Electrical measurement and control M.5. CVM Power analyzers
|
|
|
- Dwain Chambers
- 10 years ago
- Views:
Transcription
1 Electrical measurement and control M.5 CVM Power analyzers
2 M.5 CVM Power analyzers M.5 - CVM Power analyzers CVMk2 Three-phase power analyzer(balanced and unbalanced) for panel or DIN rail mounting M5-8 CVM NRG 96 Three-phase power analyzer(balanced and unbalanced) for panel mounting M5-14 CVM MINI Three-phase power analyzer(balanced and unbalanced) for DIN rail mounting M5-16 CVM 96 Three-phase power analyzer(balanced and unbalanced) for panel mounting M5-18 CVM 96 Three-phase power analyzer(balanced and unbalanced) for panel mounting M5-19 CVM 144 Three-phase power analyzer(balanced and unbalanced) for panel mounting M5-20 CVM BD Three-phase power analyzer(balanced and unbalanced) for DIN rail mounting M5-23 CVM BDM Three-phase power analyzer(balanced and unbalanced) for DIN rail mounting, with internal 1 MB memory M5-25 Power Net Three-phase power M5-27 analyzer M5-27 TR8 Multi-channel DC voltage and current analyzer M5-29 Accesories M5-31 M5-2
3 CVM Power analyzers M.5 CVM Power analyzers Nowadays, companies, industries or any consumer of electrical energy are trying to optimise costs to become the most competitive players in the market. We can act over a large number of parameters to save on costs, such as on the consumption of electrical energy. CIRCUTOR's analyzers offer state-ofthe-art technology, measuring a large variety of electrical parameters, with the main purpose of controlling and managing an installation, machine, industry, etc. thus optimising the energy costs. M.5 Definition The CVM series of analyzers includes highly accurate metering stations that are aimed at the control and supervision of the main electrical parameters in three or four-wire, low and high voltage, single and/or three-phase grids. In addition, they offer the most innovative technologies and offer metering in true root mean square. Its indirect current outputs use ITF technologies in the.../5 A secondary or.../1 A secondary: galvanic insulation protection inputs What functions do CIRCUTOR's analyzers offer? They display and transmit all electrical parameters metered and/or calculated. They incorporate the metering function, storing in the memory the value of energy consumed and generated, even in the absence of an auxiliary power supply. Hourly discriminator with previous programming mode, thus obtaining a totalizer of active, apparent, reactive inductive and reactive capacitive energy, for each rate programmed (depending on the type).they incorporate the maximeter function, calculating the demand integrated in a programmable period (depending on the type). The integration is carried out with a sliding window and it can be carried out over the following adjustable parameters: three-phase current, active three-phase power, apparent threephase power or current per phase. Some of CIRCUTOR's analyzers can be expanded or offer modular capabilities, with additional functions that can be associated to any electrical parameter monitored or calculated, such as: ymulti-converter functions: analogue inputs and outputs. Alarm station or impulse generation function: digital inputs and outputs. The communications outputs, connection topologies and network protocols can be of different types. M5-3
4 M.5 CVM Power analyzers CVMk2 modules CVMk2 yconnections: Ethernet, RS-232, RS-485, Radio yprotocols: TCP, RTU, Profibus DP, Metasys N2 and XML. INTEGRATION OF COMMUNICA- TIONS IN ANALYZERS RS-485 communications can be used to make the most out of CIRCUTOR's analyzers with the management software, reading all parameters metered and calculated in real time. The PowerStudio Scada software not only displays the electrical parameters in real time, but it also generates a database in the PC, where it stores the log of values, which can be studied later on. CIRCUTOR offers a range of analyzers, which have Ethernet communications, so they can be connected directly to the intranet and Internet. Therefore, their integration with the PowerStudio software is quick and easy. In addition, CIRCUTOR offers Profibus analyzers, which can access a large variety of industrial automation applications, where the protocol is commonly used. Integration systems ( RTU vs. TCP) Until now, CIRCUTOR offered and is currently offering Ethernet communication gateways, ( RTU), (TCP2RS code M54031), used for the integration of RS-485 equipment, making use of the Ethernet infrastructures existing in installations. Said gateways were designed for the communication with market SCADAs that did not have the possibility of establishing IP addressing communications, since this was through a virtual port redirectioning software. Another problem with this type of communications was that it was a mono-master system, i.e., communications could only be established with slave equipment, with a single master or control PC. Communications could not be established with other equipment that was not established as a slave. Fortunately, PLC data acquisition systems and other market masters, as well as the slaves commonly installed in these cases (three-phase power quality analyzers) have been unified under a standardised protocol that is very popular among manufacturers: Industrial Ethernet or /TCP.The implementation of this system has led to the standardisation of the protocol so that any slave can be queried by various masters at the same time (up to eight), thus multiplying the different and diverse communication topologies in an energy control installation or in any process control situation (multi-master cases).therefore, CIRCU- TOR has launched its range of Ethernet analyzers again, implementing the new protocol with the main purpose of standardising the communication methods used by most of the global manufacturers. CVMk2-ITF + k2-exp-sd-modbus/ TCP: Power Quality AnalyzerM54400 / M Ethernet expanding module (/TCP) M54504 CVM144-ITF-Ethernet-TCP: Power Quality Analyzer (/TCP): M50790 CVM96-ITF-Ethernet-TCP: Power Quality Analyzer (/TCP): M51241 TCP2RS: Converter RS232-RS485 / Ethernet (/TCP): M54032 LM50-TCP: Alarm / Impulse Centralizer (/TCP): M54032 With this type of analyzers, the integration of CIRCUTOR's units with any market SCADA, PLC or control master is easier and simpler than ever. ENERGY MANAGEMENT SOFTWARE: Power Studio Scada Toph-pherformance management software designed for the analysis of the consumption of energy and other parameters metered by CIRCUTOR's equipment. What can this software be used for? Control of the energy in an installation, analysing the status of its lines and installations in real time. M5-4
