Air Conditioning in Green Office Buildings?



Similar documents
Energy Efficient HVAC-system and Building Design

HVAC Systems: Overview

ENERGY SAVINGS BY CHANGING CONSTANT AIR VOLUME SYSTEMS (CAV) TO VARIABLE AIR VOLUME SYSTEMS (VAV) IN EXISTING OFFICE BUILDINGS.

HVAC Processes. Lecture 7

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

ENHANCED LABORATORY HVAC SYSTEM

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

Comparison between Decentralised and Centralised Air Conditioning Systems

Under sill units. Type FSL-B-ZAS

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Fläkt Woods Building Future

Mechanical and Natural Ventilation

Basics of HVAC Cleaning

Analysis of HVAC Control Strategies

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Lesson 36 Selection Of Air Conditioning Systems

CAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND?

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

for K-12 School Buildings

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone.

Mistrale. Fusion Terminal

HVAC Systems in Schools & Commercial Buildings and Radon

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Leveraging the Power of Intelligent Motor Control to Maximize HVAC System Efficiency

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas


Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Federation of European Heating, Ventilation and Air-conditioning Associations

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

The compact unit series

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Dehumidification Design

UNDERFLOOR AIR DISTRIBUTION

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

Mechanical Systems Proposal revised

Direct Fresh Air Free Cooling of Data Centres

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

APPLICATION GUIDE. Moisture Management in Waterborne Climate Systems

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

Norwegian Tax Authority - Oslo Norway

UNDER FLOOR AIR CONDITIONING SAVE MONEY AND TRANSFORM YOUR WORK SPACE

Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice

AIR DISTRIBUTION FOR COMFORT AND IAQ

DEVELOPMENT OF AN OPEN SOURCE HOURLY BUILDING ENERGY MODELING SOFTWARE TOOL

How To Get A Passive House

AIR CONDITIONING - ENERGY CONSUMPTION AND ENVIRONMENTAL QUALITY

ASTACEA4 Inspect complex/central air conditioning systems

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Design Options for HVAC Distribution Systems

Combi Unit Genius. The energy efficient Building Service Centre

University of St Andrews. Energy Efficient Data Centre Cooling

Climotion ensures a better climate. Better comfort and lower costs in all buildings. Bosch Energy and Building Solutions

How To Design A Building In New Delhi

OPTIMIZATION OF VENTILATION SYSTEMS IN OFFICE ENVIRONMENT, PART II: RESULTS AND DISCUSSIONS

3/29/2012 INTRODUCTION HVAC BASICS

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Design Options For HVAC Distribution System

FULL DC INVERTER SYSTEMS

Active & Passive Beams

Glossary of Heating, Ventilation and Air Conditioning Terms

How To Control Humidity With A Humidifier

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

Example of audit of an air conditioning system

Kan behovsstyrt ventilasjon erstatte lokal varme? Axel Cablé, SINTEF Seminar

Analysis of data centre cooling energy efficiency

Building Energy Systems. - HVAC: Heating, Distribution -

Displacement ventilation

Air-water systems for efficient air conditioning

HRV and ERV Best Practices. December 18, 2012 Portland Metro Home Builders Association

The Business Case Annual fuel cost savings of 26% worth more than 28,000 Annual fuel savings of 1.3million kwh Annual CO2 savings of over 245 tonnes

DUCTED AIR CONDITIONING SOLUTIONS

Ventilation for buildings Energy performance of buildings Guidelines for inspection of air-conditioning systems

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

UNDER FLOOR AIR DISTRIBUTION (UFAD) SOLUTIONS

All the best brands all under one roof

Radiant Heating and Cooling Systems BY KWANG WOO KIM, ARCH.D., MEMBER ASHRAE; BJARNE W. OLESEN, PH.D., FELLOW ASHRAE

Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program

EnergyPro Building Energy Analysis. Assisted Living Building

Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat

RRV934. Multi-controller. Synco living

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Federation of European Heating, Ventilation and Air-conditioning Associations

Guidelines for inspection of air-conditioning systems Prof. Dr. Ing. Iolanda Colda UTCB

Transcription:

Air Conditioning in Green Office Buildings? How to implement Demand Controlled Ventilation Stuttgart Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 1

Air Conditioning in Green Office Buildings ventilation heating / cooling energy pass certification DIN EN 15251 Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 2

Greenbuild Objectives compact building shape (A/V) well balanced window area (SHGC tot f Window < S max ) building mass as thermal storage low indoor loads - low pollution loads (low-olf- building) - low heating loads (< 20 W/m²) - low cooling loads (< 45 W/m²) Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 3

why Air Conditioning? high indoor air quality by mechanical ventilation - demand controlled, efficient ventilation - low draught risk (DR<15%) - low vertical temperature gradient limited room air humidity - minimal humidity in heating mode (mech. humidification) - maximal humidity in cooling mode (mech. cooling and dehumidification) limited room temperature in cooling mode - combined with decentralised secondary cooling system constraints - primary energy demand < reverence demand by EnEV 2009 - maximal rating by certification of LEED, BREAM,... Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 4

higly efficient Air Diffuser (1) low ventilation rate per diffuser, high ventilation efficiency high difference supply - room temperature (+5 to -10 K) low velocities close to the diffuser linear floor diffuser LDU air flow pattern in LTG testroom Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 5

higly efficient Air Diffuser (2) high ventilation rate per diffuser, high ventilation efficiency high difference supply - room temperature (+5 to -12 K) combination with induction unit linear slot diffuser LDB for ceilings air flow pattern in LTG testroom Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 6

Focus on Energy Efficiency heat recovery - heat recovery coefficient > 0,75 Air Handling Energy Costs per m³/h heating energy 0,06 / electr. current 0,14 / cooling energy 0,05 /kwh humidification - gliding relative humidity (>30% r.h.) - moisture recovery (>40% r.h.) cooling, dehumidification - 16-18 C supply air temperature - gliding moisture (< 12gw/kga) ventilation - low SFP- values energy costs [ / a / (m³/h) ] 0,60 0,50 0,40 0,30 0,20 0,10 0,00 ventilation; SFP = 3,2 kw / (m³/s) ventilation heat; 18 C; with / without heat recovery humidification <30%; with / without moisture transmission with without cooling; 16-18 C; with / without dehumidification - smaller air volume rates - shorter AHU running times Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 7

Certification of Indoor Air Quality Ventilation Rate [m³/h/m²] 30 25 20 15 10 5 0 Recommended Outdoor-Ventilation Rates dependent on category, low polluting (DIN EN 15251) category 1 category 2 category 3 0 5 10 15 20 Floor Area per Person [m²/p] V A out = qp A / n + q B A floor area q P ventilation rate per person q B ventilation rate for emissions from building Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 8

Design of AHU for CAV mean density of occupancy 15m²/person example (CAV-system) - low polluting building - category II 4,2 m³/h/m² (design start, SFP= 3,2 kw/(m³/s)) - category I 6,0 m³/h/m² (target value: high IAQ) - 43% higher ventilation rate - solution 1 design AHU up to 5 m³/h/m² increase ventilation rate to 6m³/h/m² by frequency inverter - solution 2 design AHU up to 6m³/h/m² same SFP & velocities Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 9

Energy Costs dependent on V/m² costs [ /m²/a ] 8 7 6 5 4 3 2 1 0 AHU Energy Costs CAV-System with 3.250 h of operating p. a. 2 3 4 5 6 7 8 ventilation rate [ m³/h/m² ] electr. current (vel. var.) electr. current (vel. const.) heating design start solution 2 solution 1 Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 10

First Costs dependent on V/m² costs [ /m 100 90 80 70 60 50 40 30 20 10 0 First Costs CAV-System 2 3 4 5 6 7 8 ventilation rate [ m³/h/m² ] AHU ducts construction costs (AHU room, shafts) increased height betw een floors Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 11

Results of CAV-System solution 1 annuity 0,1 costs of use [ /m²/a] 4,2 m³/h/m² 6 m³/h/m² difference capital costs of AHU, ducts 3,46 3,87 0,41 capital costs of building constr. 1,02 1,26 0,24 energy costs of electricity 1,90 3,78 1,88 sum 6,38 8,91 2,53 solution 2 annuity 0,1 costs of use [ /m²/a] 4,2 m³/h/m² 6 m³/h/m² difference capital costs of AHU, dutcs 3,46 4,16 0,70 capital costs of building constr. 1,02 2,18 1,16 energy costs of electricity 1,90 2,71 0,81 sum 6,38 9,05 2,67 conclusions - higher ventilation rates of CAV-systems are always linked to higher costs for energy and capital investment - are VAV-systems a better solution? Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 12

Example of a demand controlled Ventilation time 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 hour time schedule 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 AHU operation sensor of occupancy 0 0 0 0 0 0 0 0 1 1 1 1 0 1 1 1 1 0 0 0 0 0 0 0 0 decentral on / off window switch 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 decentral on / off increased mech. ventilation 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 manual switch ventilation rate [m³/h/m²] 10 8 6 4 2 0 V entilation Rates of CAV - & V AV -System s exam ple of a 2-3 persons office 0 2 4 6 8 10 12 14 16 18 20 22 24 time CAV VAV Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 13

Design of AHU for VAV-Operation cat.2 / low emission / c4 1 Person Off. 2-3 Pers.Off. Open Plan Off. Conference mean dim remarks relative frequency 9% 44% 36% 11% 100% occupancy 12 10 15 4 10,25 m²/person operation ratio F_rlt 0,7 0,7 1 0,5 draft DIN V 18599-7 u. T10, Tab. 4 absence coeff. c_rlt 0 0 0 0 draft DIN V 18599-7 u. T10, Tab. 5 design vent.rate - building 2,52 2,52 2,52 2,52 design vent.rate - build.+pers. 4,62 5,04 4,20 8,82 5,12 m³/h/m² CAV mean vent.rate V_dc 3,99 4,28 4,20 5,67 4,38 m³/h/m² with occupancy sensor operation ratio F_nat.vent. 0,7 0,7 1 0,8 natural ventilation, mech. ventilation shut off mean vent.rate V_dc 2,8 3,0 4,2 4,5 3,58 m³/h/m² with occupancy sensor & natural ventilation Comparison of CAV- & VAV-Operation VAV with occupancy sensor centralised AHU potential of electr.energy saving 30% mean ventilation rate demand on electr. energy 20 15 10 5 0 5,12 15,0 CAV 4,38 12,9 VAV with occupancy sensor 3,58 m³/h/m² 10,5 VAV with occupancy sensor & window switch kwh/m²/a 4,38 2,5 VAV by decentralized ahu & occupancy sensor & window switch AHU, ducts 15% smaller higher first costs for VAV decentralised AHU (1/room) potential of electr.energy saving 80% higher first costs for AHU ( /m³/h) higher costs for maintenance ( /m²) no ducts, no ventilation shafts, no ahu rooms Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 14

Example of a Ventilation Control System 4m/s in ducts control ratio 1:3 to 1:4 1 to 4m/s duct velocity in volume flow controler Extract Supply compact controller for supply and tracked exhaust volume flow Type VRD-W flow control principle with control ratio 1 )* - 10m/s and characteristic control field )* supported only by few manufaturers Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 15

Cost-Effectiveness of VAV-Systems savings - ventilation system & construction costs - 6 5m³/h/m² - energy costs for electricity (by VAV) extra first costs for VAV- installation - reference parameters zone of occupancy 30m² ventilated area 400m² - assumptions room automation for lighting, ventilation, heating & cooling using occupancy sensor for lighting & ventilation LON-bus - additional charge for VAV-controller compared with mech. CAV-controller - pressure & volume flow controller in main supply & extract duct 13 occupancy units - window switches 4 per room costs [ /m²/a] 2 1,5 1 0,5 0-0,5-1 -1,5 Balance Sheet VAV-CAV 0,19 0,23 1,09-0,65-0,45 costs for control units in main ducts wiring occupancy sensor costs for window switches additional charge for VAVcontroller (LON) savings by electricity savings by ventilation system Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 16

Example of a decentralised Ventilation Unit exhaustmodule exhaust ventilation damper exhaust fan extract air filter heat- & moisture recovery module heat-, moisture recovery secondary air fan supply- & secondary air mudule heat exchanger heating / cooling supply fan outdoor air filter decentralised ventilation unit FVM outdoor ventilation damper Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 17

Key-Components for green Air Conditioning diffuser - highly inductive close to diffuser (high t) - low velocity, displacement flow in occupance zone induction unit - high secondary capacity at low ventilation rate and low primary pressure - moderate supply water temperature 16 C for cooling, 30 C for heating fancoil with supply diffuser - highly efficient, low noise fan - minimised fan operation time decentralised ventilation unit - SFP < 1,5 kw/(m³/s) - VAV volume controller - high control accuracy at low velocities (1-6 m/s) supply extract ww cw wall diffuser unit LDK floor induction unit HFB fancoil floor unit VKB dec. ventilation unit FVDplus - low pressure drop when damper is open volume control unit VRF-W Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 18

Summary green air conditioning provides for high IAQ all year - at high thermal comfort - and low energy demand primary energy for ventilation, heating, cooling 75-100 kwh/m²/a green air conditioning postulates - a highly efficient use of electricity - highly efficient components - in some respect a responsible attitude of the occupant VAV-systems are, just at low ventilation rates, a sustainable solution - they are more flexible than CAV - the demand of space is smaller - they are easily shut off during natural ventilation - they are better accepted by occupant - savings balance the additional charge for VAV Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 19

Grenzstrasse 7 D - 70435 Stuttgart Tel: +49 (711) 8201-180 Fax: +49 (711) 8201-720 E-Mail: raumluft@ltg-ag.de E-Mail: prozessluft@ltg-ag.de E-Mail: ingenieurdienstleistungen@ltg-ag.de Internet: www.ltg-ag.de Rechte allein bei ICEBO 08 10.10.2008 CI / DrRo 20