Managing. Energy management and power analysis



Similar documents
Applications. diris_826_a_1_gb_cat

Power Meter Series 700

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

A project to optimise quality and energy efficiency must include metering

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Energy Management Energy Meter Type EM23 DIN

Quick Connect. quick - simple - efficient.

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

EARTH LEAKAGE PROTECTION: CONTENTS

Application/Connection Examples

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Low Voltage Products

Polyphase kwh Electricity Meter

Eaton s E-Series protective relay family

M2M The measure of efficiency

Maximum Demand Control

Energy Management Power Analyzer Type WM14-96 Basic Version

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

DIRIS A40/A41 RS485 JBUS/MODBUS. Operating instructions F GB D I NL E P

7. Reactive energy compensation

EM-PQ 1500 Power Quality Monitor. Operating Manual

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

PLA 44. Power quality analyzer. User and service manual. BMR trading

Electrical Network Management System

3-phase, bidirectional energy meter

3-Phase Energy meter with serial S-Bus interface

Low voltage electrical distribution. Electronic trip units. User manual 09/2009

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

Thyristor-controlled power supplies and battery chargers

Static energy meters

Monitoring,Telemaintenance,... HACCP. Innovative Supermarket solutions. Tecnologia ed Evoluzione

Installation manual. Generator Paralleling Controller GPC multi-line C

Technical note NT588 NT604 NT695 NT782

Digital multimeters DMG

Electrical Measuring Instruments

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Counter for Energy. We make energy measurable and secure your future.

NC-12 Modbus Application

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

Remote Monitoring and REC 501 Control Unit Product Guide

Alliance System Ordering Guide

Electrical measurement and control M.5. CVM Power analyzers

Rack mounted telephone- and leased line modem for industrial applications

Power monitoring unit type VAMP 260

ABB RTU560A Series CMU & Modules

T Substation Maintenance and Commissioning Test Equipment

1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Metering for today s systems

IntesisBox Modbus Server Fidelio IP

ZC-24DO CANopen I/O Module: 24 Digital Outputs

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Paralleling and Protection Unit Type PPU multi-line E

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

3U 4V 4A L1 L2 L3 V2 = 314 V3 = -84 N = -14 > ensuring high performance C.A 8332B C.A 8334B C.A 8335 POWER AND ENERGY QUALITY ANALYSERS

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Energy Management Energy Analyzer Type EM24 DIN

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Telephone- and leased line modem for industrial applications TD-36

Meter, Meter Reading Instrument (MRI) and Base Computer Software for Meter Data Management (MDM) Vivek Pathak Secure Meters

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

Contents. Energy saving screen saver. Harmonics measurings up the 15 th or 50 th. Relays with OR option. 0.5% accuracy in voltage and current

SECTION DETECTION AND ALARM

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

M1000 Process Alarm Monitor

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet

One Meter Works for Both Energy Saving and Power Quality Surveillance

PCS0100en Persy Control Services B.V. Netherlands

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Documentation. M-Bus 130-mbx

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

Metering Devices IQ Analyzer 6400/6600 Series

Installation and operating instructions

Communicate and view data from meters with one simple device

Heating Controller. Building Technologies HVAC Products

Electronic Control Devices The European Product Catalogue 2007

Power Meter Series 800

Nemo 96HD/HD+ MODBUS

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

38 Series - Relay interface modules A

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Digital and Analog I/O

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

1.44 kw Programmable DC Power Supplies XLN Series

Transcription:

management and power analysis Power monitors IN 96 and 144 - Selection table... 68 - IN 96, recdigit NOUS... 70 - IN 144, recdigit POWER... 72 - Multi-display recisplay... 73 Winthor software... 74 Managing 67