5 CVM Power analyzers M.5 Simulation of receipts, depending on the version. It can be used to analyse the consumption of energy in the installations with the equipment supplied by CIRCU- TOR and it also enables the simulation of bills, defining different rates, whether they are regulated or not. Study of the evolution of electrical parameters in time, such as: V, A, kw, etc, with graphs and tables. Data and graphs can be exported to draw up reports. Different analyzers can be used to analyse and study the quality parameters defined by the IEC Standard. Applications Supervision and preventive maintenance of an installation, with the real-time and log of the status and consumption of all sorts of low and medium voltage (LV and MV) machines and installations. M5-5
6 M.5 CVM Power analyzers Product selection table CVMk2 CVM NRG96 CVM MINI CVM 96 METERING FEATURES L1 L2 L3 N III L1 L2 L3 III L1 L2 L3 III L1 L2 L3 III Single phase voltage * * * * * * * * * * * * * Phase-phase voltage * * * * * * * * * * * * Vref (GND)-NEUTRAL * Current * * * * * * * ** * * * * * * * ** Frequency * * * * Active power * * * * * * * * * * * * * * * * Reactive power L * * * * * * * * * * * * ** ** ** * Reactive power C * * * * * * * * * * * * ** ** ** ** Apparent power * * * * * * * * * * Power factor * * * * * * * * * * * * * * * Cos j * * * * * * ** Maximum active power demand * * * * Maximum apparent power demand * * * * Maximum current demand * * * * * * * * * * Neutral current * * * * THD * * * * * * * * * * * * * THD Current * * * * * * * * * * * * * harmonics (depending on * * * * 50 * * * 15 * * * 15 the type (*) Current harmonics (depending on * * * * 50 * * * 15 * * 15 ** ** ** 31 the type (*) Active energy * * * * Reactive energy L * * * * Reactive energy C * * * * Apparent energy * * * * Flicker (WA and PST) * * * Factor K (current) * * * Peak factor (voltage) * * * Unbalance (voltage and current) * * * Asymmetry (voltage and current) * * * Rates (depending on the type) Analogue inputs (0/ ma) * Analogue outputs (0/ ma) * Digital inputs * Digital outputs * * * * COMMUNICATIONS FEATURES RS-232 RS-485 * * * * Ethernet * * COMMUNICATIONS PROTOCOL RTU * * * * TCP * * Profibus DP Johnson Controls * Compatible with PowerStudio SCADA PAGE Possible parameters, depending on the unit selected. *Available for display and communications. **Available only for communications. (*)Harmonic decomposition in HAR types. M5-6
7 CVM Power analyzers M.5 CVM 144 CVM BD CVM BDM Power Net L1 L2 L3 III L1 L2 L3 III L1 L2 L3 III L1 L2 L3 III METERING FEATURES * * * * * * * * * * * * Single phase voltage * * * * * * * * * * * * Phase-phase voltage Vref (GND)-NEUTRAL * * * ** * * * * * * * * * * * * Current * * * * Frequency * * * * * * * * * * * * * * * * Active power * * * * * * * * * * * * * Reactive power L * * * * * * * * * * * * * Reactive power C ** * * * Apparent power * * * * * * * * * * * * * * * * Power factor ** * Cos j * * * * Maximum active power demand * * * * Maximum apparent power demand * * * * * Maximum current demand * * Neutral current * * * * * * * * * * * * THD * * * * * * * * * * * * THD Current ** ** ** 15 harmonics (depending on the type (*) * * * 31 ** ** ** 15 Current harmonics (depending on the type (*) * * * * Active energy * * * * Reactive energy L * * * * Reactive energy C ** * Apparent energy * * * Flicker (WA and PST) Factor K (current) Peak factor (voltage) Unbalance (voltage and current) Asymmetry (voltage and current) Rates (depending on the type) * Analogue inputs (0/ ma) * * * Analogue outputs (0/ ma) * Digital inputs * * * Digital outputs COMMUNICATIONS FEATURES * * * * RS-232 * * * * RS-485 * Ethernet COMMUNICATIONS PROTOCOL * * * RTU * TCP * Profibus DP * * Johnson Controls * * Compatible with PowerStudio SCADA PAGE Possible parameters, depending on the unit selected. *Available for display and communications. **Available only for communications. (*)Harmonic decomposition in HAR types. M5-7
8 M.5 CVM Power analyzers CVMk2 Three-phase power analyzer(balanced and unbalanced) for panel or DIN rail mounting Description Three-phase power analyzer (balanced and unbalanced) for its assembly on panel or DIN rail mounting with a graphical display. measuring in 4 quadrants. Other features include: Class 0.2 or 0.5 power and energy Measuring of Class B supply quality events (guaranteeing the power supply of the unit with an UPS, battery, etc.) Current measuring.../5 or.../1 A Measure of neutral current with transformer Optional energy consumption and generation billing (up to 9 rates) RS-485 /RTU Communications Expansion possibilities (up to 3 modules) Backlit VGA graphical display Instantaneous display of maximum and minimum electrical parameters with date and hour Measure of energy consumed and generated, up to 100 GW h Universal series power supply With ITF technology: galvanic insulation protection inputs Application Applied to the control of general switchboards and low, medium and high voltage connection points Alarm station with voltage-free digital inputs Submetering station: impulse meter with other types of consumption, such as gas, water, steam, etc. with their digital inputs Measuring converter: optional association of an instantaneous parameter to one of the analogue outputs available ( ma / ma) Instantaneous, maximum and minimum parameter recording unit, with date and hour and an expandable memory card Power quality analyzer: harmonic decomposition up to order 50º, asymmetries, flicker, unbalances, overvoltages, gaps, interruptions, etc. Power supply circuit V ac / V dc ac Power supply frequency Hz ac Power supply consumption 30 V A dc Power supply consumption < 25 W Metering circuit Nominal voltage 300/500 V ph-n / V ph-ph or 500/866 V ph-n / V ph-ph Frequency Hz Metering margin % of the U n for U n = 300 V ac (ph-n) % of the U n for U n = 500 V ac (ph-n) Maximum metering voltage 360 V ac Admissible overvoltage 750 V ac Maximum consumption (limited current) < 0.6 V A Current measuring circuit Nominal current.../5 A or.../1 A Metering margin % of I n for I n = 5 A Primary current metered Programmable <30,000 A Admissible overload 6 A permanent, 100 A t < 1 s Consumption < 0.45 V A Maximum meter value 100 GW h Class/Accuracy 0.2 or 0.5 power and energy Ambient conditions Operating temperature ºC Relative humidity % Build features Metering module Assembly on DIN Rail (EN 50022) Screen or screen + metering module Assembly on panel (96 x 96 mm, 144 x 144 mm) or opening with a 103 mm diameter External dimensions 144 x 144 x 116 mm Safety Designed for CAT III 300/520 Vac installations, in accordance with EN Double-insulated electric shock protection, class II Standards IEC , IEC , IEC , IEC , IEC M5-8
