Transcription
1 MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference :
2 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following address : ETIC TELECOMMUNICATIONS 13 Chemin du vieux chêne MEYLAN FRANCE TEL : FAX : [email protected] web : This user guide applies to the following product references with the manufacturing index 07 MDM192-0 MDM192-1 Modem designed for 9 to 40 VDC supply voltage Modem designed for 40 to 60 VDC supply voltage Page 2 USER GUIDE ref MDM192
3 CONTENTS 1. PRODUCT OVERVIEW NETWORK TOPOLOGIES MODEM PERFORMANCE Line characteristics Number of modems that can be connected to a line Range DESCRIPTION Leds DIP switches Connectors INSTALLATION Setting the data rate and the byte frame Matching the modem to the transmission line RS232 local interface RS485 / RS422 local interface Connection to the line : Point to point Connection to the line : Multidrop Test Frame MDM192 USER GUIDE ref Page 3
4 Page 4 USER GUIDE ref MDM192
5 1. Product overview The MDM192 modem provides half-duplex data transmission between PLCs (for instance), on a 2 wires cable over up to 30 Km. Point to point or multi-drops transmission 16 PLCs (and even more) can be connected to the same line. (2 wires twisted and shielded pair) at a data rate up to b/s. Reliability The modems are connected in parallel to the line. If one modem fails, it does not prevent the rest of the network from transmitting normally. Line isolation The modem is isolated from the line through a 4000 VRMS transformer. Local interface The modem provides an RS232, RS422 and RS485 asynchronous interface. The data rate ranges from 1200 to b/s (7 or 8 bits with or without parity, 1 start bit, 1 or 2 stop bits). Transmission delay time The digital technique used provides a very low delay of transmission (only 3 characters time). Compatibility The MDM 192 is able to transmit most PLC protocols among which : Rockwell : Siemens : Schneider Electric : Omron : DF1, DH485 PROFIBUS DP MODBUS, UNITELWAY SYSMACWAY... and generally speaking any master / slave asynchronous protocol. MDM192 USER GUIDE ref Page 5
6 2. Network topologies Point to point Bus Star Page 6 USER GUIDE ref MDM192
7 3. Modem performance 3.1. Line characteristics The MDM 192 is designed to be connected to any 2 wires line; even if its diameter is very large or very small, and even if it is a coaxial cable. However, the performance of the product is the best when it is connected to a twisted shielded pair Number of modems that can be connected to a line Up to 16 modems can be connected to the same line. See table 1 below. If more than 16 modems have to be connected to the line, it will work properly but the range performance (whole length of the line) will decrease Range The range (whole length of the line) depends upon the data rate, the line quality and the number of modems connected to the line. If the line is noisy, the performances may decrease. To increase the range, it is possible to repeat the data using the following design : Repeater RS485 MDM192 USER GUIDE ref Page 7
8 TABLE 1 : Range Range with 2 modems connected to the line Cable diameter in mm (50 nf / km) Data rate 0,4 0,5 0,6 0, b/s 13 km 16 km 20 km 26 km 34 km 2400 b/s 13 km 16 km 20 km 26 km 34 km 4800 b/s 13 km 16 km 20 km 26 km 34 km 9600 b/s 10 km 12 km 15 km 20 km 25 km b/s 6 km 7 km 9 km 12 km 15 km Range with 8 modems connected to the line Cable diameter in mm (50 nf / km) Data rate 0,4 0,5 0,6 0, b/s 12 km 14 km 18 km 24 km 29 km 2400 b/s 12 km 14 km 18 km 24 km 29 km 4800 b/s 12 km 14 km 18 km 24 km 29 km 9600 b/s 9 km 11 km 13 km 18 km 22 km b/s 5 km 6 km 7 km 10 km 12 km Range with 16 modems connected to the line Cable diameter in mm (50 nf / km) Data rate 0,4 0,5 0,6 0, b/s 11 km 13 km 16 km 22 km 26 km 2400 b/s 11 km 13 km 16 km 22 km 26 km 4800 b/s 11 km 13 km 16 km 22 km 26 km 9600 b/s 7 km 9 km 11 km 15 km 18 km b/s 4 km 5 km 6 km 9 km 11 km Page 8 USER GUIDE ref MDM192
9 4. Description MDM192 Up to evolution index 8 MDM192 From evolution index Leds RD TD Data reception from the line Data transmission to the line Data reception errors Test frame transmission (if SW1-8 is ON) The led is blinking Power supply MDM192 USER GUIDE ref Page 9
