HERZ-Thermal Actuators



Similar documents
EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

E-STOP relays, safety gate monitors

Electric Rotary Actuator - On/Off or programmable control actuator

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

J TB/TW Temperature limiter, temperature monitor

RRV934. Multi-controller. Synco living

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM. Serial number: Year: --- Page 1

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Safety automation solutions

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

38 Series - Relay interface modules A

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Product and functional description

Heating Controller. Building Technologies HVAC Products

MasterINTERFACE 39 Series - Relay interface modules

RY2 miniature industrial relays

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

HCE80/HCC80/HCE80R/HCC80R

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Vario-Series Accessories

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Pluggable interface relays CR-P Pcb relays

Maximum Demand Control

Quick Connect. quick - simple - efficient.

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

38 Series - Relay interface modules A

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

ELECTRIC CENTRAL HEATING FLOW BOILER

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Air damper actuators

Multi-Range Programmable DC Power Supplies 9115 Series

MasterINTERFACE 39 Series - Relay interface modules

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Flush-mounted room thermostats

PNOZsigma - Base units

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Drayton Digistat +2RF/+3RF

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

ACS-30-EU-EMDR-10-MOD

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Operating Instructions. Room temperature controller

Safety Relays ESM/ESM-F

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Assisted lift operated 2/2-way solenoid valves Type EV250B

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

48 SERIES Relay interface modules 10 A

Proportional pressure regulators VPPE

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

SKR - industry relay

R.C.C.B. s two-pole LEXIC

TS93 EMR T/PT/TDE. Surface applied door closer

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Cable Plug acc. to DIN EN , Form A

Digital inductive conductivity transmitter

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

CONFIGURABLE SAFETY RELAYS

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

13 SERIES. Electronic step relays A

MOUNTING AND OPERATING INSTRUCTIONS

Product and Application Description

80 Series - Modular timers 16 A. Features

Safety technique. Emergency stop module BO 5988 safemaster

Transmitter Actuator 230V wave UP 560. Operation

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

T5000 T000 LCD Digital Fan Coil Thermostat

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Air conditioning, electrical testing

RF 1. Contents: Connecting diagram. Detailed information:

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Thermistor motor protection

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Voltage Regulator SPAU 341 C. Product Guide

Material test chamber with mechanical convection

Transcription:

HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01 1 7710 50 1 7710 51 Thermal Actuator Models 1 7710 00 HERZ- Thermal Actuator M 28 x 1,5,, 50 Hz with normaly closed contact (NC), can be switched to normaly open contact (NO), M 28 x 1.5. 1 7710 01 HERZ- Thermal Actuator M 28 x 1,5, DC with normaly closed contact (NC), can be switched to normaly open contact (NO), M 28 x 1.5. 1 7711 18 HERZ- Actuating drives for continuous control, M 30 x 1,5, DC Thermo-electronic continuous drive, 3-conductor connection cable, operating voltage, driving voltage 0-10 V DC. 1 7710 80 HERZ- Thermal Actuator M 30 x 1,5,, 50 Hz with normaly closed contact (NC), can be switched to normaly open contact (NO), M 30 x 1,5 1 7710 81 HERZ- Thermal Actuator M 30 x 1,5, DC with normaly closed contact (NC), can be switched to normaly open contact (NO), M 30 x 1,5 1 7711 80 HERZ- Thermal Actuator M 30 x 1,5,, 50 Hz For HERZ-thermostatic valves 1 7760, 1 7762 and 1 7763; with normaly closed contact (NC), can be switched to normaly open contact (NO). M 30 x 1,5 1 7711 81 HERZ- Thermal Actuator M 30 x 1,5, DC For HERZ-thermostatic valves 1 7760, 1 7762 and 1 7763; with normaly closed contact (NC), can be switched to normaly open contact (NO). M 30 x 1,5 1 7990 00 HERZ- DDC- actuating drive M 28 x 1,5, AC Thermo-electronic continuous drive, 3-conductor connection cable. Operating voltage, driving voltage 0-10 V DC, 100kΩ M 28 x 1,5 Page 1

