduction

1 Campus Cabling Systems Introduction 1 Campus Cabling Systems Introduction This document represents the campus cable and infrastructure standards adopted and supported by the XXXX. All new construction and renovation should conform to these

More information

Chapter 4 Connecting to the Internet through an ISP

Chapter 4 Connecting to the Internet through an ISP Chapter 4 Connecting to the Internet through an ISP 1. According to Cisco what two things are essential to gaining access to the internet? a. ISPs are essential to gaining access to the Internet. b. No

More information

Specifying an IT Cabling System

Specifying an IT Cabling System Specifying an IT Cabling System This guide will help you produce a specification for an IT cabling system that meets your organisation s needs and gives you value for money. You will be able to give your

More information

Telecommunications Infrastructure Standard for Data Centers. 802.3 Tutorial

Telecommunications Infrastructure Standard for Data Centers. 802.3 Tutorial Telecommunications Infrastructure Standard for Data Centers 802.3 Tutorial Prepared by: Jonathan Jew - J&M Consultants and Chris DiMinico - MC Communications - Co-chairs TR42.1.1 TR42: Data Center Standard

More information

RF Video Distribution System. Why Z-Band is The Right Choice for Quality Video

RF Video Distribution System. Why Z-Band is The Right Choice for Quality Video RF Video Distribution System Why Z-Band is The Right Choice for Quality Video Requirements for Quality RF Video Correct Signal & Noise Levels from Source/s Correct Signal & Noise Levels from Backbone Cabling

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION 17650 SECURITY SYSTEMS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION 17650 SECURITY SYSTEMS PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Inspections and observations by the Owner do not relieve the A/E of contract responsibilities. B. Chain of command 1. The DPS Project Manager is

More information

SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING

SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 05 14.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 05 14.00 10 (April 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Specification SFTP CAT6 Network Cable 23AWG CU

Specification SFTP CAT6 Network Cable 23AWG CU Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)

More information

DEPARTMENTAL REGULATION

DEPARTMENTAL REGULATION U.S. DEPARTMENT OF AGRICULTURE WASHINGTON, D.C. 20250 DEPARTMENTAL REGULATION SUBJECT: Service Center Technology Modernization Project (SCTMP) Wiring/Cabling Specifications for Service Center Agencies

More information

TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. University of Chicago IT Services Infrastructure Services October 2011

TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. University of Chicago IT Services Infrastructure Services October 2011 TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS IT Services Infrastructure Services October 2011 Table of Contents 1 Introduction... 4 1.1 Planning and Design... 4 1.2.1 Roles and Responsibilities...

More information

Cabling and Building Infrastructure for Technology

Cabling and Building Infrastructure for Technology Cabling and Building Infrastructure for Technology by: Ernest J. Schirmer, Director Information Technology Infrastructure Design CUH2A Architecture Engineering Planning 211 Carnegie Center Princeton, NJ

More information

Telecommunications Systems Narrative Page 1 The Engineering Enterprise

Telecommunications Systems Narrative Page 1 The Engineering Enterprise I. TELECOMMUNICATIONS GENERAL REQUIREMENTS A. The project consists of a renovation to the historic Clinical Sciences building, originally built in 1933. The existing building has a total area of 105,000

More information

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute

More information

Security & Control Cables

Security & Control Cables Security & Control Cables Our multi-conductor cables are manufactured in a wide variety of gage sizes, shielding configurations and jacketing materials including plenum, riser and general purpose. Applications

More information

Installing a Physical Network. Chapter 8

Installing a Physical Network. Chapter 8 Installing a Physical Network Chapter 8 Contents Recognize and describe the function of basic components in a structured cabling system Explain the process of installing structured cable Install a network

More information

Implementing Fast Ethernet

Implementing Fast Ethernet Implementing Fast Ethernet R The Next Generation of Ethernet Fast Ethernet (also known as IEEE 802.3u or 100BASE-T) is quickly becoming the successor to Ethernet as the network topology of choice. Fast

More information

with Component Rating A Simple Perspective

with Component Rating A Simple Perspective Cat-6A UTP and Shielded with Component Rating A Simple Perspective Asef Baddar RCDD, DCD Sr. Technical Manager Leviton Middle East Category Specifications Agenda Terminology International & North America

More information

CCTV System Troubleshooting Guide

CCTV System Troubleshooting Guide Wouldn t be nice to start and finish a CCTV System Project without running into any problems before, during and after the installation is completed. Well, in this article we will try and explain why we

