Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP

Similar documents
Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S

Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System

Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, and AXXRPFKSNSH Installation Guide

Intel RAID Maintenance Free Backup Unit AXXRMFBU2 User s Guide

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Intel Server System P4000RP Family Service Guide A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products

Intel Remote Management Module User s Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

Replacing the Gateway M675 Keyboard

Small form factor bay converter and hard drive installation

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Replacing the Gateway M320 Keyboard

Intel RAID Maintenance Free Backup Unit AXXRMFBU2 User s Guide

Intel SC5100 Pedestal and Rack Server Chassis Subassembly Product Guide

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

Wall-Mounting your HP computer. User Guide

StorTrends 3400 Hardware Guide for Onsite Support

HP SATA/SAS hard drive and Solid State Drive installation

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Intel Storage Server SSR212MC2/ SSR212MC2R User Guide

Intel NUC Kit DC3217IYE User Guide. Intel NUC Kit DC3217IYE

Upgrading and Servicing Guide

Hard Disk Drive (HDD)

Service Guide. Gateway M275

Rack Installation Instructions

HP ProLiant DL165 G7 Server. Installation Instructions

HP Optical Bay Hard Drive Bracket

Quick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3

HP 22-in-1 Media Card Reader

NovaScale Blade 2GB Brocade SAN Switch Module (BBRM)

ProLiant DL380 Generation 2 Server Maintenance and Service Guide

Installing Your 960 or 980 Server into a Rackmount Cabinet

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Inspiron 15. Service Manual Series

EasyNote TJ Series. Disassembly Manual

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.

HP UPS R1500 Generation 3

Dell Inspiron 660s Owner s Manual

UPGRADING AND SERVICING GUIDE

Inspiron 13. Service Manual Series. Computer Model: Inspiron Regulatory Model: P57G Regulatory Type: P57G001

Intel Gigabit Ethernet Switch AXXSW1GB User Guide A Guide for System Administrators of Intel Server Products

SERVICE GUIDE. Gateway Notebook

Intel Server Board S5520HC, S5520HCT and S5500HCV Service Guide

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

PS6500 Storage Arrays Rack Mount Instructions

Packard Bell Easy Repair 1. Packard Bell Easy Repair

Installation Instructions

How To Install A Power Supply (Uplast) With A Battery Pack

Memory Modules User Guide

Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide

Dell E Series Monitor VESA Mounting Bracket Installation Instructions

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

Installation Guide. Wyse C Class 2-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

Access Server Rack Cabinet Compatibility Guide

Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

HP LaserJet MFP Analog Fax Accessory 300 Fax Guide

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Internal USB port kit installation

Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: PN: L Rev.

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

REMOVE AND REPLACE AIR CONDITIONER. 170 Popular Dodge REMOVAL: AIR CONDITIONING Section 4 Page 1

Intel Server System S7000FC4UR

MAXDATA PLATINUM Blade Server. User s Manual

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Rack installation instructions

Intel Remote Management Module 2 User Guide

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

Intel Server System SC5650HCBRP Service Guide

Removable 2.5 SATA HDD Backup System

Tyan Computer. Transport PX22. Service Engineer s Manual

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Changing the SIM in a BANDIT Product s GSM Card

Power Supply Guide Version 1.0 for D-Show

HP Integrity rx2660 Server Installation Guide

Installation Guide. Wyse C Class Conversion to WES7. Wyse USB Firmware Tool TM Release Issue: PN: L Rev. B

Intel Entry Server Chassis SC5275-E

Acer Aspire One AOA Disassembly

Internal Modem Installation with Windows 95

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

TeamPoS 2000 Installation Instructions Upgrade to M Motherboard

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

To view this information... Installing additional tape drives page 5 Replacing a tape drive with the same configuration

FUSION R400 RAID USB 3.0

User Manual. One / One S / One S3

Intel Desktop Board DG43NB

Refer installation of power supplies to qualified service personnel.