1 7710 50 HERZ- Thermal Actuator M 28 x 1,5,, 50 Hz with normaly closed contact (NC), can be switched to normaly open contact (NO), M 28 x 1.5, Installed with auxiliary contact (1 changeover contact). 1 7710 51 HERZ- Thermal Actuator M 28 x 1,5, DC with normaly closed contact (NC), can be switched to normaly open contact (NO), M 28 x 1.5, Installed with auxiliary contact (1 changeover contact). 1 7708 11 * HERZ- Thermal Actuator M 28 x 1,5,, 50 Hz with normaly closed contact (NC), M 28 x 1.5. 1 7708 10 * HERZ- Thermal Actuator M 28 x 1,5, DC with normaly closed contact (NC), M 28 x 1.5. 1 7710 55 Auxiliary contact For actuating drives 1 7710.., for retro fitting. 1 7708 23 HERZ- Thermal Actuator M 28 x 1,5,, 50 Hz with normaly closed contact (NC), M 28 x 1.5. 1 7709 01 HERZ- Thermal Actuator M 28 x 1,5,, 50 Hz with normaly open contact (NO), M 28 x 1.5. Application 7710/7711/7708/7709 HERZ thermal actuators are electrothermal actuating drives for 2-point control in heating and cooling systems to be installed with a thermostat. They are particularly suitable for zone control and for floor heating systems. HERZ thermal actuators can be used with all HERZ valves with M 28 x 1.5 (7710) or M 30 x 1.5 (7711) equipped for thermostatic operation. Rating of auxiliary switch when used with direct current: 4...30 V, 1...100 ma 1 7711 18 HERZ thermal actuators are electrothermal actuating drives for continuous drive control in heating and cooling systems to be installed with a thermostat. They are particularly suitable for zone control and for floor heating systems. HERZ thermal actuators can be used with HERZ valves with M 30 x 1.5 equipped for thermostatic operation. 7990 HERZ thermal actuators are electrothermal actuating drives for continuous drive control in heating and cooling systems to be installed with an Electronic Control System for Modulating Control. The output signal is then allocated linearly to the effective stroke. HERZ thermal actuators can be used with HERZ valves with M 28 x 1.5 equipped for thermostatic operation. Function 7710/7711 The thermal drive is actuated by an external contact, e.g. from a room thermostat, and starts to open or close the valve. The actuating movement is achieved by means of an electrically heated expansion element. When the heating current is switched off, the actuator shuts or opens the valve. The HERZ actuating drive is maintenance free and works silently. 1 7711 18/7990 The actuator has an electrically heated, overload-proof expansion element which transfers its stroke direct to the valve. It works silently and requires no maintenance. When the heating element is switched on from cold, the valve (after a warming-up period of about 80 seconds) starts to open, reaching the maximum stroke of 4,5 mm after about 85 seconds. When the drive is regulating, a movement of 1 mm is carried out in about 30 seconds; the stroke is monitored by a Hall sensor. The closing operation is similar (with regard to time) to the opening operation: the expansion element cools down and the valve is closed by spring pressure. Changing the 7710/7711 The HERZ thermal actuator is factory set to closed without current. By pulling out a plug-in component, the operating mode can be changed to open without current. In this operating mode, the thermostatic valve is closed when the expansion element is heated, and opened when it cools down. How to change the operating mode is described and shown in a graph in the instruction sheet supplied with the device. Emergency Operation When the thermal actuator is in the factory-set operating mode closed without current, the valve can be opened by removing the actuating drive in case of power failure. Special Design Features The actuating drive is mounted onto a plastic base and equipped with a plastic cover. There is no metallic connection between the actuating drive and the valve. The drive is mounted onto the valve by means of a knurled nut. * Germany only Page 2

Installation Before working on the device shut off the power. The connection may be made only by an authorized person. The connection must be made according to the attached wiring diragram. The device is intended for connection to fixed cables in closed and dry rooms. When installing, make sure that voltage-carrying lines, power supply and relay connection lines, do not come into contact with low-voltage cables, such as sensor wires (minimum distance of 4 mm at base insulated conductors). Provide sufficient protection against independent release of all connecting conductors according to EN60730, part 1 requirements. Note the VDE 0100, EN 60730, Part 1, and the rules of the local power company. If the device does not work, first check the correct connection and the power supply. Incorrect connection may damage the regulator! Damage caused by incorrect connection and / or improper handling will not be covered by the warranty! Installation of the Thermostatic Valve The flow direction must be in accordance with the arrow on the valve body. Avoid installing the actuating drive below the valve spindle axis. Drops of water might penetrate the actuating drive and impair its functioning. Installation of the Thermal Actuator 7710/7711 Remove the screw cap or handwheel from the valve. The valve is completely open. Place the thermal actuator in the desired position at the centre of the valve body and press it onto the front side. Subsequently, turn the knurled nut clockwise and fasten by hand. Installation of the Thermal Actuator 7980/7990/7708/7709 After screwing the adapter ring on the valve, the actuator is mounted and locked (click). After pressing the button, the actuator can be removed. The valve adapter should be mounted on the valve when the valve is fully open. The actuator is mounted and wired, but not under tension. This state corresponds to the function normally open and allows pipe flushing, sample heating. When power is applied to the actuator for the first time the operating status will be closed as per factory settings. At the head of the actuator a function display is provided. The valve is in the open position when the blue field is visible. Technical Data Order Number 1 7710 00 1 7710 01 Nominal Voltage Power supply AC/DC w 15%, 50-60 Hz. w 20% Max. Input Current 250 ma 250 ma Operating Power 2,5 W 3 W Input 58 VA 6 VA normaly closed contact (NC), can be switched to normaly open contact (NO) app. 3 min. Ambient Temperature -5 to 50 C < 95 % rf Degree IP 42 (EN60259), vertical IP 44 0,2 kg Page 3

