2 Digital multimeters DMG are capable of viewing the measurements with high accuracy on the wide LCD display, which allow to control energy distribution networks. Easy and intuitive menu navigation LCD display with text in 5 languages Expandability with EXP... modules High measurement accuracy Wide range for power supply, measurements and temperature Suitable for LV, MV and HV electric systems and installations
3 Plug-in modules LCD display with icons and text Optical port Wi-Fi dongle APP The main features include an extended power supply voltage range ( VAC), high measurement accuracy (±0.5% for voltage and current), expandability (using EXP modules) and LCD interactive interface for simple use. Main measurements and functions include: Voltage: phase, line and system values Current: phase values (neutral current calculated) Power: apparent, active and reactive phase and total values Power Factor per phase and total Frequency of measured voltage value HIGH-LOW-AVERAGE value functions for all measurements Maximum demand of power and current values Voltage and current asymmetry Total harmonic distortion (THD): voltage and current Energy meters for active, reactive, apparent partial and total values, per phase and system values Hour counter for programmable total and partial hours Phase active power unbalance.
4 Digital multimeters DMG LCD display New icon type display, with white backlight to ensure good visibility in environments with low light conditions. Scrolling text with 4 characters to show: Alarm messages configured by the user Guide messages for the user Description of the setup menu and parameters. The text is available in 5 languages (English, Italian, French, Spanish and Portuguese). Units of measure Measurement value Optical port DMG 600 and DMG 610 are equipped with a front optical port to support programming through CX 01 and to use the functionality of CX 02 Wi-Fi dongle. Advantages: No need to remove power from the panel to connect to the multimeter Electrical safety (no electrical connection) IP54 guaranteed Convenience of working on the front. USB and Wi-Fi dongle Through the optical port, direct connection to a PC USB port (using CX 01) or via WiFi (using CX 02) is allowed. CX 02 dongle (WiFi) can furthermore make: Copy of the parameters All parameters in the DMG can be saved in the CX 02 memory and in case reloaded on the same device (backup function) or on a different one of the same type (replication of the configuration). Clone of the device settings In addition to the copy of the parameters, the current values of energy meters and hour counters can be saved in memory as well, in order to fully replicate a DMG on another device of the same type or to restore the DMG to a previously saved state. Type of measurement Flashing icon for alarms Bar graph, percentage of a full scale value Subpage indication: Instantaneous measurements, maximum, minimum, average values and maximum demand Active energy meter always available in all pages Limit thresholds On all available measurements, the user can set up to 4 independent thresholds to generate alarms or activate outputs in excess of the set values. The user can decide the activation of the limit threshold on the overcoming of maximum, minimum values or both, with on and off delay to protect the system from unnecessary trippings and hysteresis thresholds to avoid the "bouncing" around the threshold. Voltage Limit thresholds Relay output (using EXP10 03) Relay t t Alarms and notification by flashing display Tied to the limit thresholds or to the activation of a digital input, there are available 4 alarms with user-configurable text description. When an alarm occurs, an icon and a descriptive text appear on any page of the meter. Setting a parameter, the user can activate the flashing of the display backlight in case of alarm. The alarm becomes visible even from a distance, saving a warning light indicating a global alarm. Scrolling text in case of alarms, messages for the user or parameter setup Expandability (1 slot) The configuration of the devices in different installations can have many variants, for example the types of communication (USB, RS485, Ethernet) or the number of inputs and outputs required. DMG 600 and DMG 610 support expandability by EXP... modules. The expansion modules shared with other devices lighten the costs of management and first of all guarantee configuration flexibility at installation time and secondly ease of performance increasing when the system is already in operation. The following EXP modules are available: Digital inputs and outputs (static type to generate energy pulses or relay type to control coils) USB, RS232, RS485 and Ethernet communication. The module is recognized automatically by the base device which set it to be used. The particular shape of the back of the DMG lets the addition of the expansion module without increasing the space required inside the electrical panel, because the size of the EXP module is fully contained in the base module size, limited to 65mm only, including connectors. Management of power "maximum demand" Often in the contracts between user and utility, a limit on the maximum demand of active power, calculated as an average over a time window, exists. In order to help the user, DMG 600 and DMG 610 include features which allow the control of demand limits as follows: 4 methods of integration of active and reactive power: - Fixed window - Moving average - Synchronisation via digital input (typical solution used by utilities) - Synchronisation message via the serial interface (Modbus) Setting a threshold on the average power value, in order to activate outputs which can disconnect non-priority loads to limit the need of power or to notify the user about the need to reduce the loads. kw Peak usage rescheduled to return below lower threshold Peak demand Shaved peak demand t
5 Sam1 APP Furthermore, CX 02 dongle is the access point to the device through the Sam1 APP. Thanks to Sam1, one can: See on smartphones or tablets all the measures of the multimeter Send commands, such as counters reset or enabling and disabling of multimeter outputs Set the parameters, save a copy in a file and retrieve it in case of need (the file can be sent via as well) See active user alarms. Sam1 APP can be downloaded from Google Play Store or Apple itunes. PARAMETER SETTING MEASUREMENT VIEWING SEND COMMANDS ALARM VIEWING Compatibility with Synergy energy management software DMG 600 and DMG 610 are compatible with the current version of Synergy, which can be downloaded from website. Thanks to the built-in RS485 serial port, DMG 610 can be immediately added to an existing network without needing extra external accessories or expansion modules. However, if another type of communication is required, through the modules EXP..., both DMG can be equipped with the EXP10 13, adding an Ethernet port, suitable to work with both static IP and dynamic IP address, making the DMG network configuration similar to which is normally carried out for PCs.
