Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, and AXXRPFKSNSH Installation Guide
|
|
|
- Jordan Sharp
- 9 years ago
- Views:
Transcription
1 Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, and AXXRPFKSNSH Installation Guide Order Number: E E IMPORTANT: Your Intel RAID Controller must be programmed with the latest Intel RAID Controller firmware to enable Intel RAID Premium Features. Please check and verify that your Intel RAID Controller is programmed with the latest firmware. Current RAID controller firmware can be downloaded at If needed, please update your RAID controller before proceeding with any instructions in this installation guide.
2 Disclaimer Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright 2010 Intel Corporation. All Rights Reserved. ii Intel RAID Premium Feature Key Installation Guide
3 Important Safety Instructions Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See Intel Server Boards and Server Chassis Safety Information at Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel- Serverplatinen und -Servergehäusen unter 重 要 安 全 指 导 在 执 行 任 何 指 令 之 前, 请 阅 读 本 文 档 中 的 所 有 注 意 事 项 及 安 全 声 明 和 / 或 上 的 Intel Server Boards and Server Chassis Safety Information( Intel 服 务 器 主 板 与 服 务 器 机 箱 安 全 信 息 ) Important Safety InstructionsConsignes de sécurité Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information rendez-vous sur le site htm. Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en Intel RAID Premium Feature Key Installation Guide iii
4 WARNINGS Server power on/off: The push-button on/off power switch on the front panel of the server does not turn off the AC power. To remove AC power from the server, you must unplug the AC power cord from either the power supply or wall outlet. Hazardous conditions power supply: Hazardous voltage, current, and energy levels are present inside the power supply enclosure. There are no user-serviceable parts inside it; servicing should only be done by technically qualified personnel. Hazardous conditions devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect telecommunications systems, networks, modems, and the power cord attached to the server before opening it. Otherwise, personal injury or equipment damage can result. iv Intel RAID Premium Feature Key Installation Guide
5 Contents About Intel RAID Premium Feature Keys... 1 Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, or AXXRPFKSNSH Kit Contents... 1 Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, or AXXRPFKSNSH Requirements... 1 Installing the Hardware... 2 Install the Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, or AXXRPFKSNSH... 2 Finish Up the Hardware...3 Removing the Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, or AXXRPFKSNSH... 3 Intel RAID Premium Feature Introduction... 3 Intel RAID Premium Feature Key Installation Guide v
6 vi Intel RAID Premium Feature Key Installation Guide
7 About Intel RAID Premium Feature Keys Intel RAID Premium Feature Keys are used to enable premium RAID features on Intel RAID Controllers. Several Intel RAID Premium Feature Key models are available. This guide is specific to the Intel RAID Premium Feature Keys with the order code, AXXRPFKSSD, AXXRPFKDE, and AXXRPFKSNSH. The Feature key is designed to plug onto an Intel RAID Controller that has RAID Premium Feature Key connector on it. The Intel RAID Premium Feature Key must remain attached to the connector in order to enable the premium feature. RAID premium features enabled through the use of the key include SSD Cache with Fastpath, Encryption Management, and Snapshot. Please refer to the Intel RAID Software User s Guide on for more detailed information. Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, or AXXRPFKSNSH Kit Contents One Intel RAID Premium Feature Key (AXXRPFKSSD, AXXRPFKDE or AXXRPFKSNSH) These instructions Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, or AXXRPFKSNSH Requirements The Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE or AXXRPFKSNSH is the only hardware required to add the RAID Premium Feature to a selected Intel RAID Controller. Please refer to Intel RAID Software User s Guide on for the list of Intel RAID Controllers that are supported by the Intel RAID Premium Feature Keys. Intel RAID Premium Feature Key Installation Guide 1