9 CVM Power analyzers M.5 CVMk2 Three-phase power analyzer(balanced and unbalanced) for panel or DIN rail mounting References Compact units (metering + display module) Quadrants Class Communications MODBUS / RTUProtocol Neutral current Universal power supply Type 4 0,5 RS-485 Yes Yes CVMk2-ITF-405 M ,5 RS-485 Yes Yes CVMk2-ITF-402 M54402 Measuring units (measuring module) Quadrants Class Communications MODBUS / RTUProtocol Neutral current Universal power supply Type 4 0,5 RS-485 Yes Yes M-CVMk2-ITF-405 M ,5 RS-485 Yes Yes M-CVMk2-ITF-402 M54412 Connections Connection of 4 Current transformers (5 wires) Connection of 4 Current transformers and 2 voltage transformers Connection of 3 Current transformers (3 wires) Dimensions Fig. 1 Fig. 2 Fig. 3 Figures 1, 2 and 3: Display of the frontal panel part embedding (display) in a 92 x 92 mm opening, with a diameter of 110 mm and 138 x 138 mm, respectively M5-9
10 M.5 CVM Power analyzers Exchangeable modules CVM k2 1. k2-exp-8i / 8O-Digital-TR Card Card with 8 digital inputs and 8 digital outputs. Outputs with optocoupled transistor Connection Logical inputs Type of input Type of coupling V max minimum t ON / t OFF -free Optoinsulated 24 V dc t ON 40 ms t OFF 40 ms Static outputs AC Non-repetitive Peak voltage Nominal current Repetitive current during t=1s Maximum current t=10 ms <100 Vac 350 V pk. 100 ma 120 ma 350 ma Connection Rigid conductor section mm 2 M k2-exp-8i / 4O-Analogue Card Card with 8 digital inputs and 4 digital outputs Connection Analogue outputs Maximum internal voltage Output range 20 / 24 Vdc 0 / ma Linearity 1 % Load resistance Output range < 500 ohm 4000 points Analogue inputs Type of metering - Input range 0 / ma Metering accuracy 1 % Input impedance 200 ohm Connection Rigid conductor section mm 2 M54502 M5-10
11 CVM Power analyzers M.5 Exchangeable modules CVM k2 3. k2-exp-8i / 4O-Digital-RL Card Card with 8 digital inputs and 4 digital outputs. Outputs with relay. Connection Logical inputs Type of input Type of coupling V max minimum t ON / t OFF Relay outputs AC AC Current Minimum relay load Mechanical working life Electrical working life Connection -free Optoinsulated 24 Vdc t ON 40 ms t OFF 40 ms 250 Vac 6 Aac 1 Vac Aac 5 x 10 6 operations NO: 5x10 4, NC: 3x10 4 cycles Rigid conductor section mm 2 M k2-exp-sd-modbus/tcp Card Ethernet communications card and SD memory Ethernet output Network Protocol Communication protocol Speed SD Card Type of card Maximum capacity Ethernet RJ-45 / TCP compatible with 10 base T / 100 base Tx SD 2 Gb Format FAT 16 M54504 Icons Recommendations xthe unit is formatted automatically when installing an SD card. Do not install cards with contents stored that you wish to keep. xto remove the SD card safely, interrupt the communications between the unit and the memory. There are two ways to do so; either turning the unit off or accessing the card setup menu. xcorrect SD memory state xincorrect SD memory state xsd Card removal enabled M5-11
12 M.5 CVM Power analyzers Exchangeable modules CVM k2 5. PROFIBUS Card GSD Modules The GSD modules are configured in accordance with the following table. The table shows the module number, content (variables) and the total size of the module. Mod. Parameters Byte Size Simple voltages 12 1 Phase currents 12 Compound voltages 12 Power factor 12 Frequency Power ratings Mean values 12 Neutral values 8 Three-phase values Current energy with no billing THD U / I THD odd / even Unbal / Asymmetry / Flicker Odd harmonics, (15º) Even harmonics, Current (15º) Digital I. 1 / Analogue I Digital I. 2 / Analogue I Digital I. 3 / Analogue I Cos φ M5450A 6. Exp. Card 4 S analogue + 4 S static. ±5 ma Logical outputs Output range ±5 ma Linearity 1 % Load resistance < 1000 Output range 4000 points Static outputs <100 Vac/Vdc Non-repetitive Peak voltage 350 V pk. Nominal current 100 ma Repetitive current during t=1s 120 ma Maximum current t=10 ms 350 ma Connection Rigid conductor section mm 2 M54507 Connection M5-12
13 CVM Power analyzers M.5 Exchangeable modules CVM k2 7. k2-exp-sd Card Ethernet communications card and SD memory SD Card Type of card Maximum capacity SD 2 Gb Format FAT 16 M54506 Icons xcorrect SD memory state Recommendations Card used to record up to 400 electrical variables coming from a CVMk2 power quality analyzer. It also includes a log of the quality events: overvoltages, voltage interruptions or gaps. xincorrect SD memory state xsd Card removal enabled M5-13
14 M.5 CVM Power analyzers CVM NRG 96 Three-phase power analyzer(balanced and unbalanced) for panel mounting Description Three-phase power analyzer(balanced and unbalanced) for its assembly on panels with a minimum depth, measuring in 4 quadrants. Other features include:class 0.5 energy Current measure.../5 RS-485 /RTU Communications, depending on the type Instantaneous, maximum and minimum parameter display Digital output with optoinsulated transistor ITF Technology: Galvanic insulation protection inputs inputs, depending on the type Maximeter function (A / A III / kw III / kv A III) Default page selection Universal power supply for Plus types Application Applied to the control of switchboards and low and medium voltage connection points. Alarm control, with full programming of the variable controlled, maximum and minimum values and the delay Control of active or reactive energy with pulses Control of instantaneous, maximum and minimum values of the electrical parameters metered Power supply circuit dc Version Plus Version: ac and dc 24 Vdc ( %) V ac / V dc AC Power supply frequency Hz (ac type) Maximum consumption (equipment with communications) 2.2 W 2 V A DC Power supply consumption (equipment w/o communications) 1.8 W 2 V A Metering circuit Nominal voltage 300 Vac (ph-n) / 520 Vac (ph-ph) Frequency Hz Nominal current I n.../ 5 A Current consumption of the circuit 0.75 V A Overload (permanent) 1.1 I n Class/Accuracy 0.5 % ± 2 digits Current 0.5 % ± 2 digits Power rating 1 % ± 2 digits Ambient conditions Operating temperature ºC Relative humidity % Output transistor Optoinsulated (collector open) NPN Maximum switching voltage 24 Vdc Maximum switching current 50 ma Maximum impulse frequency 5 impulse / s Duration of the impulse 100 ms Build features Type of box VO self-extinguishing plastic Degree of protection Dimensions Safety Fitted unit (frontal): IP 51 Non-fitted unit (sides and rear cover): IP x 96 x 63 mm Designed for CAT III 300/520 Vac installations, in accordance with EN Double-insulated electric shock protection, class II Standards IEC 664, VDE 0110, UL 94, IEC 801, IEC 348, IEC 571-1, EN , EN , EN M5-14
