Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER
|
|
|
- Beatrix Cobb
- 10 years ago
- Views:
Transcription
1 Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER
2 Questions to Ask When Planning the Cabling Plant Planning a copper cabling plant to support 10Gbps transmission is complicated today by the absence of ratified standards. There are, however, some questions you can ask that can help you navigate promises and claims in the market place and, ultimately, help you select the proper infrastructure to support future 10Gbps UTP applications. Do you really need a cabling plant that can support 10Gbps Ethernet over UTP? Historically speaking, cabling installed has always led the primary data rate. For example, over 90% of switch port sales in 1995 were for the 10Mbps Ethernet protocol. Yet in that same year, the primary UTP cabling installed was the 100Mbps Category 5, accounting for nearly 70% of UTP installed market share. Similarly in 2001, about 70% of switch port sales were for 100Mbps. In the same year, Category 5e and Category 6, which both support 1000Mbps, accounted for over 80% of UTP cabling installed. Of course, the next logical step in the data rate is another ten-fold increase to 10Gbps. With 10Gbps copper transceivers in development today and expected to market in 2006, the cabling plant must be able to handle the new protocol. Can Category 6 cabling support 10Gbps Ethernet over UTP? Actually, Category 6 cabling can support 10Gbps transmission but only to 55 meters, per TIA TR42.7, Cat 6 TSB155. However, this is a costly proposition. The added construction costs for more telecom rooms to accommodate 55 meters (vs. the standard 100 meters) are nominal compared to the added costs of purchasing additional Ethernet switches and other active equipment for each additional telecom room to support data, VoIP or other applications. What draft standards are important? Clearly, a 10Gbps UTP cabling solution should support the full 100 meters. From a standards perspective, TIA TR42.7, Cat A6-568 B.2 Addendum 10 is the current (May 2005) view to support 10Gbps transmission over UTP at 100 meters. Look for compliance with this standard as you shop for a solution. The draft standards also require full interoperability and backwards compatibility.
3 What about shielded solutions? Space, time and cost constraints were the drivers that led to the development of UTP cabling in lieu of shielded twisted pair (STP) solutions. Those reasons are still prevalent today. Still there are manufacturers that do not yet have a UTP solution and are promoting STP shielded solutions for 10Gbps transmission over copper. However, shielded cabling typically requires more space in racks, cabinets, and raceways. Furthermore, grounding and bonding is a concern for shielded cable installations. Time to train and whether or not to ground at the station and the closet varies geographically and by whom you ask. Shielded cable construction will continue to be more costly than UTP cable construction, as well as more expensive to install. In fact, a recent ADC study concluded that an STP network would typically cost three times more than a UTP network. Without TIA/EIA standards in place, what are good decision criteria for selecting a 10Gbps solution for UTP? The cabling industry TIA/EIA does not drive the electrical parameters needed to run transmission protocols. It is the IEEE that develops proposed protocols, understands what is needed from an electrical perspective, and then gives TIA/EIA responsibility for developing measurable parameters for the cable and connectors. When in doubt, follow the IEEE lead. The IEEE Study Group was formed to discuss how best to approach running 10Gbps transmission over a copper infrastructure. This group is composed of representatives from chip manufacturers, switch manufacturers, and cabling and connectivity manufacturers. Discussions within the group include which protocol encoding to use and how it relates to the needed bandwidth or frequency range of the cabling infrastructure. As of this writing (May 2005), it appears as though the IEEE Study Group has recommended a frequency range out to 500 MHz. A key measurement established by this IEEE study group is Shannon s Capacity. Shannon s Capacity is a measure of how efficiently a cable can transmit data at different rates, expressed in bits per second. The IEEE Study Group concluded that achieving 10Gbps transmission, at 100 meters requires at least 18Gbps from the cabling solution. The additional capacity is required to compensate for active hardware noise parameters such as jitter and quantization. Realizing that the cabling plant is designed to support the requirements of active electronics, a Shannon s Capacity of at