6 HOW TO ORDER LCD multimeters Order code Description DMG 600 Backlight icon LCD, 72x46mmm, auxiliary supply vac / VDC, front optical port DMG 610 Backlight icon LCD, 72x46mmm, auxiliary supply VAC / VDC, front optical port and RS485 port DMG DMG 610 Operational characteristics Auxiliary supply voltage range: VAC / VDC Voltage measurement range: VAC Usage in medium and high-voltage systems with voltage transformers Rated input current: 1A or 5A Frequency measurement range: 45-66Hz True RMS measurements: for voltage and current Measurement accuracy: Voltage: ±0.5% (50-720VAC) Current: ±0.5% ( In) Power: ±1% f.s. Frequency: ±0.05% Active energy: Classe 1 (IEC/EN ) Reactive energy: Class 2 (IEC/EN ) Non-volatile memory for data storage Communication protocol Modbus-RTU, ASCII and TCP Compatible with software and APP Flush-mount housing 96x96mm IEC degree of protection: on front IP54; IP20 at terminals. Certifications and compliance Certifications obtained: EAC, culus. Compliant with standards: IEC/EN , IEC/EN , IEC/EN , UL , CSA C22-2 n Expansion modules EXP10... Order code Description Inputs and outputs EXP opto-isolated digital inputs EXP opto-isolated static outputs EXP digital inputs and 2 static outputs, opto-isolated EXP relay outputs rated 5A 250VAC EXP opto-isolated digital inputs and 2 relay outputs rated 5A 250VAC Communication ports EXP10 10 Opto-isolated USB interface EXP10 11 Opto-isolated RS232 interface EXP10 12 Opto-isolated RS485 interface EXP10 13 Opto-isolated Ethernet interface with web server function Communication ports and accessories CX 01 CX 02 EXP80 00 Order code CX 01 CX 02 EXP80 00 Description USB/optical dongle for PC LOVATO Electric product connection, for programming, data download, diagnostics and firmware upgrade. Complete with cable, 1.8m long Wi-Fi dongle for PC LOVATO Electric product programming, data download, diagnostics and cloning Plastic insert for customising label fixing
7 The products described in this publication are subject to be revised or improved at any moment. Catalogue descriptions and details, such as technical and operational data, drawings, diagrams and instructions, etc., do not have any contractual value. In addition, products should be installed and used by qualified personnel and in compliance with the regulations in force for electrical systems in order to avoid damages and safety hazards. LOVATO ELECTRIC S.P. A. VIA DON E. MAZZA, GORLE (BERGAMO) ITALY Tel Fax Sales Department: Tel Fax Follow us LOVATO Electric offices in the world United Kingdom LOVATO ELECTRIC LTD Tel Czech Republic LOVATO ELECTRIC S.R.O. Tel Germany LOVATO ELECTRIC GmbH Tel USA LOVATO ELECTRIC INC. Tel Spain LOVATO ELECTRIC S.L.U. Tel Canada LOVATO ELECTRIC CORP. Tel Poland LOVATO ELECTRIC SP. Z O.O. Tel United Arab Emirates LOVATO ELECTRIC ME FZE Tel Turkey LOVATO ELEKTR K LTD Tel China LOVATO ELECTRIC (SHANGHAI) CO LTD Tel Romania LOVATO ELECTRIC SRL Tel PD 98 GB LOVATO Electric products are available in over 100 countries through its distributors
How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)
100% electricity Digital multimeters and power analyzers series DIGITAL MULTIMETERS AND POWER ANALYZERS with backlit graphic LCD screen For the control of energy distribution systems detecting when problems
Products and solutions for lifting systems
Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded
Products and solutions for pumping, irrigation and piping
Products and solutions for pumping, irrigation and piping 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric
Energy meters For an efficient control of energy consumption
Energy meters Energy meters For an efficient control of energy consumption In a modern world in which energy must be monitored and controlled in the most efficient way possible, LOVATO Electric presents
Supervision and energy management software
Supervision and energy management software Supervision and energy management software software Applications Supervision for industry, shopping malls Quality control of power grid supply Consumption accounting
Products and solutions for machine builders (OEM) 100% electricity