8 Installing the Hardware Install the Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, or AXXRPFKSNSH 1. Carefully remove the RAID Premium Feature Key from its packaging. 2. Locate the RAID Premium Feature Key connector on the Intel RAID Controller. This is a 2- pin shielded connector. The following figure shows the location of the RAID Premium Feature Key connector on the Intel RAID Controller RS2BL080. In the figure, the arrow points to the location of the RAID Premium Feature Key connector. The location of RAID Premium Feature Key connector on your Intel RAID Controller may vary. Please refer to the User Guide for your Intel RAID Controller for the location of this connector. Figure 1. Locating RAID Premium Feature Key connector on Intel RAID Controller RS2BL With the 2-hole edge of the RAID Premium Feature key pointing to the RAID Premium Feature Key 2-pin connector of the RAID controller, push the key onto the connector on the RAID controller. 2 Intel RAID Premium Feature Key Installation Guide
9 Figure 2. Installing RAID Premium Feature Key on Intel RAID Controller RS2BL080 Finish Up the Hardware 1. Refer to documentation of the Intel RAID Controller from to finish installing the RAID controller into an Intel Server Board, or qualified third party server board. Removing the Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, or AXXRPFKSNSH 1. Follow steps in documentation of the Intel RAID Controller to remove the RAID controller from server board. 2. Firmly hold the RAID controller on table, and pull the Intel RAID Premium Feature Key from the connector. Intel RAID Premium Feature Introduction This section introduces Intel RAID Premium Features that can be enabled by the Intel RAID Premium Feature Key. For details on how to use above features, please refer to Intel RAID Intel RAID Premium Feature Key Installation Guide 3
10 Software User s Guide which can be downloaded at Intel RAID Premium Feature Key AXXRPFKSSD enables a form of Flash Tiering called SSD Cache and Fastpath features. SSD Cache uses Solid State Devices as secondary cache for Intel RAID Controllers and is designed to improve read performance of Intel RAID Controller. Fastpath feature can support full optimization of SSD Virtual Disk groups. With this premium feature enabled, Solid State Drive configurations tuned for small, random blocksize IO activity (typical of transactional database applications) can sustain up to over 150,000 IO READS Per Second. Note: The Fastpath feature is automatically enabled when the Intel RAID Premium Feature Key AXXRPFKSSD is present. Intel RAID Premium Feature Key AXXRPFKDE enables Full Disk Encryption feature. This feature enables the Intel RAID Controller to manage data security protection for Self Encrypting Drives (SED). Intel RAID Premium Feature Key AXXRPFKSNSH enables the Snapshot feature. This feature automatically creates snapshots for stored data on a scheduled basis. Lost data could be restored from a known good previous snapshot. With the Feature Key installed, unless noted specifically, the added feature must be enabled and/or configured using the RAID BIOS Console utility or RAID Web Console 2 utility. For detailed information on enabling and configuring the feature key option, please refer to the Intel RAID Software User s Guide available under your selected controller at 4 Intel RAID Premium Feature Key Installation Guide
4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System
4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System Order Number: G23758-002 G23758-002 This document provides instructions for installing the following accessory kit: FUP4X35HSDK
Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S
Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number: E13860-004 Disclaimer Information
Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP
Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products
Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products
Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number: E12567-002 Disclaimer Information
Intel RAID Maintenance Free Backup Unit AXXRMFBU2 User s Guide
Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products Intel Order Number: G49043-005 Disclaimer Information
Recovery BIOS Update Instructions for Intel Desktop Boards
Recovery BIOS Update Instructions for Intel Desktop Boards All BIOS update files for Intel Desktop Boards are available on Intel's Download Center at http://downloadcenter.intel.com/. Important Notes:
This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.