More information

SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND

SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND Belden Electronics Division P.O. Box 1980 Richmond, Indiana 47375-1980 2200 U.S. Highway 27 South Richmond, Indiana 47374-7279 Telephone: 765 983 5200 Facsimile: 765 983 5825 SUBJECT: NO MORE 300 VOLTS

More information

SaskTel pre-wiring guide and wire standards for Single Family Units (SFU)

SaskTel pre-wiring guide and wire standards for Single Family Units (SFU) SaskTel pre-wiring guide and wire standards for Single Family Units (SFU) Last revised: 23072012 Table of Contents General information... 3 Purpose of Guide... 3 Disclaimer... 3 Description of Pre-wiring...

More information

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE

More information

Specifications for Communication Cabling Distribution Systems

Specifications for Communication Cabling Distribution Systems Washington University in St. Louis Specifications for Communication Cabling Distribution Systems General Overview Listed below are the separate sub-systems of Washington University s structured cabling

More information

Copper Cabling Infrastructure Offering

Copper Cabling Infrastructure Offering Copper Cabling Infrastructure Offering High-Speed Copper Cabling Systems The deployment of high speed cabling systems has been increasing rapidly as data centers enable their physical infrastructure with

More information

Flexible and safe solutions, for decades. Cables for alarmand safety systems

Flexible and safe solutions, for decades. Cables for alarmand safety systems Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always

More information

Click here to see a video example of cable being burned outside the controlled lab environment. UL-910 Test for Flame-Propagation and Smoke Density

Click here to see a video example of cable being burned outside the controlled lab environment. UL-910 Test for Flame-Propagation and Smoke Density Plenum (CMP) Rated Cable Often found on building material lists, the Plenum rating (CMP) signifies cable that has passed stringent burn testing and is suitable for installation into Air Plenum spaces.

More information

TCTC Cabling Specifications

TCTC Cabling Specifications TCTC Cabling Specifications Purpose: To provide a standard specification that will be used for all Tri County Technical College (TCTC) facilities requiring structured cabling installation. Product specifications,

More information

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12 SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications

More information

SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete

More information

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications

More information

DESIGN GUIDELINES. Local Area Network

DESIGN GUIDELINES. Local Area Network DESIGN GUIDELINES Local Area Network The total oversight and management responsibilities for information assurance (IA) and protection of DoDEA s critical infrastructure fall under the purview of the DoDEA

More information

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications. Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment

More information

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 FITNESS FACILITY WIRING SPECIFICATIONS NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 CONTENTS: - Scope of work Summary - Equipment list - Technical specifications - Map of data

More information

Cabling and Connectors

Cabling and Connectors Cabling and Connectors General media considerations Broadband versus baseband Baseband transmissions use digital signaling and Time Division Multiplexing (TDM) Broadband transmissions use analog and Frequency

More information

Victor Elementary School District. Technology Infrastructure Standards 02-26-03. Victor Elementary School District

Victor Elementary School District. Technology Infrastructure Standards 02-26-03. Victor Elementary School District 15579 Eighth Street Victorville, CA 92392 Phone 760. 245-1691 Fax 760.245-6245 www.vesd.net 02-26-03 TABLE OF CONTENTS Introduction 3 Overview of Standards 3 Equipment Specifications 4 Material Specifications

More information

Structured and Point to Point Network Cabling for Industrial Automation

Structured and Point to Point Network Cabling for Industrial Automation Structured and Point to Point Network Cabling for Industrial Automation Introduction Industrial automation systems are undergoing dramatic transformations that require businesses to adopt new strategies

More information

Structured Wiring Specifications ERAU Daytona Beach Campus (Dec 14 2011)

Structured Wiring Specifications ERAU Daytona Beach Campus (Dec 14 2011) Structured Wiring Specifications ERAU Daytona Beach Campus (Dec 14 2011) A. Objectives The Information Technology (IT) Department of Embry-Riddle Aeronautical University (ERAU) seeks to establish a standards-based

More information

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc jew@j-and-m.com

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc jew@j-and-m.com Data Center Standards Making Progress on Many Fronts Jonathan Jew J&M Consultants, Inc jew@j-and-m.com J&M Consultants - 2008 Speaker Jonathan Jew Co-chair TIA TR-42.1.1 Data Center working group ANSI/TIA-942

