Intel RAID Maintenance Free Backup Unit AXXRMFBU2 User s Guide
|
|
|
- Noel Ryan
- 10 years ago
- Views:
Transcription
1 Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products Intel Order Number: G
2 Disclaimer Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel s Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice. Intel server boards contain a number of high-density VLSI and power delivery components that need adequate airflow for cooling. Intel s own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits. Intel, Intel Pentium, and Intel eon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright 2013 Intel Corporation. All Rights Reserved. Copyright LSI* Corporation. All Rights Reserved. Intel warranties that this product will perform to its published specifications. However, all computer systems are inherently subject to unpredictable system behavior under various environmental and other conditions. This product is not intended to be the sole source for any critical data and the user must maintain a verified backup. Failure to do so or to comply with other user notices in the product user guide and specification documents may result in loss of or access to data. ii Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
3 Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel Server Deployment Toolkit 3.0 CD and/or at Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel - Serverplatinen und Servergehäusen auf der Intel Server Deployment Toolkit 3.0 CD oder unter Consignes de sécurité Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel Server Deployment Toolkit 3.0 CD ou bien rendez-vous sur le site Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel Server Deployment Toolkit 3.0 CD y/o en 重 要 安 全 指 导 在 执 行 任 何 指 令 之 前, 请 阅 读 本 文 档 中 的 所 有 注 意 事 项 及 安 全 声 明 和 / 或 上 的 Intel Server Boards and Server Chassis Safety Information( Intel 服 务 器 主 板 与 服 务 器 机 箱 安 全 信 息 ) Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide iii
4 Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products/components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold. System power on/off: The power button DOES NOT turn off the system AC power. To remove power from the system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components. Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result. Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts. ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. iv Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
5 Table of Contents 1 About the Intel RAID Maintenance Free Backup Unit ARMFBU Installing the Hardware...2 Remote Connecting Cables... 2 Important Pre-installation Considerations... 3 Installing the Intel RAID Maintenance Free Backup Unit ARMFBU Removing the RAID Module... 3 Installing the Intel RAID Maintenance Free Backup Unit ARMFBU Connecting the Plastic RMFBU2 Holder to the Chassis... 6 Attaching the Connecting Cable to the Server System... 6 Installing the Intel Integrated RAID Module in the Server System Monitoring RAID Maintenance Free Backup Unit...9 Monitoring the SuperCap with the Intel RAID BIOS Configuration Utility... 9 Using Intel RAID Web Console RAID Maintenance Free Backup Unit Specifications MegaRAID CacheVault TM Technology Regulatory and Compliance Information Product Regulatory Compliance Product Safety Compliance Product EMC Compliance Class A Compliance Certifications/Registrations/Declarations Product Regulatory Compliance Markings Electromagnetic Compatibility Notices FCC (USA) Industry Canada (ICES-003) Europe (CE Declaration of Conformity) Taiwan Declaration of Conformity (BSMI) Korean Compliance (RRL) Intel Server Issue Report Form Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide v
6 List of Figures Figure 1. Top View of the Intel RAID Maintenance Free Backup Unit ARMFBU Figure 2. Connecting ARMFBU2 to the RAID Module... 4 Figure 3. Connect the cable... 5 Figure 5. Connecting the Plastic RMFBU2 Holder to the Chassis... 6 Figure 6. Seating the RAID Module... 7 Figure 7. Tie Together the Cables with the Strap Tie... 7 Figure 8. Installing the Barrel Standoff... 8 Figure 9. Installing the Intel Integrated RAID Module... 8 Figure 10. Monitoring the RMFBU2 with Intel RAID BIOS Console... 9 Figure 11. RMFBU2 Information in Intel RAID Web Console vi Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
7 List of Tables Table 1. Cable Compatibility... 2 Table 2. RMFBU2 Specifications Table 3. Product Certification Markings Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide 1
8 1 About the Intel RAID Maintenance Free Backup Unit ARMFBU2 Intel Integrated RAID (Redundant Array of Inexpensive Disks) Modules provide reliability, high performance, and fault-tolerant disk subsystem management. A complete fault-tolerant strategy requires protection of all data, including the unwritten cached data in the RAM cache. If power is lost, the data in the RAM cache is lost. To avoid data loss, a RAID Maintenance Free Backup Unit (RMFBU) can be added to store unwritten cached data from the RAID RAM during an AC power outage or if the AC power cord is removed. A RAID Maintenance Free Backup Unit protects the integrity of the cached data on Intel Integrated RAID Modules by offloading data stored in the RAM cache to the NAND flash if there is a complete AC power failure or a brief power outage. The Intel RAID Maintenance Free Backup Unit provides an alternative to use an uninterruptible power supply (UPS) or it can act as a second level of fault tolerance when used with a UPS. Furthermore, it eliminates the need for lithium ion (Li-ion) batteries traditionally used to protect DRAM cache memory on PCI RAID controllers. Therefore this is a greener and lower total cost cache protection solution. The cache memory available on Intel Integrated RAID Modules can improve the overall system performance. Writing data to the controller s cache memory is much faster than writing it to a storage device. Write operations appear to complete very quickly at the software application level. The Intel Integrated RAID Module writes the cached data to the storage device when system activity is low or when the cache is getting full. The risk of using writeback cache is that the cached data can be lost if the AC power fails before it is written to the storage device. This risk factor is eliminated when the Intel Integrated RAID Module has a RMFBU installed. The Intel RAID Maintenance Free Backup Unit ARMFBU2 consists of Cache Offload Module and SuperCap2. It monitors the voltage level of the DRAM modules of the Intel Integrated RAID Module. If the voltage drops below a predefined level, the RMFBU offloads the data from the RAID RAM to the NAND flash of RMFBU2 Cache-offload Module and SuperCap2 provides sufficient power to complete the data transferring. When the voltage level returns to an acceptable level, the RAID RAM is recovered from flash, and all pending writes to storage devices are completed without losing any data. The Intel RAID Maintenance Free Backup Unit ARMFBU2 has a built-in functionality to charge the SuperCap2 automatically and to communicate entire unit status information such as voltage, temperature, and current to the host server system. The Intel RAID Maintenance Free Backup Unit ARMFBU2 is a smart backup module and uses MegaRAID CacheVault Technology. It is compatible with a backup auxiliary power source. The SuperCap2 is charged automatically. Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide 1
