Dehumidification Design

Similar documents
HVAC Systems: Overview

HVAC Processes. Lecture 7

Engineers Newsletter. Understanding Single-Zone VAV Systems. providing insights for today s hvac system designer. volume 42 2

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Element D Services Heating, Ventilating, and Air Conditioning

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida

Variable Air Volume - VAV

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings


REAL OPERATING COST SAVINGS FROM RETRO- COMMISSIONING OPPORTUNITIES FOR SAVINGS IN ACADEMIC MEDICAL CENTERS

Flexibility, Efficiency In San Antonio Arena

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Defining Quality. Building Comfort. Precision. Air Conditioning

MULTIZONE APPLICATION OF SOLUTION UNITS

Design Options for HVAC Distribution Systems

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Design Options For HVAC Distribution System

Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project

The Data Center Dilemma - A Case Study

Fundamentals of HVAC Control Systems

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

Glossary of Heating, Ventilation and Air Conditioning Terms

Building Energy Systems. - HVAC: Heating, Distribution -

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

ENHANCED LABORATORY HVAC SYSTEM

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Innovent LASER Packaged Fresh Air Conditioning Units

Preliminary Final Proposal

Why Do I Need Precision Air Conditioning?

National Grid Your Partner in Energy Solutions

Bring the fresh in. Dedicated Outside Air Systems

Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

By Tom Brooke PE, CEM

Lesson 36 Selection Of Air Conditioning Systems

Lower Energy Costs with Rooftop Air-Conditioning Package Units

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Topics for Today. Order of Magnitude Mechanical Estimating. Order of Magnitude Estimate Goal. Project Delivery Methods. Questions for Client

Glossary of HVAC Terms

newsletter engineers energy-saving strategies for Water-Source Heat Pump Systems volume 36 2 providing insights for today s hvac system designer

Mechanical Systems Proposal revised

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

Enclosed Football Stadium Design History and Lessons Learned

HVAC Checklist - Long Form

SAM HOUSTON STATE UNIVERSITY

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

University of St Andrews. Energy Efficient Data Centre Cooling

Raised Floor Data Centers Prepared for the Future

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

HVAC Basic Science - System Capacity

Air Conditioning Clinic

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

Proper Applications & Sequences for Constant Volume Pressure Dependent Zoning Systems. History

for Plans Examiners and Building Inspectors

How To Design A Building In New Delhi

NetApp Data Center Design

HVAC SYSTEMS ACOUSTICAL, COST & ENERGY STUDY

newsletter Let s take a high-level look at airside economizing: what it is, what it requires, and how it s done. How does economizer cooling work?

3/29/2012 INTRODUCTION HVAC BASICS

COMPARATIVE LIFE-CYCLE ANALYSIS OF ENERGY-EFFICIENCY MEASURES AT TVA S CHATTANOOGA OFFICE COMPLEX: PHASE II RESULTS & FINAL DESIGN

Heating, Ventilation & Air Conditioning Equipment

Element D Services Heating, Ventilating, and Air Conditioning

Pool Dehumidification Basics

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone.

Commissioning - Construction Documents (Page 1 of 6)

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Data Center Heat Rejection

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Using Time-of-Day Scheduling To Save Energy

Legacy Data Centres Upgrading the cooling capabilities What are the options?

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

Data Center Energy Profiler Questions Checklist

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

Datacenter Efficiency Program

APPLICATION GUIDE. Moisture Management in Waterborne Climate Systems

How to Build a Data Centre Cooling Budget. Ian Cathcart

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

Introduction to Building Automation Systems (BAS)

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Alan Matzka, P.E., Senior Mechanical Engineer Bradford Consulting Engineers

5.6 Technical Specification: Premium Efficiency Electric Air Conditioning Equipment

Comparing Energy Savings of Different VAV Systems

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

Benefits of. Air Flow Management. Data Center

Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc.