Products and solutions for machine builders (OEM) 100% electricity www.lovatoelectric.com Tra dition and innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters
Energy quality analysis. Load protection. Renewable energy. On request or periodic load. management
Energy management Energy management Energy quality analysis Load protection Energy quality control v t Non-priority load management On request or periodic load management Renewable energy Power factor
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
M2M The measure of efficiency
M2M The measure of efficiency The importance of control Measurement and advanced analysis of electrical parameters To make equipment as efficient as possible, it is essential to know the details of its
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
Applications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series
Communication system for the management of electrical installations INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series MID Approval Technology for energy efficiency PLC Communications (Power Line Communication)
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
F453. TiF453. User guide 10/11-01 PC
F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental
Metering devices. Features The high-quality measuring technology of the device facilitates 4-quadrant power metering. In this way, metering
Metering devices Current grid values of your power distribution system at a glance at all times. Multifunctional metering devices by EFEN have an important share in improving energy efficiency and system
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
Energy Management Power Analyzer Type WM14-96 Basic Version
Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description
INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS stam-irs_en 01/11 STAM-IRS is a dedicated server to be used with the STAM-2 monitoring station which enables receiving transmissions sent via telephone
Remote Monitoring Unit SC8100. Monitoring Unit SC8100
Monitoring Unit SC8100 Remote Monitoring Unit SC8100 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with all
VERTELIS SUITE A software suite to manage your energy performance
VERTELIS SUITE A software suite to manage your energy performance Drive reductions in your energy consumption Energy and facility managers of commercial and industrial sites, your challenge is to improve
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
EARTH LEAKAGE PROTECTION: CONTENTS
EARTH LEAKAGE PROTECTION: CONTENTS Earth Leakage Relays 128-130 Trip Circuit Supervision Relays 128-130 TEMPROTECT Protection and Distribution 1A to 6300A page 127 EARTH LEAKAGE PROTECTION ELR-1E The ELR-1E
Remote Sources. Facility. Router
A tally display system is an essential part of any broadcast or production environment. It must tell you where signals come from, where they go, and how they are being used. In a typical multi-production
SHEET. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series
EIPR Series d a t a SHEET EIPR Skorpion Wired and Wireless IP Routers The EIPR links two Internet Protocol (IPv4) networks together passing appropriate traffic while blocking all other traffic. One of
Back-UPS Pro 1300/1500 Installation and Operation
Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
EnerVista TM Viewpoint Monitoring v7.10
EnerVista TM Viewpoint Monitoring v7.10 Guideform Specifications July 7, 2014 Page 1 of 14 1 - Product Overview 1.1 Viewpoint Monitoring Scope EnerVista Viewpoint Monitoring is an easy to setup, powerful
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
PLA 44. Power quality analyzer. User and service manual. BMR trading
PLA 44 Power quality analyzer User and service manual version 1.2 BMR Lipovka 17 516 01 Rychnov n. Kn. 1 Tel: +420 774 415 703 Fax: +420 494 533 602 Content 1. Front panel...3 5.6.1. List of events...8
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
GUIDE. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series
a p p l i c a t i o n GUIDE EIPR Series EIPR Skorpion Wired and Wireless IP Routers The EIPR links two Internet Protocol (IPv4) networks together passing appropriate traffic while blocking all other traffic.