9 2 Installing the Hardware The Intel RAID Maintenance Free Backup Unit ARMFBU2 pack attaches to the RAID modules remotely. Figure 1 displays the top view of the Intel RAID Maintenance Free Backup Unit ARMFBU2. The 26-pin connector (see letter A for the location of this connector) is used to remotely connect to an Intel Integrated RAID module using the supplied cable. Figure 1. Top View of the Intel RAID Maintenance Free Backup Unit ARMFBU2 Remote Connecting Cables Two 26-pin to 30-pin RMFBU2 Cache-offload Module cables (20-inch and 40-inch) are provided in the ARMFBU2 kit to remotely connect the Intel RAID Maintenance Free Backup Unit ARMFBU2 to the Intel Integrated RAID Module. Table 1. Cable Compatibility Intel RAID Controller or Server System 20-inch Cable 40-inch Cable Intel Integrated RAID Module RMS25PB080 Intel Integrated RAID Module RMS25PB040 Intel Integrated RAID Module RMT3PB080 Intel Integrated RAID Module RMS25CB080 Intel Integrated RAID Module RMS25CB040 Intel Integrated RAID Module RMT3CB080 Intel pedestal chassis Intel rack mount chassis 2 Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
10 Important Pre-installation Considerations Warning: Make sure that you are grounded and/or use a ground strap before touching the RAID module or the Intel RAID Maintenance Free Backup Unit ARMFBU2. Perform all installation work at and ESD-safe workstation. Use an ESD-safe Phillips* screwdriver set to a maximum torque of 2.25 inch-pounds, and be sure the screwdriver is centered in the screw to avoid damaging the screw head. If you exceed the maximum torque specification, you may damage the board, connectors, or screws, and you will void the warranty of the board. Installing the Intel RAID Maintenance Free Backup Unit ARMFBU2 Warning: After the Intel RAID Maintenance Free Backup Unit ARMFBU2 is installed, do not disconnect it from the Intel Integrated RAID Module RMS25PB080, RMS25PB040, RMT3PB080, RMS25CB080, RMS25CB040, or RMT3CB080 when system has an unclean shutdown (that is, AC lost during operating system is running). Doing so will cause ARMFBU2 unrecoverable failure and replacement is required. To install the Intel RAID Maintenance Free Backup Unit ARMFBU2 on the Intel Integrated RAID Module, you must perform the following steps: 1. Remove the RAID Module if it is already installed in the server system. For information, see Removing the RAID Module. 2. Install Intel RAID Maintenance Free Backup Unit ARMFBU2 on the RAID Module using the following method: Set up a remote connection through the remote RMFBU connector. For information, see Installing the Intel RAID Maintenance Free Backup Unit ARMFBU2. 3. Install the RAID Module in the server system. For information, see Installing the Intel Integrated RAID Module in the Server System. Removing the RAID Module If the RAID module is already installed in a system, do the following to remove it before you install the Intel RAID Maintenance Free Backup Unit ARMFBU2: 1. Shutdown the system. Turn off the power and unplug the power cord(s). 2. Remove the chassis cover. Make sure that you are grounded before touching the RAID module. Carefully unplug all cables connected to the RAID module. 3. Carefully remove the RAID module from the server board. For more information on removing Intel Integrated RAID module, refer to Quick Start User s Guide shipped with Intel Integrated RAID module. 4. Place the RAID controller on a flat, clean, static-free surface. Installing the Intel RAID Maintenance Free Backup Unit ARMFBU2 A remote connection to the RAID module is required. To install the Intel RAID Maintenance Free backup Unit ARMFBU2 on the RAID Module through 26-pin connector, do the following: Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide 3
11 1. Make sure that you are grounded and take the Intel RAID Maintenance Free backup Unit ARMFBU2 out of the package. 2. Verify that the RMFBU2 Cache Offload Module and SuperCap2 are installed in the plastic bracket already. 3. Select a suitable cable from two cables provided for your system. 4. Carefully and lightly grasp the base of the cable. Make sure the yellow pin 1 of the cable is in alignment with the yellow mark on the board connector. Press the connector with your finger and insert with the connector parallel. Figure 2. Connecting ARMFBU2 to the RAID Module 4 Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
12 Note: Carefully observe how the cable connectors are keyed and avoid asserting unnecessary force when plugging in the cable. Do not insert at an angle. Doing so will cause connector deformation or damage. Warning: 1. Make sure the yellow pin 1 of the cable is in alignment with the yellow mark on the board connector. Press the connector with your finger and insert with the connector parallel (see A in Figure 3). Do not try to insert cable backwards. Doing so will cause damage to the Intel RAID Maintenance Free backup Unit ARMFBU2 and Intel Integrated RAID Module. 2. Do not insert at an angle. Doing so will cause connector deformation or damage, even hardware damage to the Intel RAID Maintenance Free backup Unit ARMFBU2 and Intel Integrated RAID Module (see B in Figure 3). Figure 3. Connect the cable 5. Secure the cable at 26-pin end with a provided Cable Twist Tie as shown in Figure 4. Note: This step is optional depends on the chassis design. Please refer to your server chassis documentation to determine if the Cable Twist Tie is needed. Figure 4. Installing the Cable Twist Tie Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide 5
