The world's largest elearning website for analytical scientists
|
|
- Susan Cannon
- 8 years ago
- Views:
Transcription
1 The world's largest elearning website for analytical scientists CHROMacademy will help increase your knowledge, efficiency and productivity in the lab HPLC GC MS SPE IR BLS BIO
2 HPLC GC MS SPE IR BLS BIO A CHROMacademy Premier Membership provides you with complete access to all content including: 1000 s of elearning Topics HPLC / GC / Sample Prep / MS/ Infrared / Basic Lab Skills* / Biochromatography* / * coming in 2015 The Essential Guide Webcast & Tutorial Archive Over 70 training topics covered by industry experts HPLC & GC Troubleshooting and Virtual Lab Tools Become the lab expert with our HPLC and GC troubleshooters 24hr Chromatography Support Ask the Expert - our experts will answer your questions within 24 hours 6 New Video Training Courses Fundamentals of HPLC / GCMS / GC / LCMS Method Development - HPLC & GC Assessments Test your knowledge, certificates awarded upon completion User Forum Communicate with others interested in analytical science Application Notes & Articles The latest application notes & LCGC articles Lite members have access to less than 5% of our content... Premier members get so much more
3 HPLC GC MS SPE IR BLS BIO e-learning for analytical scientists HPLC GC MS SPE IR BLS BIO e-learning for analytical scientists Packed with practical information that will help improve your skills and productivity Used by over 35,000 chromatographers worldwide, CHROMacademy will help increase your knowledge, efficiency and productivity in the lab. With a vast library of high-quality animated and interactive e-learning topics, webcasts, tutorials and troubleshooting tools we can help you refresh your chromatography skills or learn something completely new. CHROMacademy is simply the best training tool for analytical scientists - see for yourself!
4 HPLC GC MS Sample Prep Infrared Basic Lab Skills* Biochromatography* * coming in 2015 Each channel is packed with e-learning modules, webcasts, tutorials and interactive tools
5 High Performance Liquid Chromatography Injection Valve Anatomyy It is necessary to divert the flow of mobile phase away from the sampling system (i.e. the syringe) when aspirating the sample and / or filling the sample loop prior to injection. This is achieved using the injection valve containing a Rotor Seal. The interface between the HPLC capillaries and the stator is known as the Stator Face... Isolation Seal Rotor Seal THE THEORY OF HPLC Introduction to HPLC Chromatographic Parameters Band Broadening Column chemistry Reverse phase (partition) chromatography Ion-Pair Chromatography Normal phase (absorption) chromatography Gradient HPLC Quantitative and Qualitative HPLC Fast HPLC HILIC Supercritical Fluid Chromatography Introduction to Ion Chromatography Stator Face Stator INSTRUMENTATION OF HPLC Mobile Phase Considerations HPLC Solvent Pumping Systems Autosamplers Detectors
6 Gas Chromatography THEORY AND INSTRUMENTATION OF GC Introduction to GC Chromatographic Parameters Band Broadening Gas Supply and Pressure Control Sampling Techniques Sample Introduction GC Columns GC Temperature Programming GC Detectors Supercritical Fluid Chromatography 1. Aims & Objectives 2. Introduction 3. Supercritical Fluids 4. Modes of Chromatography 5. SFC Applications 6. SFC Instrumentation 7. Packed & Capillary SFC 8. The Mobile Phase 9. Exhaust Gases 10. Organic Modifiers 11. Pumping Issues 12. SFC Columns 13. SFC Stationary Phases & Column Selection 14. Detection 15. Pressure Regulators 16. Advantages and Disadvantages of SFC
7 Mass Spectrometry FUNDAMENTAL LC-MS +M M Non-Volatile Analyte is Charged in Solution Nebulising Gas e+ e + e + e + e + e + + e e + e M + + M + M + Me M + M M e + e Corona Electrode Pin Introduction Electro Spray Ionization Theory Electro Spray Ionization Instrumentation Mass Analyzers Atmospheric Pressure Chemical Ionization (APCI) Atmospheric Pressure Photo Ionization (APPI) Solvents, Buffers and Additives Vacuum Systems Flow Rates and Flow Splitting Orbitrap Mass Analyzers FUNDAMENTAL GC-MS Introduction GC Considerations GC -MS Interfaces MS INTERPRETATION General Interpretation Strategies Fundamentals of MS Proteomics Research