10 4.2. DIP switches TABLE 2 SW1 DIP SWITCHES (8 positions) FRAME SW1-1 1 byte = 10 bits OFF 8 b + start + 1 stop 7 b + parity + start + 1 stop 7 b + start + 2 stops 1 byte = 11 bits ON 8 b + parity + start + 1 stop 7 b + parity + start + 2 stops DATA RATE SW1-2 SW1-3 SW b/s For compatibility with evolution 01 to 06 OFF OFF OFF b/s Normal position OFF OFF ON b/s For compatibility with evolution 01 to 06 OFF ON OFF b/s Normal position OFF ON ON b/s For compatibility with evolution 01 to 06 ON OFF OFF b/s Normal position ON OFF ON 2400 b/s ON ON OFF 1200 b/s ON ON ON Reserved SW1-4 SW1-5 SW1-6 Mandatory OFF OFF OFF TEST Test Frame transmission Normal operation SW1-8 ON OFF Page 10 USER GUIDE ref MDM192
11 TABLE 3 : SW2 DIP SWITCHES Adapting the modem to the line quality, if necessary From the 9 evolution index only Line impedance Output R SW2-1 SW2-2 > Ohm OFF OFF Default position 270 < Zc < Ohm ON OFF 190 < Zc < Ohm OFF ON Zc < Ohm ON ON TABLE 4 : SW3 DIP SWITCHES Selecting the value of the line matching Resistor From the 9 evolution index only Line impedance Matching R SW3-1 SW3-2 > Ohm OFF OFF Default position 270 < Zc < Ohm ON OFF 190 < Zc < Ohm OFF ON Zc < Ohm ON ON Any modification of the dip switches position operates immediately. MDM192 USER GUIDE ref Page 11
12 4.3. Connectors TABLE 5 : 10 points screw block Line and local RS485 and RS422 interface Pin Nr Signal Function Line 1 L1 Line signal wire 1 2 L2 Line signal wire 2 3 Adp Line adaptation bridging points 2 and NC 5 - NC 6 - NC Local RS485 and RS422 interface 7 RS422 B RS422 Transmission polarity B (to MDM192) 8 RS422 A RS422 Transmission polarity A (to MDM192) 9 RS485 B RS422 Reception polarity B (to the local data terminal) or RS485 polarity B 10 RS485 A RS422 Reception polarity A (to the local data terminal) or RS485 polarity A TABLE 6 : DB9 fem. RS232 CONNECTOR Not isolated local Interface Pin Nr Circuits Designation Terminal-Modem 1 CD 109 Carrier detect 2 RX 104 Data reception 3 TX 103 Data emission 4 DTR 108 Data terminal ready 5 SG 102 Signal ground 6 DSR 107 Data set ready 7 RTS 105 Request to send 8 CTS 106 Clear to send 9 RI 125 Ring indicator TABLE 7 : 2 pins screw-block Supply voltage!! CHECK THE PRODUCT REFERENCE ON THE RIGHT SIDE OF THE PRODUCT Pin Nr Signal Function to 40 VDC supply voltage for reference MDM to 60 VDC supply voltage for reference MDM Signal ground Page 12 USER GUIDE ref MDM192
13 5. Installation 5.1. Setting the data rate and the byte frame The MDM192 modem does not adapt the data rate between the line and the serial interface (RS232 or RS485 or RS422); it transmits at the same data rate over the line and over the serial interface. Byte frame The switch Nr 1 of the SW1 block must be set OFF or ON according to the number of bits of each byte (10 or 11 bits); see table 2. Data rate The switches Nr 2 and 3 and 7 of the SW1 block must be set in the position corresponding to the data rate in use. MDM192 USER GUIDE ref Page 13
14 5.2. Matching the modem to the transmission line This paragraph applies to the products the evolution index of which is 9 or higher (see the identification label on the side of the product). It describes how to adapt the modem to the characteristics of the line, using the SW2 and SW3 switches blocks, to get the best possible transmission distance. The SW2 and SW3 swiches blocks are located on the side of the product. The products the evolution index of which is 9 or higher, are fully compatible with older products (index 8 or lower); in that case, all the switches of the SW2 and SW3 switches bocks (on the side of the product) have to be left OFF. Principle The SW2 and SW3 switches blocks have to be set according to the characteristics of the line represented by the line impedance (Zc). The line impedance Zc can be calculated as follows : Zc = square root [2 X R/Cω] with R= Wire resistance (Ohm / Km) C = Mutual capacitance between the wires (Farad / Km) ω = Signal pulsation (6,28 x F) To avoid calculations, refer to table 8 just below. TABLE 8 : Line impedance / wire diameter and cable mutual capacitance Wire diameter mm 0,4 0,4 0,6 0,6 0,8 0,8 1 1 Mutual capacity nf/ km Zc at 1200 or 2400 or 4800 b/s Zc at 9600 b/s Zc at b/s SW2 and SW3 switches blocks setting All the modems connected to the same line have to be set identically. Set the switches according to the table 9 below. TABLE 9 : SW2 and SW3 setting Line impedance Output R Value of the matching R Ohm SW 2-1 Sw2-2 SW3-1 SW3-2 >350 OFF OFF OFF OFF 270 < Zc < 350 ON OFF ON OFF 190 < Zc < 270 OFF ON OFF ON Zc < 190 ON ON ON ON Page 14 USER GUIDE ref MDM192
