FSLIMRF05-10 - 15-20 - 25



Similar documents
WIRELESS MAGNETIC CONTACT

PROXIMITY CARD READERS C-10, C-20, C60, C70

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION

Adaptability to Enhanced Security

Adaptability to Enhanced Security

Wireless Home Security Alarm System AM 500

GE Wireless Devices Battery Replacement

Automatic Telephone Dialer TD-101(W)

IN-OUT Thermometer with Cable Free Sensor and Clock

Wireless Alarm system s manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Shadow TX(A) Shadow RX

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

GSM HOME SECURITY SYSTEM

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

NAS-1000 AIS-SART USER S MANUAL NEW SUNRISE

Digital Keypad Use s Manual

HM-W536 Install Guide

Shunt lock function 3066

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

User Guide. Model: MAS-WA-SYS

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Water Tank Level Monitor

PCS300 Universal IP Reporting Module V1.0

CAD-05 Kit GSM Auto Dialer. Owner s Manual

Business/Home GSM Alarm System. Installation and User Manual

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

How To Use A Power Supply On A Powerline 2.2 (Ai)

Stove Guard Kit User Manual

1pcs. 1pcs. 2pcs 1pcs 1pcs 2pcs

NOQ_NQ-9121 Z-Wave Data Logger for Gas Meters Firmware Version : 2.55

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

WIRELESS HOME ALARM SYSTEM (WHA1)

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

GSM Autodialer Professional GJD700 Speech & Text Autodialer

site monitoring Kit Site Monitoring Kit User Manual we prove it.

AD-01 Slave Auto Dialer. Owner s Manual

ST815 Illumination Sensor with LCD

How To Program An Autodialer

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

User Manual. Before installation and use, please read the user manual carefully.

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

2-Way Wireless Indoor Siren Installation Guide

MOBILE CALL GSM Alarm System User s Manual

OPL BASIC. Dosing System for Professional Laundry machines. Contents

MotorCycle Alarm by DEF COM 3 INSTALLATION MANUAL 80 C

Intelligent GSM Auto-Dial Alarm System

Contents. Document information

WIRELESS STATUS MONITOR

Operating Instructions. UL325 Compliant Non-monitored

Transmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

Inwall 4 Input / 4 Output Module

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

GSM ALARM SYSTEM USER MANUAL

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Intelligent GSM Auto-dial Alarm System User s Manual

Advantium 2 Plus Alarm

WIRELESS WATER LEAK DETECTOR

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

FIREDEX Conventional Fire Panels

RC2200DK Demonstration Kit User Manual

Business/Home. GSM Alarm system

Wireless Alarm System

SECTION DETECTION AND ALARM

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

500r+ Installation and User Guide

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Combi B Alarm box. Mounting instructions

AIS750 Series Alarm Annunciator

TABLE OF CONTENTS. TABLE OF CONTENTS... 1 Package content INTRODUCTION Dear customer... 2 Features... 2 Caution... 2

MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system way pager system

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

HWS100 Wireless Home Security System

TS510 & TS500. Installation & User Guide. Compatible Equipment

Emergency Dialer DIAL-ALERT MODEL: AD

Autodialler. Installation & Programming Guide HYL004. Please read these instructions before you start the installation. Installation.

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

Business/Home GSM. Alarm System(III) Installation and Users guide

Model 201 Wiegand Touchpad Reader Installation Guide

Users Manual of GSM Home Alarm System with Photo-taken

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

DC-8706K Auto Dial Alarm System

TITAN 12 Dual SIM Security & Management System

GSM Alarm System User Manual

TruPower-Portable-500W. Solar Starter kit

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

Transcription:

1. INTRODUCTION FSLIMRF is a fully wireless, battery-powered infrared beam barrier for the protection of doors and windows with alarm radio transmission. The barrier is made up of two aluminium sections housing the infrared beam transmitters and receivers, closed by two black polycarbonate covers. The assembled sections may be cut to size and hence perfectly adapted to the height of the passageway to be protected. The base unit comprises a master and a slave card that generate a two beam barrier which may be expanded to generate additional beams (FSLIMPLUS) up to a maximum of 8. The additional beams may be freely positioned inside the sections so as to fully adapt the protection to all installation requirements. For yet even greater installation flexibility, sections are available in various sizes (from 0.5m to 3m). Profiles are firmly secured by means of screws and O rings and plugs are especially shaped to always ensure against any screw or O ring loosening, thus also making for perfectly safe outdoor installation. 2. TECHNICAL SPECIFICATIONS Power Consumption Battery life Tripping time Alarm frequency - 3.6V with 2 AA format, 2.7Ah Lithium-Thionyl Chloride batteries - alternatively, connection to a terminal strip for 12VDC powering or to a connector for 3.6V off-board battery pack powering. - 280µA with 4 beams in standby - 550µA with 8 beams in standby - 10mA during radio transmission of the FSLIMTX module - 20mA during buzzer sounding with FSLIMOUT filar module Max 2 years with 4 beams and battery provided Max 1 year with 8 beams and battery provided 300ms or 900ms, selectable via FUNCTION dip-switch an at least 10-second interval between one alarm and the other. Infrared beam range Beam wave length 6 meters indoor, 3 meters outdoors 950 nm Tripping logic Outputs Alarm type Supervision interval 1 or 2 beam break-off, selectable via FUNCTION dip-switch - via radio with 5-channel, 433MHz FSLIMTX transmitter - by relay (2 clean N.A./N.C. exchange contacts) via FSLIMOUT filar interface Beam break-off, beam resetting, flat battery, supervision (disabled via the jumper), tamper 60 minutes Operative temperature -20 C +55 C Radio transmission frequency Radio transmission range Code type Settings Signals Controls 433.92MHz 150m outdoors, 50m indoor Unique for each barrier, with proprietary rolling algorithm Triggering-time selection Triggering-logic selection (1 or 2 beam cut-off) Enabled beam selection BUZZER indicating beam alignment (enabled only during alignment procedure) LED indicating radio transmission (diseblable by appropriately acting on the jumper) RESET button to get barrier running. ALIGN/RADIO button to perform alignment and barrier test. 1

