basicdim DGC Compact control module



Similar documents
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Operating instructions II / 2004

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

Operating instructions IV / 2007

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

Emergency lighting units EM powerled

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Busch-Watchdog Presence EIB Type:

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP )

DALI RC BASIC SO. Control unit Operating instructions

EBDSPIR-DD, EBDSPIR-DD-IP

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

EBDSPIR-PRM, EBDSPIR-PRM-IP

13 SERIES. Electronic step relays A

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series

LED control gear. LED control gear

connecdim Gateway G1 Ethernet TCP/IP to DALI

Product and functional description

ACS-30-EU-EMDR-10-MOD

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Safety technique. Emergency stop module BO 5988 safemaster

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

Electronic Control Devices The European Product Catalogue 2007

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

15 Series - Electronic step relay and dimmer. Features SERIE

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Inwall 4 Input / 4 Output Module

KNX Lighting Control System

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Lighting Management solutions

HERZ-Thermal Actuators

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Transmitter Actuator 230V wave UP 560. Operation

How To Use A Power Supply On A Powerline 2.2 (Ai)

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Inwall Room Temperature Unit

PHOENIX CONTACT Features

Electronic Control Devices The European Product Catalogue 2007

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Quick Connect. quick - simple - efficient.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

ABB i-bus KNX SA/S Switch Actuators Product Manual

500r+ Installation and User Guide

ABB i-bus KNX Fan Coil Controller FC/S 1.1

FIRERAY 2000 Installation Guide

Digital input modules

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Operating instructions

PART 1 PRODUCT (GENERAL)...1.

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

SZI IR Audio Transmission Technology Modulators/Radiators

DALI Driver Configurator User Guide

Industrial Linergy LED

Cross-beam scanning system to detect slim objects. 100 mm in

Actuator for modulating control AME 435

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR

CONFIGURABLE SAFETY RELAYS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Heating, air-conditioning, cooling

Medical Lighting. XL4 Patient Light

ABB i-bus KNX DALI-Gateway DG/S 8.1

Preset Counter signo 721

How To Read A Pipe From A Sensor

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

instabus KNX / EIB System System E F G H

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Electrical connection

T7560A,B,C Digital Wall Module

ABB i-bus EIB Logic Module LM/S 1.1

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

STERILIZERS, LABORATORY DRYING OVENS

Unica for KNX system 226

Controlers. Controler

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

MINI MCR-SL-R-UI(-SP)

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Transcription:

luxctrol lighting control sstem DGC Compact control module Product description Compact dimensions for luminaire installation For up to 0 DSI or LI ballasts ( per output channel) LI IN input LI/DSI output channels with adjustable offset from channel to channel 1 1 relais output Sensor input for up to DGC sensors 5DPI 1 switch inputs for on/off switching and dimming Individual adjustment of the parameters with DGC Programmer or software mastercfigurator 5-ear guarantee È Wiring diagrams and installation examples, page 9 www.tridonic.com 1

luxctrol lighting control sstem DGC Compact control module Technical data Rated suppl voltage 0 0 V Mains frequenc 50 / 0 Hz Power.5 W Stand-b power 0.5 W Operating temperature 0... +0 C Storage temperature -5... +0 C Tpe of protection IP0 Max. casing temperature tc 0 C 159 1 150 0 1 0 Ordering data Tpe Article number Mounting Packaging carton DGC 800090 Luminaire installation 10 pc(s). Specific technical data Tpe Inputs Outputs CH as Link Line Output, rela (L ) Dimming Max. cable Max. Max. sensor Digital control Control output Dimming Maximum Voltage DC Maximum Number of Max. switching Maximum Max. switch length at DGC sensors line length at line LI/DSI per phsical range cable length cable length combinable output (e.g. apparent switching 1.5 mm² 0. 1.5 mm² output (devices) at 1.5 mm² at 1.5 mm² modules ) power output DGC double 100 m 10 m 10 1 100 % 100 m 1 V 100 m 10 00 VA 500 W www.tridonic.com

luxctrol lighting control sstem ACCES- SORIES DGC Sensor 5DPI 1f Product description Light measurement and motion detection Up to DGC sensors on one DGC Can be remote controlled Light measurement and motion detection can be deactivated Individual adjustment of the parameters with DGC Programmer or software mastercfigurator Power suppl via DGC Technical data Ø of detection range, mounted at a height of.5 m m Swivel design no Detection angle 0 Light measurement at the sensor head 1 10 50 lx Infra-red control range 5 m Max. mounting height 5 m Operating temperature 0... +50 C Storage temperature -5... +55 C Tpe of protection IP0 1 The measured value at the sensor head corresponds to approx. 15 to,000 lux on the surface measured. 1,8, Ø1,9 1,9 1, Ordering data Tpe Article number Packaging, carton Sensor 5DPI 1f Luminaire installation 80009 0 pc(s). www.tridonic.com