15 5.3. RS232 local interface The RS232 interface is available on the DB9 connector on the front panel. The data terminal must be less than 10 meters far from the modem. The connection to a PC is achieved with a straight cable ( 1 to 1, 2 to 2 etc ) 5.4. RS485 / RS422 local interface The RS422 and RS485 interfaces are available on the 10 pts screw block. Up to 16 data terminals can be connected to the local RS485 bus. The data terminals must be less than 100 meters far from the modem. - RS485 / RS422 polarization The MDM 192 includes line polarization resistors. - RS485 / RS422 line adaptation For a several meters long connection over the RS485 local interface, it is not necessary to adapt the RS485 line. For longer distances, connect a 120 Ohm resistor at each end of the line. MDM192 USER GUIDE ref Page 15
16 5.5. Connection to the line : Point to point Line connection The line has to be connected to the 10 points screw block points 1 and 2 The wires can be inverted. The MDM192 includes the line adaptation resistor. It has to be brought into service at each end of the line by bridging points 2 and 3 of the 10 pins screw block Shield If the cable is shielded, the shield must be connected to the protective earth pin available at the bottom of the product. Page 16 USER GUIDE ref MDM192
17 5.6. Connection to the line : Multidrop Connecting to the line the modems located at each end (modems 1 and 5 of the drawing above) : The 2 wires of the line have to be connected to the 10 points screw block points 1 and 2. The wires can be inverted. The MDM192 includes the line adaptation resistor. It has to be brought into service in each modem located at the end of the line by bridging points 2 and 3 of the 10 pins screw block Shield : If the cable is shielded, the shield must be connected to the protective earth pin available at the bottom of the product. MDM192 USER GUIDE ref Page 17
18 Connecting to the line a modem not located at the end of the line (modems 2 to 4 of the drawing above) : The 2 wires of the line have to be connected to the points 1 and 2 of the 10 points screw block The wires can be inverted. Line Line 10 pts screw block MDM192 Nr 1 2 L1 L2 Shield If the cable is shielded, the shield must be connected to the protective earth pin available at the bottom of the product Test Frame For test purposes, the MDM 192 is able to transmit permanently a character frame. That function is available only if the data rate is set at a value from 4800 to b/s. To enable the test function, set to ON the switch Nr8 of the SW1 switches block (SW1-8) located on the front side of the product. The red led blinks each time a test frame is transmitted. The test frame is transmitted at the data rate which has been set, but any case with 1 stop and no parity (8N1). The frame can be displayed with a PC using the ModemView software (Copyright ETIC), or any terminal emulation software. Page 18 USER GUIDE ref MDM192
19 Local Interface Data Range (informative value) Configuration Size Isolation from the line EMC Security Thunder Supply voltage Power consumption Operating T CARACTERISTICS RS485 - RS422 - RS232 Asynchronous : 7 or 8 bits Parity : none / even / odd 1 start, 1 or 2 stops b/s Up to 30 Km 8 DIPswitches 115 x 38 x 96 mm (h, l, p) Transformer : 4000 Vrms EN EN EN et -5 9 to 40 VDC reference MDM to 57 VDC reference MDM ma - 24 VDC -20 C / + 60 C (dry air) MDM192 USER GUIDE ref Page 19
20 13, Chemin du Vieux Chêne Meylan France Tél : Fax : [email protected] Web :
M-Bus Network Installation Notes
M-Bus Network Installation Notes 1 M-Bus Network Installation Notes This manual explains how to calculate the maximum M-Bus cable length depends on technical parameters of used cable and number of M-Bus
Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.
Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring
RAS-E. Industrial router & RAS server & firewall. User manual Document reference : 9016309-04
RAS-E Industrial router & RAS server & firewall User manual Document reference : 9016309-04 For the firmware version V2.30 and the following versions The RAS-E router is manufactured by ETIC TELECOM 13
How To Set Up A 366101 Modem (Marc) Model 366101 (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar
DIN Rail Mounted Leased Line Modem Users Manual 366-101 Rev. 2 Copyright 2008 Miille Applied Research Co., Inc. Houston, Texas This page is left blank intentionally Page i TABLE OF CONTENTS LIST OF FIGURES...
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
SWITCHED TELEPHONE NETWORK LEASED LINE
Distribué par : Contact : [email protected] Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com MTi 133-1 V34 33 600 b/s INDUSTRIAL MODEM SWITCHED
FOM-5A, 6A. Asynchronous Fiber Optic Modem
FOM-5A, 6A Asynchronous Fiber Optic Modem FEATURES Asynchronous transmission at up to 19.2 kbps Transmission range up to 3 km (1.8 mi), regardless of data rate Full- or half-duplex Transfers one control
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A + - DLM CTS RTS DTR DSR
AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A User Manual + - CD CTS RTS DTR. DSR RI RX TX PHONE LINE DLM Dial-Up / Leased-Line Modem Dial-Up / Leased-Line Modem CONTENTS
Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4
Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4 eng May 2007 35009581_02 2 335009581 02 May 2007 Document Set Document Set At a Glance This documentation
OPT-700 - SERIAL TO FIBER OPTIC CONVERTER
USER S MANUAL OPT-700 - SERIAL TO FIBER OPTIC CONVERTER JUL / 05 OPT-700 VERSION 1 TM FOUNDATION OPT700ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date
User Manual IC-485AI 2002-09-27
User Manual IC-485AI Note: This equipment has been tested and found to comply ith the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS
SERIAL I/O COMMON PROTOCOLS RS-232 Fundamentals What is RS-232 RS-232 is a popular communications interface for connecting modems and data acquisition devices (i.e. GPS receivers, electronic balances,
Single channel data transceiver module WIZ2-434
Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules
RS-232 COMMUNICATIONS
Technical Note D64 0815 RS-232 COMMUNICATIONS RS-232 is an Electronics Industries Association (EIA) standard designed to aid in connecting equipment together for serial communications. The standard specifies
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
Modbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
Encore Controller to Router Connections
Encore Presentation System Encore Controller to Router Connections Contents: Scope... 2 EXT COMM Pinouts... 2 Cable Connection Straight Through... 3 Cable Connection Null Modem... 3 Lantronix Ethernet
Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable
Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable Designed for use with the COMbricks SALT repeater All baudrates Redundant
Teleservice via RS232 interface XC100/XC200
User Manual 10/10 MN0500005Z-EN replaces 07/04 AWB74-1490GB Teleservice via RS interface XC100/XC00 All brand and product names are trademarks or registered trademarks of the owner concerned. Emergency
HSG Engineering Tech Bulletin
Specifications subject to change OCT 2013; Rev. 1.3 HSG Engineering Tech Bulletin Recommended RS-485 Wiring for NetAXS-4/NetAXS-123 Loops Overview This document provides the recommended RS-485 wiring for
Application Note 83 Fundamentals of RS 232 Serial Communications
Application Note 83 Fundamentals of Serial Communications Due to it s relative simplicity and low hardware overhead (as compared to parallel interfacing), serial communications is used extensively within
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
s!nus-elektrotechnikai bt. Industrial IT & Automation
USB/PPI+ Optoelectronic isolated USB/PPI adapter Optoelectronic isolated USB/PPI adapter, can replace Siemens 6ES7 901-3DB30-0XA0, the largest communication distance of up to 2 kilometers. Not support
Why you need to monitor serial communication?