Installation and Operation Back-UPS 1250, 1300, 1500
Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS
AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS AGRI-ALERT ALARM SYSTEMS Peace of Mind Agri-Alert is a complete alarm system for monitoring temperature, power, feed and watering systems, burglary,
Electrical Network Management System
Electrical Network Management System Optimisation of the electrical network Measure to understand Understand to control Control to optimise Cost of power and fluids Power quality Power availability 2 Improvement
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
Simple Electrical Utility Cost Allocation Solutions
Simple Electrical Utility Cost Allocation Solutions PowerLogic High Density Metering Advanced Submetering and Multi-Tenant Metering Buildings Retail Multi Residential DATA CENTER SOLUTIONS For More Information:
Indoor / Outdoor Antenna
z300 High Precision NTP Time Server Indoor / Outdoor Antenna High Precision NTP Time Server with PoE (Indoor or Outdoor use) synchronized by GPS Revision 4 ZTI / 1 boulevard d'armor / BP 20254 / 22302
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
SOFTWARE EasyComm (Code 775 044) USER S MANUAL (Code M 981 357/00 - A) 1997-2000 CIRCUTOR, S.A. All rights reserved
SOFTWARE EasyComm (Code 775 044) USER S MANUAL (Code M 981 357/00 - A) 1997-2000 CIRCUTOR, S.A. All rights reserved EasyComm INDEX 1. Introduction... Page 2 2. EasyComm contents... Page 2 3. Main features...
Technical note NT588 NT604 NT695 NT782
Multifunction 1.01 Model Nemo D4-b Nemo D4-L Nemo D4-L+ Codes MF6GT MF6FT0 MF6FTU MF6FT4 MF6HTU... MF6HT4... MF6HB... Ordering codes see page: 08 08 08 08 08 08 08 Connection on line single phase, 3-phase
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
MXL2 Dash Logger USER GUIDE
Dash Logger USER GUIDE AiM Srl. Via Cavalcanti, 8 20063 Cernusco S/N (MI) Italia Tel. (+39) 02.9290571 Made in Italy www.aim-sportline.com Dash Logger 04 06 08 10 11 12 12 12 14 14 14 14 16 17 18 19 21
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
Generator Differential Relay Electrical Apparatus
Generator Differential Relay Electrical Apparatus MD3G Rotating Machine Differential Relay 150-3 The MD3G Rotating Machine Differential Relay is a member of Cooper Power Systems Edison line of microprocessor
Passion for Innovation
Passion for Innovation A Complete Solution Hardware All the Alveo servers are designed and optimized to manage the home automation system. They arebuilt for continuous operation with fanless processing
POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH
ENGLISH POS UNITS Installation and user guide Count, video recording and POS control unit INDEX 1 FUNCTIONALITY... 2 2 GENERAL CONSIDERATIONS... 4 3 CAMERAS INSTALLATION... 5 3.1 CAMERA TYPES... 5 3.2
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage
Data Loggers for Real Time Temperature Monitoring - WiFi
Data Loggers for Real Time Temperature Monitoring - WiFi Main Features Complete standalone system. Even if computer/network does not operate the recording system will continue to record without any interruption.
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter
Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances
Modbus and ION Technology
70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible
Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications
The ZigBee Plug & Play wireless Network for Building and Industrial Applications Energy Management Renewable Monitoring Environment Monitoring Open Modbus Integration Products Range Overview Products Range
PMS. Energy management and monitoring software. Installation and operation instructions
PMS Energy management and monitoring software Installation and operation instructions version 1.0 Czech Republic Czech Republic 1 Content 1. PMS introduction... 3 1.1. PMS structure... 3 1.2. System requirements...