15 CVM Power analyzers M.5 CVM NRG 96 Three-phase power analyzer(balanced and unbalanced) for panel mounting References Quadrants Class (V, A) Communications MODBUS / RTUProtocol Digital output Universal power supply Harmonics Type 4 0,5 - - Yes - CVM-NRG 96 M ,5 - - Yes - CVM-NRG 96-ITF M ,5 RS Yes - CVM-NRG 96-ITF, RS485 C M ,5 RS Yes U and I (15º) CVM-NRG 96-ITF-HAR, RS485 C M51B11 CVM NRG96-MC, Sistemas de medida Eficiente 4 0,5 - - Si - CVM NRG96-MC-ITF M ,5 RS Si - CVM NRG96-MC-ITF-RS485-C2 M52081 Transformadores Eficientes monofásicos MC1 y trifásicos MC3, Serie MC Max. A Ranges Class 0,5 Power Measurement Internal diameter Type 63-0,1 VA 3 Phases 7,1 mm MC3-63 M ,1 VA 3 Phases 14,6 mm MC3-125 M /200/250 0,25 VA 1 Phase 20 mm MC /200/250 M /400/500 0,25 VA 1 Phase 30 mm MC /400/500 M73114 Coding table Dimensions M 5 X X X X 0 0 X Power Supply (PSV) Internal Standard (230 Vac) Vac Vdc A Vdc 5 Connections CVM NRG96, 3 or 4 wires (low voltage) CVM NRG96, 3 wires (2 transformers and 3 Current transformers) CVM NRG96, 3 wires (2 transformers and 2 Current transformers) V aux. V aux. V aux. M5-15
16 M.5 CVM Power analyzers CVM MINI Three-phase power analyzer(balanced and unbalanced) for DIN rail mounting Description Three-phase power analyzer(balanced and unbalanced) for its assembly on DIN rails with very small dimensions, measuring in 4 quadrants. Other features include: Current measuring.../5 or.../1 A DIN rail format with only 3 modules Assembly on the 72 x 72 mm panel with frontal adaptor (cod. M5ZZF1) RS-485 Communications (-RTU) Two transistor outputs ITF technology: galvanic insulation protection inputs inputs, depending on the type Selection of parameters displayed Default page selection Universal power supply for the Plus type Sealable Application Application for the control of switchboards and low and medium voltage connection points, where an analyzer must be installed on the DIN rail due to space restrictions. Control of instantaneous, maximum and minimum values of the electrical parameters metered. Power supply circuit Consumption Frequency 230 V ac ( %) Plus: V ac / V dc 3 V A Hz Metering circuit Nominal voltage 300 V ac (ph-n) / 520 Vac (ph-ph) Frequency Hz consumption of the circuit 0.7 V A Current consumption of the circuit ITF 0.9 / Shunt 0.75 V A Overload (permanent) 1.2 I n Class/Accuracy 0.5 % ± 1 digit Current 0.5 % ± 1 digit Power rating 1 % ± 1 digit Ambient conditions Operating temperature ºC Relative humidity (non-condensing) % Output transistor Optoinsulated (collector open) NPN Maximum switching voltage 24 V dc Maximum switching current 50 ma Maximum impulse frequency 5 impulse / s Duration of the impulse 100 ms Build features Type of box VO self-extinguishing plastic Degree of protection Dimensions Weight Safety Embedded equipment: IP 41 Terminals: IP x 85 x 67.9 mm (3 modules) 210 g Designed for CAT III 300/520 Vac installations, in accordance with EN Double-insulated electric shock protection, class II Standards IEC 664, VDE 0110, UL 94, IEC 801, IEC 348, IEC 571-1, EN , EN , EN M5-16
17 V aux. V aux. V aux. CVM Power analyzers M.5 CVM MINI Three-phase power analyzer(balanced and unbalanced) for DIN rail mounting References Digital Quadrants Class (V, A) Communications Protocol output Harmonics Type 4 0, CVM-MINI M , CVM-MINI-ITF M ,5 RS-485 MODBUS 2 - CVM-MINI-ITF-RS485-C2 M ,5 RS-485 MODBUS 2 V and I (15º) CVM-MINI-ITF-HAR-RS485-C2 M52031 CVM MINI-MC, Efficient measuring Systems 4 0,5 - - Si - CVM MINI-MC-ITF M ,5 RS Si - CVM MINI-MC-ITF-RS485-C2 M52081 MC1 single-phase and MC3 three-phase Efficient Transformers, MC Series Max. A Ranges Class 0,5 Power Measurement Internal diameter Type 63-0,1 VA 3 phase 7,1 mm MC3-63 M ,1 VA 3 phase 14,6 mm MC3-125 M /200/250 0,25 VA 1 phase 20 mm MC /200/250 M /400/500 0,25 VA 1 phase 30 mm MC /400/500 M73114 Coding table Dimensions M 5 X X X X 0 0 X Power Supply (PSV) Internal Standard 230 Vac Vac Vdc C Connections CVM MINI, 3 or 4 wires (low voltage) CVM MINI, 3 wires (2 transformers and 3 Current transformers) CVM MINI, 3 wires (2 transformers and 3 Current transformers) M5-17
18 M.5 CVM Power analyzers CVM 96 Three-phase power analyzer(balanced and unbalanced) for panel mounting Description Three-phase power analyzer(balanced and unbalanced) for its assembly on 96 x 96 mm panels, measuring in 2 quadrants. Other features include: Current measuring.../5 Communication protocol: RTU, TCP, Johnson Controls Connections: RS-232, RS-485, Ethernet 2 relay outputs ITF Technology: galvanic insulation protection inputs inputs, depending on the type Maximeter function (A / A III / kw III / kv A III) Default page selection Metering ranges: 110, 520, 866 V f-f Detection of incorrect connections Application Applied to the control of switchboards and low and medium voltage connection points. Control of alarms; the variable controlled, maximum and minimum values and delay variables are fully programmable. Control of instantaneous values and storage of maximum and minimum values of the electrical parameters metered. Power supply circuit 230 Vac ( %). For other values, see the coding table Consumption 5 V A Frequency Hz Metering circuit Nominal voltage 300 V ac (ph-n) / 520 V ac (ph-ph) Frequency Hz Current consumption of the circuit 0.75 V A Nominal current... / 5 A Overload (permanent) 1.2 I n Class/Accuracy 0.5 % ± 2 digits Current 0.5 % ± 2 digits Power ratings 1 % ± 2 digits Type of output Relay Maximum switching voltage 250 V ac Maximum switching current 3 A Mechanical working life 3 x 10 7 operations Maximum impulse frequency 1 impulse / s Ambient conditions Operating temperature ºC Relative humidity (non-condensing) % Build features Type of box VO self-extinguishing plastic Fitted unit (frontal): IP 54 Degree of protection Non-fitted unit (sides and rear cover): IP 31 Dimensions 96 x 96 x 78 mm Weight 520 g. Safety Designed for CAT III 300/520 Vac installations, in accordance with EN Double-insulated electric shock protection, class II Standards IEC 664, VDE 0110, UL 94, IEC 801, IEC 348, IEC 571-1, EN , EN , EN M5-18