13 Connecting the Plastic RMFBU2 Holder to the Chassis The Intel RAID Maintenance Free Backup Unit ARMFBU2 is designed for easy attachment to either an Intel pedestal or rack mount chassis. Complete the following instructions for your server. If you are installing this component into a third-party chassis, you must first install an attachment mechanism, such as industrial-grade Velcro*. Refer to your server chassis documentation or discuss an appropriate attachment mechanism with your server chassis manufacturer to ensure the attachment mechanism complies with the chassis requirements. 1. Locate the installation clips inside the chassis. For the location of the installation clips, see your server system documentation. Remove the Mylar* pad if there is a Mylar* pad covering the mounting hole. 2. Align the tabs on the plastic RMFBU2 holder with the clips on the chassis (See A in Figure 5). 3. Slide the plastic RMFBU2 holder toward the front of the system until the tabs engage with the clips in the chassis (See B in Figure 5). Figure 5. Connecting the Plastic RMFBU2 Holder to the Chassis Attaching the Connecting Cable to the Server System Follow the appropriate set of instructions below for your server: 1. Route the cable through the cable holder on the edge of the chassis. 2. Connect the cable to the RAID module. Installing the Intel Integrated RAID Module in the Server System To install the Intel Integrated RAID Module back into the server system, do the following: Intel Integrated RAID Module RMS25PB040, RMS25PB080, RMT3PB Align the RAID module with the PCI Express* slot. To locate an appropriate slot and for instructions on installing an add-in card, see your server system documentation. 2. Press down gently, but firmly, to ensure that the RAID module is properly seated in the slot. The bottom edge of the RAID module must be flushed with the slot. 6 Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
14 Figure 6. Seating the RAID Module 3. Connect the proper cables into the adapter using the 4-port combined end. Make sure the module and cables are properly attached and plug the cable into connector at the inside edge of the adapter. 4. Tie the RMFBU2 Cache-offload Module cable and the data cable together with a strap tie that is provided, as shown in Figure 7. Figure 7. Tie Together the Cables with the Strap Tie Note: Please secure the cables with the strap tie to avoid unexpected RMFBU2 Cache-offload Module cable detaching from the RAID module during the system transportation. 5. Install the server system cover back and connect the power cords. See your server system documentation for instructions. Intel Integrated RAID Module RMS25PB040, RMS25PB080, RMT3PB Insert the four barrel standoffs into the matching holes in the server board. To locate the matching module card slot on your server board, see your server board documentation. The Intel Server Board S2600IP is shown for illustrative purpose. Actual standoff hole locations could be different (see Figure 8). Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide 7
15 Figure 8. Installing the Barrel Standoff 2. Attach the RAID to the matching server board connector, and press the module card firmly to engage the barrel standoffs installed in step 1. Press down gently but firmly to ensure that the card is properly seated in the connectors, and then insert the four pin standoffs into the barrel standoffs respectively. The Intel RAID Module RM25PB080 is shown for illustrative purpose (see Figure 9). Figure 9. Installing the Intel Integrated RAID Module 3. Connect the proper cables into the adapter using the 4-port combined end. Make sure the module and cables are properly attached and plug the cable into connector at the inside edge of the adapter. 4. Tie together the RMFBU2 Cache-offload Module cable and the data cable with a provided strap tie as shown in Figure 7. Note: Please secure the cables with the strap tie to avoid unexpected RMFBU2 Cacheoffload Module cable detaching from the RAID module during the system transportation. 5. Install the server system cover back and connect the power cords. See your server system documentation for instructions. 8 Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
16 3 Monitoring RAID Maintenance Free Backup Unit Multiple utilities are available to display and configure the RMFBU2 information. Note: This chapter describes only the RMFBU2 related features of the utility programs. For complete information on these utilities, see the Intel RAID Software User s Guide. Monitoring the SuperCap with the Intel RAID BIOS Configuration Utility The Intel RAID BIOS Console can be used to configure disk arrays and logical drives. It is independent of the operating system and can be accessed at server start up by pressing <Ctrl>+<G>. To view the RMFBU2 information, do the following: 1. At boot, press <Ctrl> + <G> when prompted. 2. Once the Intel RAID BIOS Console loads and the main menu is displayed, choose Adapter Properties. 3. Click Next to view the second Adapter Properties screen. 4. In the Battery Backup field at the top left of the Adapter Properties screen, click Present. 5. The Battery Module screen appears, as shown in Figure 10. This screen contains the following information: Battery information Design information Capacity information Properties Figure 10. Monitoring the RMFBU2 with Intel RAID BIOS Console Note: The RMFBU2 properties are view only. Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide 9
17 Using Intel RAID Web Console 2 To view the status of all RMFBU2 connected to RAID modules in the server, select the Physical tab in the left panel of the Intel RAID Web Console 2. To see the RMFBU2, select the controller. The RMFBU2 appears as the last item on the list under that module (see Figure 11). An icon (small green or red icon) appears in the left pane to indicate the RMFBU2 status. The green indicates normal operation and the red indicates the RMFBU2 has failed. Figure 11. RMFBU2 Information in Intel RAID Web Console 2 10 Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