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
rigel 288 Electrical Medical Safety Analyser Key Features Applications
rigel 288 Electrical Medical Safety Analyser Key Features Versatile Test in Accordance with the leakage requirements of IEC/EN 60601-1, AAMI and NFPA, IEC 62353 (VDE 0751-1) using separate IEC 60601 and
Olson Electronics Remote Power Monitoring Meter
Olson Electronics Remote Power Monitoring Meter Operation Guide Key Features Amps: 00.00 to 32.00A True RMS (rated short period to 40A) Volts: 200.0 to 250.0V True RMS Watts: 0000 to 9999W KWh: 000000.0
Eaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
PowerCommand 500/550 Remote Monitoring System
PowerCommand 500/550 Remote Monitoring System Complete remote monitoring of your power system The PowerCommand 500 series provides a convenient means of remotely monitoring generator sets, transfer switches,
Technical Overview CM-2 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk
Technical Overview CM-2 Climate Monitor Get yours direct at: 01491 410913 www.theclimate.co.uk The importance of effectively monitoring IT environments has never been greater. There are a multitude of
Static energy meters
Static energy meters 2.01 Model Conto D1 Conto D2-b Codes CE11165A0 CE11165A2 CE21175A0 Ordering codes see page: 09 09 09 Connection on line single-phase single-phase Active energy class 1 EN62053-21 class
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
PowerLogic Sub Meter Display (SMD and SMDOPN)
Instruction Bulletin Z203742-0B PowerLogic Sub Display (SMD and SMDOPN) CONTENTS Introduction... 2 Parts of the Sub Display... 3 Dimensional Drawing... 4 Installation... 5 Mounting the SMD... 5 Mounting
DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.
Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
Section 16935 TELEPHONE AUTOMATIC DIALER SYSTEM
Section TELEPHONE AUTOMATIC DIALER SYSTEM PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Design Requirements: 1. Electronic monitoring system shall interface plant alarms to public telephone system or cellular
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
SHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
Gauge Drawing Tool... 8. Slider Drawing Tool... 8. Toggle Button Drawing Tool... 8. One-Way List Drawing Tool... 8
v. 20120510 Table of Contents RTiPanel Overview and Requirements... 3 Software Requirements:... 3 Hardware Requirements:... 3 Network Requirements:... 3 Licensing Requirements:... 4 Basic Integration Designer
APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700
Tel: +90-216 466 84 60 Fax: +90-216 364 65 65 [email protected] http://www.datakom.com.tr APPLICATION NOTE Ethernet Configuration Guide for D-500 D-700 PRODUCTS AFFECTED: D-500 / D-700 WRITTEN BY:
Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation
DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
ENTBUS PLUS SOFTWARE FOR ENERGY MONITORING AND RECORDING INSTALLATION AND OPERATING MANUAL
ENTBUS PLUS SOFTWARE FOR ENERGY MONITORING AND RECORDING INSTALLATION AND OPERATING MANUAL Foreword Entbus services manage the collection of information and storing this information in the database. Services
Nemo 96HD/HD+ MODBUS
18/12/12 Pagina 1 di 28 MULTIFUNCTION FIRMWARE 2.30 Nemo 96HD/HD+ MODBUS COMMUNICATION PROTOCOL CONTENTS 1.0 ABSTRACT 2.0 DATA MESSAGE DESCRIPTION 2.1 Parameters description 2.2 Data format 2.3 Description
User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720
User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller Manual version : v1.00 Networking and MIS Manual Dryer controller Page 1 of 16 Document history Preliminary version
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
F454. Web Server. User Manual 05/12-01 PC
F454 Web Server User Manual 05/2-0 PC 2 Web Server Contents Introduction and basic functions 5. Connection modes 6.. Connection to the data network 6..2 Remote connection 6.2 Using the Web Server with
Ethernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Using the JNIOR with the GDC Digital Cinema Server. Last Updated November 30, 2012
Using the JNIOR with the GDC Digital Cinema Server Last Updated November 30, 2012 The following is an explanation of how to utilize the JNIOR with the GDC Digital Cinema Server. Please contact INTEG via
Electrical Measuring Instruments
Electrical Measuring Instruments Index Contents: Page Measuring Centres MC 320 Energy meter, MC 330 Multimeter 3 MC 760/UMC 760 Network Analyzer, MC 750/UMC 750 - Network Recorder 5 MC 740 Multifunction
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
Home Station ADSL. You may also use the following address (regardless of whether you have changed the primary address or not):
TABLE OF CONTENTS 1 Introduction 1 2 User interface overview 2 3 LAN and WLAN settings 8 4 Setting the Internet connection 11 5 Settings and status of devices connected to your router 13 6 Configure applications
smart-house Controller Central Unit Module Type SH2WEB24
smart-house Controller Central Unit Module Type SH2WEB24 Home automation functions and energy data logging configurable by software Micro PC with Web-server Linux embedded operating system Two RS485 communication
In-Sight Hardware specifications
specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 4020 Linz/Austria Pummererstr. 36 Tel.: +43-(0)70-7646-0* www.schmachtl.at Memory Job/Program 16MB non-volatile flash memory; Unlimited
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC