WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications



Similar documents
SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

CC-Link Ver.1.10 Compatible

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

LOW LOSS CABLE PAG. 1

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Coaxial Cables for Medium-Frequency Applications

EVOline Multimedia Modules

Cable Analysis and Fault Detection using the Bode 100

Communication, Signal & Data Cables

RX-AM4SF Receiver. Pin-out. Connections

Commercial Coaxial Cable

PL-277x Series SuperSpeed USB 3.0 SATA Bridge Controllers PCB Layout Guide

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Coaxial Cable Products Guide. Connectivity for Business-Critical Continuity

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

COAX Cables Radio Frequency Cables

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

Rack mounted telephone- and leased line modem for industrial applications

Nexus Technology Review -- Exhibit A

MANUAL HIPERFACE DSL. Implementation

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

75 Ω Transmission System

Specification SFTP CAT6 Network Cable 23AWG CU

This application note is written for a reader that is familiar with Ethernet hardware design.

Introduction to Digital Subscriber s Line (DSL)

Direct Attach Cable with Micro Coaxial Wire for Data Center

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

We hope that every customer sets up CC-Link system easily by reading this documentation.

STRUCTURED CABLING SYSTEMS

Standards Affecting a Premise T-1 Installation

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

6 ELECTRICAL PARAMETERS

Gigabit Ethernet on Copper Cabling Infrastructures

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

Grounding Demystified

Grounding and Shield Termination. Application Note 51204

M-Bus Network Installation Notes

X8 Option 2 - Technology

Telecommunication Line Protectors

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

Ultra640 SCSI Measured Data from Cables & Backplanes

Crosstalk effects of shielded twisted pairs

FlexPoint T1/E1 Copper to Fiber Line Driver

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

MICROCABLES. A complete vision of your connectivity needs. Catalogue

Understanding Shielded Cable

Managing Connector and Cable Assembly Performance for USB SuperSpeed

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

Frequently Asked Questions

RS485 & RS422 Basics

RS-422 and RS-485 Application Note

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

G019.A (4/99) UNDERSTANDING COMMON MODE NOISE

EMI in Electric Vehicles

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Broadband access. Nils Holte, NTNU. NTNU Department of Telecommunications Kursdagene ved NTNU, Digitale telenett, 9. januar

SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

EECC694 - Shaaban. Transmission Channel

Orion2+ SHDSL.bis Solution with 11Mbit/s and 15Mbit/s per Copper Pair

Interfacing Intel 8255x Fast Ethernet Controllers without Magnetics. Application Note (AP-438)

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

Understanding the Electrical Performance of Category Cables

Consideration of a high-capacity foil cable:

Eatman Associates 2014 Rockwall TX rev. October 1, Striplines and Microstrips (PCB Transmission Lines)

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

Long Range Ethernet Extender

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com

Documentation. M-Bus 130-mbx

38 Series - Relay interface modules A

ADACSNET USB Control Module

ROLINE THE Difference

The Do s and Don ts of Pressure Transducers

Fibre Optic Solutions for your Test and Instrumentation needs

Balanced vs. Unbalanced Audio Interconnections

How to Choose the Right Cable Category

PRODUCT SPECIFICATION

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

Uniprise Solutions COAX 101. White Paper.

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

2 Network Media. Copper Core Cable

Measurement setup for differential-mode and common-mode channels

Networks. The two main network types are: Peer networks

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable

STRANDED AND SOLID CONDUCTOR

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

with Component Rating A Simple Perspective

Transcription:

WHITEPAPER Cable and Connector for Hiperface dsl motor drive applications information for cable manufacturers Version 02

Content Information for cable manufacturers...3 Communication...3 Crosstalk & shielding...3 General electrical requirements...5 Recommendations for cable and connector design...7 Disclaimer...8 References...8 2 Whitepaper SICK 2013-12-12

Information for cable manufacturers The HIPERFACE DSL technology as a digital protocol offers a single cable connection between motor and drive controller. By reason of the protocol robustness it is possible to route the motor feedback wires within the motor energy cable. This simplifies the motor connection and saves costs.. The great advantage of a single cable connection creates some requirements for the communication at the same time when routing the communication wires within the same environment where also the power supply wires for the motor are located. In this case impacts from the power cables can create a signal disturbing crosstalk. Within this application note SICK Stegmann GmbH provides information and general recommendations for cable and connector design to achieve a stable and reliable HIPERFACE DSL connection. It is related to the signal lines only. The information provided inhere are subject to change based on ongoing tests and continuous improvements. The cable manufacturer is responsible for the overall motor cable design including the motor power supply and the requirements for different utilizations. Communication HIPERFACE DSL is a common digital interface based on RS485 transceivers with a transmission rate of 9,375 MBaud, based on a clock rate of 75 MHz. Cycle times down to 12,1 µs become possibly. With a cycle time of 192 µs save positions of the motor feedback system can be redundant transmitted. Suitable motor feedback systems could be used within SIL3-applications. For the communication interface high-speed RS485 transceivers are used. The data transmission is realized with differential signal from an inverted and non-inverted voltage level. Crosstalk & shielding Crosstalk means a noise signal coupling during exposure to EM interferences, finally caused by a changing electrical (to higher frequencies) and magnetic (to lower frequencies) field. Inductive crosstalk means, the cable operates like an AC- or pulse transformer from the energy wires to the DSL wires. Capacitive crosstalk is related to the distance between the wires as well as the dielectric properties of the material inbetween. (see also Fig. 1) The propagation of the noise signal happens in both directions forward & backward. The forward crosstalk of capacitive and inductive coupling has an opposite sign and is compensating up to a certain extent. [1], [2] 2013-12-12 Whitepaper SICK 3