18 4 RAID Maintenance Free Backup Unit Specifications MegaRAID CacheVault TM Technology LSI* MegaRAID CacheVault TM flash cache protection uses NAND flash memory powered by a supercapacitor to protect data stored in the MegaRAID controller cache. This module eliminates the need for a lithium ion battery traditionally used to protect DRAM cache memory on PCI RAID controllers. The RAID controller automatically writes the data in cache to flash when a power failure occurs, while the super-capacitor keeps the current going during the process. When the power comes back, the DRAM is recovered from flash and the system goes on without loss of data. The benefits of this technology are elimination of hardware maintenance associated with LiON batteries, lower total cost of ownership over the life of the adapter, and more environmentally friendly cache protection. Table 2. RMFBU2 Specifications Specifications RMFBU2 SuperCap2 Operating Environment 0 C to 55 C SuperCap2 Storage Temperature 0 C to 70 C Fast Charge Rate SuperCap2 Voltage SuperCap2 Capacity SuperCap2 Mechanical RMFBU2 Mechanical SuperCap2 Charge Time RMFBU2 Shelf Life RMFBU2 Warranty RMFBU2 Cache-offload Module Capacity Smart Monitoring 500 ma Maximum Voltage: 13.2 V Nominal Voltage: 9.5 V 6.4 F (where F is the unit Farad) 65 mm x 52 mm 87 mm x 57 mm Typical: Approximately two minutes Two years Intel provides a three year warranty on the Intel RAID Maintenance Free Backup Unit ARMFBU2. 2 GB NAND Flash Temperature is monitored using the I 2 C interface. Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide 11
19 5 Regulatory and Compliance Information Product Regulatory Compliance Product Safety Compliance The Server Board SE7210TP1-E complies with the following safety requirements: UL60950 CSA (USA/Canada) EN60950 (Europe) IEC60950 (International) CB Certificate and Report, IEC60950 (report to include all country national deviations) GOST R Listed on one System License (Russia) Belarus License Listed on System License (Belarus) CE Low Voltage Directive 73/23/EEE (Europe) IRAM Certification (Argentina) Product EMC Compliance Class A Compliance Note: Legally, the product is required to comply with Class A emission requirements as it is intended for a commercial type market place. Intel targets 10db margin to Class A Limits The Server Board SE7210TP1-E has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed on a compatible Intel host system. For information on compatible host system(s), refer to Intel s Server Builder website or contact your local Intel representative. FCC /ICES-003 Emissions (USA/Canada) Verification CISPR 22 Emissions (International) EN55022 Emissions (Europe) EN55024 Immunity (Europe) CE EMC Directive 89/336/EEC (Europe) AS/NZS 3548 Emissions (Australia/New Zealand) BSMI CNS13438 Emissions (Taiwan) GOST R Emissions Listed on one System License (Russia) GOST R Immunity Listed on one System License (Russia) Belarus License Listed on one System License (Belarus) RRL MIC Notice No (EMC) and (EMI) (Korea) 12 Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
20 Certifications/Registrations/Declarations UL Certification (US/Canada) CE Declaration of Conformity (CENELEC Europe) FCC/ICES-003 Class A Attestation (USA/Canada) C-Tick Declaration of Conformity (Australia) MED Declaration of Conformity (New Zealand) BSMI Certification (Taiwan) GOST Listed on one System License (Russia) Belarus Listed on one System License (Belarus) RRL Certification (Korea) Ecology Declaration (International) Product Regulatory Compliance Markings This product is marked with the following Product Certification Markings: Table 3. Product Certification Markings Regulatory Compliance Country Marking UL Mark USA/Canada CE Mark Europe FCC Marking (Class A) USA EMC Marking (Class A) Canada CANADA ICES-003 CLASS A CANADA NMB-003 CLASSE A BSMI Marking (Class A) Taiwan RRL MIC Mark Korea Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide 13
21 Electromagnetic Compatibility Notices FCC (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Any changes or modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment. The customer is responsible for ensuring compliance of the modified product. Only peripherals (computer input/output devices, terminals, printers, and so on) that comply with FCC Class A or B limits may be attached to this computer product. Operation with noncompliant peripherals is likely to result in interference to radio and TV reception. All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals that are not shielded and grounded may result in interference to radio and TV reception. Industry Canada (ICES-003) Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: Apparelis Numériques, NMB-003 édictee par le Ministre Canadian des Communications. 14 Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
22 This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard entitled: Digital Apparatus, ICES-003 of the Canadian Department of Communications. Europe (CE Declaration of Conformity) This product has been tested in accordance too, and complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance. Taiwan Declaration of Conformity (BSMI) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. Korean Compliance (RRL) English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4. Date of Manufacturer: Refer to date code on product 5. Manufacturer/Nation: Intel Corporation/Refer to country of origin marked on product Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide 15
23 Getting Help World Wide Web Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). Before calling, fill out the Intel Server Issue Report Form. A sample form is provided on the following pages. However, for the fastest service, please submit your form over the Internet. In U.S. and Canada In Europe UK France Germany Italy Spain Belgium In Asia-Pacific region Australia Hong Kong Finland Denmark Norway Sweden Holland Indonesia Malaysia Korea New Zealand China (toll-free) Pakistan (IDD from Philippines) (not toll-free) Philippines Singapore Thailand India (manual Vietnam (IDD from Philippines) toll-free. From India, you need an Myanmar (from Philippines) IDD-equipped telephone) Cambodia (from Philippines) Taiwan In Japan (Domestic) (outside country) 16 Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
24 In Latin America Brazil Mexico Contact AT&T USA at Once connected, dial Colombia Contact AT&T USA at Once connected, dial Costa Rica Contact AT&T USA at Once connected, dial Panama Contact AT&T USA at Once connected, dial Chile (Easter Island) Contact AT&T U SA at Once connected, dial Chile (Mainland and Juan) Contact AT&T USA at Once connected, dial Miami Ecuador (Andimate) Contact AT&T USA at Once connected, dial Ecuador (Pacifictel) Contact AT&T USA at Once connected, dial Guatemala Contact AT&T USA at Once connected, dial Venezuela Contact AT&T USA at Once Argentina connected, dial Contact AT&T USA at Once connected, dial Paraguay Peru Uruguay For an updated support contact list, see Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide 17