Front Panel Board Cable Replacement Instructions

Intel Technical Advisory

42U/45U 28" Wide Rack Installation & Service Guide

Processor Cage Fans, Front and Rear Replacement Instructions

Intel RAID Controller Troubleshooting Guide

HP Laser Jet 2400 Series Fixing Drive Side Plate Assembly Fixing Drive Side Plate Assembly- RM page 1

Recovery BIOS Update Instructions for Intel Desktop Boards

Transcription:

Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Intel Order Number: D13321-002

Disclaimer Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice. Intel server boards contain a number of high-density VLSI and power delivery components that need adequate airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits. Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright 2005-2006, Intel Corporation. All Rights Reserved ii Rack Mount Kit Install Guide

Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel Server Deployment Toolkit CD and/or at http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und Servergehäusen auf der Intel Server Deployment Toolkit CD oder unter http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Consignes de sécurité Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel Server Deployment Toolkit CD ou bien rendezvous sur le site http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Instrucciones de seguridad importantes 重 要 安 全 指 导 Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel Server Deployment Toolkit CD y/o en http://support.intel.com/ support/motherboards/server/sb/cs-010770.htm. 在 执 行 任 何 指 令 之 前, 请 阅 读 本 文 档 中 的 所 有 注 意 事 项 及 安 全 声 明 和 / 或 http://support.intel.com/support/motherboards/server/safecert.htm 上 的 Intel Server Boards and Server Chassis Safety Information( Intel 服 务 器 主 板 与 服 务 器 机 箱 安 全 信 息 ) Rack Mount Kit Install Guide iii

Safety Information Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold. System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components. Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result. Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts. ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. iv Rack Mount Kit Install Guide

Contents Contents Safety Information... iii Important Safety Instructions... iii Wichtige Sicherheitshinweise... iii Consignes de sécurité... iii Instrucciones de seguridad importantes... iii Rack Mount Kit Installation Instructions... 1 Before You Begin...1 Kit Content List... 1 Tools and Supplies Needed... 1 System References... 2 Installation Instructions...2 Prepare Chassis... 2 Install Rack Handle... 5 Prepare Rack Rail Assembly... 8 Complete Setup... 11 Rack Mount Kit Install Guide v

Contents vi Rack Mount Kit Install Guide

List of Figures List of Figures Figure 1. Removing Chassis Feet... 2 Figure 2. Removing Top Side Cover from Chassis... 3 Figure 3. Removing PCI Card Guide... 3 Figure 4. Removing Plastic Filler Panel from Chassis... 4 Figure 5. Removing Plastic Plugs... 4 Figure 6. Removing Rear Screws... 5 Figure 7. Removing Plastic Plugs from Top Side Cover... 5 Figure 8. Installing Rack Handle on Left Side Cover... 6 Figure 9. Affixing Label to Front Panel... 6 Figure 10. Installing Top Side Cover on Chassis... 7 Figure 11. Detaching Inner Rack Rail from Rack Rail Assembly... 8 Figure 12. Attaching Inner Rack Rails to Chassis... 9 Figure 13. Attaching Outer Rack Rails to Rack Uprights... 10 Figure 14. Installing Chassis into Rack... 11 Rack Mount Kit Install Guide vii

List of Figures viii Rack Mount Kit Install Guide

1 Rack Mount Kit Installation Instructions Use the instructions in this installation guide to convert the Intel Entry Server Chassis SC5295-E or Intel Entry Server Chassis SC5299-E from a pedestal/tower configuration to a rack mount configuration. Before You Begin Kit Content List Before converting your system to a rack mount configuration, observe these safety guidelines: 1. Turn off all peripheral devices connected to the server. 2. Turn off the server by pressing the power button on the front of the chassis. Then unplug the AC power cord from the chassis or wall outlet. 3. Label and disconnect all peripheral cables and all telecommunications lines connected to I/O connectors or ports on the back of the chassis. 4. Provide electrostatic discharge (ESD) protection by wearing an anti-static wrist strap attached to a chassis ground - any unpainted metal surface - when handling components. Each Rack Mount Kit contains the following: Rails (2) Rack Handle Front Panel Label Screws for Rack Handle (4) Screws for Rack (8) Screws for Guides (6) Screws for Rack security (2) Tools and Supplies Needed Phillips* (cross head) screwdriver (#1 bit and #2 bit) Anti-static wrist strap and conductive foam pad (recommended) Rack Mount Kit Install Guide 1