least 18Gbps is a good measure to consider when evaluating 10Gbps UTP solutions. ADC s CopperTen 10Gbps UTP solution demonstrated 21Gbps over 100 meters for the IEEE Study Group in August 2003, easily exceeding the Shannon s Capacity minimum requirement of 18Gbps for all pair combinations. Today, CopperTen has achieved greater than 31 Gbps over 100 meters offering more than enough additional throughput to handle noise induced by active electronics. Have vendors had a tough time achieving 10Gbps over UTP at 100 meters? Yes. By August 2003, the IEEE Study Group had seen no vendor UTP solution that could deliver 18Gbps over UTP at 100 meters. In fact, the apparent lack of vendor solutions led the IEEE Study Group to three possible recommendations: lower the data rate to 2.5Gbps for Category 6 UTP; reduce the length of the supported channel to 55 meters from the industry standard 100 meters for Category 6 UTP; and use shielded solutions and abandon UTP as a transport medium for 10Gbps over copper. KRONE, recently acquired by ADC, took on the challenge and returned to the IEEE Study Group just weeks later to demonstrate CopperTen, the first augmented Category 6 cable capable of transmitting at least 18Gbps over 100 meters. After this demonstration, the IEEE Study Group voted 64 to 0 to move forward with a 10Gbps solution over UTP at 100 meters. What is the biggest challenge to achieving a minimum of 18Gbps over UTP? For Category 5e and Category 6 solutions, the pair-topair relationship is paramount to making good cable. While these electrical characteristics remain important, taming alien crosstalk remains the toughest hurdle for any 10Gbps UTP solution at 100 meters. Alien crosstalk is the noise heard on a pair within a cable that is generated by another cable directly adjacent to it. Manufacturers of active equipment do not like random events such as alien crosstalk. While noise between pairs within a cable can be predicted and eliminated within the active hardware, unpredictable alien crosstalk cannot. Crosstalk between pairs in a single UTP cable is often cancelled out by varying the twist rate between different pairs and increasing the distance between pairs. The often-used star filler of Category 6 cable creates separation by pushing pairs within the cable as close to the jacket as possible. While this design reduces crosstalk between pairs within the same cable, it leaves some pair combinations between cables in the bundle susceptible to high levels of crosstalk. This problem is magnified at the higher frequencies of 500 MHz to 625 MHz of 10Gbps transmission. Page 2
4 Instead of using the typical star filler, ADC s CopperTen uses an elliptical offset star filler that achieves a high degree of separation between pairs in adjacent cables in a bundle. The shape of the elongated star filler results in an oblique shape for each cable. Bundled cables now have sufficient separation between same lay length pairs to prevent alien crosstalk. In a bundle, the random separation of cables keeps cable pairs of the same twist rate within different cables at a greater distance from one another reducing alien crosstalk. Because alien crosstalk presents the steepest challenge to 10Gbps over UTP, insist on seeing test results for the 6- around-1 cable configuration. Is cable insulation important? Choice of insulation materials is critical in producing 10Gbps UTP cable. One key measure of insulation quality is the Dielectric Constant the lower the Dielectric Constant of the insulation material of a cable, the better the resistance to breakdown when an electrical field is applied. As a reference, the Dielectric Constant of air the best insulation available is 1.0. Dielectric Constants for other cable insulation materials are as follows: FEP 2.1; FRPE 2.5; PVC 3.6; glass 4.3. The choice of insulation materials plays a large part in cable performance. Insulation affects the speed at which a signal propagates through a cable. Speed is measured as the Nominal Velocity of Propagation (NVP), expressed as a percentage of the speed of light in a vacuum (300 million m/sec), with the speed of light in a vacuum given a value of 1. The speed of the signal over a multi-pair data communications cable can be attributed to two main factors: the speed at which the signal is traveling (NVP) and the total length of the cable pair, which allows for twist rate. Both of these parameters combined are measured as Propagation Delay, the time it takes for a signal to propagate from one end of a circuit to the other. Therefore, cable constructed with insulation with a lower Dielectric Constant offering less resistance to an electrical field offers a higher NVP. Insulation for ADC s CopperTen cabling system uses the unique AirEs technology