8 Sample Preparation SOLID PHASE EXTRACTION Molecular Properties 1. Learning Aims & Objectives 2. Functional groups 3. Molecular Properties 4. Functional group interactions 5. Hydrophobic or Non-Polar Groups 6. Hydrophobic Interactions -Solubility 7. Hydrophobic Interactions -Sorbents 8. Polar Groups 9. Polar Interactions -Solubility 10. Polar Interactions -Sorbents 11. Ionic groups 12. Ionic groups -ph Ka pka Ionic strength 13. Ionic Interactions -Solubility Sorbents 14. Ionic Interactions -Chelating Groups 15. Chelating Groups 16. Chelating Interactions 17. Solubility 18. Sorbents 19. Protein Binding 20. Assessment SPE Overview SPE Mechanisms Method Development Primary Sample Preparation Techniques Liquid / Liquid Extraction Techniques Approaches to Automation for SPE
9 Infrared Spectroscopy Infrared Spectroscopy Introduction to IR Spectroscopy 1. Electromagnetic Spectrum 2. Electromagnetic Radiation 3. Infrared Regions 4. Molecular Vibrations 5. Calculation of Molecular Vibrations 6. Infrared Active Modes 7. Absorption Considerations 8. The IR Spectrum 9. Infrared Absorption Signals 10. Dispersive IR Instruments 11. FTIR Instruments 12. FTIR Operation 13. Sample Preparation 14. Attenuated Total Reflectance (ATR) 16. Applications of IR Spectroscopy 17. References 18. Assessment Infrared Spectral Interpretation 1. Infrared Spectral Quality 2. Orbital Hybridization 3. Interpretation Concepts 4. IR Frequencies 5. Alkanes 6. Alkenes 7. Alkynes 8. Aromatic Compounds...
10 Basic Lab Skills coming spring 2015 Balance Locationy The location of a balance is important to ensure accuracy when weighing. Manufacturers will have specifications regarding the correct location of a balance within the laboratory. Draughts Balances should be located in a draught free location. This includes draughts from doors, windows, air conditioning, passers-by, and other equipment. Draughts will result in fluctuations in the balance reading. Many analytical balances will have doors to shield the weighing plate from draughts... BASIC LAB SKILLS. Laboratory Safety. Errors. Volumetric Lab Equipment. Balances. Measuring ph. Titrations. UV-visible Spectroscopy 1. Bonding Theory for UV-visible Spectroscopy 2. The Electromagnetic Spectrum 3. Origin of UV-Visible Spectra 4. Transmittance and Absorbance 5. Selection Rules and Intensity 6. UV-visible Chromophores 7. UV-visible Absorption Maxima of Chromophores 8. UV-visible Definitions 9. UV-visible Instrumentation 10. Optical Arrangements of Spectrophotometers 11. UV-Visible Instrument Configuration 12. Key UV-Visible Instrument Parameters
11 Bio Pharmaceutical Analysis coming summer 2015 Protein biopharmaceuticals such as monoclonal antibodies and recombinant proteins are currently in widespread use for treatment of various life-threatening diseases including cancer, autoimmune diseases, diabetes, anemia, etc. Protein therapeutics have a complexity far exceeding that of small molecule drugs, hence, unraveling this complexity represents an analytical challenge... BIO PHARMACEUTICAL ANALYSIS. Introduction 1. Global Pharmaceutical Market Overview 2. Basics of Protein BioChemistry Amino Acids 3. Basics of Protein BioChemistry Proteins 4. Monoclonal Antibiodies (mab) in Bipharmaceuticals 5. Monoclonal Antibiodies Form and Function 6. Protein Development and Manufacture 7. Biopharmaceuticals Advances in Efficacy and Safety 8. Trastuzumab a model monoclonal antibody (mab) 9. Trastuzumab production and characteristics 10. Trastuzumab common post translational modifications 11. Common mab Post Translation Modifications (PTM s) 12. Analytical Characterisation at the Protein Level 13. Reversed Phase HPLC Analysis of Intact and Reduced Proteins 14. Chromatographic Requirements 15. Chemical Derivatisation
12 Video Training Courses Watch, listen and learn with our new video courses. Each course contains 4 video training sessions, released over 4 weeks, with full tutor support and certification. Fundamentals of HPLC (Dr. Dawn Watson) Fundamentals of GCMS (Tony Taylor) Fundamentals of GC (Tony Taylor & Amy Claydon) Fundamentals of LCMS (Tony Taylor & Amy Claydon) HPLC Method Development (Tony Taylor) GC Method Development (Tony Taylor)
13 Member Overview Top Job Functions Analyst Chemist Lab Manager Mfg/Processing Purchasing QA/QC R&D Teaching Technical Services Toxicology Education PHD: 39% BA/BS/BSC: 56% Years of Experience 10+: 45% 6-10: 25% 1-5: 30%