Transcription:

Dehumidification Design Using Data-Center Heat Utilizing free heat from a server room was the concept behind an air-handling system in a college-campus building Considerable energy savings are possible with an innovative approach to HVAC dehumidification design using the typical network/server room or data center in a campus building as a source of free heat. Just a few racks in the network room of a campus building, such as those in the Bush Science Center at Rollins College in Winter Park, Fla., represent enough heat to provide considerable dehumidification. A secondary benefit is that more airflow and cooling is available for a data room than typically is provided, a bonus that delights even the By MIKE WEST, PHD, PE, Advantek Consulting Inc., Melbourne, Fla., and KANNAN RENGARAJAN, PE, Cape Design Engineering Co., Cape Canaveral, Fla. most skeptical information-technology manager. What s more, this dehumidification strategy may help earn credits in the Optimize Energy Performance, Thermal Comfort, and/or Innovation in Design categories of the U.S. Green Building Council s Leadership in Energy and Environmental Design (LEED) for New Construction (LEED-NC) and LEED for Existing Buildings (LEED-EB) Green Building Rating Systems. Conceptual The strategy for achieving dehumidification, energy savings, and LEED credits using this design concept is straightforward: Capture datacenter equipment heat and utilize it for reheat. However, success depends on practical execution. The heat produced by data-processing equipment is fairly constant and predictable year-round. The heat from just one computer-server rack can be anywhere from 4 to more than 12 kw (12 to 40 mbh). Some experts estimate that the rise of high-density environments and designs for future equipment will result in an output of 30 to 50 kw per rack (100 to 170 mbh). Reheat of just a few degrees may be all that is required for good humidity control in a mixed- The five-level Bush Science Center at Rollins College houses a state-of-the-art multimedia classroom auditorium, a data center, and teaching laboratories. The 30-year-old building presents several HVAC design challenges. A member of HPAC Engineering s Editorial Advisory Board, Mike West, PhD, PE, has 12 years of experience as a principal with Advantek Consulting Inc. Kannan Rengarajan, PE, has more than 25 years of design experience, including 10 years as a principal and founding senior mechanical engineer with Cape Design Engineering Co. 34 March 2008 HPAC Engineering

air application. Every 10 kw of server heat (about one rack) is sufficient to raise the temperature of more than 5,000 cfm of airflow by 6 F, from a leaving- condition of 54 F/53 F dry bulb/wet bulb to 60 F/55.5 F dry bulb/wet bulb. In terms of dehumidification capability, this 10 kw of server heat per 5,000 cfm will lower the sensible-heat ratio (SHR) by about 10 percent, depending on space-air and entering-air conditions. With room air at 76 F/55-percent relative humidity, SHR is reduced from 0.69 to 0.62 with 6 F of reheat. As data-center equipment is upgraded, the kilowatt density likely will increase, making this strategy ever more effective. Applications with higher occupant densities and outside-air fractions could require closer to 10 F of reheat. Each typical 10-kw server rack will provide enough reheat for 3,200 cfm of air and lower SHR by 20 percent. With room air of 76 F/55-percent relative humidity, SHR is reduced from 0.69 to 0.55 with 10 F of reheat. For the most demanding dehumidification loads with humid outside air, every 10 kw of rejected server-rack heat will provide almost 15 F of reheat per 2,000 cfm. A nearly neutral -air condition of 70 F/59.3 F dry bulb/wet bulb is provided from the 54 F/53 F dry bulb/ wet bulb leaving- condition. With room air at 76 F/55-percent relative humidity, SHR is reduced by 45 percent, from 0.69 to 0.38, with 15 F of reheat. Therefore, a project s server room or data center preferably located near an occupied space or air handler serving the space that needs added dehumidification might be a good application for this concept. If the size of the conditioned space is approximately 2,500 to 6,500 sq ft per 10-kw server rack, take a closer look at how the air handler and ductwork could be configured. Implementation Capturing and utilizing free heat, Return 74 F Outside air 84 F Return fan Chilled-water A basic example configuration for utilizing data-center heat presents two design hurdles. First, the airflow requirement of an auditorium likely would be far in excess of what is reasonable for a data-server area. Second, West FIGURE there 1. are fire-suppression-system concerns (Size: 27 or 41 picas.) when all of an auditorium s air must first flow through a data-server area. The configuration at Rollins College solved both problems. Reheat (degrees Fahrenheit) 6 10 15 Cubic feet per minute 5,267 3,160 1,975 Supply-air temperature, Fahrenheit 60 64 70 rather than rejecting it to the outdoors, was the design basis for the air-handling 54 F Data-server area Supply-air wet-bulb temperature, Fahrenheit 55.5 57.0 59.3 Supply-air relative humidity, percent 76 66 53 Variable air volume Supply fan Dehumidification capability per 10-kw server rack at 76 F/55-percent relative humidity room air and 54 F/53 F dry-bulb/wet-bulb West leaving TABLE 1.. (Size: 27 picas.) Return air from auditorium Return air from data offices and outside air /filter variable-frequency drive Heating Cooling Two-deck multizone module 64 F Sensible-heat ratio 0.62 0.55 0.3 To auditorium To data room and data offices Basic schematic of AHU-3, which serves the auditorium on the first floor and the data center in the basement of the Bush Science Center. The air handler is located in a mechanical space adjacent to the data center. West FIGURE 2(Size: 27 or 41 picas.) system at the Bush Science Center. The building houses a high-tech classroom HPAC Engineering March 2008 35