that combines FEP with integrated air pocket channels. Through the introduction of air pockets between the FEP and copper conductor, the total Dielectric Constant is reduced from 2.0 for FEP alone to about 1.8 for FEP with air a 31%improvement over an FEP-only insulation system. The reduced dielectric loss translates into a direct improvement in signal loss and improved NVP or, said differently, stronger signal strength. Of course, other 10Gbps cables may use only FEP or FRPE insulation both of which have a higher Dielectric Constant that weakens signal strength. Improving the Dielectric Constant of FEP by adding air the AireES technology offers higher performance cable for 10Gbps transmission. Why is electrical cable pair length important? The choice of cable insulation plays a role in electrical cable pair length. Besides NVP, the other factor that affects the speed of a signal over a multi-pair communications cable is the electrical length of the cable pair. Electrical length is always more than physical length of the sheath due to twisting of the conductors. As described above, the effect of faster NVP is low Propagation Delay. However, Propagation Delay is also a function of the actual length of the pair, including the twist. The greater the twist rate, the longer the pair and the larger the Propagation Delay. In fact, excessive propagation delay is often due to cable that is just too long. By utilizing the higher quality AirES insulation with air channels between FEP and the copper conductor, CopperTen cable requires a reduced amount of twist on each pair. By reducing the electrical length of pairs, Propagation Delay is reduced, improving the speed of the signal between transmitter and receiver especially important as cabling runs reach the 100 meter physical limit. What is the impact of Delay Skew on 10Gbps cable performance? Delay Skew is the difference in time each signal requires to arrive on all four pairs. Of course, optimal performance and error free transmission means that signals should arrive at the receiver as close to the same time as possible. Delay skew of 45nS to 50nS between the fastest and the slowest pairs is marginally acceptable for data communications. Lower skew is better. Delay skew below 25nS is desirable. To achieve Near End Cross Talk (NEXT) performance, most cable solutions must vary the twist lays greatly. NEXT is, of course, more of a problem at higher frequencies, such as with the 500MHz or better for 10Gbps solutions. To solve NEXT, some solutions actually use different insulation for different pairs within the same sheath, which ends up as unique twist ratios (i.e, varying electrical length of cable pairs) per pair. Unfortunately, greater variation in twist lays means an increase in Delay Skew a costly compromise when it comes to data communications. While receivers can handle slight variations is delay, a large skew will make it impossible to recombine the original signal. Page 3
5 With the AirES innovation of introducing air the best insulator against noise as an insulator, crosstalk is reduced without having to greatly increase twist lay variation. There is simply less crosstalk between pairs because of reduced noise due to superior insulation. Therefore, AirES technology and reduced need for twist lay variation results in fewer bit errors as the propagation delay between the fastest and slowest pairs is less than 20nS. How should warranty promises be evaluated? Until 568B.2 is ratified, it is impossible for any vendor to guarantee full compliance to a standard that does not yet exist. Until standards are established, it is more important for a 10Gbps UTP solution to meet the throughput and capacity requirements established by the electronics industry Shannon s Capacity of 18Gbps. As the standards evolve, manufacturers will continually tweak individual parameters such as NEXT and return loss, as we saw with Category 5e and Category 6. Still, the only hard design number for 10Gbps over UTP today is 18Gbps throughput as defined by IEEE. ADC offers a warranty that backs 18Gbps channel capacity and supports the current draft of 568B.2 Addendum 10. Is cable diameter an issue with 10Gbps UTP solutions? Patch cords that employ solid wire sacrifice flexibility and bend radii mechanics because solid wire is not as forgiving and easy to install or manage as stranded wire. Solid wire patch cord conductors are more prone to breakage when repeatedly flexed during normal lifetime usage. In addition, solid wire patch cords often have reliability issues due to the difficultly of crimping RJ45 plugs on solid wire. As compared to stranded wire patch cords, solid wire patch cords also place unnecessary stress upon the connectors in NICs, patch panels and switches, because