14 Interactive Learning powered by CHROMacademy contains a vast library of high-quality animated and interactive e-learning topics
15 Search for things s of elearning topics, articles and applications Fix things... interactive tools for chromatographers We developed our Troubleshooters with busy chromatographers in mind. In 3 simple steps you overcome your instrument, separation and quantitation issues. GC Troubleshooter HPLC Troubleshooter
16 HPLC Troubleshooter Select up to 3 Chromatographic Symptoms Positive baseline drift Negative baseline drift Irregular baseline drift Cycling Baseline (Short Term) Cycling Baseline (Long Term) Erratic baseline Regular baseline noise Irregular baseline noise Baseline Spikes Not the Chromatogram I was expecting! a Loss of resolution (some peaks) Loss of resolution (all peaks) No Peaks Additional peaks (ghost peaks) Negative peaks (One or more peaks) Peak broadening (Loss of Efficiency) Normal Peak fronting (one or more peaks) Peak shouldering (one or more peaks) Peak splitting (one or more peaks) Peak tailing (one or more peaks) Rounded peaks Problem Change in selectivity Decreasing retention times Increasing retention times Too much retention 6 Select up to 2 Instrument Symptoms a Low pressure High pressure Continuously decreasing pressure (no sample injection) Continuously decreasing pressure (after sample injection) Continuously increasing pressure (no sample injection) Continuously increasing pressure (after sample injection) Pressure fluctuation Leaks in the solvent reserviour connective tubing Leaks at the degasser / fittings Leaks around the pump head Leaks around the check valves or fittings Leaks in the autosampler or connective tubing Leaks around the sampling valve Leaks at the column fittings Leaks from the detector fiitings Leaks within the detector Poor quantititive reproducibility Poor linearity of response Possible Causes 1. Incorrect / non-optimal mobile phase ph 2. Incorrect column geometry / dimensions 3. Buffer precipitation 4. Incorrect buffer / non-optimal buffer concentration 5. Analyte-stationary phase secondary interaction (e.g. silanol interactions) 6. Incorrect mobile phase 7. Incorrect mobile phase temperature 6more Solution Mobile phase ph affects retention of ionisable analytes and the selectivity of separations in reversed phase HPLC Some methods require a very precise ph in order to remain robust Low ph tends to increase retention of acidic analytes and decrease retention of basic analytes 6more Resources Buffers and ph Meter This video explains how to prepare a buffer and use a ph meter. Buffer preparation This useful tool will help you to prepare the correct buffer for your HPLC analysis How to calibrate ph meter This video describes how to calibrate your ph meter 6more
17 HPLC GC SPE LCMS SPE HPLC GC MS IR BLS BIO Ask The Expert Can t find the answer to your question? Ask our panel of experts with a combined experience of over 100 years in chromatography. 24 hours is all we need to answer your question. Most often, we ll get something to you before then. Complex scenarios welcome! Problem solved!
18 Socialize powered by The Forum is your meeting place to learn and communicate with others interested in analytical science
19 powered by Monthly Activities Webcasts Live webcasts featuring industry experts, LCGC editors and CHROMacademy technical staff - archive available 24/7 Tutorials Comprehensive study guides with interactive content that dives deeper into the coresponding webcast Featured Content New content focusing on a technique or instrument Newsletter Tips, tricks and practical no nonsense solutions from chromatography experts each month Daily News RSS feeds from around the world Application Notes Thousands of application notes from instrument vendors
20 The Monthly Essential Guides. Each topic is covered with a 1hr webcast and comprehensive tutorial.
21 CHROMacademy newsletter Tips, tricks and practical no nonsense solutions from chromatography experts each month
22 Certified courses with tutor support. HPLC Operator Course HPLC Method Developer Course GC Operator Course GC Method Developer Course Each course covers all the key topics and is created by our experts in analytical chemistry. You can take a course at your own pace without a tutor if you wish, or you can opt in to have full tutor support and agree a timescale to complete the course on.