3. MAIN FEATURES Aluminium section. Top rubber and bottom ABS plugs with sponge-protected bottom aperture for proper aeration and hence condensate and insect penetration prevention inside the column to avoid the risk of damaging the photocells. Polycarbonate cover. Wall mounting by screws and O rings provided. Four pairs of transmitter + receiver sensors provided as standard. Possibility of expanding to up to 8 pairs of sensors (additional beam code FSLIMPLUS). Transmitter and Receiver sensors sliding on appropriate inner guide and securing by means of screws. Break-in and tear-off prevention tamper (may be cut out by acting on the NO TMP1 and NO TMP2 jumpers accordingly) for each column. Incorporated photocell amplifier with the following technical characteristics: multiplexed and synchronised system; up to 8 beam management with 2 by 2 selection. Output: 5 channel radio transmitter (alarm, end alarm, supervision, flat battery, tamper). Alternatively, filar interface card for off-board radio transmitter fitted with two N.O./N.C. exchange relays for alarm and flat battery signal transmission. Simple alignment procedure for easy sensors installation and alignment. Enabling of beam employed by means of the four-contact BEAM dip-switch. Buzzer for alignment signalling during installation. Operating mode selection by means of the FUNCTION dip-switch as specified in the table herewith: 4. OPERATING PRINCIPLE Dip 1 Dip 2 Alarm enabling ON ON One beam cut-off for at least 0.3 seconds ON OFF One beam cut-off for at least 0.9 seconds OFF ON Two beams cut-off for 0.3 seconds OFF OFF Two beams cut-off for 0.9 seconds The FSLIMRF05 infrared beam barrier features a MASTER and a SLAVE card with beam 1 on board. All other FSLIMRF10-15-20-25 barriers equally feature a MASTER and a SLAVE card with beam 1 on board and an additional beam made up of a pair of TX transmitter and RX receiver sensors. Each beam is made up of a 2-way (outgoing and incoming) infrared beam cluster; the MASTER transmits the signal to the SLAVE, which correctly receives it and returns the transmission to the MASTER, essentially behaving as an electronic mirror. The barrier has a four-beam management capacity (8 clusters in all), which may be expanded, even by one beam at a time (code FSLIMPLUS when ordering). RX TX BEAM 2 TX RX RX TX BEAM 1 TX RX MASTER SLAVE 2

The barrier transmits an INTRUSION alarm upon 1 or 2 beam break-off, depending on setting. Upon all enabled beams being reset, the barrier transmits the END ALARM signal, following which any further beam break-off within the next 10 seconds will be ignored. Upon power of any of the 3V batteries becoming feeble, the barrier transmits a BATTERY FLAT signal. The signal is repeated every 24 hours, until battery has goes fully flat. The barrier transmits a supervision signal every 60 minutes. The signal may be disabled as a power-saving measure by acting on the SUPERVISION jumper accordingly. 5. FSLIMRF MOUNTING 5.1 Setting up and securing 1. Cut the black anodized aluminium sections and polycarbonate cover to size, as required. 2. Locate where to drill the hole for securing the sections to the wall and fitting the rip-off prevention tamper if required. 3. Drill a hole with a Ø 4 bit for the securing and a Ø 10.5 bit for the rip-off prevention tamper. 4. Fit the TX Transmitter and RX Receiver sensors inside the sections, positioning them as desired and securing by means of the self-tapping screw provided (Figure 1). 5. Fit the rubber plug onto the top end of the section (Figure 3). 6. Insert the sponge wad inside the plastic plug so as to cover the condensate drain hole. Fit the plastic plug onto the section (Figure 5). 7. Insert the rip-off prevention rubber tamper triggers into the appropriate holes and fit the springs on the opening prevention tamper (Figure 2). If the rip-off and/or opening prevention tamper/s is/are not to be used, check that the NO TMP2 and/or NO TMP1 jumper/s is/are inserted. 8. Secure the sections to the wall by means of the securing screws and O rings. 9. Fit the sensor ribbon-wire inside the section and secure in place by means of the spring provided (Figure 1). 10. Fit the lithium batteries inside the appropriate compartment according to correct polarity or, alternatively, connect a 12VDC power line to the terminal on the card. The barrier is now fully operative according to default settings. Master/Slave Terminal-strip +12V GND 11. Plug the FSLIMTX radio transmitter or the FSLIMOUT filar interface into the red micro-match connector. FSLIMTX FSLIMOUT 3