Installation Guide This guide explains how to install an (Intel SSD) in a SATA-based desktop or notebook computer. The instructions include migrating your data from your current storage device (such as
Trusted Platform Module (TPM) Quick Reference Guide
Trusted Platform Module (TPM) Quick Reference Guide System builders/integrators should give this Guide to the system owners to assist them in enabling and activating the Trusted Platform Module. Warning
Intel RAID Controller Premium Feature Key Training
Intel RAID Controller Premium Feature Key Training AXXRPFKSNSH Snapshot Recovery AXXRPFKDE Self Encrypting Drive (SED) AXXRPFKSSD SSD Cache with Fastpath Note: Graphics for this training is based on RAID
Intel RAID Controller Troubleshooting Guide
Intel RAID Controller Troubleshooting Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Intel order number C18781-001 September 2, 2002 Revision History Troubleshooting
Intel Data Migration Software
User Guide Software Version 2.0 Document Number: 324324-002US INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY
Intel RAID Web Console 2 and StorCLI Command Line Tool
SOLUTIONS Brief Intel RAID Web Console 2 and StorCLI Command Line Tool Powered by LSI* MegaRAID technology Instant access, intuitive configuration/navigation, easy standard storage management and advanced
Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures
Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures For Intel Server RAID Controller U3-1 and Intel Server RAID Controller U3-1L Revision 1.1 12/21/01 Date Rev Modifications 12/21/01 1.1
Trusted Platform Module (TPM) Quick Reference Guide
Trusted Platform Module (TPM) Quick Reference Guide System builders/integrators should pass this Guide on to the system owner to assist them in enabling and activating the TPM. Warning of Potential Data
Intel Matrix Storage Console
Intel Matrix Storage Console Reference Content January 2010 Revision 1.0 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE,
Intel Remote Management Module User s Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products
Intel Remote Management Module User s Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number D48601-001 Disclaimer Information in this document
Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide
Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Thank you for buying an Intel RAID Maintenance Free Backup Unit 4. The Intel RAID Maintenance Free Backup Unit 4 supports the Intel
Intel RAID Volume Recovery Procedures
Intel RAID Volume Recovery Procedures Revision 1.0 12/20/01 Revision History Date Revision Number 12/20/01 1.0 Release Modifications Disclaimers Information in this document is provided in connection with
Intel Entry Storage System SS4000-E
Intel Entry Storage System SS4000-E Software Release Notes March, 2006 Storage Systems Technical Marketing Revision History Intel Entry Storage System SS4000-E Revision History Revision Date Number 3 Mar
StorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3
Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3 Author: Conor Malone, VP Engineering, Hyve Solutions 1 Scope This document discusses the requirements and specifications
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide Thank you for buying an Intel RAID Module. Your Intel RAID Module provides reliability,
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
Instructions for Recovery BIOS Update
Instructions for Recovery BIOS Update In the unlikely event that a BIOS update is interrupted, it is possible the BIOS may be left in an unusable state. The recovery process requires the chassis to be
Intel Storage Server SSR212MC2/ SSR212MC2R User Guide
Intel Storage Server SSR212MC2/ SSR212MC2R User Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number D90842-002 Disclaimer Information in this
Intel SSD 520 Series Specification Update
Intel SSD 520 Series Specification Update June 2012 Revision 1.0 Document Number: 327567-001US INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Intel RAID Controllers
Intel RAID Controllers Best Practices White Paper April, 2008 Enterprise Platforms and Services Division - Marketing Revision History Date Revision Number April, 2008 1.0 Initial release. Modifications
Intel Technical Advisory
This Technical Advisory describes an issue which may or may not affect the customer s product Intel Technical Advisory 5200 NE Elam Young Parkway Hillsboro, OR 97124 TA-1054-01 April 4, 2014 Incorrectly