23 Reporting Tools. powered by With a multi user account you can set learning goals & track user progress
24 Saving Time & Money powered by Scientist A needed to understand why her chromatogram contained baseline spikes combined with a loss of sensitivity. She turns to CHROMacademy s HPLC Troubleshooter and in 2.3 seconds, CHROMacademy tells her there are 26 possible causes for this combination of symptoms. Each possible cause is ranked using our unique expert system and includes a comprehensive explanation and suggested fixes backed by 100 s of resources from LCGC magazine, CHROMacademy and instrument vendors. Without a CHROMacademy Premier Membership: Called her manufactures representative. 36 hours before someone called back Lost time of instrument use: 40 hours Lost $ = $2,000 (@$95K/annum) Contacted her Lab Manager 2 hours lost before Lab Manager could be located
25 Saving Time & Money powered by Scientist B needed to develop a sensitive GC-MS method for a chlorinated pesticide derivative present in potable water samples at very low levels. The derivative was new and therefore no applications existed in manufacturers literature. Using a CHROMacademy Webcast and Tutorial he was able to develop a GC method from a generic screening method and realized that Chemical Ionization was the route to attain the required sensitivity. From the Sample Preparation Channel he noted that solid phase extraction could be used to selectively extract the target analyte and again was able to develop a method from a suggested generic starting procedure. He used the ask the expert function to enquire of the CHROMacademy academic team how to create a sensitive MS acquisition method whilst checking for the presence of co-eluting interferences. Method was developed and was ready for validation within 1 week. Without a CHROMacademy Premier Membership: He wished that the department GC-MS expert hadn t been laid off.. Method development now begins using guesstimates
26 Benefits of a Group Premier Membership» Multiple Use $ Discount» Decrease in Travel Time and Money Used For Vendor Training» Satisfies Legislative and/or Regulatory Requirements for Training Within Your Industry and Laboratory» Easily Bolts on to Existing Learning Management System (SCORM Compliant)» Access to the Web s Largest Repository of Theory and Practical Information in Chromatography & Mass Spec.» Produces Common Lexicon» Learning Manager s Reporting Tools» Offers Centralized Billing» Recognized Leader in LCGC Magazine For Quick Buy-In From Staff» and Other Messaging to Reinforce Staff Engagement» Assessments and Tutorials With Printable Completion Certificates For Compliance» Trusted Vendor» Completely Web-Based (No IT Involvement Needed)» Certification Programs 2-5 Premier Membership $ Group Membership Available. Please contact your representative
27 Options Available Microsite Your Landing Page Completely build from top to bottom your very own learning site powered by CHROMacademy Your Logo and 1-2 Channels Customized Assessments Based on content agreed upon Certificate of Completion Certification Programs Offers your learners a goal to strive towards LMS - Connect Engagement Package Our Learning Management System is S.C.O.R.M. compliant and will connect to your system E-newsletter program derived from your content and ours Video Training Courses Live at Your Place Watch, listen and learn with our new video courses. Live in-person training including take home courseware, testing and certificates
28 Premier Membership Sales Single user - $ l l Group discounts available Contact sales@support.chromacademy.com Request a quote: Click here for our website submission form Alternatively you can contact our sales team directly USA & Rest of the World Sales Glen Murry phone: gmurry@advanstar.com United Kingdom Sales Crawford Scientific phone: +44 (0) enquiries@crawfordscientific.com Advertising/Sponsorship Mike Tessalone phone mtessalone@advanstar.com Technical Solutions sales@support.chromacademy.com
consultancy services
consultancy services Method Troubleshooting / Method Improvement (On-site or at our UK Laboratories) Problematic & poorly performing analytical methods have a high cost in terms of wasted analysis time
More informationTraining Courses 2014 HPLC GC SPE
Training Courses 2014 HPLC GC SPE 2 1 3 5 4 6 7 5 10 15 20 min 8 2 Courses & Presenters HPLC How to Run HPLC Methods Price: 249 + VAT Code: SS0-5943 Page: 4 How to Develop HPLC Methods Price: 249 + VAT
More informationChemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample
More informationThe Theory of HPLC. Gradient HPLC
The Theory of HPLC Gradient HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual. Aims
More informationGuide to Reverse Phase SpinColumns Chromatography for Sample Prep
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10
More informationLC-MS/MS for Chromatographers
LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS, with an emphasis on the analysis of drugs in biological matrices LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS,
More informationApplication Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software
Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software Abstract Presented here is a case study of a walk-up liquid chromatography
More informationSplit / Splitless Injection for Capillary GC
Split / Splitless Injection for Capillary GC Speakers John V Hinshaw CHROMacademy GC Dean GC Connections editor Moderator Tony Taylor CHROMacademy Trainer Technical Director, Crawford Scientific Dave Walsh
More informationAppendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
More informationBackground Information
1 Gas Chromatography/Mass Spectroscopy (GC/MS/MS) Background Information Instructions for the Operation of the Varian CP-3800 Gas Chromatograph/ Varian Saturn 2200 GC/MS/MS See the Cary Eclipse Software