Order Number 1 7710 80 Nominal Voltage Power supply AC/DC w 15%, 50-60 Hz. Max. Input Current 250 ma Operating Power 2,5 W Input 58 VA normaly closed contact (NC), can be switched to normaly open contact (NO) app. 3 min. Ambient Temperature -5 to 50 C < 95% rf Degree IP 42 (EN60259), vertical IP 44 0,2 kg Connection Thread M 30 x 1,5 Order Nubmer 1 7710 50 (with auxiliary contact) 1 7710 51 (with auxiliary contact) Nominal Voltage Power supply AC/DC w 15%, 50-60 Hz. w 20% Max. Input Current 250 ma 250 ma Operating Power 2,5 W 3 W Input 58 VA 6 VA normaly closed contact (NC), can be switched to normaly open contact (NO) app. 3 min. Ambient Temperature -5 to 50 C < 95% rf Degree IP 42 (EN60259), vertical IP 44 0,2 kg The auxiliary contact can be connected to e.g. a circulating pump, with the contact switch between 35% and 50 % stroke. the output of the contact is 3 A for resistive load and 2 A for inductive load. The contacts close when the stroke reaches 35% or 50%. Order Nubmer 1 7711 80 1 7711 81 Nominal Voltage Power supply AC/DC w 15%, 50-60 Hz. w 20% Max. Input Current 250 ma 250 ma Operating Power 2,5 W 3 W Input 58 VA 6 VA normaly closed contact (NC), can be switched to normaly open contact (NO) app. 3 min. Ambient Temperature -5 to 50 C < 95% rf Degree IP 42 (EN60259), vertical IP 44 0,2 kg Connection Thread M 30 x 1,5 Page 4

Order Number 1 7990 00 Nominal Voltage Power supply AC/DC AC -10% +20% Max. Input Current 0-10 V DC Operating Power 1,5 W Input 100 kω normaly closed contact (NC) 30 s/mm Ambient Temperature -5 bis 50 C < 95% rf Degree IP 40 (EN60259) 97 g Order Number 1 7708 11 1 7708 10 Nominal Voltage Power supply AC/DC, +10%...-10%, 0-60 Hz, +20%...-10%, 0-60 Hz Operating Power 2 W 2 W normaly closed contact (NC) 3 min Ambient Temperature 0-50 C max. 80% 0-100 C Housing Plastic, white RAL 9010 Degree IP 40/ II (EN60259) 73 g Nominal Voltage Power supply AC/DC Max. Input Current Operating Power Order Number 1 7708 23 1 7709 01 AC ±10% 50-60 Hz 300 ma 1,8 W normaly closed contact (NC) normaly open contact (NO) ca. 3 min any position Ambient Temperature 0 to 60 C max. 100% Housing Plastic, white RAL 9010 Degree IP 54 / II 97 g Page 5