Intel Desktop Board D925XECV2 Specification Update
Intel Desktop Board D925XECV2 Specification Update Release Date: July 2006 Order Number: C94210-005US The Intel Desktop Board D925XECV2 may contain design defects or errors known as errata, which may cause
Intel RAID Maintenance Free Backup Unit AXXRMFBU2 User s Guide
Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products Intel Order Number: G49043-004 Disclaimer Information
Configuring RAID for Optimal Performance
Configuring RAID for Optimal Performance Intel RAID Controller SRCSASJV Intel RAID Controller SRCSASRB Intel RAID Controller SRCSASBB8I Intel RAID Controller SRCSASLS4I Intel RAID Controller SRCSATAWB
Intel Storage System SSR212CC Enclosure Management Software Installation Guide For Red Hat* Enterprise Linux
Intel Storage System SSR212CC Enclosure Management Software Installation Guide For Red Hat* Enterprise Linux Order Number: D58855-002 Disclaimer Information in this document is provided in connection with
Intel RAID RS25 Series Performance
PERFORMANCE BRIEF Intel RAID RS25 Series Intel RAID RS25 Series Performance including Intel RAID Controllers RS25DB080 & PERFORMANCE SUMMARY Measured IOPS surpass 200,000 IOPS When used with Intel RAID
Intel Server System S7000FC4UR
Intel Server System S7000FC4UR Power Cord Enabling Specification January, 2007 Enterprise Platforms and Services Division - Marketing Intel Server System S7000FC4UR Power Supply Specification Revision
Intel Matrix Storage Manager 8.x
Intel Matrix Storage Manager 8.x User's Manual January 2009 Revision 1.0 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Intel Desktop Board D101GGC Specification Update
Intel Desktop Board D101GGC Specification Update Release Date: November 2006 Order Number: D38925-003US The Intel Desktop Board D101GGC may contain design defects or errors known as errata, which may cause
Intel Server Raid Controller. RAID Configuration Utility (RCU)
Intel Server Raid Controller RAID Configuration Utility (RCU) Revision 1.1 July 2000 Revision History Date Rev Modifications 02/13/00 1.0 Initial Release 07/20/00 1.1 Update to include general instructions
Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
Intel RAID Premium Features
Intel RAID Premium Features Description and use Revision 1.0 August, 2010 Enterprise Platforms and Services Division - Marketing Revision History Intel RAID Premium Features Revision History Date Revision
Intel Server Board S5520HC, S5520HCT and S5500HCV Service Guide
Intel Server Board S5520HC, S5520HCT and S5500HCV Service Guide Order Number: E39527-008 Revision 1.4 Disclaimer Disclaimer Information in this document is provided in connection with Intel products. No
MultiVOIP FX SIP Gateways
MultiVOIP FX SIP Gateways MVPFX2-2 MVPFX2-4 MVPFX2-8 Cabling Guide Cabling Guide MultiVOIP FX SIP Gateways, Models MVPFX2-2, MVPFX2-4, MVPFX2-8 82100090L Rev. A Copyright This publication may not be reproduced,
Intel Desktop Board DP55WB
Intel Desktop Board DP55WB Specification Update July 2010 Order Number: E80453-004US The Intel Desktop Board DP55WB may contain design defects or errors known as errata, which may cause the product to
HP SATA/SAS hard drive and Solid State Drive installation
HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal
RAID Basics Training Guide
RAID Basics Training Guide Discover a Higher Level of Performance RAID matters. Rely on Intel RAID. Table of Contents 1. What is RAID? 2. RAID Levels RAID 0 RAID 1 RAID 5 RAID 6 RAID 10 RAID 0+1 RAID 1E
Dell Spotlight on Active Directory 6.8.3. Server Health Wizard Configuration Guide
Dell Spotlight on Active Directory 6.8.3 Server Health Wizard Configuration Guide 2013 Dell Software Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software
Intel Active Management Technology with System Defense Feature Quick Start Guide
Intel Active Management Technology with System Defense Feature Quick Start Guide Introduction...3 Basic Functions... 3 System Requirements... 3 Configuring the Client System...4 Intel Management Engine
Intel Server System P4000RP Family Service Guide A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products
Intel Server System P4000RP Family Service Guide A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products Order Number: G89704-001 Disclaimer Disclaimer INFORMATION IN THIS
with PKI Use Case Guide