19 CVM Power analyzers M.5 CVM 96 Three-phase power analyzer(balanced and unbalanced) for panel mounting References Quadrants Class (V,A) Communications Protocol Relay output Harmonics Current neutral Type 2 0, CVM 96 M , CVM 96-ITF M ,5 RS CVM 96-ITF-RS485-C2 M ,5 Ethernet / TCP CVM 96-ITF-Ethernet-C2 M ,5 RS-485 Johnson Controls CVM 96-ITF-Johnson-C2 M ,5 RS A (31º) Yes CVM 96-F- ITF-RS485-C2-HAR-IN M51513 Coding table Dimensions M 5 X X X X 0 0 X X X Power Supply (PSV) metered (VM) Current input (CI) Internal Standard (230 V ac) V ac V ac V ac V dc 5 Standard (300 V ph-n / 520 V ph-ph ) V ph-n / 110 V ph-ph V ph-n / 866 V ph-ph 3 Standard (.../ 5 A) 0.../ 1 A (Only ITF) 1 Window: x mm Connections V aux. V aux. See the user manual for other types of connections M5-19
20 M.5 CVM Power analyzers CVM 144 Three-phase power analyzer(balanced and unbalanced) for panel mounting Description Three-phase power analyzer(balanced and unbalanced) for its assembly on 144 x 144 mm panels, measuring in 2 quadrants. Other features include: Current measuring.../5 A Communication protocol: RTU, TCP, Johnson Controls Connections: RS-232, RS-485, Ethernet. Expandable input / output modules ITF Technology: galvanic insulation protection inputs inputs, depending on the type. Maximeter function (A / A III / kw III / kv A III). Default page selection Varied measuring ranges (110, 520, 866 V ph-ph) Incorrect connection detection (LED flashing). Application Applied to the control of switchboards and low and medium voltage connection points Alarm station, fully programmable variables controlled, maximum value, minimum value and delay Control of instantaneous values, maximum and minimum values of the electrical parameters metered Multiple-converter function with its analogue outputs 0/4..20 ma Leakage current and neutral metering function Power supply circuit Consumption Frequency Metering circuit Nominal voltage Frequency Current consumption of the circuit Nominal current 230 Vac ( %). For other values, see the coding table 5 V A Hz 300 Vac (ph-n) / 520 Vac (ph-ph) Hz 0.75 V A... / 5 A Overload (permanent) 1.2 I n Class/Accuracy 0.5 % ± 2 digits Current 0.5 % ± 2 digits Power ratings 1 % ± 2 digits Type of output Relay Maximum switching voltage 250 V ac Maximum switching voltage 750 V A Maximum switching current 3 A Mechanical working life 3 x 10 7 operations Maximum impulse frequency 1 impulse / s Ambient conditions Operating temperature ºC Relative humidity (non-condensing) % Build features Type of box VO self-extinguishing plastic Degree of protection Dimensions Weight Fitted unit (frontal) Non-fitted unit (sides and rear cover) IP 54 IP x 144 x 76 mm 400 g Safety Designed for CAT III 300/520 Vac installations, in accordance with EN Double-insulated electric shock protection, class II Standards IEC 664, VDE 0110, UL 94, IEC 348, IEC 571-1, EN , EN , EN M5-20
21 CVM Power analyzers M.5 CVM 144 Three-phase power analyzer (balanced and unbalanced) for panel mounting References Quadrants Class (V,A) Communications Protocol Digital outputs Analogue outputs Digital inputs Analogue inputs Harmonics Current leakages / neutral Type EXPANDABLE EQUIPMENT 2 0, CVM 144 M , CVM 144-ITF M , A (31º) - CVM 144-ITF-HAR M50A60 2 0,5 Ethernet / TCP CVM 144-ITF-Ethernet-TCP M ,5 RS-485 Profibus DP CVM 144-ITF-Profibus M ,5 RS-485 Johnson Controls CVM 144-ITF-Johnson Controls M50C10 EXCHANGEABLE MODULES (for expandable equipment) Yes CVM 144-C2-Currents Module M RS RS RS RS CVM 144-RS485-C2 Module M Yes CVM 144-RS485-C2-Currents Module M CVM 144-RS485-C2-Digital Module M CVM 144-RS232-C2 Module M51020 COMPLETE EQUIPMENT 2 0,5 RS ,5 RS ,5 RS ,5 Ethernet 2 0,5 Ethernet / TCP / TCP CVM 144-ITF-RS485-C2 M CVM 144-ITF-RS485-C2-A4O M50A CVM 144-ITF-RS485-C2-A2I/2O M50A CVM 144-ITF-Ethernet-C2-A2I/2O-TCP M50A Yes CVM 144-ITF-Ethernet-C2-currents-TCP M ,5 RS-485 Profibus DP CVM 144-ITF-Profibus-C2-A2I/20 M50A38 2 0,5 RS-485 Profibus DP Yes CVM 144-ITF-Profibus-C2-Currents M ,5 RS-485 Johnson Controls Yes CVM 144-ITF-Johnson Controls-C2-currents M50C11 M5-21
22 M.5 CVM Power analyzers CVM 144 Three-phase power analyzer (balanced and unbalanced) for panel mounting Coding table Dimensions M 5 X X X X 0 0 X X X Power Supply (PSV) metered (VM) Current input (CI) Internal Standard (230 V ac) V ac V ac V ac V dc 5 Standard (300 V ph-n /520 V ph-ph ) V ph-n / 110 V ph-ph V ph-n / 866 V ph-ph 3 Standard (.../ 5 A) 0.../ 1 A (Only ITF) 1 Window: x mm Connections CVM 144 CVM 144 Three-phase networks - 4 wires (low voltage) Three-phase networks - 3 wires (low voltage) See the user manual for other types of connections M5-22
23 CVM Power analyzers M.5 CVM BD Three-phase power analyzer(balanced and unbalanced) for DIN rail mounting Description Three-phase electrical network analyzer (balanced and unbalanced) assembled on DIN rail, measuring in 4 quadrants (consumption and generation). Other features include: Current measuring.../5 or.../1 A Measuring of active (kw h) and reactive (kvarh) energy consumed and generated, both capacitive and inductive. (4 quadrants) 8 module DIN Rail format Adjustable dual kw / MW scale -RTU Communications protocol Optional second RS-485 port to connect I/O peripherals, depending on the type. ITF Technology: galvanic insulation protection inputs, depending on the type Selection of the parameters displayed Selection of the default page Internal clock used to program and classify the three hourly rates Application Application for the control of switchboards and low and medium voltage connection points, where an analyzer must be installed on the DIN rail Control of instantaneous, maximum and minimum values of the electrical parameters metered Alarm station of alarms with analogue signal Rate establishing control for up to three different rates Power supply circuit Consumption Frequency 230 V ac ( %) For other values, see the coding table 6 V A Hz Metering circuit Nominal voltage 500 V ac (ph-n) / 866 V ac (ph-ph) Frequency Hz Current consumption of the circuit 0.6 V A Nominal current... / 5 A Overload (permanent) 1.2 I n Class/Accuracy 0.5 % ± 2 digits Current 0.5 % ± 2 digits Power rating 1 % ± 2 digits Ambient conditions Operating temperature ºC Relative humidity (non-condensing) % Build features Type of box VO self-extinguishing plastic Degree of protection Dimensions Weight Safety Embedded equipment: IP 41 Terminals: IP x 110 x 70 mm (3 modules) 520 g Designed for CAT III 300/520 Vac installations, in accordance with EN Double-insulated electric shock protection, class II Standards IEC 664, VDE 0110, UL 94, IEC 801, IEC 348, IEC 571-1, EN , EN , EN M5-23