More information

UT Southwestern Medical Center Information Resources Cable Installation Standard

UT Southwestern Medical Center Information Resources Cable Installation Standard UT Southwestern Medical Center Information Resources Cable Installation Standard PART 1- GENERAL 1.01 SUMMARY A. Furnish and install wire, cable, devices, equipment, and accessories for a complete system

More information

2011 National Electrical Code

2011 National Electrical Code 2011 National Electrical Code Changes of Interest to Data/Comm Cabling Contractors, Users and Code Enforcement Officials The National Electrical Code is published by the National Fire Protection Association

More information

FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS

FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS Document ID: WP-07-01-ENG Original Issue Date: May 2007 Version: 1.0 FTE Cabling Best Practices 1 Table of Contents Introduction and Applicable Standards...3

More information

VIDEO SURVEILLANCE OVER UTP WHITE PAPER INTRODUCING VIPER VIDEO SURVEILLANCE

VIDEO SURVEILLANCE OVER UTP WHITE PAPER INTRODUCING VIPER VIDEO SURVEILLANCE VIDEO SURVEILLANCE OVER UTP WHITE PAPER INTRODUCING VIPER VIDEO SURVEILLANCE 1 C O N T E N T S Security Systems can be integrated into any IT Network The Network Manager s New Responsibility The Problem

More information

E-Rate Data Cabling RFP. Addendum 2 ISSUED BY: Alvord Unified School District Information Technology Department

E-Rate Data Cabling RFP. Addendum 2 ISSUED BY: Alvord Unified School District Information Technology Department ALVORD UNIFIED SCHOOL DISTRICT E-Rate Data Cabling RFP Addendum 2 ISSUED BY: Alvord Unified School District Information Technology Department The following are Addendums to the original RFP titled DataCablingRFP.pdf.

More information

21/03/2013 Center Cable, S.L Camino del Barranco,4-6 P.I. Las Arenas de Pinto 28320 Pinto (Madrid) Tlf.916926030 www.centercable.

21/03/2013 Center Cable, S.L Camino del Barranco,4-6 P.I. Las Arenas de Pinto 28320 Pinto (Madrid) Tlf.916926030 www.centercable. 1 Centercable, is a leader distributor and cable manufacturing company located in Spain. Centercable offers you a wide range of special cables, optical fiber solutions and tailor made solutions. 2 Our

More information

SECTION 17400 ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

SECTION 17400 ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section. SECTION 17400 ACCESS CONTROL SYSTEM CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section. PART 1 - GENERAL 1.1 RELATED WORK A. 16060 Grounding and Bonding B. 16070 Electrical

More information

TIA 569 Standards Update Pathways & Spaces. Ignacio Diaz, RCDD April 25, 2012

TIA 569 Standards Update Pathways & Spaces. Ignacio Diaz, RCDD April 25, 2012 TIA 569 Standards Update Pathways & Spaces Ignacio Diaz, RCDD April 25, 2012 The purpose of this Standard is to standardize specific pathway and space design and construction practices in support of telecommunications

More information

BRIDGEWATER COLLEGE HERITAGE HALL RENOVATIONS 12057.00

BRIDGEWATER COLLEGE HERITAGE HALL RENOVATIONS 12057.00 SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING PART 1 - GENERAL 1.1 OVERVIEW A. This section provides the necessary guidelines to install service entrance cables to buildings and information for the

More information

Structured Cabling Network Services & Equipment Inside/Outside Plant Design Trenching

Structured Cabling Network Services & Equipment Inside/Outside Plant Design Trenching Structured Cabling Network Services & Equipment Inside/Outside Plant Design Trenching 502 Buffalo Rd., Ft. Pierre, SD 57532 (605) 224-1111 or (800) 747-6427 www.windcircle.net sales@windcircle.net Computers

More information

SECTION California Polytechnic State University ITS Telecommunications PART 1 GENERAL 1.01 DESCRIPTION 1.02 QUALITY ASSURANCE

SECTION California Polytechnic State University ITS Telecommunications PART 1 GENERAL 1.01 DESCRIPTION 1.02 QUALITY ASSURANCE PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

21 st Century Campus Network Responsibility Matrix 5/26/10

21 st Century Campus Network Responsibility Matrix 5/26/10 Definitions: DoIT Standards This column details the minimal configuration, which DoIT has defined in order to provide a campus-wide standard level of service. Departments may request services, which exceeds