ENERIS MIN AVG MAX recdigit POWER M k W h k V A r Hz cos SELECT MOE PROG ENERIS V A kw Rpm C C SELECT ENTER Additional Screen PROG POWER MONITORS - IN 96 & IN 144 Selection table recdigit NOUS recdigit POWER recisplay IN 96 power monitor IN 144 power monitor IN 144 multi-display S POWER MONITORS - IN 96 & IN 144 68 Mainly suited for networks: Local display* 3 x U and 3 x V 3 x I 3 x P 3 x Q 3 x S P total Q total S total 3 x PF (inductance - capacitance) PF total (inductance - capacitance) Frequency Metering and energy management* E active positive E active negative E reactive positive E reactive negative E apparent positive E apparent negative Load curve Synchronising input Hour meter (h, 1/10, 1/100) isplay LV Q Quality LV isplay Q Quality M Management Additional S Screen MV/LV MV/LV MV/LV MV/LV ❶ Multi-display ModBus/JBus up to 6 parameters chosen on the associated products. Power quality TH-V et TH-I (max) 3 x TH-V and 3 x TH-I (inst, min, max) In (I neutral) Communication Alarm threshold relay output ModBus/JBus link ❹ ❷ ❸ ❸ 2 x RS485 Options 1 2 metering-pulse outputs (Ea & Er) 2 2 analogue outputs 3 option 1 + 2 4 4 metering-pulse outputs (Ea+, Ea-, Er+, Er-) ❺ Instantaneous values Instantaneous and maximum values Instantaneous, maximum/minimum and average values (programmable t from 1 to 99 minutes) ❶ ❷ ❸ ❹ Recording of 1200 active and reactive power values, average over a programmable t (i.e: recording of 8 days with a t of 10 min). ALARM - monitoring of min. and max. values on V, U, I, P, Q, S, F, PF, TH-V, TH-I or PULSE - on active, reactive or apparent energy. Recording of the 3 latest overthresholds (date, time, duration, max. value, average value of overshoot) on 3 U, 3 I, P total and PF via digital RS485 link. Analogue output programmable on front panel among the following parameters : V, U, I, P, Q, S (by phase and global), PF and F : 0 20 ma or 4 20 ma. * These parameters are also accessible via the digital RS485 link.

POWER MONITORS - IN 96 & IN 144 General specifications Technical characteristics recdigit NOUS recdigit POWER Nodus E Nodus EQ all models isplay Currrent inputs secondary primary consumption Voltage inputs ratings VT ratio consumption per phase Frequency Type of network Power supply igital output rate parity Alarm output Pulse output Analogue output ata storage Environmental conditions Basic metrological characteristics V, U, I P, Q, S PF / Frequency E active / E reactive / E apparent Hour meter TH-U and TH-I Analogue output Mechanical characteristics Connection: Weight Fastening current circuit voltage circuit other (RS, relay ) Black LC on light background Amber LC on back -lit black Red LE on black background (size 12 mm) (size 10 mm) background (size 10 mm) isplay refresh period: 1 s (10 s on TH-I and TH-V) 3-phase uninsulated 3-phase insulated In: 1 A and 5 A (selection when programming) In: 1 A or 5 A (selection when ordering) Programmable from 1 to 5000 A Programmable from 1 or 5 to 19999 A < 1 VA to 1.2 Vn < 2 VA to 1.2 In 3-phases + neutral Un = 230 Vac P/N /400 Vac P/P Un : 57.7 Vac P/N /100 Vac P/P or 230 Vac P/N / 400 Vac P/P Programmable from 1.00 to 20 Programmable from 1.0000 to 9999.9999 < 1 VA to 1.2 Vn < 0.5 VA to Un 45 to 65 Hz 3 or 4-wire, balanced or not - 1, 2 or 3 CT mounting 3 or 4-wire, balanced or not - 2 or 3 CT mounting 110 / 127 / 230 / 400 Vac ±15% or 24 to 110 Vdc ±20% 20 90 Vdc / 20 70 Vac or 90 360 Vdc / 70 260 Vac or 125 to 230 Vdc ±20% or 190 460 Vac RS485 (2-wire + shielding) half duplex, ModBus/JBus protocol RTU mode 1200 to 19200 bauds 300 to 19200 bauds Even or odd or no parity Even or no parity - Potential-free contact - Time delay adjustable from 1 to 99 s (steps: 1 s) Hysteresis: 5% (adjustable via JBus from 1 to 10%) or Polarised transistorised transmitter, IN SO 43864 standard Pulse weight: 1 or 10 or 100 (kwh or kvarh or kvah) Pulse weight: 0.1 to 9999.9 (kwh or kvarh) Pulse width: 300 ms Pulse width: 100 or 500 ms - Permitted load: 500 Ω max, response time: 400 ms 10 years (25 C) Operating temperature: 0 to +55 C Operating temperature: -10 to +55 C Storage temperature: -20 to +60 C Storage temperature: -25 to +70 C 0.5% R 0.2% R 1% R 0.5% R 0.01 / 0.1 Hz Class 1 according to IEC 61036 / Class 2 according to IEC 61268 / 1% R - 250 ppm - - 2% - 0.5% FS * Terminal strip with double headed screws for 6 mm 2 wires Locking and plug-in terminal for 2.5 mm 2 wires Plug-in terminal for 2.5 mm 2 wires Plug-in terminal for 2.5 mm 2 wires Plug-in terminal with screws for 2.5 mm 2 wires 600 g 800 g 835 g By metal strips for panels between 1 and 5 mm POWER MONITORS - IN 96 & IN 144 69 * The analogue outputs add an error of 0.5 % of the FS, full scale. imension diagrams B im. (mm) A B C E recdigit NOUS recdigit POWER 89,5 135,8 126 92,5 96 144 8,2 9,2 92 x 92 138 x 138 A C Panel cut-out E