Intel Identity Protection Technology (Intel IPT) with PKI Use Case Guide Version 1.0 Document Release Date: February 29, 2012 Intel IPT with PKI Use Case Guide i Legal Notices and Disclaimers INFORMATION
Intel Compute Stick STCK1A32WFC User Guide. Intel Compute Stick STCK1A32WFC
Intel Compute Stick STCK1A32WFC User Guide 1 Revision History Revision Revisions History Date 01 First release of the Intel Compute Stick STCK1A32WFC User Guide April 2015 Disclaimer INFORMATION IN THIS
Intel Desktop Board D945GCL
Intel Desktop Board D945GCL Specification Update December 2007 Order Number D74277-004US The Intel Desktop Board D945GCL may contain design defects or errors known as errata, which may cause the product
Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: 121312 PN: 883884-35L Rev. A
Installation Guide Wyse D Class 4-GB RAM Upgrade Option Kit Products: D90D7, D90DW Issue: 121312 PN: 883884-35L Rev. A Copyright Notices 2012, Wyse Technology Inc. All rights reserved. This manual and
SSD Firmware Update Utility Guide
SSD Firmware Update Utility Guide Crucial m4 2.5 SSD Firmware Revision 070H Firmware Update Guide for Windows 8 (Update from Rev 0001, 0002, 0009, 0309, 000F, 010G, 040H to Rev 070H) Introduction This
ServeRAID M5000 Series Performance Accelerator Key for IBM System x Product Guide
ServeRAID M5000 Series Performance Accelerator Key for IBM System x Product Guide The ServeRAID M5000 Series Performance Accelerator Key for System x enables performance enhancements needed by emerging
Intel Desktop Board DG965RY
Intel Desktop Board DG965RY Specification Update May 2008 Order Number D65907-005US The Intel Desktop Board DG965RY contain design defects or errors known as errata, which may cause the product to deviate
Installation Guide Universal Wireless-n Adapter GWU627 PART NO. M1161
Installation Guide Universal Wireless-n Adapter GWU627 PART NO. M1161 Table of Contents Package Contents 4 System Requirements 5 Product Overview 6 Installation 8 Installation without WPS - Windows XP
Intel Desktop Board D945GCPE Specification Update
Intel Desktop Board D945GCPE Specification Update Release Date: July 11, 2007 Order Number: E11670-001US The Intel Desktop Board D945GCPE may contain design defects or errors known as errata, which may
Power Supply Guide Version 1.0 for D-Show
Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731
Intel Rapid Storage Technology
Intel Rapid Storage Technology User Guide August 2011 Revision 1.0 1 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Intel RAID. INTEL raid
Intel RAID Intel offers multiple categories of RAID products to protect data, increase performance, scale storage, and enhance server availability. A brief description of each category is listed below
Intel Desktop Board D945GCZ
Intel Desktop Board D945GCZ Specification Update December 2007 Order Number D23991-007US The Intel Desktop Board D945GCZ may contain design defects or errors known as errata, which may cause the product
Intel Desktop Board DG33TL
Intel Desktop Board DG33TL Specification Update May 2008 Order Number E11661-003US The Intel Desktop Board DG33TL may contain design defects or errors known as errata, which may cause the product to deviate
Intel vpro Technology. How To Purchase and Install Symantec* Certificates for Intel AMT Remote Setup and Configuration
Intel vpro Technology How To Purchase and Install Symantec* Certificates for Intel AMT Remote Setup and Configuration Document Release Date: September 14, 2012 Revision History Revision Revision History
MultiVOIP FX FXS-Only SIP Gateways
MultiVOIP FX FXS-Only SIP Gateways MVPFXS-8 MVPFXS-16 MVPFXS-24 Cabling Guide MultiVOIP MVPFXS-8/16/24 Cabling Guide Cabling Guide MultiVOIP FX SIP FXS-Only Gateways Models MVPFXS-8, MVPFXS-16, MVPFXS-24
Intel Desktop Board DQ35JO
Intel Desktop Board DQ35JO Specification Update May 2008 Order Number E21492-002US The Intel Desktop Board DQ35JO may contain design defects or errors known as errata, which may cause the product to deviate
Intel RAID SSD Cache Controller RCS25ZB040
SOLUTION Brief Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters Cost-Effective Intelligent RAID with Embedded High Performance Flash Intel RAID SSD Cache Controller RCS25ZB040 When Faster
USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices
USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices White Paper April 2012 Document: 327216-001 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,