Why you need to monitor serial communication Background RS232/RS422 provides 2 data lines for each data channel. One is for transmitting data and the other for receiving. Because of these two separate
KOM200. Industrial Serial to Fiber Media Converter. User s Manual
KOM200 s Manual 200911 KOM200 Industrial Serial to Fiber Media Converter s Manual KYLAND Technology Co., Ltd. 1 KOM200 s Manual 200911 Table of contents CHAPTER 1: PRODUCT OVERVIEW---------------- 3 CHAPTER
ISHIDA BC-3000. Scale to Scale Communications
ISHIDA BC-3000 Scale to Scale Communications Setup Procedure & Operating Instructions March 2006 PN 94561 Revision History Date Page Description March 2006 Initial publication August 2006 2 Added RS-232
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
One Port Serial Server Users Manual Model ESP901, ESP901E
One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements
Making a DB to RJ45 adapter.
Making a DB to RJ45 adapter. DB9 to RJ45 adapters are often used in combination with a RS232 repeater for extending the distance of a serial RS232 link, but can be used for any adapter or converter purposes.
Moxa TCC-100/100I User s Guide
Moxa TCC-100/100I User s Guide Seventh Edition, June 2008 www.moxa.com/product 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. Moxa TCC-100/100I User s Guide The software
Manual Serial PCI Cards
Manual Serial PCI Cards W&T Models 13011, 13410 13411, 13610 13611, 13812 Version 1.4 Subject to error and alteration 37 01/2005 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make
Cable Pinouts. SRP I/O Module
Cable Pinouts C This appendix lists the cables and connector pinout assignments for the cables used with the ERX-700 series and ERX-1400 series. Topic Page SRP I/O Module C-1 CT1 and CE1 I/O Modules C-4
RJ11 RS-232 Interface
H NS TN30 RJ11 RS-232 Interface 1.0 General The back panel of the CPP-3794 provides a combination of 9 pin DB connectors and RJ11 connectors for connecting RS-232 serial cables. The 9 pin DB connector
s!nus-elektrotechnikai bt. Industrial IT & Automation
PC/MPI+ RS232 isolated Siemens S7-300/400 PLC Programming adapter Optoelectronic isolated RS232/MPI,Siemens S7-300/400 PLC Programming adapter cable,with communication indicator,can replace Siemens 6ES7
USB to RS-422/485 Serial Adapter
USB to RS-422/485 Serial Adapter User Manual Ver. 2.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2
Modbus RTU Master Communications
Modbus RTU Master Communications This document describes the operation of Modbus RTU Master from the user interface point of view. Use this information as a supplement to the Serial Communications User
Documentation. M-Bus 130-mbx
Documentation M-Bus 130-mbx Introduction The mx M-Bus module is part of the mx Smart Slot communications family. With the integrated SmartSlot technology, mx systems ag offers automatic consumer data read-out
MODBUS TCP to RTU/ASCII Gateway. User s Manual
MODBUS TCP to RTU/ASCII Gateway User s Manual 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING THE HARDWARE CONNECTIONS... 5 2.1 POWER CONNECTION...
MOTION COORDINATOR MC206X Quick Connection Guide
I/O Connector 1 Analogue In / Inputs 0-7 5 Way Connector Power /CANbus I/O Connector 2 24V Power / I/O 8-15 I/O Connector 3 WDOG / Ref Encoder / Analogue Outputs USB Serial A Serial B Axes 0-3 Encoder
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
User Guide. Westermo Teleindustri AB 6600-2204 TD-23. Leased Line V.23 Modem Multidrop applications. www.westermo.com
User Guide 6600-2204 TD-23 Westermo Teleindustri AB Leased Line V.23 Modem Multidrop applications www.westermo.com Legal information The contents of this document are provided as is. Except as required
USB TO SERIAL ADAPTER
USB TO SERIAL ADAPTER (Model: U232-P9V2) SPECIFICATIONS CONTENTS 1. GENERAL SPECIFICATIONS... 1 1.1 PRODUCT SURFACE... 1 1.2 PRODUCT DIMENSION... 2 1.3 PRODUCT FEATURES... 3 1.4 PRODUCT SPECIFICATIONS...
Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI
Technical Manual For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Caller ID.com WHOZZ CALLING? POS 2 Caller ID Monitoring Unit Technical Manual For use with Caller ID signaling
Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)
February 2015 February 2015 Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) This document describes how to connect an electricity meter to a SolarEdge device (inverters,
Introduction: Implementation of the MVI56-MCM module for modbus communications:
Introduction: Implementation of the MVI56-MCM module for modbus communications: Initial configuration of the module should be done using the sample ladder file for the mvi56mcm module. This can be obtained
LTM-1338B. Plus Communications Manual
LTM-1338B Plus Communications Manual 2000. Best Power, Necedah, Wisconsin All rights reserved. Best Power The System Setup option from the Main Menu on the front panel is passwordprotected. The default
BACnet Automation Interface Module (Network Version)
Sense +V Tx Rx LAN LINK Over ARCNET KBaud BACnet Rx BACnet Tx Archive Valid Port S Tx Port S Rx Low Battery Network- Enhanced Access Default MSTP PTP = Download Required on Rnet and Port S IP Address IP
s!nus-elektrotechnikai bt. Industrial IT & Automation
USER MANUAL s!nus-elektrotechnikai bt. USB/PPIM+ Siemens S7-200 USB/PPI Multi-Master Cable USB/RS485 Isolated For all PPI-Bus System Summary: USB / PPIM + is the PPI Multi-Master programming Cable which
BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1
BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved
RS485 & RS422 Basics
RUA ALVARO CHAVES, 155 PORTO ALEGRE RS BRASIL 90220-040 TEL: +55 (51) 3323 3600 FAX: +55 (51) 3323 3644 [email protected] RS485 & RS422 Basics INTRODUCTION The 422 and 485 standards, as they are known
USB to serial chip CH340
The DataSheet of CH340 (the first) 1 1. Introduction USB to serial chip CH340 English DataSheet Version: 1D http://wch.cn CH340 is a USB bus convert chip and it can realize USB convert to serial interface,
Bluetooth HC-06 with serial port module Easy guide
1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550
Communication Setup Application Note
Communication Setup Application Note This Application Note describes how to install and set up communication between the inverter and the SolarEdge Monitoring Server. This document contains the following
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
RS-232/422/485, Power over Ethernet
IP-COM-M IP-COMi-M IP-COM-M PoE IP-COMi-M PoE RS-232 RS-232/422/485 RS-232, Power over Ethernet RS-232/422/485, Power over Ethernet Edition: September 2012 The computer programs provided with the hardware
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System
RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System RTM X42 is an innovative system that utilizes force measuring rollers to capture the tension of individual wires or strands,
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
GM1200E Interface Cable
GM00E Interface Cable SPK+ Mic Aud Ext PTT SPK/0 Ext Alrm RJ Plug PTT/0 Flat Tx Audio SCI Data In SCI Data Out Emerg/ NPD In Motorola Accessory Connector (rear view) 0 Ign Det Flat Rx Audio CTS SW B+ Hook
1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0
1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0 1.1 Modbus Protocol Overview This section provides basic information for interfacing the Eastron Smart meter to a Modbus Protocol
ADACSNET USB Control Module
ADACSNET USB Control Module Installation Guide Termination Switch 2-Pin SensorNet Connection Features and Hookup The USB Control Module contains the following: - USB port: Connects to the host computer.