POWER MONITORS - RECIGIT NOUS recdigit NOUS POWER MONITORS - RECIGIT NOUS 70 The recdigit NOUS, in a compact housing 96 x 96, possesses all the necessary functions for supervising low-voltage network applications. Simplicity of use, design and high-level performance ensure perfect integration into your LV cabinets and panel switchboards. Universal Q Quality Measurement of all electrical parameters necessary for supervising a LV feeder. Connection on 1 A and 5 A current transformer with the same model. Measurement of TH-V, TH-I and calculation of I neutral to monitor the electrical supply quality (Nodus EQ). RS485 ModBus/JBus protocol for all supervision applications via computer or PLC. Metering in the 4 quadrants for cogeneration needs (Nodus EQ). Pulse output (programmable) or alarm (Nodus EQ). Reduced depth for integration into all types of LV cabinets. isplay New! 230/400 V direct network connection. LV network connection > 500 V via voltage ratio (690/100 for example). User-friendly Simultaneous display of four parameters with units. Automatic setting of display ranges and units (W, kw, var, kvar ). High-readability LC display. Back-lit on Nodus EQ. 4 direct-access keys to select the parameter to be displayed. Programmation (CT ratio, voltage ratio, digital link, ) very simple by scrolling menus available in French, German, English and Spanish. High-performance 32 parameters displayable (22 on Nodus E) and 98 parameters measured (75 on Nodus E), accessible using the RS485 link. Metrological characteristics: class 0.5 for measurement, class 1 for metering (IEC 61036). etection of phase-order misconnection, CT secondary inversion. Compliance with EN 50081-2, EN 50082-2, IEC 61010 standards ocumentation 906.111..111.725

POWER MONITORS - RECIGIT NOUS Front face : simplicity and readability direction : consummed or generated (NOUS EQ) Composite voltages Calculated I neutral (NOUS EQ) Global harmonic distorsion on V and I (NOUS EQ) JBus address of the power monitor RS485 in use irect access to measurement 4 lines of characters and a large number of pictograms accessible using the 4 front keys. Phase-order misconnection Max. values display Units automatic display Function of the 4 keys in programme mode POWER MONITORS - RECIGIT NOUS isplay 1 I1 (A) I2 (A) I3 (A) U1-2 (V) isplay 3 U1-2 (V) U2-3 (V) U3-1 (V) Frequency (Hz) isplay 2 I1max (A) I2max (A) I3max (A) Max total active power (kw) isplay 4 V1-N (V) V2-N (V) V3-N (V) Frequency (Hz) 71 isplay 5 Total active power (kw) Total reactive power (kvar) Power factor Total active energy (kwh) isplay 6 Total active power (kw) Total reactive power (kvar) Power factor Total reactive energy (kvarh) isplay 7 Total apparent power (kva) Total reactive power (kvar) Power factor Total apparent energy (kvah) isplay 8 Neutral current (A) Voltage TH (%) Current TH (%) Hour meter (1, 1/10, 1/100) isplay 9 CT x voltage ratio Transmission rate (bds) ModBus/JBus adress Machine serial number Product codes Model Auxilliary supply Reference recdigit NOUS E 230/400 Vac NO 1001 recdigit NOUS E 110/127/230 Vac NO 1002 recdigit NOUS E 125/220 Vdc NO 1003 recdigit NOUS E 24/110 Vdc NO 1004 recdigit NOUS EQ 110/127/230/400 Vac NOQ 2001 recdigit NOUS EQ 24/48/110 Vdc NOQ 2002 recdigit NOUS EQ 125/220 Vdc NOQ 2003 WINTHOR software Supervision and remote reading software for use with recdigit NOUS (see page 74) Reference in GREEN : product in stock ocumentation 906.111..111.725

POWER MONITORS - recdigit POWER recdigit POWER POWER MONITORS - recdigit POWER isplay recdigit POWER - isplay isplaying Measurement of parameters of main or sub-electrical panel switchboard. metering (active, reactive, apparent) in the two quadrants. The recdigit POWER displays up to 35 electrical parameters for LV, MV or HV networks, on three high-readability LE displays. Only three models for all types of applications : displaying, monitoring and energy managing. The recdigit POWER can be connected to any system (PC, PLC ) by using the analogue outputs, the pulse outputs or the digital link (RS485 ModBus/JBus ). The recdigit POWER line is achieved with 3 models. Main points High level metrological characteristics (measurement class 0.2; metering class 1 according to IEC 61036). 72 Q Quality M Management recdigit POWER - Quality Supervision, Supply quality Similar functions as previous, plus: 4-quadrants energy metering Monitoring of the supply quality; TH-V and TH-I on each phase. ating and recording of overthresholds on U, I, P and cos. Equipped in standard with an RS485 digital link (protocol ModBus/JBus RTU mode). recdigit POWER - Management management Similar functions as previous, plus: RS232 link socket on front face for a local reading on a personal computer. Recording of load curves in active and reactive power for energy management (submetering, optimisation, billing ). isplays 35 electrical parameters, as instantaneous, maximum and average values. Automatic setting of display. Alarm relay, metering-pulse outputs in standard. igital link RS485 protocol ModBus/JBus with a memory size designed for optimal integration in any supervision system. ocumentation 906.111..111.726

POWER MONITORS - recdigit POWER Sesame Software For Quality and Management models Product codes Model New! esignation Multi-display Reference isplay recdigit POWER -2-400-5-0 POW 1001 isplay recdigit POWER -2-100-5-0 POW 1002 isplay recdigit POWER -2-100-1-0 POW 1003 Quality recdigit POWER Q-2-400-5-0 POWQ 1001 Quality recdigit POWER Q-2-100-5-0 POWQ 1002 Quality recdigit POWER Q-2-100-1-0 POWQ 1003 Management recdigit POWER M-2-400-5-0 POWM 1001 Management recdigit POWER M-2-100-5-0 POWM 1002 Management recdigit POWER M-2-100-1-0 POWM 1003 Sesame Configuration software LOGG 2001 WinThor Software for supervising and remote-reading the recdigit POWER measurement systems (see page 74) Configuration and programming ate, hour, VT and CT ratios, synchronisation, thresholds and alarms delays, analogue outputs Reset of meters, min. and max. values, stream-recorded isplaying instantaneous, average and maximum values ; over-thresholds ; energy meters. How to order recdigit POWER Model - isplay Q - Quality M - Management Auxiliary supply 1-20 90 Vdc / 20 70 Vac 2-90 360 Vdc / 70 260 Vac* 3-190 460 Vac * Standard value Options 1-2 pulse outputs 2-2 analogue outputs 3-2 pulse outputs+ 2 analogue outputs 4-4 pulse outputs Input I 1-1 A 5-5 A Input U 100-100 V 400-400 V POWER MONITORS - recdigit POWER 73 Additional S Screen recisplay - Additional Screen The recisplay Additional Screen is a programmable multi-display unit for switchboards, that indicates up to 6 parameters issued for one or more instruments communicating using ModBus/JBus protocol, RTU mode. ENERIS V A kw Additional S Screen The recisplay incorporates 2 digital RS485 links : one is used for connecting the master apparatus, the second for connecting to the main ModBus/JBus networks.. The recisplay is invisible for the JBus network, so the superviser can communicate directly with the master apparatus connected to it. Rpm C C SELECT ENTER PROG Product codes Model Auxiliary supply Reference recisplay 110/220 Vac or Vdc REI 2000 recisplay 24/48 Vac or Vdc REI 2100 Reference in GREEN : product in stock