luxctrol lighting control sstem ACCES- SORIES DGC Sensor 5DPI 1rc Product description Light measurement and motion detection Up to DGC sensors on one DGC Can be remote controlled Light measurement and motion detection can be deactivated Individual adjustment of the parameters with DGC Programmer or software mastercfigurator Power suppl via DGC Technical data Ø of detection range, mounted at a height of.5 m m Swivel design no Detection angle 0 Light measurement at the sensor head 1 10 50 lx Infra-red control range 5 m Max. mounting height 5 m Operating temperature 0... +50 C Storage temperature -5... +55 C Tpe of protection IP0 5,5 5, 1 The measured value at the sensor head corresponds to approx. 15 to,000 lux on the surface measured. Ø,5 Ø58 18 Ordering data Tpe Article number Packaging, carton Sensor 5DPI 1rc Ceiling installation 80009 pc(s). www.tridonic.com

luxctrol lighting control sstem ACCES- SORIES DGC Programmer Product description Optional infra-red programming unit for DGC Setting of predefined discrete parameter values Programmable functions such as light level, time dela, P.I.R., bright-out, power up Ordering data Tpe Article number Dimensions L x W x H Packaging carton DGC Programmer 8000 10 x 5 x 15 mm 1 pc(s). ACCES- SORIES REMOTECTROL IR Product description Optional infra-red remote control Switching on and off (On/Off button) Dimming (Up/Down button) Activation of automatic lighting control Setting the threshold control point (Set button) Ordering data Tpe Article number Dimensions L x W x H Packaging carton REMOTECTROL IR 8000 8.5 x 0.5 x. mm 500 pc(s). www.tridonic.com 5

luxctrol lighting control sstem ACCES- SORIES Strain-relief set Product description 5-ear guarantee 1 50 Ordering data Tpe Article number Packaging carton Strain-relief set 8000881 10 pc(s). www.tridonic.com

luxctrol lighting control sstem DGC The basic DIM DGC provides the basis for an eas-to-use and cost-effective lighting sstem with motion detection. When the sensor detects movement it triggers a individual adjustable motion detection profile in the control unit. As the amount of natural ambient light changes the illuminance from the artificial lighting sstem is adjusted. The connected luminaires can be switched on and off via momentar-action switch or remote control possible. The LI IN interface allows integration of the DGC module also into a comfortdim sstem. The DGC module has 5 preprogrammed profiles which can be selected using the DGC Programmer. The profiles can be adjusted to our application via the mastercfigurator ( V.1) software. If the DGC module is used in the basic application, the CH can be used as control channel for controlling subordinate DGC modules (basic connection), so that the controlling and the subordinate DGC modules can be programmed and allocated to groups using the mastercfigurator software. Ever single DGC module can be allocated to a group and respond to the presence of up to 5 groups (for more detailed information please refer to the mastercfigurator documentation). Standards EN 55015 EN 1000-- EN 1-1 EN 1--11 EN 15 EN 8-101 EN 0598-1 EN 9 Glow-wire test according to EN 1-1 passed. LI standard The DGC is designed to control control gear with LI standard IEC 099 (LI V0) and IEC 8 (LI V1). Installation DGC can be operated without sensor. The motion detection must be disabled via mastercfigurator or with unique connecting a sensor and DGC Programmer. DSI/LI is not SELV. The installation instructions for mains voltage therefore appl. The maximum cable length between the external switch and DGC is 100 m. The maximum cable length between the sensor and DGC is 10 m. A snchronous operation of LI and DSI ballasts at the same control gear is not possible. The output channels (for a cable cross-section of 1.5 mm ) must not be exceeded 100 m. If CH is used as link line, the maximum cable length must not exceed 100 m (at 1.5 mm²). If a DGC is connected to CH, LI IN is disabled and CH is used as Link-Line (neighbourhood function). No control commands are transmitted via CH, to reactivate LI IN see DGC manual. An number of push to make switches ma be connected in parallel to the inputs. Do not connect standard switches to the input. Please ensure that the detection range of the sensor lies in the lighting area of the controlled luminaires. Heaters, fans, printers and copiers located in the detection zone ma cause incorrect presence detection. To avoid false readings, the sensor should be installed so there is no direct light from the lamp in the detection zone. Sensor wires must be routed separatel from the lamp wires and mains cables otherwise the lighting control sstem ma malfunction. If separate routing is not possible (for reasons of space) shielded lamp wires and mains cables must be used. www.tridonic.com