24 M.5 CVM Power analyzers CVM BD Three-phase power analyzer (balanced and unbalanced) for DIN rail mounting References Quadrants Class (V/A) Clock THD/D (V,A) Maximum demand MODBUS Communications RED Communications Relay output Output ma Type 4 0,5 Yes Yes Yes RS-485 RS CVM-BD-RED-H M ,5 Yes Yes Yes RS-485 RS CVM-BD-RED-C2-H M ,5 Yes Yes Yes CVM-BD H M ,5 Yes Yes Yes RS-485 RS CVM-BD-RED-C420-H M ,5 Yes Yes Yes RS-485 RS CVM-BD-RED-420-H M52123 Coding table Dimensions M 5 X X X X 0 0 X X X X X Power Supply (PSV) metered (VM) Current input (CI) Other (only CVM-BD- RED/ BDM) Internal Standard (230 Vac) Vac Vdc 5 Standard (300 V ph-n /520 V ph-ph ) 110 V ph-n / 190 V ph-ph V ph-n / 866 V ph-ph 3 Standard (.../ 5 A) 0.../ 1 A (Only ITF) 1 Standard 0 0 RS-232 Communications Connections Three-phase network (low voltage) 3 current transformers + 2 voltage transformers See the user manual for other types of connections M5-24
25 CVM Power analyzers M.5 CVM BDM Three-phase power analyzer(balanced and unbalanced) for DIN rail mounting, with internal 1 MB memory Description Three-phase power analyzer(balanced and unbalanced) for its assembly on DIN rails, with internal 1 MB memory, measuring in 4 quadrants. Other features include: Current measuring.../5 A Measuring of active (kw h) and reactive (kvarh) energy consumed and generated, both capacitive and inductive. (4 quadrants) 8 module DIN rail format Adjustable dual kw/mw scale Calculates the flicker per phase RS-485 communications with RTU and Zmodem protocol to download files Optional second RS-485 port to connect I/O peripherals ITF Technology: galvanic insulation protection inputs, depending on the type Default page selection Optional use of rates with RED or RED- MAX modules Application Application for the control of switchboards and low and medium voltage connection points, where an analyzer must be installed on the DIN rail Control of instantaneous, maximum and minimum values of the electrical parameters metered Applications where the analyzer's memory must store the electrical parameters measured. Power supply circuit Consumption Frequency 230 V ac ( %). For other values, see the coding table 6 V A Hz Metering circuit Nominal voltage 500 V ac (ph-n) / 866 V ac (ph-ph) Frequency Hz Current consumption of the circuit 0.6 V A Nominal current... / 5 A Overload (permanent) 1.2 I n Class/Accuracy 0.5 % ± 2 digits Current 0.5 % ± 2 digits Power rating 1 % ± 2 digits Internal memory 1 MB Ambient conditions Operating temperature ºC Relative humidity (non-condensing) % Build features Type of box VO self-extinguishing plastic Degree of protection Dimensions Weight Safety Embedded equipment: IP 41 Terminals: IP x 110 x 70 mm (3 modules) 520 g Designed for CAT III 300/520 Vac installations, in accordance with EN Double-insulated electric shock protection, class II Standards IEC 664, VDE 0110, UL 94, IEC 801, IEC 348, IEC 571-1, EN , EN , EN M5-25
26 M.5 CVM Power analyzers CVM BDM Three-phase power analyzer (balanced and unbalanced) for its assembly on DIN rails, with internal 1 MB memory References Quadrants Class (V,A) Clock THD/D (V,A) Maximum demand Flicker meter Harmonics meter MODBUS Communications Internal memory Relay output Output ma Type 4 0,5 Yes Yes Yes Yes Yes RS MB - - CVM-BDM M ,5 Yes Yes Yes Yes Yes RS MB 2 - CVM-BDM-C2 M ,5 Yes Yes Yes Yes Yes - 1 MB 1 1 CVM-BDM-C420 M ,5 Yes Yes Yes Yes Yes RS MB - 2 CVM-BDM-420 M52213 Coding table Dimensions M 5 X X X X 0 0 X X X X X Power Supply (PSV) Internal Standard (230 V ac) V ac Vdc 5 measurement (VM) Current input (CI) Other (only CVM-BD- RED/ BDM) Standard (300 V ph-n /520 0 V ph-ph ) 110 V ph-n / 190 V ph-ph V ph-n / 866 V ph-ph 3 Standard (.../ 5 A) 0.../ 1 A (Only ITF) 1 Standard 0 0 RS-232 Communications 0 1 Connections Three-phase network (low voltage) 3 current transformers + 2 voltage transformers M5-26
27 CVM Power analyzers M.5 Power Net Three-phase power analyzer Description Direct Current measuring, up to 1,000 A ac, depending on the type The measure points are composed of a PowerNet and 2 TC-PowerNet Application Control application in distribution panels and low and medium voltage connections, with the need to measure various points with compact units, with no need to install them on DIN rail or panel Control of instantaneous, maximum and minimum values of the electrical parameters measured. Power supply circuit 400 V ac ( %) between L1-L2 Frequency Hz Consumption 4.2 V A Metering circuit Nominal voltage 300 V ac (ph-n) / 520 V ac (ph-ph) Frequency Hz Nominal current Up to 1,000 A ac, depending on the model consumption of the circuit 0.75 V A Overload (permanent) 1.2 I n Class/Accuracy 0.5 % ± 2 digits Current 0.5 % ± 2 digits Power rating 1 % ± 2 digits Ambient conditions Operating temperature ºC Relative humidity % Build features Type of box VO self-extinguishing plastic Degree of protection IP 54 Dimensions 165 x 73 x 33 mm Weight 220 g Safety Designed for CAT III 300/520 Vac installations, in accordance with EN Double-insulated electric shock protection, class II Standards IEC 664, VDE 0110, UL 94, IEC 801, IEC 348, IEC 571-1, EN , EN , EN M5-27
28 M.5 CVM Power analyzers Power Net Three-phase power analyzer PowerNet - 0º PowerNet - 90º References PowerNet Units Metering current Quadrants Class Communications Protocol 50 A 2 0,5 RS-485 Net section (mm) Analyzer position with its TC Type 35 mm 0º Power Net M A 2 0,5 RS A 2 0,5 RS A 2 0,5 RS A 2 0,5 RS A 2 0,5 RS A 2 0,5 RS A 2 0,5 RS A 2 0,5 RS A 2 0,5 RS mm 0º Power Net M mm 0º Power Net M mm 0º Power Net M mm 0º Power Net M mm 90º Power Net M mm 90º Power Net M mm 90º Power Net M mm 90º Power Net M mm 90º Power Net M52615 TC-PowerNet Units Metering current Class Net section (mm) Type 50 A 0,5 35 mm TC-PowerNet M A 0,5 35 mm TC-PowerNet M A 0,5 35 mm TC-PowerNet M A 0,5 70 mm TC-PowerNet M A 0,5 70 mm TC-PowerNet M52635 M5-28