supervision & Management software - WINTHOR WinThor WinThor is a remote-reading, energy management software designed for use with our recdigit measurement systems, our CT remote-operated electronic meters, as well as the CCT pulse receiver. Two versions exist to meet your needs: the TELE 2000 module and the GEST 2000 module for system configuration and recorded parameter display. As a plus, the GEST 2000 module is equipped with an Analysis menu for energy consumption. TELE 2000 Remote meter-reading pack for remote data transmission. WINTHOR SOFTWARE 74 GEST 2000 Same functionalities plus: recording of load curves breakdown of consumption tariff simulation Technical specifications: Configuration menu GEST 2000 TELE 2000 Automatic configuration of communication parameters Creation of virtual meter (addition or subtraction of several measurement points) Programming of automatic remote-metering sessions of meter indices Programming of automatic remote-metering sessions of load curves Programming of automatic remote-metering sessions of overshoots and extremes efinition of your tariff contracts (pricing and subscribed power) isplay menu GEST 2000 TELE 2000 isplay of instantaneous and mean values per phase and overall isplay of minimum and maximum values* isplay of stream-recording of the active and reactive power values* isplay of indices from the meters (per phase, time slots...)* Recording of the values of your choice in curve and/or file form isplay of pages entirely configured by the user Monitoring of trends in energy consumption* Remote action on an overload relay (power cut-off) Programming of overload thresholds isplay of alarm status * data available on certain products Menu Analysis (see opposite) GEST 2000 only

supervision & Management software - WINTHOR ANALYSIS menu (GEST 2000 only) This menu enables you to carry out : - quantitative and qualitative ANALYSIS of your energy consumption in several forms (tables, graphs ) ; - optimisation of your consumption with the help of programmable tariff simulations. It contains three sections : 1 Table Stream-recorded table of power values per month. irect exportation of the values in a format compatible with the principal spreadsheets. 2 Graph Curve of overall consumption or consumption according to tariff range, in the year, month, week and day (peak periods). Simultaneous display of the load curve and the tariff contract selected (subscribed power, tariff periods ). WINTHOR SOFTWARE 3 Report & Evaluation Calculation of energy consumption per tariff entry and in total for a period of your choice. Sum of subscribed power overruns per tariff entry and in total. Evaluation of the real cost of energy depending on the tariff contract selected. irect exportation of the tables in a format compatible with the principal spreadsheets for printing out the energy bill. 75 Product codes Software Reference WinThor «Configuration & isplay» menus, in French TELE 2000 WinThor «Configuration, isplay, & Analysis» menus, in French GEST 2000 WinThor «Configuration & isplay» menus, in English TELE 2001 WinThor «Configuration, isplay & Analysis» menus, in English GEST 2001 Accessories CTA Self-contained desktop RS232/RS485 converter ACCJ 0006 CTB esktop RS232/RS485 converter (230Vac) ACCJ 00 A 8522 Industrial RS232/2xRS485 converter (230Vac) ACCJ 0002 INFINLINK Industrial RS232/4xRS485 converter (115/230Vac) ACCJ 1001 AMP-RS 485 RS/485/RS485 Repeater, power supply: 24 Vdc ACCJ 1002 Alim AMP Power supply: 230 Vac/24Vdc ACCJ 1003 Modem US Robotics Sporsters Voice Model 56 kbd MOV 2000 Configuration required - Pentium type PC - 16 Mb RAM minimum - 200 Mb hard disk minimum - 1024 x 768 graphic board - Windows 3.1, 95, 98, or NT - Serial port for communication - Parallel port for printing Code in GREEN : product in stock ocumentation 906.111..111.727

CT TOPTEM TERMINAL E GESTION CT Monitoring power in electrical networks Legend: Monitoring network Power monitor type recdigit POWER, recdigit NOUS, CT electronic meters CCT pulses receiver Monitoring power in electrical networks EXTRA HV/HV P. supplied XHV HV/MV SUBSTATION Cogeneration Monitoring station RS485 ModBus / JBus Feeder 1 M.V. Loops M.V. ata Bus Feeder 2 Main supply meter Prismeter 2 76 kwh kwh P. consumed Heating Machines etc. Lighting Monitoring station General services POWER STATION CONSUMER Power monitors can be used across all the stages in an electrical network, whether in production, transportation, distribution. There are various formats available and, depending on the application, some come with or without a display and are specifically adapted to the needs of high, medium or low voltage networks.