25 6 Intel Server Issue Report Form Date Submitted: Company Name: Contact Name: Address: Intel Server Product: Priority (Critical, Hot, High, Low): Brief Problem Description. Provide a brief description below. See the last page for space to include a detailed problem description. Board/Chassis Information Baseboard Revision PBA#: DIMM Configuration Baseboard Serial Number: DIMM1A MB: CPU1 Speed/Stepping/Spec: DIMM1A Vendor/part number: CPU2 Speed/Stepping/Spec: DIMM1B MB: System BIOS Version: DIMM1B Vendor/part number: HSC Firmware Version: DIMM2A MB: Chassis Model DIMM2A Vendor/part number: Intel SC5200 Base DIMM2B MB: Intel SC5200 Base Redundant Power DIMM2B Vendor/part number: Intel SC5250-E Intel SR1350-E Other (Vendor/Model): 18 Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
26 Operating System Information Operating System Version Service Pack Peripheral Information Check each box below that is used, and provide the requested information. Peripheral Card Or Peripheral Description Driver Revision IRQ # I/O Base Address FW Rev# P64 Segment C (PCI- 64/133) PCI Slot 1 PCI Slot 2 P64 Segment B (PCI- 64/100) PCI Slot 3 PCI Slot 4 P32 Segment A (PCI 32/33) PCI Slot 5 PCI Slot 6 Video NIC On-Board Video Add-in Video On-Board NIC1 (10/100 Mb) On-Board NIC2 (1.0 Gb) Hard Drive Information: IDE # of drives installed: Make/Model/Firmware Revision SCSI # of drives installed: Make/Model/Firmware Revision SATA # of drives installed: Make/Model/Firmware Revision Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide 19
27 Complete Problem Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troubleshooting already done. 20 Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide
Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP
Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products
Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S
Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number: E13860-004 Disclaimer Information
Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products
Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number: E12567-002 Disclaimer Information
Intel RAID Maintenance Free Backup Unit AXXRMFBU2 User s Guide
Intel RAID Maintenance Free Backup Unit ARMFBU2 User s Guide A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products Intel Order Number: G49043-005 Disclaimer Information
4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System
4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System Order Number: G23758-002 G23758-002 This document provides instructions for installing the following accessory kit: FUP4X35HSDK
Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, and AXXRPFKSNSH Installation Guide
Intel RAID Premium Feature Key AXXRPFKSSD, AXXRPFKDE, and AXXRPFKSNSH Installation Guide Order Number: E88588-001 E88588-001 IMPORTANT: Your Intel RAID Controller must be programmed with the latest Intel
Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide
Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Thank you for buying an Intel RAID Maintenance Free Backup Unit 4. The Intel RAID Maintenance Free Backup Unit 4 supports the Intel
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide Thank you for buying an Intel RAID Module. Your Intel RAID Module provides reliability,
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide 49760-00, Revision A January 2011 49760-00A Revision History Version and Date 49760-00 Rev. A, January 2011 Initial release of
Gateway Port Replicator User Guide
Gateway Port Replicator User Guide Using the Port Replicator Identifying features Connecting and disconnecting the port replicator 1 Using the Port Replicator Top Power button Component Icon Description
MegaRAID LSIiBBU08 Intelligent Battery Backup Unit. Quick Installation Guide
MegaRAID LSIiBBU08 Intelligent Battery Backup Unit Quick Installation Guide 46307-00, Revision A, August 2010 Revision History Version and Date 46307-00, August 2010 Initial release of document. Description
Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: 022808 PN: 883884-07L Rev. A
Installation Guide Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit Issue: 022808 PN: 883884-07L Rev. A ii Copyright Notice 2008, Wyse Technology Inc. All rights reserved. This manual and the
Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide
Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608 Installation Guide Introduction The NETGEAR 5/8-Port Gigabit Ethernet Switch Model GS605 / GS608 provides you with a high-speed, reliable, easy-to-use
AXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
StorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
Scout 1U Rackmount Computer
Model Numbers ACC-CPU-RM- WIN7x64 ACC-CPU-RM-2008 Revision 5 Scout 1U Rackmount Computer Introduction The Scout 1U Rackmount Computer includes a solid state hard drive loaded with the Microsoft Windows
GSM-EXT Cable Assembly Installation Guide
GSM-EXT Cable Assembly Installation Guide For Documentation and Online Support: http://www.security.honeywell.com/hsc/resources/mywebtech General Information The GSM-EXT cable assembly is used to connect
4 Port PCI Express Gigabit Ethernet PoE PSE Network Card
4 Port PCI Express Gigabit Ethernet PoE PSE Network Card ST4000PEXPSE *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía
HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide
HP SuperSpeed USB 3.0 PCIe x1 Card User Guide Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide
16-port Gigabit Switch 10/100/1000 Mbps GS116 Installation Guide Introduction The NETGEAR 16-port Gigabit Switch Model GS116 provides you with a low-cost, reliable, high-performance switch to connect up
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
Power Supply Guide Version 1.0 for D-Show
Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731
About the HotWire 7900 10-Slot Standalone Shelf
TM HotWire Model 7900 10-Slot Standalone Shelf Installation Instructions Document Number 7900-A2-GN10-10 About the HotWire 7900 10-Slot Standalone Shelf The HotWire 7900 10-Slot Standalone Shelf is designed
Technical Support. Support Information
Technical Support Please refer to the Support Information card that shipped with your product. By registering your product at www.netgear.com/register, we can provide you with faster expert technical support
USB 3.0 to M.2 NGFF SSD Enclosure with UASP
USB 3.0 to M.2 NGFF SSD Enclosure with UASP SM2NGFFMBU33 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
Upgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
MegaRAID SAS 9271-4i and SAS 9271-8i RAID Controllers
MegaRAID SAS 9271-4i and SAS 9271-8i RAID Controllers Quick Installation Guide 53822-00, Rev. A 53822-00A Revision History Version and Date 53822-00, Rev. A, June, 2012. Initial release of the document.