Intel Server Board Platform Confidence Test Installation and Operating Instructions
Intel Server Board Platform Confidence Test Installation and Operating Instructions i Intel Corporation 2002-2009 Information in this document is provided in connection with Intel products. No license,
Intel Desktop Board DQ965GF
Intel Desktop Board DQ965GF Specification Update October 2008 Order Number: D65914-005US The Intel Desktop Board DQ965GF may contain design defects or errors known as errata, which may cause the product
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
Intel Core i5 processor 520E CPU Embedded Application Power Guideline Addendum January 2011
Intel Core i5 processor 520E CPU Embedded Application Power Guideline Addendum January 2011 Document Number: 324818-001 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,
Intel Media SDK Library Distribution and Dispatching Process
Intel Media SDK Library Distribution and Dispatching Process Overview Dispatching Procedure Software Libraries Platform-Specific Libraries Legal Information Overview This document describes the Intel Media
Intel Desktop Board D945GNT
Intel Desktop Board D945GNT Specification Update Release Date: November 2007 Order Number: D23992-007US The Intel Desktop Board D945GNT may contain design defects or errors known as errata, which may cause
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
User Experience Reference Design
Use McAfee* Real Time Command and Intel SCS 9 to Manage Intel SSD Professional 1500 Series Drives Revision 1.1 July 2014 Document number: 330798-001 Revision History Revision Revision History Date 1.0
System Event Log (SEL) Viewer User Guide
System Event Log (SEL) Viewer User Guide For Extensible Firmware Interface (EFI) and Microsoft Preinstallation Environment Part Number: E12461-001 Disclaimer INFORMATION IN THIS DOCUMENT IS PROVIDED IN
WHITE PAPER. LVDS Flat Panel Display Interface on Intel Desktop Boards. July 2009 Order Number: E77911-001
WHITE PAPER LVDS Flat Panel Display Interface on Intel Desktop Boards July 2009 Order Number: E77911-001 Revision History Revision Revision History Date 1.0 Initial release of the LVDS Flat Panel Interface
Intel Management Engine BIOS Extension (Intel MEBX) User s Guide
Intel Management Engine BIOS Extension (Intel MEBX) User s Guide User s Guide For systems based on Intel B75 Chipset August 2012 Revision 1.0 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide 49760-00, Revision A January 2011 49760-00A Revision History Version and Date 49760-00 Rev. A, January 2011 Initial release of
Enclosure Management Cabling Guide for Intel C200 and C600 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures
Enclosure Management Cabling Guide for Intel C200 and C600 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures Cabling Guide for: Intel C200 or C600 Series Chipset based Server Boards and
Small form factor bay converter and hard drive installation
Small form factor bay converter and hard drive installation HP xw6600 and HP xw8600 Workstations This document describes how to convert HP xw6600 and HP xw8600 Workstation 3.5-inch hard drive bays to hold
Dell One Identity Cloud Access Manager 8.0 - How to Configure vworkspace Integration
Dell One Identity Cloud Access Manager 8.0 - How to Configure vworkspace Integration February 2015 This guide describes how to configure Dell One Identity Cloud Access Manager to communicate with a Dell
User Guide Software Version 2.1.0
Intel Solid State Drive Firmware Update Tool User Guide Software Version 2.1.0 Order Number: 322570-007US Intel disclaims all express and implied warranties, including without limitation, the implied warranties
Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA
Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA Important Safety Messages Read the instructions carefully to become familiar with the equipment before trying to install, operate, service
Intel vpro Technology. How To Purchase and Install Go Daddy* Certificates for Intel AMT Remote Setup and Configuration
Intel vpro Technology How To Purchase and Install Go Daddy* Certificates for Intel AMT Remote Setup and Configuration Revision 1.4 March 10, 2015 Revision History Revision Revision History Date 1.0 First
P O W E R S U P P L Y M A N U A L
POWER SUPPLY MANUAL Congratulations on the purchase of your new Corsair power supply. This User Agreement (the Agreement ) is a legal agreement between you ( You ), and Corsair Memory, Inc. ( Corsair ).
Intel Desktop Board D945GCPE
Intel Desktop Board D945GCPE Specification Update January 2009 Order Number: E11670-003US The Intel Desktop Board D945GCPE may contain design defects or errors known as errata, which may cause the product
UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M5 13 8 To mount outer member to rack
UPDATEUPDATEUPDATE Converting the tower chassis to a rack-mount chassis Rail overview Converting your Server to Rack-Mount The rail kit includes the following: Two rail units Five packages of screws (labeled
FUSION R400 RAID USB 3.0
FUSION R400 RAID USB 3.0 1U Rackmount 4-Drive Hardware RAID 5 SATA Storage System with USB 3.0 Interface User s Guide For Windows Contents 1 Fusion R400 RAID USB 3.0 Features 1 2 Drive Installation and
Meter Test-Socket Adapter
Introduction There are different test-socket adapters for the Form 5 and Form 9 SEL-734 and SEL-735 meters. The kit numbers needed for ordering are listed below. Installation SEL-734 and SEL-735 Form 5
Intel Solid-State Drive Pro 2500 Series Opal* Compatibility Guide
Opal* Compatibility Guide 1.0 Order Number: 331049-001US INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL
Intel System Event Log (SEL) Viewer Utility
Intel System Event Log (SEL) Viewer Utility User Guide Document No. E12461-003 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE GENERAL PURPOSE OF SUPPORTING
Installation Guide. Wyse D Class, Wyse X Class, and Wyse Z Class Flash Upgrade Option Kit
Installation Guide Wyse D Class, Wyse X Class, and Wyse Z Class Flash Upgrade Option Kit Products: D90D7, D90DW, X90m7, X90mw, Z90D7, Z90S7, Z90DW, Z90SW Issue: 011613 PN: 883884-31L Rev. B Copyright Notices
4 Processor/4U-P System. Information Update
4 Processor/4U-P System Information Update Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either potential
Intel Desktop Board DG43RK
Intel Desktop Board DG43RK Specification Update December 2010 Order Number: E92421-003US The Intel Desktop Board DG43RK may contain design defects or errors known as errata, which may cause the product
Thin Mini-ITX Component Catalog Q3, 2012
Thin Mini-ITX Component Catalog Q3, 2012 Introduction Introducing All-In-One PCs All-In-One PCs combine compelling design with support for a wide range of computing components. Integrate the appropriate
Executive Series. Intel Desktop Board DB75EN Executive Series MicroATX Form Factor
Intel Desktop Board DB75EN MicroATX Form Factor product brief Built for Business: Intel Desktop Board DB75EN maximizes employee productivity, PC performance, and data security with Intel Small Business
Intel Server System SR1625UR Service Guide
Intel Server System SR1625UR Service Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number E52881-005 Disclaimer Information in this document
Resetting USB drive using Windows Diskpart command
Resetting USB drive using Windows Diskpart command Simon Huang Technical Product Manager [email protected] Super Talent Technology October, 2013 Release 1.00 1 Legal Disclaimer INFORMATION IN