System References All references to left, right, front, top, and bottom assume the reader is facing the front of the chassis as it would be positioned for rack-mount operation. Installation Instructions Prepare Chassis 1. Read all caution and safety statements listed in this document before performing any of the steps. See the Intel Server Boards and Server Chassis Safety Information document at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm for a complete listing of all caution and safety statements. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Lay the chassis down on its right sid, as shown in Figure 1. 4. If installed, remove the chassis feet. Remove pin from rubber foot (see letter A in the following figure). Remove rubber foot from chassis hole (see letter B ). Repeat process for remaining feet. A B TP01710 Figure 1. Removing Chassis Feet 2 Rack Mount Kit Install Guide

5. If present, remove the two screws securing the top side cover to the rear of the chassis. Remove top side cover by pressing the latch and pushing back on the cover. TP00958 Figure 2. Removing Top Side Cover from Chassis 6. Remove any installed PCI Add-in Boards. Remove the PCI card guide by pressing in on the blue tabs (see letter A in the following figure) and pulling the PCI card guide outward (see letter B ). A B Figure 3. Removing PCI Card Guide TP02001 Rack Mount Kit Install Guide 3

7. Remove plastic filler panel from chassis by pushing on interior tab (see letter A in the following figure) and sliding filler panel towards rear of chassis (see letter B ). B A Figure 4. Removing Plastic Filler Panel from Chassis 8. Remove the three plastic plugs from left side of chassis. TP00959 TP02002 Figure 5. Removing Plastic Plugs 4 Rack Mount Kit Install Guide

9. Remove two screws from left and right sides of chassis. TP02003 Install Rack Handle Figure 6. Removing Rear Screws 10. Remove four plastic plugs from top side cover. TP02004 Figure 7. Removing Plastic Plugs from Top Side Cover Rack Mount Kit Install Guide 5

11. Install rack handle on left side cover using four 6-32 screws. TP01053 Figure 8. Installing Rack Handle on Left Side Cover 12. If removed, install front bezel assembly. Affix front panel label (see letter A in the following figure) to the front panel. A TP02005 Figure 9. Affixing Label to Front Panel 6 Rack Mount Kit Install Guide

13. Install top side cover on chassis. Warning: This chassis must be operated with the left side cover installed to ensure proper cooling. TP01057 Figure 10. Installing Top Side Cover on Chassis Rack Mount Kit Install Guide 7

Prepare Rack Rail Assembly 14. Detach inner rack rail from rack rail assembly. Press tab on inside of rack rail to release rack rail from rack rail assembly. TP02006 Figure 11. Detaching Inner Rack Rail from Rack Rail Assembly 8 Rack Mount Kit Install Guide

15. Attach inner rack rails (one per side) to chassis with four 6-32 screws. TP01052 Figure 12. Attaching Inner Rack Rails to Chassis Rack Mount Kit Install Guide 9

16. Attach outer rack rails to rack uprights. Ensure that the screws (two per outer rack rail; see letter A in the following figure) pass through the rack upright (see letter B ), and the outer rack rail (see letter C ). C A B TP01056 Figure 13. Attaching Outer Rack Rails to Rack Uprights 10 Rack Mount Kit Install Guide

Complete Setup 17. Install chassis into rack. Warning: Safe handling and lifting of this system requires TWO people. WARNING: Safe handling of this system requires TWO people. TP01058 Figure 14. Installing Chassis into Rack 18. Reconnect all peripheral devices and the AC power cable to the server. Power up the server. Rack Mount Kit Install Guide 11

12 Rack Mount Kit Install Guide