29 CVM Power analyzers M.5 TR8 Multi-channel DC voltage and current analyzer Description TR8-RS485 is a measurement unit with up to eight DC channels and a voltage channel, handling up to 1,000 Vdc. Current is measured through eight hall effect transformers (transformers used to measure DC current), with a 25, 100 or 200 A primary. Aplication Photovoltaic applications Power supply Alternating C. Direct C. Nominal voltage 230 Vac 24 Vdc = Power supply tolerance ± 30 % ± 10 % Frequency 50 Hz - Consumption of the equipment without transformers 8 ma / 1.84 V A 70 ma Consumption of the equipment with 8 sensors (no load) 32 ma / 7.36 V A 270 ma Consumption of the equipment with 8 sensors (with current) 32 ma / 7.36 V A 270 ma Operating conditions Operating temperature ºC Relative humidity % RH (non-condensing) Maximum operating altitude 2,000 metres Protection IP 20 TR8-RS485 precision Linearity Error ± 0.1 % Offset Error % I n Total Error ± 0.5 % I n Range 2, % I n Resolution Error ± % I n Error 1 % Transformer precision Linearity Error (not including ± 0.5% Offset Drift / Temp. ±1 mv / ºC offset) Offset Error 25ºC ±10 mv a I n =0 Thermal Gain Drift ±0.05 % / ºC Safety Category III 300 Vac (EN61010) Double-insulated electric shock protection class II M5-29
30 M.5 CVM Power analyzers TR8 Multi-channel DC voltage and current analyzer References x Multi-purpose clips for (pitch of wall mounting holes in din rail clips) /1 y x 6/ y 8 Current Output Communications Description Type Equipment, up to 25 A 25 A 8 RS-485 /RTU 8 25 A dc channels Connection of up to 2 M/TR8-25Ax4 (8 channels) measurement of 1000 V dc 8 voltage-free digital inputs TR8-RS M54600 Measurement module for 4 solar strings. Maximum current: 25 A dc M/TR8-25 x4 M54602 Equipment, up to 100 / 200 A Depends on transformer 8 RS-485 /RTU A dc channels Connection of up to 8 M/TR8-100A or M/TR8-200A One 1000 V dc voltage input 8 voltage-free digital inputs TR8-RS /200 M54601 Measurement module for 1 solar string. Maximum current: 100 A dc M/TR8-100 M54603 Measurement module for 1 solar string. Maximum current: 200 A dc M/TR8-200 M54605 Dimensions TR8-25 TR8-100/ x y φ φ60 φ32 70 Multi-purpose clips for (pitch of wall mounting holes in din rail clips) /1 y x 6/ y V -15V O/P 10.0ø y φ Conections TR8-25 TR8-100/200 M5-30
31 CVM Power analyzers M.5 Accessories CVM-MINI Adaptor Front panel adaptor Description Adaptor for the CVM-MINI for its installation on 72 x 72 mm panels Application For 72 x 72 mm front panel Central fixing Adjustable on the rear with two straps References Type MINI panel adaptor M5ZZF1 Converter TCP2RS Converter of RS-232 / 485 to Ethernet modbus Description Converter of the RS-232 or RS-485 network protocol to Ethernet Power supply V ac / V dc Ethernet speed: 10/100 BaseTX RS Bus transmission speed: 1200 bps to bps Application Converting RS-2323 or RS-485 signals to Ethernet or viceversa References Type TCP2RS-RTU, converter of RS-232/485 to transparent Ethernet (TCP or UDP) TCP2RS, converter of RS-232 / 485 to Ethernet modbus/tcp M54031 M54032 Converter RS-232/485 RS-232/485 Converter Description Converter of the RS-232 network protocol to RS-485 or viceversa The 485 network enables a bus length of 1,200 m Power supply 230 V ac Transmission speed of 4800 bps to bps Control of the RTS signal (in the intelligent mode) Application For any installation with various units connected to an RS-485 network and which must be monitored with an RS-232 connection References Type Intelligent converter RS-232/485 (RTS Control) M54020 Converter RS-232/485 or RS-232/422 M54010 Power supply circuit Consumption Speed Structure R1 and R2 230 V ac (between A1-A2) 3 V A 4800 to bps bits Bridge to connect the final resistor to the line M5-31
32 M.5 CVM Power analyzers Accessories RS-485 / RS-485 Amplifier Description RS-485 Network amplifier The 485 network enables a bus length of 1,200 m Power supply 230 V ac Transmission speed: 1200 bps to bps Application For any installation with various units connected to an RS-485 network and which must be monitored with an RS-232 connection Power supply circuit 12 V dc Consumption 60 ma Operating temperature 0 to 70 ºC References Construction features Type of box Modular. Self-extinguishing plastic Type Protection IP 20 RS-485 Amplifier / Repeater M54080 Dimensions 90 x 18 x 70 mm (1 module) Connection Communications Speed BAUDS ON 11 bits OFF 10 bits ON ON OFF ON OFF ON 9600 ON OFF OFF 4800 OFF ON ON 2400 OFF ON OFF 1200 USB converter USB Converter to RS-232 or RS-485 Description Converter of the USB network protocol to RS-232 or RS-485 Power supply through the PC's USB port Transmission speed: 4800 bps to bps Application To convert the USB signal to RS-232 or RS-485. References Type USB / RS-485 converter USB / RS-232 converter M54040 M54050 M5-32
33 CVM Power analyzers M.5 Relation between products and accessories LM TCP2RS CONVERTER TP POWER STUDIO Adaptor panel Impulse centralizing unit RS-232/485 Converter Ethernet Converter of RS-485 to RS-232 Measuring transformers Management software Adaptor for 72 x 72 panel See M.3 M54032 M54020 depending on the type M90231 M5ZZF1 CVM 96 - CVM CVM BD - CVM BDM - - CVM MINI CVM NRG 96 - CVM k2 - POWER NET M5-33
Measurement and electric control. CVM Power analyzers
Measurement and electric control CVM Power analyzers CVM Power analyzers Nowadays, companies, industries or any consumer of electrical energy are trying to optimise costs to become the most competitive
Contents. Energy saving screen saver. Harmonics measurings up the 15 th or 50 th. Relays with OR option. 0.5% accuracy in voltage and current
CVM system analyzers M5 M.5.01 GB Contents Page Introduction 3 Three-phase system analyzers 4 Applications 5 Three-phase system analyzers CVM-NRG 96 6 CVM-96 7 CVM-144 8-9 CVMk 10-11 Analogue I/O equipment;
Measurement and Control CVM. Power analyzers. Energy efficiency technology
Measurement and Control CVM Power analyzers Energy efficiency technology More than simply measuring... Manage Record the real cost of your manufacturing processes and the kgco 2 emissions of your installation
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Applications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Maximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Distribution of electrical energy
Distribution of electrical energy Technology for energy eficiency Distribution of electrical energy At CIRCUTOR, we have been manufacturing and providing systems and equipment for managing energy efficiency
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series
Communication system for the management of electrical installations INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series MID Approval Technology for energy efficiency PLC Communications (Power Line Communication)
Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144
Automatic Transfer Switch-Controller ATS-C by Eaton Automatic Transfer Switch- Controller ATS-C 96 and C 144 Supply safety for low voltage energy distribution. Automatic Transfer Switch-Controller ATS-C
Electrical Measuring Instruments