Fanuc 0 M/T Model C Serial (RS232) Connection Guide
Memex Automation Inc., Burlington, Ontario Canada L7N 1 http://www.memex.ca Fanuc 0 M/T Model C Serial (RS232) Connection Guide The Fanuc 0-C control has two RS-232 interfaces. Interface number 1 (M5)
Advanced Data Capture and Control Systems
Advanced Data Capture and Control Systems Tronisoft Limited Email: [email protected] Web: www.tronisoft.com RS232 To 3.3V TTL User Guide RS232 to 3.3V TTL Signal Converter Modules P/N: 9651 Document
SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming
Somfy Digital Network (SDN) Installation and Programming SSoomffyy SSyysst teemss IInncc.. 1 Table of Contents 1 General Information and Features... 3 1.1 ILT2 Motor... 3 1.2 SDN Switches... 4 1.3 ILT2
A RF18 Remote control receiver MODULE
A RF18 Remote control receiver MODULE User Guide No part of this document may be reproduced or transmitted (in electronic or paper version, photocopy) without Adeunis RF consent. This document is subject
LBNP16312. RS-232/485/422 serial device server. User manual
Tu Sitio de Automatización! LBNP16312 RS-232/485/422 serial device server User manual Summarize-----------------------------------------------------------------------------14-3 Package checklist---------------------------------------------------------------------14-3
User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)
Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for
Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation
Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions
Auxiliary equipment for communication with the EuroProt protective devices
Auxiliary equipment for communication with the EuroProt protective devices RS232 cable This cable is used to connect the RS232 connector located on the front panel of the EuroProt devices to the 9 pin
Connector and Cable Specifications
APPENDIX B This appendix provides the following cabling and pinout information for the Cisco IAD1101 integrated access device: Console Port Signals and Pinouts Ethernet Connector Pinouts Analog Subscriber
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
IPG/7700 Hardware Manual SYSTECH. Document number 80-001099-7 Revision A
IPG/7700 Hardware Manual SYSTECH C O R P O R A T I O N Document number 80-001099-7 Revision A Created 2010, and Protected Under the U.S. Copyright Act of 1976. Copyright 2010, SYSTECH Corporation All Rights
Bluetooth UART/RS232 Module
Introduction BLUEMORE600 is a professional, slim, wireless module ready for integration in brand new or existing electronic products. Based on CSR chipset BC03MM it s fully compatible for Serial Port profiles.
Industrial Bar Code Scanners
DX8200A Industrial Bar Code Scanners Configuration SW Tool ACR4 technology PackTrack ASTRA technology APPLICATIONS Postal/Courier parcel sorting and tracking Automated warehousing identification systems
ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE
ELAN DIGITAL SYSTEMS LTD. LITTLE PARK FARM ROAD, SEGENSWORTH WEST, FAREHAM, HANTS. PO15 5SJ. TEL: (44) (0)1489 579799 FAX: (44) (0)1489 577516 e-mail: [email protected] website: http://www.pccard.co.uk
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
Connector and Cable Specifications
APPENDIXB This chapter describes the connector and cable specifications. Connector Specifications, page B-1l Cable and Adapter Specifications, page B-5 Connector Specifications 10/100/1000 Ports, page
DK40 Datasheet & Hardware manual Version 2
DK40 Datasheet & Hardware manual Version 2 IPC@CHIP DK40 Evaluation module Beck IPC GmbH http://www.bcl.de page 1 of 11 Table of contents Table of contents... 2 Basic description... 3 Characteristics...
2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:
COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
Table of Contents. Creating a VC1000 Network... 3
2 Table of Contents Creating a VC1000 Network... 3 Topology... 3 Unit ddressing... 4 Terminating Resistors... 5 Shielding... 5 Interconnecting the common... 6 ias Resistors... 6 VC1000 Hardware Configuration...
Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products
Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products 90000253_E Digi International Inc. 2005. Digi, Digi International, the Digi logo, the Making Device Networking Easy logo, Digi
Date Rev. Details Author
Jtech engineering ltd J - Te c h E n g i n e e ring, L t d. 11080 Bond Boulevard Delta BC V4E 1M7 Canada Tel: 604 543 6272 Fax: 604 543 6476 http://www.jtecheng.com AUTODIALER USER S MANUAL REVISION HISTORY
Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount)
Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount) QUALITY COMMUNICATIONS PRODUCTS Made in the U.S.A. 11-1010-002 INTRODUCTION
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual CMC-0205820-01 Table of Content 1 Introduction to CMC-PD01... 2 1.1 Product Introduction... 2 1.2 Features... 2 2 Product Profile and Outline...
Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0
3DLevelScanner II Different Ways of Connecting to 3DLevelScanner II A.P.M Automation Solutions LTD. www.apm-solutions.com Version 3.0 2 Different Ways of Connecting to 3DLevelScanner II Version 3.0 Table
SyncLink GT2/GT4 Serial Adapter
SyncLink GT2/GT4 Serial Adapter Hardware User s Manual MicroGate Systems, Ltd http://www.microgate.com MicroGate and SyncLink are registered trademarks of MicroGate Systems, Ltd. Copyright 2008 2012 MicroGate
Computer Control of Satellite Antennas
Computer Control of Satellite Antennas This paper discusses the use of the serial interface available on Research Concepts, Inc. (RCI) satellite antenna controllers. The serial communications interface