More informationThe Essential CHROMacademy Guide. Mobile Phase Optimization Strategies for Reversed Phase HPLC
The Essential CHROMacademy Guide Mobile Phase Optimization Strategies for Reversed Phase HPLC Webcast Notes Type your questions in the Submit Question box, located below the slide window You can enlarge
More informationHPLC Basics, Equipment, and Troubleshooting
HPLC Basics, Equipment, and Troubleshooting HPLC Basics, Equipment, and Troubleshooting explains chromatography in practical terms from the ground up HPLC Basics, Equipment, and Troubleshooting HPLC Basics,
More informationDaniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz
Toxichem Krimtech 211;78(Special Issue):324 Online extraction LC-MS n method for the detection of drugs in urine, serum and heparinized plasma Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische
More informationOverview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
More informationHow To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
More informationWaters Core Chromatography Training (2 Days)
2015 Page 2 Waters Core Chromatography Training (2 Days) The learning objective of this two day course is to teach the user core chromatography, system and software fundamentals in an outcomes based approach.
More informationInfrared Spectroscopy 紅 外 線 光 譜 儀
Infrared Spectroscopy 紅 外 線 光 譜 儀 Introduction Spectroscopy is an analytical technique which helps determine structure. It destroys little or no sample (nondestructive method). The amount of light absorbed
More informationWaters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
More informationA High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS
A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS AB SCIEX QTRAP 4500 LC/MS/MS System and Gerstel, Inc. MultiPurpose Sampler
More informationANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION
Chem 306 Section (Circle) M Tu W Th Name Partners Date ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION Materials: prepared acetylsalicylic acid (aspirin), stockroom samples
More informationNUVISAN Pharma Services
NUVISAN Pharma Services CESI MS Now available! 1st CRO in Europe! At the highest levels of quality. LABORATORY SERVICES Equipment update STATE OF THE ART AT NUVISAN CESI MS Now available! 1st CRO in Europe!
More informationVCE CHEMISTRY 2008 2011: UNIT 3 SAMPLE COURSE OUTLINE
VCE CHEMISTRY 2008 2011: UNIT 3 SAMPLE COURSE OUTLINE This sample course outline represents one possible teaching and learning sequence for Unit 3. 1 2 calculations including amount of solids, liquids
More informationStrategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.
Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM Technical Overview Introduction The 5975A and B series mass selective detectors (MSDs) provide
More informationGENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1
GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert, Michel Lhermitte, Frederic Grisel Laboratoire de Toxicologie & Génopathologie, CHRU Lille, France Waters Corporation, Guyancourt,
More informationOverview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System
Investigating the use of the AB SCIEX TripleTOF 4600 LC/MS/MS System for High Throughput Screening of Synthetic Cannabinoids/Metabolites in Human Urine AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS
More informationLecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder
Lecture Chromo-3: Gas Chromatography CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Outline Introduction Instrument overview Carrier gas Sample
More informationHRMS in Clinical Research: from Targeted Quantification to Metabolomics
A sponsored whitepaper. HRMS in Clinical Research: from Targeted Quantification to Metabolomics By: Bertrand Rochat Ph. D., Research Project Leader, Faculté de Biologie et de Médecine of the Centre Hospitalier
More informationAdvantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites
Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites Carmen T. Santasania and David S. Bell SUPELCO, 595 North Harrison Road, Bellefonte, PA 16823 T404045 GUS Abstract
More informationSelectivity and Detectability Optimizations in HPLC
Selectivity and Detectability Optimizations in HPLC SATINDER AHUJA Development Department Pharmaceuticals Division CIBA-GEIGY Corporation Suflern, New York WILEY A WILEY-INTERSCIENCE PUBLICATION JOHN WILEY
More informationThermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs
Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex
More informationAMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
More informationAutomation of Solid Phase Extraction and Column Chromatographic Cleanup
Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for
More informationThermo Scientific HyperSep Solid Phase Extraction Method Development Guide
chromatography Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide The following guide provides considerations, tips and general guidelines for developing SPE methods using the Thermo
More informationLC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,
More informationHigh-Throughput 3-D Chromatography Through Ion Exchange SPE
High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample
More information# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water
Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system
More informationSymmetric Stretch: allows molecule to move through space
BACKGROUND INFORMATION Infrared Spectroscopy Before introducing the subject of IR spectroscopy, we must first review some aspects of the electromagnetic spectrum. The electromagnetic spectrum is composed
More informationPurification of reaction mixtures using flash chromatography.
Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?
More informationUsing Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract
Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate
More informationSIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC
SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC Katja SÄRKKÄ, Kari ARINIEMI, Pirjo LILLSUNDE Laboratory of Substance Abuse, National Public Health Institute Manerheimintie,
More informationUltraviolet Spectroscopy
Ultraviolet Spectroscopy The wavelength of UV and visible light are substantially shorter than the wavelength of infrared radiation. The UV spectrum ranges from 100 to 400 nm. A UV-Vis spectrophotometer
More informationContents. List of Contributors XIII The structure of The HPLC-Expert" Preface XVII
V List of Contributors XIII The structure of The HPLC-Expert" Preface XVII XV 1 LC/MS Coupling 1 1.1 State of the Art in LC/MS 1 Oliver Schmitz 1.1.1 Introduction 1 1.1.2 Ionization Methods at Atmospheric
More informationStep-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry BY GHULAM A. SHABIR Introduction Methods Validation: Establishing documented evidence that provides a high
More informationHow To Use Gc-Ms
The CHROMacademy Essential Guide Understanding GC-MS Analysis Part 1 Speakers John Hinshaw GC Dept. Dean CHROMacademy Tony Taylor Technical Director Crawford Scientific Moderator M ( g ) e M ( g ) 2e Peter
More informationPesticide Analysis by Mass Spectrometry
Pesticide Analysis by Mass Spectrometry Purpose: The purpose of this assignment is to introduce concepts of mass spectrometry (MS) as they pertain to the qualitative and quantitative analysis of organochlorine
More informationAnalyzing Small Molecules by EI and GC-MS. July 2014
Analyzing Small Molecules by EI and GC-MS July 2014 Samples Appropriate for GC-MS Volatile and semi-volatile organic compounds Rule of thumb,
More informationAir Sampling for Gases and Vapors. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike License. Your use of this material constitutes acceptance of that license and the conditions of use of materials on this
More informationAxION edoor. Web-Based, Open-Access Mass Spectrometry Software
AxION edoor Web-Based, Open-Access Mass Spectrometry Software 2 AxION edoor is the open-access software solution for today s fast-paced laboratory. It is designed to operate and optimize the management
More information1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.
Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative
More informationElectrospray Ion Trap Mass Spectrometry. Introduction
Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic
More informationSTANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA 94305-5080
Training on the ZQ Open access MS Questions? Contact Dr. Allis Chien allis@stanford.edu 650-723-0710 0710 STANFORD UNIVERSITY MASS SPECTROMETRY STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD
More informationTips & Tricks GPC/SEC: Analysis and Calibration For Low Molar Mass Macromolecules
GPC/SEC: Analysis and Calibration For Low Molar Mass Macromolecules Daniela Held, Silvia Fugmann, and Peter Kilz, PSS Polymer Standards Service GmbH, Mainz, Germany. Macromolecules can range from several
More informationChapter 21 Principles of Chromatography and Mass Spectrometry Problems 1,2,3,4,8,9,11,13
Chapter 21 Principles of Chromatography and Mass Spectrometry Problems 1,2,3,4,8,9,11,13 21-1 What is Chromatography Process to separate and purify compounds in a mixture by passing them trough a material
More informationGC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE
ACTA CHROMATOGRAPHICA, NO. 13, 2003 GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE A. Pavlova and R. Ivanova Refining and Petrochemistry Institute, Analytical Department, Lukoil-Neftochim-Bourgas
More informationAmino Acid Analyzer L-8900
Amino Acid Analyzer L-8900 VWR - Hitachi Your Partner in Amino Acid Analysis Hitachi has manufactured more than 1800 Amino Acid Analysers for over 40 years. The new Amino Acid Analyser Model L-8900 is
More informationThe Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD
TN-100 The Fundamentals of Infrared Spectroscopy The Principles of Infrared Spectroscopy Joe Van Gompel, PhD Spectroscopy is the study of the interaction of electromagnetic radiation with matter. The electromagnetic
More informationUnit title: Chemical Laboratory Techniques
Unit title: Chemical Laboratory Techniques Unit code: H/601/0355 QCF level: 4 Credit value: 15 Aim This unit gives learners the opportunity to practise and become proficient in a range of practical skills
More informationA Novel Approach to Low Volume Sample Preparation
A Novel Approach to Low Volume Sample Preparation Tony Edge, Jon Bardsley, Ken Meadows, Luisa Pereira International Symposium on Chromatography Salzburg, Austria September 2014 1 The world leader in serving
More informationAgilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS
Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS AGILENT 6000 SERIES LC/MS SOLUTIONS UNRIVALED ACHIEVEMENT AT EVERY LEVEL The Agilent 6000 Series of LC/MS instruments
More informationUHPLC/MS: An Efficient Tool for Determination of Illicit Drugs
Application Note: 439 UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela UHPLC System MSQ Plus MS Detector Drugs
More informationEnhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference
Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference Abstract The advantages of mass spectrometry (MS) in combination with gas
More informationORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
More informationAPI 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined
API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation
More informationThermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis
Thermo Scientific SOLAµ SPE Plates Technical Guide Consistent excellence for bioanalysis SOLAµ - delivering reproducible low volume extractions. Everytime! Thermo Scientific SOLAµ plates are designed for
More informationExpectations for GC-MS Lab
Expectations for GC-MS Lab Since this is the first year for GC-MS to be used in Dr. Lamp s CHEM 322, the lab experiment is somewhat unstructured. As you move through the two weeks, I expect that you will
More informationINFRARED SPECTROSCOPY (IR)
INFRARED SPECTROSCOPY (IR) Theory and Interpretation of IR spectra ASSIGNED READINGS Introduction to technique 25 (p. 833-834 in lab textbook) Uses of the Infrared Spectrum (p. 847-853) Look over pages
More informationCONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in
More informationHow To Use An Acquity Qda Detector
Mass-Directed Isolation of a Synthetic Peptide Using the ACQUITY QDa Detector Jo-Ann M. Jablonski and Andrew J. Aubin Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The ACQUITY QDa Detector
More informationOverview. Purpose. Methods. Results
A ovel Approach to Quantify Unbound Cisplatin, Carboplatin, and xaliplatin in Human Plasma Ultrafiltrate by Measuring Platinum-DDTC Complex Using LC/M/M Min Meng, Ryan Kuntz, Al Fontanet, and Patrick K.
More informationIntroduction to Fourier Transform Infrared Spectrometry
Introduction to Fourier Transform Infrared Spectrometry What is FT-IR? I N T R O D U C T I O N FT-IR stands for Fourier Transform InfraRed, the preferred method of infrared spectroscopy. In infrared spectroscopy,
More informationrefined marketing solutions
refined marketing solutions MEDIA PLANNER 2016 Serving the separations science research community for over a decade separationsnow.com was launched in 2002 and since has become an essential destination
More informationFast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan
Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract
More informationLC-MS/MS, the new reference method for mycotoxin analysis
LC-MS/MS, the new reference method for mycotoxin analysis What is necessary for the implementation of the multi-residue mycotoxin method in an analytical laboratory? Azel Swemmer azel@fdalab.co.za AFMA
More informationOasis HLB Cartridges and 96-Well Plates
CONTENTS I. INTRODUCTION II. SAMPLE PRE-TREATMENT a. Biological Samples b. Solid Samples: Soil, Whole Foods, Tissue c. Aqueous Samples: Water, Beverages d. Non-Aqueous Liquid III. SOLID PHASE EXTRACTION
More informationRequest for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# 600000-1621-RFQ)
Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) Closing Date and Time: Wednesday, April 13, 2016 at 5:00 p.m. (Pacific Time) Contact: Aaron Galloway Fax: 541-888-3250
More informationQ-TOF User s Booklet. Enter your username and password to login. After you login, the data acquisition program will automatically start.