luxctrol lighting control sstem DGC sensor Light level recognition area Presence / motion detection Sensor alignment x Example for light and motion detection area at height of 1. m: x x1 x1 1 m α x = α x1 = 8 α = 0 h α = 8 h h 0. m x x1 1. m 8 Light level recognation area x x x1 x1 x 1 m Presence / motion detection.8 m d x1 h * x1 x d 1. m 1. m 0. m 1.0 m.8 m.0 m 1. m 0.8 m 1. m. m. m 1.8 m 0.9 m 1. m. m.5 m.0 m 1.0 m 1. m.0 m. m.1 m 1.1 m 1. m. m.0 m. m 1. m 1. m.9 m.5 m. m 1. m.0 m 5. m.0 m.1 m 1. m. m.5 m * The recommended maximum room height for office applications is m and for corridor applications for example m. Up to m mounting height presence is detected and over m motion is detected. Calculation of the diameter (light area): x1 = tan(ax1) h x = tan(ax) h = tan(a) h Calculation of the diameter (motion area): d = tan(0,5 a) h Mounting variants luminair installation sensor Size of the sheet: 0.8 1.8 mm Size of the sheet: 0. 0.8 mm 1,5,5 19,1 ø1,1 +0, 0, +0, 0 +0, 0 0 +0,1-0,1 ø1,8 +0,1 0, 0-0,15 Size of the sheet: 0.8.0 mm, 5,5 1,1 +0, 0 1,1 +0, 0 R1,9 0-0, www.tridonic.com 8

luxctrol lighting control sstem Wiring diagram DGC LI L N DGC Sensor * L N L LI IN max. 500 W (L') max. DGC e Sensor ed CH1 D CH D max. DGC * must be the same phase as for L basic L N DGC Sensor max. * L N L ** LI IN DGC e Sensor ed *** CH1 D CH D DGC Sensor LI USB * L N L ** LI IN DGC e Sensor ed CH1 D CH D max. * must to be the same phase as for L ** can be connect with loads up to 500 W, as shown in the wiring for LI *** if a DGC is connected to CH, LI IN is disabled and CH is used as Linke-Line (neighbourhood function). No control commands are transmitted via CH, to reactivate LI IN see DGC manual. www.tridonic.com 9

luxctrol lighting control sstem Relais in standb L N L DGC Sensor The inrush currents of the control gears must be taken into account when dimensioning the contactor. * L N L LI IN DGC e Sensor ed CH1 D CH D max. max. DGC * must be the same phase as for L Wiring tpe and cross-sections for DGC Solid wire with a cable cross-section of 0.5 mm² to 1.5 mm². wire preparation: 0.5 1.5 mm² 8.5 9.5 mm LI IN The LI IN interface allows integration of the DGC module also into a comfortdim or other BMS sstems. However, not all LI commands are supported. The LI commands supported are listed in the operating instructions. B using the DGC in basic configuration (additional DGC s connected to CH) LI IN interface will be deactivated. Wiring tpe and cross section Sensor 5DPI 1rc The wiring can be solid wire or stranded wire with a cross-section of 0. mm² to 1.5 mm². wire preparation: 0. 1.5 mm².5 8.5 mm Wiring tpe and cross section Sensor 5DPI 1f The wiring can be solid wire or stranded wire with a cross-section of 0. mm² to 0.5 mm². wire preparation: 0. 0.5 mm² LI/DSI output channels CH1 - CH The output channels can be set to DSI or LI (default) using the DGC Programmer or the mastercfigurator software. After mains failure the DGC will set new the following parameters to CH1/CH: POWER LEVEL SYSTEM FAILURE LEVEL FADE TIME MIN LEVEL MAX LEVEL For more detailed information please refer to the manual..5 8.5 mm www.tridonic.com 10

luxctrol lighting control sstem Switch DGC has two inputs ( and ) for two external switches. An number of switches can be connected in parallel to the inputs (parallel connection of and possible). Short press (< 500 ms): Long press (> 500 ms): / Dim up/down A change in the light value deactivates lighting regulation onl temporaril. As soon as the luminaire has been automaticall switched on again (motion detection) or manuall switched off and on again, regulation is activated again. x short press: The overwritten setpoint light value is stored (luminaire acknowledges b flashing twice) Function is lockable via the DSI programmer Different output channels are controlled, depending on the profile selected. Relais The rela can be used in four different operating modes: Reduction of standb losses (standb wiring example) Independent output channel for switching non-dimmable luminaires (LI wiring example) Depending on the profile used, the rela will respond differentl. For the 5 main profiles, the two rela profiles used are Standb and Onl. The mastercfigurator software allows to enable or disable the rela profiles as well. Standb Onl Standb Onl Energ saving mode If the DGC module is switched off, the rela will switch off (after 10 minutes). If the DGC is switched on, the rela will switch on. Switching: rela in standb mode The rela must be switched on using the momentar-action switch, but is switched off b the presence detector. Active Inactive The rela is switched on or off via the presence detector. The rela must be switched on and off using the momentar-action switch. www.tridonic.com 11