More information

10Gain XP CAT 6A cable. a better way to travel

10Gain XP CAT 6A cable. a better way to travel 10Gain XP CAT 6A cable a better way to travel 2 3 a better way to travel Ever since the 10GBase-T Ethernet protocol was introduced, network engineers have been concerned about the weak link of unshielded

More information

B. PART 1 - GENERAL of SECTION 271300 BACKBONE COMMUNICATIONS CABLING shall also apply to this section.

B. PART 1 - GENERAL of SECTION 271300 BACKBONE COMMUNICATIONS CABLING shall also apply to this section. SECTION 271500 - HORIZONTAL UTP CABLING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Standards and Guidelines for Telecommunications Wiring Design and Installation Montana State University-Bozeman

Standards and Guidelines for Telecommunications Wiring Design and Installation Montana State University-Bozeman Standards and Guidelines for Telecommunications Wiring Design and Installation Montana State University-Bozeman This document defines the standards used for voice and data wiring in buildings used by MSU

More information

Building Telecommunications Infrastructure Requirements

Building Telecommunications Infrastructure Requirements Building Telecommunications Infrastructure Requirements This page identifies specific requirements for the design of telecommunications infrastructure for buildings at Clemson University. (Revised October,

More information

Code Compliance for Spring Steel Fasteners Based on the 2005 NEC

Code Compliance for Spring Steel Fasteners Based on the 2005 NEC Code Compliance for Spring Steel Fasteners Based on the 2005 NEC B-Line has recognized the need for a reference source, detailing the National Electrical Code requirements for Spring Steel Fasteners. The

More information

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration Bill Charuk, SR Product Manager, Data Center Solutions Introduction With the advent of data centers in communication infrastructure, various

More information

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com 1080P Extender for HDMI over one CAT5 GTV-HDBT-CAT5 User Manual gefentv.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:

More information

270526-TC Grounding and Bonding for Telecommunications Systems

270526-TC Grounding and Bonding for Telecommunications Systems 270526-TC Grounding and Bonding for Telecommunications Systems Part 1 - General Related Documents The following related sections of the OT standards shall also be applicable to this section. OT Engineer

More information

Fibre Optics and Avid

Fibre Optics and Avid Fibre Optics and Avid Page 1 Fibre Optics and Avid Date: December 24 th 2007 Product: Avid Unity MediaNet Optical Fibre Channel connections, Avid Unity MediaNet Optical Ethernet connections, Avid Unity

More information

Products. Technology. Services. Delivered Globally. LOW-VOLTAGE CABLING SOLUTIONS

Products. Technology. Services. Delivered Globally. LOW-VOLTAGE CABLING SOLUTIONS Products. Technology. Services. Delivered Globally. LOW-VOLTAGE CABLING SOLUTIONS THE ANIXTER DIFFERENCE We understand your growing challenge of competing in today s business climate and your need to continuously

More information

SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines

SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines This document contains critical information regarding the installation of a certified SYSTIMAX SCS that meets or exceeds performance

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System July 28, 2003 We are pleased to provide the following joint statement by CII,

More information

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com DATA CENTER NETWORK INFRASTRUCTURE Cable and Connectivity for the Most Demanding Networks Customer-focused, technology-driven, quality-assured for an unparalleled RETURN ON infrastructure investment DATA

More information

Data and Voice Network Infrastructure

Data and Voice Network Infrastructure Data and Voice Network Infrastructure Denis Levesque Mike Milne Sponsored By Data and Voice Network Infrastructure Page 1 Copyright APPA 2015 Published by APPA: APPA is the association of choice serving

More information

Networks. The two main network types are: Peer networks

Networks. The two main network types are: Peer networks Networks Networking is all about sharing information and resources. Computers connected to a network can avail of many facilities not available to standalone computers: Share a printer or a plotter among

More information

Network Telecommunications Design Standards Last Updated June 2013. Youngstown State University

Network Telecommunications Design Standards Last Updated June 2013. Youngstown State University 1 Network Telecommunications & Security Youngstown State University One University Plaza Youngstown, OH 44555 Network Telecommunications Design Standards Last Updated June 2013 Youngstown State University

More information

What are the requirements for a Home Network?