of their uncompromising stature. Conclusion It is evident that 10Gbps transmission over a copper cabling plant will soon become the common design specification. While lack of standards today present some risk in the decision making process, other factors offer guidance when choosing cable, plugs and connectors to support future 10Gbps applications. Choosing a solution with the highest quality insulation such as the AirEs technology used for CopperTen offers immediate evidence of superior performance. Solutions that can guarantee Shannon s Capacity of 18Gbps at 100 meters offer the best assurance that the channel will support 10Gbps transmission when standards are ratified next year. Larger cable diameters can affect not only density but also ease of installation and maintenance. To achieve the requirements of draft standards for 10Gbps transmission over UTP, some manufacturers today have 10Gbps UTP cable with outside diameters (OD) ranging from 0.310" to 0.330" rather large in comparison to the nominal size for conduit fill of 0.290" for the plenum CopperTen, which has a varying OD from 0.275" to 0.310" due to its elliptical shape. Outside diameter is also a consideration for patch cords. ADC s CopperTen patch cord cable has an OD of 0.270" which is dramatically smaller when compared to the OD of the competitive cable which range from 0.310" to 0.330". While these differences seem small, they become significant installation and maintenance issues, especially in dense applications. Are patch cords changing for 10Gbps transmission? There is one change to look for when evaluating patch cords for use in a 10Gbps channel stranded vs. solid wire. Some products have moved to solid wire patch cords to achieve 10Gbps performance. Yet solid wire patch cords present concerns. Page 4
6 WHITE PAPER Web Site: From North America, Call Toll Free: Outside of North America: Fax: For a listing of ADC s global sales office locations, please refer to our web site. ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer /05 Original 2005 ADC Telecommunications, Inc. All Rights Reserved
How to Choose the Right Cable Category
How to Choose the Right Cable Category Why do I need a different category of cable? Not too long ago, when local area networks were being designed, each work area outlet typically consisted of one Category
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling
Network Design. Yiannos Mylonas
Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which
White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems
White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems Asef Baddar, RCDD Principal Engineer / Applications Engineering Supervisor Leviton Network Solutions C/7 - #1928 Table of Contents Background
HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks
HIGHSPEED ETHERNET THE NEED FOR SPEED Jim Duran, Product Manager - Americas WHITE PAPER Molex Premise Networks EXECUTIVE SUMMARY Over the years structured cabling systems have evolved significantly. This
Enhanced Category 5 Cabling System Engineering for Performance
Engineering for Performance Table of Contents 2 Introduction 2 Where Did It Come From? 2 Enhanced Category 5 Performance What to Test The Link The Channel Don t Forget the Cable Assembly 4 Performance
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC by Paul Kish NORDX/CDT Chair TIA TR 41.8 Outline Market trends Standards development where we were where we are where we are going Beyond Category
Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable
Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable June 10, 2010 Contributors: Yinglin (Frank) Yang CommScope, Inc. Charles Seifert Ixia Ethernet Alliance 3855 SW 153 rd
Network Engineers Everywhere:
Network Engineers Everywhere: Relax Your Minds Not Your Standards DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Patch Cable
Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks
Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks By Galen Udell Belden CDT Networking 2006 Category 6 vs Category 5e Cabling Systems and Implications
Gigabit Ethernet on Copper Cabling Infrastructures
Gigabit Ethernet on Copper Cabling Infrastructures Overview of Gigabit Ethernet (1000Base-T) Ethernet was developed by the Xerox Corporation in the early 1970 s and has emerged as the dominant networking
Data Communications Competence Center
Importance of Cable Balance For Improving Noise Susceptibility Data Communications Competence Center DCCC03101702 July 11, 2007 Summary In a study of category 5e and category 6 UTP cables, a strong correlation
WHITE PAPER December, 2001
Is Superior Essex Outside Plant Copper Cable Rated Category 3? The applicability of the Category 3 specification to outside plant cables is sometimes misunderstood. This white paper examines that issue,
Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk
Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk Paul Vanderlaan Product Development Engineer Belden Presented at BICSI January 20, 1999 Introduction New Parameters involving
Copper Patch Cords. Impact On Network Performance and Reliability
Copper Patch Cords Impact On Network Performance and Reliability 1 The Impact of Copper Patch Cords on Network Performance and Reliability As network infrastructures continue to have a higher impact on
The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen
A technology primer from NORDX/CDT By, Eric d Allmen Foreword The Telecommunications Industry Association (TIA) and the International Standards Organization (ISO/IEC) are actively engaged in the development
ADC Structured Cabling Solutions
ADC Structured Cabling Solutions The highest performing cross-connect system in the world HighBand Wall Mount Patching Solution Reliable, secure and cost effective ADC s HighBand cross connect solution
Networks. The two main network types are: Peer networks
Networks Networking is all about sharing information and resources. Computers connected to a network can avail of many facilities not available to standalone computers: Share a printer or a plotter among
HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)
Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission
Developing the Green Data Center
Products and Solutions to Support Energy Efficiency Ordering Guide Table of Contents Developing the Green Data Center Introduction...5 Airflow Management in the Data Center...6 Angled Panels Glide Cable
Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair
Presentation; Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair 5 th April 2010 Paul Mathews MInstSMM, CCNA, MIEEE Global Channel Manager Media Types Physical Layer Cabling;
White Paper. Cat. 6A vs. Cat. 6 A. What s the Difference and Why Should I Care?
White Paper Cat. 6A vs. Cat. 6 A What s the Difference and Why Should I Care? Cat. 6A vs. Cat. 6 A What s the Difference and Why Should I Care? TABLE OF CONTENTS 1. Introduction...3 2. Component Standards
Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel
Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel Introduction When network managers decide on a cabling system,
Managing High-Density Fiber in the Data Center: Three Real-World Case Studies
Managing High-Density Fiber in the Data Center: Three Real-World Case Studies CHALLENGE In today s data center, fiber optic links have become more vital than ever for transmitting data to and from a large
1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.
Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment
Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)
within the Unified Physical Infrastructure SM (UPI) www.panduit.com WP-11 April 2007 Introduction With the ratification of the IEEE 802.3an 10GBASE-T copper standard, end users now have more media options
ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard.
WIRING STANDARD INTRODUCTION This standard defines a telecommunications wiring system for North Dakota State Agencies, offices or buildings that will support a multi-product environment. The purpose of
Chapter 4 Connecting to the Internet through an ISP
Chapter 4 Connecting to the Internet through an ISP 1. According to Cisco what two things are essential to gaining access to the internet? a. ISPs are essential to gaining access to the Internet. b. No
Implementing Fast Ethernet
Implementing Fast Ethernet R The Next Generation of Ethernet Fast Ethernet (also known as IEEE 802.3u or 100BASE-T) is quickly becoming the successor to Ethernet as the network topology of choice. Fast
Ethernet Patch Cord Wiring
Ethernet Patch Cord Wiring C ONTENTS Ethernet Patch Cords & RJ-45 Connectors... 2 Ethernet Patch Cords and UTP Cabling... 3 What s all the twisting about?... 4 Ethernet Applications... 5 568A & 568B Wiring
Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka
Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka What is a network? A computer network is two or more computers connected together using a telecommunication system for the purpose
Nexus Technology Review -- Exhibit A
Nexus Technology Review -- Exhibit A Background A. Types of DSL Lines DSL comes in many flavors: ADSL, ADSL2, ADSL2+, VDSL and VDSL2. Each DSL variant respectively operates up a higher frequency level.
Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet
Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet Today s network managers know that modern demands on a network by its users can shrink bandwidth dramatically. Faster computers,
Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.