This compensating effect can also be obtained at twisted pair wires. Based on the twist the wires have different positions within the field, which causes different signs of the coupled noise signal. This also leads to a certain compensation of the different noise contents. [2] Fig. 1 Cable model for capacitive and inductive crosstalk and signal propagation (forward and backward) [1] The coupling factor can be decreased by an increased wire distance and a decreasing dielectric thickness in-between. With this the line capacity to the shielding is increased what reduces the coupling into the neighborhood wire. [1] Finally proper wire insulation and shielding are the most important measures against crosstalk and communication signal disturbance. 4 Whitepaper SICK 2013-12-12

General electrical requirements With the numbers provided within this chapter information shall be given for basic requirements based on the current test and field experiences. The overall design target is a stable communication between encoder and drive controller via the signal lines. The residual signal margin as difference of transmission margin and line attenuation needs to be high enough for a reliable signal processing ( UDSL ±0,2 V). For suitable differential signal transmission both the communication lines shall be within equal environmental conditions. In reference to the previous chapter the overall goal of the cable design is the most possible reduction of crosstalk impacts from the motor power lines to the signal cable to reduce or avoid disturbances of the signal transmission. Based on the rated motor power and utilization (fix or moving) the required measures can be different. Not all individual and special application requirements can be foreseen. In this case additional tests and verifications of the numbers are recommended. Number of wires: 2 (for encoder supply & communication) Recomm. wire diameter: 0,34 mm² (e.g. AWG22); flex wires, copper typically 19 x 0,15 mm Style: shielded twisted pair Shielding: coverage >85 % type of shielding (braided and foil) based on the cable rated utilization Max poss. cable length: up to 100 m (for HIPERFACE-DSL) Based on today s knowledge recommendations for electrical performance are as followed: DC-line resistance: <100 /km (for each wire) Line impedance: 110 ±10 Propagation delay: 4,8 ns/m Velocity rate: >0,66 c Line attenuation: <5 db/100 m @ 10 MHz Test voltage: e.g. 600 V or 1000 V 2013-12-12 Whitepaper SICK 5

The numbers shown below are some references based on initial tests and field application experiences with running DSL-utilizations. These values are no design goal neither valid for all kinds of application. The purpose is to provide some basic information of currently running systems. Wire capacity. 60 nf/km @ 800 Hz (wire to shielding) Dielectricity number: <2,3 Wire inductance: Crosstalk attenuation: DC-shield resistance: DC-shield resistance: 0,9 mh/km >50 db (up to 100 MHz) <65 m /m (shielding motor cable) <150 m /m (shielding DSL cable) There is a wide range of different motor utilization conditions, which will require tailored cable designs to meet the requirements for the data communication as well as for the particular environmental conditions, defined also in various standards and guidelines. Throughout all different applications the most important issues are stable and reliable wire positions to each other within the cable, the quality of the shielding and the insulation material. 6 Whitepaper SICK 2013-12-12

Recommendations for cable and connector design Fig. 2 general configuration of a motor cable and principle location of the pins within a connector; a separate DSL- shield connection is required for coupling connectors within the line Fig. 2 shows the general structure of a 3 phase motor supply cable with an integrated DSL-lines and their separate shielding and Fig. 3 an example of a real hybrid cable. The proper and undamaged outer and DSL-shielding of the cable as well as its good contact at the connector is very important to avoid or reduce impacts of the power lines to the DSL-lines. Within the cable the location of the motor power wires shall be as far as possible away from the DSL-wires. Furthermore they shall be in a symmetric position to them. (see also Fig. 2/right) For stable and equal conditions along the whole length the DSL-line shall be done as shielded twisted pair wires. Depending on the rated application the shielding needs to withstand frequent cable bending within cable tracks at moving systems (robots or x-yhandling systems). Cable design and manufacturing shall be done in such a way, that the internal conditions (wire positions to each other or to the shielding or the coverage of the shielding) do not change over the time of utilization. Fig. 3 example of a real type hybrid cable with integrated motor brake and data wire (below, white/blue); left: specification drawing, right: real cable cut-off; source: Tecnikabel/Italy 2013-12-12 Whitepaper SICK 7

A symmetric arrangement shall be continued within the connector as well. A good electrical contact of the signal line shielding through the connector is very important. Multiple contacts for its connection can support this. The outer motor cable shielding and the signal wire shielding need to be separate from each other throughout the line between motor and drive controller. Based on tests and current experiences for the connector design the following general design recommendations can be made: Physical largest possible distance between DSL-line and power-line cable pins Symmetric arrangement of the different wires as well as the pins within the connector. Separate and electrical isolated contacts for the signal line shield and the outer motor cable shield for coupling connector within the line Pigtail style shielding connections need to be avoided within the connector; flying wire ends as short as possible (<50 mm Support a good low-ohmig contact of the shielding at the connectors Keep free wires as short as possible and twisted as long as possible within the connectors Disclaimer The max available cable length depends on signal frequency and propagation, the level of disturbances at a location as well as the general utilization (fix or moving). Information presented in here are for typical known applications. Not all specific conditions of each particular application or installation site can be tested and investigated upfront, e.g. different cable lengths and routings or different ground levels at the motor and drive controller locations. In a case of concerns or problems please contact SICK Stegmann GmbH with a detailed description of the situation for further support. References: [1] Impulse auf Leitungen elektrische Grundlagen (pulses on wires electrical basics) Thüringer, Rainer; FH Gießen/FB Elektro- und Informationstechnik [2] Transmission Lines and Crosstalk Canavero, Flavio G. EMC 2010; Technical University of Turin, Torino/Italy [3] HIPERFACE DSL Interface Manual; SICK-Stegmann GmbH, Donaueschingen, release 1.04 or higher, Aug. 24, 2012 8 Whitepaper SICK 2013-12-12