Room Thermostat 7710/7711/7708/7709 Any conventional room thermostat with thermal offsetting can be used to control the HERZ thermal actuator. If required, several drives can be connected in parallel, depending on the electric rating of the switching contact. 7990 In connection with the HERZ RTC Room Temperature Computer 1 7940 62 or any other controller with continuous output 0-10 V. The actuator must not be opened. Be installed for long connecting cables must have a connection box. Sizing and Installation When selecting the switching contacts and sizing the mains fuses, the input current of the heating element must be taken into account. The voltage drop through the electric cable must not exceed 10% in order to maintain the specified operating time. The table below shows the maximum cable lengths for a thermal actuator for the specified conductor cross sections (in a cable according to specifications, the voltage drop is approx. 5%, at the voltage drop is 10 V, at the voltage drop is 1 V). When using several thermal actuators, the specified cable length must be divided by the numberof thermal actuators connected. Cable cross-section (mm 2 ), max. Lenght (m), max. Lenght (m) 2 x 0,75 1500 168 2 x 1,0 2000 224 2 x 1,5 3000 340 2 x 2,5 5000 560 Resistance Values The resistance values for HERZ-valves when operating with HERZ actuators can be found in the HERZ standard diagrams of the respective data sheets. Accessories 1 7796 02 HERZ-transformer 230/ The overload-proof security HERZ transformer 230/ is provided for connecting a HERZ-thermostats and HERZ engines and is designed for the operation of up to 8 HERZ actuators. Execution According to VDE 0551 Protection Class II Degree IP 20 ISO Kl. T40/E Input Voltage Input circuit fuse 50-60 Hz, 315 ma Output Voltage Power rating 50 VA Quick mounting on Equipment rail wg DIN 42227/3 Dimensions 106 x 90 x 74 mm (W x H x D) 1 7940 62 HERZ-RTC-Room Temperature Computer With 3 weekly programmes, 4 temperature steps, vacation programme for heating and cooling, switching difference adjusting. Set value range 5-40 C, operating voltage, output voltage 0-10 V. 1 7791 23 HERZ- Electronic Room Temperature Controller for 2-Point or Pulse Control with digital timer For individual time and temperature programmable adjustment. Digital timer with program on a weekly and yearly basis, automatic switching between summer and winter time. Set value range 8-38 C. Switching difference as 2-point controller 0.4-8 K. Metering precision 0.3 K at a temperature of 20 C. 1 7791 02 HERZ- Electronic Room Temperature Controller for 2-Point or Pulse Control with digital timer Design as 1 7791 23, but operation by 2 alkalimanganese penlight type round cells (AA) 1.5 V, not included in package. Page 6

1 7790 15 HERZ- Room Temperature Controller for 2-Point Control, 50 Hz 1 change-over contact Set value range 10-30 C. Switching difference ± 0.2 K fi xed 1 7790 25 HERZ- Room Temperature Controller for 2-Point Control DC 1 change-over contact Set value range 10-30 C. Switching difference ± 0.2 K fixed 1 7794 23 HERZ- Electronic Room Temperature Controller with PI control For heating and cooling operation, with programmable time and temperature settings. Outlets for motor (3-point) and thermal drive and pump or fan (on/off signal). Fix basic programme (preset condition) for first start-up. Easy adjustment to system by selecting 8-basis control model by service parameter. Electronics located in the attachable body, white (RAL 9010), front with digital display in viewing window. Digital timer with weekly and yearly programme, relay with elapsed time indicator. For installation on a wall or flush-mounting socket. Wiring Diagram 3 F798 00 HERZ- Electric Distribution Panel for Actuating Signals For distribution of electric signals and for power supply of control devices and actuating drives. The switch impulse of the room temperature controller is individually passed to the actuating drivers. Plastic body, white RAL 9010, with integrated fuse 4 A, over voltage protection for actuating drives, pump connection with earthed conductor and temperature limiter, pump logistics as needed ( or ) with volt-free contacts available as accessories. Electrical connections with screw clamps max. 1.5 mm². 2 1 7791 02 1 7791 23 1 7710 01 1 7710 51 1 7791 02 1 7710 01 1 7710 51 1 7791 23 1 7796 02 1 7796 02 1 7710 00 1 7710 50 1 7710 00 1 7710 50 Page 7

Number of actuators that can be connected to one controller HERZ Actuator HERZ Controller 1 7790 15 1 7790 25 1 7790 00 1 7791 23 1 7791 02 3 V 1 7794 23 1 7794 24 1 7940 62 1 7710 00 8-10 8 8 - - - 1 7710 01-8 - - 8 - - - 1 7710 80 8-10 8 8 - - - 1 7710 81-8 - - 8 - - - 1 7710 50 8-10 8 8 - - - 1 7710 51-8 - - 8 - - - 1 7990 00 - - - - - - - 6 1 7711 18 - - - - - - - 24 1 7711 80 8-10 8 8 6 - - 1 7711 81-8 - - 8-3 - 1 7708 11 > 20 - > 20 > 20 > 20 - - - 1 7708 10 - > 20 - - > 20 - - - 1 7708 23 8-10 8 8 - - - 1 7709 01 8-10 8 8 - - - Accessories: Adapter blue 1 7708 85 M 28 x 1,5 for 4002, 4006, 7217 TS-V Adapter grey 1 7708 80 M 28 x 1,5 for 7217 TS-E Adapter grey 1 7708 98 M 30 x 1,5 for 7760, 7762, 7763, TS-90-H, TS-98-VH Page 8