1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking
This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:
UTP Technology In the late 1970s, unshielded twisted pair (UTP) cabling originated in the computer industry as a means of transmitting digital data over computer networks. This cable was designed to be
An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware
for CAT 6A Connecting Hardware Written by: Antoine Pelletier Engineer, Global Cabling Products Intertek www.intertek-etlsemko.com 1-800-WORLDLAB Introduction The telecommunication industry recently achieved
with Component Rating A Simple Perspective
Cat-6A UTP and Shielded with Component Rating A Simple Perspective Asef Baddar RCDD, DCD Sr. Technical Manager Leviton Middle East Category Specifications Agenda Terminology International & North America
The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges
The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges Table of contents Channel, Basic Link and Permanent Link defined....................... 2 Critical Performance Parameters......
ADC-APC Integrated Cisco Data Center Solutions
Advanced Infrastructure Solution for Cisco Data Center 3.0 Ordering Guide ADC-APC Integrated Cisco Data Center Solutions The evolution of data centers is happening before our eyes. This is due to the
Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)
Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems) Introduction The purpose of this document is to: 1) provide background information beneficial to specifiers
100BASE-SX Fast Ethernet:
100BASE-SX Fast Ethernet: A Cost Effective Migration Path for Fiber in the Horizontal Prepared by the Fiber Optics LAN Section of the Telecommunications Industry Association February 2000 2000 TIA Fiber
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
Total Solutions Verification
Total Solutions Verification 3rd Party Electrical Performance Testing Author: Tom Boucino Applications Engineer Uniprise Solutions CommScope has always designed cables with connectivity in mind. Our engineers
CommScope Intelligent Building Infrastructure Solutions (IBIS)
SYSTIMAX Solutions CommScope Intelligent Building Infrastructure Solutions (IBIS) Questions & Answers Q. What is an Intelligent Building? A. An intelligent building can be defined as one which provides
Coaxial Cables for Medium-Frequency Applications
Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Introduction Telecommunications technology is moving forward rapidly and the need for fast and reliable
Upon completing this chapter, you will be able to: Describe the primary types and uses of twisted-pair cables Describe the primary types and uses of
Upon completing this chapter, you will be able to: Describe the primary types and uses of twisted-pair cables Describe the primary types and uses of coaxial cables Describe the primary types and uses of
STRANDED AND SOLID CONDUCTOR
STRANDED AND SOLID CONDUCTOR ETHERNET CABLES CONTENTS C ATEGORY- TYPE CABLES...2 S OLID CABLE CONDUCTORS: ALONE, BUT NOT STRANDED...3 S TRANDED CABLE CONDUCTORS: STRANDED WITH A TWIST...4 A NOTE ON WIRE
Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres
Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres White Paper Nexans Cabling Solutions September 2006 Executive Summary Planning for the unknown is always a difficult
Specifying an IT Cabling System
Specifying an IT Cabling System This guide will help you produce a specification for an IT cabling system that meets your organisation s needs and gives you value for money. You will be able to give your
SYSTIMAX Copper Solutions Designed for the Digital Generation
SYSTIMAX Copper Solutions Designed for the Digital Generation SYSTIMAX Structured Connectivity Solutions www.systimax.com SYSTIMAX Solutions is the global leader in the enterprise cabling sector with a
Developing the Green Data Centre
Products and Solutions to Support Energy Efficiency Ordering Guide Table of Contents Supporting the Green Data Centre Table of Contents Introduction...5 Airflow Management in the Data Centre...6 Angled
Understanding the Electrical Performance of Category Cables
Understanding the Electrical Performance of Category Cables By: Mike Levesque, Mike Karg & Himmeler Themistocle Obsessed with cable solutions. Understanding the Electrical Performance of Category Cables
Structured and Point to Point Network Cabling for Industrial Automation
Structured and Point to Point Network Cabling for Industrial Automation Introduction Industrial automation systems are undergoing dramatic transformations that require businesses to adopt new strategies
SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03
SICK AG WHITEPAPER Cable and connector for HIPERFACE DSL motor drive applications Information for cable manufacturers Note-2_03 Juergen Funkhaenel Application Engineer at SICK STEGMANN GmbH Donaueschingen
Impedance Matching. Throughput SOLUTIONS NETWORK PERFORMANCE. Only the TrueNet Impedance-matched System Protects Network Performance
Throughput SOLUTIONS Impedance Matching Protects NETWORK PERFORMANCE Original 100BaseT MLT-3 signal transmission Only the TrueNet Impedance-matched System Protects Network Performance Networks for today
The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration
The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration Bill Charuk, SR Product Manager, Data Center Solutions Introduction With the advent of data centers in communication infrastructure, various
Security & Surveillance Cabling Systems
Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.
WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications
WHITEPAPER Cable and Connector for Hiperface dsl motor drive applications information for cable manufacturers Version 02 Content Information for cable manufacturers...3 Communication...3 Crosstalk & shielding...3
DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
Transmission of High-Speed Serial Signals Over Common Cable Media
Transmission of High-Speed Serial February 0 Introduction Technical Note TN066 Designers are often faced with moving serial data from one location to another, over moderate distances, and in the most efficient
10 Gigabit Ethernet over copper: Unshielded, unprotected?
Technical Article 10 Gigabit Ethernet over copper: Unshielded, unprotected? Copyright 2005 Reichle & De-Massari AG (R&M). All rights reserved. Transmission and reproduction of this publication or parts
Upgrading Path to High Speed Fiber Optic Networks
SYSTIMAX Solutions Upgrading Path to High Speed Fiber Optic Networks White Paper April, 2008 www.commscope.com Contents Connectivity Method A 4 Upgrading Method A to Parallel Optics 4 Connectivity Method
SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS
STRUCTURED CABLING SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS INTRODUCTION In recent years, communications have taken on a crucial role in development for businesses. Communications
Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity
Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity Needs in the Data Center With the continued requirement for expansion and growth in the data center, infrastructures must provide
Accelerating Light. Copper Cabling Solutions. Category 6A
Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity
DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com
DATA CENTER NETWORK INFRASTRUCTURE Cable and Connectivity for the Most Demanding Networks Customer-focused, technology-driven, quality-assured for an unparalleled RETURN ON infrastructure investment DATA
Sending A/V Signals Over Twisted Pair Cables: An Introduction. What is A/V over twisted pair?... 2
Sending A/V Signals Over Twisted Pair s: An Introduction Table of Contents What is A/V over twisted pair?... 2 What can be accommodated with A/V over twisted pair?... 3 What applications can effectively
Uniprise Solutions COAX 101. White Paper. www.commscope.com
Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-5 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 5: Symmetrical pair/quad cables with transmission characteristics up
The Three Principles of Data Center Infrastructure Design WHITE PAPER
The Three Principles of Data Center Infrastructure Design WHITE PAPER The Three Principles of Data Center Infrastructure Design Understand These Three Principles and You ll: Lower your total cost of ownership
Cable Discharge Event
Cable Discharge Event 1.0 Introduction The widespread use of electronic equipment in various environments exposes semiconductor devices to potentially destructive Electro Static Discharge (ESD). Semiconductor
SMARTen 24 STP Patch Panels
Features Support 24 ports per 1U High performance, supportable bandwidth up to 500MHz supporting IEEE 802.3an 10Gbps application Conform to ANSI/TIA/EIA-568-B.2-10, ISO/IEC 11801 2.1 edition and CENELEC
The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT
The Effect of Network Cabling on Bit Error Rate Performance By Paul Kish NORDX/CDT Table of Contents Introduction... 2 Probability of Causing Errors... 3 Noise Sources Contributing to Errors... 4 Bit Error
SMARTen 24 UTP Patch Panels
Features High density, 24 ports per 1U High performance, supportable bandwidth up to 500MHz supporting IEEE 802.3an 10Gbps application Special cap design for minimizing Alien Cross-Talk Conform to ANSI/TIA/EIA-568-B.2-10,
How To Get A Better Signal From A Fiber To A Coax Cable
Gigabit Transmission What s the Limit? Fanny Mlinarsky Page 1 What s the Limit? Speed Faster higher frequency higher attenuation less headroom Distance Longer higher attenuation more jitter less headroom
TIA-942 Data Centre Standards Overview WHITE PAPER
TIA-942 Data Centre Standards Overview WHITE PAPER TIA-942 Data Centre Standards Overview For the past 20 years, cabling standards have been the cornerstone of ensuring proper design, installation, and
ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER
ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect Introduction The primary
Gigabit Ethernet: Architectural Design and Issues
Gigabit Ethernet: Architectural Design and Issues Professor of Computer and Information Sciences Columbus, OH 43210 http://www.cis.ohio-state.edu/~jain/ 9-1 Overview Distance-Bandwidth Principle 10 Mbps
Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.
Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip. Each dielectric configuration has different high-frequency characteristics. All configurations
Industrial Ethernet The Perfect Cable for an Imperfect Environment
1 Industrial Ethernet The Perfect Cable for an Imperfect Environment Written by: David Fausz, Engineer, Communications Products TABLE OF CONTENTS BACKGROUND 1 APPLICATIONS AND 2 ELECTRICAL PERFORMANCE
Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer
SYSTIMAX Solutions Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer Issue 2 Draft 1 June 2010 Contents Overview 3 GigaSPEED X10D Guaranteed Channel Performance
Category 6 UTP - Cabling System
AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP
Optimizing Infrastructure Support For Storage Area Networks
Optimizing Infrastructure Support For Storage Area Networks December 2008 Optimizing infrastructure support for Storage Area Networks Mission critical IT systems increasingly rely on the ability to handle
1000BASE-T: Gigabit Ethernet. over Category. 5 copper. cabling. Acronyms and abbreviations
1000BASE-T: Gigabit Ethernet over Category 5 copper cabling By Christopher T. Di Minico Acronyms and abbreviations ANSI American National Standards Institute BER Bit error rate DSL Digital subscriber line
The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT
The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings Focus on the IBDN System 4800LX from NORDX/CDT Table of Contents Introduction... 3 Bandwidth and Information
Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network
Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network WP4270 Issued: June 2011 Authors: Carl Roberts and Merrion Edwards Introduction
ATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification
ATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification Abstract Presented in this document are the standards to implement Electrical & Optical Ethernet components, cabling, connections,
High Speed Ethernet. Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF
High Speed Ethernet Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF Hubs and Switches Hubs and Switches Shared Medium Hub The total capacity in the shared medium hub configuration (figure
Using Pre-Emphasis and Equalization with Stratix GX
Introduction White Paper Using Pre-Emphasis and Equalization with Stratix GX New high speed serial interfaces provide a major benefit to designers looking to provide greater data bandwidth across the backplanes
WHITE PAPER. Creating the Green Data Center. Simple Measures to Reduce Energy Consumption
WHITE PAPER Creating the Green Data Center Simple Measures to Reduce Energy Consumption Introduction Energy Awareness Driving Decisions in the DataCenter The continued thirst for energy is a recurring
InstaPATCH Cu Cabling Solutions for Data Centers
SYSTIMAX Solutions InstaPATCH Cu Cabling Solutions for Data Centers Design Guidelines August 2008 www.commscope.com Contents Overview 1 Instapatch Cu Solution Specification 2 Harness Assembly Design 3
Category 8 Cabling Standards Update
White Paper Category 8 Cabling Standards Update TIA TR42.7 Study Group for Class II Limits Contents 1 Background 3 2 Impact of this approval on Category 7 A cabling 3 3 Differences between Class I and
Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk
Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk Introduction At the IEEE 802.3 Working Group meeting in July of 2012, the Next Generation BASE-T Call for
Innovative Connectivity Solution for Maximum Performance and Security
Innovative Connectivity Solution for Maximum Performance and Security Financial Institutions Supports high performance backbone which enables transfer of real-time financial information through voice,