Data outside air Filter angled mixing variable-frequency drive turning vanes Face and bypass Heating (small, ½-in. tube, two-row) Cooling (medium/large with access, ½-in. tube, six-row) West FIGURE 3. (Size: 27 or 41 picas.) Data Air-handler modules arranged in a single-fan hot-deck/cold-deck configuration for applications in which static-pressure relationships allow the use of one blower to achieve design airflows. A heating is provided for backup in case server-room heat is unavailable or insufficient. auditorium complete with dual rearprojection screens and several wallhung liquid-crystal-display monitors. One floor below is a data center that has six server racks with a total power rating of 50.2 kw and future plans for five additional racks. The data center originally was cooled with a 15-ton direct-expansion (DX) system that now is used for backup. Problems in the building included excess humidity in the auditorium and an ever-increasing heat load in the data-server room. Rollins College s facilities director, Scott Bitikofer, asked for a simple energy-efficient solution that would handle cooling and dehumidification loads. The new air-handler modules are in a traditional single-fan hot-deck/cold-deck configuration. Mixed air from the data center flows through the hot deck and mixes with chilled-water leaving air as needed to achieve comfort Variable air volume (VAV) outside air (OA) for an occupancy of 101 people Floor 74 F 1,895 cfm 54 F 850 cfm cfm Face and bypass damper and bypass damper 1,040 cfm drive (VFD) fan 85 F (percent of full fan speed) 8,400 cfm 84 F Damper OA cfm area air 90 F mixing box Ceiling plenum 4,885 cfm 1,704 cfm of OA 87 F 74 F A dynamic model was developed to calculate airflows and temperatures at the full range of entering-air temperatures and damper positions for the Bush Science Center project. Typical occupied operating conditions are noted. 36 March 2008 HPAC Engineering West FIGURE 5.

Airflow in AHU-3, a modular air-handling unit, moves from right to left. The chilled-water module is directly beneath the hot-water module in a blow-thru hot-deck/colddeck arrangement. The mixing-damper modules are on the left. conditions. The auditorium is served by a 10,500-cfm modular air-handling unit (AHU) with a variable frequency drive (VFD). The system is supplied with chilled water from a campus central plant. If static-pressure relationships had not allowed use of a single fan, a dual-fan configuration would have been used. The dual-fan configuration could have provided more dehumidification capability and airflow flexibility, but the two fans, associated VFDs, and controls would have increased the installation costs. For the Rollins College application, value engineering indicated that a singlefan configuration provided adequate performance and was a better choice economically. Controls Temperature control in the audito- Circle 174 38 March 2008 HPAC Engineering Circle 175