luxctrol lighting control sstem Depending on the profile used, different operating modes are preprogrammed for the presence detector. These can be changed using the DGC Programmer or the mastercfigurator software. onl Run-on time / Onl Never 1min 10min 0min AUTO CH CH1 0 % 0 % The light is switched on and off automaticall based on the presence/absence of people. The presence detector just switches the connected luminaires off. The luminaires are switched on manuall via the connected external momentar-action switch or the remote control. If no presence is detected, the sensor dims down to the second light level parameter and maintains this setting. Presence detector disabled. The light must be switched on and off manuall. Run-on time of the presence detector, run-on time starts when no presence is detected. The run-on time ma var depending on the profile used. You can choose whether ou want the DGC module to switch off the light completel or to dim it down to the absence value after the run-on time. It can also be changed using the DGC Programmer or the mastercfigurator software. Absence value 1% 10% 0% Switch-off dela 0min 1 min 0min The absence value (light level) and the switch-off dela (the period for which the level is maintained) differ depending on the profile used; these parameters ma be changed using the DGC Programmer or the mastercfigurator software. Offset - 0% Depending on the profile used, a negative offset ma be enabled between CH and CH1. Using the DGC Programmer and the mastercfigurator software, this parameter ma be changed (also positive offset possible). 500 LUX Artificial light Natural light Manual-off dela 1min Set target value SET The light level can be set via following options: REMOTECTROL IR (press the ke for > s) DGC Programmer (press the ke for > s) mastercfigurator software external momentar-action switch: SET B briefl pressing the momentar-action switch twice the currentl measured light level is saved as new target value. (Depending on the profile used, this function is enabled or disabled, but it can be changed using the DGC Programmer or the mastercfigurator software) Bright-out If the nominal illuminance level (e.g. 500 lx) is exceeded for 10 minutes at over 150 % (e.g. 50 lx), the light is switched off, even if presence is detected. The light is switched on again as soon as the measured light level falls below the target value. Depending on the profile used, this function is either enabled or disabled and can be changed using the DGC Programmer or the mastercfigurator software. The bright-out status can be indicated on the sensor b a slowl flashing green status LED. B default this function is disabled, but it can be enabled using the mastercfigurator software. CH1 CH 10 min If the light is switched off manuall via momentar-action switch or remote control, the presence detector is disabled. After a period of dela without an presence detected, the presence detector is enabled again. If the sensor detects presence during the Manual Off dela, the dela time will start all over again. Lighting control AUTO Lighting control is started via the Auto ke of the Programmer or REMOTECTROL IR. If the DGC module has been switched on via the ke, lighting control is disabled. If ou want to use lighting control, ou need to start the DGC module via the Auto ke. Lighting control can also be disabled using the mastercfigurator software. Light control incl. brightout activated for CH1. CH is not illuminated controlled. www.tridonic.com 1

luxctrol lighting control sstem Neighbourhood function Depending on the profile used, the DGC can respond to presence detected in other groups. These functions can be changed using the DGC Programmer or the mastercfigurator software. Switched off Switched on No response to presence detected in other groups. Default setting for all profiles! If presence is reported b other groups, the light level will switch to presence value Behaviour after return of power The DGC module features two different tpes of starting behaviour after mains failure. Power behaviour (luminaires remain switched off) Power behaviour (the luminaires are switched on after return of power). Default setting for all profiles! Switched on If presence is reported b other groups, the light level will switch to absence value Momentar-action switch inputs Momentar-action switch 1 Momentar-action switch CH1 CH CH1 CH Displa of outputs controlled b momentaraction switch (CH1 and CH, or just CH1 or CH) Basic functions Switching on If the DGC module has been switched on via, lighting control is disabled. Switching off Dimming up Dimming down Profiles Profile 1: Individual room Profile : Classroom Profile : Corridor Profile : WC Profile 5: Free-standing luminaire (default profile) Profile Test: You ma use the Profile Test to check the profile ou selected. All times relevant to the profile are reduced to 15 s. The Profile Test will automaticall be terminated after 1 h, or b pressing the Auto ke of the DGC Programmer. The profiles can be adjusted to our needs via the mastercfigurator software or the DGC Programmer. For more detailed information please refer to the mastercfigurator documentation at www.tridonic.com. www.tridonic.com 1

luxctrol lighting control sstem Brief description of profiles Individual room profile CH1 CH SET Standb - 0% Onl - 0% Standb Onl CH1 CH 10min 10% 0min 10 min 1 min 10% 0min 1 min 10min 10% 1 min 10 min 1 min 1 min 10 min SET Classroom profile CH1 CH onl Corridor profile CH1 CH CH1 CH CH1 CH WC profile Free-standing luminaire profile (default) CH1 CH SET Standb CH1 CH SET www.tridonic.com 1