Energy Smart Electric Water Heater Controller
Installation, Operation and Troubleshooting Instructions Energy Smart Electric Water Heater Controller Table of Contents Installation and Setup, 2 Operation, 5 Troubleshooting, 7 Regulatory Notices, 11
Power Over Ethernet Adapters POE101
Power Over Ethernet Adapters POE101 Installation Guide Introduction NETGEAR POE101 Power over Ethernet adapters are designed to supply operational power to devices through an Ethernet cable. These adapters
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE
iosafe Solo External Hard Drive
Users Manual & Limited Warranty iosafe Solo External Hard Drive USB 2.0 Fireproof Waterproof FloSafe Cooling Technology Data Recovery Service 910-10841-00 REV 7.1 2 COPYRIGHTS Copyright iosafe, Inc. 2009.
IDE ATA/133 Controller
IDE ATA/133 Controller 2 Port PCI ATA-133 IDE Adapter Card PCIIDE2 Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class
esata 6G RAID PCIe 2.0 Controller Card
esata 6G RAID PCIe 2.0 Controller Card User Manual Table of Contents Part 1: Introduction Page 3 a. Overview Page 3 b. MAXPower esata 6G RAID Features Page 3 c. What is esata 6Gb/s? Page 3 d. What is RAID?
Intel Entry Server Chassis SC5275-E
Product Brief Intel Server Chassis SC5275-E Support for Dual Intel Xeon Processors Extensive Storage Capacity Power and Thermal Headroom Intel Entry Server Chassis SC5275-E A powerful, reliable, and cost-effective
BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES
NOTES BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability Quick Start Guide This is a Class A device and is not intended for use in a residential environment. Important
FortiFone QuickStart Guide for FON-670i and FON-675i
FortiFone QuickStart Guide for FON-670i and FON-675i FortiFone QuickStart Guide for FON-670i and FON-675i Revision 2 September 25, 2015 Copyright 2015 Fortinet, Inc. All rights reserved. Fortinet, FortiGate,
Intel RAID Controllers
Intel RAID Controllers Best Practices White Paper April, 2008 Enterprise Platforms and Services Division - Marketing Revision History Date Revision Number April, 2008 1.0 Initial release. Modifications
Avaya 1100 Series Expansion Module User Guide. Avaya Business Communications Manager
Avaya 1100 Series Expansion Module User Guide Avaya Business Communications Manager Document Status: Standard Document Number: NN40050-118 Document Version: 02.02 Date: May 2010 2010 Avaya Inc. All Rights
WD VelociRaptor. User Manual. Internal Desktop
WD VelociRaptor User Manual Internal Desktop WD Service and Support Should you encounter any problem, please give us an opportunity to address it before returning this product. Most technical support questions
Intel Server System P4000RP Family Service Guide A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products
Intel Server System P4000RP Family Service Guide A Guide for Technically Qualified Assemblers of Intel identified Subassemblies/Products Order Number: G89704-001 Disclaimer Disclaimer INFORMATION IN THIS
USB Mini Print Server PS121. Installation Guide
USB Mini Print Server PS121 Installation Guide Introduction Thank you for purchasing a NETGEAR PS121 USB Mini Print Server. With this print server you can share your printer with all the computers in your
RocketStor SMART RAID
RocketStor SMART RAID User Guide v1.0 1 Copyright HighPoint Technologies Inc., 1995-2012. All rights reserved. OS X and Macintosh are registered trademarks of Apple Corporation. All other trademarks and
HP SATA/SAS hard drive and Solid State Drive installation
HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal
External Hard Drive esata & USB 2.0 Combo. User Guide English
External Hard Drive esata & USB 2.0 Combo User Guide English Contents Introduction 3 Controls, Connectors and Indicators 3 Front Panel Area 3 Rear Panel Area 3 About the Hard Drive 4 Locating the Drive
Triple Expansion Chassis
Triple Expansion Chassis AP9604 Installation Manual Contents Introduction............................. 1 Installation.............................. 2 Power Considerations...................... 5 Operations..............................
Removable 2.5 SATA HDD Backup System
Removable 2.5 SATA HDD Backup System SAT2510U3REM SAT2510U3S *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
EVGA Z97 Classified Specs and Initial Installation (Part 1)
User Guide EVGA Z97 Classified Specs and Initial Installation (Part 1) - 1 - Table of Contents Before you Begin 3 Parts Not in the kit.4 Intentions of the kit 4 Motherboard Specifications 5 Unpacking and
This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.
Installation Guide This guide explains how to install an (Intel SSD) in a SATA-based desktop or notebook computer. The instructions include migrating your data from your current storage device (such as
ARCHOS (www.archos.com/support).
1 ! www.archos.com/register, ARCHOS.. ARCHOS, (www.archos.com/register).. ARCHOS (www.archos.com/support)., Windows, Windows Help Start ( ), Help and Support.. ARCHOS. 2 ,.! /, : ARCHOS 9,,,,,. -.,. ARCHOS
LaCie 12big Rack Network
LaCie The Ultimate Corporate File-Sharing Solution. Network-Attached and Block Storage up to 96TB Customizable. Robust. Enterprise Class. Network-Attached Storage Just Got 12 Times Better. A Complete Network
Intel SC5100 Pedestal and Rack Server Chassis Subassembly Product Guide
Intel SC5100 Pedestal and Rack Server Chassis Subassembly Product Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number: A55454-003 http://support.intel.com/support/motherboards/server/chassis/sc5100
PCI Express 10GBase-LR/SR/LRM Fiber Network Card with Open SFP Slot
PCI Express 10GBase-LR/SR/LRM Fiber Network Card with Open SFP Slot PEX10000SFP *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com
PCI USB 2.0 Card PCI225USB PCI225USB_LP PCI425USB PCI625USB2I. Instruction Manual. Actual product may vary from photo
PCI USB 2.0 Card 2 Port High-Speed USB 2.0 PCI Card 2 Port High-Speed USB 2.0 Low-Profile PCI Card 4 Port High-Speed USB 2.0 PCI Card 6 Port High-Speed USB 2.0 PCI Card PCI225USB PCI225USB_LP PCI425USB
Intel RAID Expander Card RES3TV360 Hardware User's Guide. Intel Order Number: H40805-002
Intel RAID Expander Card RES3TV360 Hardware User's Guide Intel Order Number: H40805-002 DISCLAIMER IINFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
4 Port PCIe 2.0 SATA III 6Gbps RAID Controller
4 Port PCIe 2.0 SATA III 6Gbps RAID Controller PEXSAT34SFF *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
EPSON USB/Parallel Adapter User s Guide
EPSON USB/Parallel Adapter User s Guide EPSON Stylus COLOR 440 EPSON Stylus COLOR 800 EPSON Stylus COLOR 600 EPSON Stylus COLOR 850 EPSON Stylus COLOR 640 EPSON Stylus COLOR 1520 EPSON Stylus Photo EX
SATA PCI Express Adapter PEXSATA22I
SATA PCI Express Adapter PEXSATA22I FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These
Intel RAID Controller Troubleshooting Guide
Intel RAID Controller Troubleshooting Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Intel order number C18781-001 September 2, 2002 Revision History Troubleshooting
2 Bay USB 3.0 RAID 3.5in HDD Enclosure
2 Bay USB 3.0 RAID 3.5in HDD Enclosure SAT3520U3SR *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com
Inspiron 15. Service Manual. 3000 Series
Inspiron 15 3000 Series Service Manual Computer Model: Inspiron 15 3541/Inspiron 15 3542/Inspiron 15 3543 Regulatory Model: P40F Regulatory Type: P40F001/P40F002 Notes, Cautions, and Warnings NOTE: A NOTE
Broadband Telecommunications Drop Amplifier
INSTALL SHEET BDA Broadband Telecommunications Drop Amplifier Introduction The Broadband Telecommunications Drop Amplifier (BDA) is a two-way, 1 GHz amplifier designed for customer-premise amplification
Rocket 640L/644L 6Gb/s SATA Host Adapter Quick Installation Guide
Rocket 640L/644L 6Gb/s SATA Host Adapter Quick Installation Guide v1.1 1 Contents HighPoint Rocket640L/644L...3 Hardware Installation...3 Using the Rocket64xL Adapter...4 Rocket 64xL BIOS...4 Driver and
2013 VTech Printed in China 91-009656-000 US
Rechargeable Power Pack User s Manual 2013 VTech Printed in China 91-009656-000 US INTRODUCTION The Rechargeable Power Pack makes it easier than ever to keep the InnoTab 3 or InnoTab 3S charged and ready
ES-3305P V2 / ES-3308P V2. Quick Installation Guide. 09-2013 / v1.0
ES-3305P V2 / ES-3308P V2 Quick Installation Guide 09-2013 / v1.0 1 COPYRIGHT Copyright Edimax Technology Co., Ltd. all rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
SSDNow For Desktops. Installation Guide
Installation Guide Your purchase of the SSDNow with Accessory Kit will allow you to enjoy the benefits of increased system performance and reliability. All hardware and software necessary to replace your
2-Disk RAID USB and esata External Hard Drive. User Guide English
2-Disk RAID USB and esata External Hard Drive User Guide English 1 Contents Introduction 3 Drive Contents: IMPORTANT Notice 3 Nero BACKITUP 2 Software 3 Controls, Connectors and Indicators 4 Front Panel
PCI Express USB 3.0 Controller Adapter Card
PEXUSB3S2 Instruction Manual PCI Express USB 3.0 Controller Adapter Card 2-Port PCI Express SuperSpeed USB 3.0 Controller Adapter Card FCC Compliance Statement This equipment has been tested and found
ATA User Manual. iinet ATA Telephone Adapter. Setting up for ADSL and VoIP. For model F1PG200ENau
ATA User Manual Please insert your installation CD now and then follow the on screen instructions iinet ATA Telephone Adapter Setting up for ADSL and VoIP. For model F1PG200ENau F1PG200ENau Table of Contents
Installation Guide. APA-1460 SlimSCSI. PCMCIA-to-SCSI Host Adapter
R Installation Guide APA-1460 SlimSCSI PCMCIA-to-SCSI Host Adapter Introduction This document explains how to install and use Adaptec s APA -1460 SlimSCSI PCMCIA-to-SCSI adapters. The SlimSCSI adapters
Release Notes: PowerChute plus for Windows 95 and Windows 98
: PowerChute plus for Windows 95 and Windows 98 These release notes supplement the User s Guide: PowerChute plus, Version 5.0.2, for Windows 95 and Windows 98 (pc98ug.pdf) and the Installation Guide: PowerChute
Intel NUC Kit DC3217IYE User Guide. Intel NUC Kit DC3217IYE
Intel NUC Kit DC3217IYE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety practices
PCI Express USB 2.0 Adapter Card
PEXUSB400 Instruction Manual PCI Express USB 2.0 Adapter Card 4-Port (Independent) PCI Express to High Speed USB 2.0 Adapter Card FCC Compliance Statement This equipment has been tested and found to comply
USB to IDE or SATA Adapter
USB to IDE or SATA Adapter USB 2.0 to IDE or SATA Adapter Cable USB2SATAIDE Instruction Manual Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply
Wall-Mounting your HP computer. User Guide
Wall-Mounting your HP computer User Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should
FortiFone QuickStart Guide for FON-370i
FortiFone QuickStart Guide for FON-370i FortiFone QuickStart Guide for FON-370i Revision 2 August 17, 2015 Copyright 2015 Fortinet, Inc. All rights reserved. Fortinet, FortiGate, FortiCare and FortiGuard,
Conference Phone UserÕs Manual. Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc.
Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc. UserÕs Manual Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of
Instruction Guide. 2/4/6-port PCI USB 2.0 card PCI225USB PCI425USB PCI625USB2I. The Professionals Source For Hard-to-Find Computer Parts
USB 2.0 CARD 2/4/6-port PCI USB 2.0 card PCI225USB PCI425USB PCI625USB2I Instruction Guide *PCI225USB shown * Actual product may vary from photo The Professionals Source For Hard-to-Find Computer Parts
Replacing the Gateway M675 Keyboard
Replacing the Gateway M675 Keyboard This package includes a replacement keyboard for your Gateway M675 notebook and these printed instructions. Tools you need You need a small Phillips screwdriver and
IN24 IN26. User s Guide
IN4 IN6 User s Guide Please read the safety instructions booklet before setting up the projector. Unpack the box Here s what s included: Projector Remote CD-ROM Product Registration and Reference Guide
Wireless Internet Keyboard and Laser Mouse
Wireless Internet Keyboard and Laser Mouse User s Manual Model KB1045LSR FCC STATEMENT KB1045LSR This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: (1)
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
HLWLAN 802.11b/g/n Transceiver Kit
092524 RevB HLWLAN 802.11b/g/n Transceiver Kit Wireless Communications for OmniLogic Owner s Manual Contents Introduction...1 Installation...2 Configuration...6 Operation...8 Troubleshooting...9 HLWLAN
How To Use A Fortivoice Phone On A Cell Phone On An Ipad Or Ipad (For A Sim Sim) On A Simplon (For An Ipod) On An Iphone Or Ipod (For Ipad)
FortiFone QuickStart Guide for FON-260i FortiFone QuickStart Guide for FON-260i Revision 3 27-400-195511-20130729 Copyright 2013 Fortinet, Inc. All rights reserved. Fortinet, FortiGate, and FortiGuard,
Inspiron 13. Service Manual. 7000 Series. Computer Model: Inspiron 13 7348 Regulatory Model: P57G Regulatory Type: P57G001
Inspiron 13 7000 Series Service Manual Computer Model: Inspiron 13 7348 Regulatory Model: P57G Regulatory Type: P57G001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps
TL-PS310U Single USB 2.0 Port MFP and Storage Server
TL-PS310U Single USB 2.0 Port MFP and Storage Server Rev: 2.0.0 1910010313 Contents Chapter 1 Introduction... 1 1.1 Product Overview...1 1.2 Network Management...1 1.3 Components and Features...1 1.4 Hardware
2x M.2 NGFF SSD RAID Controller Card plus 2x SATA Ports
2x M.2 NGFF SSD RAID Controller Card plus 2x SATA Ports PEXM2SAT3422 *actual product may vary from photos FR: Guide de l utilisateur - fr.startech.com DE: Bedienungsanleitung - de.startech.com ES: Guía
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Intel Remote Management Module User s Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products
Intel Remote Management Module User s Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number D48601-001 Disclaimer Information in this document
CompactRIO crio-9052
OPERATING INSTRUCTIONS CompactRIO crio-9052 CompactRIO StarFabric Interface 1 POWER BACKUP STATUS FPGA V1 C V2 2 C Rx INPUT 9 35 V 17 W MAX 3 Tx NI crio-9052 CompactRIO StarFabric Interface 1 LEDs 2 Power
5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105
5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105 Installation Guide Introduction The NETGEAR 5-Port Gigabit Ethernet Switch Model GS105 provides you with a low-cost, reliable, high-performance switch
P73474-F5U006-UNV-AM-man.qxd 9/18/00 10:10 AM Page 1
P73474-F5U006-UNV-AM-man.qxd 9/18/00 10:10 AM Page 1 En 4-Port USB PCI Card User Manual Guide d utilisation de la carte PCI USB à quatre ports Manual de usuario para la tarjeta PCI USB de 4 puertos Placa
Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10
Business Audio System: Music & Messaging MP3 Player by Grace Digital Audio User Guide Model No. GDI-USBM10 User Guide Contents Introduction 2 Safety & General Use Information 2 Features 3 Set Up & Operation
4 Port PCI Express Low Profile High Speed USB Card
4 Port PCI Express Low Profile High Speed USB Card PEXUSB4DP DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com IT: Guida per
TG-3468 Gigabit PCI Express Network Adapter
TG-3468 Rev:2.0.0 1910010580 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks
AastraLink RP 500. Installation Guide. 41-001244-00 Rev 03
AastraLink RP 500 Installation Guide 41-001244-00 Rev 03 Software License Agreement Aastra Telecom Inc., hereinafter known as "Seller", grants to Customer a personal, worldwide, non-transferable, non-sublicenseable
Aura SSD. for the 2013 Apple Mac Pro INSTALLATION GUIDE
Aura SSD for the 2013 Apple Mac Pro INSTALLATION GUIDE TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 SYSTEM REQUIREMENTS 1.2 PACKAGE CONTENTS 1.3 ABOUT THIS MANUAL 2. INSTALLATION...2 2.1 PREPARING THE MAC
DataCenter 7280 3Gb/s SATA Host Adapter User Manual
DataCenter 7280 3Gb/s SATA Host Adapter User Manual Revision: 1.1 Date: May 2011 HighPoint Technologies, Inc. Copyright... 3 Trademarks... 3 HighPoint Technologies, Inc.... 4 Highpoint DataCenter 7280
Dual msata SSD to 2.5in SATA SSD Converter with RAID
Dual msata SSD to 2.5in SATA SSD Converter with RAID 25SAT22MSAT *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del