Two of the six server racks in the Bush Science Center server room. Two of the four ceiling diffusers from AHU-3 are visible above. rium of Bush Science Center is provided by a thermostatic sensor that first modulates the variable-air-volume (VAV) box as in a conventional system. Under low loads, the VAV box tends to close, so a carbon-dioxide (CO 2 ) sensor in the auditorium overrides the damper position to ensure enough fresh air is being delivered. The VAV box Cubic feet per minute 3,500 3,000 2,500 2,000 1,500 1,000 500 0 Supply-air control range. 0 20 Supply-air temperature modulates open and closed to maintain a differential CO 2 level of less than 700 ppm between the indoors and outdoors. If the auditorium is overcooled because of the opening VAV box, the hot-deck and cold-deck dampers in the AHU modulate to meet the auditorium set-point temperature by mixing data-center air with the 40 50 60 Damper position, percent Bypass-damper airflow 80 100 90 80 70 60 50 40 30 20 Degrees Fahrenheit air. Humidity control is activated when the auditorium s level exceeds 60-percent relative humidity. Excess humidity causes the hot-deck damper to modulate open, increasing the temperature and lowering the humidity of the auditorium s air. The temperature of the air flowing to the auditorium has a wide range of capability, from 54 F (without the mixing of warm and chilled air) to higher than 80 F (with full chilledwater- bypass). This is achieved without the use of new energy for reheat, using only the heat collected from the computer-server equipment. The -fan VFD speed is varied to achieve the duct-static-pressure set point, and the -air leaving temperature is designated according to a reset schedule, as in a conventional configuration. Smoke detectors in the -air ducts, data-server room, and underfloor air plenum de-energize the fan and close the hot-aisle ceiling fire dampers. Temperature in the data-center office is controlled via a plenummounted fan-powered mixing box that mixes cold air from the third AHU (AHU-3) with air from the data-server hot aisle to meet the office temperature set point. To reduce the number of potential failure points, there is no temperature control in the data-server area fully chilled air is delivered at all times directly from the air handler to the underfloor plenum and the VFD is equipped with an external bypass in case of failure. The original 15-ton DX system is used as a backup controlled by a simple wall thermostat set to 78 F. A humidity sensor in the data-server area is used to alarm the facility manager via pager and e-mail if humidity is outside of the 30- to 70-percent range, which would indicate an under- or overcooling situation. The data-center -air plenum connects to the auditorium West FIGURE 6. 40 March 2008 HPAC Engineering (Size: 27 picas.)

duct via the air-handler filter-mixing module. Potential sound pathways from server fans and power supplies were addressed. Sound levels in the server room reach 79 db when the fans are at full speed, while the auditorium classroom has a design criterion of Noise Criteria- (NC-) 30. An acoustic baffle and 2-in.-thick sound liner with an acoustical value of Noise Reduction Coefficient- (NRC-) 0.95 in the plenum achieve noise control in the auditorium -air path. Two sound attenuators isolate noise of the auditorium ductwork from the data servers. Conclusion Exhaust from the hot aisle of a server room can be utilized effectively for reheat when required (based on the number of servers and size of each server in a project). It is important to study the airflow requirements and SHR for each Eight raised-floor diffuser tiles provide 3,360 cfm; ceiling-diffuser design airflow is 850 cfm. Nominal design server heat load is 48 kw, with 54 F air, 74 F average space air, and 90 F hot-aisle exhaust. Circle 177 HPAC Engineering March 2008 41

Data Outside air Filter angled mixing Filter angled Variable-Frequency Drive 1 Hot deck Variable-Frequency Drive 2 Cold deck of the spaces conditioned by a common air-conditioning system under various load conditions to evaluate and design the most optimized system. Higher -air exchange rates in a server room would result in more uniform Heating (small, ½-in. tube, two-row) Cooling (medium/large with access, ½-in. tube, six-row) West FIGURE 4. (Size: 27 or 41 picas.) Data A dual-fan hot-deck/cold-deck air-handler module configuration provides virtually unlimited flexibility and dehumidification capability. Increased complexity and the costs of two fans, VFDs, and additional control points can be justified for projects in which static pressures do not balance naturally and/or reheat needs are high. cooling. This can be used effectively for humidity control in an adjacent space. Even though humidity control can be achieved by varying the airflow rates and maintaining a constant -air temperature, minimum airflow rates dictated by ventilation codes demand some form of reheat for comfort control, especially in hot and humid climates. Based on cost, space limitations, and ductwork constraints of the existing systems, mixed-air bypass was selected for the Rollins College project. Return-air bypass with an additional fan also can be used effectively for better humidity control in new designs with this approach. The mixed-air bypass has been in successful operation and meeting the temperature and humidity-control requirements of the auditorium and data center for more than a year. Utilizing a well-defined sequence of operations and a dedicated control system is key to achieving success in such designs. For past HPAC Engineering feature articles, visit www.hpac.com. 42 March 2008 HPAC Engineering Circle 178