Q-TOF User s Booklet Enter your username and password to login. After you login, the data acquisition program will automatically start. ~ 1 ~ This data acquisition window will come up after the program
More informationSCION SQ Series GC-MS
SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative
More informationIncreasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening
Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening Application Note Forensics Author Erin Shonsey Director of Research Alabama Department of Forensic Science Abstract
More informationMultiQuant Software 2.0 for Targeted Protein / Peptide Quantification
MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification Gold Standard for Quantitative Data Processing Because of the sensitivity, selectivity, speed and throughput at which MRM assays can
More informationQUANTITATIVE AMINO ACID ANALYSIS. Aurélie Lolia Applications Manager, Biochrom Ltd
QUANTITATIVE AMINO ACID ANALYSIS Aurélie Lolia Applications Manager, Biochrom Ltd QUANTITATIVE AMINO ACID ANALYSIS Principles of amino acid analysis Ion exchange chromatography The Biochrom 30 physiological
More informationReversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension
International Journal of PharmTech Research CODEN (USA): IJPRIF ISSN : 0974-4304 Vol.2, No.2, pp 1634-1638, April-June 2010 Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination
More informationChapter 28: High-Performance Liquid Chromatography (HPLC)
Chapter 28: High-Performance Liquid Chromatography (HPLC) Scope Instrumentation eluants, injectors, columns Modes of HPLC Partition chromatography Adsorption chromatography Ion chromatography Size exclusion
More informationAccurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances
Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances TripleTOF 5600 + LC/MS/MS System with MasterView Software Adrian M. Taylor AB Sciex Concord, Ontario (Canada) Overview
More informationQUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.
QUANTITATIVE INFRARED SPECTROSCOPY Objective: The objectives of this experiment are: (1) to learn proper sample handling procedures for acquiring infrared spectra. (2) to determine the percentage composition
More informationEKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS
EKSIGENT EKSPERT NANOLC 4 Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Focused ekspertise In 23, Eksigent changed the way scientists looked at nanoscale chromatography with the introduction
More informationCOURSE TITLE COURSE DESCRIPTION
COURSE TITLE COURSE DESCRIPTION CH-00X CHEMISTRY EXIT INTERVIEW All graduating students are required to meet with their department chairperson/program director to finalize requirements for degree completion.
More informationPerformance and advantages of qnmr measurements
Return to Web Version This is the first of a series of articles related to the launch of new organic CRMs certified by quantitative NMR under double accreditation. In this issue, we focus on CRMs intended
More informationDevelop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate
Cantaurus, Vol. 7, 5-8, May 1999 McPherson College Division of Science and Technology Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Janet Bowen ABSTRACT Sulfate is used in
More informationTherapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS
Therapeutic Drug Monitoring of Antiretroviral Drugs with PLC-M Ursula Gutteck-Amsler, Katharina M. Rentsch Abstract Prospective and retrospective studies have provided some evidence of the clinical and
More informationNMR and other Instrumental Techniques in Chemistry and the proposed National Curriculum.
NMR and other Instrumental Techniques in Chemistry and the proposed National Curriculum. Dr. John Jackowski Chair of Science, Head of Chemistry Scotch College Melbourne john.jackowski@scotch.vic.edu.au
More informationSTANDARD OPERATING PROCEDURES
PAGE: 1 of 33 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING, AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS
More informationSmartline HPLC by design
HPLC SMB Osmometry Smartline Systems Smartline HPLC by design Smartline high performance liquid chromatography instruments are designed to provide reliable separation solutions for routine tasks such as
More informationLIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: 1-13-93)
INTRODUCTION HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: 1-13-93) Headache, sore muscles, arthritis pain... How do you spell relief?
More informationA Complete Solution for Method Linearity in HPLC and UHPLC
Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,
More informationDETERMINACIÓN DE ESTRUCTURAS ORGÁNICAS (ORGANIC SPECTROSCOPY) IR SPECTROSCOPY
DETERMINACIÓN DE ESTRUCTURAS ORGÁNICAS (ORGANIC SPECTROSCOPY) IR SPECTROSCOPY Hermenegildo García Gómez Departamento de Química Instituto de Tecnología Química Universidad Politécnica de Valencia 46022
More informationMEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process
- Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples
More information