12. Beam alignment procedure a) After having fitted the batteries in the Master and Slave card, make sure that the tampers that have not been purposefully cut out by means of the jumper are enabled. To check sensor alignment at this stage, cutting out of all tampers by means of the corresponding NO TMP jumpers is advisable. b) Press the RESET button on the Slave card. c) Press the RESET button on the Master card; the buzzer will give out 4 beeps. d) Press the ALIGN/RADIO button before the fourth beep sounds. e) If the beams are aligned the buzzer will give out a continuous trilling sound and no sound if not. In case of non-alignment, align each beam separately, enabling one beam at a time on the Master and Slave circuit by means of the DIP BEAM dip-switch. Once beams are aligned, check that buzzer stops trilling upon one of the beams being broken off. Lift one of the NO TMP jumpers on the SLAVE card and check that the buzzer stops trilling. f) Once proper beam operation has been checked, exit alignment mode by pressing the RESET button on the MASTER card. g) Press the ALIGN/RADIO button to radio transmit an alarm as an example for receiver to learn the barrier code. 13. Fit on the polycarbonate cover as shown in Figure 3. 14. Fit the plastic spring onto the plastic plug as shown in Figure 4 to cover any rough cutting edge on the section. 15. Run a final beam alignment check after completing the installation. 5.2 Settings and adjustments 1. Only enable connected beams, proceeding as follows: a) identify beam to be employed (2,3,4) by means of the jumper provided in the TX and RX sensors, bearing in mind that each beam is actually made up of a two-way (out-going and in-coming) beam cluster (see section 4 for further details); Beam 2, 3, or 4 selection b) set to OFF the DIP BEAM dip switches of the beams employed located in the MASTER card, which is identified by the presence of the buzzer and the red 8-pole micro-match connector; Off-board 3.6V power pack connector 12VDC-powering terminal strip AA 3.6V 2.7Ah battery Supervision signal enabling jumper NO TMP1 opening protection jumper Reset button Radio Alignment Button Beam enabling DIP BEAM dip switch NO TMP2 tear-off protection jumper Buzzer Alarm mode selection DIP FUNCTION dip switch 4

c) set to OFF employed beam DIP BEAM dip switches in the SLAVE card. Off-board 3.6V power pack connector AA 3.6V 2.7Ah battery lodgement 12VDC-powering terminal strip NO TMP1 opening protection jumper NO TMP2 tear-off protection jumper Reset button Beam enabling DIP switch Tear-off protection Tamper Alarm mode selection DIP Switch DIP BEAM (beam) ON 1 2 3 4 Beam enabled OFF Beam disenabled 2. Select desired alarm mode with Master and Slave DIP FUNCTION 1 and 2 FUNCTION ON 1 2 3 4 Alarm Triggering Mode OFF Dip 1 Dip 2 Alarm triggering upon ON ON one beam break-off for at least 0.3 seconds ON OFF one beam break-off for at least 0.9 seconds OFF ON two beams break-off for at least 0.3 seconds OFF OFF two beams break-off for at least 0.9 seconds N.B.: DIPs 3 and 4 are not currently operative and are available for future applications. 5

5.3 FSLIMOUT Filar plug-in Interface Card Off-board radio transmitter interfacing for alarm and flat battery signal transmission may be made thanks to two clean NO or NC (selectable by means of the ALARM and BAT jumpers) contacts in the filar interface card. NC1 - C : alarm contact NC with ALARM jumper set to NC, NO with ALARM jumper set to NO. NC2 - C : flat battery contact NC with BAT jumper set to NC, NO with BAT jumper set to NO. 5.4 FSLIMTX 433 Mhz Plug-in Radio Transmitter Card The 433MHz radio transmitter card has a 5-different-signal transmission capacity, and namely: - alarm; - end alarm; - supervision; - flat battery; - tamper. Disconnect jumper for energy-saving LED cut-out, if desired. 6

. Beam expansion connector Flat cable securing spring RX card securing screw Beam selection jumper 12VDC powering terminal Sensor connecting flat cable 3.6V off-board battery connector Transmitter LED cut- out jumper Supervision cut-out jumpe Plug-in radio transmitter module AA 3.6V 2.7Ah lithium batteries Align/Radio pushbutton Buzzer DIP BEAM beam selection dip switch DIP FUNCTION alarm mode selection dip Opening protection cutout jumper Opening protection tamper Tear-off protection tamper Tear-off protection jumper cut-out Reset push button 7

Fig. 2 Fig. 3 RUBBER PLUG TAMPER SPRING TEAR-OFF PROTECTION TAMPER FAIRLEAD Fig. 4 Fig. 5 PLASTIC PLUG COVER PLASTIC PLUG SPONGE 8