STRUCTURED CABLING SYSTEMS
|
|
|
- Terence Burns
- 10 years ago
- Views:
Transcription
1 STRUCTURED CABLING SYSTEMS by Mario Okle (12/98) 1 Structured Cabling Versus System Specific Cabling Since the mid 80s the trend towards structured cabling systems has continued. When we talk about structured cabling systems we mean a transmission media that fulfils the following characteristics: suitable for analogue and digital telephony, 95% of all computing networks, and video transmission patchable, i.e. in case of a change of a workplace, no additional cabling is needed except for the patch cable suitable for standard bit-rates from 64kbits up to 4/10/16/125 Mbits or even more (according to the standard used) Although the installation costs of a structured cabling system are high it becomes cost effective if the intended life of the infrastructure exceeds about 3 years: costs system spec. cabling structured cabling years 1
2 2 Structured Cabling Categories Today five different categories, also called "levels", have been defined and the definition of the next category is in preparation. The following table shows the specifications of the currently defined categories: Category Typical N/A Datarates [Mbits/s] Frequency [MHz] N/A 2.6 / N/A 2.6 / / / / / / / / / / / / / / / / / / / / / -32 Definition of the impedance: Level 1: Ohm Level 2-5: 100 Ohm +-15% In this document all references from this point referring to Structured Cabling Systems assumes category 5 specification or above. In this specification it is assumed that the cables are twisted in pairs. The specification does not define whether two or four pairs are used but WEY strongly recommend the use of cables with four pairs. 2
3 3 Shielded VS Unshielded Cabling Both, the unshielded and the shielded twisted pair cables have their advantages: Advantage Disadvantage Unshielded twisted pair: - relatively cheap - poor EMC - thin - Impedance tolerance* - cheaper installation - suitable for cat 5 Shielded twisted pair: - good EMC - more expensive - Impedance nearly constant - thicker - suitable for cat 5 and more *on a unshielded twisted pair cable not only the impedance has a bigger tolerance than the shielded one but also the attenuation and the cross-talk. The bigger tolerance of the electrical values of an unshielded twisted pair cable can be explained with the following drawing: The shield provides a defined environment for the enclosed wires, whereas in an unshielded cable this environment changes depending of the materials lying next to it. These materials will act as a variable capacitor in parallel to the main capacitor of the cable itself. Since it is nearly impossible to state what materials will be present along the route of the installed cables, it is therefore difficult to predict the result of the overall transmission line when using unshielded twisted pair cables. This effect is more prominent for the higher frequencies. 3
4 The following charts illustrate the difference of the impedance of a typical shielded and an unshielded twisted pair cat5 cable: Impedance of a shielded cable Impedance of an unshielded cable WEY do not recommend using unshielded twisted pair cables. 4
5 4 Installation / Connectivity For a structured cabling system WEY recommend the use of RJ45 connectors as shown in the following drawing: The four pairs should be connected according to the ISO8877: 5
6 5 Recommendations To ensure a excellent quality of the transmission of a wideband video signal (up to 150MHz) over distances of 200 and more metres the following recommendations should be taken into consideration when planning a structured cabling system: Reduce connections: ideally use a maximum of two patch cables on one run Install shielded twisted pair cables Max. attenuation (100MHz) 20 db/100m Max. cross-talk (100MHz) -50 db/100m Max. run length difference between pairs 4 ns/100m Don't use different types of twisted pair cables on the same transmission line Whenever possible use patch cables that are made out of the cable type installed Following cable types are tested and can be recommended: Cable Type Manufacturer (100 MHz) cross-talk (100MHz) Megaline 723 Kerpen 18.8 < Category6/Classe E Alcatel 18.8 < Uninet 7002 Dätwyler 17.9 < Uninet7702 Dätwyler 16.9 < Uninet 8002 Dätwyler 15.5 < Run-length difference [ns/100m] 6
Good EMC Design Principles: cable routing
Good EMC Design Principles: cable routing Keith Armstrong describes three important techniques for cable routing in metal cabinets, whether the cables are bundles of individual wires, or individual or
ROLINE THE Difference
ROLINE THE Difference The products of the brand ROLINE are developed for professional users and differ in their quality substantially from comparable products in the IT environment. The high compatibility
Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka
Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka What is a network? A computer network is two or more computers connected together using a telecommunication system for the purpose
Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.
Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip. Each dielectric configuration has different high-frequency characteristics. All configurations
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling
Crosstalk effects of shielded twisted pairs
This article deals with the modeling and simulation of shielded twisted pairs with CST CABLE STUDIO. The quality of braided shields is investigated with respect to perfect solid shields. Crosstalk effects
Specification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
SHEET 5 CABLE TELEVISION SYSTEM
SHEET 5 CABLE TELEVISION SYSTEM TRADITIONAL TELEVISION AND IPTV INTRODUCTION Access to full digital, as an inevitable technological development, clearly demonstrates the place of Digital Communication
SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS
STRUCTURED CABLING SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS INTRODUCTION In recent years, communications have taken on a crucial role in development for businesses. Communications
SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03
SICK AG WHITEPAPER Cable and connector for HIPERFACE DSL motor drive applications Information for cable manufacturers Note-2_03 Juergen Funkhaenel Application Engineer at SICK STEGMANN GmbH Donaueschingen
White Paper. Cat. 6A vs. Cat. 6 A. What s the Difference and Why Should I Care?
White Paper Cat. 6A vs. Cat. 6 A What s the Difference and Why Should I Care? Cat. 6A vs. Cat. 6 A What s the Difference and Why Should I Care? TABLE OF CONTENTS 1. Introduction...3 2. Component Standards
WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications
WHITEPAPER Cable and Connector for Hiperface dsl motor drive applications information for cable manufacturers Version 02 Content Information for cable manufacturers...3 Communication...3 Crosstalk & shielding...3
Security & Surveillance Cabling Systems
Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.
CoaXPress White Paper WP-2: Cabling Solutions
White Paper Authors Chris Beynon, Active Silicon Ltd Jochem Hermann, Adimec Advanced Image Systems BV Edited By Chris Beynon, Active Silicon Ltd Revision 1.0 27 November 2009 White Paper 1 Introduction...
Nexus Technology Review -- Exhibit A
Nexus Technology Review -- Exhibit A Background A. Types of DSL Lines DSL comes in many flavors: ADSL, ADSL2, ADSL2+, VDSL and VDSL2. Each DSL variant respectively operates up a higher frequency level.
Características. Starligh SA 9 de julio 1595 Córdoba Argentina - 0351-4809210 / 4119600
Balun Activo - BALUN_ACT Características Single Channel Active Video Transmitter Full-motion color video signal up to 3900ft(1200m) via UTP cat5e/6 NTSC, PAL & SECAM video format compatible Real-time transmission
AMP CO Plus Insert for Cat. 6 A Applications
Product Specification 108-93039 10/Mar/2011 Rev F AMP CO Plus Insert for Cat. 6 A Applications 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP* CO Plus
Application Note: How to Connect a Wired Ethernet Port to the WiPort
Application Note: How to Connect a Wired Ethernet Port to the WiPort Lantronix, Inc. 15353 Barranca Parkway Irvine, CA 92618 Tel: +1 (949) 453-3990 Revision A September 2004 Overview This application note
CCTV System Troubleshooting Guide
Wouldn t be nice to start and finish a CCTV System Project without running into any problems before, during and after the installation is completed. Well, in this article we will try and explain why we
Model CFA-24 Transparent Cable Farm Automation Switch
Model CFA-24 Transparent Cable Farm Automation Switch Ideal for Broadband Forum s ID-337 G.fast Certification and TR-249 VDSL2 Vectoring Testing High performance transparent solution designed to automate
428 MY HOME Structured cabling system for the home sector
428 MY HOME Structured cabling system for the home sector CONTENTS MY HOME Structured cabling system for the home sector General features. 384 General rules for installation. 400 Wiring diagrams. 404 Structured
1394 locking cables. Your locking cables for AVT IEEE 1394 cameras
Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal
Broadband access. Nils Holte, NTNU. NTNU Department of Telecommunications Kursdagene ved NTNU, Digitale telenett, 9. januar 2002 1.
Broadband access - properties of the copper network Nils Holte, Kursdagene ved, Digitale telenett, 9. januar 2002 1 Definition of broadband Overview Alternatives for fixed broadband access pair cable,
Grounding Demystified
Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%
HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks
HIGHSPEED ETHERNET THE NEED FOR SPEED Jim Duran, Product Manager - Americas WHITE PAPER Molex Premise Networks EXECUTIVE SUMMARY Over the years structured cabling systems have evolved significantly. This
R&Mfreenet Advanced Cat 6 A Unshielded Connection Module
R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions
10/100/1000BASE-T SFP Transceiver
10/100/1000BASE-T SFP Transceiver Features Support 10/100/1000BASE-T operation in host systems with SGMII interface Up to 1.25Gbps bi-direction data links Hot-pluggable SFP footprint Fully metallic enclosure
Network Design. Yiannos Mylonas
Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which
Contents. : AEOS Blue cabling and technical aspects. NEDAP N.V. IDEAS Information Bulletin No: H032. Date : 12 January 2016
NEDAP N.V. IDEAS Information Bulletin No: H032 Date : 12 January 2016 Concerns : AEOS Blue cabling and technical aspects AEOS Blue units can easily be connected to each other using the 485bus. This document
White paper. Shielded or unshielded network cables A matter of choice, electromagnetic environment and compatibility
White paper Shielded or unshielded network cables A matter of choice, electromagnetic environment and compatibility Table of contents 1. Introduction 3 2. Shielded versus unshielded network cables 3 3.
contents my HOmE - STrUCTUrEd CaBLing SYSTEm FOr THE HOmE SECTOr
contents my HOmE Structured cabling system for the home sector general features...................... 38 general rules for installation.............. 00 Wiring diagrams...................... 0 my HOmE
The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen
A technology primer from NORDX/CDT By, Eric d Allmen Foreword The Telecommunications Industry Association (TIA) and the International Standards Organization (ISO/IEC) are actively engaged in the development
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC by Paul Kish NORDX/CDT Chair TIA TR 41.8 Outline Market trends Standards development where we were where we are where we are going Beyond Category
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements
R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements on telecommunications ports Test & Measurement Data Sheet 01.00 R&S ENY81-CA6 Coupling Network At a glance The R&S ENY81-CA6
Card electrical characteristic, Parallelism & Reliability. Jung Keun Park Willtechnology
Description of the MEMS CIS Probe Card electrical characteristic, Parallelism & Reliability Jung Keun Park Willtechnology Background Overview Design limitation, Things to consider, Trend CIS Probe Card
Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk
Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk Paul Vanderlaan Product Development Engineer Belden Presented at BICSI January 20, 1999 Introduction New Parameters involving
Total Solutions Verification
Total Solutions Verification 3rd Party Electrical Performance Testing Author: Tom Boucino Applications Engineer Uniprise Solutions CommScope has always designed cables with connectivity in mind. Our engineers
Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair
Presentation; Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair 5 th April 2010 Paul Mathews MInstSMM, CCNA, MIEEE Global Channel Manager Media Types Physical Layer Cabling;
10 Gigabit Ethernet over copper: Unshielded, unprotected?
Technical Article 10 Gigabit Ethernet over copper: Unshielded, unprotected? Copyright 2005 Reichle & De-Massari AG (R&M). All rights reserved. Transmission and reproduction of this publication or parts
Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)
Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B) 1. Description and Specifications Contents 1.1 Description 1.2 1.2 Specifications 1.3 1.3 Tested parameters in production
Zero-Variable Wireless Infrastructure Deployment. Datasheet. Models: BM2HP, BM5HP. Completely integrated Radio
Zero-Variable Wireless Infrastructure Deployment Models: BM2HP, BM5HP Completely integrated Radio Directly plugs into any Antenna that has a Type N female connector Robust Weatherproof Design Overview
Data Communications Competence Center
Importance of Cable Balance For Improving Noise Susceptibility Data Communications Competence Center DCCC03101702 July 11, 2007 Summary In a study of category 5e and category 6 UTP cables, a strong correlation
Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port
Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port This app note applies to the following Lantronix Products: WiPort BG WiPort NR MatchPort BG MatchPort AR XPort Direct+
Balanced vs. Unbalanced Audio Interconnections
Revised 7/2/08 Balanced vs. Unbalanced Audio Interconnections In discussing the characteristics and performance of various interconnect systems; two points should be kept in mind. Balance is defined in
Network Engineers Everywhere:
Network Engineers Everywhere: Relax Your Minds Not Your Standards DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Patch Cable
Networks. The two main network types are: Peer networks
Networks Networking is all about sharing information and resources. Computers connected to a network can avail of many facilities not available to standalone computers: Share a printer or a plotter among
Coaxial Cables for Medium-Frequency Applications
Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Introduction Telecommunications technology is moving forward rapidly and the need for fast and reliable
Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable
Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable June 10, 2010 Contributors: Yinglin (Frank) Yang CommScope, Inc. Charles Seifert Ixia Ethernet Alliance 3855 SW 153 rd
How to Choose the Right Cable Category
How to Choose the Right Cable Category Why do I need a different category of cable? Not too long ago, when local area networks were being designed, each work area outlet typically consisted of one Category
FWA - technology and benefit
FWA - technology and benefit Professor Torleiv Maseng adj. Professor radio communications Department of Electroscience ( Inst. för Elektrovetenskap), Lund University, LTH FWA: Point to multipoint systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
Network Cabling Guide
Network Cabling Guide Poor or incorrectly installed network cabling can cause numerous problems with your computer network. Whilst we recommend that you employ a network / cabling specialist to wire and
Gigabit Ethernet on Copper Cabling Infrastructures
Gigabit Ethernet on Copper Cabling Infrastructures Overview of Gigabit Ethernet (1000Base-T) Ethernet was developed by the Xerox Corporation in the early 1970 s and has emerged as the dominant networking
Implementing Fast Ethernet
Implementing Fast Ethernet R The Next Generation of Ethernet Fast Ethernet (also known as IEEE 802.3u or 100BASE-T) is quickly becoming the successor to Ethernet as the network topology of choice. Fast
The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT
The Effect of Network Cabling on Bit Error Rate Performance By Paul Kish NORDX/CDT Table of Contents Introduction... 2 Probability of Causing Errors... 3 Noise Sources Contributing to Errors... 4 Bit Error
COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS
IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq
Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks
Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks By Galen Udell Belden CDT Networking 2006 Category 6 vs Category 5e Cabling Systems and Implications
This application note is written for a reader that is familiar with Ethernet hardware design.
AN18.6 SMSC Ethernet Physical Layer Layout Guidelines 1 Introduction 1.1 Audience 1.2 Overview SMSC Ethernet products are highly-integrated devices designed for 10 or 100 Mbps Ethernet systems. They are
Data Transmission. Raj Jain. Professor of CIS. The Ohio State University. Columbus, OH 43210 [email protected] http://www.cis.ohio-state.
Data Transmission Professor of CIS Columbus, OH 43210 [email protected] http://www.cis.ohio-state.edu/~jain/ 2-1 Overview Time Domain and Frequency Domain Bit, Hertz Decibels Data vs Signal Attenuation, Delay
STI 9 Edition 2/October 2000
STI 9 Edition 2/October 2000 Interface technical specifications for France Telecom s network Directive 1999/5/EC Characteristics of 2-wire/4-wire analogue leased link service access interfaces Summary:
Nathan Dayton ADNET. ADNET SYSTEMS, Inc. [email protected]. Slide Number 1
Nathan Dayton SYSTEMS, Inc. [email protected] Slide Number 1 NETWORK DESIGN Slide Number 2 Previously there have been two phases in the design of a network Department Design Interconnect Design
Mitel DECT Base Stations
Mitel DECT Base Stations On-site Mobility for Professionals The Mitel BS300 range of base stations offers a variety of coverage patterns to suit different situations. By choosing the right mix of base
Network/Multimedia Cables
Network/Multimedia Cables For LAN Installation, Home/Office Use Cat. 5, 6 Ethernet Cables Multi-Mode & Single-Mode Fiber Cables KVM Cables USB 2.0 Cables 1394 (FireWire) Cables F or the benefit of one-stop
If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:
This specification describes the situation of the Proximus network and services. It will be subject to modifications for corrections or when the network or the services will be modified. Please take into
Innovative cable technologies Business Unit Telecommunication Systems
Innovative cable technologies Business Unit Telecommunication Systems The Quality Connection Business Unit Telecommunication Systems www.leoni-telecom.com 2 Business Unit Telecommunication Systems With
INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION
TÜRK TELEKOMÜNİKASYON KASYON A.Ş. DIRECTORSHIP OF OPERATION AND MAINTENANCE Operation Directorate of Access Networks INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION ANKARA 2008 CONTENTS 1.
CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections
CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections RJ 45: (RJ xx: telephone connection interfaces, registered with the FCC, the U.S. Federal Communications Commission.) Pins: When
CAN - Wiring Notes on the Wiring of CAN-Bus Systems and the Cable Selection
CAN - Wiring Notes on the Wiring of CAN-Bus Systems and the Cable Selection Document file: I:\texte\Doku\MANUALS\CAN\VERDRAHT\Englisch\CANKAB35.en9 Date of print: 22.08.2003 Order no.: C.1300.02 Changes
G019.A (4/99) UNDERSTANDING COMMON MODE NOISE
UNDERSTANDING COMMON MODE NOISE PAGE 2 OF 7 TABLE OF CONTENTS 1 INTRODUCTION 2 DIFFERENTIAL MODE AND COMMON MODE SIGNALS 2.1 Differential Mode signals 2.2 Common Mode signals 3 DIFFERENTIAL AND COMMON
Simulation électromagnétique 3D et câblage, exemples dans l'automobile et aéronautique :
Simulation électromagnétique 3D et câblage, exemples dans l'automobile et aéronautique : CST, Christophe Morin 1 www.cst.com Agenda - Présentation CST - Simulation câblage dans modèle 3D - Exemples automobile
What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France
Title: Source: Author: Contact: What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France Jack Douglass Jack Douglass Paradyne Networks, Inc. Voice: 949-233-3558 Email:
Transmission of High-Speed Serial Signals Over Common Cable Media
Transmission of High-Speed Serial February 0 Introduction Technical Note TN066 Designers are often faced with moving serial data from one location to another, over moderate distances, and in the most efficient
ESD7484. 4-Line Ultra-Large Bandwidth ESD Protection
4-Line Ultra-Large Bandwidth ESD Protection Functional Description The ESD7484 chip is a monolithic, application specific discrete device dedicated to ESD protection of the HDMI connection. It also offers
The Quality Connection. Solutions@KERPEN IT Cabling Systems
The Quality Connection Solutions@KERPEN IT Cabling Systems Contents At a glance Introduction Page MegaLineNet and GigaLineNet Applications and market segments Page Copper Cables and Systems: MegaLineNet
V-DSL technology in the NBN
CommsDay Melbourne Congress 2013 V-DSL technology in the NBN Wednesday 9 th October 2013 Cliff Gibson Outline VDSL2 technologies which extend the capability of existing copper are expected to be included
Screened cable and data cable segregation
December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;
Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet
Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet Today s network managers know that modern demands on a network by its users can shrink bandwidth dramatically. Faster computers,
User Manual H5EA. HDMI Extender over Single Cat5e 7.1 CH AUDIO. rev: 110127 Made in Taiwan
User Manual H5EA HDMI Extender over Single Cat5e 7.1 CH AUDIO rev: 110127 Made in Taiwan Safety and Notice The H5EA HDMI Extender over Single Cat5e has been tested for conformance to safety regulations
This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:
UTP Technology In the late 1970s, unshielded twisted pair (UTP) cabling originated in the computer industry as a means of transmitting digital data over computer networks. This cable was designed to be
with Component Rating A Simple Perspective
Cat-6A UTP and Shielded with Component Rating A Simple Perspective Asef Baddar RCDD, DCD Sr. Technical Manager Leviton Middle East Category Specifications Agenda Terminology International & North America
LMR16TC Mini 10BASE-T Repeater. Installation Guide
LMR16TC Mini 10BASE-T Repeater Installation Guide LMR16TC Ethernet Mini Hub/Repeater Installation Guide The Lantronix LMR16TC is a multi-port hub that provides multi-media wiring connections for up to
Cable Analysis and Fault Detection using the Bode 100
Cable Analysis and Fault Detection using the Bode 100 By Stephan Synkule 2014 by OMICRON Lab V1.3 Visit www.omicron-lab.com for more information. Contact [email protected] for technical support.
Challenges of one pair automotive Ethernet from the wiring harness point of view
THE INTERNATIONAL EXPERTS FOR E/E-SOLUTIONS Challenges of one pair automotive Ethernet from the wiring harness point of view Advanced Automotive Cabling 2013, Stuttgart 2013-06-11 Speaker: Magnus Nigmann
Gigabit Switching Ethernet Media Converters - Product User Guide
Gigabit Switching Ethernet Media Converters - Product User Guide PL0338 Issue3 Introduction These Tyco Electronics Gigabit Media Converters translate between 1000Base-T copper and 1000Base-X fiber optic
CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults
CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±6 Faults Ciaran Brennan design features The LTC2875 is a robust CAN bus transceiver that features ±6 overvoltage and ±25kV ESD tolerance to reduce
CATV Balun II (500302)
CATV Balun II (500302) Application Guide Version 1.05 Oct 2010 MuxLab Inc. 2007-2010 1 Introduction Broadband CATV has experienced a steady growth in recent years due to the introduction of digital cable
LOW LOSS CABLE PAG. 1
LOW LOSS CABLE PAG. 1 INTRODUCTION Following many requests we received regarding the need for low-loss custom cable assemblies, we have set up a special production of high performance coaxial cable assemblies
Cabling Specifications
APPENDIX A This appendix provides cabling and pinout information for feature cards on the Cisco AS5350XM and Cisco AS5400XM universal gateways. It contains the following sections: 2-Port and 4-Port T1
Coupling/Decoupling Networks (CDN)
Coupling/Decoupling Networks (CDN) For immunity testing according to IEC / EN 61000-4-6 Immunity testing CDNs are the preferred coupling and decoupling devices, for reasons of test reproducibility and
VDSL2 POTS Splitters and Microfilters
VL2 POTS Splitters and Microfilters Introduction The purpose of this paper is to discuss the characteristics of splitters and microfilters for VL2 applications. Both CPE configurations are simplified into
Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk
Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk Introduction At the IEEE 802.3 Working Group meeting in July of 2012, the Next Generation BASE-T Call for
M-Bus Network Installation Notes
M-Bus Network Installation Notes 1 M-Bus Network Installation Notes This manual explains how to calculate the maximum M-Bus cable length depends on technical parameters of used cable and number of M-Bus