What are the requirements for a Home Network? What are the requirements for a Home Network? Setting up a computer network in your home is not rocket science but it pays to think about what you want/need before you start buying equipment or drilling

More information

270526-TC Grounding and Bonding for Telecommunications Systems

270526-TC Grounding and Bonding for Telecommunications Systems 270526-TC Grounding and Bonding for Telecommunications Systems Part 1 - General 1.1 Work Included 1.2 Scope of Work A. Provide all labor, materials, tools and equipment required for the complete installation

More information

USB 2.0 RG Port USB m CAT 5e/6/7 Extender System. User Guide

USB 2.0 RG Port USB m CAT 5e/6/7 Extender System. User Guide USB 2.0 RG2304 4-Port USB 2.0 100m CAT 5e/6/7 Extender System User Guide Thank you for purchasing the USB 2.0 RG2304 Extender System. Please read this guide thoroughly. This document applies to Part Numbers:

More information

Cat7/Class F New Installation Concept New infrastructure. Handbook

Cat7/Class F New Installation Concept New infrastructure. Handbook Cat7/Class F New Installation Concept New infrastructure Handbook contents 1 Introduction 3 2 What is the Cat7/Class F installation concept 3 3 Distribution centre 3 3.1 Patch Modules 3 4 How to handle

More information

Wiring with this step-by-step guide, you can make telephone, Internet, video, and audio connections anywhere in the house

Wiring with this step-by-step guide, you can make telephone, Internet, video, and audio connections anywhere in the house Multimedia Wiring with this step-by-step guide, you can make telephone, Internet, video, and audio connections anywhere in the house BY BRIaN walo voice & DATA video AuDIO Because I m an electrician, the

More information

B. Cross-Connect: A facility enabling the termination of cable elements and their interconnection or cross-connection.

B. Cross-Connect: A facility enabling the termination of cable elements and their interconnection or cross-connection. DIVISION 16 ELECTRICAL Section 16740 Telephone System PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION 16715 TELECOMMUNICATIONS ACCEPTANCE TESTING

SECTION 16715 TELECOMMUNICATIONS ACCEPTANCE TESTING PART 1 - GENERAL 1.1 SECTION INCLUDES A. Testing Publications and Standards B. Inspection and testing procedures for copper and fiber optic cable, RF CATV / MATV systems, and the antenna systems. C. Documentation

More information

TIA-942 Data Centre Standards Overview WHITE PAPER

TIA-942 Data Centre Standards Overview WHITE PAPER TIA-942 Data Centre Standards Overview WHITE PAPER TIA-942 Data Centre Standards Overview For the past 20 years, cabling standards have been the cornerstone of ensuring proper design, installation, and

More information

Upon completing this chapter, you will be able to: Describe the primary types and uses of twisted-pair cables Describe the primary types and uses of

Upon completing this chapter, you will be able to: Describe the primary types and uses of twisted-pair cables Describe the primary types and uses of Upon completing this chapter, you will be able to: Describe the primary types and uses of twisted-pair cables Describe the primary types and uses of coaxial cables Describe the primary types and uses of

More information

Minimum Standards for Data/Voice Infrastructure in New Building Construction

Minimum Standards for Data/Voice Infrastructure in New Building Construction UNIVERSITY OF WATERLOO Minimum Standards for Data/Voice Infrastructure in New Building Construction 12/17/2012 Offices 1. Two Work Area Outlets (WAO) on opposite walls, each with 2 jacks 2. Each WAO shall

More information

Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council

Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council Date: 6/19/2013 Version: 1.0 Prepared by: Gregory Cotten Department of General Services District

More information

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Questions to Ask When Planning the Cabling Plant Planning a copper cabling plant to support 10Gbps transmission

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

LAN Installation Handbook

LAN Installation Handbook ] LAN Installation Handbook LAN Installation Handbook Central Information Management Unit Office of the Prime Minister Version 1.0 April 2003 Contents Section 1 Introduction...1 Section 2 LAN Installation...3

More information

Network Cabling Guide

Network Cabling Guide Network Cabling Guide Poor or incorrectly installed network cabling can cause numerous problems with your computer network. Whilst we recommend that you employ a network / cabling specialist to wire and

More information

Cable Installation Project

Cable Installation Project Cable Installation Project 1. Intent. It is the intent of the U.S. Court of Appeals to install Category 6 (CAT6) data cabling in the Robert F. Peckham Federal Building and United States Courthouse, 280

More information

Reliable, Consistent, Quality

Reliable, Consistent, Quality Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic

More information