Electrical Measuring Instruments Index Contents: Page Measuring Centres MC 320 Energy meter, MC 330 Multimeter 3 MC 760/UMC 760 Network Analyzer, MC 750/UMC 750 - Network Recorder 5 MC 740 Multifunction
M2M The measure of efficiency
M2M The measure of efficiency The importance of control Measurement and advanced analysis of electrical parameters To make equipment as efficient as possible, it is essential to know the details of its
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
PLA 44. Power quality analyzer. User and service manual. BMR trading
PLA 44 Power quality analyzer User and service manual version 1.2 BMR Lipovka 17 516 01 Rychnov n. Kn. 1 Tel: +420 774 415 703 Fax: +420 494 533 602 Content 1. Front panel...3 5.6.1. List of events...8
How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)
100% electricity Digital multimeters and power analyzers series DIGITAL MULTIMETERS AND POWER ANALYZERS with backlit graphic LCD screen For the control of energy distribution systems detecting when problems
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
EARTH LEAKAGE PROTECTION: CONTENTS
EARTH LEAKAGE PROTECTION: CONTENTS Earth Leakage Relays 128-130 Trip Circuit Supervision Relays 128-130 TEMPROTECT Protection and Distribution 1A to 6300A page 127 EARTH LEAKAGE PROTECTION ELR-1E The ELR-1E
Counter for Energy. We make energy measurable and secure your future. www.g-mw.de
Counter for Energy We make energy measurable and secure your future www.g-mw.de 10 reasons for GMW Customer oriented solutions Individual consultancy Satisfied customers in all continents Large range of
Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications
The ZigBee Plug & Play wireless Network for Building and Industrial Applications Energy Management Renewable Monitoring Environment Monitoring Open Modbus Integration Products Range Overview Products Range
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw
Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges
RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System
RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System RTM X42 is an innovative system that utilizes force measuring rollers to capture the tension of individual wires or strands,
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
Electric Measurement and Control. Energy management software
Electric Measurement and Control Energy management software Energy Management software M9 - de gestión energética M9-4 PowerStudio Energy supervision and preventive maintenance of lines and electric installations
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.
56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING
Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter
Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances
TX2123 RS485 TO ETHERNET ADAPTOR
TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485
3-phase, bidirectional energy meter
Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured
Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C
Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Vibration analysis and monitoring Compact. Powerful. Modern technology.
Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
Polyphase kwh Electricity Meter
Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2
Low Voltage Products
Low Voltage Products ABB Power Quality Filters: The most efficient solution for active filtering of harmonics, smooth reactive power compensation and load balancing. Enabling trouble-free and efficient
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet
PowerLogic power-monitoring units PM5350 power meter Technical data sheet Mid-range metering PM5350 Functions and characteristics PE86278 The PowerLogic PM5350 power meter offers all the measurement capailities
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation
DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch
Versions. Q.station Q.station T. Q.station D. Q.station DT x x
Most important features: Very high data rates up to 100 khz each channel 100 khz at 16 channels, 10 khz at 128 channels 64 Q.bloxx modules connectable Ethernet interface for configuration and data output
SCADAPack 530E 535E. remote Programmable Automation Controller
SCADAPack 530E 535E remote Programmable Automation Controller 1 With the SCADAPack 500E range, Schneider Electric introduces the first ever remote Programmable Automation Controller (rpac). This data sheet
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
EM-PQ 1500 Power Quality Monitor. Operating Manual
EM-PQ 1500 Power Quality Monitor Operating Manual 1 User notes: 2 Contents Page Page 1. Quick start... 5 2. Description... 6 2.1 Operating principle... 6 3. Installation... 8 3.1 Mounting... 8 3.2 Electrical
SOLAR300N Rel. 1.03 21/01/10
Photovoltaic installation certifier + professional network analyzer Pag 1 of 5 1. SOLAR300N MAIN FEATURES SOLAR300N performs all tests on PV plants by using of SOLAR-02 remote unit which, after a preliminary
Technical Information POWER PLANT CONTROLLER
Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
Energy Management Power Analyzer Type WM14-96 Basic Version
Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
SYSTEM MONITORING Locally and remotely
StecaGrid 300 StecaGrid 500 StecaGrid 2000+ StecaGrid 2010+ StecaGrid 2020 StecaGrid 3000 StecaGrid StecaGrid 4200 StecaGrid StecaGrid 10000+ 3ph StecaGrid 8000 3ph StecaGrid 10000 3ph monitoring StecaGrid
M1000 Process Alarm Monitor
Data Sheet Process Alarm Monitor Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements
User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)
Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
Modbus Server SAMSUNG Air Conditioners
IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
NX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
SHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
Eaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
SHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Power Meter Series 800
PowerLogic power-monitoring units Power Meter Series 800 Technical data sheet 2007 Functions and characteristics E90463 PB101813-51 PB101823-50 DB111799 Front view of Power Meter Series 800 meter with
Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC
HOJA TÉCNICA 1400H101 Edición 01 (02 de 08) www.ako.es GENERAL TECHNICAL SPECIFICATIONS Temperature range: -50ºC to +99ºC type: NTC Total accuracy ( + controller): ±1ºC lead extension with cable AKO-15586:
Current transformers (CT) & Shunts
Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar
